Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "heating plant" wg kryterium: Temat


Tytuł:
Properties of black and brown coal combustion products and possibilities of their use
Właściwości produktów spalania węgla kamiennego i brunatnego oraz możliwości ich wykorzystania
Autorzy:
Michalikova, F.
Brezani, I.
Sisol, M.
Stehlikova, B.
Skvarla, J.
Powiązania:
https://bibliotekanauki.pl/articles/970956.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
ash
combustion
power plant
heating plant
boiler
węgiel
popiół
spalanie
elektrownia
elektrociepłownia
kocioł
Opis:
This submission reviews the properties and possible utilization of solid wastes originating in the thermal power plants and heating plants as a by-product of brown and black coal combustion in the conditions of granulation, fusion and fluidized-bed fuel firing boilers. In order to choose appropriate utilization method of the ashes, knowledge of their petrologic composition, combustion method, as well as of their physical, chemical, mineralogical and technological properties is fundamental. Ashes are heterogeneous materials composite of particles with different properties affected by coal type and combustion temperature. Physical properties of ashes from individual boilers include: particle size distribution, mass, volumetric and bulk density, hardness, compactibility, frost resistance, frost susceptibility, optic, electric and magnetic properties, thermal conductivity, fusibility, morphology. Reactivity of ashes is affected by particle size distribution and surface area. Morphological properties of ashes depend primarily on combustion temperature, chemical composition and properties of coal, atmosphere in which the combustion takes place, combustion chamber construction and combustion process control. Black coal is combusted in fusion boilers at a temperature between 1400°C and 1600°C where ashes are partially up to fully molten. Morphology of inorganic particles is characteristic by its spherical shape and significantly lower surface area when compared to surface area of inorganic particles from granulation and fusion boilers. Brown coal is combusted in granulation boiler at temperatures 1100°C – 1300°C. Inorganic particles tend to be porous with higher surface area when compared to surface area of inorganic particles from combustion of black coal. Combustion temperature of coal in fluidized bed type boilers is 800°C – 850°C. Fluid ash particles from both black and brown coal preserve the shape of original coal particles, perforated structure prevail. Surface areas of ashes from individual boilers and products of their processing (froth flotation and magnetic separation) ranges from 1 to 33 m2·g-1; densities range from 0.95 to 2.65 and 4.65 g·cm-3 resp.
W artykule przedstawiono właściwości oraz przegląd możliwości wykorzystania stałych produktów spalania węgla kamiennego i brunatnego pochodzących z elektrowni i elektrociepłowni spalających paliwo w kotłach rusztowych, fluidalnych i komorowych. Przedstawiono właściwości fizyczne, chemiczne, mineralogiczne i technologiczne popiołów. Dla prawidłowego doboru metody utylizacji popiołów konieczna jest znajomość ich składu petrograficznego, metody spalania, oraz właściwości fizycznych, chemicznych, mineralogicznych. Popioły są niejednorodnym materiałem kompozytowym z składającym się z cząstek o różnych właściwościach, wynikających z typu węgla oraz warunków (temperatury) spalania. Właściwości fizyczne popiołów z poszczególnych kotłów to: rozkład wielkości cząstek, masa, objętość i gęstość nasypowa, twardość, zagęszczalność, mrozoodporność, wrażliwość na niskie temperatury, właściwości optyczne, elektryczne i magnetyczne, przewodnictwo cieplne, topliwości, i morfologia. Reaktywność popiołu wpływa na rozkład wielkości cząstek i ich powierzchnię. Właściwości morfologiczne popiołów zależą przede wszystkim od temperatury spalania, składu chemicznego i właściwości węgla, atmosfery, w której następuje spalanie, konstrukcji komory spalania oraz sposobu sterowania procesem spalania. Węgiel kamienny jest spalany w kotłach komorowych w temperaturze pomiędzy 1400°C a 1600°C, przy czym powstający popiół jest częściowo lub całkowicie stopiony. Cechą morfologiczną cząstek popiołu jest kulisty kształt i znacznie niższa powierzchnia w stosunku do powierzchni nieorganicznych cząstek powstających w kotłach rusztowych i fluidalnych Węgiel brunatny jest spalany w kotłach rusztowych w temperaturze 1100°C – 1300°C. Cząstki nieorganiczne są zazwyczaj porowate, mają większą powierzchnię, w porównaniu do powierzchni cząstek popiołu ze spalania węgla kamiennego. Temperatura spalania węgla w kotłach fluidalnych wynosi 800°C – 850°C. Cząsteczki popiołu lotnego zarówno z węgla kamiennego i brunatnego zachowują kształt pierwotnych cząstek węgla, z dominującą struktura porowatą. Powierzchniach popiołów z poszczególnych kotłów i produkty ich przeróbki (flotacji pianowej i separacji magnetycznej) charakteryzują się powierzchnią od 1 do 33 m2·g-1 i odpowiednio gęstością w zakresie od 0,95 do 2,65 i 4,65 g·cm-3.
Źródło:
Inżynieria Mineralna; 2013, R. 14, nr 2, 2; 7-14
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rational management of geothermal waters after their energetic use – preliminary results of the project Geotermia Mazowiecka SA
Racjonalna gospodarka wodami geotermalnymi po ich energetycznym wykorzystaniu – wstępne efekty projektu Geotermii Mazowieckiej SA
Autorzy:
Bujakowski, Wiesław
Bielec, Bogusław
Balcer, Marek
Powiązania:
https://bibliotekanauki.pl/articles/216425.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
geothermal water
Mszczonów
geothermal heating plant
drinking water
woda geotermalna
ciepłownia geotermalna
woda pitna
Opis:
Poland belongs to the countries with limited waters intended for drinking resources. To meet this problem, the Management Board of Geotermia Mazowiecka SA carries out activities to determine the possibilities of using exploited geothermal waters other than energy purposes. In addition to energy, the geothermal water is used for recreation and balneotherapy in “Termy Mszczonów” and for the production of drinking water for the local water supply system. Some water needs to be discharged into surface watercourses due to a lack of coherence of heating and water supply needs. For recognizing this problem innovative research project entitled: “The development of a method for injecting after energy-used geothermal waters into selected geological structures” was prepared and implemented as part of the Regional Operational Program of the Mazowieckie Voivodship for 2014–2020 (Priority Axis: Research and development activities of enterprises). This project has resulted in the launch of the installation pumping excess water to the quaternary sandy leyer. Based on the results from the first year of operation of the project, it can be assumed that it is possible to achieve nearly 100% reduction of water discharge and, consequently, the full use of producted geothermal waters. In summary, it can be stated that the geothermal plant in Mszczonów is a unique installation not only on the Polish but also international scale. The proof of this is not only the scale of rational use of water for energy purposes (cooling from 41°C to about 17°C), but also their development in other areas, for example in “Termy Mszczonów” and for the production of waters intended for drinking. The article presents the results of the first year (2019) of operation of the water injection system. During this period, in cooled water discharged into surface watercourse nearly 50% reduction was achieved.
Polska należy do krajów o ograniczonych zasobach wód pitnych. Wychodząc naprzeciw temu problemowi Zarząd Spółki Geotermia Mazowiecka SA prowadzi działania w kierunku określenia możliwości wykorzystania eksploatowanych wód geotermalnych innych niż cele energetyczne. Wody złożowe oprócz zagospodarowania do generacji ciepła wykorzystywane są do rekreacji i balneoterapii w Termach Mazowieckich oraz do celów wytwarzania wód pitnych w lokalnym systemie wodociągowym. Część wód musiała być odprowadzana do cieków powierzchniowych z powodu braku koherencji potrzeb ciepłowniczych i wodociągowych. Temu służył innowacyjny projekt badawczy pn.: „Opracowanie metody zatłaczania wykorzystanych energetycznie wód geotermalnych do wytypowanych struktur geologicznych” realizowany w ramach Regionalnego Programu Operacyjnego Województwa Mazowieckiego na lata 2014–2020. Projekt ten zaowocował uruchomieniem instalacji zatłaczania nadmiarowych energetycznie wód do czwartorzędowego poziomu piaszczystego. Na podstawie wyników z pierwszego roku funkcjonowania projektu można założyć, że możliwe jest osiągnięcie blisko 100% redukcji zrzutu wód i co się z tym wiąże pełne wykorzystanie eksploatowanych wód złożowych. Podsumowując można stwierdzić, że Zakład geotermalny funkcjonujący w Mszczonowie jest unikalną instalacją nie tylko w skali polskiej ale także międzynarodowej. Dowodem na to jest nie tylko skala racjonalnego wykorzystania wód do celów energetycznych (schłodzenie od 41°C do około 17°C), ale także zagospodarowanie ich w innych obszarach: w Termach Mszczonowskich i do produkcji wód pitnych z SUW i z płytkich zbiorników hydrogeologicznych. W artykule przestawiono wyniki pierwszego, 2019 roku, funkcjonowania systemu zatłaczania schłodzonych wód.
Źródło:
Gospodarka Surowcami Mineralnymi; 2020, 36, 1; 123-134
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena efektywności ekonomicznej źródeł ciepła przy użyciu analizy kosztu życia (LCC) na przykładzie ciepłowni geotermalnej
Economic analysis of a heat source using life cycle cost analysis (LCC): geothermal heating plant case study
Autorzy:
Studencka, J.
Powiązania:
https://bibliotekanauki.pl/articles/96473.pdf
Data publikacji:
2016
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
ocena cyklu życia (LCA)
koszt cyklu życia (LCC)
ciepłownia geotermalna
life cycle assessment (LCA)
life cycle costs (LCC)
geothermal heating plant
Opis:
Celem niniejszego opracowania jest pokazanie metody oceny ułatwiającej podjęcie decyzji i wskazanie kompromisowego, w sensie wielokryterialnym, rozwiązania systemu ciepłowniczego, który będzie spełniał jednocześnie oczekiwania w zakresie efektywności ekonomicznej oraz zapewniał ograniczony zakres wpływu na środowisko naturalne i zdrowie ludzkie. Zadaniem w realizacji założonego celu jest przedstawienie analizy efektywności kosztowej wzorowanej na metodzie Analizy Cyklu Życia (LCA), która polega na ocenie kosztów w całym cyklu życia projektu. Przedmiotem badań jest wyznaczenie wskaźnika kosztu całkowitego, który był kluczowy w analizie, jaką przeprowadzono dla różnych źródeł ciepła, w tym dla ciepłowni geotermalnej oraz ciepłowni konwencjonalnej opalanej węglem kamiennym, wskazując rozwiązanie korzystniejsze.
Economic analysis of renewable energy heating systems which focus only on investment and operational costs is unreliable. To address the problem the Life Cycle Cost (LCC) analysis is applied. The comparative calculations are carried out for a hard coal-fi red heating plant and for a heating plant which uses geothermal energy. The calculation led to obtaining a unit cost indicator.
Źródło:
Ekonomia i Środowisko; 2016, 2; 150-161
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of risk factors related to the production and use of alternative fuels
Identyfikacja czynników ryzyka związanych z wytwarzaniem i wykorzystaniem paliw alternatywnych
Autorzy:
Ivashchuk, Oleksandr
Łamasz, Bartosz
Iwaszczuk, Natalia
Powiązania:
https://bibliotekanauki.pl/articles/282893.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
waste
energy recovery
alternative fuel
risk
combined heat and power plant
heating plant
electricity and heat
odpad
odzysk energii
paliwo alternatywne
ryzyko
elektrociepłownia
ciepłownia
energia elektryczna i cieplna
Opis:
The article analyzes the risk factors related to the energy use of alternative fuels from waste. The essence of risk and its impact on economic activity in the area of waste management were discussed. Then, a risk assessment, on the example of waste fractions used for the production of alternative fuel, was carried out. In addition, the benefits for the society and the environment from the processing of alternative fuels for energy purposes, including, among others: reducing the cost of waste disposal, limiting the negative impact on water, soil and air, reducing the amount of waste deposited, acquisition of land; reduction of the greenhouse effect, facilitating the recycling of other fractions, recovery of electricity and heat, and saving conventional energy carriers, were determined. The analysis of risk factors is carried out separately for plants processing waste for alternative fuel production and plants producing energy from this type of fuel. Waste processing plants should pay attention to investment, market (price, interest rate, and currency), business climate, political, and legal risks, as well as weather, seasonal, logistic, technological, and loss of profitability or bankruptcy risks. Similar risks are observed in the case of energy companies, as they operate in the same external environment. Moreover, internal risks may be similar; however, the specific nature of the operation of each enterprise should be taken into account. Energy companies should pay particular attention to the various types of costs that may threaten the stability of operation, especially in the case of regulated energy prices. The risk associated with the inadequate quality of the supplied and stored fuels is important. This risk may disrupt the technological process and reduce the plant’s operational efficiency. Heating plants and combined heat and power plants should also not underestimate the non-catastrophic weather risk, which may lead to a decrease in heat demand and a reduction in business revenues. A comprehensive approach to risk should protect enterprises against possible losses due to various types of threats, including both external and internal threats.
W artykule dokonano analizy czynników ryzyka związanego z energetycznym wykorzystaniem paliw alternatywnych produkowanych na bazie odpadów. Omówiono kwestie istoty ryzyka oraz jego wpływu na działalność gospodarczą w obszarze zagospodarowania odpadów. Następnie dokonano oceny ryzyka na przykładzie frakcji odpadów stosowanych do produkcji paliwa alternatywnego. Wskazano również korzyści, jakie przynosi społeczeństwu i środowisku przetwarzanie ich w celach energetycznych, w tym m.in.: obniżenie kosztów unieszkodliwiania odpadów; ograniczenie negatywnego wpływu na wody, glebę i powietrze; zmniejszenie ilości i wielkości składowanych odpadów; pozyskanie terenów; zmniejszenie efektu cieplarnianego; ułatwienie recyklingu pozostałych frakcji; odzysk energii elektrycznej i cieplnej; oszczędność konwencjonalnych nośników energii. Analiza czynników ryzyka jest przeprowadzona oddzielnie dla zakładów przetwarzających odpady na paliwa alternatywne oraz zakładów wytwarzających energię z tego rodzaju paliw. Zakłady przetwarzające odpady powinny zwrócić uwagę na ryzyko inwestycyjne, rynkowe (cenowe, stopy procentowej, walutowe), koniunkturalne, polityczno-prawne i społeczne, a także ryzyko: pogodowe, sezonowe, logistyczne, technologiczne, utraty rentowności czy upadłości. Podobne ryzyka występują też w działalności zakładów energetycznych, ponieważ funkcjonują one w tym samym otoczeniu zewnętrznym. Również ryzyka o pochodzeniu wewnętrznym mogą być podobne, jednak należy uwzględniać specyfikę działalności każdego zakładu. W przedsiębiorstwach energetycznych szczególną uwagę należy zwrócić na zwiększenie różnego rodzaju kosztów, które może zagrozić stabilności funkcjonowania, zwłaszcza w sytuacji regulowanych cen energii. Ważne jest ryzyko związane z nieodpowiednią jakością dostarczanych i przechowywanych paliw, które może zakłócić proces technologiczny i zmniejszyć wydajność pracy zakładu. Ciepłownie i elektrociepłownie nie powinny też bagatelizować ryzyka pogodowego niekatastroficznego, którego konsekwencją jest spadek popytu na ciepło i zmniejszenie wpływów z działalności gospodarczej. Kompleksowe podejście do ryzyka powinno uchronić przedsiębiorstwa przed ewentualnymi stratami z tytułu różnego rodzaju zagrożeń, płynących zarówno z otoczenia zewnętrznego, jak i tkwiących wewnątrz zakładów produkcyjnych.
Źródło:
Polityka Energetyczna; 2019, 22, 1; 97-112
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The importance of modernizations in realization of sustainable development principles – a case study of the Heating Plant ‘Piast’ in Bieruń, Poland
ZNACZENIE MODERNIZACJI W REALIZACJI ZASAD ZRÓWNOWAŻONEGO ROZWOJU – NA PRZYKŁADZIE ZAKŁADU CIEPŁOWNICZEGO „PIAST” W BIERUNIU
Autorzy:
SZWEDA, Anna
Powiązania:
https://bibliotekanauki.pl/articles/435203.pdf
Data publikacji:
2013-03-01
Wydawca:
Uniwersytet Opolski
Tematy:
sustainable development
environment protection
energetics
heating plant
modernizations of power installations
air pollution emission
air quality
zrównoważony rozwój
ochrona środowiska
energetyka
zakład ciepłowniczy
modernizacje instalacji spalania węgla
emisja zanieczyszczeń
jakość powietrza
Opis:
The issue of environment protection has gained in importance recently in connection with progressive environmental decay, which is caused by a steady economic development and exploitative natural resource management. Energetics is one of the industries, which have a damaging influence on the environment, especially in the matter of air quality. Polish energetics is based on carbon-intensive fuels due to big coal reserves commanded by the country. Coal burning leads to air pollution emission of sulfur dioxide, carbon dioxide and particulate matter. Modernizations of power installations are one of the ways towards realization of sustainable development principles. The article is devoted to modernizations implemented in the Heating Plant ‘Piast’ based in Bieruń, Poland. The investments embraced modernizations of the heating boilers and gas-cleaning plants, which constitute the IPPC installations. The author presents research results concerning the influence of conducted modernizations on the amounts of air pollution emissions.
W związku z postępującą degradacją środowiska naturalnego, spowodowaną dynamicznym rozwojem gospodarczym oraz prowadzeniem rabunkowej gospodarki zasobami naturalnymi, kwestie związane z szeroko pojętą ochroną środowiska zyskały na znaczeniu. Energetyka stanowi jeden z najbardziej obciążających środowisko naturalne sektorów przemysłowych, w szczególności zaś w odniesieniu do jakości powietrza. Polski przemysł energetyczny opiera się głównie na paliwach węglowych, co spowodowane jest znaczną ilością posiadanych zasobów węgla. Instalacje energetycznego spalania węgla powodują emisje zanieczyszczeń, takich jak dwutlenek siarki, dwutlenek węgla oraz pyły. Zasady zrównoważonego rozwoju realizowane są m. in. na drodze modernizacji instalacji energetycznych. Niniejszy artykuł opisuje modernizacje instalacji energetycznego spalania węgla przeprowadzone w Zakładzie Ciepłowniczym „Piast” w Bieruniu. Podjęte działania inwestycyjne objęły modernizacje wszystkich kotłów oraz instalacji odpylania i odsiarczania spalin, składających się na instalację IPPC. Przedstawione modernizacje zestawione zostały z wielkościami emitowanych zanieczyszczeń w wybranym okresie badawczym.
Źródło:
Economic and Environmental Studies; 2018, 18, 1; 375-386
1642-2597
2081-8319
Pojawia się w:
Economic and Environmental Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagadnienie mocy w systemach ciepłowniczych - moc maksymalna, moc zamówiona, rezerwa mocy
Autorzy:
Bujalski, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/89303.pdf
Data publikacji:
2018
Wydawca:
Nowa Energia
Tematy:
elektrociepłownia
system ciepłowniczy
moc
power plant
heating system
power
Opis:
Ile wynosi moc ciepłownicza elektrociepłowni? Odpowiedź na postawione pytanie wydaje się być relatywnie prosta, ale tylko wtedy kiedy mówimy o mocy elektrycznej bloku. Trudniejszym zagadnieniem będzie określenie jego mocy ciepłowniczej. Prowadzący elektrociepłownię dążą do zapewnienia takich warunków przepływowych, aby uzyskać pożądany efekt. Tym efektem może być minimalizacja kosztów albo osiągnięcie maksymalnej mocy ciepłowniczej.
Źródło:
Nowa Energia; 2018, 1; 40-42
1899-0886
Pojawia się w:
Nowa Energia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of heat load in a biomass-fired boiler
Analiza obciążenia cieplnego w kotle opalanym biomasą
Autorzy:
Bartoszewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/172829.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biomasa
ciepłownia
kocioł ciepłowniczy
biomass
heat-generating plant
heating boiler
Opis:
This paper discusses an exemplary cooperation between a research center, industry and technical inspection authorities. The purpose of the investigations (carried out to find the failure of a biomass-fired boiler in a heating plant) is an analysis of the effect of operating water boiler conditions on the heat load of the heating surface. The analysis concerns the reasons for failure of the membrane heat exchanger of the water-gas type being a basic heating surface of the boiler burning biomass. During the operation of the boiler some cracks perforated the bottom and smoke tube endings occurred.
W artykule przedstawiono wyniki współpracy ośrodka naukowego, ciepłowni miejskiej i inspekcji technicznej realizowanych w celu wykrycia przyczyn awarii kotła opalanego biomasą. Przedstawiono wyniki analizy numerycznej oraz wizualizacji w ciepłowni w celu określenia tych przyczyn. Badania obejmowały analizę przepony wymiennika ciepła typu woda-spaliny, który stanowi podstawową powierzchnię wymiany ciepła w kotle spalającym biomasę. Przedstawione w pracy wnioski z analizy wskazują na przyczyny pęknięć płyty sitowej i końcówek płomieniówek wymiennika.
Źródło:
Archiwum Energetyki; 2011, 41, 1; 65-77
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessing the Solar Power Plant Efficiency Degradation Resulting from Heating
Autorzy:
Lavrik, A.
Yakovleva, E.
Lеskov, A.
Powiązania:
https://bibliotekanauki.pl/articles/124651.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
photoelectric module
PEM
solar power plant
performance coefficient
heating
cooling
Opis:
Renewable power sources (RPS) play an ever growing role in power production. With the green power cost decreasing, the RPS share (including hydro power plants) in power production grows fast. Using RPS in supplying power to various facilities reduces the CO2 emission into atmosphere, thus reducing the greenhouse effect and being a fundamental factor in fighting the global warming. Every type of RPS possesses certain drawbacks that need to be eliminated. RPS units do have disadvantages, too, including low efficiency coefficient, and low specific power. However, there is the need for specific technological conditions. The present work describes the issue of photoelectric module heating. Photoelectric module heating results in both lower output voltage and module aging acceleration. The present work offers the method for assessing the practicability of development and implementation of solar power cell module active cooling systems, based on the photoelectric module daily performance schedules, drawing on statistic meteorological data collected over many years, and also it presents the brief description of various methods for cooling photoelectric modules.
Źródło:
Journal of Ecological Engineering; 2018, 19, 3; 115-119
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heating value of seeds of leguminous plants and their mixes with seeds of tussock-grass subfamily cereals
Ciepło spalania nasion roślin strączkowych i ich mieszanek z ziarniakami zbóż z podrodziny wiechlinowatych
Autorzy:
Wcislo, G.
Zabinski, A.
Sadowska, U.
Powiązania:
https://bibliotekanauki.pl/articles/792621.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
leguminous plant
seed
cereal seed
combustion heat
heating value
yellow lupin
pea seed
plant biomass
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2013, 13, 2
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The determination of heating and cooling day values using degree-day method: tomato plant example
Autorzy:
Yucel, A.
Atilgan, A.
Oz, H.
Saltuk, B.
Powiązania:
https://bibliotekanauki.pl/articles/62259.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
determination
heating value
cooling value
degree days method
tomato plant
greenhouse
Opis:
Based on the amount and duration of external temperature, degree day values are determined according to whether the selected equilibrium temperature is lower or higher than the air temperature. Degree day values are calculated according to the fluctuations in ambient temperature. It can be understood whether heating or cooling systems are necessary within the calculated periods. In this study, the meteorological data of Antalya region dating back many years and the temperature values suggested according to the cultivation periods of tomato in greenhouse environment have been used as material. The daily average temperature values recorded for many years have been compared with the equilibrium temperature values selected for the tomato plant thereby calculating the heating and cooling day values for each cultivation period. Tomato cultivation in greenhouses is carried out in 2 periods in the region in spring and autumn. At the end of these two periods, it was determined that the heating degree days in autumn were determined to be higher than that in spring. Whereas cooling degree days were determined to be greater for autumn cultivation in comparison with that of spring cultivation. Information regarding the energy consumption of an agricultural structure can be obtained beforehand via the heating and cooling degree day values. It has been surmised that such studies will help in making estimations regarding the energy need of various agricultural structures as well as gaining insight in the planning of the design stages that are directly related to the energy consumption of the building such as heating, cooling and ventilation.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2014, IV/1
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modernisation of a coal-fired heating plant to switch to woodchips, in accordance with logistics principles
Modernizacja kotlowni weglowej na zrebki drewniane z uwzglednieniem zasad logistyki
Autorzy:
Tucki, K.
Sikora, M.
Powiązania:
https://bibliotekanauki.pl/articles/792837.pdf
Data publikacji:
2016
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
power generating plant
modernization
wood chip
switching
power engineering
renewable energy sector
biomass
energy plant
cost
heating season
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2016, 16, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of heating on antioxidative activity of rapeseed and evening primrose extracts
Autorzy:
Zadernowski, R.
Nowak-Polakowska, H.
Konopka, I.
Powiązania:
https://bibliotekanauki.pl/articles/1372684.pdf
Data publikacji:
1996
Wydawca:
Instytut Rozrodu Zwierząt i Badań Żywności Polskiej Akademii Nauk w Olsztynie
Tematy:
evening primrose
Oenothera biennis
heating
food technology
methanolic extract
natural antioxidant
plant oil
polyphenol
antioxidant activity
phenolic acid
plant
rapeseed
Opis:
The composition and effect of heating (60°-110°C) on antioxidative activity in plant oil of rapeseed (RE) and evening primrose (EPE) methanolic extracts were studied. Different phenolics characterized the extracts. The EPE contained about 10-fold higher amount of phenolics (862.2 g/kg extract) than RE; flavanols (683.8 g/kg) and proanthocyanidins (760.1 g/kg) prevailed in the former and phenolic acid derivatives in the latter. The phenolic compounds of both extracts differed with the fenolic acids composition. Sinapic acid prevailed in rapeseed phenolics and protocatechic and gentisic acids in evening primrose phenolics. Both extracts had generally similar antioxidative activity in the temperature ranging from 60°C to 80°C with the oil peroxide values from 3.5 mmol O/kg to 5.0 mmol O/kg compared to the range of 6.0-7.0 mmol O/kg in control oils. The temperatures above 80°C decreased the antioxidative activity of both extracts and even made them to be prooxidative.
Badano skład i wpływ temperatury (60-110°C) na właściwości przeciwutleniające ekstraktów metanolowych nasion rzepaku i wiesiołka. Stwierdzono, że olej tych nasion zawierał tokoferole, głównie α- i y-, w ilości 0,65 g/kg (rzepak) i 0,45 g/kg (wiesiołek) (tab. 1), a ekstrakty metanolowe nasion charakteryzowały się różnymi formami związków fenolowych. W porównaniu z ekstraktem rzepakowym, ekstrakt wiesiołka zawierał około 10-krotnie więcej związków fenolowych, wśród których dominowały flawanole i proantocyjanidyny (tab. 2). Kwasy fenolowe i ich pochodne dominowały w ekstrakcie rzepakowym. Związki fenolowe ekstraktów różniły się składem kwasów fenolowych (rys. 1). Ekstrakty metanolowe obu nasion wykazywały się generalnie taką samą aktywnością przeciwutleniającą (rys. 2). W temperaturze powyżej 80°C aktywność przeciwutleniająca ekstraktów zanikała lub nawet obserwowano przyśpieszenie procesu utleniania oleju roślinnego.
Źródło:
Polish Journal of Food and Nutrition Sciences; 1996, 05, 2; 13-21
1230-0322
2083-6007
Pojawia się w:
Polish Journal of Food and Nutrition Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena efektywności ekonomicznej wykorzystania pomp ciepła do pokrycia potrzeb cieplnych obiektów w średniej wielkości oczyszczalni ścieków
Evaluating the economic efficiency of using heat pumps to cover the heat energy requirements in middle-size sewage treatment plants
Autorzy:
Szul, T.
Powiązania:
https://bibliotekanauki.pl/articles/238811.pdf
Data publikacji:
2008
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczalnia ścieków
ścieki
pompa ciepła
ogrzewanie
klimatyzacja
sewage treatment plant
sewage
heat pump
heating
air conditioning
Opis:
Dokonano analizy celowości wykorzystania ciepła odpadowego ze ścieków oczyszczonych przy wykorzystaniu pomp ciepła do pokrycia potrzeb cieplnych oraz klimatyzacyjnych w obiektach w oczyszczalni ścieków. Rozpatrzono cztery warianty wykorzystania pomp ciepła w obiektach oczyszczalni, charakteryzujące się różnym stopniem pokrycia ich potrzeb cieplnych. Zastosowanie pomp ciepła w systemie grzewczym pozwala na pokrycie potrzeb cieplnych w zależności od przyjętego wariantu od ok. 10% do ok. 85%. Roczne oszczędności oczyszczalni z tytułu zastosowania pomp ciepła do ogrzewania obiektów w zależności od zastosowanego wariantu mogą wynieść 12-60%. Aby móc wybrać najlepszą z proponowanych opcji, przeprowadzono analizę finansową przedsięwzięcia, w której porównano nakłady inwestycyjne z korzyściami, jakie mogą one przynieść po wdrożeniu danego wariantu do realizacji.
Purposefulness of using waste heat from purified sewage by means of the heat pumps, to cover the heat energy and conditioning requirements in sewage treatment plant, was analysed. Four variants of heat pump application in the objects of sewage treatment plant were considered as characterized by different levels of covering heat energy requirements. Using of the heat pumps in a heating system enables - depending on the variant assumed - to cover from 10 to almost 85% of heat energy requirements. The annual savings of sewage treatment plant owing to heat pumps' use to heating the objects may range within 12-60%, depending on the variant applied. To select the optimum from proposed options the financial analysis of the project was carried out, where the investment outlays were compared with potential profits possible to obtain as a result of implementing given variant to realization.
Źródło:
Problemy Inżynierii Rolniczej; 2008, R. 16, nr 3, 3; 125-136
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simplified exergy analysis of ship heating systems with different heat carriers and with the recovery of waste heat
Autorzy:
Zeńczak, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/240490.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ship’s power plant
heating systems
heat carrier
exergy analysis
systemy siłowni okrętowych
systemy grzewcze
nośnik ciepła
analiza egzergii
Opis:
The application of waste heat from exhaust gas of ship’s main engines has become widely practiced as early as in the 1930s. Thus the increase of ship’s overall efficiency was improved. Nowadays all newly built ships of the 400 gross tonnage and above must have specified energy efficiency design index, which is a measure for CO2 emissions of the ship and its impact on the environment. Therefore, the design of waste heat recovery systems requires special attention. The use of these systems is one of the basic ways to reduce CO2 emissions and to improve the ship’s energy efficiency. The paper describes the ship’s heating systems designed for the use of waste heat contained in the exhaust gas of self-ignition engines, in which the heat carriers are respectively water vapor, water or thermal oil. Selected results of comparative exergy analysis of simplified steam, water and oil heating systems have been presented. The results indicate that the oil heating system is comparable to the water system in terms of internal exergy losses. However, larger losses of exergy occur in the case of a steam system. In the steam system, a significant loss is caused by the need to cool the condensate to avoid cavitation in boiler feed pumps. This loss can in many cases cause the negative heat balance of ship during sea voyage while using only the exhaust gas boilers.
Źródło:
Archives of Thermodynamics; 2019, 40, 3; 211-228
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies