Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "mikrotomografia" wg kryterium: Temat


Tytuł:
A multistep approach for micro tomography obtained medical image segmentation
Autorzy:
Buczkowski, M.
Saeed, K.
Powiązania:
https://bibliotekanauki.pl/articles/332884.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
image segmentation
bilateral filter
Canny-Deriche edge detector
microtomography
porous materials
segmentacja obrazu
filtr dwustronny
wykrywanie krawędzi
mikrotomografia
materiały porowate
Opis:
This paper presents a multistep approach for segmentation of micro tomography images. Various images of porous structures were studied. Proper segmentation of that images is necessary to create 3D models of these structures. The introduced algorithm concerns finding the proper way of image filtering before the use of Canny-Deriche edge detection to obtain the best possible segmentation.
Źródło:
Journal of Medical Informatics & Technologies; 2014, 23; 69-76
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza mikro-CT zębów trzonowych wypełnianych kompozytem konwencjonalnym i wzmacnianym włóknem szklanym
Micro-CT analysis of molar teeth restored by combining conventional and glass fibre reinforced composites
Autorzy:
Surowska, B.
Ostapiuk, M.
Tarczydło, B.
Powiązania:
https://bibliotekanauki.pl/articles/284782.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
mikrotomografia komputerowa
wypełnienia kompozytowe
adhezja
struktura
computer micro-tomography
fillings
composite restoration
adhesion
structure
Opis:
Utrata tkanek zmineralizowanych zęba zarówno w efekcie procesów patologicznych, jak i samego leczenia jest czynnikiem decydującym o osłabieniu zęba. Najczęściej pojawiają się pęknięcia na powierzchni wypełnienia w następstwie powtarzających się cykli nagryzień. Rozprzestrzeniają się one wówczas w zębie i wypełnieniach. Pęknięcia obok mikroprzecieków są jednym z głównych powodów wymiany wypełnień. Ostatnio najczęściej wybieranymi, zarówno przez lekarzy stomatologów jak i pacjentów, materiałami odtwórczymi są materiały kompozytowe. Istnieje wiele sposobów zwiększania odporności mechanicznej kompozytów stomatologicznych np. umieszczanie ich w formie licowania na konstrukcjach metalowych lub wprowadzania do ich wnętrza różnego rodzaju włókien: szklanych, węglowych, poliaramidowych lub polietylenowych. Jednym z takich innowacyjnych materiałów jest everX Posterior firmy GC, kompozyt wzmocniony krótkim włóknem szklanym. Materiał ten posiada właściwości mechaniczne zbliżone do zębiny, używany jest do wypełnień ubytków w zębach bocznych jako pierwsza warstwa odtwarzająca zębinę. Zaawansowana nieniszcząca technika obrazowania struktur za pomocą tomografii komputerowej (CT) stanowi doskonałe narzędzie analizy jakości materiałów. Dlatego w prezentowanej pracy zastosowano technikę mikro-CT do analizy jakości wypełnienia i połączenia dwóch materiałów do odbudowy ubytków. W badaniu wykorzystano zęby trzonowe trzecie bez próchnicy usunięte ze względów ortodontycznych. Biomateriał kompozytowy wzmocniony włóknem szklanym everX Posterior firmy GC aplikowano jedną 2-3 mm warstwą, a następnie aplikowano kompozyt konwencjonalny Filtek Z250, 3M ESPE metodą warstwową 2-3 mm. Analizowana struktura zęba oraz materiałów kompozytowych potwierdza wysokiej jakości wypełnienia. Brak porowatości oraz szczeliny brzeżnej pozwala na wyeliminowanie mikro-przecieków pomiędzy wypełnieniami a tkanką zęba. Ponadto, granica rozdziału pomiędzy kompozytem wzmacnianym włóknami a kompozytem wzmacnianym nanocząstkami wydaje się doskonała.
The loss of mineralized tissues of the tooth as a result of pathogenic processes and treatment is the principal factor leading to tooth weakening. Most frequently, the cracks occur on the filling surface as a result of repeatable cycles of bites. They propagate in the tooth and the filling. The cracks belong to the reasons of filling's replacement and consequently affecting filling's durability. Recently, composite materials are most frequently selected by the dentists and patients as reconstruction materials. There are many ways of increasing mechanical resistance of dental composites e.g. their location in the form of facing on metal structures or introduction of various fibres made of glass, carbon, aramid or polyethy-lene. EverX Posterior is manufactured by GC in the form of composite reinforced with short glass fibres. The properties of this material are similar to the properties of dentine. Therefore it is used for cavity filling in side teeth as the first layer of dentine reconstruction. Advanced non-destructive structures imaging technique by means of computer tomography (CT) is an excellent tool used for materials quality analysis. So the micro-CT analysis of quality and joining of restorative materials based on different filler was presented in this paper. Third molars without caries, extracted due to orthodontic reasons, have been used in the test. Composite biomaterial reinforced with glass fibre - everX Posterior by GC – was applied in the form of single layer and next Filtek Z250, 3M ESPE conventional composite was applied in the form of layer with a thickness of 2-3 mm. Analysed structure of the tooth and composite materials confirms the high quality of the restoration. The filling received by layer technique is free of porosities, thus suggesting the lack of micro-leakages between the filling and tooth tissues. Moreover, the interface between the fibre reinforced and particle reinforced nanocomposite biomaterials seems to be ideal.
Źródło:
Engineering of Biomaterials; 2016, 19, 137; 13-19
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the X-ray micro-computed tomography to the analysis of the structure of polymeric materials
Zastosowanie mikrotomografii komputerowej do analizy struktury materiałów polimerowych
Autorzy:
Szewczykowski, Piotr P.
Skarżyński, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/947106.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
microstructure
non-destructive test
polymeric materials
X-ray micro-CT
mikrostruktura
badanie bezinwazyjne
materiały polimerowe
mikrotomografia komputerowa
Opis:
In this paper the application of X-ray micro-computed tomography (micro-CT) as a non-destructive testing method of polymeric materials is presented. Increasing applicability of polymers in variedend-use industries such as automotive, building and construction, consumer goods, and packaging is propelling the growth of the global polymer processing market. However, controlling of the polymer structure is one of the most important aspects since it affects mechanical properties of the components. The paper contains examples of two- and three-dimensional analysis of selected polymeric materials using of X-ray micro-computed tomography. Due to the complex structure of polymers, their shape and pores that are embedded inside the material and are not connected to the surface, the X-ray micro-computed tomography is an ideal solution for the analysis of the microstructure of polymeric materials to improve the process of their production in order to obtain components with the best possible properties.
Przedstawiono zastosowanie mikrotomografii komputerowej do bezinwazyjnej analizy struktury wewnętrznej materiałów polimerowych. Zwiększenie możliwości zastosowania polimerów w różnych branżach, takich jak: motoryzacja, budownictwo i opakowania, napędza rozwój światowego rynku przetwórstwa polimerów. Kontrola struktury materiałów, mającej ogromny wpływ na właściwości mechaniczne kompozytów polimerowych, jest bardzo istotna. Przedstawiona metoda mikrotomografii komputerowej, służąca ulepszeniu procesu wytwarzania komponentów o jak najkorzystniejszych właściwościach, jest idealnym narzędziem do analizy mikrostruktury materiałów polimerowych ze względu na ich złożoną budowę, kształt oraz liczbę porów zawartych w strukturze materiału (niestykających się z jego powierzchnią zewnętrzną). Podano przykłady dwu- i trójwymiarowej analizy mikrostruktury wybranych materiałów polimerowych z zastosowaniem mikrotomografii komputerowej.
Źródło:
Polimery; 2019, 64, 1; 12-22
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie 3D struktury przestrzeni porowej cementów metodą mikrotomografii rentgenowskiej (micro-CT)
Examination of internal pore space 3D images of cement rock with use of Roentgen Computed Tomography (Micro-CT)
Autorzy:
Dohnalik, M.
Zalewska, J.
Kut, Ł.
Kaczmarczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/349787.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
cement
struktura porowa kamieni cementowych
rozwój porowatości
mikrotomografia
cement rock pore structure
pore structure evolution
microtomography
Opis:
Metoda mikrotomografii rentgenowskiej (micro-CT) jest nieniszczącą metodą badawczą, która umożliwia wizualizację budowy wewnętrznej obiektów (w geologii np. skał i cementów). Metoda polega na rejestracji projekcji promieniowania X badanej próbki pod różnymi kątami, a następnie rekonstrukcji na tej podstawie struktury wewnętrznej próbki. Wizualizowanym parametrem jest współczynnik atenuacji liniowej, który zależy od energii promieniowania X, liczby atomowej pierwiastków budujących obiekt oraz gęstości badanej próbki. Micro-CT może być stosowana zarówno do jakościowej wizualizacji wewnętrznej struktury cementów, jak również do pozyskiwania danych ilościowych. Celem tego artykułu jest przedstawienie zastosowania mikrotomografii rentgenowskiej w badaniu cementów. W pracy zaprezentowano, po raz pierwszy w kraju, wyniki mikrotomograficznych badań mikrostruktury zaczynów cementowych w różnym wieku (1 do 28 dni). Wyniki pozwoliły przeanalizować zmiany w sieci porowej zaczynów podczas ich starzenia. Wykazano znaczące różnice w ewolucji porów pomiędzy próbami zaczynów o różnych składach. Wyniki te pokazują możliwości metody micro-CT w badaniu materiałów cementowych. Główną zaletą metody jest możliwość odtworzenia sieci porowej oraz prześledzenia zmian wielkości porów w czasie. Dzięki tej metodzie możliwe jest także badanie nowych cech, takich jak dystrybucja przestrzenna struktury porowej oraz określenie jej przewodności.
The X-ray computed microtomography (micro-CT) is a non-destrictive method for visualization of objects' internal structures (in geology - e.g. rocks or cement stones). Sample's X-ray projections at different angles are recorded and, on the basis of them, the objects' internal structure is reconstructed. Visualized parameter is the linear attenuation coefficient (proportional to X-ray's energy, material's density and atomic number of elements in object's structure). The micro-CT may be used to visualize the cement's internal structure and its quantitative analysis. The aim of this paper is to show application of micro-CT in cementary rocks examination. In this work the results of micro-CT measurement for cements of different age (1-28 days) are shown first time in Poland. Obtained results allowed to analyze changes of pore network during the cement rock's shrinking. Significant pore space evolution changes in case of cement rocks with different composition were observed. Results shown that micro-CT method is applicable for cement rocks examination. The main adventage of micro-CT is the ability to reconstruction of pore space and observation of its changes in time. Also the pores' spatial distribution and tortuosity may be examined.
Źródło:
Górnictwo i Geoinżynieria; 2010, 34, 4; 157-165
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka utworów czerwonego spągowca w aspekcie badań rentgenowskiej mikrotomografii komputerowej i mikroskopii optyczne
Characteristics of Rotliegend sediments in view of X-ray microtomohraphy and optical microscopy investigations
Autorzy:
Dohnalik, Marek
Ziemianin, Konrad
Powiązania:
https://bibliotekanauki.pl/articles/1833915.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
czerwony spągowiec
mikrotomografia
petrografia
własności zbiornikowe
Rotliegend
microtomography
petrography
reservoir properties
Opis:
The article presents the results of microtomographic and petrographic investigations of Rotliegend sandstones collected from core material from wells located in the area of the Fore-Sudetic Monocline in its central and northern parts and also on the border of the Fore-Sudetic Monocline and the Mogilno - Łódź Synclinorium. Three areas were selected for the study: Czarna Wieś–Parzęczewo (19 samples), Środa Wielkopolska–Kromolice (21 samples) and Siekierki–Miłosław (21 samples). The aim of the petrologic and microtomographic studies was to investigate how the different reservoir properties of sandstones will be reflected in the results of the methods used. Strong differences between samples from the region of Środa Wielkopolska–Kromolice and the other studied areas have been demonstrated. In the case of this area several key factors were noticed: the highest average value of effective porosity; the highest average content of pores belonging to class VII (pore volume subsystem classification); three times higher average value of the CT porosity coefficient and the largest length of the average chord. Also in terms of petrography (composition of grains, cement type) it is a region where major differences, especially compared to the region of Czarna Wieś–Parzęczewo, can be seen. Based on the obtained results, it was possible to rank the examined regions in terms of their reservoir properties – from the worst (Czarna Wieś–Parzęczewo) to the best (Środa Wielkopolska–Kromolice). These conclusions are also confirmed by other petrophysical analyses (eg. mercury porosimetry, permeability analysis). Combination of the obtained microtomographic and petrographic results allowed to obtain a full characterization of the investigated samples – both in terms of the mineralogical composition of grains, as well as the development of the pore space. These data, especially in combination with the results of density and porosity analyses (helium pycnometry and mercury porosimetry), open up a number of possibilities to carry out different types of modeling (porosity, permeability) both on the scale of the sample itself, as well as the scale of a single well or even the whole basin, which is crucial for creating a hydrocarbon exploration strategy.
Źródło:
Nafta-Gaz; 2020, 76, 11; 765--773
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakteryzacja geometryczna i mechaniczna skaffoldów ze stopu TI6AL7NB wytworzonych w technologii laserowej mikrometalurgii
Geometrical and mechanical characterization of scaffolds manufactured from TI-6AL-7NB by laser micrometallurgy – SLM
Autorzy:
Szymczyk, P.
Pawlak, A.
Ziółkowski, G.
Dybała, B.
Chlebus, E.
Powiązania:
https://bibliotekanauki.pl/articles/99269.pdf
Data publikacji:
2013
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
skaffold
Ti6Al7Nb
mikrotomografia komputerowa
SLM
scaffold
Ti-6Al-7Nb
computed microtomography
Opis:
Praca przedstawia wyniki badań struktur mikroskaffoldów wytwarzanych ze stopu Ti6Al7Nb, w technologii laserowej mikrometalurgii proszków metali. Opracowana technologia wytwarzania mikrostruktur kratowych, umożliwia produkowanie regularnie porowatych struktur, składających się z porów w kształcie sześcianu z walcowymi belkami wpisanymi w jego krawędzie. Celem badań było opracowanie metodologii oceny i charakteryzacji wytworzonych struktur.
This paper presents the investigation results on Ti6Al7Nb micro scaffold structures, manufactured in metal powder Selective Laser Melting process. Developed technology of manufacturing lattice microstructures, can produce regular porous structure consisting of pores in the shape of a cube with cylindrical beams entered in the edges. The aim of the study was to develop a methodology for the evaluation and characterization of the produced structures.
Źródło:
Aktualne Problemy Biomechaniki; 2013, 7; 157-162
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of surface modification by acetone vaporization on the structure of 3D printed acrylonitrile-butadiene-styrene elements
Wpływ waporyzacji acetonowej powierzchni elementów wykonanych techniką 3D z kopolimeru akrylonitryl-butadien-styren na ich strukturę
Autorzy:
Marciniak, D.
Szewczykowski, P.
Czyżewski, P.
Sykutera, D.
Bieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/945817.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
fused deposition modeling
microcomputer tomography
acetone vaporization
additive
manufacturing
mechanical properties
osadzanie topionego materiału
mikrotomografia komputerowa
waporyzacja acetonowa
technologie przyrostowe
właściwości mechaniczne
Opis:
The internal structure of samples produced by additive manufacturing (AM) technology of copolymer acrylonitrile-butadiene-styrene (ABS) was studied by microcomputer tomography (micro-CT). The results of micro-CT were correlated with the mechanical properties of samples. The aim of this paper was to demonstrate the acetone vaporization influence on the structure and mechanical properties of ABS samples printed with additive manufacturing technology. Samples were printed on three different devices and scanned with micro-CT after acetone vapors treatment. Mass and hardness of the samples were measured. Finally, the static tensile test was performed. Irregularly spaced voids, which directly affected samples properties, have been detected. Under the influence of acetone vaporization, the properties of the samples have changed such as: number of voids, mass, hardness, tensile strength.
Strukturę wewnętrzną próbek wykonanych metodą technologii przyrostowej z kopolimeru akrylonitryl-butadien-styren (ABS) zbadano za pomocą mikrotomografu komputerowego (CT). Wyniki skanów CT skorelowano z właściwościami mechanicznymi próbek. Oceniano wpływ oddziaływania par acetonu na strukturę i właściwości próbek z ABS wykonanych w technologii przyrostowej. Próbki przygotowano z zastosowaniem trzech różnych urządzeń i po waporyzacji acetonowej zeskanowano je za pomocą mikrotomografu. Wyznaczono masę, twardość oraz przeprowadzono statyczną próbę rozciągania próbek. W strukturze elementów z ABS stwierdzono obecność nieregularnie rozmieszczonych porów, wpływających na właściwości próbek. Pod wpływem waporyzacji acetonowej zmieniły się właściwości próbek, takie jak: liczba porów, masa, twardość oraz wytrzymałość na rozciąganie.
Źródło:
Polimery; 2018, 63, 11-12; 785-790
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heterogeneous pores distribution in polyurethane expanding foams detected via X-ray computed microtomography
Niejednorodność rozkładu porów w ekspandujących piankach poliuretanowych obserwowana metodą mikrotomografii komputerowej
Autorzy:
Blażejczyk, A.
Wierzbicka, P.
Powiązania:
https://bibliotekanauki.pl/articles/947301.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
rentgenowska mikrotomografia komputerowa
obrazowanie pianki
pianki poliuretanowe
pory
więzadła
X-ray computed microtomography
foam imaging
polyurethane foams
pores
struts
Opis:
X-ray computed microtomography (μ-CT) was applied as a noninvasive three-dimensional (3D) imaging technique for characterization of solid cellular material microstructure. Comparison between morphologies of two versions (summer and winter) of polyurethane (PUR) expanding foam (commercially available as the one-component 1K hand-held foams, applicable in building sector) was done. The evident relationship between processing and microstructure was explained. The most significant morphometric parameters were obtained via quantitative and qualitative 3D microstructure μ-CT analysis. The analysis embraced computing: dimensions of the selected structural elements (struts or pores), the average surface areas and volumes either of solid matrix or pores (open and close), as well as porosity assessment. The pores diameters (structure separation) statistical distributions were found and resulted as heterogeneous for both PUR versions, as revealed via proposed Gaussian μ-CT data analysis (“double Gauss” model).
Do charakterystyki mikrostruktury materiału komórkowego zastosowano rentgenowską mikrotomografię komputerową (µ-CT) – nieinwazyjną technikę obrazowania trójwymiarowego (3D). Porównano morfologie dwóch wersji (letniej i zimowej)pianki poliuretanowej (PUR), dostępnej w handlu w postaci jednoskładnikowej ekspandującej pianki typu 1K do zastosowań w budownictwie. Omówiono zaobserwowaną zależność między technologią przetwarzania a mikrostrukturą pianki. Na podstawie ilościowej i jakościowej mikrotomograficznej analizy trójwymiarowej mikrostruktury, obejmującej obliczenia wymiarów podstawowych elementów struktury (więzadeł i porów), a także powierzchni i objętości matrycy stałej i porów (otwartych i zamkniętych), wyznaczono najistotniejsze parametry morfometryczne. Dokonano też oceny porowatości pianki. Rozkłady średnic porów (structure separation) uzyskane w wyniku zaproponowanej gaussowskiej analizy danych mikrotomograficznych (double Gauss model) okazały się niejednorodne w wypadku obu wersji pianek PUR.
Źródło:
Polimery; 2018, 63, 10; 685-693
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of the carbonation zone in concrete using X-ray microtomography
Autorzy:
Łydżba, D.
Rajczakowska, M.
Stefaniuk, D.
Kmita, A.
Powiązania:
https://bibliotekanauki.pl/articles/178832.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
concrete
carbonation zone
X-ray microtomography
beton
strefa karbonatyzacji
mikrotomografia rentgenowska
Opis:
The article presents an application of X-ray microtomography for identification of the carbonation zone in concrete material. A concrete specimen subjected earlier to harsh environmental conditions is investigated. The material is firstly checked with the use of chemical corrosion indicators and then is subjected to microstructural analysis performed with the use of X-ray microtomography. Two different settings of scanning parameters are applied implying the image resolutions of approximately 14 μm per 1 pixel and about 7 μm per 1 pixel, respectively. The results obtained are then compared and analyzed. The depth of the carbonation zone is evaluated based on the attenuation curve. The paper highlights also the significance of the corrosion phenomenon in concrete structures. Details of the deterioration mechanisms in concrete are shortly presented.
Źródło:
Studia Geotechnica et Mechanica; 2014, 36, 1; 47-54
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interpretacja jakościowa i ilościowa przestrzeni porowej piaskowca karbońskiego na podstawie wyników rentgenowskiej tomografii komputerowej
Qualitative and quantitative interpretation of Carboniferous sandstone pore space on the basis of X-ray computed tomography results
Autorzy:
Gołda, P.
Krakowska, P.
Powiązania:
https://bibliotekanauki.pl/articles/1835253.pdf
Data publikacji:
2018
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
petrofizyka
rentgenowska mikrotomografia komputerowa
przestrzeń porowa
krętość kanałów porowych
porowatość całkowita
porowatość efektywna
petrophysics
computed microtomography
pore space
tortuosity
total porosity
effective porosity
Opis:
W pracy przedstawiono analizę przestrzeni porowej dwóch próbek karbońskich piaskowców kwarcowych z wykorzystaniem rentgenowskiej tomografii komputerowej (CT). Pierwszy etap prac stanowiło przetwarzanie obrazów CT. Przetwarzanie miało na celu poprawę stosunku sygnału do szumu oraz podniesienie rozpiętości tonalnej obrazów. Kolejnym etapem było stworzenie obrazu zbinaryzowanego. Następnie na podstawie przekrojów 2D i obrazu 3D dokonano interpretacji jakościowej i ilościowej przestrzeni porowej. Interpretacja jakościowa polegała na porównaniu uzyskanych podgrup sieci porowej między sobą, jak też między próbkami. Wyliczono porowatość całkowitą oraz zmiany porowatości w kolejnych przekrojach CT. Dane posłużyły również do analizy pola powierzchni porów oraz do policzenia charakterystyki Eulera. Obiekt charakteryzujący się największą objętością został użyty do obliczenia porowatości efektywnej, długości sieci porowej, liczby gałęzi i skrzyżowań, krętości kanału porowego. Uzyskana porowatość całkowita była zbliżona do obliczonej z wykorzystaniem innych metod laboratoryjnych. Policzono też liczbę porów przypadającą na każdy przekrój oraz średni rozmiar porów na przekrój CT. Dokonano podziału przestrzeni porowej próbek na klasy powierzchni, obliczono liczbę porów przyporządkowanych do danej klasy oraz ich procentowy udział w budowaniu całej przestrzeni porowej. Dla sieci porów odizolowanych dokonano podziału na klasy objętości, następnie stwierdzono liczbę elementów w danej klasie oraz jej procentowy udział. Próbka nr 1 wykazała heterogeniczność w wykształceniu przestrzeni porowej, cechowała się większą liczbą porów, lepszą jakością połączeń struktury porowej oraz miała więcej porów o mniejszych objętościach. Średni rozmiar porów próbki nr 2 był większy. Przestrzeń porową próbki nr 2 tworzyły pory o większej powierzchni. Obliczona krętość kanału porowego wynosiła 2,17. Micro-CT okazało się dobrym narzędziem do szczegółowej analizy budowy przestrzeni porowej skał.
The paper presents an analysis of the pore space of two Carboniferous quartz sandstone samples using X-ray computed tomography (CT). The first stage of the work was the processing of CT images. The processing was aimed at improving the signal-to-noise ratio and increasing the tonal range of images. The next stage was to create a binary image. Next, a qualitative and quantitative interpretation of the pore space was made on the basis of 2D sections and 3D images. The qualitative interpretation consisted in comparing the obtained pore network subgroups with each other and between samples. The total porosity and changes in porosity in subsequent CT cross-sections were calculated. The data also served to analyze the pore surface area and to calculate the Euler’s characteristics. The object with the largest volume was used to calculate the effective porosity, the length of the pore network, the number of branches and intersections, and the tortuosity of the pore channel. The obtained total porosity was similar to that calculated using other laboratory methods. The number of pores per each cross-section and the average pore size per CT section were also counted. The pore space of samples was divided into surface classes. The number of pores assigned to a given class was calculated as well as their percentage share in building the entire pore space. For the network of isolated pores, the division into volume classes was made, then the number of elements in a given class and its percentage share were counted. Sample no. 1 showed heterogeneity in the development of pore space, was characterized by more pores, better quality of pore structure connections and had more pores with smaller volumes. The average pore size of sample no. 2 was larger. The pore space of sample no. 2 was made up of pores with a larger surface area. The calculated tortuosity of the pore channel was 2.17. Micro-CT proved to be a good tool for a detailed analysis of the structure of the rocks pore space.
Źródło:
Nafta-Gaz; 2018, 74, 7; 487-494
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda pomiaru gęstości osadu pokoagulacyjnego z zastosowaniem tomografii rentgenowskiej
Measurement method of sediment densities after coagulation using x-ray tomography
Autorzy:
Rząsa, M. R.
Podgórni, E.
Powiązania:
https://bibliotekanauki.pl/articles/268323.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
gęstość osadu
koagulacja
mikrotomografia rentgenowska
density of sediment
coagulation
X-ray microtomography
Opis:
Koagulacja jest jednym z procesów oczyszczania wody. Polega na destabilizacji układu koloidalnego i aglomeracji cząstek, które następnie usuwa się w procesach sedymentacji, flotacji czy filtracji. Powstałe cząstki pokoagulacyjne charakteryzują się zróżnicowanym kształtem, wielkością oraz strukturą. Szybkość opadania takich cząstek w dużej mierze zależy od ich gęstości. Struktura cząstek powoduje, że wyróżnia się dwa rodzaje porów. Makropory, które nie powinny być uwzględniane przy wyznaczaniu gęstości oraz mikropory, które stanowią cechę charakteryzującą dany osad pokoagulacyjny. Gęstość wyznaczono metodą wagową dla odpowiednio przygotowanych próbek. Ponieważ proces prasowania może niszczyć mikrostrukturę osadu, przeprowadzono badania mające na celu określenie stopnia sprasowania próbek, aby zminimalizować błędy wyznaczenia gęstości. Badania te prowadzono za pomocą tomografu rentgenowskiego, dzięki któremu możliwe było wyznaczenie objętości danej próbki z korektą makroporowatości. W pracy przedstawiono wyniki badań oraz parametry graniczne procesu przygotowywania próbek.
Coagulation is one of the processes of water purification, which consists in the destabilization of the dispersion and agglomeration of the particles, which are removed in the process of sedimentation, flotation or filtration. After the coagulation particles have a varied shape, size and porous structure. The rate of descent of such particles largely depends on their density. The structure of the particles causes two types of pores. Macropores that should not be taken into account when determining the density, and micropores, which are a characteristic feature of the sediment after coagulation process. To determine the density of sludge samples were subjected to compression, in order to eliminate the macropores and then, after designation of sample volume, density was determined by weighing. The precipitate was prepared based on a prepared water model, to which was added a coagulant Flokor 1.2A. The precipitate was filtered on a cellulose filter, and then subjected to a drying process. The dry sludge was pressed on the press impact. Because of the pressing process can destroy the microstructure of the sediment, studies have been conducted to determine the degree of compression of samples to minimize errors while determine the density. These studies were carried out using X-ray tomography, it was possible to designate the volume of the sample while subtraction residues macropores. For the correct determination of the volume, determination the correct number of threshold is necessary, based on which is possible to qualify individual pixels. In order to clearly identify which pixels represent sediment, it was necessary to carry out the image processing. That process were performed using LabVIEW software and Vision module. The paper presents results of research for density measurement and sets limits for the sample preparation process.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 159-162
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrotomografia komputerowa w służbie inżynierii drogowej
Computer microtomography in the service of road engineering
Autorzy:
Mączka, Eryk
Powiązania:
https://bibliotekanauki.pl/articles/129056.pdf
Data publikacji:
2020
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
mikrotomografia komputerowa
inżynieria drogowa
zastosowanie
badanie strukturalne
materiał drogowy
metodologia badania
porowatość
computer microtomography
road engineering
application
structural study
road material
research methodology
porosity
Opis:
W artykule o charakterze przeglądowym zaprezentowano potencjał mikrotomografii komputerowej, która może zostać zastosowana do badań i analiz strukturalnych materiałów drogowych takich jak mieszanki mineralno-asfaltowe. Praca zawiera opis metodologii badania z użyciem mikrotomografu komputerowego przeznaczonego do dokładnych badań materiałowych. Zaprezentowano ocenę strukturalną materiału, analizę porowatości oraz wykorzystanie obrazowania tomograficznego do oceny mechanistyczno-wytrzymałościowego materiału. Na przykładzie nowatorskiej analizy agresji chemicznej wywołanej agresją chlorkową przedstawiono dodatkowe możliwości techniczne urządzenia. Artykuł kończy podsumowanie opisanych zastosowań tej metody badawczej w stosunku do mieszanek mineralno-asfaltowych. Wskazano na zalety i możliwości wprowadzenia mikrotomografii do powszechnego użycia w drogowej inżynierii lądowej.
The article shows the potential of computer microtomography that can be used for research and structural analysis of road materials such as asphalt mixtures. The work contains a description of the research methodology using a computer microtomograph on the example of asphalt concrete. The paper discusses the structural assessment of the material, porosity analysis, the use of tomographic imaging to assess the mechanics and strength of the material, and presents a novelty in the form of an analysis of chemical aggression caused by chloride aggression. The article ends with a summary of the applications of this research methodology in relation to asphalt mixtures and indicates the advantages and possibilities of introducing microtomography for widespread use in road engineering.
Źródło:
Builder; 2020, 24, 5; 28-32
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of the tension and compression behavior of sintered 316L using micro computed tomography
Autorzy:
Doroszko, M.
Seweryn, A.
Powiązania:
https://bibliotekanauki.pl/articles/387023.pdf
Data publikacji:
2015
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
finite element method
X-ray microtomography
porous materials
mechanical properties
plasticity
metoda elementów skończonych (MES)
mikrotomografia rentgenowska
materiały porowate
plastyczność
właściwości mechaniczne
Opis:
This paper describes the method of numerical modeling of the tension and compression behavior of sintered 316L. In order to take into account the shape of the mesostructures of materials in the numerical modeling, X-ray microtomography was used. Based on the micro-CT images, three-dimensional geometrical models mapped shapes of the porosity were generated. To the numerical calculations was used finite element method. Based on the received stress and strain fields was described the mechanism of deformation of the materials until fracture. The influence of material discontinuities at the mesoscopic scale on macromechanical properties of the porous materials was investigated.
Źródło:
Acta Mechanica et Automatica; 2015, 9, 2; 70-74
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of X-ray propagation in bone microstructure
Autorzy:
Binkowski, M.
Król, Z.
Wróbel, Z.
Zeilhofer, H.-F.
Powiązania:
https://bibliotekanauki.pl/articles/333863.pdf
Data publikacji:
2005
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
mikrotomografia
mikrostruktury kości
tłumienie promieniowania rentgenowskiego
wizualizacja
tomografia komputerowa
erozja
microtomography
X-ray propagation
bone microstructure
attenuation of X-ray radiation
visualization
computed tomography
erosion
Opis:
This paper presents some results concerning the analysis of X-ray propagation through biological structures. We introduce a physical model of the phenomenon and a numerical method based on this model for simulation of X-ray radiation propagation. The proposed method enables generation of radiological projections like those in the computed tomography or microtomography. We have focused our attention on the attenuation of X-ray radiation in bone tissue. Our computational model enables simulation of radiation propagation in the virtual specimen. The virtual bone microstructures used in our experiments are derived from the microtomography datasets of real bone specimens. The main advantage of our approach is that we can change the microstructure of the virtual sample in many ways by using the image processing methods. Results presented in this paper contain simulations of X-ray propagation for modified and unmodified trabecular microstructures as well as the visualization of the radiation intensity distribution for the simulated cases. With this new simulation technique, it is possible for example to analyze the propagation of X-ray radiation for different pathologic types of bone microstructure (e.g. virtually generated osteoporosis).
Źródło:
Journal of Medical Informatics & Technologies; 2005, 9; 75-82
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Morphology and surface topography of Ti6Al4V lattice structure fabricated by selective laser sintering
Autorzy:
Maszybrocka, J.
Stwora, A.
Gapiński, B.
Skrabalak, G.
Karolus, M.
Powiązania:
https://bibliotekanauki.pl/articles/202149.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
metal porous implant
selective laser sintering
surface roughness
X-ray microtomography
selektywne spiekanie laserowe
chropowatość powierzchni
Mikrotomografia
Opis:
Construction of metallic implants with a porous structure that mimics the biomechanical properties of bone is one of the challenges of orthopedic regenerative medicine. The selective laser sintering technique (SLS) allows the production of complex geometries based on three-dimensional model, which offers the prospect of preparing porous metal implants, in which stiffness and porosity can be precisely adjusted to the individual needs of the patient. This requires an interdisciplinary approach to design, manufacturing and testing of porous structures manufactured by selective sintering. An important link in this process is the ability to assess the surface topography of the struts of porous structure. The paper presents a qualitative assessment of the surface morphology based on SEM studies and methodology that allows for quantitative assessment of stereometric structure based on micro-tomographic measurements.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 1; 85-92
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies