Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "heat transfer conditions" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Performance Analysis of a Thermoelectric Cooler Placed between Two Thermoelectric Generators for Different Heat Transfer Conditions
Autorzy:
Alsaqoor, Sameh
Powiązania:
https://bibliotekanauki.pl/articles/24201669.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
thermoelectric cooler
sandwich TEC
TEG performance
thermoelectric generator
heat transfer conditions
enhancing power generation
low energy harvesting
renewable energy induction
Opis:
The thermoelectric cooler (TEC) and thermoelectric generator (TEG) modules have several appealing features, including fixed parts, high reliability, low maintenance costs, and seamless connection with other heating equipment, accompaniment, can be powered by a variety of low-energy renewable energy sources such as solar water/air collectors, ground heat exchangers or heat from biomass. The thermoelectric assembly was integrated into the TEC using the TEG in this study. A prototype was developed in which recently developed thermoelectric modules were integrated into a thermoelectric cooler. For this purpose, a TEC sandwiched between two TEGs with different heat transfer conditions was established, to simulate the heat transfer and thermoelectric behavior of both the TEG and the TEC system, and evaluate the effect of the combined TEG-TEC on the performance parameters of the good system by comparing different cooling modes ranging from natural convection, forced convection, and water-cooling tests. It was shown that to the natural convection of heat transfer, as the TEC voltage increases, the hot surface temperature of the upper TEG increases, and the cold surface temperature of the lower TEG decreases, where the lowest TEC temperature reaches 1.36 A. When using forced convection (by using a fan), the temperature profile decreases over time, starting at around 70 °C for 7V, and after almost 60 minutes, the temperature drops to around 45 °C for 3V. This turned out to be a match between experiment and theory in all traces shown, with a voltage difference of 25 mV for 3V TEC and ending at 70 mV for 8V TEC.
Źródło:
Journal of Ecological Engineering; 2023, 24, 4; 27--35
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of heat transfer boundary conditions on the temperature field of the continuous casting ingot
Analiza wpływu warunków brzegowych na pole temperatury wlewka ciągłego
Autorzy:
Malinowski, Z.
Telejko, M.
Hadała, B.
Powiązania:
https://bibliotekanauki.pl/articles/354594.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wymiana ciepła
warunki brzegowe
odlewanie ciągłe
heat transfer
boundary conditions
continuous casting
Opis:
Steel solidification in the continuous casting process starts in the mould, follows in the secondary cooling zones and finishes under air cooling conditions. Casting technology requires very effective heat transfer from the strand surface to the water cooling system. Design and control of the casting process is possible if the ingot temperature is known with a suitable accuracy. Measurements of the ingot temperature are complicated and expensive and due to these reasons are not common in practice. Numerical simulation have to be used to provide data which can be used to design and control of the ingot solidification. In the case of the temperature field modeling heat transfer boundary conditions have to be specified. In the literature wide range of formulas can be found and this may lead to essential errors in the heat transfer coefficient determination. In the paper the selected formulas have been employed in the finite element model to compute the ingot temperature field in the mould and secondary cooling zones. It has been shown that inaccurate determination of the heat flux transferred from the ingot surface to the mould leads to essential errors in the determination of the ingot temperature and solidification. Therefore empirical formulas or complex heat transfer models at ingot - mould interface ought to be employed in finite element models.
Krzepnięcie stali w procesie ciągłego odlewania zachodzi w krystalizatorze i strefie chłodzenia wtónego. Technologia narzuca konieczność bardzo intensywnego odprowadzania ciepła od ciekłej stali, warstwy krzepnącej i zakrzepłej stali. Do prawidłowego prowadzenia odlewania konieczna jest znajomość wielu parametrów technologicznych, z których jednym z najważniejszych jest temperatura wlewka ciągłego. Bezpośrednie pomiary charakterystycznych dla COS wielkości w czasie krzepnięcia i stygnięcia wlewka są bardzo kosztowne oraz czasochłonne i z tych powodów nie znajdują szerszego zastosowania praktycznego. Najczęściej dane do analizy wpływu różnych parametrów wejściowych na proces krzepnięcia dostarczają symulacje numeryczne. Do prawidłowego ich wykonania potrzebne jest jednak określenie parametrów procesu. W przypadku temperatury bardzo ważną rolę odgrywają warunki brzegowe opisujące wymianę ciepła między powierzchnią wlewka ciągłego i otoczeniem. Ich niepoprawne przyjęcie może skutkować niedokładnym wyznaczeniem pola temperatury, a w konsekwencji błędami obliczeń pozostałych parametrów procesu. W literaturze często spotykane są różne formuły pozwalające na wyliczenie współczynnika przejmowania ciepła lub gęstości strumienia ciepła na powierzchni wlewka ciągłego. W pracy przedstawiono przykłady obliczeń pola temperatury dla wybranych zależności opisujących wymianę ciepła wlewka z otoczeniem w strefie krystalizatora i chłodzenia wtórnego. Przedstawiono wyniki symulacji oraz ich analizę. Obliczenia wykonano z zastosowaniem autorskiego modelu matematycznego i numerycznego wymiany ciepła oraz oprogramowania wykorzystującego metodę elementów skończonych.
Źródło:
Archives of Metallurgy and Materials; 2012, 57, 1; 325-331
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An overview of heat transfer enhancement based upon nanoparticles influenced by induced magnetic field with slip condition via finite element strategy
Autorzy:
Hafeez, Muhammad B.
Krawczuk, Marek
Shahzad, Hasan
Powiązania:
https://bibliotekanauki.pl/articles/2105987.pdf
Data publikacji:
2022
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
magnetohydrodynamic flow
porous medium
nanofluids
heat transfer
thermal performance
convective boundary conditions
FEM
Opis:
The mathematical model of heat generation and dissipation during thermal energy transmission employing nanoparticles in a Newtonian medium is investigated. Dimensionless boundary layer equations with correlations for titanium dioxide, copper oxide, and aluminium oxide are solved by the finite element method. Parameters are varied to analyze their impact on the flow fields. Various numerical experiments are performed consecutively to explore the phenomenon of thermal performance of the combination fluid. A remarkable enhancement in thermal performance is noticed when solid structures are dispersed in the working fluid. The Biot number determines the convective nature of the boundary. When the Biot number is increased, the fluid temperature decreases significantly. Among copper oxide, aluminium oxide, and titanium oxide nanoparticles, copper oxide nanoparticles are found to be the most effective thermal enhancers.
Źródło:
Acta Mechanica et Automatica; 2022, 16, 3; 200--206
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Poprawa parametrów energetycznych i ekologicznych budynku wielorodzinnego w celu spełnienia wymagań WT 2021
Improvement of energy and ecological parameters of multi-family building to comply WT 2021 requirements
Autorzy:
Jura, J.
Powiązania:
https://bibliotekanauki.pl/articles/2065489.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska
Tematy:
warunki techniczne
współczynnik przenikania ciepła
termomodernizacja
pompa ciepła
ogniwa fotowoltaiczne
technical conditions
heat transfer coefficient
thermo-modernization
heat pump
photovoltaic cells
Opis:
Przedstawiono wymagania dla budynków wg warunków technicznych obowiązujących obecnie oraz wchodzących w życie od 1 stycznia 2021 roku. Wykonano optymalizację konstrukcji przegród budowlanych, systemu ogrzewania oraz przygotowania ciepłej wody użytkowej dla budynku wielorodzinnego. W budynku wykorzystane zostały również nowoczesne technologie generujące ciepło oraz energię ze źródeł odnawialnych. Wykonano analizę kosztów realizacji zaproponowanych przedsięwzięć budowlanych dla usprawnień, spełniających wymagania WT 2017 oraz WT 2021, oraz czasu zwrotu poniesionych nakładów finansowych potrzebnych na ich sfinansowanie.
The article presents the requirements for buildings according to the current technical regulations and coming into force as of January 1, 2021. The optimization of the building partitions, the heating system and the preparation of hot water for the multi-family building. Modern building technologies generate heat and energy from renewable sources. The costs of proposed improvements and the time spent to reimburse the financial resources needed to finance them have been analyzed.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2018, 7, 1; 15--22
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A numerical method for viscous flow in a driven cavity with heat and concentration sources placed on its side wall
Autorzy:
Ambethkar, V.
Basumatary, L. R.
Powiązania:
https://bibliotekanauki.pl/articles/122794.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
numerical method
viscous flow
heat source
concentration source
driven square cavity
general algorithm
stability conditions
isotherms
streamlines
geometric center
heat and mass transfer
metoda numeryczna
lepki przepływ
źródło ciepła
warunki stabilności
izotermy
transfer ciepła
transfer masy
Opis:
This paper proposes a method to numerically study viscous incompressible two-dimensional steady flow in a driven square cavity with heat and concentration sources placed on its side wall. The method proposed here is based on streamfunction-vorticity (Ψ-ξ) formulation. We have modified this formulation in such a way that it suits to solve the continuity, x and y-momentum, energy and mass transfer equations which are the governing equations of the problem under investigation in this study. No-slip and slip wall boundary conditions for velocity, temperature and concentration are defined on walls of a driven square cavity. In order to numerically compute the streamfunction Ψ, vorticityfunction ξ , temperature θ, concentration C and pressure P at different low, moderate and high Reynolds numbers, a general algorithm was proposed. The sequence of steps involved in this general algorithm are executed in a computer code, developed and run in a C compiler. We propose that, with the help of this code, one can easily compute the numerical solutions of the flow variables such as velocity, pressure, temperature, concentration, streamfunction, vorticityfunction and thereby depict and analyze streamlines, vortex lines, isotherms and isobars, in the driven square cavity for low, moderate and high Reynolds numbers. We have chosen suitable Prandtl and Schmidt numbers that enables us to define the average Nusselt and Sherwood numbers to study the heat ad mass transfer rates from the left wall of the cavity. The stability criterion of the numerical method used for solving the Poisson, vorticity transportation, energy and mass transfer has been given. Based on this criterion, we ought to choose appropriate time and space steps in numerical computations and thereby, we may obtain the desired accurate numerical solutions. The nature of the steady state solutions of the flow variables along the horizontal and vertical lines through the geometric center of the square cavity has been discussed and analyzed. To check the validity of the computer code used and corresponding numerical solutions of the flow variables obtained from this study, we have to compare these with established steady state solutions existing in the literature and they have to be found in good agreement.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2018, 17, 3; 17-30
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat transfer in road pavement structure and identification of its layers thermal parameters
Wymiana ciepła w konstrukcji nawierzchni drogowej i identyfikacja parametrów materiałowych tworzących jej warstwy
Autorzy:
Aliawdin, P.
Połczyński, J.
Powiązania:
https://bibliotekanauki.pl/articles/395947.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
nawierzchnia drogowa
wymiana ciepła
konstrukcja nawierzchni drogowej
pavement system
heat transfer problem
boundary conditions identification
road pavement structure
Opis:
A heat transfer problem for the road pavement system "layered plate - embankment - soil base" is formulated. There are suggested mathematical models and their realization with the use of finite element analysis and design software program by solving the layered plate on the ground foundation. Transient thermal state for this road structure is defined by discretization of the system described by different material properties. The theoretical results are compared with the experiment data for the real road pavement of Lubuski province road No 297 on the route Zagan-Kozuchow in Poland. Finally, two inverse problems are formulated, to identify respectively the boundary conditions and heat material parameters of road structure by smooth (least squares) and nonsmooth (minimax) optimization. It was shown that the criterion of least squares does not give trust results and only nonsmooth criterion of minimax lead to a trust result of the identification.
W pracy przedstawiono identyfikację parametów materiałowych oraz warunków granicznych ośrodka niejednorodnego, jaki stanowi konstrukcja nawierzchni drogowej. Problem ten rozwiązano poprzez analizę wymiany ciepła dla układu "płyta wielowarstwowa - nasyp - podłoże gruntowe". Na podstawie wieloletnich badań doświadczalnych rozkładu temperatury sformułowane zostały proste i odwrotne zagadnienia nieustalonego przepływu ciepła, zrealizowane przy pomocy metody elementów skończonych. Dla identyfikacji stosowane były metody gładkiej i niegładkiej optymalizacji z kryterium najmniejszych kwadratów oraz kryterium minimaxu. Druga z metod okazała się skuteczną, ponieważ w odróżnieniu od pierwszej możliwe było wyznaczenie optymalnych wartości wszystkich badanych materiałów tworzących warstwy konstrukcji drogowej. Podane przykłady analizy numerycznej porównane zostały z wynikami badań doświadczalnych uzyskanych z poligonów zlokalizowanych na drodze wojewódzkiej nr 296 w miejscowości Kożuchów w Polsce.
Źródło:
Civil and Environmental Engineering Reports; 2010, 5; 63-78
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Współczynnik przenikania ciepła w świetle nowego Rozporządzenia Ministra Transportu, Budownictwa i Gospodarki Morskiej. Badanie współczynnika przenikania ciepła w warunkach in situ. Cz.2 – Badania
Heat transfer coefficient in view of the new Regulation of the Minister of Transport, Construction and Maritime Economy. Study of the heat transfer coefficient in in situ conditions. Part 2 – Study
Autorzy:
Bieranowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/162558.pdf
Data publikacji:
2014
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
współczynnik przenikania ciepła
ISO 9869
definicja
interpretacja
badanie in situ
pomiar
warunki
heat transfer coefficient
definition
interpretation
in situ test
measurement
conditions
Opis:
W drugiej części publikacji przedstawiono współczynnik przenikania ciepła U [W/m2K] w interpretacji fizycznej, zaprezentowano definicję normową podbudowaną ilustracjami, podano wartości tegoż parametru wynikające z uaktualnionego przepisu prawnego i ostatecznie opisano algorytmy (metody wartości średniej) służące do pomiaru współczynnika przenikania ciepła w warunkach in situ w oparciu o nietłumaczoną do tej pory na język polski normy ISO 9869 Thermal insulation – Building elements – In situ measurement of thermal resistance and thermal transmittance [2]
The second part of the paper was devoted to the presentation of the heat transfer coefficient U [W/m2K] in physical interpretation, its standard definition supported by illustrations was presented, values of the parameter arising from the updated legal provision and finally, the algorithms (mean value methods) applied for measuring of heat transfer coefficient in in situ conditions basing on the ISO 9869 Standard Thermal insulation – Building elements – In situ measurement of thermal resistance and thermal transmittance [2], not translated into Polish, were described.
Źródło:
Przegląd Budowlany; 2014, R. 85, nr 3, 3; 25-30
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Economic practicability of the implementation of the mine refrigeration technology for normalization of thermal conditions
Autorzy:
Alabiev, Vadim R.
Dozorov, Alexander V.
Savvateeva, Irina A.
Druzyanova, Varvara P.
Sangadzhiev, Mergen M.
Powiązania:
https://bibliotekanauki.pl/articles/220336.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chłodzenie kopalni
maszyna chłodnicza
warunki termiczne pracy
drilling galleries
heat transfer fluid
mine refrigeration technology
an underground cooling machine
working thermal conditions
economic practicability
Opis:
The purpose of this research is to substantiate a technical solution for improving the working conditions for the thermal factor in the extraction of oil by the thermoshaft method using the mine refrigeration technology. The review of manufacturers and technical characteristics of refrigeration technology in Russia, CIS countries and Western Europe was conducted. It was shown that the use of a water cooling machine in the mine air conditioning system will reduce the air temperature in the oil production gallery to the required values and will allow to abandon the long-term construction of a surface stationary refrigeration station. Normalization of the thermal regime reduces the costs of benefits and compensation for work in harmful labor conditions and improves the quality of service of production wells by operators. The practical significance is that the proposed project for the introduction of air conditioning has a high level of profitability, and its payoff will occur in the second year of operation.
Źródło:
Archives of Mining Sciences; 2020, 65, 2; 271-284
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies