Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "joint analysis" wg kryterium: Temat


Tytuł:
Joint Factor Analysis of Channel Mismatch in Whispering Speaker Verification
Autorzy:
Lv, G
Zhao, H.
Powiązania:
https://bibliotekanauki.pl/articles/176713.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
joint factor analysis
whisper
speaker verification
Opis:
A speaker recognition system based on joint factor analysis (JFA) is proposed to improve whisper- ing speakers’ recognition rate under channel mismatch. The system estimated separately the eigenvoice and the eigenchannel before calculating the corresponding speaker and the channel factors. Finally, a channel-free speaker model was built to describe accurately a speaker using model compensation. The test results from the whispered speech databases obtained under eight different channels showed that the correct recognition rate of a recognition system based on JFA was higher than that of the Gaussian Mixture Model–Universal Background Model. In particular, the recognition rate in cellphone channel tests increased significantly.
Źródło:
Archives of Acoustics; 2012, 37, 4; 555-559
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A platform for joint analysis of biosignals ensembles in real-time using FPGA
Platforma do analizy całości biosygnałów za pomocą FPGA
Autorzy:
Mierzejewski, K.
Véjar, A.
Powiązania:
https://bibliotekanauki.pl/articles/261470.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
biosignals
joint analysis
mutual information
DSP
FPGA
biosygnały
zintegrowana analiza
informacja wzajemna
Cyfrowe Przetwarzanie Sygnałów
programowalne układy cyfrowe
Opis:
We present the design of a platform for acquisition and digital processing of biosignals. The objective of this platform is to process biosignals in real-time to obtain quantitative indicators for joint analysis of biosignals ensembles. An important indicator of non-linear dependence between signals is the mutual information. The estimation of the mutual information between signals is time- and resource-consuming when using standard software implementations on normal computers. To circumvent the calculation limitations on standard software implementations we use a reconfigurable computing unit of type FPGA, were the calculation of mutual information is specified in hardware.
Przedstawiamy projekt platformy służącej do pozyskiwania i cyfrowej obróbki biosygnałów. Jej zadaniem jest przetwarzanie biosygnałów w czasie rzeczywistym w celu uzyskania wskaźników ilościowych dla zintegrowanej analizy zespółów biosygnałów. Ważnym wskaźnikiem nieliniowej zależności pomiędzy sygnałami jest informacja wzajemna. Jej oszacowanie pomiędzy sygnałami przy użyciu standardowego oprogramowania na zwykłych komputerach jest mało wydajne i czasochłonne. Aby obejść ograniczenia narzucone przez narzędzia zwykle wykorzystywane w tym celu, zastosowano rekonfigurowalną jednostkę typu FPGA, w której obliczenia informacji wzajemnej są określone.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2016, 22, 4; 253-260
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Joint Regression Analysis applied to genotype stability evaluation over years
Zastosowanie analizy regresji łącznej do badania stabilności genotypów w doświadczeniach wieloletnich
Autorzy:
Oliveira, Amílcar
Oliveira, Teresa
Mejza, Stanisław
Mexia, João T.
Powiązania:
https://bibliotekanauki.pl/articles/41512366.pdf
Data publikacji:
2008
Wydawca:
Instytut Hodowli i Aklimatyzacji Roślin
Tematy:
analiza regresji łącznej
owies
stabilność genotypów
genotype stability
joint regression analysis
oat
Opis:
Most genotype differences connected with yield stability are due to genotype environment interaction. The presence and dimension of this interaction are the factors that determine the performance of genotypes in distinct environments. The environmental factors, like annual rainfall, temperature, diseases or soil fertility, can only explain part of this interaction. Many statistical tools have been developed with the aim to explain the information contained in the GE interaction data matrix. In our work we use the Joint Regression Analysis (JRA), the Zig-Zag Algorithm to estimate the regression coefficients and the multiple comparison tests of Scheffé, Tukey and Bonferroni. We point out not just the limitations of the JRA when used year by year, but also genotype selection advantage from general JRA over years. Data of the Portuguese Plant Breeding Board were used to carry the year and over years analyses of yielding stability of 22 different genotypes of oat (Avena sativa L.) at six different locations in the years 2002, 2003 and 2004.
Interakcja genotypowo-środowiskowa jest jednym z głównych źródeł różnic w plonowaniu odmian. Istnienie i zakres interakcji determinuje przydatność odmian w różnych środowiskach. Częściowo możemy ją wyjaśnić poprzez niektóre cechy charakteryzujące środowisko takie jak np.: roczna wielkość opadów, temperatura powietrza, częstość występowania chorób, żyzność gleby. W celu wyjaśnienia interakcji genotypowo-środowiskowej wykorzystujemy w pracy informację zawartą w dwuwymiarowej tabeli danych, stosując przy tym następujące metody statystyczne: analiza regresji łącznej, algorytm naprzemienny Zig-Zag, estymacja parametrów równań regresji oraz testy jednoczesne Scheffego, Tukeya i Bonferroniego. Ponadto dyskutujemy użyteczność metody regresji łącznej do selekcji odmian w doświadczeniach pojedynczych oraz w doświadczeniach wielokrotnych i wieloletnich. Rozważania teoretyczne ilustrujemy danymi pochodzącymi z Portugalskiej Sekcji Hodowli Roślin. Dane dotyczą badania stabilności plonu 22 genotypów owsa (Avena sativa L.) na podstawie doświadczeń przeprowadzonych w sześciu miejscowościach w latach 2002, 2003 i 2004.
Źródło:
Biuletyn Instytutu Hodowli i Aklimatyzacji Roślin; 2008, 250; 225-235
0373-7837
2657-8913
Pojawia się w:
Biuletyn Instytutu Hodowli i Aklimatyzacji Roślin
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie krótkoczasowej analizy częstotliwościowej do wyznaczenia częstotliwości wymuszeń odrzutowego silnika lotniczego na stanowisku badawczym
Application of short time-frequency analysis to determine the extortion frequency of a jet aircraft engine on a test bench
Autorzy:
Szymański, G. M.
Misztal, A.
Misztal, W.
Powiązania:
https://bibliotekanauki.pl/articles/310433.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
JTFA
Joint Time Frequency Analysis
analiza częstotliwościowa drgań
analiza czasowo-częstotliwościowa
analiza drgań silnika odrzutowego
silnik odrzutowy
Joint Time-Frequency Analysis
frequency analysis of vibrations
jet engine
Opis:
Diagnostyka silników spalinowych w tym odrzutowych bazuje na metodach wykorzystujących procesy robocze oraz procesy resztkowe tj. drgania, hałas, procesy termiczne, elektryczne i inne. Na podstawie wyników badań procesów roboczych można wnioskować o ogólnym stanie technicznym silnika, natomiast procesy resztkowe niosą informacje o stanie poszczególnych podzespołów i par kinematycznych. Dlatego procesy resztkowe wykorzystuje się, jako autonomiczne lub wspomagające inne metody diagnostyczne. Wszystkie metody oparte na analizie zmian drgań i hałasu dla określenia stanu technicznego obiektu noszą nazwę diagnostyki wibroakustycznej. W pracach dotyczących diagnostyki wibroakustycznej silników, najczęściej pomija się zagadnienia związane z problemem wyboru pasma pomiarowego oraz określenia parametrów diagnostycznych zawierających istotne informacje o stanie silnika. W artykule przedstawiono metodę separacji składowych kinematycznych sygnału drgań z wykorzystaniem technik Joint Time Frequency Analysis (JTFA).
The diagnostic testing of internal combustion engine can be made by using working processes and methods which take advantage of leftover processes (vibration, noise, thermic processes, electric and other). Working processes give information about general condition of internal combustion engine. Leftover processes give information about condition of particular subassemblies and kinematic couples; hence they are used as autonomous processes or as processes supporting other diagnostic methods. Methods based on analysis of vibrations and noise changes to determine technical condition of object are named as vibroacoustic diagnostics. In papers about vibroacoustic diagnostics of engine, problems connected with difficulty to select frequency band and to define diagnostic parameters containing essential information about engine’s condition, are most often omitted. This article describes the method of separation of kinematic components of vibration signal using the technique of Joint Time Frequency Analysis (Jtfa).
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 12; 1328-1332, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computer Aided Design and Structural Analysis of the Endoprosthesis of the Knee Joint
Autorzy:
Zubrzycki, J.
Karpiński, R.
Górniak, B.
Powiązania:
https://bibliotekanauki.pl/articles/118225.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
knee joint
endoprosthesis
finite elements analysis
Opis:
The paper presents results of the preliminary structural analysis of model of the endoprosthesis of the knee joint. Basics of anatomy and biomechanics of the knee joint were introduced. Based on data from computed tomography, the model of knee joint was constructed. The prototype of the endoprosthesis of the knee joint was designed. After determining physical properties of structural materials, the Finite Elements Analysis of the model was conducted under various load conditions. Finally the results of analysis are presented.
Źródło:
Applied Computer Science; 2016, 12, 2; 84-95
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinematyczna analiza chodu kobiet chodzących w obuwiu na wysokim obcasie
Kinematic assessment of women’s gait in high-heeledshoes
Autorzy:
Zostawa, Paweł
Uścinowicz, Natalia
Klich, Sebastian
Zostawa, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/437710.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Rzeszowski. Wydawnictwo Uniwersytetu Rzeszowskiego
Tematy:
analiza ruchu
staw śródstopno-paliczkowy
staw skokowy
stopa, obuwie
move analysis metatarsal-phalangeal joint
ankle
foot
footwear
Opis:
Wstęp. U 60% kobiet w wieku 20-23 lata statystycznie występują zaburzenia w obrębie narządu ruchu, a zwłaszcza stóp. Kobiety często chodzące w obuwiu na wysokim obcasie narażane są na dużo większe przeciążenia układu ruchu, niż kobiety noszące buty na płaskiej podeszwie. Celem pracy była ocena parametrów biokinematycznych stawów śródstopno- paliczkowych oraz stawu skokowego górnego kobiet poruszających się w obuwiu na wysokim obcasie. Materiał i metody. Badania przeprowadzono u 43 kobiet w wieku (22±2,1 lat). W skład grupy badanej wchodziły kobiety, które deklarowały regularne chodzenie w obuwiu na wysokim obcasie. Grupę kontrolną tworzyły kobiety, które sporadycznie chodziły w tym rodzaju obuwia. Do przeprowadzenia badań wykorzystano system analizy ruchu BTS Smart-E oraz zmodyfikowany protokół (Heyes-Davis) uwzględniający kąt w stawach śródstopno-paliczkowych oraz stawie skokowym górnym. Próby pomiarowe były wykonywane bez obuwia. Wyniki. Wartość kąta w stawach śródstopno-paliczkowych w badaniu statycznym (P1) wyniosła 153,3o (grupa A) oraz 152,3o (grupa B), natomiast w momencie pierwszego kontaktu pięty z podłożem (P2)149,4o oraz 149,4o(p<0,05). Podczas kontaktu głowy kości śródstopia (P3) wartość kątowa wyniosła 176,1o, natomiast w grupie kontrolnej 168,6o (p<0,05). W momencie kontaktu palucha z podłożem (P4) kąt wyniósł 176,5o oraz 169,2 (p<0,05). Natomiast w chwili braku kontaktu z podłożem (P5) wartości wynosiły odpowiednio dla grupy A 150,5o, a dla grupy B 138,7o (p<0,05). Wnioski. Długotrwałe chodzenie w obuwiu na wysokim obcasie powoduje powstawanie utrwalonych zmian kinematyki chodu, co ukazane zostało poprzez zmniejszenie się wartości kątowych wyprostu w stawach śródstopno-paliczkowych oraz zwiększenie się w stawie skokowym górnym.
Introduction. Statistically, among 60 percent of women of age between 20-23, a disorder in the locomotor system, especially in the case of feet, can be observed. Women who frequently walk in a high-heeled footwear are at a much higher risk of overstraining their locomotor systems, than women who wear flat-sole shoes. The aim of the work was the assessment of the biokinematic parameters of metatarsal and phalangeal joints, as well as of the top ankle joints among women who walk in a high-heeled footwear. Material and methods. The research was carried out on 43 women being 22±2,1 years old. The examined group consisted of women who declared to regularly walk in a high-heeled footwear. The control group included women who sporadically walk in this type of shoes. In order to carry out the research, the motion analysis system BTS Smart-E and the modified protocol (Heyes-Davis), which took into account the angle in metatarsal and phalangeal joints and in the top ankle joint, were used. The measurements were conducted without the footwear. Results. The angular value in the statistical examination (P1) in metatarsal and phalangeal joints amounted to 153,3o (group A) and 152,3o (group B), whereas at the moment of the first contact of a heel with the ground - (P2)149,4o and 149,4o (p<0,05). Upon the contact of the head of metatarsal (P3), the angle value amounted to 176,1o, whereas in the control group – 168,6o (p<0,05). Upon the toe’s contact with the ground (P4), the angle amounted to 176,5o and 169,2 (p<0,05). At the moment when there was no contact with the ground (P5), the values amounted respectively to: group A – 150,5o, and for group B – 138,7o (p<0,05). Conclusions. Walking in a high-heeled footwear for an extended amount of time results in permanent changes in gait kinetics, which was demonstrated through the decrease in the extension angle values in metatarsal and phalangeal joints, as well as through the increase in the top ankle joints. Słowa klucze: analiza ruchu, staw śródstopno-paliczkowy, staw skokowy, stopa, obuwie
Źródło:
Medical Review; 2014, 3; 216-223
2450-6761
Pojawia się w:
Medical Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of High-Resolution Mechanical Spectroscopy, HRMS: Status and Perspectives. HRMS Coupled with a Laser Dilatometer
Powstanie i rozwój wysokorozdzielczej spektroskopii mechanicznej HRMS - stan obecny i perspektywy. hrms sprzężony z dylatometrem laserowym
Autorzy:
Magalas, L. B.
Powiązania:
https://bibliotekanauki.pl/articles/352212.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mechanical spectroscopy
internal friction
elastic modulus
noise
Fourier transform
Hilbert transform
joint-time frequency analysis
dilatometry
spektroskopia mechaniczna
tarcie wewnętrzne
moduł sprężystości
szumy
transformaty Fouriera
transformaty Hilberta
analiza częstotliwości joint-time
dylatometr
Opis:
Recent achievements in the development of low-frequency high-resolution mechanical spectroscopy (HRMS) are briefly reported. It is demonstrated that extremely low values of the loss angle, ϕ, (tanϕb = 1×10−5) can be measured as a function of frequency, and the precision in estimation of the dynamic modulus is better than 1×10−5 in arbitrary units. Three conditions must be fulfilled to obtain high resolution in subresonant and resonant mechanical loss measurements: (1) noise in stress and elastic strain signals must be lower than 70 dB, (2) high quality of stress and strain signals must be tested both in the frequency- and time-domains, and (3) the estimation of the mechanical loss and modulus must be verified by at least two different computing methods operating in the frequency- and time-domains. It is concluded that phase measurements in the subresonant domain are no longer determined by precision in estimation of the loss angle. Recent developments in high-resolution resonant mechanical loss measurements stem from the application of advanced nonparametric and parametric computing methods and algorithms to estimate the logarithmic decrement and the elastic modulus from exponentially damped free decaying oscillations embedded in experimental noise. It is emphasized that HRMS takes into account the presence of noise in the stress and strain signals, which has not yet been addressed in the literature. The coupling of a low-frequency mechanical spectrometer with an in-situ laser dilatometer is suggested as a new perspective research area in Materials Science.
W pracy przedstawiono najnowsze osiągnięcia związane z powstaniem i rozwojem niskoczęstotliwościowej wysokorozdzielczej spektroskopii mechanicznej, HRMS. Wykazano, że możliwym jest pomiar skrajnie niskich wartości kąta strat ϕ, (tanϕb = 1×10−5) mierzonych w funkcji częstotliwości, zaś dokładność pomiaru dynamicznego modułu sprężystości jest lepsza niż 1×10−5, w jednostkach względnych. Do uzyskania wysokiej rozdzielczości w zakresie subrezonansowej i rezonansowej spektroskopii mechanicznej koniecznym jest spełnienie trzech warunków: (1) szum w sygnałach naprężeń i odkształceń sprężystych musi być bardzo niski, tzn. poniżej poziomu 70 dB, (2) sygnały naprężeń i odkształceń sprężystych muszą być wysokiej jakości i muszą przejść stosowne testy zarówno w dziedzinie częstotliwości, jak i czasu, (3) obliczone wartości strat mechanicznych i modułu sprężystości muszą być zweryfikowane przez co najmniej dwie różne metody obliczeń prowadzone w dziedzinie częstotliwości i czasu. Jednym z najważniejszych wniosków jest stwierdzenie, że pomiary różnic w fazie pomiędzy sygnałami naprężenia i odkształcenia sprężystego w zakresie subrezonansowym, nie są zdeterminowane, jak dotychczas twierdzono, przez ograniczenia w dokładności obliczeń kąta strat. Najnowsze osiągnięcia uzyskane w rozwoju wysokorozdzielczej rezonansowej spektroskopii mechanicznej wynikają z zastosowania nowych zaawansowanych nieparametrycznych i parametrycznych metod obliczeń i algorytmów do estymacji logarytmicznego dekrementu tłumienia oraz modułu sprężystości z wykładniczo tłumionych swobodnie zanikających oscylacji zawierających szum eksperymentalny. W pracy podkreślono, że wysokorozdzielcza spektroskopia mechaniczna HRMS uwzględnia obecność szumu w sygnałach naprężeń i odkształceń, która dotychczas nie była brana pod uwagę w literaturze światowej. Wykazano również, że połączenie niskoczęstotliwościowego spektrometru mechanicznego z in-situ dylatometrem laserowym w jednym urządzeniu badawczym otwiera nowe możliwości poznawcze w zakresie inżynierii materiałowej.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3A; 2069-2076
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja najsłabszego ogniwa w modelowaniu trwałości zmęczeniowej złączy spawanych
Application of the weakest link concept to fatigue analysis of welded joints
Autorzy:
Karolczuk, A.
Blacha, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/386732.pdf
Data publikacji:
2011
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
modelowanie
złącze
trwałość zmęczeniowa
modelling
joint
fatigue analysis
Opis:
W pracy przedstawiono oryginalny model wyznaczania rozkładu prawdopodobieństwa zniszczenia złączy spawanych wykorzystujący koncepcję najsłabszego ogniwa. Poprzez wprowadzenie charakterystyki zmęczeniowej materiału zastępczego uwzględniono niejednorodność strukturalną oraz naprężenia własne. Procedura identyfikacji właściwości mate- riału zastępczego wykorzystuje istniejące dane eksperymentalne uszeregowane w tzw. klasach FAT. Proponowany model uwzględnia również efekt skali poprzez jednoznaczne powiązanie parametru kształtu rozkładu z wielkością analizowanego elementu.
The present paper presents an original model for evaluation of failure probability of welded joints. The S-N curve for substitute (equivalent) material is being introduced in order to govern the issue of material inhomogeneity and post-weld stress. Extraction of characteristics for this material is based on existing experimental data, categorized into FAT classes. Among that, the proposed model takes into account also the vo- lume effect.
Źródło:
Acta Mechanica et Automatica; 2011, 5, 3; 51-54
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An alternative scheme for determination of joint reaction forces in human multibody models
Alternatywny sposób wyznaczania reakcji w stawach wieloczłonowych modeli ciała człowieka
Autorzy:
Blajer, W.
Czaplicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/279332.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
human body modeling
dynamic analysis
joint reaction forces
Opis:
Multibody models are commonly used in the analysis of human movements. The dynamic formulations often use minimal sets of generalized coordinates, and joint reactions (non-working reactions of model-intrinsic constraints) are excluded from evidence. A separate modeling effort is then required to determine joint reactions, and the arising numerical procedures are computationally arduous. In this paper, a novel efficient approach to the determination of joint reactions is developed, which naturally assists the minimal-form formulations of human body dynamics. The proposed scheme does not involve matrix inversion, and as such it is well suited for both symbolic manipulations and computer implementations. The method is illustrated with a seven-segment planar model of a human body. Some results from the inverse dynamics simulation of somersaults on a trampoline are reported.
Wieloczłonowe modele ciała człowieka są powszechnie wykorzystywane do analizy czynności motorycznych. Dla sformułowań dynamiki tych modeli stosowane są zwykle niezależne współrzędne uogólnione, co powoduje, że reakcje w połączeniach (idealne reakcje więzów wewnętrznych) są eliminowane na wstępnym etapie modelowania. Dla ich określenia wymagane są dodatkowe procedury modelowania matematycznego, a generowane tą drogą zależności charakteryzują się niską efektywnością numeryczną. W niniejszej pracy proponowane jest nieco inne podejście do wyznaczania reakcji w stawach, w sposób naturalny skojarzone z minimalno-wymiarowym formułowaniem dynamiki wieloczłonowych modeli ciała człowieka. Proponowane sformułowania nic wymagają odwracania macierzy, są tym samym efektywne zarówno dla wyprowadzeń symbolicznych, jak i zastosowań numerycznych. Metoda zilustrowana jest za pomocą siedmioczłonowego płaskiego modelu ciała człowieka. Prezentowane są wybrane wyniki obliczeń numerycznych odnoszące się do symulacji dynamicznej odwrotnej sportowca wykonującego salto na trampolinie.
Źródło:
Journal of Theoretical and Applied Mechanics; 2005, 43, 4; 813-824
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fatigue strength investigation of bonded joints
Autorzy:
Gieleta, R.
Derewońko, A.
Powiązania:
https://bibliotekanauki.pl/articles/243427.pdf
Data publikacji:
2007
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
adhesive bonded joint
fatigue strength
non-linear analysis
Opis:
Numerous advantages of the bonded joints result in wide application in the aircraft, motor industry or powertrain components. These types of joints enable joining materials with different mechanical properties (e.g. Stiffness) and dimensions without structure change. Proper joint design limits the field of local stress concentrations or even eliminates them. The structural integrity of complete structure depends on the fatigue estimation of the bonded joint. Application of the finite element method to life prediction of the double lap bonded joint metal-composite-metal is presented. Three dimensional numerical models are generated by professional engineering software tools. The contact problem is modelled between the epoxy resin and metal and composite surfaces. A laminated composite consists of the epoxy woven carbon prepreg. Elasto-plastic materials models of the adhesion and metal and orthotropy composite model allowed determining the contact normal stress in the interfaces in each deformation increment which is induced by an external load. MSC.Marc was used to determine the strain and stress distribution in the double lap bonded joint including contact normal stress in the steel/adhesive and laminated composite/adhesive interfaces. Two numerical models of the double lap bonded joint were compared. The use of the presented method is more suitable for structure optimisation than numerical analysis.
Źródło:
Journal of KONES; 2007, 14, 3; 177-186
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The intramontane Orava Basin - evidence of large-scale Miocene to Quaternary sinistral wrenching in the Alpine-Carpathian-Pannonian area
Autorzy:
Ludwiniak, Mirosław
Śmigielski, Michał
Kowalczyk, Sebastian
Łoziński, Maciej
Czarniecka, Urszula
Lewińska, Lena
Powiązania:
https://bibliotekanauki.pl/articles/138722.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Orava Basin
Central Carpathian Palaeogene Basin
structural analysis
strike-slip related basin
transrotational basin
joint pattern analysis
Western Carpathians
Kotlina Orawska
paleogeński basen centralno-karpacki
paleogeńskiego basen Karpat centralnych
analiza strukturalna
basen przesuwczy
basen transrotacyjny
Karpaty Zachodnie
Opis:
The Carpathian Orava Basin is a tectonic structure filled with Neogene and Quaternary deposits superimposed on the collision zone between the ALCAPA and European plates. Tectonic features of the south-eastern margin of the Orava Basin and the adjoining part of the fore-arc Central Carpathian Palaeogene Basin were studied. Field observations of mesoscopic structures, analyses of digital elevation models and geological maps, supplemented with electrical resistivity tomography surveys were performed. Particular attention was paid to joint network analysis. The NE-SW-trending Krowiarki and Hruštinka-Biela Orava sinistral fault zones were recognized as key tectonic features that influenced the Orava Basin development. They constitute the north-eastern part of a larger Mur-Mürz-Žilina fault system that separates the Western Carpathians from the Eastern Alps. The interaction of these sinistral fault zones with the older tectonic structures of the collision zone caused the initiation and further development of the Orava Basin as a strike-slip-related basin. The Krowiarki Fault Zone subdivides areas with a different deformation pattern within the sediments of the Central Carpathian Palaeogene Basin and was active at least from the time of cessation of its sedimentation in the early Miocene. Comparison of structural data with the recent tectonic stress field, earthquake focal mechanisms and GPS measurements allows us to conclude that the Krowiarki Fault Zone shows a stable general pattern of tectonic activity for more than the last 20 myr and is presently still active.
Źródło:
Acta Geologica Polonica; 2019, 69, 3; 339-386
0001-5709
Pojawia się w:
Acta Geologica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza geometryczna i ruchowa stawu kolanowego człowieka
Geometrical and mobility analysis of knee joint of man
Autorzy:
Stępniewski, A. A.
Powiązania:
https://bibliotekanauki.pl/articles/972139.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
analiza strukturalna
analiza kinematyczna
staw kolanowy
structural analysis
kinematical analysis
knee joint
Opis:
W pracy przeprowadzono analizę strukturalną i geometryczno-ruchową płaskiego modelu stawu kolanowego. Wyznaczono ruchliwość i zidentyfikowano więzy bierne. Określono podstawowe wymiary, konieczne do opisania geometrii stawu. Do analizy ruchowej przyjęto uproszczony model płaski. Wykorzystując przekształcenia układów współrzędnych Denavita-Hartenberga, wyznaczono wektory położeń charakterystycznych punktów kości udowej względem kości piszczelowej. Wyznaczono linię styku kości piszczelowej z udową dla pełnego zakresu ruchu w stawie. Opracowano algorytm wyznaczania współrzędnych położenia punktu przytwierdzenia więzadeł pobocznych do kości udowej dla zadanego położenia punktu przytwierdzenia względem kości piszczelowej. Zamieszczono przykład obliczeniowy będący ilustracją omówionego algorytmu.
The paper presents the structural, geometric and mobility analysis of flat mechanism of the knee joint model. The mobility was determined and passive bonds were identified. The basic dimensions, necessary for description of the joint geometry, were defined. The simplified flat model was assumed for the mobility analysis. Using the transformation of Denavit-Hartenberg systems of coordinates, vectors of position of the femoral bone characteristic points in relation to the tibial bone were determined. The shape of the tibial bone pan assuring solid contact of the bone during full range of movement in the joint was defined. There was worked out an algorithm for determining the position coordinates of the point of attaching marginal ligaments to the femoral bone for the given position of the attaching point in relation to the tibial bone. The example of computations illustrating the algorithm discussed is presented in the paper. It can be stated that in the joint flat model there appear three passive fetters: the point of the bone junction, two marginal ligaments along with the kinematic pair. The relative movement along circle of marginal ligaments ends is loaded with the radial error equal to 0,7 mm.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 6, 6; 342-345
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of the constraint effect on the mechanical properties and weldability of the mismatched weld joints. Part II
Autorzy:
Ranatowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/259003.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
weld joint
weldability
weldability analysis
thermal cycle
heat flow analysis
heat-affected zone
Opis:
Currently the welding as a technological process is concerned with special processes, the results of which cannot be checked in a complete degree by subsequent control, test of production what finally causes uncertainty of work of welded constructions. The process of welding is related to the local change of the internal energy of welded system and that leads to the local change of state of material expressing by change of microstructure and mechanical properties. This phenomena decide on the assessment of susceptibility of materials under defined welding condition and estimate of the weldability. It is compound relation and the mechanical behaviour of welded joints is sensitive to the close coupling between modules: heat transfer, microstructure evolution an mechanical fields. Welding process in physical meaning it is jointed with three laws govern mass and heat flow the laws of conservation of: mass, momentum and energy. The knowledge of the run of thermo-dynamical process under welding indicates on the possibility of active modelling and control of welding process with use intensive and extensive parameters. As the weld metal cools in the temperature range 2300 to 1800°K, the dissolved oxygen and deoxidising elements in liquid steel react to form complex oxide inclusions of 0.1 to 1 žm size range. In the temperature range 1800 to 1600°K, solidification of liquid to . ferrite starts und envelops these oxide inclusions. After . ferrite transforms to austenite in the temperature range 1100 to 500°K, the austenite transforms to different ferrite morphologies such as ferrite: allotriomorphic, Widmanstättena, and acicular. The macro-mechanical heterogeneity of welded structures is one of their primary features. The heterogeneous nature of the weld joints is characterised by macroscopic dissimilarity in mechanical properties. Numerical weldability analysis is a new powerful research and development tool which is useful for metallurgistics technologist and design engineers. Saying strictly the numerical analysis of weldability comprises thermodynamic, thermomechanical and microstructural modelling of the welding process. The result of this analysis is material susceptibility (SU). The fracture resistance of welded joints is mainly characterised by normalised parameters: SU1 = KIth / KIC for cold cracking or in the exploitation condition by SU2 = ./.C or J/JC, SU1 . SU2. From above-mentioned equations result that does not exist one global parameter which defines the step of susceptibility SU of base materials has been also executed with use of SINTAP program.
Źródło:
Polish Maritime Research; 2012, 2; 39-42
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza strukturalna, geometryczna i statyczna mechanizmu stawu kolanowego
Analysis of structural, geometrical and static of knee-joint mechanism
Autorzy:
Stępniewski, A.
Powiązania:
https://bibliotekanauki.pl/articles/386350.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
staw kolanowy
biomechanika
analiza strukturalna
knee joint
biomechanics
structural analysis
Opis:
W pracy przeprowadzono analizę strukturalną, geometryczną i statyczną mechanizmu wzorowanego na budowie stawu kolanowego człowieka. Wyznaczono ruchliwość, zidentyfikowano więzy bierne i sklasyfikowano mechanizm stawu. Określono podstawowe wymiary, konieczne do opisania geometrii stawu. Do analizy przyjęto uproszczony model płaski. Wykorzystując przekształcenia układów współrzędnych Denavita-Hartenberga, wyznaczono wektory położeń charakterystycznych punktów kości udowej i rzepki względem kości piszczelowej. Wyznaczono obciążenia elementów stawu. Zamieszczono przykład obliczeniowy będący ilustracją omówionego algorytmu obliczeniowego.
This article shows structural, geometrical and static analysis of the knee-joint. Mobility was determined and passive bonds were identified. The basic dimensions were defined, neces- sary for description of geometry of joint. Simplified flat model was accepted for mobility analysis. Using the transformation of arrangement co-ordinate Denavit-Hartenberg, vectors of sites characteristic of bones of femoral bone, according to tibial bone were defined. Loads of elements of the pond were set. Computational being example was put illustration of discussed algorithm.
Źródło:
Acta Mechanica et Automatica; 2010, 4, 1; 80-85
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Free vibrational analysis of rectangular ducts with different joint conditions
Autorzy:
Jade, N.
Venkatesham, B.
Powiązania:
https://bibliotekanauki.pl/articles/279956.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
rectangular duct
duct joint
experimental modal analysis
modal assurance criteria
Opis:
Rectangular ducts are fabricated using thin sheets of a metal with different joint conditions. Due to the presence of these joints, ducts deviate from their assumptive ideal shapes. The objective of the present work is to study the effect of different joint conditions and wall thickness on dynamic characteristics of the ducts. Experimental Modal Analysis (EMA) is performed on three rectangular ducts of different joint types. Numerical Modal Analysis (NMA) is also performed by considering that the ducts are of ideal rectangular shape (without joint condition). Correlation analysis is performed between EMA and NMA in terms of Modal Assurance Criteria (MAC), Relative Frequency Difference (RFD) plots and auto-MAC. It is observed that natural frequencies are in good agreement but there is a discrepancy in mode shapes.
Źródło:
Journal of Theoretical and Applied Mechanics; 2018, 56, 4; 1069-1081
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adaptive inventory control system for material items with continuous non-stationary demand
Autorzy:
Krajčovič, M.
Plinta, D.
Powiązania:
https://bibliotekanauki.pl/articles/406736.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
inventory control
algorithm
non-stationary demand
joint replenishment
inventory analysis
Opis:
This paper describes an algorithm of dynamic inventory control system for large numbers of material items with continuous non-stationary demand. It uses principles of pull inventory control systems, statistical inventory analysis and joint replenishment inventory systems. This algorithm was processed in software module (VBA for Excel) and applied in practice. The target of described algorithm is to keep an optimum inventory level and optimum customer service level in terms of inventory control of items with non-stationary demand.
Źródło:
Management and Production Engineering Review; 2014, 5, 1; 11-20
2080-8208
2082-1344
Pojawia się w:
Management and Production Engineering Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania termowizyjne obciążonego stawu biodrowego
Thermal research loaded hip joint
Autorzy:
Rusowicz, A.
Piwnik, J.
Powiązania:
https://bibliotekanauki.pl/articles/271286.pdf
Data publikacji:
2016
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
termowizja
staw biodrowy
analiza obrazu
thermography
hip joint
image analysis
Opis:
W artykule przedstawiono wyniki badań obciążonego stawu biodrowego. Staw biodrowy obciążano cyklami ćwiczeń gimnastycznych. Temperaturę w okolicach stawu monitorowano przy użyciu kamery termowizyjnej. Określono zmiany temperatury powierzchni skóry w wybranych miejscach.
The article presents the results of the load of the hip. The hip joint is loaded cycle exercise. The temperature in the vicinity of the joint were monitored using a thermal imaging camera. Changes of skin surface temperature at selected locations are analyzed.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2016, 21, 1; 49-53
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Resistance of the Welds in CHS Joints with the Rib Plates
Autorzy:
Milewski, P.
Broniewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/104796.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
trusses
hollow section
K joint with ribs
welds
FEM analysis
Opis:
With regard to the calculation of welds’ resistance in connections between hollow sections in EN 1993-1-8, very general information is given without any indication of specific calculation procedures. These recommendations are basically as follows: the resistance of the welds must have the value of the cross-section and assessment of the welds’ resistance based on the effective lengths is allowed in cases when forces in the braces are smaller than the resistance of the joint, but the detailed method is not specified. The objective of this paper is to present the most up-to-date information for the design of welds for overlap joints with reinforcing rib plates. The article presents the FEM analysis of the welds in the intermediate joint with the rib in a truss made of circular hollow sections. The conclusions from the analysis were presented.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 167-176
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of functional methods for human movement modelling
Autorzy:
Gastaldi, L.
Lisco, G.
Pastarelli, S.
Powiązania:
https://bibliotekanauki.pl/articles/307058.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
analiza funkcjonalna
analiza ruchu
modelowanie
kinematyka
functional analysis
motion analysis
human modelling
joint kinematics
Opis:
Purpose: accurate assessment of human joint parameters is a critical issue for the quantitative movement analysis, due to a direct influence on motion patterns. In this study three different known functional methods are experimentally compared to identify knee joint kinematics for further gait and motion analysis purposes. Methods: taking into account the human knee physiology complexity, within its roto-translation, the study is conducted on a lower limb mechanical analogue with a polycentric hinge-based kinematic model. The device mimics a joint with a mobile axis of rotation whose position is definable. Sets of reflective markers are placed on the dummy and flexion-extension movements are imposed to the shank segment. Marker positions are acquired using an optoelectronic motion capture system (Vicon 512). Results: acquired markers’ positions are used as input data to the three functional methods considered. These ones approximate the polycentric knee joint with a fixed single axis model. Different ranges of motion and number of markers are considered for each functional method. Results are presented through the evaluation of accuracy and precision concerning both misalignment and distance errors between the estimated axis of rotation and the instantaneous polycentric one, used as reference. Conclusion: the study shows the feasibility of the identification of joint parameters with functional approaches applied on a polycentric mechanism, differently from those usually conceived by the reviewed algorithms. Moreover, it quantifies and compares the approximation errors using different algorithms, by varying number and position of markers, as well ranges of motion.
Źródło:
Acta of Bioengineering and Biomechanics; 2015, 17, 4; 31-38
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of statistical analysis and functional assessment tests in patients after trochanteric fractures treated surgically in an individual rehabilitation programme
Autorzy:
Skowronek, Robert
Zawora, Józef
Kwiatkowski, Krzysztof
Skalski, Konstanty
Powiązania:
https://bibliotekanauki.pl/articles/2114116.pdf
Data publikacji:
2021
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
hip joint
rehabilitation
variance analysis
correlations of variables
variation measures
Opis:
Physiotherapeutic procedures after surgical treatment of trochanteric fractures of femurs are a very important element of a post-operative management because they have a significant influence on the final result of physiotherapy. This is due to the nature of the frac-ture and the frequency of its occurrence. The aim of the work is, in particular, to determine the relationship between functional assessment scales in patients after trochanteric fractures treated surgically using extended statistical analysis including regression equations. Statistical analysis included a group of patients, which participated in a specialized programme of a post-operative procedure, called the ‘Individual’ Group. The matrix of research results, calculations of basic statistical measures, such as position, variability, interdependence, asymmetry and concentration were presented for this group. Regression equations representing the relationships between the considered variables, in particular concerning the applied scales and post-operative tests, were presented. Their purpose, mathematical interpretation, results of calculations and statistical tests were discussed. Attention was paid to the high correlation between the Parker and Mobility tests. The extended statistical analysis makes it possible to create an own system for assessing the treatment results of patients after trochanter-ic fractures are treated surgically.
Źródło:
Acta Mechanica et Automatica; 2021, 15, 3; 132--142
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The role of strategic analysis in shaping the conditions for, and the range of, cooperation between business entities
Rola analizy strategicznej w kształtowaniu uwarunkowań i zakresu współpracy podmiotów gospodarczych
Autorzy:
Dwojak, A.
Powiązania:
https://bibliotekanauki.pl/articles/2051358.pdf
Data publikacji:
2020
Wydawca:
Akademia Bialska Nauk Stosowanych im. Jana Pawła II w Białej Podlaskiej
Tematy:
systems analysis
strategic analysis
cooperation
acquisitions
mergers
divestiture
alliances
technology transfer
licensing
franchise
joint venture
Opis:
Subject and purpose of work: The subject matter of this paper includes selected examples of tools applied in systems analysis and strategic analysis in relation to the influence of their results on the forms of cooperation between business entities. The study is aimed at provoking a deeper thought on the outcomes of the lack of a system-based approach on the effects of cooperation, and consequently at reducing the negative experience arising from the lack of understanding of the conditions affecting the expected results. Materials and methods: This publication is an overview of the issue based on the interpretation and synthesis of the available literature on the subject. Results: The author suggests that the specific conditions, starting from the impact of the broad geopolitical surroundings, the current government policy, legal regulations, culture circles, market development stage or a partner’s place in the production chain, through customs, procedures, processes, intra-organisational standards, affect not only the culture of the organisation itself, but also its reputation and financial result. Conclusions: The influence of the new “virtual” sphere of economic contacts, as a vital element of strategic analysis, was stressed.
Przedmiot i cel pracy: Przedmiotem opracowania są wybrane przykłady narzędzi analizy systemowej i strategicznej, w odniesieniu do wpływu ich rezultatów na formy współdziałania pomiędzy podmiotami gospodarczymi. Opracowanie ma na celu skłonienie do refleksji nad skutkami braku podejścia systemowego na oczekiwane efekty kooperacji, a przez to na zmniejszenie negatywnych doświadczeń wynikających z braku zrozumienia uwarunkowań wpływających na oczekiwane efekty. Materiały i metody: Publikacja ma charakter przeglądowy i oparta jest na interpretacji i syntezie dostępnej literatury przedmiotu. Wyniki: Autor sugeruje, że określone uwarunkowania począwszy od wpływu szerokiego otoczenia geopolitycznego, aktualnej polityki rządu, regulacji prawnych, kręgu kulturowego, etapu rozwoju rynku czy miejsca jakie partner zajmuje w łańcuchu produkcji, poprzez zwyczaje, procedury, procesy, normy wewnątrz organizacji, wpływają nie tylko na kulturę samej organizacji, ale także na jej opinię i wynik finansowy. Wnioski: Podkreślony został wpływ nowej „wirtualnej” strefy kontaktów gospodarczych jako kluczowego elementu analizy strategicznej.
Źródło:
Economic and Regional Studies; 2020, 13, 2; 250-263
2083-3725
2451-182X
Pojawia się w:
Economic and Regional Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wytrzymałościowa endoprotezy stawu kolanowego
Strength analysis of total knee prosthesis
Autorzy:
Tejszerska, D
Długoszewski, T.
Gąsiorek, D
Powiązania:
https://bibliotekanauki.pl/articles/99077.pdf
Data publikacji:
2010
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
analiza wytrzymałościowa
endoproteza
staw kolanowy
ANSYS
strength analysis
endoprosthesis
knee joint
Opis:
W artykule przedstawiono analizę wytrzymałościową endoprotezy stawu kolanowego z wyłączeniem elementu udowego dla kilku wariantów obciążenia. Analiza ta pozwala na obserwację wpływu obciążenia na stan naprężeń i odkształceń w kości i endoprotezie. Model i jego analizę przeprowadzono metodą elementów skończonych w programie Ansys Workbench.
Numerical strength analysis of total knee prosthesis without femur element for few variants of load was presented in this paper. This analysis allow us observe the influence of load on the state of stress and strain in tibia bone and prosthesis . The model and its finite element analysis was performed in ANSYS Workbench.
Źródło:
Aktualne Problemy Biomechaniki; 2010, 4; 213-218
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Investigation of Ergonomics Analysis Tools Used in Industry in the Identification of Work-Related Musculoskeletal Disorders
Autorzy:
Pascual, S. A.
Naqvi, S.
Powiązania:
https://bibliotekanauki.pl/articles/90644.pdf
Data publikacji:
2008
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
ergonomics analysis tools
surveys, certified ergonomists
joint health and safety committees
Opis:
Web-based surveys were sent to Canadian certified ergonomists, Joint Health and Safety Committees (JHSCs) and health and safety certification trainers to understand better which ergonomics analysis tools were used in industry and help JHSCs obtain the necessary training required to reduce work-related musculoskeletal disorders (WMSDs). The results showed that most of the certified ergonomists used the Snook/Mital tables, the National Institute of Occupational Safety and Health (NIOSH) equation and rapid upper limb assessment (RULA)/rapid entire body assessment (REBA). The most frequently used methods by JHSCs to identify ergonomics risk were injury reports and worker complaints. The surveys for the health and safety certification trainers revealed that most curricula did not include ergonomics analysis tools. There appears to be a gap between what is recommended by certified ergonomists for JHSC, what is taught in training and what is used by JHSCs for ergonomics risk analysis. A better understanding, modifications in training curricula and education of JHSCs are needed to help reduce WMSDs.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2008, 14, 2; 237-245
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physical and reliability aspects of high-pressure ammonia water pipeline failures
Autorzy:
Michnej, Maciej
Młynarski, Stanisław
Pilch, Robert
Sikora, Wojciech
Smolnik, Maksymilian
Drożyner, Przemysław
Powiązania:
https://bibliotekanauki.pl/articles/2200924.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
coke oven battery
pipeline
welded joint
crack
structural analysis
reliability assessment
Opis:
The paper concerns the problem of the occurrence of failures of the high-pressure ammonia water pipeline of the coke oven battery complex, which is affected by chemical and thermal factors as well as the operating pressure occurring during its use. Pipeline failures manifested themselves as leaks (leakage of the medium) due to cracks in the area of the pipeline thermal elongation compensators. The conducted tests included, among others: visual inspection, penetration tests, macroscopic and microscopic tests as well as chemical analysis of the material. The study includes microscopic photographs of the material structure and cracks. The results of the pipeline strength and reliability analysis were also presented. On the basis of the conducted research and analyses conclusions were formulated. The assumed cause of the damage was the incorrectly made welded joints. Formulated recommendations and proposals for actions aimed at avoiding further failures of this and similar pipelines were related to the inspection time and preventive renewal.
Źródło:
Eksploatacja i Niezawodność; 2022, 24, 4; 728--737
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena poziomu emisji wolnozmiennego pola magnetycznego
Assessment of the low-frequency magnetic magnetic-field emissions
Autorzy:
Pałczyńska, B.
Powiązania:
https://bibliotekanauki.pl/articles/266742.pdf
Data publikacji:
2014
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
małoczęstotliwościowe pole magnetyczne
adaptacyjna analiza czasowo-częstotliwościowa
algorytm pogoni za dopasowaniem
wskaźnik ekspozycji na pole magnetyczne
low-frequency magnetic field emission
adaptive joint time-frequency analysis
matching pursuit algorithm
Opis:
W artykule przedstawiono sposób oceny poziomu ekspozycji na wolnozmienne pola magnetyczne w odniesieniu do dopuszczalnych wartości, zawartych w zaleceniach międzynarodowych International Commission on Non-Jonizing Radiation Protection (ICNIRP). Estymację wskaźnika ekspozycji przeprowadzono na podstawie adaptacyjnej analizy czasowo– częstotliwościowej, zarejestrowanych przebiegów czasowych indukcji pola magnetycznego. Analizę adaptacyjną, opartą na algorytmie pogoni za dopasowaniem (ang. matching pursuit MP) zaimplementowano w graficznym zintegrowanym środowisku programowania LabVIEW. Przedstawiono wyniki analiz sygnału pomiarowego, reprezentującego poziom indukcji wolnozmiennego pola magnetycznego, zarejestrowanego w otoczeniu okrętowych odbiorników dużej mocy.
The occurrence of low-frequency, distorting magnetic fields in ship’s environment, directly affects the reliability of the electrical and electronic equipment and systems, and this way, the safety of navigation. These effects are also significant for the health of people staying near to the sources of magnetic field. Due to the above-mentioned reasons, emission limits have been defined by international committees both for the functional aspects and for limiting human exposure to magnetic emissions. For exposure to low-frequency magnetic fields, the magnetic flux density B is the parameter used by International Commission on Non-Ionizing Radiation Protection (the ICNIRP) for the definition of the reference levels. For the special case of simultaneous exposure to multiple frequency fields, a summation formula defined in ICNIRP guidelines was applied. In the paper, the way of the estimation of the exposure level to a low-frequency magnetic field in reference to admissible levels, proposed by ICNIRP. The instantaneous values of the safety factor were estimated with the adaptive joint timefrequency analysis of the digitized magnetic-flux density waveforms, acquired by measurement. The adaptive transform, based on the matching pursuit algorithm, was implemented in the LabVIEW software. The selected results of the analysis of the recorded signals of the safety factor of magnetic flux density in the surroundings of the ship’s motor drive with the power frequency converters are presented.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2014, 38; 49-52
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of the constraint effect on the mechanical properties and weldability of the mismatched weld joints. Part I
Autorzy:
Ranatowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/258976.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
weld joint
weldability
weldability analysis
thermal cycle
heat source model
heat flow analysis
heat-affected zone
Opis:
The process of welding has dynamic character and is related with the local change of the internal energy E of welded system and can be defined by general dependence between intensive .j and extensive .j parameters. The knowledge of the run of thermo-dynamical process under welding indicates on the possibility of active modelling of weldability and the control of welding process: .j = .E/..j. Hence, these process can be enhanced by mathematical modelling and numerical analysis of weldability models of, i.e. welding processes of material behaviour in welding and the strength of welded structures. The main attention is focused on the assessment of susceptibility of materials under defined welding conditions using fracture mechanics parameters. The analysis is based on the normalised parameters such as: ./.c, KIth/KIC, as a measure of the susceptibility of materials in welding process. The deformation process and fracture parameters calibrations are influenced by constraint; hence the importance of determining the deformation behaviour and fracture parameters as a function of constraint. Furthermore, there established analytically the condition of welding process in mismatched weld joints for strength equal to base metal. Finally, same analytical examples which present new capabilities of weldability estimates and mechanical properties of mismatched weld joints are presented.
Źródło:
Polish Maritime Research; 2012, 1; 44-51
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical study of the prestressed connectors and their distribution on the strength of a single Lap, a double lap and hybrid joints subjected to uniaxial tensile test
Badania numeryczne docisku w łącznikach oraz ich rozmieszczenia na wytrzymałość połączeń zakładkowych, dwunakładkowych i hybrydowych poddanych jednoosiowemu rozciąganiu
Autorzy:
Sadowski, T.
Golewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/354882.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
prestressed connectors
numerical analysis
single lap joint
hybrid joint
połączenie sprężone
analiza numeryczna
złącze zakładkowe
złącze dwunakładkowe
złącze hybrydowe
Opis:
Prestressed joints are widely used in construction using connectors in the form of screws, whose task is to strong clamping of joined parts, thereby the internal forces in joint are transferred by surface friction contact of the elements. In the automotive and aerospace industries hybrid joints are more widely applied. Mechanical connectors are added to the adhesive joint in form of rivets, screws or clinch increasing its strength properties. The aim of this study was to determine how the prestressed connectors influence the mechanical response of hybrid, single and double lap joints. The influence of different distribution of the connectors was also investigated. Numerical study was conducted in ABAQUS program. Mechanical connectors were modeled by using fasteners, that allowed for a considerable simplification of the numerical model. In their application, there is no need for an additional submodels for connectors in the form of the rivet or the bolt. Prestressing is activated by direct application of the force to the connector. In the numerical examples the authors assumed that the diameter of the mechanical connectors was equal to 6mm and shear strength was equal 1kN. Adhesive layers were modeled by using cohesive elements for which maximum shear stresses and fracture energy were specified. The layer thickness was assumed to be equal 0.1mm and it was initially removed from the areas where mechanical connectors were placed. Two types of joints were analysed in the study: the single lap joint with lap dimensions 40x40mm as well as the double lap joint with lap dimensions 40x20mm, from which it results that theoretical strength of both connections should be the same. The prestressing of connectors was introduced by the force 1.5kN. For all pure - mechanical joints and for single lap joints positive effects were obtained. For double lap joints additional prestressing did not significantly affect for their strength. The influence of distribution of mechanical connectors was additionally analyzed by consideration of three configurations, where the rows of rivets were located at distances of 5, 10 and 15mm from the lap edge. The maximum increase of the load capacity by 24% was achieved for single lap joint as well as 35.7% for double lap joint. The obtained numerical results indicate the positive effects of additional pressure and allows for practical suggestions how to correct and optimize spacing distance of mechanical connectors in hybrid joints to get better mechanical response.
Połączenia sprężone są szeroko stosowane w budownictwie przy wykorzystaniu łączników w postaci śrub, których zadaniem jest silne docisnięcie do siebie łączonych elementów, wskutek czego siły w złączu są przenoszone dzięki tarciu stykających się powierzchni tych elementów. W przemyśle samochodowym i lotniczym coraz powszechniej stosuje się połączenia hybrydowe. Do złącza klejowego wprowadzane są łączniki w postaci nitów, śrub lub przetłoczeń podnosząc jego cechy wytrzymałościowe. Celem przeprowadzonych badań było określenie jak wpływa sprężenie łączników w połączeniach hybrydowych w złączach zakładkowych oraz dwunakładkowych także przy różnym rozmieszczeniu łączników. Badania numeryczne były przeprowadzone w programie Abaqus. Połączenia mechaniczne były modelowane przy użyciu tzw. fastenerów, które pozwalają na znaczne uproszczenie budowy modelu. Przy ich zastosowaniu nie ma potrzeby wykonywania dodatkowego modelu w postaci łącznika - nitu lub śruby. Sprężenie jest natomiast wywoływane poprzez bezpośrednie podanie wartości siły wystepującej w łączniku. Dla łączników mechanicznych została podana siła powodująca ściecie o wartości 1kN a ich średnica wynosiła 6mm. Warstewka kleju była modelowana przy użyciu elementów kohezyjnych dla których zostały określone maksymalne naprężenia styczne oraz energia zniszczenia. Grubość warstewki wynosiła 0,1mm i wstępnie została ona usunięta z obszarów w których występowały łączniki mechaniczne. Badaniom poddano dwa typy połączeń: zakładkowe o wymiarach zakładki 40x40mm oraz dwunakładowe o wymiarach zakładek 40x20mm z czego wynika fakt, że teoretycznie wytrzymałość na ścinanie obu połączeń powinna być jednakowa. Analizowano połączenia sprężone siłą 1,5kN uzyskując pozytywne efekty dla wszystkich połączeń czysto - mechanicznych oraz dla połączeń zakładkowych. Dla połączeń dwunakładkowych sprężanie nie wpływa znacząco na ich wytrzymałość. Dodatkowo w pracy analizowano wpływ rozmieszczenia łączników mechanicznych rozważając trzy konfiguracje, gdzie rzędy nitów znajdowały się w odległościach 5, 10 i 15mm od granicy zakładki. Uzyskano tym samym maksymalny wzrost nośności o 24% dla połączeń zakładkowych oraz o 35,7% dla dwunakładkowych. Wykonane prace świadczą o pozytywnych skutkach sprężania połączeń a także dają wskazówki do prawidłowego - bardziej optymalnego wytrzymałościowo rozmieszczania łączników mechanicznych w połączeniach hybrydowych.
Źródło:
Archives of Metallurgy and Materials; 2013, 58, 2; 579-585
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the plate location used in clavicle fractures during shoulder abduction and flexion movements: a finite element analysis
Autorzy:
Calisal, E.
Ugur, L.
Powiązania:
https://bibliotekanauki.pl/articles/306467.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
obojczyk
złamanie
FEM
acromioclavicular joint
clavicle fractures
plate position
finite element analysis
Opis:
Plate fixation is a commonly used surgical method in clavicular fracture treatment. The main purpose of this treatment is making the painless shoulder girdle and bring the functions to the optimum level. Plate fixation position still remains controversial. We aimed to investigate the effect of the plate position in clavicle midshaft fractures during shoulder movements. Methods: A normal anatomical shoulder joint was modeled using computed tomography images. A fracture line was created on the clavicle. Plate was placed superior to the clavicle in group 1 and anterior in group 2. The impacts of joints, plates, screws, ligaments and clavicle have been shown during 150° flexion and abduction movements of the shoulder by finite element analysis. Analyzes were made non-linear using ANSYS (version 18) and the same boundary conditions were applied in all models. Results: The load values in the plate, screws, ligaments, and clavicle were higher in group 1 than group 2 during abduction and flexion movements. Especially the load on the ac ligament was excessive. Load value in the glenohumeral joint was found similar both groups. The load values in the flexion movement were higher than the abduction movement in both groups. Conclusions: Anterior clavicle plating provides less stress on material and shoulder girdle, compared to superior plating, during shoulder abduction and flexion movements.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 4; 41-46
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wstępna analiza stawu biodrowego człowieka fizjologicznie prawidłowego oraz po zabiegu kapoplastyki
Preanalysis of human hip joint physiologically correct and after operation of resurfacing
Autorzy:
John, A.
Kokot, G.
Duda, M.
Powiązania:
https://bibliotekanauki.pl/articles/99081.pdf
Data publikacji:
2010
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
staw biodrowy
kapoplastyka
obciążenie
analiza numeryczna
hip joint
resurfacing
load
numerical analysis
Opis:
W pracy przedstawiono sposób zamodelowania stawu biodrowego człowieka odpowiadający stanowi przed operacją kapoplastyki (fizjologicznie prawidłowemu) oraz stanowi po operacji. W obu modelach założono takie same warunki brzegowe. Następnie przeprowadzono analizę numeryczną oraz porównano wyniki w celu określenia, które miejsca modeli są najbardziej narażone na przeciążenia podczas fizjologicznego obciążenia stawu biodrowego.
In this work two states of human hip joint were modelled refers to: state physiologically correct and after resurfacing operation. These same boundary conditions were assigned to both models and the FEM analysis was conducted. The obtained results were compared and finally the most dangerous and overloading areas were defined for physiological loading of hip joint.
Źródło:
Aktualne Problemy Biomechaniki; 2010, 4; 79-84
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Displacement analysis of the human knee joint based on the spatial kinematic model by using vector method
Autorzy:
Knapczyk, J.
Góra-Maniowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/386514.pdf
Data publikacji:
2017
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
human knee joint model
kinematic analysis
parallel mechanism
constraint equations
vector method
Opis:
Kinematic model of the human knee joint, considered as one-degree-of-freedom spatial parallel mechanism, is used to analyse the spatial displacement of the femur with respect to the tibia. The articular surfaces of femoral and tibia condyles are modelled, based on selected references, as spherical and planar surfaces. The condyles are contacted in two points and are guided by three ligaments modelled as binary links with constant lengths. In particular, the mechanism position problem is solved by using the vector method. The obtained kinematic characteristics are adequate to the experimental results presented in the literature. Additionally, the screw displacements of relative motion in the knee joint model are determined.
Źródło:
Acta Mechanica et Automatica; 2017, 11, 4; 322-327
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluating measurement accuracy and repeatability with a new device that records spatial knee movement
Autorzy:
Tian, Fei
Huang, Qiuyue
Zheng, Zhi
Li, Ningwei
Zhu, Ting
Dai, Wei
Wang, Shaobai
Powiązania:
https://bibliotekanauki.pl/articles/27324129.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
gait analysis
repeatability
motion analysis
three-dimensional
knee joint
analiza chodu
powtarzalność
analiza ruchu
trójwymiarowy
staw kolanowy
Opis:
Purpose: A novel portable system has been used to evaluate spatial knee movement, but its accuracy and repeatability is not known. The aim of this study was to investigate the accuracy and repeatability of the measurement. Methods: Ten healthy participants were included, and the knee motion trajectory during walking were assessed. Six evaluations were conducted (three days by two raters) for each participant. The motion parameters at the key points and the range of motion were statistically analyzed. Intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and the Bland–Altman method were used. Results: For intra-rater repeatability, 1) the ICC values range from 0.75 to 0.9 for rotations; and 0.64 to 0.96 for translations. Among the ICC values, 100% of rotations and 90% of translations were not less than 0.70; 2) among the SEM values, 100% of rotations were not more than 5°, while 73.3% of translations were less than 3 mm. For inter-rater repeatability, 1) the ICC values range from 0.68 to 0.99 for rotations; and 0.57 to 0.93 for translations. Among the ICC values, 95.6% of rotations and 82.2% of translations were not less than 0.70; 2) among the SEM values, 100% of rotations were not more than 5°, and 48.9% of translations were less than 3 mm. The Bland–Altman plots showed good agreement for intra- and inter-repeatability. Conclusions: The results indicated that the accuracy and repeatability of the measurement were acceptable, except for the inter-rater repeatability for translation. This may help researchers and physicians better interpret the measurement data.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 3; 55--67
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Historyczne złącza ciesielskie
Historical carpentry joints
Autorzy:
Jasieńko, J.
Nowak, T.
Karolak, A.
Powiązania:
https://bibliotekanauki.pl/articles/218278.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Konserwatorów Zabytków
Tematy:
konstrukcja drewniana
połączenie ciesielskie
znak ciesielski
połączenie czopowe
połączenie wrębowe
połączenie stykowe
analiza pracy statycznej połączeń
wzmocnienie połączeń
timber structure
carpentry joint
carpenter’s mark
mortise and tenon joint
notched joint
scarf joint
analysis of static behavior of joint
reinforcement of joint
Opis:
Praca stanowi wstępne zebranie stanu aktualnej wiedzy dotyczącej historycznych złączy ciesielskich i będzie kontynuowana przez cykl publikacji w „Wiadomościach Konserwatorskich” na temat szczegółowych analiz pracy statycznej poszczególnych typów złączy. W pracy przedstawiono rozwój połączeń ciesielskich na przestrzeni wieków oraz typologię połączeń występujących w ścianach i więźbach dachowych. Skupiono się głównie na pracy statycznej wybranych połączeń ciesielskich, przedstawiono przykłady typowych połączeń w historycznych więźbach dachowych, dokonując ich opisu i analizy. Opisano dotychczasowe badania połączeń, w tym badania metodą elastooptyczną. Następnie przedstawiono metody wzmacniania i naprawy połączeń oraz przykłady dokonanych interwencji konserwatorskich. Wyniki przeprowadzonej analizy literatury przedmiotu zaprezentowano w niniejszej pracy.
The paper represents an initial effort to review our current knowledge concerning carpentry joints and will be continued as a series of papers in the “Journal of Heritage Conservation” focused on detailed analysis of static behaviour of specific types of joints. The paper discusses the development of carpentry joints over the centuries and presents a typology of joints found in timber walls and roof structures. The focus is mainly on the static behaviour of selected car- pentry joints with presentation of examples of typical joints found in historic timber roof structures, which are described and analysed. Existing research on testing joints is reviewed, including photo-elasticity testing. Methods for reinforcement and repair of joints are presented, along with examples of heritage conserva- tion interventions. The results of a literature review are presented in the paper.
Źródło:
Wiadomości Konserwatorskie; 2014, 40; 58-82
0860-2395
2544-8870
Pojawia się w:
Wiadomości Konserwatorskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Anatomical protocol for gait analysis: joint kinematics measurement and its repeatability
Autorzy:
Żuk, M.
Trzeciak, M.
Powiązania:
https://bibliotekanauki.pl/articles/281538.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
joint kinematics
gait analysis protocol
repeatability
anatomical protocol
marker-set
motion capture system
Opis:
International Society of Biomechanics has proposed a general reporting standard for joint kinematics based on anatomical reference frames. Nevertheless, the gait analysis protocols based on this standard are still poorly reported. The purpose of the current study is to propose and preliminarily assess the potential of an anatomically based ISB 6-DOF protocol, which combines the ISB reporting standard together with a marker cluster technique. The proposed technical marker set enables full description of the lower limb kinematics (including three-dimensional ankle-foot complex rotations) according to the current biomechanical recommendation. The marker set provides a clinically acceptable inter-trial repeatability and minimal equipment requirements.
Źródło:
Journal of Theoretical and Applied Mechanics; 2017, 55, 1; 369-376
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An artificial neural network approach and sensitivity analysis in predicting skeletal muscle forces
Autorzy:
Vilimek, M.
Powiązania:
https://bibliotekanauki.pl/articles/306321.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
staw łokciowy
mięśnie
sieć neuronowa
elbow joint
muscle force prediction
neural network
sensitivity analysis
Opis:
This paper presents the use of an artificial neural network (NN) approach for predicting the muscle forces around the elbow joint. The main goal was to create an artificial NN which could predict the musculotendon forces for any general muscle without significant errors. The input parameters for the network were morphological and anatomical musculotendon parameters, plus an activation level experimentally measured during a flexion/extension movement in the elbow. The muscle forces calculated by the ‘Virtual Muscle System’ provide the output. The cross-correlation coefficient expressing the ability of an artificial NN to predict the “true” force was in the range 0.97 - 0.98. A sensitivity analysis was used to eliminate the less sensitive inputs, and the final number of inputs for a sufficient prediction was nine. A variant of an artificial NN for a single specific muscle was also studied. The artificial NN for one specific muscle gives better results than a network for general muscles. This method is a good alternative to other approaches to calculating of muscle force.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 3; 119-127
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza stanu biomechanicznego w stawie biodrowym po całkowitej alloplastyce z różnymi wariantami endoprotez bezcementowych
The analysis of biomechanical state in a hip joint after complete alloplastics with different variant of cementless endoprosthesis
Autorzy:
Ryniewicz, A.M.
Madej, T.
Powiązania:
https://bibliotekanauki.pl/articles/189404.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
staw biodrowy
endoprotezy bezcementowe
analiza
naprężenia
przemieszczenia
hip joint
cementless endoprosthesis
analysis
stresses
translations
Opis:
W opracowaniu wykonano modelowanie i symulacje rozkładów naprężeń i przemieszczeń w aplikacjach z bezcementowymi endoprotezami stawu biodrowego. Analizie poddano biołożyska z panewkami o strukturze warstwowej wykonane z polietylenu wysokocząsteczkowego oraz korundu i polietylenu wysokocząsteczkowego, z zewnętrznymi obejmami z tytanu. We wszystkich endoprotezach głowy były korundowe, a trzpienie tytanowe. Endoprotezy osadzano wirtualnie, w odwzorowanych na podstawie tomografii komputerowej strukturach kostnych. Dla zamodelowanych geometrycznie obiektów badań dokonano analizy wytrzymałościowej z wykorzystaniem metody elementów skończonych. Wyniki badań pozwoliły porównać rozwiązania konstrukcyjne endoprotez oraz ocenić charakter oddziaływania sztucznego stawu na otaczające tkanki kostne w warunkach indywidualnego pacjenta.
Modelling and simulation of the stress distribution and displacements in the applications with cementless endoprosthesis of a hip joint were carried out. The analysis subjected biobearings with cups of layered structures made from high molecular polyethylene, corundum, and high molecular polyethylene with external connection clips from titanium. The heads in all endoprosthesis were from corundum and the stems from titanium. The endoprosthesis were seated virtually in natural bone struc- tures that had been obtained from computer tomography. The stress analysis for the geometrically modelled objects of research was made using the finite element method. The results of the analysis allowed us to estimate the stress and displacements distribution in endoprosthesis and the character of the interaction of the artificial joint on the surrounding bone tissue in the conditions of an individual patient.
Źródło:
Tribologia; 2010, 2; 137-152
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the biomechanical behaviour of articular cartilage in hindfoot joints
Autorzy:
Venturanto, C.
Pavan, P. G.
Forestiero, A.
Carniel, E. L.
Natali, A. N.
Powiązania:
https://bibliotekanauki.pl/articles/307388.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ankle joint
articular cartilage
constitutive model
numerical analysis
staw skokowy
chrząstka stawowa
analiza numeryczna
Opis:
Numerical models represent a powerful tool for investigating the biomechanical behavior of articular cartilages, in particular in the case of complex conformation of anatomical site. In the literature, there are complex non-linear-multiphase models for investigating the mechanical response of articular cartilages, but seldom implemented for the analysis of high organized structure such as the foot. In the present work, the biomechanical behavior of foot cartilage is investigated by means of a fiber-reinforced hyperelastic constitutive model. The constitutive parameters are obtained through the comparison between in vitro experimental indentation tests on cartilage and numerical analysis data interpreting the specific experimental conditions. A finite element model of the hindfoot region is developed. Particular attention is paid to model cartilage in order to respect its morphometric configuration, including also the synovial capsule. The reliability of the procedure adopted is evaluated by comparing the numerical response of tibio-talar joint model with in vivo experimental tests mimicking the foot response in stance configuration.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 2; 57-65
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Moment resistance of I-section end-plate roof girder splices; a case study
Nośność na zginanie połączenia doczołowego elementów dwuteotywch dźwigara dachu, studium przypadku
Autorzy:
Żółtowski, K.
Kalitowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/231254.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
połączenie doczołowe
połączenie niesprężone
połączenie zginane
analiza MES
dach
hala sportowa
end-plate joint
non-preloaded joint
bending connection
FEM analysis
roof
sports hall
Opis:
This article deals with the problem of determining the resistance of end-plate connections. A nonlinear FEM model of the joint was constructed in order to predict its carrying capacity. A standard code procedure was done as well. The analyses have been done to assess atypical end-plate joints designed and constructed as a part of roof structures.
Wyznaczenie nośności styków doczołowych powinno być przeprowadzone z należytą dbałością, ze względu na wysoki stopień skomplikowania i odpowiedzialność tego elementu konstrukcyjnego. W przypadku szacowania nośności zginanych połączeń doczołowych zgodnie z normą PN-90/B-03200 należy przede wszystkim zwrócić uwagę na warunek minimalnej grubości blachy czołowej, użycie śrub o odpowiedniej, ujętej w procedurze wytrzymałości oraz stosowanie rozkładów śrub w węźle, które zostały przebadane i uznane za właściwe. Metoda składnikowa zaproponowana w PN-EN 1993-1-8 pozwala uwzględnić trzy różne modele zniszczenia styku i wykorzystuje bardziej złożone modele matematyczne, lecz uzyskany rezultat wciąż należy traktować jako przybliżony. Dodatkowo, w przypadku obu normatywów, dla połączeń elementów o smukłych środnikach (jak to miało miejsce w opracowanym studium przypadku (rys. 1), należy dokonać sprawdzenia, które ze śrub w sposób decydujący biorą udział przy przenoszeniu momentu zginającego. Procedury ujęte w obu normach nie rozwiązują wprost tego problemu.
Źródło:
Archives of Civil Engineering; 2016, 62, 4/I; 187-200
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sprężystość elementów meblowych sklejanych warstwowo
Uprugost' skleivaemykh poslojjno mebel'nykh elementov
Elasticity of furniture elements glue by layers
Autorzy:
Dziegielewski, S.
Wilczynski, A.
Powiązania:
https://bibliotekanauki.pl/articles/805746.pdf
Data publikacji:
1990
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
sprezystosc
elementy meblowe
klejenie warstwowe
badania
analiza
spoiny klejowe
elasticity
furniture element
analysis
glue joint
Opis:
Соответствующие исследования охватывали послойно склеиваемую буковую древесину предназначенную на выбранные конструкционные мебельные элементы. Целью исследований было определение упругостных свойств этих элементов совместно с определением зависимости между модулями упругости послойно склеиваемых элементов с различным числом слоев, их толщины и направления сгиба. Для достижения указанной цели проводились теоретические исследования с последующей проверкой на основании результатов экспериментальных изысканий. Проведенные анализы показали, что модуль упругости элементов из буковой древесины склеиваемой послойно не зависит от числа слоев ни от вида используемого клея. Примерно так же представляются прочность и деформации.
The respective investigations comprised the beech wood glued by layers, designed for selected constructional furniture elements. The aim of the investigations was to determine elastic properties of the wooden elements jointly with datermination of relationships between the elasticity modules of the by-layer glued elements of different number of layers, their thickness and bending direction. To attain this aim, theoretical investigations were carried out with their subselent verification on the basis of the experimental investigation results. The investigations have proved that the elasticity module of beech wood elements glued by layers does not depend on the number of layers and the glue kind used. Strength and deformations are formed similarly.
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 1990, 379
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stateczność ram stalowych z węzłami podatnymi
Stability of steel frames with bolted joints
Autorzy:
Litewka, P.
Bąk, M.
Powiązania:
https://bibliotekanauki.pl/articles/163542.pdf
Data publikacji:
2015
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
rama stalowa
analiza stateczności
węzeł podatny
sztywność konstrukcji
steel frame
stability analysis
flexible joint
structural rigidity
Opis:
Dotychczasowa praktyka projektowa związana z zagadnieniami stateczności opiera się na wyznaczeniu długości wyboczeniowej elementów ściskanych. Zastosowanie węzłów podatnych prowadzi często do wzrostu znaczenia stateczności, ze względu na obniżenie sztywności układu. Możliwe jest wówczas wykorzystywanie metody współczynnika długości wyboczeniowej, np. w oparciu o prace Giżejowskiego [1], analiza stateczności piętra ramy [2] lub analiza ogólna, wykorzystująca metodę elementów skończonych. Artykuł przedstawia przykład obliczeń stateczności dla kilku wariantów zastosowanych połączeń elementów, w celu określenia wpływu ich charakterystyk na stateczność konstrukcji. W obliczeniach uwzględniono chwilową sztywność połączeń uzyskaną z analizy nieliniowej dla podstawowego układu obciążeń. Uzyskane wyniki podkreślają znaczenie zagadnień stateczności w przypadku zamiany połączeń sztywnych na połączenia podatne.
The design practices implemented so far, within the area of stability, is based on determination of the buckling length of the elements which are pressed against one another. Using the bolted joints often leads to an increase in stability, since rigidity of the structure is being reduced. In such case it is possible to implement the methodology based on the buckling length coefficient, based e.g. on the studies developed by Giżejowski [1], analysis of stability of the frame floor [2] or general analysis, using the finite elements method. The article presents an example of stability calculations for several variants of the utilized joints between the individual elements of the structure. The aim of the calculations is to define the impact of the characteristics of those elements on the structural stability. The calculations took into account the rigidity of the joints, achieved via a non-linear analysis for the basic load imposition layout. The obtained results emphasize the meaning of the stability issues, when it comes to change of the rigid joints to the bolted ones.
Źródło:
Przegląd Budowlany; 2015, R. 86, nr 10, 10; 42-47
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Welded joint assessment on the basis of an algorithm of characteristic edge detection
Ocena poprawności wykonania złącz spawanych z zastosowaniem algorytmu detekcji krawędzi
Autorzy:
Bzymek, A.
Timofiejczuk, A.
Powiązania:
https://bibliotekanauki.pl/articles/329602.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
poprawność wykonania
złącze spawane
analiza obrazu
detekcja krawędzi
quality assessment
welded joint
image analysis
edge detection
Opis:
Research presented in the paper concerns a part of the software applied in a vision system designed for welding process diagnostics. In the system one infrared camera and two CCDs were applied. All procedures included in the image analysis module were limited to operations performed within distinguished ROIs (Region Of Interest), the areas around ROIs were omitted. The goal of the analysis was to obtain series of image features that could be a background for recognition abnormalities of the welding process and faults of the weld. Procedures elaborated within the framework of the described research were focused on the application of two algorithms realized correspondingly, they were: scanning operations, and procedures of identifying characteristic edges of the welded joints. Presented research were elaborated in Department of Fundamentals of Machinery Design of Silesian University of Technology within the framework of PW-004/ITE/10/2006 project.
Prezentowane badania dotyczą części oprogramowania opracowanego dla celów systemu przeznaczonego do diagnostyki procesu spawania. System składa się m.in. z dwóch kamer CCD i jednej kamery termowizyjnej. Na podstawie analizy wyróżnionych obszarów zainteresowania (ROI) ze zdjęć rejestrowanych w trakcie procesu spawania, wyznaczono zbiór cech, które mogą stanowić podstawę do wnioskowania o niezgodnościach spawalniczych powstających podczas spawania oraz o stabilności procesu. Wyniku przeprowadzonych badań opracowane zostały dwa algorytmy: tzw. skanowania połączenia w celu wyznaczania profilu jasności oraz procedury umożliwiające identyfikację krawędzi charakterystycznych dla konkretnych niezgodności. Badania zostały przeprowadzone w Katedrze Podstaw Konstrukcji Maszyn w ramach projektu PW-004/ITE/10/2006.
Źródło:
Diagnostyka; 2010, 2(54); 29-36
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przedkliniczne testy endoprotez stawu biodrowego z wykorzystaniem metody elementów skończonych
Preclinical tests of endoprostheses of hip joint using finite element methods
Autorzy:
Ryniewicz, A. M.
Madej, T.
Powiązania:
https://bibliotekanauki.pl/articles/283783.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
biomateriały
endoprotezy
tomografia komputerowa
staw biodrowy
modelowanie
analiza
biomaterials
endoprosthesis
computer tomography
hip joint
modeling
analysis
Opis:
W opracowaniu przedstawiono metodę wykonania testów przedklinicznych w aplikacjach endoprotezy stawu biodrowego w układzie anatomicznym. Metoda polegała na modelowaniu różnych konstrukcji endoprotez wykonanych z różnych biomateriałów i wirtualnym osadzaniu, w odwzorowanych na podstawie tomografii komputerowej (CT), strukturach kostnych. Wykorzystanie metody elementów skończonych pozwoliło na przeprowadzenie analiz numerycznych w zamodelowanych obiektach badań. W warunkach przenoszenia obciążeń lokomocyjnych dokonywana była wizualizacja rozkładów naprężeń, przemieszczeń i odkształceń w endoprotezie, kości miednicznej oraz w bliższym końcu kości udowej. Wyniki badań pozwoliły porównać rozwiązania konstrukcyjne endoprotez stawu biodrowego oraz ocenić charakter oddziaływania sztucznego stawu na otaczające tkanki kostne w warunkach indywidualnego pacjenta.
The method of preclinical tests in application of endoprostheses of hip joint in the anatomical system is presented in this elaboration. The method is based on the modeling of different constructions of endoprostheses made from different biomaterials. The endoprostheses were virtually placed in natural bone structures and obtained from the computer tomography diagnostic (CT). The use of the finite element method allowed to carry on numerical analyses in modeled objects of tests. The visualization of distribution of stresses, displacements and deformations in endoprostheses, pelvis bone and femoral bone was conducted in the conditions of transfer of load. The results of tests let to compare the construction solutions of endoprostheses of hip joint and estimate the interaction of artificial hip joint on the surrounding bone tissues in individual patientconditions.
Źródło:
Engineering of Biomaterials; 2010, 13, 94; 14-23
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and analysis of cementless hip-joint system using functionally graded material
Autorzy:
Asiri, Saeed
Powiązania:
https://bibliotekanauki.pl/articles/2065758.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
functionally graded material
cementless hip-joint system
natural frequency
harmonic response
fatigue analysis
finite element analysis
modal analysis
odpowiedź harmoniczna
analiza zmęczeniowa
analiza elementów skończonych
analiza modalna
Opis:
Functionally Graded Materials (FGM) are extensively employed for hip plant component material due to their certain properties in a specific design to achieve the requirements of the hip-joint system. Nevertheless, if there are similar properties, it doesn’t necessarily indicate that the knee plant is efficiently and effectively working. Therefore, it is important to develop an ideal design of functionally graded material femoral components that can be used for a long period. A new ideal design of femoral prosthesis can be introduced using functionally graded fiber polymer (FGFP) which will reduce the stress shielding and the corresponding stresses present over the interface. Herein, modal analysis of the complete hip plant part is carried out, which is the main factor and to date, very few research studies have been found on it. Moreover, this enhances the life of hip replacement, and the modal, harmonic, and fatigue analysis determines the pre-loading failure phenomena due to the vibrational response of the hip. This study deals with the cementless hip plant applying the finite element analysis (FEA) model in which geometry is studied, and the femoral bone model is based in a 3D scan.
Źródło:
Archive of Mechanical Engineering; 2022, LXIX, 1; 129--146
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modern hybrid joints in arospace: modelling and testing
Nowoczesne połączenia hybrydowe w Lotnictwie: modelowanie i badania eskperymentalne
Autorzy:
Sadowski, T.
Balawender, T.
Śliwa, R.
Golewski, P.
Kneć, M.
Powiązania:
https://bibliotekanauki.pl/articles/350876.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
zaciskanie
połączenia hybrydowe
połączenie nit-klej
połączenie klincz-klej
połączenie zgrzewanie punktowe-klejenie
analiza elementów skończonych
system cyfrowej korelacji obrazu
clinching
hybrid joint
rivet-adhesive bonded joint
clinch - adhesive joint
spot welding - adhesive joint
FEA (finite element analysis)
DIC (digital image correlation system)
Opis:
The aim of the paper is to review different types of modern hybrid joints applied in aerospace. We focused on three particular cases: 1) spot welding - adhesive, 2) rivet-bonded and 3) clinch-bonded joints. The numerical models presented in the paper for these joints describe their complex behaviour under mechanical loading. The numerical calculations performed using ABAQUS code were compared to experimental results obtained by application of the Digital Image Correlation system (DIC) ARAMIS. The results investigated within the paper lead to the following major conclusions: - the strengthening of joints by application of adhesive significantly improve static strength, - the final failure of the joined structural system significantly depends on the surface adhesive area, - the stiffening effects of the hybrid joint lead to higher reliability and durability of the structural joints.
W pracy dokonano przeglądu różnych typów połączeń hybrydowych stosowanych w lotnictwie. Szczególną uwagę zwrócono na trzy typy połączeń: 1) zgrzewanie punktowe - klejenie, 2) nitowanie - klejenie, 3) klinczowanie - klejenie. Modele numeryczne złączy zawarte w pracy, ujawniają złożoną i trudną do przewidzenia reakcję tych złączy na obciążenia mechaniczne. Obliczenia numeryczne porównano z wynikami eksperymentalnymi otrzymanymi za pomocą bezdotykowego systemu pomiaru odkształcen i naprężeń (DIC) ARAMIS. Główne wnioski z prezentowanych badań: - zastosowanie kleju powoduje istotne zwiększenie wytrzymałości statycznej testowanych połączeń, - na końcowy efekt zniszczenia złącza hybrydowego znaczący wpływ ma powierzchnia złącza klejowego, - zwiększona sztywność złączy hybrydowych powoduje, że mają one większą niezawodność i trwałość jako połączenia konstrukcyjne.
Źródło:
Archives of Metallurgy and Materials; 2013, 58, 1; 163-169
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
3D kinematic analysis of patients’ gait before and after unilateral total hip replacement
Autorzy:
Kolářová, Kateřina
Vodička, Tomáš
Bozděch, Michal
Repko, Martin
Powiązania:
https://bibliotekanauki.pl/articles/27324147.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
hip joint
arthrosis
THR
3D kinematics
gait analysis
staw biodrowy
artroza
kinematyka 3D
analiza chodu
Opis:
Purpose: The purpose of the study was to describe changes in the kinematic parameters in the patients’ gait after total hip replacement. Methods: Research group of men in the end stage of osteoarthritis indicated to the THR (n = 10; age 54.1 ± 7.5 years; weight 92.2 ± 9.6 kg; height 179.7 ± 5.9 cm). All participants underwent a total of three measurements: before surgery, 3 and 6 months after the surgery. Using the 3D kinematic analysis system, the patients’ gait was recorded during each measurement session and kinematic analysis was carried out. The parameters that were monitored included the sagittal range of motion while walking in the ankle, the knee and the hip joints of the operated and the unoperated limb, and the range in the hip joint’s frontal plane, the rotation of pelvis in the frontal and transverse planes, as well as the speed of walking and the walking step length. Results: Significant increases were found in sagittal range of motion in the operated hip joint, sagittal range of motion in the ankle joint on the unoperated side and in the walking step length of the unoperated limb. Conclusions: During walking after a THR, the sagittal range of motion in the ankle of the unoperated limb increases. Also, the range of motion in the sagittal plane on the operated joint increases, which is related to the lengthening of the step of the unoperated lower limb.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 2; 165--171
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite element modelling of the behaviour of a certain class of composite steel-concrete beam-to-column joints
Skończenie-elementowe modelowanie zachowania się pewnej klasy węzłów zespolonych stalowo-betonowych w połączeniach rygli ze słupami
Autorzy:
Giżejowski, M. A.
Barcewicz, W.
Salah, W.
Powiązania:
https://bibliotekanauki.pl/articles/231473.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analiza nieliniowa
metoda elementów skończonych
zachowanie niesprężyste
węzeł zespolony stalowo-betonowy
połączenie rygiel-słup
composite steel-concrete joint
finite element model
nonlinear analysis
inelastic behaviour
beam-to-column joint
Opis:
Beam-to-column end-plate joints can be classified as rigid (fully restrained), semi-rigid (partially restrained) or pinned, depending on their type, configuration and the connector arrangement. Fully restrained joints are needed for rigid frames in which there is assumed that the frame joints have sufficient rigidity to maintain - under the service state - the angles between the intersecting members, ensuring the full moment transfer. In contrast in semi-continuous frames, partially restrained joints are characterized by relative rotations occurring between the intersecting members so that the bending moment can only be transferred partially. In recent years, the idea of using partially restrained, unstiffened joints in building structures has gained momentum since this idea appears to be more practical and economical. Semi-continuous frames can resist actions by the bending moment transfer in partially restrained joints, allowing in the same time for a certain degree of rotation that enhances the overall ductile performance of these structures. One of the effective ways that affects ductility of end-plate beam-to-column joints is to use thinner end-plates than those used nowadays in practical applications. In the current study, a certain class of steel-concrete composite joints is examined in which the thickness of end-plates is to be equivalent to approximately 40-60% of the bolt diameter used in all the composite joints investigated in the considered joint class. This paper is an extension of the authors' earlier investigation on numerical modelling of the behaviour of steel frame joints. The aim of current investigations is to develop as simple as possible and yet reliable three-dimensional (3D) FE model of the composite joint behaviour that is capable of capturing the important factors controlling the performance of steel-concrete end-plate joints in which the end-plate thickness is chosen to be lesser than that used nowadays in conventional joint detailing. A 3D FE model constructed for composite joints of the considered joint class is reported in this paper and numerical' simulations using the ABAQUS computer code are validated against experimental investigations conducted at the Warsaw University of Technology. Comparison between the nonlinear FE analysis and full scale experimental results of the considered class of composite joints is presented which conclusively allows for the accuracy assessment of the modelling technique developed. Comparison between the FE results and test data shows a reasonable agreement between the numerical FE model developed and physical model of experimentally examined joint specimens. Finally, practical conclusions for engineering applications are drawn.
Węzły w konstrukcjach ramowych można sklasyfikować jako sztywne (o pełnej nośności), podatne (o niepełnej nośności) lub nominalnie przegubowe, w zależności od ich typu, konfiguracji i rozmieszczenia łączników. Węzły o pełnej nośności są wymagane dla ram sztywnych, w których założono, że węzły zapewniają pełne przeniesienie momentów zginających z rygli na słupy. Natomiast w ramach z węzłami podatnymi o niepełnej nośności, węzły są charakteryzowane przez względne obroty pojawiające się pomiędzy łączonymi elementami tak, że moment zginający może być przeniesiony tylko częściowo. W ostatnich latach, idea wykorzystania bezżebrowych węzłów podatnych zyskuje coraz większe zastosowanie w praktyce inżynierskiej. Ramy niepełnociągłe mogą przeciwstawiać się oddziaływaniom dzięki węzłom podatnym o niepełnej nośności, które przenoszą momenty zginające przy jednoczesnym pojawieniu się lokalnego obrotu elementów przerwanych w węźle. Jednym z efektywnych sposobów zwiększających ciągliwość węzłów typu rygiel-słup z blachami czołowymi jest zastosowanie blach o grubości mniejszej niż stosowana obecnie w praktyce inżynierskiej. W niniejszej pracy, poddano analizie grupę węzłów zespolonych stalowo-betonowych, w których grubość blachy czołowej stanowi około 40-60% średnicy śrub. Praca stanowi rozwinięcie zagadnień opracowanych przez autorów w powoływanych pracach wcześniejszych i dotyczących numerycznego modelowania zachowania się węzłów stalowych w konstrukcjach ramowych. Celem rozważań jest znalezienie prostego i jednocześnie wystarczająco dokładnego modelu 3D zachowania się węzła zespolonego, uwzględniąjącego najistotniejsze czynniki wpływające na zachowanie się stalowo-betonowych węzłów doczołowych z blachami o grubościach mniejszych niż stosowane w rozwiązaniach konwencjonalnych. Przedstawiono model 3D skonstruowany dla rozważanego typu węzłów zespolonych, przy wykorzystaniu systemu ABAQUS oraz porównano wyniki symulacji numerycznych z wynikami badań doświadczalnych przeprowadzonych w Politechnice Warszawskiej. Porównanie wyników nieliniowego modelu skończenie-elementowego z wynikami badań doświadczalnych węzłów zespolonych w skali technicznej, świadczy o poprawności przyjętej techniki modelowania, jak również o zadowalającej zgodności modelu numerycznego z modelem fizycznym elementów badanych doświadczalnie. Na zakończenie podano praktyczne uwagi dotyczące innowacyjnego kształtowania i projektowania rozpatrywanej klasy węzłów zespolonych.
Źródło:
Archives of Civil Engineering; 2010, 56, 1; 19-56
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczenie parametrów ruchów przestrzennych za pomocą jednej kamery wideo
Calculation of kinematic parameters of three - dimensional movements with help of one video camera
Autorzy:
Dobosz, D.
Sobota, G.
Powiązania:
https://bibliotekanauki.pl/articles/99253.pdf
Data publikacji:
2009
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
biomechanika
analiza ruchu
parametry kinematyczne
staw ramienny
kamera wideo
biomechanics
motion analysis
kinematical parameters
shoulder joint
video camera
Opis:
Celem pracy była próba wyznaczenia parametrów kinematycznych ruchów zachodzących w przestrzeni trójwymiarowej przy użycie prostych technik wideo. Wychodząc naprzeciw potrzebie rejestrowania i analizy złożonego aktu ruchowego opracowano systemy takie jak VICON, SMART BTS czy QUALISYS. Dzięki zastosowaniu więcej niż jednej kamery umożliwiają one badanie ruchu przestrzennego we wszystkich płaszczyznach z dużą dokładnością. W pracy zaproponowano algorytm pozwalający na wykorzystanie tylko jednej kamery wideo do wyznaczenia parametrów kinematycznych w innej płaszczyźnie niż płaszczyzna kamery, stosując dodatkowo informacje o parametrach antropometrycznych ciała człowieka. Praktyczne zastosowanie przetestowano dla badania kinematyki ruchu wyciskania sztangi na zawodnikach wysokiej klasy AWF Katowice.
The goal of the paper is to try to point out the kinematical parameters of movements which take place in three - dimensional space by using simple video technique. To record and analyze the complicated body movement different systems such as VICON, Smart BTS or Qualisys have been worked out. With the use of more than one camera this programs enable us to study spatial movements in all plains with high precision. The Authors propose employing an algorithm which let us point out kinematical parameters in a plain other than the recording one, additionally using some information about anthropometric parameters of human body. The handiness of this method was tested during doing researches about kinematic of lifting. The people who participate in researches were high rang competitors from AWF Katowice.
Źródło:
Aktualne Problemy Biomechaniki; 2009, 3; 29-34
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ligament-based spine-segment mechanisms
Autorzy:
Ciszkiewicz, A.
Milewski, G.
Powiązania:
https://bibliotekanauki.pl/articles/202123.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
intervertebral joint
optimization
parameters estimation
genetic algorithm
elastostatic analysis
staw międzykręgowy
optymalizacja
szacowanie parametrów
algorytm genetyczny
analiza elastostatyczna
Opis:
Nowadays, a growing interest in spine-segment mechanisms for humanoid robots can be observed. The ones currently available are mostly inspired by an intervertebral joint but rarely use its structure and behaviour as input data. The aim of this study was to propose and verify an approach to spine-segment mechanisms synthesis, in which the mechanisms were obtained directly from a ligament system of the intervertebral joint through numerical optimization. The approach consists of two independent optimization procedures performed with genetic algorithm. The first one searches for the optimal structure, while the second estimates its geometrical and stiffness parameters. The mechanisms are rated by their ability to reproduce the static behaviour of the joint in selected aspects. Both procedures use the lumbar L4-L5 intervertebral joint reference data. The approach was tested in two numerical scenarios. It was possible to obtain a mechanism with 7 flexible linear legs that accurately emulated the elastostatic behaviour of the intervertebral joint under moment loads. The results prove that the proposed method is feasible and worth exploring. It may be employed in design of bioinspired joints for use in humanoid robots and can also serve as an initial step in the design of prosthetic and orthotic devices for a human spine.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2018, 66, 5; 705-712
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Influence of Geometrical Parameters of the Lock of the Blade-Disc Joint on Stress in the FEA and DIC Methods
Autorzy:
Kozakiewicz, Adam
Grzejszczak, Olga
Powiązania:
https://bibliotekanauki.pl/articles/2024072.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
parameterization
strength analysis
dovetail joint
DIC
FEA
stress distribution
parametryzacja
analiza wytrzymałościowa
połączenie na jaskółczy ogon
rozkład naprężeń
Opis:
In this paper, an assessment of strength properties of the existing blade-disc dovetail joint was presented, taking the parametric optimization of its geometry. A sensitivity of the analysis was carried out to determine the relationship between the selected geometric parameters and strength properties of the structure questioned. The results from experiments and computer simulations were compared. In addition, the fatigue life of the structure was analyzed for different materials and using the change of speed ranges and parameterization of geometry.
Źródło:
Advances in Science and Technology. Research Journal; 2021, 15, 1; 209-217
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomechanical characterization of slope walking using musculoskeletal model simulation
Autorzy:
Masayuki, K.
Hata, K.
Kiyama, R.
Maeda, T.
Yone, K.
Powiązania:
https://bibliotekanauki.pl/articles/307044.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
analiza lokomocji
chód
choroba zwyrodnieniowa stawów
układ mięśniowo-szkieletowy
gait analysis
slope walking
osteoarthrosis
joint force
musculoskeletal model simulation
Opis:
Upslope and downslope walking are basic activities necessary for normal daily living in community, and they impose greater joint load on the lower extremities than during level walking. Thus, the purpose of this study was to quantify the resultant and shear forces in the hip and knee joints during slope walking. Methods: Twelve healthy volunteers were evaluated when walking under level and 10° up- and downslope conditions. Three-dimensional gait analysis was conducted using a 7-camera optoelectronic motion analysis system combined with a force plate to measure ground reactive force. Joint forces in the hip and knee joints were estimated using musculoskeletal model simulation. Results: Results showed that the resultant hip force was increased significantly to 117.2% and 126.9%, and the resultant knee force was increased to 133.5% and 144.5% in up- and downslope walking, respectively, compared to that of level walking. Furthermore, increased shear force in the hip and knee joints was noted during both slope walking conditions. Conclusions: This information may be beneficial for therapists advising elderly people or patients with osteoarthrosis on an appropriate gait pattern, gait assistive devices, or orthoses according to their living environment.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 1; 117-125
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies