Tytuł:
Recent simulation results of the magnetic induction tomography forward problem
Autorzy:
Stawicki, K.
Szuflitowska, B.
Ziolkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/141095.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
boundary conditions
eddy current testing
finite element method
magnetic
induction tomography
Opis:
In this paper we present the results of simulations of the Magnetic Induction Tomography (MIT) forward problem. Two complementary calculation techniques have been implemented and coupled, namely: the finite element method (applied in commercial software Comsol Multiphysics) and the second, algebraic manipulations on basic relationships of electromagnetism in Matlab. The developed combination saves a lot of time and makes a better use of the available computer resources.
Źródło:
Archives of Electrical Engineering; 2016, 65, 2; 327-336
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical aspects of the secondary magnetic field mapping in Magnetic Induction Tomography
Numeryczne aspekty odwzorowania wtórnego pola magnetycznego w Magnetycznej Tomografii Indukcyjnej
Autorzy:
Szuflitowska, B.
Ziolkowski, M.
Stawicki, K.
Powiązania:
https://bibliotekanauki.pl/articles/408766.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
magnetic induction tomography
eddy current
forward problem
electrical conductivity
magnetyczna tomografia indukcyjna
prąd wirowy
zagadnienie proste
konduktywność elektryczna
Opis:
Magnetic Induction Tomography (MIT) belongs to the noncontact electromagnetic imaging techniques. This paper focuses on determination of a secondary magnetic field map calculated with the help of the Biot-Savart law around the low-conductivity object. The inclusions of various shapes and different electrical conductivities values and two measurement planes are considered. In each case the objects’ single maximal cell volume with assumed uniform eddy current density has been determined. In order to keep the relative error below 1% the object should be divided in most cases into elements with maximal cell volume equal to 0.244 mm3 for yz − plane, and 0.03 mm3 for xy − plane.
Magnetyczna Tomografia Indukcyjna (MIT) należy do bezkontaktowych, elektromagnetycznych technik obrazowania. Artykuł skupia się na wyznaczeniu mapy wtórnego pola magnetycznego obliczonego za pomocą prawa Biota-Savarta wokół obiektu słaboprzewodzącego. Przeanalizowano wtrącenia o różnym kształcie i różnej wartości konduktywności elektrycznej oraz dwie płaszczyzny pomiarowe. W każdym przypadku została wyznaczona maksymalna objętość pojedynczej komórki obiektu z założoną stałą wartością gęstości prądu. W celu uzyskania błędu względnego poniżej 1% obiekt powinien zostać podzielony w większości przypadków na elementy z maksymalną objętością równą 0,244 mm3 dla płaszczyzny yz oraz 0,03 mm3 dla płaszczyzny xy.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 3; 11-14
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computerized Systems for Electromagnetic Nondestructive Testing
Skomputeryzowane Systemy do Elektromagnetycznych Badań Nieniszczących
Autorzy:
Chady, T.
Gratkowski, T.
Komorowski, M.
Kowalczyk, J.
Pałka, J.
Psuj, G.
Powiązania:
https://bibliotekanauki.pl/articles/156986.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
elektromagnetyczne metody badań nieniszczących
magnetyczna tomografia indukcyjna
electromagnetic nondestructive testing methods
eddy current method
magnetic flux leakage method
Barkhausen noise
magnetic induction tomography
Opis:
In this paper computerized systems for electromagnetic nondestructive testing of well- and low-conducting materials are presented. Several different inspection methods: the eddy current method, the magnetic flux leakage, the Barkhausen noise, and the AC magnetization measurement are described. Finally, the magnetic induction tomography system for evaluation of low-conductivity materials has been presented.
W niniejszym artykule przedstawiono skomputeryzowane układy do elektromagnetycznych badań nieniszczących materiałów dobrze- i słabo-przewodzących. Opisano kilka różnych metod badawczych: metodę prądów wirowych, strumienia rozproszenia, szumów Barkhausena oraz obserwacji procesu magnesowania. Zaprezentowano układ magnetycznej tomografii indukcyjnej do oceny materiałów słabo-przewodzących.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 6, 6; 26-29
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetoacoustic tomography with magnetic induction for low conductivity objects
Tomografia magnetoakustyczna ze wzbudzeniem indukcyjnym do badania obiektów o niskiej konduktywności
Autorzy:
Cichoń-Bańkowska, K.
Ziółkowski, M.
Gratkowski, S.
Stawicki, K.
Brykalski, A.
Szymanik, B.
Żywica, A.
Powiązania:
https://bibliotekanauki.pl/articles/261327.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
magnetoacoustic tomography
magnetic induction
conductivity imaging of biological structures
tomografia magnetoakustyczna
wzbudzenie indukcyjne
obrazowanie konduktywności struktur biologicznych
Opis:
This paper presents a new promising non-invasive electrical conductivity imaging method of low-conductivity objects (e.g. biological tissues), called Magneto-Acoustic Tomography with Magnetic Induction (MAT-MI). The described method combines ultrasound and magnetism into one unified hybrid technique. The object is placed in a static and a pulsed (μs) magnetic field. The time-varying (pulsed) magnetic field induces eddy currents in the object. Consequently, the object emit ultrasonic waves through the Lorentz force produced by the combination of the eddy current and the static magnetic field. The ultrasonic waves are then collected by the detectors located around the object for image reconstruction. MAT-MI combines the good contrast of Electrical Impedance Tomography (EIT) with the good spatial resolution of sonography. The aim of this paper is a review of theoretical studies of MAT-MI and discussion of possible future research directions.
W pracy opisano nową obiecującą metodę nieinwazyjnego obrazowania przewodności elektrycznej obiektów słabo przewodzących (np. tkanek biologicznych) zwaną tomografią magnetoakustyczną ze wzbudzeniem indukcyjnym (ang. Magneto-Acoustic Tomography with Magnetic Induction – MAT-MI). Prezentowana metoda jest techniką hybrydową i łączy badania ultradźwiękowe z magnetyzmem. Badany obiekt umieszczony jest w statycznym oraz impulsowym (μs) polu magnetycznym. Zmienne pole magnetyczne indukuje w nim prądy wirowe. W wyniku działania sił Lorentza powstałych dzięki interakcji prądów wirowych oraz statycznego pola magnetycznego, obiekt będzie emitował fale ultradźwiękowe. Fale te są odbierane przez detektory umieszczone wokół obiektu. Metoda MAT-MI łączy dobry kontrast elektrycznej tomografii impedancyjnej (ang. Electrical Impedance Tomography – EIT) z dobrą rozdzielczością przestrzenną metody ultradźwiękowej. Celem niniejszej pracy jest przegląd badań teoretycznych metody MAT-MI oraz dyskusja przyszłych kierunków badawczych.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2014, 20, 4; 187-192
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the optimal scanning step for evaluation of image reconstruction quality in magnetoacoustic tomography with magnetic induction
Określenie optymalnego kroku skanowania do oceny jakości rekonstrukcji obrazu w tomografii magnetoakustycznej ze wzbudzeniem indukcyjnym
Autorzy:
Zywica, Adam Ryszard
Ziolkowski, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/408684.pdf
Data publikacji:
2019
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
image reconstruction
image processing algorithm
medical diagnostic imaging
magnetoacoustic effect
magnetoacoustic tomography with magnetic induction
rekonstrukcja obrazu
algorytm przetwarzania obrazu
diagnostyczne obrazowanie medyczne
efekt magnetoakustyczny
tomografia magnetoakustyczna ze wzbudzeniem indukcyjnym
Opis:
Magnetoacoustic Tomography with Magnetic Induction (MAT-MI) is a new hybrid imaging modality especially dedicated for non-invasive electrical conductivity imaging of low-conductivity objects such as e.g. biological tissues. The purpose of the present paper is to determine the optimal scanning step assuring the best quality of image reconstruction. In order to resolve this problem a special image reconstruction quality indicator based on binarisation has been applied. Taking into account different numbers of measuring points and various image processing algorithms, the conditions allowing successful image reconstruction have been provided in the paper. Finally, the image reconstruction examples for objects’ complex shapes have been analysed.
Tomografia magnetoakustyczna ze wzbudzeniem indukcyjnym (MAT-MI) to nowa hybrydowa technika obrazowania dedykowana szczególnie do nieinwazyjnego obrazowania obiektów o niskiej konduktywności elektrycznej, takich jak na przykład tkanki biologiczne. Celem niniejszej pracy jest określenie optymalnego kroku skanowania zapewniającego najlepszą jakość rekonstrukcji obrazu. W celu rozwiązania tego problemu zastosowano specjalny wskaźnik jakości rekonstrukcji obrazu bazujący na binaryzacji. W artykule przedstawiono warunki umożliwiające pomyślne zrekonstruowanie obrazu biorąc pod uwagę różną liczbę punktów pomiarowych oraz różne algorytmy przetwarzania obrazu. W końcowym etapie pracy przeanalizowano przykłady rekonstrukcji obrazu dla obiektów o bardziej złożonych kształtach.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2019, 9, 4; 38-42
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies