Active Physical Remediation of Acid Mine Drainage: Technologies Review and Perspectives
Autorzy:
Mulopo, Jean
Powiązania:
https://bibliotekanauki.pl/articles/2105273.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ion-exchange
acid mine drainage
electrochemical
adsorption
membrane process
active physical treatment
Opis:
The successful acid mine drainage (AMD) treatment needs site-specific installation and implementation, as well as the deployment of technology that is compatible with the pollutants contained in the AMD. If key by-products of the AMD can be recovered, the financial sustainability of the AMD remediation method may be greatly improved. Additional research into novel and innovative solutions is necessary to advance in this direction. To accomplish this, it is necessary to have a complete awareness of current remediation technologies that are available and accessible. Active physical treatment methods such as ion exchange, adsorption, electrochemistry, and membrane techniques were examined in this article. Membrane technology excels in terms of ease of use, versatility, and environmental effect but produces brine streams the management of which remains vital for future adoption of the technology. Liquid membranes (LM), Micellar Enhanced Ultra-Filtration (MEUF), and Polyelectrolyte Enhanced Ultra-Filtration (PEUF) are all innovative membrane technologies that may provide some possibilities for metal recovery from chemical sludge and/or brine streams. Electrochemical technologies are considered an attractive alternative for AMD treatment, because they require only electricity as a consumable and can treat AMD to high standards by removing metals via (co)precipitation and sulfate via ionic migration (when an anion-exchange membrane is used in the configuration), while producing significantly less sludge. However, the accepted shortcomings include membrane/electrode fouling produced by (co)precipitates on the active surfaces necessary for the process, a lack of understanding regarding the effective scaling up to industrial scale, and the relatively expensive capital expenditure (CAPEX) required. The removal of heavy metals from AMD effluents by adsorption has a number of technical and environmental benefits, including high efficiency, and environmental friendliness. Despite its benefits, this technique has certain hurdles, such as the production process for low-cost adsorbents.
Źródło:
Journal of Ecological Engineering; 2022, 23, 6; 148--163
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Fenton Reaction and Nanofiltration for the Recovery of Process Water
Zastosowanie procesu Fentona i nanofiltracji do odzysku wody technologicznej
Autorzy:
Żyłła, Renata
Kos, Lech
Powiązania:
https://bibliotekanauki.pl/articles/234017.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
membrane filtration
Fenton process
textile wastewater
filtracja membranowa
proces Fentona
ścieki tekstylne
Opis:
In this study, the Fenton process and nanofiltration were used to purify wastewater from dyeing with reactive dyes. Ferrous sulfate doses ranging from 100 to 1000 mg/dm3 and hydrogen peroxide doses ranging from 2.5 to 10 cm3/dm3were applied. It was found that in the whole range of ferrous sulfate doses, the degree of decolorisation was very high, reaching 97-99%. Consequently the wastewater from the Fenton process was practically completely decolorised. In the case of COD, with increasing doses of ferrous sulfate, the reduction rate initially increased from 25 to 38% and then decreased to 28%. An increase in the hydrogen peroxide dose resulted in a rise in COD reduction to about 50%. It was found that application of the Fenton reaction before the nanofiltration process improved filtration parameters. A clear reduction in the fouling effect of the membrane in the integrated wastewater treatment process was reported as compared to nanofiltration alone.
W pracy zastosowano proces Fentona i nanofiltrację do oczyszczania ścieków pochodzących z procesów barwienia barwnikami reaktywnymi. Stosowano dawki siarczanu żelazawego w zakresie od 100 do 1000 mg/dm3 i dawki nadtlenku wodoru w zakresie od 2,5 do 10 cm3/dm3. Stwierdzono, że w całym zakresie stosowanych dawek siarczanu żelazawego uzyskany stopień odbarwienia ścieków był bardzo wysoki rzędu 97-99%. Tak więc ścieki po procesie Fentona były praktycznie całkowicie odbarwione. W przypadku ChZT wraz ze zwiększaniem stosowanej dawki siarczanu żelazawego stopień redukcji początkowo wzrósł z 25 do 38%, a następnie obniżył się do poziomu 28%. Zwiększając dawkę nadtlenku wodoru uzyskano wzrost stopnia redukcji ChZT do około 50%. Stwierdzono, że zastosowanie procesu Fentona przed procesem nanofiltracji pozwoliło na poprawę parametrów filtracji. Odnotowano wyraźne zmniejszenie „efektu foulingu” membrany w zintegrowanym procesie oczyszczania ścieków, w porównaniu z samą nanofiltracją.
Źródło:
Fibres & Textiles in Eastern Europe; 2019, 2 (134); 101-106
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Membrane gas separation module with pulsed retentate for low-permeable component recovery
Autorzy:
Battalov, Stanislav V.
Trubyanov, Maxim M.
Puzanov, Egor S.
Sazanova, Tatyana S.
Drozdov, Pavel N
Vorotyntsev, Ilya V.
Powiązania:
https://bibliotekanauki.pl/articles/185429.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
membrane gas separation
unsteady-state operation
process intensification
separation
efficiency
membrane module
separacja gazów membranowych
operacja niestabilna
intensyfikacja procesu
separacja
wydajność
moduł membranowy
Opis:
The paper presents the experimentalstudy of a novel unsteady-statemembrane gas separation approachfor recovery of a slow-permeant component in the membrane module with periodical retentate with-drawals. The case study consisted in the separation of binary test mixtures based on the fast-permeantmain component (N2O, C2H2) and the slow-permeant impurity (1% vol. of N2)using a radial counter-current membrane module. The novel semi-batch withdrawal technique was shown to intensify theseparation process and provide up to 40% increase in separation efficiency compared to a steady-stateoperation of the same productivity.
Źródło:
Chemical and Process Engineering; 2019, 40, 1; 57--65
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nanofiltration as an effective method of NaOH recovery from regenerative solutions
Proces nanofiltracji jako efektywna metoda odzysku NaOH z roztworów poregeneracyjnych
Autorzy:
Urbanowska, Agnieszka
Kabsch-Korbutowicz, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/205095.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
recovery
nanofiltration
NaOH solution
chemical cleaning
pressure-driven membrane process
poprawa
nanofiltracja
roztwór NaOH
czyszczenie chemiczne
proces membranowy napędzany ciśnieniem
Opis:
The objective of this study was to determine the suitability of the nanofiltration (NF) process to recover the regenerating agent (NaOH) from spent solutions contaminated with organic compounds. NaOH recovery from 2 spent regenerant solutions after cleaning ultrafiltration (UF) membranes (polymeric 30 kDa, ceramic 300 kDa) fouled with natural humic water was carried out using 2 types of NF membranes: NP010P (Na2SO4 rejection: 35–75%) and NP030P (Na2SO4 rejection: 80–95%). It has been shown that the use of the NP030P membrane allows for very high separation efficiency of organic compounds (up to 97% of color intensity reduction) from the tested solutions. It was also observed that the effectiveness of the process, in addition to the type of membrane used, also depends on the time of NF process – along with the elapsed time of the process, the hydraulic and separation properties of the tested membranes deteriorated. The obtained results showed that the use of both tested NF membranes allows for the recovery of NaOH to a degree that allows its re-use.
W przeprowadzonych badaniach określono przydatność procesu nanofiltracji (NF) do odzysku czynnika regenerującego (NaOH) z roztworów poregeneracyjnych zanieczyszczonych związkami organicznymi. Uzyskane wyniki pokazały, że użycie obu testowanych membran nanofiltracyjnych (NP010P oraz NP030P) pozwala na odzysk NaOH w stopniu pozwalającym na jego ponowne użycie. Wykazano, że zastosowanie membrany NP030P pozwala na uzyskanie bardzo wysokiej skuteczności separacji związków organicznych (do 97% usunięcia barwy) z testowanych roztworów. Zaobserwowano również, że skuteczność procesu, oprócz rodzaju użytej membrany, zależała także od czasu prowadzenia nanofiltracji – wraz z upływającym czasem procesu pogarszały się właściwości hydrauliczne i separacyjne testowanych membran.
Źródło:
Archives of Environmental Protection; 2019, 45, 2; 31-36
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the absorbing pervaporation technique for ammonia recovery after the haber process
Autorzy:
Atlaskin, A.
Petukhov, A. N.
Yanbikov, N. R.
Salnikova, M.E.
Sergeeva, M. S.
Vorotyntsev, V. M.
Vorotyntsev, I. V.
Powiązania:
https://bibliotekanauki.pl/articles/184857.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gas separation
absorbing pervaporation
ammonia
process intensification
membrane
separacja gazów
amoniak
intensyfikacja procesu
membrana
Opis:
A novel absorbing pervaporation hybrid technique has been evaluated experimentally for the recovery of ammonia from the gas mixture in a recycle loop of synthesis plants. This process of hybridization brings together the combination of energy-efficient membrane gas separation based on poly(dimethylsiloxane) poly(diphenylsilsesquioxane) with a high selective sorption technique where a water solution with polyethylene glycol 400 (PEG-400) was used as the liquid absorbent. Process efficiency was studied using the pure and mixed gases. The influence of PEG-400 content in aqueous solutions on process selectivity and separation efficiency was studied. The ammonia recovery efficiency evaluation of an absorbing pervaporation technique was performed and compared with the conventional membrane gas separation. It was shown that the absorbing pervaporation technique outperforms the conventional membrane method in the whole range of productivity, producing the ammonia with a purity of 99.93 vol.% using the PEG 80 wt.% solution. The proposed method may be considered as an attractive solution in the optimization of the Haber process.
Źródło:
Chemical and Process Engineering; 2018, 39, 3; 323--333
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Membrane reactor for enzymatic depolymerization – a case study based on protein hydrolysis
Autorzy:
Noworyta, A.
Trusek, A.
Wajsprych, M.
Powiązania:
https://bibliotekanauki.pl/articles/778609.pdf
Data publikacji:
2018
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
enzymatic membrane reactor
membrane selectivity
volume enzyme immobilization
biopolymer
hydrolysis
process efficiency
Opis:
The efficiency of enzymatic depolymerization in a membrane reactor was investigated. The model analysis was performed on bovine serum albumin hydrolysis reaction led by three different enzymes, for which kinetic equations have different forms. Comparing to a classic reactor, the reaction yield turns out to be distinctly higher for all types of kinetics. The effect arises from increasing (thanks to the proper selectivity of the applied membrane) the concentration of reagents in the reaction volume. The investigations indicated the importance of membrane selectivity election, residence time and at non-competitive inhibition the substrate (biopolymer) concentration in feed stream. Presented analysis is helpful in these parameters choice for enzymatic hydrolysis of different biopolymers.
Źródło:
Polish Journal of Chemical Technology; 2018, 20, 4; 44-48
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of advanced oxidation process (H2O2/UV) for removal of organic materials from pharmaceutical industry effluent
Autorzy:
Azizi, E.
Fazlzadeh, M.
Ghayebzadeh, M.
Hemati, L.
Beikmohammadi, M.
Ghaffari, H. R.
Zakeri, H. R.
Sharafi, K.
Powiązania:
https://bibliotekanauki.pl/articles/207937.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
oksydacja
ścieki farmaceutyczne
substancje organiczne
odpady farmaceutyczne
ChzT
bioreaktor
amoxicillin
UV/H2O2
COD
przemysł farmaceutyczny
waste water
membrane bioreactor
UV/H2O2 process
reactor
mineralization
pharmaceutical industry effluent
Opis:
Pharmaceutical wastewater is one of the major complex and toxic industrial effluents containing little or no biodegradable organic matters. In this study, H2O2/UV based advanced oxidation process (AOP) was used to remove organic materials from pharmaceutical industry effluent. For the chemical oxygen demand (COD) removal radiation of medium pressure mercury vapor UV lamp was used in the presence of hydrogen peroxide (H2O2/UV). Results indicated that the efficiency of COD removal depends on the initial concentration H2O2, oxidation time and pH. The efficiency of COD removal at low H2O2con-centration was very low even coupled with UV light, which can be attributed to the low generation of hydroxyl radicals (OH). At high concentration of H2O2 (500 mg/dm3) and optimum pH (pH = 4), 87.6% removal efficiency could be achieved during 70 min oxidation. For high concentration of H2O2 (500 mg/dm3) at pH 3 and 7, the maximum COD removal efficiency was 28.5% and 15.2% respectively, indicating significant roles of pH and H2O2concentration in the process of COD removal.
Źródło:
Environment Protection Engineering; 2017, 43, 1; 183-191
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of iron oxide and local cement clay as potential fluoride adsorbents
Autorzy:
Atasoy, A. D.
Yesilnacar, M. I.
Powiązania:
https://bibliotekanauki.pl/articles/207691.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
drinking water purification
membrane process
fluorine
fluor
procesy membranowe
oczyszczanie wody pitnej
Opis:
Health problem from fluoride contaminated water is more acute in rural and small urban communities. Defluoridation of low contaminated water by inexpensive adsorbents is a substantial practice worldwide. In the study, low-cost sorbents have been investigated as replacements for current costly methods of removing the excess fluoride from water below the certain concentration. The adsorption capacity of iron oxide and cement clay in fluoride removal was investigated by the batch method. The equilibrium time was attained in 3 h and 2 h for iron oxide and cement clay, respectively. Optimum adsorbent dosage was found to be 5 g/dm3. Initial fluoride concentrations for the adsorption studies were 1.24 and 12.2 mg/dm3. Fluoride adsorption isotherm fitted well the Freundlich isotherm with the coefficient of determination >0.99 for both adsorbents. The fluoride adsorption capacity of iron oxide was found higher than that of cement clay due to the high surface area and charge of iron oxide. How-ever both substances can reduce F– contamination below the acceptable limits of 1.5 mg/dm3 for less contaminated water.
Źródło:
Environment Protection Engineering; 2017, 43, 2; 109-118
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie membran kompozytowych PAN/PANI do oczyszczania ścieków przemysłowych powstających podczas obróbki metali
Application of PAN/PANI composite membranes in purification of industrial wastewater generated during processing of metals
Autorzy:
Fryczkowska, B.
Przywara, L.
Turek, T.
Powiązania:
https://bibliotekanauki.pl/articles/400323.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki galwanizerskie
Magnafloc 336
proces membranowy
membrany kompozytowe PAN/PANI
galvanic wastewater
membrane process
PAN/PANI composite membranes
Opis:
W pracy zaprezentowano wyniki badań nad zastosowaniem membran kompozytowych z poliakrylonitrylu (PAN) domieszkowanego polianiliną (PANI) do usuwania zanieczyszczeń ze ścieków przemysłowych powstających podczas obróbki metali. Pozyskane z przemysłu ścieki wstępnie podczyszczano poprzez zastosowanie flokulanta Magnafloc®336, po czym roztwór znad osadu wprowadzano do celi ultrafiltracyjnej AMICON (Millipore), zaopatrzonej we wcześniej przygotowaną membranę polimerową. Za pomocą spektrofotometru UV-Vis (HACH) oraz absorpcyjnej spektrometrii atomowej (AAS) oznaczano wskaźniki zanieczyszczenia ścieków przed i po procesach zintegrowanego oczyszczania, celem określenia stopnia usunięcia wybranych jonów ze ścieków. W wyniku prowadzonej flokulacji ze ścieków zostały usunięte fosforany (79%), chlorki (11–14%), siarczany (2–10%) oraz żelazo (36–92%), kobalt (~80%), kadm(~31%) i nikiel (~25%). Natomiast w ciśnieniowym procesie membranowym prawie całkowicie usunięto cynk , miedź i kadm (~100%), żelazo (o kolejne 43–69%) oraz aniony fosforanowe.
The paper presents results of research on the use of composite membranes of polyacrylonitrile (PAN) doped polyaniline (PANI) to remove contaminations of industrial wastewater generated during the processing of metals. Wastewater obtained from industry was pre-treated with the flocculant Magnafloc®336, and then the supernatant solution was introduced into the ultrafiltration cell, AMICON (Millipore) equipped in the previously prepared polymer membrane. Using spectrophotometer UV-Vis (HACH) and atomic absorption spectrometry (AAS) pollution indicators was marked before and after the integrated purification proces, to determine the degree of removal of selected ions from wastewater. As a result of flocculation from wastewater there have been removed phosphates (79%), chlorides (11–14%), sulfates (2–10%) and iron (36–92%), cobalt (~ 80%), cadmium (~ 31% ) and nickel (~ 25%). However, the pressure membrane process almost completely removed zinc, copper and cadmium (~ 100%), iron (by a further 43–69%) and phosphate anions, which was a little.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 2; 21-29
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the most effective operating conditions of membrane bioreactor used to industrial wastewater treatment
Autorzy:
Świerczyńska, A.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/208164.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wastewater treatment
activated sludge process
bioconversion
bioreactors
industrial water treatment
landfill
leachate treatment
water treatment
activated sludge
dairy wastewater
industrial wastewater treatment
membrane bioreactor
municipal landfills
oczyszczalnia ścieków
proces osadu czynnego
biokonwersja
bioreaktory
uzdatnianie wody przemysłowej
uzdatnianie wody
osad czynny
ścieki mleczarskie
oczyszczanie ścieków przemysłowych
bioreaktor membranowy
składowiska odpadów komunalnych
Opis:
The effectiveness of co-treatment of leachates from an old site of municipal landfill with a dairy industry wastewater in a membrane bioreactor has been investigated. The subjects of the study were leachates collected at the municipal landfill in Tychy and dairy wastewaters from Dairy Plant in Bieruń. The determination of the most effective technological parameters of the process, i.e. activated sludge load and its concentration and types of COD fractions in the reactor influent was made. It was shown that the activated sludge load at the level of 0.06 g COD/(gDM·d) was the highest permissible one among all the investigated loads and the process run effectively within the whole investigated range of concentrations of activated sludge in a bioreactor. It was found that in the treated wastewater, the fraction of easily degradable organic compounds was the dominant one.
Źródło:
Environment Protection Engineering; 2015, 41, 1; 41-51
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie arsenu z wody podziemnej w zintegrowanym procesie koagulacja/mikrofiltracja
Arsenic removal in integrated coagulation/microfiltration process
Autorzy:
Bray, R. T.
Powiązania:
https://bibliotekanauki.pl/articles/237341.pdf
Data publikacji:
2013
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
pierwiastek śladowy
proces membranowy
membrany rurowe
water treatment
trace element
membrane process
tubular membranes
Opis:
Przedstawiono wyniki badań przeprowadzonych w skali ułamkowo-technicznej nad zastosowaniem procesu koagulacji zintegrowanej z mikrofiltracją do usuwania arsenu z wody podziemnej zawierającej 40 mgAs/m3, 0,7 gFe/m3 oraz 0,1 gMn/m3. Jako koagulant zastosowano wodny roztwór siarczanu żelaza(III) – PIX 112 w dawkach 0,5÷19gFe/m3. W badaniach wykorzystano rurowe membrany mikrofiltracyjne z PVDF o granicznej rozdzielczości (cut off) 400 kDa. Zastosowano przepływ jednokierunkowy (dead-end) przy ciśnieniu transmembranowym 0,1÷0,2 MPa. Wykazano, że już przy dawce koagulantu około 2,0 gFe/m3 uzyskano usunięcie arsenu do wartości mniejszej niż dopuszczalna w wodzie przeznaczonej do spożycia (10 mgAs/m3), a współczynnik retencji arsenu przekraczał 76 %. Dalsze zwiększanie dawki koagulantu skutkowało tylko niewielkim zmniejszeniem zawartości arsenu w wodzie oczyszczonej. Zawartość związków żelaza w permeacie, w całym zakresie zastosowanych dawek, była śladowa. Usuwaniu arsenu towarzyszyło zmniejszenie intensywności barwy wody, absorbancji w nadfiolecie oraz utlenialności. Badany proces był natomiast nieskuteczny w usuwaniu związków manganu z wody podziemnej.
Pilot plant results of studies on arsenic removal from groundwater that contained 40 mgAs/m3, 0.7 gFe/m3, and 0.1 gMn/m3, using integrated coagulation/microfiltration process were presented. Iron sulfate(III) (PIX 112) water solution was used as coagulant in doses ranging from 0.5 to 19 gFe/m3. For the experimental purposes PVDF tubular microfiltration membrane with cut-off of 400 kDa was used. One direction (dead-end) flow was applied with pressure ranging from 0.1 to 0.2 MPa. It was demonstrated that at coagulant dose of 2.0 gFe/m3 arsenic was brought down to below target value (<10 mgAs/m3), accepted for human consumption, while the retention coefficient exceeded 76%. Further increase in the coagulant dose led to only insignificant reduction in arsenic content in the purified water. In the dose range applied, there was only a trace amount of iron in the permeate. Arsenic removal was accompanied by reduction in water color intensity, UV-absorbance and chemical oxygen demand (COD). The process, however, was not effective for groundwater manganese removal.
Źródło:
Ochrona Środowiska; 2013, 35, 4; 33-37
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie zanieczyszczeń z wód w hybrydowym reaktorze membranowym przy współudziale procesu MIEX®DOC
Removal of contaminants from water in hybrid membrane reactor in cooperation MIEX®DOC process
Autorzy:
Rajca, M.
Powiązania:
https://bibliotekanauki.pl/articles/127542.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
proces MIEX DOC
ultrafiltracja
reaktor membranowy
oczyszczanie wód
MIEX DOC process
ultrafiltration
membrane reactor
water treatment
Opis:
Celem pracy było określenie efektywności usuwania zanieczyszczeń organicznych i nieorganicznych z wody w hybrydowym reaktorze membranowym, w którym realizowano proces wymiany jonowej i ultrafiltracji. W badaniach wykorzystano żywicę MIEX® firmy Orica Watercare oraz ultrafiltracyjny moduł kapilarny zanurzeniowy ZeeWeed 1 (ZW 1), pracujący w podciśnieniu, wykonany z polifluorku winylidenu, firmy GE Power&Water. Zastosowanie wielofunkcyjnego reaktora korzystnie wpływało na efektywność usuwania zanieczyszczeń, uzyskując wodę oczyszczoną wysokiej jakości, a w odniesieniu do procesu ultrafiltracji zminimalizowano problem foulingu membrany.
The aim of this study was to determine the effectiveness of removal of organic and inorganic contaminants from water using hybrid membrane reactor in which ion exchange and ultrafiltration processes were performed. MIEX® resin by Orica Watercare and immersed ultrafiltration polyvinylidene fluoride capillary module ZeeWeed 1 (ZW 1) by GE Power&Water operated at negative pressure were used. The application of multifunctional reactor had a positive effect on the removal of contaminants and enabled the production of high quality water. Additionally, in refer to single stage ultrafiltration it minimalized the occurrence of membrane fouling.
Źródło:
Proceedings of ECOpole; 2013, 7, 1; 393-398
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aquapores in lymnaeid snails
Autorzy:
Pienkowska, J.R.
Tomkowiak, E.
Lesicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/83249.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Mikołaja Kopernika. Wydział Biologii i Ochrony Środowiska. Stowarzyszenie Malakologów Polskich
Tematy:
aquapore
lymnaeid snail
Lymnaea stagnalis
Stagnicola palustris
Catascopia occulta
snail
cell membrane
substance transport
physiological process
aquaporin
Źródło:
Folia Malacologica; 2012, 20, 1
1506-7629
Pojawia się w:
Folia Malacologica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Designing of membrane contactors with cross-counter current flow
Autorzy:
Kołtuniewicz, A.B.
Modelski, S.
Witek, A.
Powiązania:
https://bibliotekanauki.pl/articles/952681.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
membrane contactor
sorption process
integrated processes of separation
designing
surface renewal theory
stycznik membranowy
proces sorpcji
zintegrowany proces separacji
projektowanie
teoria odnowienie powierzchni
Opis:
The knowledge about membrane contactors is growing rapidly but is still insufficient for a reliable designing. This paper presents a new type of membrane contactors that are integrated with one of the following ways of separation by using absorbents, micelles, flocculants, functionalized polymers, molecular imprints, or other methods that are based on aggregation. The article discusses methods for designing multi-stage cascade, usually counter-current. At every stage of this cascade, relevant aggregates are retained by the membrane, while the permeate passes freely through membrane. The process takes place in the membrane boundary layer with a local cross-flow of the permeate and the retentate. So the whole system can be called a cross-counter-current. The process kinetics “k” must be coordinated with the permeate flux “J” and the rate of surface renewal of the sorbent on the membrane surface, s. This can be done by using ordinary back-flushing or relevant hydrodynamic method of sweeping, such as: turbulences, shear stresses or lifting forces. A surface renewal model has been applied to adjust the optimal process conditions to sorbent kinetics. The experimental results confirmed the correctness of the model and its suitability for design of the new type of contactors.
Źródło:
Chemical and Process Engineering; 2012, 33, 4; 573-583
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The characteristics of the possibility of the use of polymer membranes in production of oxygen for energy processes
Charakterystyka możliwości wykorzystania membran polimerowych do produkcji tlenu dla procesów energetycznych
Autorzy:
Kotowicz, J.
Berdowska, S.
Powiązania:
https://bibliotekanauki.pl/articles/172893.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
membrana polimerowa
produkcja tlenu
proces kriogeniczny
metoda hybrydowa
Aspen
polymeric membrane
oxygen production
cryogenic process
hybrid method
Opis:
In this paper, different methods of oxygen production are characterized. The main attention is focused on the use of polymer membranes. Hybrid method is proposed in the process of oxygen production. Membrane is used in the first stage of this method, while in the second one, the cryogenic process is chosen. The calculations of the membrane parameters have been made in Aspen software. The characteristic values for the membrane separation process such as oxygen recovery rate and permeate purity have been determined. Various systems have been analyzed. It has been calculated that energy consumption in the process of cryogenic oxygen production reaches 0.2 kWh/kgO2 or even 0.19 kWh/kgO2 in the membrane process using a vacuum pump, and in the near future, with the improvement of the membrane properties it will be limited to 0.15 kWh/kgO2.
W artykule scharakteryzowano różne metody produkcji tlenu. Główną uwagę skupiono na wykorzystaniu membran polimerowych. W procesie produkcji tlenu zaproponowano metodę hybrydową, w której w pierwszym stopniu stosuje się membranę, zaś w drugim proces kriogeniczny. Obliczenia membran wykonano przy wykorzystaniu programu Aspen. Wyznaczono charakterystyczne wielkości dla procesu separacji membranowej takie jak stopień odzysku tlenu i czystość permeatu. Analizowano różne układy. Obliczono, że przy zastosowaniu pompy próżniowej w procesie membranowym energochłonność kriogenicznego procesu wytwarzania tlenu może wynieść 0,2 kWh/kgO2 lub nawet 0,19 kWh/kgO2, zaś w najbliższej przyszłości wraz z polepszeniem się właściwości membran może być ograniczona do 0,15 kWh/kgO2.
Źródło:
Archiwum Energetyki; 2012, 42, 3/4; 57-70
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies