Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "mikroskopia sil atomowych" wg kryterium: Temat


Tytuł:
A Comparison between Contact and Tapping AFM Mode in Surface Morphology Studies
Autorzy:
Bramowicz, M.
Kulesza, S.
Rychlik, K.
Powiązania:
https://bibliotekanauki.pl/articles/298112.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
mikroskopia sił atomowych
AFM
topografia powierzchni
atomic force microscopy (AFM)
surface topography
Opis:
The paper presents recent results from studies of a surface topography of a platinum calibration grid on silicon substrate obtained in both contact and tapping modes of the AFM microscope. The results are analyzed in order to determine the influence of the scan set-up and the SPM probe onto estimated fractal parameters and surface anisotropy ratio.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2012, 15(2); 307-318
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka nanostrukturalna materiału genetycznego do zastosowania w terapii genowej
Nanostructural characteristics of genetic material for gene therapy application
Autorzy:
Duda, M.
Frączkowska, K.
Przybyło, M.
Kopaczyńska, M.
Powiązania:
https://bibliotekanauki.pl/articles/261139.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
kondensacja DNA
spermidyna
terapia genowa
mikroskopia sił atomowych
DNA condensation
spermidine
gene therapy
atomic force microscopy (AFM)
Opis:
Terapia genowa jest obecnie bardzo dynamicznie rozwijającą się techniką biomedyczną, która może znaleźć zastosowanie w medycynie w leczeniu chorób przewlekłych i dziedzicznych. Badania skupiają się na opracowywaniu nowych strategii dotyczących procesów kondensacji i ochrony materiału genetycznego (DNA) wprowadzanego do komórki docelowej. Struktura i stopień upakowania dostarczanego DNA wpływają na kluczowe właściwości fizykochemiczne, determinujące czy wprowadzony wektor rekombinowany ulegnie ekspresji, czy też degradacji. Związki chemiczne, zwane czynnikami kondensującymi, to substancje powodujące zwinięcie DNA, a stopień kondensacji materiału genetycznego zależy bezpośrednio od rodzaju i stężenia użytego czynnika kondensującego. Do cząsteczek wykazujących właściwości kondensujące należą poliaminy, w opisywanym eksperymencie zastosowano poliaminę – spermidynę. Przeprowadzone badania miały na celu charakterystykę nanostrukturalną materiału genetycznego pod wpływem działania czynnika kondensującego. W wyniku analizy wykonanej za pomocą mikroskopii sił atomowych (AFM) wykazano, że plazmid DNA ulega kondensacji pod wpływem spermidyny, formując struktury rozetowe.
Gene therapy is a new promising method that may find many applications in modern biomedicine. Especially, it may be a powerful tool in chronic and hereditary diseases treatment. Current studies focus on development of novel strategies concerning genetic material (DNA) condensation and protection, whilst it is introduced into the cellular nucleus. Once the DNA enters the cell, it’s either passed on and expressed in the nucleus or degraded by intracellular nucleases. The structure and the degree of compaction influence physicochemical properties that determine what will happen to delivered genetic material. DNA coiling can be caused by chemical compounds called compaction agents, such as polyamines like spermidine used in this study. The aim of this research was to examine the nanostructural characteristics of genetic material exposed to compaction agent. The measurements and analysis performed by atomic force microscopy (AFM) indicate that DNA plasmid undergoes condensation and forms rosette-like structures once subjected to spermidine.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2015, 21, 1; 1-8
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
TEM & AFM - Complementary Techniques for Structural Characterization of Nanobainitic Steel
TEM & AFM – komplementarne techniki charakteryzacji struktury nanobainitycznej
Autorzy:
Dworecka, J.
Jezierska, E.
Rębiś, J.
Rożniatowski, K.
Świątnicki, W.
Powiązania:
https://bibliotekanauki.pl/articles/353216.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
transmission electron microscopy TEM
atomic force microscopy (AFM)
nanobainite
bearing steel
elektronowy mikroskop transmisyjny (TEM)
mikroskopia sił atomowych (AFM)
struktura nanobainityczna
stalowe łożyska
Opis:
The aim of this study was to analyse and to identify the phases which formed in 100CrMnSi6-4 bearing steel after the nanostructuring heat treatment. Especially designed thermal treatment parameters were applied in order to obtain a nanobainitic structure. Two different microscopic techniques were used for the precise examination of the microstructures obtained: transmission electron microscopy (TEM) and atomic force microscopy (AFM). Both analyses confirm that the examined steel has a nanocrystalline structure. However, it was discovered that the selected analysis methods affected the results of the plate thickness measurements.
Celem pracy była analiza struktury i identyfikacja faz powstałych podczas procesu nanostrukturyzacji stali łożyskowej 100CrMnSi6-4. Chcąc wytworzyć strukturę nanobainityczną przeprowadzono obróbkę cieplną o specjalnie dobranych parametrach. Następnie wykonano precyzyjną analizę otrzymanej mikrostruktury wykorzystując w tym celu dwie zaawansowane techniki mikroskopowe: transmisyjną mikroskopię elektronową (TEM) oraz mikroskopię sił atomowych (AFM). Badania wykonane obiema technikami potwierdziły, że badano stal o strukturze nanobainitycznej. Wykazano też, że zależnie od zastosowanej techniki badawczej otrzymano różnice w wartościach zmierzonych grubościach elementów struktury.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3A; 1591-1593
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Description of Surface Topography of Metal Matrix Composite Castings
Autorzy:
Gawdzińska, K.
Bryll, K.
Gucma, M.
Pijanowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/382957.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
metal matrix composites
surface topography
profilography
confocal microscopy
atomic force microscopy (AFM)
kompozyty metalowe
topografia powierzchni
profilograf
mikroskopia konfokalna
mikroskopia sił atomowych
Opis:
The paper presents studies of topography of the metal matrix composite castings using profilography, confocal microscopy and atomic force microscopy. The examined materials were composites from the ex-situ group, manufactured by the saturation of reinforcement (aluminosilicate or carbon) with the liquid aluminum alloy (AlSi9 or AlSi11). The materials were observed on the various surface state, resulting from different stages of preparation of the polished section for the metallographic between the composite matrix and reinforcement.
Źródło:
Archives of Foundry Engineering; 2014, 14, 1 spec.; 169-174
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aging of carbon nanotube-filled fluoroelastomer in oil-based drilling fluid
Starzenie fluoroelastomeru napełnionego nanorurkami węglowymi w płuczce wiertniczej na bazie oleju
Autorzy:
Heidarian, J.
Powiązania:
https://bibliotekanauki.pl/articles/1205317.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
carbon nanotube
fluoroelastomer
carbon black
oil-based drilling mud
aging test
atomic force microscopy
optical microscopy
nanorurki węglowe
sadza węglowa
płuczka wiertnicza
test starzeniowy
mikroskopia sił atomowych
mikroskopia optyczna
Opis:
Carbon nanotube (CNT)-, carbon black (CB)-filled fluoroelastomer (FE) and unfilled FE compounds were prepared (CNT/FE, CB/FE and FE). The oil-based drilling mud (OBD) aging resistance of these elastomers were assessed by tests of atomic force microscopy (AFM), optical microscopy and X-ray diffractometry (XRD). Weight gain, swelling and hardness were also determined. The whole conclusion is that CNT/FE can be used as O-rings in OBD drilling while FE and CB/FE can not.
Metodami mikroskopii optycznej, mikroskopii sił atomowych (AFM) i dyfraktometrii rentgenowskiej (XRD) badano odporność starzeniową kompozytów na bazie fluoroelastomeru (FE) napełnianego nanorurkami węglowymi (CNT) lub sadzą węglową (CB), poddanych działaniu płuczki wiertniczej na bazie oleju (OBD). Oznaczano też przyrost masy, stopień spęcznienia i twardość próbek poddanych starzeniu w środowisku płynu wiertniczego. Stwierdzono, że fluoroelastomer napełniony nanorurkami węglowymi jest odporny na działanie płynu wiertniczego i można go stosować w materiale uszczelek w urządzeniach wiertniczych wykorzystujących płuczki na bazie oleju.
Źródło:
Polimery; 2018, 63, 3; 191-212
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza polimerowych membran nanofiltracyjnych za pomocą nowoczesnych technik badawczych
Analysis of polymeric nanofiltration membranes by modern techniques
Autorzy:
Kowalik-Klimczak, A.
Bednarska, A.
Grądkowski, M.
Gierycz, P.
Powiązania:
https://bibliotekanauki.pl/articles/947443.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
polimerowe membrany nanofiltracyjne
analiza powierzchni
potencjał zeta
skaningowa mikroskopia elektronowa
mikroskopia sił atomowych
rentgenowska spektroskopia fotoelektronowa
nanofiltration polymeric membranes
surface modern research techniques
zeta potential
scanning electron microscopy
atomic force microscopy (AFM)
X-ray photoelectron spectroscopy
Opis:
Za pomocą nowoczesnych technik analizy powierzchni, takich jak: pomiary potencjału zeta, skaningowa mikroskopia elektronowa, mikroskopia sił atomowych oraz rentgenowska spektroskopia fotoelektronów, zbadano dwa rodzaje membran polimerowych przeznaczonych do nanofiltracji. Stwierdzono, że ww. techniki analityczne umożliwiają komplementarne określenie właściwości fizykochemicznych powierzchni polimerowych membran nanofiltracyjnych, a tym samym ułatwiają dobór membrany do określonego zastosowania.
In the paper, two types of nanofiltration polymeric membranes are examined using modern techniques including zeta potential measurement, scanning electron microscopy, atomic force microscopy and X-ray photoelectron spectroscopy. The authors argue that the presented techniques are suitable for the complementary determination of physicochemical properties of polymeric nanofiltration membranes and consequently give information necessary for the proper selection of amembrane for a particular application.
Źródło:
Polimery; 2016, 61, 5; 339-346
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the possibilities of using atomic force microscopy (AFM) for characterisation of polymeric nanofiltration membrane surfaces
Ocena możliwości wykorzystania mikroskopu sił atomowych w badaniach powierzchni polimerowych membran nanofiltracyjnych
Autorzy:
Kowalik-Klimczak, A.
Gierycz, P.
Powiązania:
https://bibliotekanauki.pl/articles/257281.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
atomic force microscopy (AFM)
nanofiltration
polymeric membranes
surface roughness
mikroskopia sił atomowych
nanofiltracja
membrany polimerowe
chropowatość powierzchni
Opis:
In this study, the possibility of using an atomic force microscopy to analyse the surface structure of the polymeric nanofiltration membranes was investigated. Analysis of the obtained results allowed one to conclude that the size of the scanned surface directly affects the measurement result of both the average and root-mean-square roughness of tested membranes. Therefore, it is necessary to compare the results obtained for the same size of the scanned surface.
W pracy zbadano możliwość zastosowania mikroskopu sił atomowych do analizy struktury powierzchni polimerowych membran nanofiltracyjnych. Analiza uzyskanych wyników pozwoliła na stwierdzenie, że wielkość skanowanej powierzchni bezpośrednio wpływa na wynik pomiaru zarówno chropowatości średniej arytmetycznej, jak i kwadratowej testowanych membran. Konieczne jest zatem porównywanie wyników uzyskanych dla takich samych wielkości skanowanej powierzchni.
Źródło:
Problemy Eksploatacji; 2014, 3; 17-25
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody badań mikroświata
Autorzy:
Kucia, M.
Powiązania:
https://bibliotekanauki.pl/articles/847740.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Przyrodników im. Kopernika
Tematy:
metody badan
obrazowanie
mikroskopia
mikroskopia optyczna
mikroskop optyczny
ultramikroskop
mikroskop ciemnego pola
mikroskop jasnego pola
mikroskop polaryzacyjny
mikroskop polaryzacyjno-interferencyjny
mikroskopia fluorescencyjna
mikroskop fluorescencyjny
mikroskopia konfokalna
mikroskop konfokalny
mikroskopia elektronowa
mikroskop elektronowy
mikroskopia sil atomowych
mikroskop sil atomowych
Źródło:
Wszechświat; 2013, 114, 10-12
0043-9592
Pojawia się w:
Wszechświat
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New thermoplastic poly(carbonate-urethane) elastomers
Autorzy:
Kultys, A.
Rogulska, M.
Powiązania:
https://bibliotekanauki.pl/articles/779306.pdf
Data publikacji:
2011
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
elastomery termoplastyczne
elastomery poliuretanowe
diole
diizocyjanian 4,4'-difenylometanu
diizocyjanian heksano-1,6-diylu
właściwości termiczne
właściwości mechaniczne
mikroskopia sił atomowych
thermoplastic polyurethane elastomers
poly(hexane-1,6-diyl carbonate) diol
4,4'-diphenylmethane diisocyanate
thermal properties
mechanical properties
atomic force microscopy (AFM)
Opis:
Two series of novel thermoplastic poly(carbonate-urethane) elastomers, with different hard-segment content (30 - 60 wt %), were synthesized by melt polymerization from poly(hexane-1,6-diyl carbonate) diol of Mn = 2000 as a soft segment, 4,4'-diphenylmethane diisocyanate (MDI) or hexane-1,6-diyl diisocyanate (HDI) and 6,6'-[methylenebis(1,4-phenylenemethylenethio)]dihexan-1-ol as a chain extender. The structure and basic properties of the polymers were examined by Fourier transform infrared spectroscopy, X-ray diffraction analysis, atomic force microscopy, differential scanning calorimetry, thermogravimetric analysis, Shore hardness and tensile tests. The resulting TPUs were colorless polymers, showing almost amorphous structures. The MDI-based TPUs showed higher tensile strengths (up to 21.3 MPa vs. 15.8 MPa) and elongations at break (up to 550% vs. 425%), but poorer low-temperature properties than the HDI-based analogs.
Źródło:
Polish Journal of Chemical Technology; 2011, 13, 1; 23-30
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected imaging techniques applied in forensic science
Wybrane techniki obrazowania stosowane w kryminalistyce
Autorzy:
Łasińska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/501727.pdf
Data publikacji:
2018-03-15
Wydawca:
Agencja Bezpieczeństwa Wewnętrznego
Tematy:
imaging techniques
microscopy
SEM
X-ray microanalysis
EDS
Raman spectroscopy
atomic force microscopy
AFM
techniki obrazowania
mikroskopia
mikroanaliza rentgenowska
spektroskopia Ramana
mikroskopia sił atomowych
Opis:
The article presents issues that include various imaging techniques used in forensics. Technology development observed in the modern world, implies changes in all areas of life, improving, speeding up and opening them to new research capabilities. The use of advanced technology allows precise analysis of the evidence. The opportunity to observe different samples at high magnification is necessary in the performance of their documentation (examination of the morphology of the surface, setting the diagnostic characteristics). The application of optical microscopy, electron microscopy or atomic force microscopy, and integrated spectroscopic systems is an essential and powerful tool for implementation observations of a variety of materials.
W artykule przedstawiono zagadnienia obejmujące różne techniki obrazowania wykorzystywane w kryminalistyce. Rozwój technologii obserwowany we współczesnym świecie pociąga za sobą zmiany we wszystkich dziedzinach życia, usprawniając, przyspieszając oraz otwierając je na nowe możliwości badawcze. Wykorzystanie zaawansowanej technologii pozwala na precyzyjną analizę materiału dowodowego. Możliwość obserwacji różnych próbek w dużych powiększeniach jest niezbędna przy wykonywaniu ich dokumentacji (badanie morfologii powierzchni, ustalanie cech diagnostycznych). Zastosowanie mikroskopii optycznej, elektronowej lub sił atomowych, a także zintegrowanych z nimi systemów spektroskopowych jest podstawowym, a zarazem potężnym narzędziem służącym wykonywaniu obserwacji różnorodnych materiałów.
Źródło:
Przegląd Bezpieczeństwa Wewnętrznego; 2018, 10, 18; 283-309
2080-1335
2720-0841
Pojawia się w:
Przegląd Bezpieczeństwa Wewnętrznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane techniki obrazowania stosowane w kryminalistyce.
Selected imaging techniques applied in forensic science
Autorzy:
Łasińska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/501703.pdf
Data publikacji:
2018-03-15
Wydawca:
Agencja Bezpieczeństwa Wewnętrznego
Tematy:
techniki obrazowania
mikroskopia
SEM
mikroanaliza rentgenowska
EDS
spektroskopia Ramana
mikroskopia sił atomowych
AFM
imaging techniques
microscopy
X-ray microanalysis
Raman spectroscopy
atomic force microscopy
Opis:
W artykule przedstawiono zagadnienia obejmujące różne techniki obrazowania wykorzystywane w kryminalistyce. Rozwój technologii obserwowany we współczesnym świecie pociąga za sobą zmiany we wszystkich dziedzinach życia, usprawniając, przyspieszając oraz otwierając je na nowe możliwości badawcze. Wykorzystanie zaawansowanej technologii pozwala na precyzyjną analizę materiału dowodowego. Możliwość obserwacji różnych próbek w dużych powiększeniach jest niezbędna przy wykonywaniu ich dokumentacji (badanie morfologii powierzchni, ustalanie cech diagnostycznych). Zastosowanie mikroskopii optycznej, elektronowej lub sił atomowych, a także zintegrowanych z nimi systemów spektroskopowych jest podstawowym, a zarazem potężnym narzędziem służącym wykonywaniu obserwacji różnorodnych materiałów.
The article presents issues that include various imaging techniques used in forensics. Technology development observed in the modern world, implies changes in all areas of life, improving, speeding up and opening them to new research capabilities. The use of advanced technology allows precise analysis of the evidence. The opportunity to observe different samples at high magnification is necessary in the performance of their documentation (examination of the morphology of the surface, setting the diagnostic characteristics). The application of optical microscopy, electron microscopy or atomic force microscopy, and integrated spectroscopic systems is an essential and powerful tool for implementation observations of a variety of materials.
Źródło:
Przegląd Bezpieczeństwa Wewnętrznego; 2018, 10, 18; 89-119
2080-1335
2720-0841
Pojawia się w:
Przegląd Bezpieczeństwa Wewnętrznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania doświadczalne zużycia główki endoprotezy stawu biodrowego ze stopu kobalt-chrom oraz z tlenku aluminium
An experimental study of the nano-scratch behavior of a femoral head
Autorzy:
Leshchynsky, V.
Soifer, Y.
Wierusz-Kozłowska, M.
Markuszewski, J.
Woźniak, W.
Bielousova, O.
Weinert, H.
Powiązania:
https://bibliotekanauki.pl/articles/211696.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Obróbki Plastycznej
Tematy:
endoprotezy stawu biodrowego
mechanizm zużycia
topografia powierzchni
mikroskopia sił atomowych
hip replacement prosthesis
wear mechanism
surface topography
atomic force microscopy (AFM)
Opis:
Artykuł dotyczy badań doświadczalnych zużycia główek endoprotez stawu biodrowego wykonanych w ramach zakresu badań na symulatorach ruchu endoprotez kolanowych i biodrowych prowadzonych w Instytucie Obróbki Plastycznej w Poznaniu we współpracy z Katedrą i kliniką Ortopedii i Traumatologii Uniwersytetu Medycznego w Poznaniu z udziałem Uniwersytetu Tel Aviv. Zużycie wciąż jest znaczącym czynnikiem wpływającym na uszkodzenia implantów. Badania in-vivo wykazują, że na większe zużycie wpływa chropowatość powierzchni protez główki kości udowej. W przypadku endoprotezy stawu biodrowego z wkładką z polietylenu, zuzycie bardziej miękkiego polietylenu jest powodowane chropowatością powierzchni główki, która niszczy powierzchnię polietylenu i odłącza jego cząstki. W artykule opisano wyniki badań morfologii powierzchni główki implantu po eksploatacji oraz wyniki modelowania procesu uszkodzenia tej powierzchni poprzez nanoindentację i nanozarysowania celem lepszego zrozumienia mechanizmu procesu zużywania się endoprotezy stawu biodrowego. Badania przeprowadzono metodą mikroskopii sił atomowych (AFM). Badania wykazały poważne uszkodzenia powierzchni kobaltowo – chromowej i ceramicznej główki. Stwierdzono, ze zarysowania na główce kości udowej w nanoskali powstają w wyniku formowania się bryłowatych wypukłości o niskiej gęstości, które mogą działać jako inicjatory powstawania produktów zużycia, co wydaje się być jedną z głównych przyczyn zużycia polietylenu w pierwszym etapie eksploatacji implantu stawu biodrowego.
Bearing wear continues to be a contributing factor to implant failure. Prosthetic femoral heads roughen in vivo which leads to increased wear. For a femoral head articulating against polyethylene, wear of softer polyethylene is known to be caused by the hard asperities on the surface of the femoral head, that destroy polyethylene surface and detach polyethylene particles. In the present work in order to better understand the mechanism of femoral head prosthesis wear process we studied the femoral head surface morphology after implant articulation and modeled the damage of the femoral head surface by nanoindentation and nanoscratching with Atomic Force Microscopy Technique. The Atomic Force Microscopy examination of scratching process revealed a severe surface damage cobalt-chrome and alumina femoral head surface. The nano-scale scratch of femoral heads is shown to result in formation of lumpy protuberances with low density which can act as a precursor for wear particles that seems to be one of the main reasons of polyethylene wear at least at the first (running) stage of the HIP implant articulation.
Źródło:
Obróbka Plastyczna Metali; 2009, 20, 4; 30-42
0867-2628
Pojawia się w:
Obróbka Plastyczna Metali
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Short Review : Probing Mechanical Properties of Individual Molecules with Atomic Force Spectroscopy
Krótki artykuł przeglądowy : badania mechanicznych właściwości pojedynczych cząsteczek przy pomocy spektroskopii sił atomowych
Autorzy:
Marszałek, P. E.
Powiązania:
https://bibliotekanauki.pl/articles/159965.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
Mikroskopia Sił Atomowych
Spektroskopia siłowa pojedynczych cząsteczek
biopolimery
nanomechanika
Atomic Force Microscopy
Single Molecule Force Spectroscopy
Nanomechanics
Polymer elasticity
Biopolymers
Opis:
W niniejszym krótkim artykule przeglądowym, na początku zwięźle opiszę zasady spektroskopii siłowej do badania mechanicznych właściwości pojedynczych cząsteczek przy użyciu mikroskopu sił atomowych. Następnie, omówię najważniejsze, moim zdaniem, odkrycia i obserwacje w tej tematyce, która rozwija się niezwykle dynamicznie przez ostatnie ponad 25 lat. W tej krótkiej pracy skupię się wyłącznie na omówieniu zastosowania spektroskopii siłowej do analizy właściwości elastycznych biopolimerów, takich jak DNA i polisacharydy, których badaniom poświęciłem istotną część mojej pracy naukowej w ostatnich dwóch dekadach. Omówienie mechaniki pojedynczych cząsteczek białek czytelnik może znaleźć w innych oryginalnych lub przeglądowych pracach autora jak również innych badaczy, które dostępne są w literaturze światowej.
In this short review I will first concisely describe the principles of single-molecule force spectroscopy (SMFS) for measuring the mechanical properties of individual polymeric molecules, as implemented on an Atomic Force Microscope (AFM) platform. Next, I will review a selected number of the most striking, in my opinion, discoveries and observations accumulated in this field of research that now spans over 25 years of dynamic growth. This selection will be limited to biomolecular systems such as DNA and polysaccharides (sugars) that for the last two decades were an important part of my own research. The mechanical properties of single protein molecules are described by the author or other researchers in numerous original or review papers that can be found in the world literature.
Źródło:
Prace Instytutu Elektrotechniki; 2018, 280; 7-24
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surface analysis of long-term hemodialysis catheters made of carbothane (poly(carbonate)urethane) before and after implantation in the patients’ bodies
Autorzy:
Nycz, M.
Paradowska, E.
Arkusz, K.
Kudliński, B.
Krasicka-Cydzik, E.
Powiązania:
https://bibliotekanauki.pl/articles/306579.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
chropowatość powierzchni
mikroskopia sił atomowych
mikroskopia skaningowa
surface roughness
atomic force microscopy
scanning electron microscopy
Catheter-tissue contact
film
Opis:
The vascular cannulation is associated with a number of complications. The aim of this work was to study the composition and distribution of the film covering the surfaces of Mahurkar Maxid and Palindrome catheters, which were removed from the body of long-term hemodialysis patients. Moreover, the roughness and contact angle of the catheters were evaluated. Methods: Two brand new (as a reference) and thirty used catheters were the subject of the study. Their implantation period lasted from 4 months to a year and the reason for removal was the production of another vascular access or obstruction. Surfaces were analyzed by scanning electron microscope, atomic force microscope and goniometer. Results: The inner surfaces of the used catheters were covered with a film of various complexity which includes a plurality of protein, blood cell counts and the crystals. The closer to the distal part the film becomes more complex and multi-layered. Even the surfaces of brand new catheter were not completely smooth. The only significant difference between analyzed models was the presence of thrombus in the distal part of Mahurkar Maxid catheters, not in the Palindrome. Conclusions: The distal part of the catheters is the place most exposed to obstruction and infection, which may be due to not reaching the anticoagulant agent into this part. Not only the occurrence of side holes affects the formation of thrombus, but also their quantity, geometry and distribution which effect on fluid mechanics. The surface of the catheters needs to improvement to minimize the occurrence of defects and cracks.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 2; 47-53
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies