Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "microtomography" wg kryterium: Temat


Tytuł:
Pomiary porowatości skał metodą rentgenowskiej mikrotomografii komputerowej (Micro-CT)
Rock porosity measurements using Roentgen computed microtomography (Micro-CT)
Autorzy:
Dohnalik, M.
Zalewska, J.
Powiązania:
https://bibliotekanauki.pl/articles/183665.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
porowatość
mikrotomografia
porosity
microtomography
Opis:
Roentgen computed microtomography is an imaging technique that generates high resolution 3D images of internal structure, basing on difference in X-rays absorption inside the sample. Micro-CT provides new possibilities to obtain up to few microns resolution images of reservoir rocks in non destructive way. Such images enables to visualize and quantitative analysis of mineral composition and pore structure (volume, shape and pore throat diameter), which can be used to better understanding petrophysical properties such as permeability. This paper shows test of direct, quantitative porosity measurement based on 3D images obtained using Benchtop device and AVIZO software.
Źródło:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2009, 35, 2/1; 617-624
0138-0974
Pojawia się w:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of X-Ray Computed Microtomography for estimation of petrophysical parameters of reservoir rocks
Autorzy:
Kułynycz, Vitalij
Maruta, Michał
Powiązania:
https://bibliotekanauki.pl/articles/1179531.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
computer microtomography
petrophysical parameters
reservoir rocks
Opis:
In the reservoir geology, X-Ray microtomography (micro-CT) is mainly used for three-dimensional visualization of minerals and rocks. For rock sample testing, micro-CT technology enables quantitative measurements of the internal structure of rock material in a precise and non-destructive manner and, above all, allows accurate measurements of the spatial pore system. By using this method, you can get detailed information about porosity: it is possible to measure the length and number of channels pore, tracing their connections, visualization and quantitative assessment of their tortuosity and permeability, observing the penetration of water or oil in the rock, analyzing the degree of filling the pores of the rock different media and imaging and analysis of the wettability process. With this method you can also get a permeability analysis (in three orthogonal directions), estimate the fracture and hydraulic conductivity of the rock medium [1]. The paper discusses the method of X-Ray microtomography, presents data acquisition and reconstruction of the internal structure of reservoir rocks for hydrocarbons. The results of research on petrophysical parameters of Polish reservoir rocks and global oil and gas deposits were presented using a modern research method, based on the literature review of micro-CT method.
Źródło:
World Scientific News; 2017, 76; 91-107
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Osmotic dehydration and freezing as a suitable pretreatment in the process of vacuum drying kiwiberry: drying kinetics and microstructural changes
Autorzy:
Bialik, M.
Wiktor, A.
Witrowa-Rajchert, D.
Samborska, K.
Gondek, E.
Findura, P.
Powiązania:
https://bibliotekanauki.pl/articles/2082900.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
Actinidia arguta
X-ray microtomography
mathematical modelling
drying kinetics
Opis:
This study investigated the effects of osmotic dehydration and freezing on the kinetics and microstructure of vacuum-dried kiwiberry. Both fresh and previously frozen fruit were dehydrated in sucrose, maltitol and xylitol. Freezing and osmotic dehydration were selected as possible ways to improve the drying kinetics and positively influence the taste of the fruit. This experiment focused on the analysis of microstructural changes induced by applied processing methods using the X-ray microtomography technique. The results showed that the fruit pretreated in sucrose suffered the least structural damage as expressed by the largest condensation of small pores and thin cell walls. Freezing and xylitol resulted in the accumulation of larger pores and thicker walls. The most rapid drying time of 678-688 min was observed for unfrozen samples, dehydrated in sucrose and maltitol. Freezing slowed down the drying process, by 60-100 min, in comparison to the unfrozen samples. The applied mathematical models proved useful in predicting the kinetics of the drying process. The equation proposed by Midilli et al. provided the best fit for predicting the kinetics of the process.
Źródło:
International Agrophysics; 2020, 34, 2; 265-272
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray micro computed tomography characterization of porosity in Rotliegend sandstones on the northern slope of the Wolsztyn Ridge, western Poland
Autorzy:
Poszytek, A.
Mikołajewski, Z.
Dohnalik, M.
Powiązania:
https://bibliotekanauki.pl/articles/2060542.pdf
Data publikacji:
2016
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
Rotliegend
lithologic traps
sandstones
porosity
Wolsztyn Ridge
computed microtomography
Opis:
Natural gas in the Polish Rotliegend Basin occurs in porous and permeable aeolian sandstones, and traps are mostly structural. Lithological traps are rare and occur on the northern slope of the Wolsztyn Ridge where fluvial and aeolian sandstones overlap with alluvial facies. Both fluvial and aeolian sandstones are reservoir rocks in this area. The X-ray micro computed tomography (MCT) results and microscopic observations indicate that the sandstones in lithologic traps on the northern slope of the Wolsztyn Ridge form highly compartmentalized vertical reservoir rocks composed of four types of sandstones. The profiles are dominated by very low-porosity fluvial sandstones (F2), and low-porosity aeolian and fluvial sandstones (A2, F1). The A1 type of sandstones with high porosity (10%) occurs only in some sections of the profiles. The most important diagenetic processes that reduced porosity were compaction and cementation by carbonate cements. All studied sandstones were subjected to the same diagenetic processes. However, each of the processes ran with varying intensity in different types of sandstones. Detailed analyses of pore distribution by MCT methods with respect to primary depositional or lithofacies effects, and secondary diagenetic effects, help to understand the 3D geometry of pores and pore shape-size distributions. The results can be used in the studies of other sandstones with a different origin and age.
Źródło:
Geological Quarterly; 2016, 60, 4; 801-810
1641-7291
Pojawia się w:
Geological Quarterly
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wizualizacja przestrzeni porowej skał z wykorzystaniem mikrotomografii rentgenowskiej
Visualization of pore space using Roentgen microtomography
Autorzy:
Zalewska, J.
Dohnalik, M.
Powiązania:
https://bibliotekanauki.pl/articles/183670.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
mikrotomografia
wizualizacja
przestrzeń porowa
piaskowce
microtomography
visualization
pore space
sandstones
Opis:
Roentgen computed microtomography (micro-CT) allows visualizing internal structure of measured objects determined by density differences. Micro-CT measurements enable obtaining of many parallel 2D cross sections, which allows to project in 3D particular properties. Main micro-CT applications are porosity measurements and visualizations. The paper shows first results of measurements and imaging of rock porous space, using micro-CT method.
Źródło:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2009, 35, 2/1; 625-632
0138-0974
Pojawia się w:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Micro Computer Tomography to Identification of Pore Structure Parameters of Porous Materials
Autorzy:
Szczepański, Z.
Cieszko, M.
Gadzała, P.
Zych, G.
Powiązania:
https://bibliotekanauki.pl/articles/115469.pdf
Data publikacji:
2010
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Tematy:
volume porosity
bone tissue
computed microtomography
mCT
binarization
voxels
thresholding
microscopic
Opis:
The purpose of this paper is to apply the scans of microscopic geometry of human bones obtained by Micro Komputer Tomography method to identifi cation of their macroscopic pore structure parameters: volume porosity, permeability and tortuosity of pores and skeleton. These parameters, except the volume porosity, have been determined by simulations of microscopic processes of viscous fl uid fl ow and electrical current passage through virtual models of bones samples. The simulations wave performed using the COMSOL’s Multiphysics environment assigned for solution of boundary value problems described by partial diff erential equations, by use of the fi nite element method.
Źródło:
Challenges of Modern Technology; 2010, 1, 1; 90-91
2082-2863
2353-4419
Pojawia się w:
Challenges of Modern Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka utworów czerwonego spągowca w aspekcie badań rentgenowskiej mikrotomografii komputerowej i mikroskopii optyczne
Characteristics of Rotliegend sediments in view of X-ray microtomohraphy and optical microscopy investigations
Autorzy:
Dohnalik, Marek
Ziemianin, Konrad
Powiązania:
https://bibliotekanauki.pl/articles/1833915.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
czerwony spągowiec
mikrotomografia
petrografia
własności zbiornikowe
Rotliegend
microtomography
petrography
reservoir properties
Opis:
The article presents the results of microtomographic and petrographic investigations of Rotliegend sandstones collected from core material from wells located in the area of the Fore-Sudetic Monocline in its central and northern parts and also on the border of the Fore-Sudetic Monocline and the Mogilno - Łódź Synclinorium. Three areas were selected for the study: Czarna Wieś–Parzęczewo (19 samples), Środa Wielkopolska–Kromolice (21 samples) and Siekierki–Miłosław (21 samples). The aim of the petrologic and microtomographic studies was to investigate how the different reservoir properties of sandstones will be reflected in the results of the methods used. Strong differences between samples from the region of Środa Wielkopolska–Kromolice and the other studied areas have been demonstrated. In the case of this area several key factors were noticed: the highest average value of effective porosity; the highest average content of pores belonging to class VII (pore volume subsystem classification); three times higher average value of the CT porosity coefficient and the largest length of the average chord. Also in terms of petrography (composition of grains, cement type) it is a region where major differences, especially compared to the region of Czarna Wieś–Parzęczewo, can be seen. Based on the obtained results, it was possible to rank the examined regions in terms of their reservoir properties – from the worst (Czarna Wieś–Parzęczewo) to the best (Środa Wielkopolska–Kromolice). These conclusions are also confirmed by other petrophysical analyses (eg. mercury porosimetry, permeability analysis). Combination of the obtained microtomographic and petrographic results allowed to obtain a full characterization of the investigated samples – both in terms of the mineralogical composition of grains, as well as the development of the pore space. These data, especially in combination with the results of density and porosity analyses (helium pycnometry and mercury porosimetry), open up a number of possibilities to carry out different types of modeling (porosity, permeability) both on the scale of the sample itself, as well as the scale of a single well or even the whole basin, which is crucial for creating a hydrocarbon exploration strategy.
Źródło:
Nafta-Gaz; 2020, 76, 11; 765--773
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Saurichthys (Pisces, Actinopterygii) teeth from the Lower Triassic of Spitsbergen, with comments on their stable isotope composition (δ13C and δ18O) and X−ray microtomography
Autorzy:
Błażejowski, Błażej
Duffin, Christopher J.
Gieszcz, Piotr
Małkowski, Krzysztof
Binkowski, Marcin
Walczak, Michał
McDonald, Samuel A.
Withers, Philip J.
Powiązania:
https://bibliotekanauki.pl/articles/2051411.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Arctic
Svalbard
fish teeth
stable isotopes
x−ray microtomography
Lower Triassic
Źródło:
Polish Polar Research; 2013, 1; 23-38
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray microtomography (XMT) of fossil brachiopod shell interiors for taxonomy
Autorzy:
Blazejowski, B.
Binkowski, M.
Bitner, M.A.
Gieszcz, P.
Powiązania:
https://bibliotekanauki.pl/articles/23513.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Instytut Paleobiologii PAN
Tematy:
x-ray microtomography
fossil
brachiopod
shell
taxonomy
remains
paleontology
Terebratula terebratula
Opis:
The ability to see and understand the three−dimensional structure of an investigated object plays a key role in studying fossil remains. All living organisms are formed in threedimensions, but unfortunately fossilization processes often reduce overall shape, making it difficult to gather information about real overall appearance, functionality, and inner structure. Here, using a specimen of the brachiopod Terebratula terebratula we demonstrate a non−destructive technique for exploring the 3−D internal structure of fossil remains. The use of tomography allows the construction of a set of transverse serial sections in the manner used by brachiopod researchers for decades.
Źródło:
Acta Palaeontologica Polonica; 2011, 56, 2
0567-7920
Pojawia się w:
Acta Palaeontologica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Root Canal System Analysis with a Group of First Permanent Molars of Upper and Lower Jaw
Analiza systemu kanałowego w pierwszych zębach trzonowych szczęki i żuchwy
Autorzy:
Mroczek, K.
Szlązak, K.
Jodkowska, E.
Święszkowski, W.
Kurzydłowski, K.J.
Powiązania:
https://bibliotekanauki.pl/articles/355703.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
endodontics
root canal system configuration
microtomography
endodoncja
konfiguracja kanałów korzeniowych
mikrotomografia
Opis:
A progressive bacteria invasion on tooth tissues leads to pulp inflammation, microabscesses of the pulp, destruction and in consequence inflammation of periapical tissues. Therefore the aim of endodontic treatment is three dimensional debridement of a root canal from the vent in pulp chamber to the physiological narrowing. Therefore the aim of the study is analysis of root canal configuration, number of canals, presence of lateral canals and canal delta with the group of first permanent molars. At the same time the accuracy of the radiological examination (x-ray images) is estimated due to comprehension of X-ray images performed before teeth preparation with root canal system and after observation of transversal cuts by means of light microscopy and microtomography. This establishment is presented through the differences in conventional radiological image and clinical assessment.
Postępująca inwazja bakteryjna w tkankach zęba prowadzi do zapalenia miazgi, powstawania w niej mikroropnii, zniszczenia a w konsekwencji do zapalenia ozębnej. Z tego względu celem leczenia endodontycznego stało się trójwymiarowe oczyszczenie kanału korzeniowego od jego ujścia do przewężenia fizjologicznego. Dlatego celem pracy jest analiza konfiguracji, ilości kanałów korzeniowych, istnienia kanałów bocznych oraz delty korzeniowej w grupie pierwszych zębów trzonowych stałych w uzębieniu ludzkim. Jednocześnie ocenie poddawana jest dodatkowo swoistość badania radiologicznego (zdjęcia zębowe), poprzez porównanie zdjęć rentgenowskich wykonanych przed preparacją zębów z obrazem systemu kanałowego uzyskanego na podstawie mikrotomografii oraz po wykonaniu szlifów poprzecznych i ich obserwacji na mikroskopie świetlnym. Celem tej oceny jest zaprezentowanie rozbieżności pomiędzy oceną radiologiczną systemu kanałowego a kliniczną.
Źródło:
Archives of Metallurgy and Materials; 2014, 59, 2; 629-632
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of the carbonation zone in concrete using X-ray microtomography
Autorzy:
Łydżba, D.
Rajczakowska, M.
Stefaniuk, D.
Kmita, A.
Powiązania:
https://bibliotekanauki.pl/articles/178832.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
concrete
carbonation zone
X-ray microtomography
beton
strefa karbonatyzacji
mikrotomografia rentgenowska
Opis:
The article presents an application of X-ray microtomography for identification of the carbonation zone in concrete material. A concrete specimen subjected earlier to harsh environmental conditions is investigated. The material is firstly checked with the use of chemical corrosion indicators and then is subjected to microstructural analysis performed with the use of X-ray microtomography. Two different settings of scanning parameters are applied implying the image resolutions of approximately 14 μm per 1 pixel and about 7 μm per 1 pixel, respectively. The results obtained are then compared and analyzed. The depth of the carbonation zone is evaluated based on the attenuation curve. The paper highlights also the significance of the corrosion phenomenon in concrete structures. Details of the deterioration mechanisms in concrete are shortly presented.
Źródło:
Studia Geotechnica et Mechanica; 2014, 36, 1; 47-54
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie metody mikrotomografii komputerowej do określania struktury kompozytów bioresorbowalnych wytwarzanych przy pomocy generatywnej technologii laserowej
Application of microtomography methods for determination of the structure of bioresorbable composites made with generative laser technology
Autorzy:
Woźna, A.
Ziółkowski, G.
Powiązania:
https://bibliotekanauki.pl/articles/99019.pdf
Data publikacji:
2017
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
mikrotomografia komputerowa
kompozyt bioresorbowalny
technologie generatywne
computed microtomography
bioresorbable composite
generative technology
Opis:
Artykuł porusza zagadnienia związane z wykorzystaniem metod mikrotomografii komputerowej do badań struktury kompozytów bioresorbowalnych wytwarzanych przy pomocy generatywnej metody laserowej. Wytworzone materiały, o różnych kompozycjach, poddane zostały analizie struktury wewnętrznej tj. warstwowości, porowatości oraz obserwacji innych anomalii występujących po procesie wytwarzania.
The article raises issues related to the use of methods of computer microtomography to study the structure of bioresorbable composites produced using generative laser technology. Materials of various compositions were subjected to examination of internal structure, ie. stratification, porosity and other anomalies arisen after processing.
Źródło:
Aktualne Problemy Biomechaniki; 2017, 12; 97-104
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray microtomography (μCT) as a useful tool for visualization and interpretation of shear strength test results
Autorzy:
Stefaniuk, D.
Tankiewicz, M.
Stróżyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/178870.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
X-ray microtomography
shear strength
shear plane
fine-grained soil
triaxial test
Opis:
The paper demonstrates the applicability of X-ray microtomography (μCT) to analysis of the results of shear strength examinations of clayey soils. The method of X-ray three-dimensional imaging offers new possibilities in soil testing. The work focuses on a non-destructive method of evaluation of specimen quality used in shear tests and mechanical behavior of soil. The paper presents the results of examination of 4 selected clayey soils. Specimens prepared for the triaxial test have been scanned using μCT before and after the triaxial compression tests. The shear strength parameters of the soils have been estimated. Changes in soil structure caused by compression and shear failure have been presented as visualizations of the samples tested. This allowed for improved interpretation and evaluation of soil strength parameters and recognition of pre-existing fissures and the exact mode of failure. Basic geometrical parameters have been determined for selected cross-sections of specimens after failure. The test results indicate the utility of the method applied in soil testing.
Źródło:
Studia Geotechnica et Mechanica; 2014, 36, 4; 47-55
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda pomiaru gęstości osadu pokoagulacyjnego z zastosowaniem tomografii rentgenowskiej
Measurement method of sediment densities after coagulation using x-ray tomography
Autorzy:
Rząsa, M. R.
Podgórni, E.
Powiązania:
https://bibliotekanauki.pl/articles/268323.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
gęstość osadu
koagulacja
mikrotomografia rentgenowska
density of sediment
coagulation
X-ray microtomography
Opis:
Koagulacja jest jednym z procesów oczyszczania wody. Polega na destabilizacji układu koloidalnego i aglomeracji cząstek, które następnie usuwa się w procesach sedymentacji, flotacji czy filtracji. Powstałe cząstki pokoagulacyjne charakteryzują się zróżnicowanym kształtem, wielkością oraz strukturą. Szybkość opadania takich cząstek w dużej mierze zależy od ich gęstości. Struktura cząstek powoduje, że wyróżnia się dwa rodzaje porów. Makropory, które nie powinny być uwzględniane przy wyznaczaniu gęstości oraz mikropory, które stanowią cechę charakteryzującą dany osad pokoagulacyjny. Gęstość wyznaczono metodą wagową dla odpowiednio przygotowanych próbek. Ponieważ proces prasowania może niszczyć mikrostrukturę osadu, przeprowadzono badania mające na celu określenie stopnia sprasowania próbek, aby zminimalizować błędy wyznaczenia gęstości. Badania te prowadzono za pomocą tomografu rentgenowskiego, dzięki któremu możliwe było wyznaczenie objętości danej próbki z korektą makroporowatości. W pracy przedstawiono wyniki badań oraz parametry graniczne procesu przygotowywania próbek.
Coagulation is one of the processes of water purification, which consists in the destabilization of the dispersion and agglomeration of the particles, which are removed in the process of sedimentation, flotation or filtration. After the coagulation particles have a varied shape, size and porous structure. The rate of descent of such particles largely depends on their density. The structure of the particles causes two types of pores. Macropores that should not be taken into account when determining the density, and micropores, which are a characteristic feature of the sediment after coagulation process. To determine the density of sludge samples were subjected to compression, in order to eliminate the macropores and then, after designation of sample volume, density was determined by weighing. The precipitate was prepared based on a prepared water model, to which was added a coagulant Flokor 1.2A. The precipitate was filtered on a cellulose filter, and then subjected to a drying process. The dry sludge was pressed on the press impact. Because of the pressing process can destroy the microstructure of the sediment, studies have been conducted to determine the degree of compression of samples to minimize errors while determine the density. These studies were carried out using X-ray tomography, it was possible to designate the volume of the sample while subtraction residues macropores. For the correct determination of the volume, determination the correct number of threshold is necessary, based on which is possible to qualify individual pixels. In order to clearly identify which pixels represent sediment, it was necessary to carry out the image processing. That process were performed using LabVIEW software and Vision module. The paper presents results of research for density measurement and sets limits for the sample preparation process.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 159-162
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametry morfologiczne pian stałych –metody i wyzwania
Morphological parameters of solid foams – chalanges faced
Autorzy:
Gancarczyk, A.
Iwaniszyn, M.
Piątek, M.
Leszczyński, B.
Ziółkowski, G.
Piech, D.
Janus, B.
Kleszcz, T.
Kołodziej, A.
Powiązania:
https://bibliotekanauki.pl/articles/306081.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Inżynierii Chemicznej PAN
Tematy:
piany stałe
parametry morfologiczne
mikrotomografia komputerowa
solid foam
morphological parameters
computed microtomography
Opis:
Parametry morfologiczne pian stałych wyznaczone zostały przy użyciu mikrotomografii komputerowej, mikroskopii optycznej oraz piknometrii helowej. Dla pierwszej z zaproponowanych technik sprawdzono wpływ wielkości woksela oraz metody binaryzacji obrazów na mierzone wielkości. Porównano wartości parametrów morfologicznych pian stałych otrzymane zaproponowanymi technikami oraz przedyskutowano ewentualne różnice.
Morphological parameters of the solid foams have been determined using computed microtomography, optical microscopy and helium pycnometry. For the first technique, impacts were studied of the voxel size and method of the image binarization on the measured parameters. Morphological parameters derived were compared and the differences discussed.
Źródło:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk; 2016, 20; 155-165
1509-0760
Pojawia się w:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of bone volume porosity based on histograms of the mCT scans
Autorzy:
Gadzała, P.
Szczepański, Z.
Zych, G.
Powiązania:
https://bibliotekanauki.pl/articles/115459.pdf
Data publikacji:
2010
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Tematy:
volume porosity
bone tissue
computed microtomography
mCT
histogram
probability distribution
voxels
thresholding
microscopic
Opis:
The new method is proposed in the paper for determination of volume porosity of bone tissue based on histograms of 3D mCT scans and also precise defi nition of the threshold value of relative density preserving calculated volume porosity during the reconstruction of the binary image of sample. In this method the normed histogram is considered as a probability distribution of relative mass density in the bone sample. It was shown that the normed histograms of increasing 3D sample are convergent to the limit curve which can be interpreted as a representative histogram of given sample. The limit histograms have been used to determine: the distributions of relative densities in the sets of voxels of pore and skeleton type and their characteristics, the volume porosities of both samples and thresholds values of their binarisation.
Źródło:
Challenges of Modern Technology; 2010, 1, 1; 88-89
2082-2863
2353-4419
Pojawia się w:
Challenges of Modern Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-invasive analysis and visualization of objects from FSW AlSi9Mg/2017A aluminum alloy joints
Nieinwazyjna analiza i wizualizacja obiektów w złączach AlSi9Mg/2017A wytwarzanych metodą Friction Stir Welding
Autorzy:
Wójcicka, A.
Mroczka, K.
Kowalski, M.
Powiązania:
https://bibliotekanauki.pl/articles/264301.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
X-ray microtomography
image analysis
aluminum alloys
FSW
mikrotomografia komputerowa
analiza obrazów
stopy aluminium
Opis:
Friction stir welding (FSW) technology allows for the welding of materials that differ in their chemical compositions, microstructures, and properties. When selecting the parameters, it is necessary to analyze the structure of a weld and eliminate the defects. The use of X-ray microtomography creates the possibility of precise imaging of a joint structure – especially when it contains defects (voids). The tests were carried out on an FSW joint made with both 2017A and AlSi9Mg aluminum alloys. The macrostructure was cross-sectional, and a defect was found in the middle part of the joint and on the advancing side. We used a conventional method of observation light microscopy. Then, an analysis was performed using X-ray microtomography, which revealed the shape of the defect in 3D. Individual cross-sections were extracted, which enabled us to measure the geometric quantities. A dependence was found for the shape of the defect on the welding parameters and the variability of its construction. The usefulness of this advanced material imaging technology for the analysis of FSW welds has been confirmed.
Technologia FSW umożliwia zgrzewanie materiałów różniących się składem chemicznym, mikrostrukturą i właściwościami. Przy doborze parametrów konieczna jest analiza struktury złącza i eliminacja ewentualnych wad. Zastosowanie mikrotomografii komputerowej umożliwia precyzyjne obrazowanie budowy złącza, szczególnie gdy zawiera wady (pustki). Badania przeprowadzono na złączu FSW stopów aluminium 2017A i AlSi9Mg. Zbadano makrostrukturę na przekroju poprzecznym i stwierdzono obecność wady w środkowej części złącza i po stronie natarcia. Zastosowano konwencjonalną metodę obserwacji – mikroskopię świetlną. Następnie wykonano analizę złącza z zastosowaniem tomografii komputerowej, która ujawniła kształt wady w wymiarze 3D. Wyekstrahowano poszczególne przekroje, które umożliwiły wykonanie pomiarów wielkości geometrycznych. Stwierdzono zależność kształtu wady od parametrów zgrzewania oraz zmienność jej budowy. Potwierdzono przydatność tej zaawansowanej technologii obrazowania budowy materiałów do analizy złącz FSW.
Źródło:
Metallurgy and Foundry Engineering; 2018, 44, 3; 145-152
1230-2325
2300-8377
Pojawia się w:
Metallurgy and Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Struktura wewnętrzna pian RVC
Inner structure of the RVC foam
Autorzy:
Macek, W.
Gancarczyk, A.
Iwaniszyn, M.
Sindera, K.
Korpyś, M.
Stępak, B.
Kołodziej, A.
Powiązania:
https://bibliotekanauki.pl/articles/306039.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Inżynierii Chemicznej PAN
Tematy:
piany RVC
mikrotomografia komputerowa
mikroskopia
ablacja laserowa
RVC foam
computed microtomography
microscopy
laser ablation
Opis:
Analiza wewnętrznej struktury szkieletu pian węglowych (Reticulated Vitreous Carbon, RVC), przeprowadzona za pomocą mikrotomografii komputerowej, nie pozwoliła w sposób jednoznaczny określić w jakim stopniu ich struktura jest nieciągła. Dlatego, w celu dokładniejszej obserwacji zastosowano elektronową mikroskopię skaningową oraz optyczną. Wykonano również mikroprzekroje plazmą ksenonu i ablację laserową. Ponadto przeanalizowano topografię powierzchni przełomu szkieletu pian RVC. Na podstawie przeprowadzonych badań stwierdzono, że szkielet pian RVC nie wykazuje wewnętrznej porowatości.
The analysis of the internal structure of RVC foams (Reticulated Vitreous Carbon) skeleton carried out by computed microtomography, did not allow to unambiguously determine to what extent their structure is discontinuous. Therefore, for more accurate observation, scanning electron microscopy and optical microscopy were used. Micro-cuts with Xenon plasma and laser ablation were also done. In addition, the topography of the breakthrough surface of the RVC foam skeleton was analyzed. On the basis of the conducted tests, it was found that the RVC foam skeleton does not show internal porosity.
Źródło:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk; 2018, 22; 69-76
1509-0760
Pojawia się w:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis and Characterization of Co-Cs-Nd-Sr-Doped Perovskite-Rutile-Type Structure
Autorzy:
Smolinski, T.
Zhao, L.
Rogowski, M.
Wawszczak, D.
Olczak, T.
Brykala, M.
Powiązania:
https://bibliotekanauki.pl/articles/355628.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Synroc
X-ray diffraction
Rutherford backscattering
particle induced X-ray emission
Roentgen computed microtomography
Opis:
The perovskite type matrix is considered as solidification material for high-level radioactive waste. In this work the perovskite-rutile-type matrix doped by Co, Cs, Nd and Sr which simulate nuclear waste was prepared by sol-gel route. The material was characterized by several methods such as: X-ray diffraction, energy dispersive X-ray spectrometer, and particle induced X-ray emission combined with Rutherford backscattering spectrometry. The analyzes confirmed chemical composition Co-Cs-Nd-Sr-doped perovskite-rutile-type structure. A virtual model of the pellet`s structure was created non-destructively by Roentgen computed micro-tomography. The leaching tests confirmed high chemical resistance of the matrix.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 4; 1417-1423
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie mikrotomografii komputerowej (μCT) w diagnostyce jakości zabezpieczenia otworów wiertniczych przed migracją gazu
Computer microtomography (μCT) application in wells anti gas migration sealing quality inspections
Autorzy:
Bolewski, Ł.
Karpiński, B.
Kmieć, M.
Szkodo, M.
Powiązania:
https://bibliotekanauki.pl/articles/167396.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
migracja gazu
mikrotomografia komputerowa
jakość zacementowania
gas migration
computed microtomography (μCT)
cementing job quality
Opis:
Artykuł opisuje badania nad negatywnym zjawiskiem występującym w wiertnictwie otworowym pod nazwą migracja gazu z wykorzystaniem metody mikrotomografii komputerowej μCT (ang. computed microtomography). Opisano główne przyczyny powstawania tego negatywnego zjawiska polegającego na przepływie gazów, a także płynów w zaczynie cementacyjnym lub kamieniu cementowym. Przygotowano próbki imitujące zacementowany odcinek rur okładzinowych. Skupiono się na wykorzystaniu mikrotomografii komputerowej, oraz analizie zrekonstruowanego trójwymiarowego obrazu w celu sprawdzenia jakości zacementowania. Przedstawiono zalety tej metody oraz możliwości analizy powstałych kamieni cementowych.
This paper presents a description of the gas migration phenomenon. Main causes of this negative phenomenon consisting in fluid or gas flow in the cement slurry or bounded cement sheath have been described. The paper describes the use of the computed microtomography (μCT) and analysis of the reconstructed three-dimensional (3D) images, in order to check the quality of cementation samples prepared at the Faculty of Mechanical Engineering. The paper presents the advantages and opportunities of X-ray computed microtomography analysis of the bonded cement sheath.
Źródło:
Przegląd Górniczy; 2017, 73, 5; 50-57
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przestrzenne badanie systemu porowego skał węglanowych na podstawie cyfrowej analizy obrazów mikrotomograficznych z wykorzystaniem języka Python
Spatial analysis of carbonate pore system based on digital image analysis of X-ray microtomography data using Python language
Autorzy:
Fheed, Adam
Hadro, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2076181.pdf
Data publikacji:
2021
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
mikrotomografia rentgenowska
Phyton
węglanowe skały zbiornikowe
porowatość
X-ray microtomography
Python
carbonate reservoir rocks
porosity
Opis:
The main aim of this contribution is to combine a Python-supported analysis of X-ray microtomography (µCT) images and the transmitted-light microscopy to resolve the factors controlling the variability of petrophysical parameters in carbonate rocks. A self-developed Python script for the evaluation of pore connectivity and the computation of pore sizes based on µCT data was prepared. The script was launched on a carbonate sample with drawn from a drill core representing the Late Permian Zechstein Limestone (Ca1) formation from the Wolsztyn Ridge area in West Poland. The sample was taken from the upper part of the isolated Kokorzyn Reef, corresponding to a brachiopod and bivalve-rich zone. The plug had a cylindrical shape, the diameter of 2.54 cm and the height of approximately 4.6cm. The entire volume of the plug was scanned using a GE Nanotom Sdevice. The 3D-reconstructeddatasetobtainedwith spatial resolution of 0.02 mm underwent cropping, contrast adjustment, noise reduction and porosity extraction using open-source Fiji software. The binarized porosity image was loaded into the Python script. Python scripting was found efficient in carbonate pore system examination. The code first extracted the connected pore system of the largest volume and computed the smallest distances between porosity voxels and corresponding pore walls. The obtained results were confronted with the spatially-adjusted microphotographs taken in plane-polarized transmitted light. The results have shown that narrow and isolated pores occurred within the spines of brachiopods. The largest voids were found inside the brachiopod shells. Moreover, many pores were associated with partially dissolved fragments of bivalves. Porosity reduction was -most outlined in the zones showing the scarcity of fossils.
Źródło:
Przegląd Geologiczny; 2021, 69, 6; 357--360
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of X-ray computed microtomography for graptolite detection in rock based on core internal structure visualization
Autorzy:
Kaczmarek, Ł.
Kozłowska, A.
Maksimczuk, M.
Wejrzanowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/139097.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
computed microtomography
visualization
graptolites
Silurian
Baltic Basin shale
mikrotomografia komputerowa
wizualizacja
graptolity
sylur
łupki basenu bałtyckiego
Opis:
This paper presents for the first time X-ray computed microtomography (μCT) analysis as a technique for Silurian graptolite detection in rocks. The samples come from the Jantar Bituminous Claystones Member of the Opalino core, Baltic Basin, northern Poland. Images were obtained with spatial resolution of 25 μm, which enabled the authors to create a 3-D visualization and to calculate the ratio of fissure and graptolite volume to the total sample volume. A set of μCT slices was used to create a 3-D reconstruction of graptolite geometry. These μCT slices were processed to obtain a clearly visible image and the volume ratio. A copper X-ray source filter was used during exposure to reduce radiograph artifacts. Visualization of graptolite tubaria (rhabdosomes) enabled Demirastrites simulans to be identified. Numerical models of graptolites reveal promising applications for paleontological research and thus for the recognition and characterization of reservoir rocks.
Źródło:
Acta Geologica Polonica; 2017, 67, 2; 299-306
0001-5709
Pojawia się w:
Acta Geologica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie 3D struktury przestrzeni porowej cementów metodą mikrotomografii rentgenowskiej (micro-CT)
Examination of internal pore space 3D images of cement rock with use of Roentgen Computed Tomography (Micro-CT)
Autorzy:
Dohnalik, M.
Zalewska, J.
Kut, Ł.
Kaczmarczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/349787.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
cement
struktura porowa kamieni cementowych
rozwój porowatości
mikrotomografia
cement rock pore structure
pore structure evolution
microtomography
Opis:
Metoda mikrotomografii rentgenowskiej (micro-CT) jest nieniszczącą metodą badawczą, która umożliwia wizualizację budowy wewnętrznej obiektów (w geologii np. skał i cementów). Metoda polega na rejestracji projekcji promieniowania X badanej próbki pod różnymi kątami, a następnie rekonstrukcji na tej podstawie struktury wewnętrznej próbki. Wizualizowanym parametrem jest współczynnik atenuacji liniowej, który zależy od energii promieniowania X, liczby atomowej pierwiastków budujących obiekt oraz gęstości badanej próbki. Micro-CT może być stosowana zarówno do jakościowej wizualizacji wewnętrznej struktury cementów, jak również do pozyskiwania danych ilościowych. Celem tego artykułu jest przedstawienie zastosowania mikrotomografii rentgenowskiej w badaniu cementów. W pracy zaprezentowano, po raz pierwszy w kraju, wyniki mikrotomograficznych badań mikrostruktury zaczynów cementowych w różnym wieku (1 do 28 dni). Wyniki pozwoliły przeanalizować zmiany w sieci porowej zaczynów podczas ich starzenia. Wykazano znaczące różnice w ewolucji porów pomiędzy próbami zaczynów o różnych składach. Wyniki te pokazują możliwości metody micro-CT w badaniu materiałów cementowych. Główną zaletą metody jest możliwość odtworzenia sieci porowej oraz prześledzenia zmian wielkości porów w czasie. Dzięki tej metodzie możliwe jest także badanie nowych cech, takich jak dystrybucja przestrzenna struktury porowej oraz określenie jej przewodności.
The X-ray computed microtomography (micro-CT) is a non-destrictive method for visualization of objects' internal structures (in geology - e.g. rocks or cement stones). Sample's X-ray projections at different angles are recorded and, on the basis of them, the objects' internal structure is reconstructed. Visualized parameter is the linear attenuation coefficient (proportional to X-ray's energy, material's density and atomic number of elements in object's structure). The micro-CT may be used to visualize the cement's internal structure and its quantitative analysis. The aim of this paper is to show application of micro-CT in cementary rocks examination. In this work the results of micro-CT measurement for cements of different age (1-28 days) are shown first time in Poland. Obtained results allowed to analyze changes of pore network during the cement rock's shrinking. Significant pore space evolution changes in case of cement rocks with different composition were observed. Results shown that micro-CT method is applicable for cement rocks examination. The main adventage of micro-CT is the ability to reconstruction of pore space and observation of its changes in time. Also the pores' spatial distribution and tortuosity may be examined.
Źródło:
Górnictwo i Geoinżynieria; 2010, 34, 4; 157-165
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie mikrotomografii komputerowej do badania orientacji klastów w glinach lodowcowych
Application of computed microtomography in clast orientation studies in glacial tills
Autorzy:
Hermanowski, Piotr
Duda, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2075992.pdf
Data publikacji:
2019
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
mikrotomografia
gliny lodowcowe
drumlin
procesy subglacjalne
stargardzkie pole drumlinowe
microtomography
glacial till
subglacial processes
Stargard drumlin field
Opis:
Limitations of macroscopic measurements and observations of glacial tills, no matter how informative they are, have contributed to the development of micromorphological analysis first in thin sections, since the 80’s using X-ray computed tomography, and recently X-ray computed microtomography (μ-CT). The цCT has found wide applications in science including earth sciences where is used for imagining various geological samples in the 3D view. The sampling procedure and preparation of samples do not generate much effort, and eventually, allow analysis of samples with a preserved undisturbed structure. Herein, we present a short review and methodology of μCT as well as its application to the study of glacial tills. For example, we analyzed a subglacial till sample from the lee side of a drumlin located in the Stargard drumlin field area, NW Poland. The results show a distinctive bimodal pattern of clast fabrics which is interpreted as a result of subglacial till squeezing. Smaller clasts are obliquely oriented to the major direction of the ice flow whereas the larger clasts orientation is approximately in accordance with the major shear stress direction. Overall, our data emphasize the potential of the μ-CT in glacial till studies.
Źródło:
Przegląd Geologiczny; 2019, 67, 8; 653--661
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Morphology and surface topography of Ti6Al4V lattice structure fabricated by selective laser sintering
Autorzy:
Maszybrocka, J.
Stwora, A.
Gapiński, B.
Skrabalak, G.
Karolus, M.
Powiązania:
https://bibliotekanauki.pl/articles/202149.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
metal porous implant
selective laser sintering
surface roughness
X-ray microtomography
selektywne spiekanie laserowe
chropowatość powierzchni
Mikrotomografia
Opis:
Construction of metallic implants with a porous structure that mimics the biomechanical properties of bone is one of the challenges of orthopedic regenerative medicine. The selective laser sintering technique (SLS) allows the production of complex geometries based on three-dimensional model, which offers the prospect of preparing porous metal implants, in which stiffness and porosity can be precisely adjusted to the individual needs of the patient. This requires an interdisciplinary approach to design, manufacturing and testing of porous structures manufactured by selective sintering. An important link in this process is the ability to assess the surface topography of the struts of porous structure. The paper presents a qualitative assessment of the surface morphology based on SEM studies and methodology that allows for quantitative assessment of stereometric structure based on micro-tomographic measurements.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 1; 85-92
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies