Temperature Distribution in a Steel Beam-to-Column Joint when Exposed to Fire. Part 1: End-Plate Joint

Tytuł:
Temperature Distribution in a Steel Beam-to-Column Joint when Exposed to Fire. Part 1: End-Plate Joint
Autorzy:
Maślak, M.
Suchodoła, M.
Woźniczka, P.
Powiązania:
https://bibliotekanauki.pl/articles/105584.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
beam-to-column steel end-plate joint
fire
temperature distribution
joint components
numerical simulation
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 25-34
2300-5130
2300-8903
Język:
angielski
Prawa:
CC BY-NC-ND: Creative Commons Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 PL
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
Temperature distribution usually observed in steel beam-to-column end-plate joint after 15 minutes of its standard fire exposure is presented and discussed in detail. Two types of joints are analysed for comparative purposes. The first one is a pure steel connection while the other is covered by a reinforced concrete slab. Numerical simulation of the considered joint heating scenario was performed using the 3D model in the ANSYS environment. Some results were additionally verified by simpler calculations carried out on 2D models using the SAFIR computer program. It is emphasized that due to the local accumulation of many massive steel plates the representative temperature values identified in particular joint components are significantly lower than those which at the same time are measured in beam and column outside the connection. This means that the classic assumption of even temperature over the entire length of all the structural elements of a frame load-bearing structure exposed to fire at any time during such fire, without distinguishing in the formal model any cooler nodal elements, is always safe but very conservative. In addition, as the fire develops the differentiation between the temperature values relating to the beam web and to the beam flanges becomes more visible. This effect is particularly significant in the presence of a massive floor slab adjacent the upper flange of a frame I-beam which effectively cools it.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies