Advantages of active over passive thermography in terms of applying in medicine
Zalety termografii aktywnej wobec pasywnej z punktu widzenia zastosowań w medycynie
Autorzy:
Wasilewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/270872.pdf
Data publikacji:
2017
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
temperatura stawu
termografia aktywna
termografia pasywna
warunki chłodzenia
joint temperature
active thermography
passive thermography
cooling conditions
Opis:
Infrared thermography (IT) is a remote non-invasive technique of temperature distribution measurement and is widely applied in mechanics, electronics, metallurgy, medicine. Experimental part: 11 healthy volunteers (36% of women), mean age (28.09 (4.46)) were recruited for the study. Firstly, according to passive thermography procedure, thermographic images of left and right hand were taken. Afterwards, active thermography procedure was performed. The protocol included immersing left and right hand in ice water, separately. Results and discussion: Active thermography is to a lesser extent dependent on environmental, individual and technical factors of temperature measurement than passive thermography. Additionally, active thermography enables temperature distribution measurement over the course of time. Conclusions: Active thermography is superior to passive method.
Termografia w podczerwieni (IT) jest bezdotykową, nieinwazyjną techniką pomiaru rozkładu temperatury i jest szeroko stosowana w mechanice, elektronice, metalurgii, medycynie i innych dziedzinach. Część eksperymentalna: 11 zdrowych uczestników (36% kobiet), średni wiek (28,09 (4,46)) zostało zakwalifikowanych do badania. W pierwszej kolejności, zgodnie z procedurą termografii pasywnej, wykonano zdjęcia termowizyjne lewej i prawej dłoni. Następnie przeprowadzono procedurę termografii aktywnej. Protokół uwzględniał schłodzenie oddzielnie lewej i prawej dłoni w wodzie z lodem. Wyniki i ich dyskusja: Termografia aktywna jest w mniejszym stopniu zależna od czynników środowiskowych, indywidualnych oraz technicznych pomiaru temperatury niż metoda pasywna. Dodatkowo termografia aktywna umożliwia pomiar rozkładu temperatury w czasie.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2017, 22, 2; 88-93
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature Distribution in a Steel Beam-to-Column Joint when Exposed to Fire. Part 2: Flange-Plates and Web-Cleats Joint
Autorzy:
Maślak, M.
Suchodoła, M.
Woźniczka, P.
Powiązania:
https://bibliotekanauki.pl/articles/104693.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
beam-to-column joint
flange-plates joint
web-cleats joint
temperature distribution
section factor
numerical simulation
Opis:
In the second part of this paper the temperature distribution is analysed for a thermally uninsulated steel beam-to-column flange-plates and web-cleats joint after 15 minutes of its exposure to a fully developed fire. Two types of such a joint are considered separately, firstly the pure steel connection with a beam and a column evenly heated on all four sides and then the analogous one, but with a massive reinforced concrete floor slab lying on the upper beam flange. In the latter case the joint beam is heated only on three sides. In addition, in each of the analysed joint the beams of two sizes are analysed independently for comparative purposes. Those that are made of the bigger I-section have a more slender web, while the smaller ones are more stocky. However, the smaller I-section heats faster than the bigger one because the section factor calculated for it has a greater value. In general, it can be concluded that in all the joints considered by the authors the steel temperature turned out to be much lower than that measured outside these joints. Moreover, a significant difference is observed in the temperature values identified in the beam web and in the beam flanges. Finally, the temperature distribution obtained from a numerical simulation and identified in the selected cross-sections of the joint beam in the case of a joint with adjacent floor slab is referred to the analogous distribution recommended for use in such circumstances in the standard EN 1993-1-2.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 103-114
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature Distribution in a Steel Beam-to-Column Joint when Exposed to Fire. Part 1: End-Plate Joint
Autorzy:
Maślak, M.
Suchodoła, M.
Woźniczka, P.
Powiązania:
https://bibliotekanauki.pl/articles/105584.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
beam-to-column steel end-plate joint
fire
temperature distribution
joint components
numerical simulation
Opis:
Temperature distribution usually observed in steel beam-to-column end-plate joint after 15 minutes of its standard fire exposure is presented and discussed in detail. Two types of joints are analysed for comparative purposes. The first one is a pure steel connection while the other is covered by a reinforced concrete slab. Numerical simulation of the considered joint heating scenario was performed using the 3D model in the ANSYS environment. Some results were additionally verified by simpler calculations carried out on 2D models using the SAFIR computer program. It is emphasized that due to the local accumulation of many massive steel plates the representative temperature values identified in particular joint components are significantly lower than those which at the same time are measured in beam and column outside the connection. This means that the classic assumption of even temperature over the entire length of all the structural elements of a frame load-bearing structure exposed to fire at any time during such fire, without distinguishing in the formal model any cooler nodal elements, is always safe but very conservative. In addition, as the fire develops the differentiation between the temperature values relating to the beam web and to the beam flanges becomes more visible. This effect is particularly significant in the presence of a massive floor slab adjacent the upper flange of a frame I-beam which effectively cools it.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 25-34
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wytrzymałość połączeń klejowych utwardzanych w podwyższonej temperaturze
Strength of adhesive joints cured in elevated temperature
Autorzy:
Rudawska, A.
Kasperek, E.
Powiązania:
https://bibliotekanauki.pl/articles/278123.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Inżynierii Materiałów Polimerowych i Barwników
Tematy:
połączenie klejowe
wytrzymałość
utwardzanie
temperatura utwardzania
adhesive joint
strength
curing
curing temperature
Opis:
W pracy przedstawiono wybrane zagadnienia związane z wpływem sposobu utwardzania na wytrzymałość połączeń klejowych blach stalowych ocynkowanych. Do wykonania połączeń zastosowano klej epoksydowy dwuskładnikowy Loctite 9497. Podczas utwardzania spoiny klejowej zastosowano dwa warianty utwardzania: utwardzanie jednostopniowe w temperaturze otoczenia oraz dotwardzanie w temperaturze podwyższonej, przy czym temperaturę dotwardzania przyjęto z zakresu 60÷110°C. Zauważono korzystny wpływ dotwardzania w podwyższonej temperaturze na wartość maksymalnych sił przenoszonych przez połączenie klejowe. Największą wytrzymałością charakteryzują się próbki dotwardzanie w temperaturze 110°C oraz dość dużą powtarzalnością uzyskanych wyników badań. W przypadku dotwardzania połączeń klejowych w temperaturze 60°C otrzymano najmniejszą wytrzymałość.
This article presents the selected issues related to the influence of curing methods on the adhesive joints strength of stainless steel sheets. Loctite 9497 the two-component epoxy adhesive was used to prepare adhesive joints. Two variants of curing process were used: single-stage curing in ambient temperature and curing in elevated temperature. From 60°C to 110°C range the elevated temperature was acceptance. A beneficial effect of curing in elevated temperature on the maximum failure force was noted. The greatest strength and a fairly large repeatability of the obtained results are characterized by adhesive joints cured at a 110°C temperature. In the case of cured adhesive joints in 60°C temperature was received the least strength.
Źródło:
Przetwórstwo Tworzyw; 2014, [R.] 20, nr 4 (160), 4 (160); 326-331
1429-0472
Pojawia się w:
Przetwórstwo Tworzyw
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Critical Temperature Evaluation for a Steel Frame with Joint Stiffness Decreasing in Fire
Autorzy:
Maślak, M.
Pazdanowski, M.
Snela, M.
Powiązania:
https://bibliotekanauki.pl/articles/105154.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
steel bearing frame
fire
critical temperature
joint stiffness
moment-rotation relationship
weakest link
Opis:
A procedure to determine the critical temperature of a selected steel frame bearing structure is presented and discussed. This temperature, in case of fully developed fire, when the temperature of the exhaust gasses enveloping the structural members is equalized within the whole fire zone, may be considered as an impartial measure of safety. The obtained result does not depend on the heating progress but only on the static scheme and the load level in the considered structure. The quantitative and qualitative evaluation of the influence the joint stiffness decreasing in fire exerts on the resultant critical temperature constitutes the basic objective of the authors. It has been shown, that proceeding according to the recommended computational procedure does not necessarily result in an estimate fully unambiguous in interpretation. The critical temperature specified in a global mode, for the whole considered frame, is usually associated with a specific component of such frame, interpreted as the so called “weakest link”. Thus local loss of bearing capacity in such element is in this approach equivalent to the total destruction of the whole bearing structure. Indication, which of the components present in the considered frame should be treated as the critical one, because of its behaviour under fire conditions, seems to be a key to the forecast safety level warranted to the users of the structure. The authors show, that this association changes depending on the selected computational method, and this in turn substantially limits the reliability of the obtained estimate.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 91-101
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Relacja moment – obrót w warunkach pożaru dla stalowego węzła rygiel – słup o znanej podatności
Moment – rotation dependence under fire conditions for steel beam-to-column joint with known flexibility
Autorzy:
Maślak, M.
Snela, M.
Powiązania:
https://bibliotekanauki.pl/articles/390989.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
pożar
temperatura
podatność
obrót
węzeł
rygiel
słup
fire
temperature
flexibility
rotation
joint
beam
column
Opis:
Zaprezentowano uproszczony sposób tworzenia krzywych moment – obrót charakteryzujących podatność stalowego węzła rygiel – słup w pożarze rozwiniętym. Kształt poszukiwanej krzywej zmienia się z narastaniem temperatury elementów tworzących węzeł. Krzywą odniesienia jest analogiczna relacja określona w podstawowej sytuacji projektowej, przy pomocy klasycznej metody składnikowej. W pracy proponuje się zastąpienie tej relacji alternatywnymi formułami wynikającymi z zastosowania modelu Richarda – Abbotta lub z wykorzystania podejścia rekomendowanego w PN-EN 1993-1-8. W celu transformacji do warunków pożaru formułę początkową aproksymuje się łamaną, którą następnie przekształca się do postaci wynikowej, zależnej od założonej temperatury elementów stalowych. Dokonuje się tego stosując współczynniki i będące miarą względnej redukcji odpowiednio granicy plastyczności i modułu sprężystości podłużnej stali. W efekcie otrzymuje się pęk charakterystyk opisujących podatność badanego węzła, z których każda odpowiada innej założonej temperaturze materiału.
Simplified methodology helpful in a reliable specification of moment - rotation dependences characterizing the steel beam-to-column joint flexibility under fully developed fire conditions is presented and discussed in detail. The shape of identified dependences changes with the temperature increase of the members connected in the considered joint. The analogous relation, known a priori and determined for examined joint being under persistent design situation, is adopted as the reference dependence specified on the basis of the classical component approach. In the presented paper the alternative calculation technique, recommended by the authors in this field, deals with the replacement of such reference relation by another one resulted from the use of Richard – Abbott formal model. Furthermore, the additional approach, taken from the standard PN-EN 1993-1-8, is examined for comparative purposes. To transform such input dependence, related to the room member temperature, into the case of fully developed fire scenario it is firstly approximated by suitable segmental curve and afterwards the relative reduction ratios referring to the steel elasticity modulus as well as to the steel yield point, the joint is made of, are taken into consideration. As a result, a number of the requested relations is obtained, differentiated dependently on the assumed member temperature.
Źródło:
Budownictwo i Architektura; 2013, 12, 2; 237-244
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ambiguity in determining the critical temperature of a steel sway frame with semi-rigid joints
Niejednoznaczność w wyznaczaniu temperatury krytycznej stalowej ramy przechyłowej z podatnymi węzłami
Autorzy:
Maslak, M.
Pazdanowski, M.
Snela, M.
Powiązania:
https://bibliotekanauki.pl/articles/1849756.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odporność ogniowa
rama stalowa
temperatura krytyczna
węzeł sztywny
węzeł półsztywny
węzeł doczołowy
węzeł belka-słup
fire resistance
steel frame
critical temperature
fully rigid joint
semi rigid joint
end plate joint
beam to column joint
Opis:
The problem of uniqueness and representativeness of steel frame fire resistance assessment is considered in this paper. The thesis, that the selection of analysis method determines the result in both qualitative and quantitative terms is given scrutiny. It is also shown, that the differences between computed values may be significant. The selection of an appropriate computational model for an analysis of this type seems to be especially important, as the possible overestimation of the fire resistance determined during computation is equivalent to an unjustified optimism of the user with respect to the safety level warranted. In the considerations presented here the critical temperature determined for the whole bearing structure is considered as the measure of sought resistance. The determined temperature is associated with the bearing structure reaching the bearing capacity limit state subject to fire conditions, treated as accidental design situation. Two alternative computational methods have been applied during calculations: the first one - classical, based on 1st order statics and using the buckling length concept for members of the considered frame, and the second one - taking account of 2nd order phenomena via simple amplification of the horizontal loads applied to the frame. Special attention has been paid to the influence exerted on the final fire resistance of the considered structure by the real joint rigidity, decreasing with increasing temperature of the structural members. The obtained results differ not only in the value of determined temperature but also in the indicated location of the weakest frame component, determining its safety.
W pracy rozważa się problem jednoznaczności i reprezentatywności oszacowania odporności ogniowej ramy stalowej. Weryfikacji poddano tezę, że wybór metody analizy determinuje uzyskany wynik zarówno pod względem ilościowym jak i jakościowym, a różnice pomiędzy wyliczonymi wartościami mogą okazać się znaczące. Dobór miarodajnego modelu obliczeniowego w tego typu analizie wydaje się być szczególnie ważny, bowiem ewentualne przeszacowanie wyznaczonej z obliczeń odporności jest równoznaczne z nieuzasadnionym optymizmem użytkownika budynku co do gwarantowanego mu poziomu bezpieczeństwa. W prezentowanych rozważaniach miarą poszukiwanej odporności jest temperatura krytyczna specyfikowana dla całego ustroju nośnego. Nie zależy ona od prognozowanego scenariusza rozwoju pożaru i z tego względu może zostać uznana za pewnego rodzaju charakterystykę samej konstrukcji. Wyznaczana temperatura kojarzona jest z osiągnięciem przez ustrój nośny stanu granicznego nośności w warunkach pożaru traktowanego jako wyjątkowa sytuacja projektowa. Nie oznacza to jednak natychmiastowej katastrofy badanej konstrukcji ale jedynie sytuację, gdy prawdopodobieństwo tego rodzaju zdarzenia staje się już na tyle duże że nie może być dalej akceptowane. Do szczegółowej analizy wykorzystano dwie alternatywne procedury obliczeń: pierwszą - opartą o klasyczną statykę pierwszego rzędu, z wykorzystaniem koncepcji długości wyboczeniowej elementów badanej ramy, i drugą - uwzględniającą efekty drugiego rzędu przez prostą amplifikację przyłożonego do tej ramy obciążenia poziomego.
Źródło:
Archives of Civil Engineering; 2020, 66, 4; 611-632
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental studies of static and dynamic steel arch support load capacity and sliding joint temperature parameters during yielding
Autorzy:
Pytlik, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/1853806.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
nośność statyczna
wyrobisko
podpora stalowa
yielding steel arch support
support shackle torque
static and dynamic load capacity
support work
arch acceleration in sliding joints
joint sparking and heating temperature during yielding
Opis:
Difficult geological and mining conditions as well as great stresses in the rock mass result in significant deformations of the rocks that surround the workings and also lead to the occurrence of tremors and rock bursts. Yielding steel arch support has been utilised in the face of hard coal extraction under difficult conditions for many years, both in Poland and abroad. A significant improvement in maintaining gallery working stability is achieved by increasing the yielding support load capacity and work through bolting; however, the use of rock bolts is often limited due to factors such as weak roof rock, significant rock mass fracturing, water accumulation, etc. This is why research and design efforts continue in order to increase yielding steel arch support resistance to both static and dynamic loads. Currently, the most commonly employed type of yielding steel arch support is a support system with frames constructed from overlapping steel arches coupled by shackles. The yield of the steel frame is accomplished by means of sliding joints constructed from sections of various profiles (e.g. V, TH or U-type), which slip after the friction force is exceeded; this force is primarily dependent on the type of shackles and the torque of the shackle screw nuts. This article presents the static bench testing results of ŁP10/V36/4/A, ŁP10/V32/4/A and ŁP10/V29/4/A yielding steel arch support systems formed from S480W and S560W steel with increased mechanical properties. The tests were conducted using 2 and 3 shackles in the joint, which made it possible to compare the load capacities, work values and characteristics of various types of support. The following shackle screw torques were used for the tests: Md = 500 Nm – for shackles utilised in the support constructed from V32 and V36 sections. Md = 400 Nm – for shackles utilised in the support constructed from V29 sections. The shackle screw torques used during the tests were greater compared to the currently utilised standard shackle screw torques within the range of Md = 350-450 Nm. Dynamic testing of the sliding joints constructed from V32 section with 2 and 3 shackles was also performed. The SD32/36W shackles utilised during the tests were produced in the reinforced versions and manufactured using S480W steel. Since comparative testing of a rock bolt-reinforced steel arch support system revealed that the bolts would undergo failure at the point of the support yield, a decision was made to investigate the character of the dynamics of this phenomenon. Consequently, this article also presents unique measurement results for top section acceleration values registered in the joints during the conduction of support tests at fullscale.Filming the yield in the joint using high-speed video and thermal cameras made it possible to register the dynamic characteristics of the joint heating process at the arch contact point as well as the mechanical sparks that accompanied it. Considering that these phenomena have thus far been poorly understood, recognising their significance is of great importance from the perspective of occupational safety under the conditions of an explosive atmosphere, especially in the light of the requirements of the new standard EN ISO 80079-36:2016, harmonised with the ATEX directive.
Źródło:
Archives of Mining Sciences; 2020, 65, 3; 469-491
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane problemy długotrwałej eksploatacji połączeń klejowych
The adhesive joint - the chosen problems of static service life
Autorzy:
Rośkowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/256941.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
klejenie
połączenie klejowe
statyczna trwałość czasowa
temperatura
modyfikowanie spoiny
adhesive-bonded joint
static service life
temperature
Opis:
W pracy przedstawiono wybrane wyniki analizy doświadczalnej dotyczącej statycznej trwałości czasowej spoin klejowych obciążonych długotrwale w podwyższonej temperaturze. W badaniach wykorzystano kleje epoksydowe oparte na żywicach Epidian 5 i Epidian 57 oraz klejowe kompozyty regeneracyjne z wypełniaczami metalicznymi. Spoiny połączeń klejowych poddano modyfikacji. Stwierdzono, że modyfikowanie spoiny klejowej tkaniną szklaną, elektrokorundem i wypełniaczami metalicznymi istotnie poprawia statyczną trwałość czasową połączenia w podwyższonej temperaturze.
In the paper there are presented some experimental results concerning static service life of adhesive-bonded joint loaded long-lasting at elevated temperature. Epoxy adhesives based on Epidian 5, Epidian 57 and adhesively regeneration composites with metallic filler, on account of them universality, were chosen for experimental study. The adhesive-bonded joints were modified. It has been found, that modifying adhesive-bonded joint glass fabric, alundum and metallic filler improving significantly static service life of the adhesive joint at elevated temperature.
Źródło:
Problemy Eksploatacji; 2006, 3; 91-105
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An analysis of the resistance of an extended end-plate beam-to-beam connection subjected to tension in fire conditions
Autorzy:
Słowikowska, Alina
Polus, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/390133.pdf
Data publikacji:
2019
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
beam-to-beam connection
fire resistance
steel joint
critical temperature
połączenie belka-belka
odporność ogniowa
złącze stalowe
temperatura krytyczna
Opis:
This paper presents an analysis of the fire resistance of a steel joint subject-ed to tension. The authors of this article used prescriptive rules and simple calculation models to present an impact of the value of the load on the fire resistance of the connection. Designers often evaluate the critical temperature and fire resistance time of steel elements. However, they neglect the evaluation of the above-mentioned values for steel connections. In this article a simple engineering method was used to calculate the fire resistance of the joint.
Źródło:
Budownictwo i Architektura; 2019, 18, 1; 81-88
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerically Simulated Structural Response of a Bearing Steel Frame with Joints of Varying Stiffness to Fully Developed Fire Conditions
Symulowana numerycznie reakcja na pożar rozwinięty stalowej ramy nośnej z węzłami o różnej sztywności
Autorzy:
Maślak, Mariusz
Woźniczka, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2060841.pdf
Data publikacji:
2019
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
steel frame
fire
temperature
joint susceptibility
displacement
redistribution of internal forces
rama stalowa
pożar
temperatura
podatność węzłów
przemieszczenie
redystrybucja sił wewnętrznych
Opis:
Aim: This paper examines the responses of load-bearing steel frames to direct fire exposure and the associated impact of the monotonically increasing temperature of its components. For comparative purposes, the authors analysed in detail specific frames with beam-to-column joints differing in rigidity. Depending on whether there are stiffening ribs present and, if so, on where they are located, the fire resistance of the considered structural component is determined by the actual damage patterns. These can be manifested as local instability in the column web or as damage to the column flange or beam flange. The design of the joint is also one of the factors determining the redistribution of internal forces generated in the frame components when subjected to fire conditions. Methods: The authors identified, discussed and compared the dependencies determining the relationships between the temperature of the frame components, and the bending moments and axial forces induced in these components during a fire. These relationships were identified through a detailed analysis of a numerical example, in which the fire behaviour of three similar steel frames, differing in terms of their beam-to-column joint rigidity, was examined. In the first analysed case, a joint without any ribbing was examined, in the second case, a joint with horizontal ribs, and in the third case, a joint with horizontal and diagonal ribs. The relationships listed above are accompanied by corresponding the relationships specifying the dependencies between steel temperature and frame beam deflection. In addition, the analysis considers flexible supports with different rigidity to model the resistance of the columns to horizontal joint displacement. Results: It has been shown that the analysed types of the examined frame exhibit substantial differences in their predicted structural responses if the joints used in them and exposed to fire differ in rigidity. The identification of these differences and their qualitative and quantitative description constitute the main objective of this work. Conclusions: Frame behaviour under fire conditions is determined not only by frame geometry and the size of its structural members, designed to be able to fully bear their respective loads, but also, to the same extent, by the susceptibility to deformation of the bearing structure itself and the joints connecting the component structural members.
Cel: W artykule autorzy analizowali sposób reakcji stalowej ramy nośnej na bezpośrednią ekspozycję ogniową oraz towarzyszący jej monotoniczny wzrost temperatury elementów badanej ramy. W celach porównawczych rozpatrzono ramy z węzłami typu rygiel – słup o różnym stopniu podatności. W zależności od tego, czy węzeł jest użebrowany i jak ewentualne żebra są rozmieszczone, o odporności ogniowej badanego ustroju nośnego decyduje inny sposób zniszczenia. Może to być zarówno lokalna utrata stateczności środnika słupa, jak i zniszczenie pasa rygla lub pasa słupa. Sposób konstrukcji węzła determinuje również schemat redystrybucji sił wewnętrznych generowanych w warunkach pożaru w elementach ramy. Metody: W pracy zidentyfikowano i porównano odpowiednie zależności specyfikujące relacje pomiędzy temperaturą elementów ramy a indukowanymi w tych elementach momentem zginającym i siłami osiowymi. Zależności te uzyskano po szczegółowej analizie przykładu numerycznego, w którym badano zachowanie w warunkach pożaru trzech odpowiadających sobie ram stalowych, przy czym w każdej z tych ram zastosowano węzły o innej sztywności. W pierwszym przypadku były to węzły z nieużebrowanym środnikiem, w drugim – ze środnikiem użebrowanym jedynie przez wykorzystanie żeber poziomych, w trzecim natomiast – węzły z żebrami poziomymi i żebrem ukośnym. W analizie dodatkowo zróżnicowano sztywność podparcia sprężystego modelującego podatność słupów ramy na poziome przemieszczenie węzłów. Wyniki: Uzyskane wyniki potwierdziły oczekiwany wniosek: w początkowej fazie pożaru w ryglach ramy dominuje ściskanie, co przekłada się na rozpychanie węzłów. Ze wzrostem temperatury elementów coraz większego znaczenia nabiera jednak wpływ narastającego ugięcia rygla, co w efekcie generuje postępujący zanik osiowej siły ściskającej. To z kolei powoduje ściąganie węzłów ramy do jej wnętrza. Tego typu ogólny schemat zachowania się ramy w pożarze ma jednak zasadniczo różny przebieg, jeśli tylko węzły ramy wykazują różną sztywność. Specyfikacja tych różnic oraz ich jakościowy i ilościowy opis są podstawowym celem prezentowanej pracy. Wnioski: Zachowanie się w pożarze rozwiniętym stalowej ramy nośnej warunkowane jest przez jej geometrię oraz rozmiary kształtujących ją elementów konstrukcyjnych o przekrojach zaprojektowanych tak, aby elementy te były zdolne do przenoszenia przyłożonych do nich obciążeń. W równym stopniu istotna jest podatność na deformacje zarówno samego ustroju nośnego, jak i poszczególnych węzłów scalających ten ustrój.
Źródło:
Safety and Fire Technology; 2019, 53, 1; 32--45
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Four-parameter electromagnetic method for determining the parameters of brewery effluents
Autorzy:
Sebko, V. V.
Pyrozhenko, Ye. V.
Zashchepkina, N. M.
Zdorenko, V. G.
Markina, O. M.
Powiązania:
https://bibliotekanauki.pl/articles/2201046.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
four-parameter electromagnetic method
brewery effluents
magnetic flux probe
MFP
conversion function
joint measurement
electrical conductivity
relative permittivity
density
temperature
metoda elektromagnetyczna
ścieki
strumień magnetyczny
funkcja konwersji
przewodność elektryczna
względna przenikalność elektryczna
gęstość
temperatura
Opis:
Purpose of the article is to study a four-parameter electromagnetic method for joint measurements of electrical resistivity k, relative permittivity εr, temperature t and density ρ of samples of acidic, alkaline and average effluents from a microbrewery based on a magnetic flux probe (MFP), which considers the influence of informative parameters of beer effluents on the components of the amplitude and phase signals of a multiparameter device. Design/methodology/approach The implementation of the four-parameter method is carried out on the basis of the dependences G1 = f (A1) and G2 = f (A2) at two frequencies of the electromagnetic field f0 and f1 for acid, alkaline and average effluent and allows you to jointly determine the four parameters of effluent samples with the same converter in the same control area. The proposed method makes it possible to improve the accuracy of identifying effluent samples since the obtained multiparameter information makes it possible to determine the nature and properties of effluent samples using only one transducer with certain physical characteristics. The research results lead to the expansion of the technical capabilities of electromagnetic measurement methods, as well as to an increase in the metrological characteristics of electromagnetic transducers and an increase in the accuracy of measuring the parameters of effluent samples compared to reference methods and measuring instruments. Thus, the implementation of this approach contributes to the prediction and prevention of the reasons for the deviation of beer effluent samples from the specified indicators of environmental safety. Findings The universal conversion functions MFP have been established, connecting the amplitude and phase components of the converter signals with the parameters k, εr, t and ρ of acidic, alkaline and average effluents. Based on the universal transformation functions G1 = f (A1) and G2 = f (A2), a four-parameter electromagnetic method for joint measurements of electrical resistivity k, relative permittivity εr, temperature t and density ρ of acidic, alkaline, and average effluents from breweries has been developed. When conducting research at two close frequencies of the electromagnetic field f0 = 20.3 MHz and f1 = 22 MHz, algorithms were obtained for measuring and calculating procedures for determining k, εr, t and ρ for samples of acidic, alkaline and average effluents from the brewing industry. Research limitations/implications Research perspectives consist in the creation of automated systems for multiparameter measuring control of the physicochemical characteristics of acidic and alkaline effluent from food and processing industries based on the immersed electromagnetic transducer. Based on the data obtained using informative methods to measure the parameters of effluent samples, an integrated method for treating beer effluents of various compositions will be proposed. At the same time, the scheme of the integrated treatment method should include a filter that provides the introduction of a magnetic fluid and a separation device that allows us to remove a fraction, including pollution in itself. Practical implications Is that the proposed four-parameter electromagnetic method makes it possible to determine to what composition the controlled samples of wastewater should be attributed (acidic or alkaline). It, in turn, makes it possible to choose a rational method for treating beer effluents and to prevent the reasons for the deviation of effluent samples from the environmental safety indicators set by the standards. Originality/value of the article is the research related to the expansion of the functional and technical capabilities of the electromagnetic two-frequency transducer MFP through the implementation of a four-parameter electromagnetic method of joint measurements of electrical resistivity k, relative permittivity εr, temperature t and density ρ of acidic, alkaline and average effluents from breweries. The universal transformation functions G1 = f (A1) and G2 = f (A2) found in the work at two close magnetic field frequencies, f0 = 20.3 MHz and f1 = 22 MHz, make it possible to control four physicochemical parameters of acidic, alkaline and average wastewater at the same time by the same MFP. An algorithm has been developed for determining the signal components of a two-frequency thermal MFP, the ranges of which correspond to the ranges of changes in electrical resistivity k, relative permittivity εr, temperature t and density ρ of acidic, alkaline, and average brewery effluents. The basic relations that describe the two-frequency four-parameter electromagnetic method of joint measurements of the physicochemical parameters of acidic, alkaline and averaged beer effluents have been obtained.
Źródło:
Journal of Achievements in Materials and Manufacturing Engineering; 2022, 113, 2; 49--64
1734-8412
Pojawia się w:
Journal of Achievements in Materials and Manufacturing Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies