Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "heat emission" wg kryterium: Temat


Wyświetlanie 1-46 z 46
Tytuł:
Emission and trends in reclaiming waste heat in industrial instalations
Autorzy:
Hys, L.
Wiak, T
Powiązania:
https://bibliotekanauki.pl/articles/952453.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
heat emission
waste heat
heat waste reclaim
distributed generation
Opis:
The article presents the analysis of waste heat emission in a typical industrial installation. On the basis of the process monitoring system, periodic analyses of fumes composition, installation process manual and the conducted measurements of the heat fluxes from individual sources emitting heat on the way of natural convection from the devices’ coats and forced convection in the fumes flux were calculated. According to the authors the heat of temperature 140–155 °C and surface power density 860–970 W/m2 emitted by devices’ covers can be reclaimed in ORC techniques, Peltier’s modules and the systems realising Stirling cycle. Part of the waste heat included in fumes, which makes c.a. 76% of the total emission from the installation, should be returned to the process of fuel oxidation, what will reduce the emission by c.a. 18% and the volume of consumed fuel by c.a. 25 m3 CH4/h, according to the presented calculations.
Źródło:
Journal of Ecological Engineering; 2013, 14, 2; 26-30
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Angle of injection impact on the combustion proces in a compression-ignition engine
Autorzy:
Łagowski, P.
Kurczyński, D.
Wcisło, G.
Pracuch, B.
Tomyuk, V.
Powiązania:
https://bibliotekanauki.pl/articles/411209.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Oddział w Lublinie PAN
Tematy:
Perkins AD3 152UR engine
heat emission
Opis:
The article presents the impact of hydrocarbon fuel angle of injection on heat emission characteristics in a compression - ignition AD3.152 engine. The angle of injectionhas a significant impact on the primary engine operating parameters and combustion process indicators, which include the proportion of combustion which occurs according to kinetic and diffusion models, heat emission rate and the combustion process duration. The characteristics describing emission of a relative heat quantity were determined on the basis of an analysis of actual, indicator diagrams averaged over 100 runs, under the assumption that the combustion process ends by the time the exhaust valve opens. During the test, the engine operated according to an external speed characteristic. Tests were carried out for three fuel angles of injection: 13, 17 and 21 crankshaft rotation degrees.
Źródło:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes; 2018, 7, 4; 29-36
2084-5715
Pojawia się w:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie badań modelowych w przybliżonej ocenie strumienia ciepła jawnego z powierzchni zabudowanej
Application of model tests in the assessment of surface sensible heat fluxes
Autorzy:
Klemm, K.
Powiązania:
https://bibliotekanauki.pl/articles/362451.pdf
Data publikacji:
2016
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
badania modelowe
emisja ciepła
zabudowa
laser
model tests
heat emission
building
Opis:
W pracy przedstawiona została propozycja oceny wielkości strumienia ciepła jawnego z powierzchni zabudowanej. Badania prowadzone były w tunelu aerodynamicznym przy przyjętych skalach podobieństwa KL = 100, KU = 2, KTx = 8 i Kt = 50. Turbulencyjny przepływ strumienia powietrza nad wymodelowanym obszarem zabudowy był rejestrowany przy wykorzystaniu wiązki światła laserowego. Określenie współczynnika struktury optycznej C2n pozwoliło ustalić wielkość współczynnika struktury termicznej C2T. Przyjmując profil prędkości wiatru o charakterze logarytmicznym wyznaczono wartość prędkości tarciowej, a w dalszej kolejności funkcji Monina - Obuchowa fT (z/zL). Na podstawie uzyskanych danych oszacowano skalę temperatury Tx i wielkość strumienia ciepła jawnego QH.
The paper presents an assessment method of surface sensible heat fluxes. The study was conducted in wind tunnel with assumed similarity scales: KL = 100, KU = 2, KTx = 8 and Kt = 50. Laser beam was used to record turbulent air flow over modeled built area. Refractive index structure parameter allows determination of the temperature structure parameter. Friction velocity and Monin – Obuchow function were determined assuming logarithmic velocity profile. Obtained data allowed estimation of temperature scale and magnitude of sensible heat fluxes.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2016, T. 8, nr 1, 1; 21-26
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the impact of combustion hydrogen addition on operating properties of self-ignition engine
Ocena wpływu spalania dodatku wodoru na własności eksploatacyjne silnika o zapłonie samoczynnym
Autorzy:
Kruczyński, S.
Ślęzak, M.
Gis, W.
Orliński, P.
Powiązania:
https://bibliotekanauki.pl/articles/1365770.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
IC engines
hydrogen
diesel
heat emission
silniki spalinowe
wodór
olej napędowy
wydzielanie się ciepła
Opis:
The work presents the results of effect of the addition of hydrogen in an amount up to 9% of mass of diesel oil into the intake system of Perkins1104C-E44TA engine. The impact of hydrogen addition on process heat release in the combustion chamber and the concentration of CO, THC, NOX and PM in the exhaust at predetermined engine operating conditions. It was summarised that the analysis of the results does not justify the use of hydrogen as a fuel additive in self-ignition engines.
W pracy przedstawiono wyniki badań wpływu dodatku wodoru w ilości do 9% masy oleju napędowego do układu dolotowego silnika Perkins1104C-E44T. Oceniono wpływ dodatku na proces wydzielania ciepła w komorze spalanie i stężenia CO, THC, NOX i PM w spalinach w ustalonych warunkach pracy silnika. W podsumowaniu stwierdzono iż analiza wyników badań nie uzasadnia stosowania wodoru jako dodatku do paliwa w silnikach o zapłonie samoczynnym.
Źródło:
Eksploatacja i Niezawodność; 2016, 18, 3; 343-347
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat exchange in the system mould - riser - ambient. Part II: Surface heat emission from open riser to ambient
Wymiana ciepła w układzie forma - nadlew - otoczenie. Część II: Współczynnik emisji ciepła z otwartego nadlewu do otoczenia
Autorzy:
Krajewski, P. K.
Gradowski, A.
Krajewski, W. K.
Powiązania:
https://bibliotekanauki.pl/articles/352192.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
castings
risers
surface heat emission
heat balance
solidification modelling
odlewy
nadlew
emisja ciepła
bilans cieplny
modelowanie krzepnięcia
Opis:
The subject of the paper is heat exchange in the system casting - riser - ambient. The examinations were focused on evaluating temperature dependence of the coefficient of heat exchange from open (not shielded) top surface of riser to ambient. The examinations were carried out on the open surface of cast steel riser, of temperatures 1000-1500°C. On the basis of the performed examinations it was stated that heat emission coefficient changes its mean values by about 50% during feeding process of the mild steel casting, i.e. from about 0.28 in liquid state to about 0.42 at temperatures close to solidus. This wide range of surface heat emissivity changes should be taken into account when boundary conditions are formulated in elaborated models of solidification and in designing risering systems.
Przedmiotem artykułu jest wymiana ciepła w systemie odlew - nadlew - otoczenie. Celem badań było wyznaczenie temperaturowej zależności współczynnika wymiany ciepła z odkrytej, nieizolowanej powierzchni nadlewu do otoczenia. Badania wykonano dla odlewu staliwnego z odkrytym nadlewem, dla zakresu temperatury powierzchni nadlewu 1000-1500°C. Na podstawie wykonanych badań stwierdzono, iż współczynnik emisji ciepła z nieizolowanej powierzchni nadlewu do otoczenia zmienia swą wartość w badanym zakresie temperatury o około 50%, tj. od około 0.26 - 0.30 dla metalu w stanie ciekłym do około 0.42 - 0.46 dla metalu w stanie stałym, w pobliżu temperatury solidus. Powyższy szeroki zakres zmian emisyjności powinien być uwzględniany w budowanym modelach symulacji procesu krzepnięcia i projektowania systemów zasilania krzepnących odlewów.
Źródło:
Archives of Metallurgy and Materials; 2013, 58, 4; 1149-1153
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Analysis of Thermal Properties of Selected Rock Materials by Thermovision Methods
Analiza właściwości cieplnych wybranych surowców naturalnych, na podstawie badań wykorzystujących metody termowizyjne
Autorzy:
Stempkowska, A.
Izak, P.
Mastalska-Popławska, J.
Staszewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/319117.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
ciepło właściwe minerałów
emisja ciepła
termiczne właściwości skał
moc cieplna
termowizja
minerals specific heat capacity
heat emission
rocks thermal properties
thermal power
thermovision
Opis:
Heat accumulation means denotes the of a material to collect and store inside a specific amount of thermal energy, which can be then returned for a period time from the material. There are many investigations devoted to finding a method to collect heat when there is an excess and to use it when there is a deficit. The parameter determining whether the returned heat long for a term will have an impact on the room temperature, is the time of emission of stored energy. For the specified amount of stored energy, the emission time cannot be too short (in such a case too much heat in the unit time is returned) or too long (in this case a too small amount of heat in the time unit is returned, for example insufficient for heating rooms). The main aim of this research is to investigate the behavior (during cooling) of natural rock materials. On the basis of research and performed calculations the evaluation of tested materials to serve as the heat accumulator was performed. This analysis would allow them to be applied for the production of components, including precast, working at elevated temperatures, in which the accumulation and transfer of heat is important (eg. housing furnaces and fireplaces).
Akumulacja ciepła oznacza zdolność materiału do gromadzenia i magazynowania w jego wnętrzu określonej porcji energii cieplnej, która następnie może być przez pewien okres czasu przez ten materiał oddawana. Szuka się więc sposobów gromadzenia ciepła wtedy, gdy jest jego nadmiar oraz wykorzystania, gdy występuje deficyt. Parametrem, decydującym o tym czy oddający ciepło materiał w sposób długotrwały będzie oddziaływał na temperaturę pomieszczenia, jest czas oddawania (emisji) zgromadzonej energii. Przy danej ilości zgromadzonej energii, czas jej emisji nie może być zbyt krótki (wtedy w jednostce czasu oddawane są zbyt duże ilości ciepła) ani zbyt długi (wtedy w jednostce czasu oddawane są zbyt małe ilości ciepła, niewystarczające np. do ogrzania pomieszczenia). W niniejszej pracy zrelacjonowano eksperyment polegający na badaniu zachowania się, podczas studzenia, naturalnych surowców mineralnych. Na tej podstawie badań oraz wykonanych obliczeń oceniono jego zdolność do akumulacji cieplnej. Pozwoliłoby to na stosowanie ich do wytwarzania elementów, w tym prefabrykatów, pracujących w podwyższonych temperaturach, gdzie jest istotna akumulacja i oddawanie ciepła (np. obudowy palenisk i komików).
Źródło:
Inżynieria Mineralna; 2018, R. 20, nr 2, 2; 337-344
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozkład temperatur „naskórkowych terenu w Polsce - wstępne spostrzeżenia geologiczne
Distribution of Earths skin temperature in Poland - preliminary, geological views
Autorzy:
Ostaficzuk, S.
Powiązania:
https://bibliotekanauki.pl/articles/395017.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
temperatura naskórkowa Ziemi
EO NASA dane
plamy ciepła
geotermika
emisja ciepła
Earth's skin temperature
EO NASA data
warm patches
geothermics
heat emission
Opis:
Przeprowadzono analizę rozkładu temperatur w przypowierzchniowej strefie Ziemi na podstawie danych satelitarnych NASA (http://earthobservatory.nasa.gov/GlobalMaps/). Bezpośredni wpływ oświetlenia słonecznego, pokryw śniegowych oraz lodów wyeliminowano przez wykorzystanie tylko średnich nocnych temperatur miesięcznych z czerwca, lipca, sierpnia i września z lat 2000 i 2012. Pobierane były obrazy globalne z tego okresu w przedziale EO° do E360° i N-63° do N63°; dla Polski przyjęto lądowy obszar E14° do E25°/N49° do N55° oraz obszar NW Polski od E14° do E18°/ od N51° do N55°. Miesięczne średnie temperatur nocnych były pobierane z całych wymienionych obszarów oraz dla porównania z profili diagonalnych NW-SE i SW-NE. Stwierdzono wyraźne podwyższenia temperatury w obszarach miejskich i przy zbiornikach wód otwartych. Mniej wyraźne, ale nieprzypadkowe odchyłki negatywne temperatur średnich stwierdzono w obszarach spiętrzeń morenowych i w obszarach górskich. Mniejszy wpływ na odchyłki temperatur powierzchni terenu ma zróżnicowanie pokryw roślinnych. Stwierdzona regionalizacja rozkładu anomalii średnich może mieć związek ze zróżnicowaniem intensywności naturalnego strumienia cieplnego Ziemi (por. Szewczyk i Gientka 2009). Badania są dopiero zainicjowane, ale pierwsze wyniki wykazują przydatność tego źródła danych w określaniu: wstępnych parametrów ujęć geotermalnych, temperaturowych anomalii antropogenicznych oraz trendów krótkotrwałych zmian klimatycznych.
The Earth's superficial temperature distribution in Poland was analyzed based on the NASA satellite data (http://earthobservatory.nasa.gov/GlobalMaps/). The direct impact of sunrays, snow cover and ices was eliminated by using only night pictures from the months without snow — June to September 2000 and 2013. Geographically, data images were acquired from images covering the following areas: global EO° to E360°/N —63° to N63°; for Poland E14° to E25°/N49° to N55° and for the NW Poland E14° to E18°/N51 ° to N55°. Average monthly temperature data were collected from the entirety of the mentioned areas and, for the control, from the diagonal profiles NW-SE and SW-NE: Urbanized areas and peripheries of open waters were characterized by higher temperatures then average, while lower than average were temperatures of glacial end moraines and mountain areas. Vegetation cover has a lesser impact on night temperatures on land. The apparent regional distribution of temperature variances may represent some manifestations of variables in the natural heat flow from the deeper subsurface spheres of the Earth (see Szewczyk and Gientka 2009). The presented analyses have only just been initiated, but preliminary results point to the prospective applicability of global temperature data in geothermic studies, land use planning, and delineating of global temperature trends.
Źródło:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN; 2013, 84; 131-135
2080-0819
Pojawia się w:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania parametrów emisji ciepła i dymu wybranych materiałów wykończeniowych metodą SBI
Tests of heat and smoke parameters from selected finishing materials using SBI test method
Autorzy:
Konecki, M.
Kolbrecki, A.
Papis, B.
Powiązania:
https://bibliotekanauki.pl/articles/182769.pdf
Data publikacji:
2009
Wydawca:
Instytut Techniki Budowlanej
Tematy:
metoda SBI
stanowisko badawcze
materiał budowlany
wydzielanie ciepła
wydzielanie dymu
analiza niepewności
niepewność pomiaru
pożar
materiał wykończeniowy
właściwości fizykochemiczne
wyniki badań
single burning item
test stand
building material
heat emission
smoke emission
measurement uncertainty
uncertainty analysis
fire
finishing material
physicochemical properties
test results
Opis:
Przedstawiono wyniki badań emisji ciepła i dymu z wybranych materiałów budowlanych przy zastosowaniu metody SBI. Wykonano analizę niepewności pomiarowych mierzonych wielkości oraz przedyskutowano różnice w wartościach parametrów emisji ciepła i dymu materiałów lignocelulozowych.
The paper presents the heat and smoke results obtained in tests of selected building materials using SBI method. The uncertainty analysis of obtained results was presented. The test results of heat and smoke emission for cellulosic based materials has been shown and discussed.
Źródło:
Prace Instytutu Techniki Budowlanej; 2009, R. 38, nr 3, 3; 47-59
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat balance of the military vehicle
Autorzy:
Brzeżański, M.
Mężyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/133873.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
heat balance
thermal energy storage
emission of heat
thermal image
IR device
bilans cieplny
magazynowanie energii cieplnej
emisja ciepła
obraz termowizyjny
Opis:
In modern combat vehicles there are very often used observation devices with the capability of operating in the infrared. They allow detecting heat emission. It is very important to reduce such situation on the battlefield; therefore generated heat masking or reducing systems are used. The article presents the heat balance of the military vehicle, impact of heat amount on detectability and solutions reducing or changing the thermal image which impedes recognition.
Źródło:
Combustion Engines; 2017, 56, 3; 131-134
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie emisji ciepła i dymu z materiałów budowlanych metodą kalorymetru stożkowego według ISO 5660
Test of heat and smoke emission from selected building materials using cone fire test method ISO 5660
Autorzy:
Kolbrecki, A.
Konecki, M.
Papis, B.
Powiązania:
https://bibliotekanauki.pl/articles/182966.pdf
Data publikacji:
2009
Wydawca:
Instytut Techniki Budowlanej
Tematy:
kalorymetr stożkowy
próbka
spalanie
metodyka badań
wydzielanie ciepła
wydzielanie dymu
materiał budowlany
ISO 5660
materiał wykończeniowy
właściwości fizykochemiczne
wyniki badań
analiza niepewności
niepewność pomiaru
cone calorimeter
test methodology
sample
combustion
heat emission
smoke emission
building material
finishing material
physicochemical properties
test results
measurement uncertainty
uncertainty analysis
Opis:
W artykule podano podstawy metodyki badań z zastosowaniem kalorymetru stożkowego według ISO 5660. Wykonano analizę niepewności pomiarowych szybkości wydzielania ciepła. Przedstawiono i przedyskutowano wyniki badań otrzymane przy spalaniu wybranych materiałów budowlanych.
The paper includes the test methodology for cone calorimeter using according to ISO 5660. The uncertainty analysis of obtained results was presented. The test results for selected buliding materials has been shown and discussed.
Źródło:
Prace Instytutu Techniki Budowlanej; 2009, R. 38, nr 3, 3; 27-46
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of the type of heat sources on carbon dioxide emissions
Autorzy:
Rabczak, S.
Proszak-Miąsik, D.
Powiązania:
https://bibliotekanauki.pl/articles/124035.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
CO2 emission
heat pump
heat source
greenhouse gases
Opis:
A lot of attention is nowadays devoted to the problem of generally defined ecology. It is absolutely essential in case of systems and sources generating heat due to their direct influence on the environment through emitting post-process products to the atmosphere which are, most frequently a result of combustion. Therefore, constant searchers are made to optimize the operation of heat sources and to acquire energy from sources for which the general balance of carbon dioxide emission is zero or close to zero. This work compares the emissions of equivalent CO2 from selected systems with the following heat sources: coal, gas furnace, heat pump, and refers results of the analysis to aspects connected with regulations concerning environmental protection. The systems generating thermal energy in the gas furnaces, coal, biomass, as well as the compression heat pumps with the lower heat source as ambient air or ground were taken under consideration, as well as centralized systems for the production of heat based on the combustion of coal, gas, oil, and biomass. the Emission of carbon dioxide for the installation of cogeneration and absorption heat pump were also calculated. Similarly obtained amount of extra emission necessary for the proper operation maintenance of heating devices via the supplied electricity from external source, the mostly fuel-fired power plants for fuels as previously mentioned. The results of the calculations were presented in tables and graphs.
Źródło:
Journal of Ecological Engineering; 2016, 17, 5; 186-191
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie metodą emisji akustycznej rozciąganych próbek stalowych
Stretching tests of steel samples by the acoustic emission method
Autorzy:
Łapiński, Z.
Łukaszewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/235041.pdf
Data publikacji:
2006
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
emisja akustyczna
obróbka cieplna
acoustic emission
heat treatment
Opis:
W artykule przedstawiono wyniki badań metodą Emisji Akustycznej rozciąganych próbek stalowych poddanych uprzednio obróbkom cieplnym i i chemicznym.
The results of tests carried out by the acoustic emission method against the steel samples after the thermal and chemical treatment are presented in the paper.
Źródło:
Problemy Techniki Uzbrojenia; 2006, R. 35, z. 99; 143-154
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ indukcyjnego systemu grzewczego o zmniejszonej emisji zaburzeń
Inductive heating systems with reduce conducted emission
Autorzy:
Ligmann, K.
Galla, S.
Powiązania:
https://bibliotekanauki.pl/articles/266484.pdf
Data publikacji:
2011
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
indukcyjne urządzenie grzewcze
emisja
inductive heat
conducted emission
Opis:
Przedstawiono wyniki pracy nad indukcyjnym systemem grzewczym, w którym w szczególności uwzględniono problemy minimalizacji zaburzeń elektromagnetycznych wprowadzanych w czasie pracy do sieci zasilającej. W pracy przedstawiono i opisano zastosowany układ indukcyjnego systemu grzejnego oraz przedstawiono uzyskane wyniki badań rozwijanej konstrukcji i zalecenia konstrukcyjne.
The results are presents of work on the induction heating system, which in particular includes the minimization problems of electromagnetic disturbances introduced during work to the mains. The paper presents and describes used the system and presents the results of research and some construction recommendations.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2011, 30; 89-92
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Conception of cylinder pressure based diesel injection control system
Autorzy:
Bieniek, A.
Powiązania:
https://bibliotekanauki.pl/articles/245444.pdf
Data publikacji:
2011
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
diesel injection
cylinder pressure
control system
emission
heat release
Opis:
Control of diesel fuel injection is very important and has influence not only at engine operating conditions but also at emission of toxic gases as NOx, HC, and Particulate Matter (PM) are effect of combustion process. Directly observing of combustion process is very difficult, but implementation to injection control algorithm procedures based on additional sensors as knock sensor, cylinder pressure sensor and observing of rotational speed course could give enough information to optimize control algorithm. In traditional diffusion-burn diesel combustion start of combustion occurs a cetane-number based time delay after the start of the fuel injection. To fulfill of new emission standards is need to observing not only start of combustion but also whole combustion process. In the paper conception of injection control system applied with combustion process observer based on additional sensors. Closed-loop feedback control of cylinder pressure sensor and advanced control algorithm with high-resolution rotational speed sensor offers the potential to improve controllability of combustion process. Advanced control system based on heat release estimated from cylinder pressure and rotational speed fluctuations enabling improving engine exhaust emissions, engine performance and reduced noise emission. Introducing into control system a low cost glow plug integrated cylinder pressure sensor allow to achieve complete injection control system with advanced functions which could be very effective also in aspect of fuel consumption reduction.
Źródło:
Journal of KONES; 2011, 18, 3; 27-35
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pollutant concentrations from deciduous wood fuelled heat station
Autorzy:
Juszczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/185275.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stacja ciepła
spalanie
emisja
drewno
heat station
wood
combustion
emission
Opis:
CO, NO, NO2 and dust concentrations from combustion of deciduous wood (birch, beech, lime-tree) logs and pellets in two heating boilers (15 and 25 KW), situated in a heat station were investigated. Time dependences of pollutant concentrations as well as the impact of temperature in the combustion chamber and oxygen concentration on pollutant concentrations were presented. Pollutant emission indices have been estimated.
Źródło:
Chemical and Process Engineering; 2011, 32, 1; 41-55
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stężenia tlenku węgla i tlenków azotu (NO, NOX) z kotła o mocy 25 kW zasilanego peletami drzewnymi w sposób periodyczny i ciągły
Concentrations of carbon monoxide and nitrogen oxides (NO, NOX) from a 25 kW boiler supplied periodically and continuously with wood pellets
Autorzy:
Juszczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/357176.pdf
Data publikacji:
2013
Wydawca:
Politechnika Śląska
Tematy:
drewno
emisja
spalanie
kocioł
kotłownia
wood
emission
combustion
boiler
heat station
Opis:
The impact of periodic and continuous feeding mode on the carbon monoxide (CO) and nitrogen oxides (NO, NOx) concentration values in the flue gas downstream the boiler was analyzed during firing 4,6 and 8 kg/h of wood pellets in an overfeed- channel furnace. Significant increase of CO concentration during periodic feeding mode in comparison to continuous feeding mode, was observed only in the case of very long stand-by period. In periodic fuel supply with constant air stream, during stand-by period in fuel feeding, the temperature in combustion chamber decreased, however oxygen concentration increased. These factors, that usually influence nitrogen oxide concentration compensated mutually to a big extent. Therefore, the concentration of nitric oxide (NO) and nitrogen oxides (NOx) mainly depended on the stream of nitrogen in the fuel supplied to the furnace, as temperature in the combustion chamber was relatively low (below 700°C). Investigations were performed in the full-scale heat station in conditions similar to these which appeared in reality.
Stężenia tlenku węgla i tlenków azotu (NO, NOX) z kotła o mocy 25 kW zasilanego peletami drzewnymi w sposób periodyczny i ciągły. Badano wpływ periodycznego i ciągłego zasilania peletami drzewnymi kotła z paleniskiem nasuwowym-korytkowym, na stężenia tlenku węgla i tlenków azotu (NO i NOx) w spalinach. Stwierdzono, że stężenie tlenku węgla dla zasilania periodycznego rośnie znacząco w stosunku do zasilania ciągłego dopiero dla bardzo długich przerw w dozowaniu peletów. W czasie dozowania periodycznego paliwa (przy stałym strumieniu powietrza), temperatura w komorze spalania obniżała się a stężenie tlenu rosło. Te czynniki, które wpływały na zmniejszenie i wzrost stężenia tlenków azotu, wzajemnie się kompensowały w dużym stopniu. Stężenia tlenków azotu zależały więc głównie od strumienia azotu dostarczanego do paleniska w paliwie, dlatego że temperatura w komorze spalania była względnie niska (poniżej 700°C). Badania były prowadzone w kotłowni w pełnej skali technicznej, w warunkach zbliżonych do rzeczywistej eksploatacji.
Źródło:
Archiwum Gospodarki Odpadami i Ochrony Środowiska; 2013, 15, 3; 17-24
1733-4381
Pojawia się w:
Archiwum Gospodarki Odpadami i Ochrony Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza energetyczno-ekologiczna wykorzystania pompy ciepła do ogrzewania tunelu foliowego
Power use and ecological analysis for use of heat pump applied to heat a foil tunnel
Autorzy:
Kurpaska, S.
Latała, H.
Powiązania:
https://bibliotekanauki.pl/articles/287516.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
tunel foliowy
pompa ciepła
emisja
substancja szkodliwa
ciepło
foil tunnel
heat pump
emission
harmful wastes
heat
Opis:
W pracy przedstawiono wyniki badań związanych z efektami energetyczno-ekologicznymi wykorzystania pompy ciepła do ogrzewania tunelu foliowego. Pompa grzewcza pracowała w układzie hybrydowym, tzn. jako dolne źródło ciepła wykorzystano energię zmagazynowaną w zbiorniku cieczowym. W zbiorniku zainstalowano wymiennik stanowiący dolne źródło ciepła sprężarkowej pompy grzewczej. Uzyskane wyniki przeliczono na zmiany emisji substancji szkodliwych emitowanych do atmosfery w wyniku spalania tradycyjnego nośnika ciepła.
The paper presents test results pertaining to power use and ecologic effects for use of heat pump applied to heat a foil tunnel. The heat pump was operated in a hybrid system, i.e. the energy stored in a tank with liquid was used as a lower source of heat; the mentioned tank being equipped with a heat exchanger to be utilized as a lower source of heat for compressor type heat pump. The obtained results were calculated into changes of harmful waste substances flowing to the environment as a result of traditional burning of the heating medium.
Źródło:
Inżynieria Rolnicza; 2007, R. 11, nr 6 (94), 6 (94); 121-127
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termodinamicheskaja vozmozhnost povyshenija ehffectivnosti DVC
Thermodynamics possibility of increase of efficiency of combustion engines
Autorzy:
Podznoev, G.
Abdulgazis, Y.
Zharik, T.
Powiązania:
https://bibliotekanauki.pl/articles/78218.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
combustion engine
diesel fuel
exhaust gas
diesel engine
pollutant emission
heat regeneration
Opis:
A thermodynamic analysis of the possibility of catalytic reforming of water emulsified diesel fuel by the heat of the exhaust gases. The results indicate the potential for a significant increase in efficiency of a diesel engine with a substantial improvement in the quality of the kinetics and combustion and a significant reduction of pollutant emissions in the exhaust gases. Calculations confirmed a significant reduction in consumption of primary diesel fuel, while maintaining the amount of useful work
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2013, 15, 5
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Concentrations of carbon monoxide and nitrogen oxides from a 25 kW boiler supplied periodically and continuously with wood pellets
Autorzy:
Juszczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/185416.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pelety
spalanie
emisja
stacja ciepła
coniferous
wood pellets
combustion
emission
heat station
Opis:
The impact of the fuel feeding mode (continuous or periodic with different stand-by/operation time ratios) on carbon monoxide (CO) and nitrogen oxides (NO, NOx) concentration values in the flue gas was analysed for coniferous wood pellet firing. Experiments were performed in a 25 kW water boiler equipped with an over-fed wood pellet furnace located in a full scale heat station simulating real-life conditions. Influence of oxygen concentration and temperature in the combustion chamber on carbon monoxide and nitrogen oxide concentrations was presented in diagrams. Dust and hydrocarbon concentrations were also monitored. It was concluded that the commonly used periodic fuel supply does not necessarily cause a significant increase of carbon monoxide concentration, as compared to the continuous fuel feeding mode. Continuous fuel supply can even induce higher carbon monoxide concentrations when fuel mass stream is not chosen properly. Each time new fuel type is used in a specific furnace, one should perform experiments to determine the adequate settings (stand-by/operation time ratio, fuel mass streams, air stream) to obtain the optimal, lowest possible emission for a certain boiler heat output.
Źródło:
Chemical and Process Engineering; 2014, 35, 2; 163-172
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air Pollution as an Indicator of Local Environmental Safety Based on the Example of the Town of Barlinek
Autorzy:
Świerszcz, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/2154730.pdf
Data publikacji:
2022-09-30
Wydawca:
Wydawnictwo Adam Marszałek
Tematy:
ecological safety
air pollution indicators
air pollution measures
low emission
heat poverty
Opis:
This article aims to present the state of air quality treated as a measure of the state of quality of local environmental safety, based on the research conducted in the town of Barlinek. This information is necessary to identify the areas that require action to improve air quality (to reduce the concentration of pollutants). The main factors that inspired the author to address this issue are, first of all, the continuous high level of air pollution, despite the actions taken to reduce it; secondly, the lack of precise, clear indicators and measures of such deprivation that applies to a major part of the territory of Poland that would take into account the individual national context; thirdly, the need to identify the main factors that determine this phenomenon in the specific context of Poland. Other factors include the need to consider the requirement for Poland as a member state of the EU to participate in reducing air pollution to an appropriate extent; and, finally, the need to develop and implement integrated 10-year National Energy and Climate Plans (NECP) for the years 2021–2030 with a long-term perspective to the year 2050, as well as long-term renovation strategies to improve the accuracy of eliminating air pollution. The research problem focuses on three issues: presenting the current national and European criteria of ecological safety for air pollution, identifying the indicators and measures that enable the determination of air pollution levels, and presenting the local air pollution level based on the selected example. The research problem discussed in the article is empirical. Analytical/synthetic, qualitative and quantitative methods were used to provide a more in-depth analysis of the problem, and conclusions were drawn.
Źródło:
Polish Political Science Yearbook; 2022, 3 (51); 19-38
0208-7375
Pojawia się w:
Polish Political Science Yearbook
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of influence of thermo-cycles on hydrogen cracking of steel
Autorzy:
Skalsky, V.
Rudavskyy, D.
Matvijiv, Y.
Powiązania:
https://bibliotekanauki.pl/articles/328091.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
stal
wodór
emisja akustyczna
obieg ciepła
steel
heat cycling
hydrogen concentration
acoustic emission
Opis:
Influence of thermo-cycles "heating-cooling" on the hydrogen induced cracking of structural steels, which are widely used in the heat-power equipment is investigated in this paper. An acoustic emission method of diagnostics of specimens made of exploited and non-exploited material of steam pipelines is described. Effective diagrams of dependence of number of events on heat cycle number for the all groups of specimens are plotted.
Źródło:
Diagnostyka; 2009, 2(50); 19-22
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of geothermal energy in co-generated heat and power production in Poland : a case study
Autorzy:
Mróz, Tomasz Maciej
Grabowska, Weronika
Powiązania:
https://bibliotekanauki.pl/articles/2073770.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cogenerated heat and power
CHP
organic rankine cycle
ORC
energy performance
CO2 emission
Opis:
The paper presents the results of energy and environmental evaluation of geothermal CHP plant. The variant of CHP plant based on Organic Rankine Cycle (ORC) has been taken into consideration as the most favorable for the geothermal conditions prevailing in Poland. The existing geothermal well located in the city of Konin in Greater Poland (Wielkopolska) voivodship has been chosen as the case study. The conceptual design of CHP plant has been proposed and evaluated from energy and environmental point of view. The non-renewable primary energy consumption has been chosen as energy performance criterion. In the case of environmental performance carbon dioxide emission has been taken as evaluation criterion. The analysis has been performed for different operating conditions and three working fluids. The best energy performance can be spotted for working fluid R123, for which the reduction varies between 15200 and 11900 MWh/a. The working fluid R134a has a worse energy performance, which allows for the reduction of fossil fuels energy consumption in the range of 15000 and 11700 MWh/a. The total reduction of CO2 emission is the highest for working fluid R123: 5300 to 4150 MgCO2/a, the medium one for working fluid R134a: 5200 to 4100 MgCO2/a and the lowest for working fluid R227: 5000 to 4050 MgCO2/a. It has been shown that the construction of geothermal CHP plants based on Organic Rankine Cycle can be reasonable solution in Polish conditions. It is important concerning the need of reduction of fossil fuels primary energy consumption and carbon dioxide emission.
Źródło:
Archives of Environmental Protection; 2021, 47, 3; 82--91
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ własności absorpcyjno-emisyjnych ściany wewnętrznej na charakterystykę cieplną fasady podwójnej
The efect of wall emission-absorption on thermal characteristic of DSF
Autorzy:
Heim, D.
Jabłoński, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/363014.pdf
Data publikacji:
2007
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
fasady podwójne
absorpcja
emisja
magazynowanie ciepła
energooszczędność
emission
double facades systems
absorption
heat accumulation
Opis:
W niniejszej pracy przeanalizowano wpływ emisyjności powierzchni ściany pomidzy użytkową przestrze- nią budynku a przestrzenią podwójnej fasady na cieplne zachowanie się przegrody oraz jej wydajność energetyczną. Dyskretyzacji w przestrzeni dokonano za pomocą Metody Objętości Skończonych, zaś analizy symulacyjne wykonano metodą opartą na sprzężonym modelu wymiany ciepła i masy w budynkach [1]. Otrzymano wartości temperatur ekstremalnych w przestrzeni fasady oraz w pomieszczeniu znajdującym się w bezpośrednim, termicznym kontakcie z fasadą.
The paper presents and discusses the efect of the emission-absorption characteristics of the inner skin in double fasades systems (DSF). The second skin of fasades are design inter alia in order to keep the comfort and healthy indoor climate but the properties of inner elements may play so important role as ventilation or shading. The thermal analysis of DSF have been done using the whole building simulation technique -En- vironmental System Performance (ESP). The results of the air and shows the important differences between light and heavy traditional constructions
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2007, T. 2; 79-82
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pollutant emission from a heat station supplied with agriculture biomass and wood pellet mixture
Autorzy:
Juszczak, M.
Lossy, K.
Powiązania:
https://bibliotekanauki.pl/articles/185505.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pozostałości rolnicze
drewno
spalanie
emisja
stacja ciepła
agricultural residue
wood
combustion
emission
heat station
Opis:
Tests for combustion of hay and sunflower husk pellets mixed with wood pellets were performed in a horizontal-feed as well as under-feed (retort) wood pellet furnace installed in boilers with a nominal heat output of 15 and 20 kW, located in a heat station. During the combustion a slagging phenomenon was observed in the furnaces. In order to lower the temperature in the furnace, fuel feeding rate was reduced with unaltered air stream rate. The higher the proportion of wood pellets in the mixture the lower carbon monoxide concentration. The following results of carbon monoxide concentration (in mg/m3 presented for 10% 02 content in flue gas) for different furnaces and fuel mixtures (proportion in wt%) were obtained: horizontal-feed furnace supplied with hay/wood: 0/100 - 326; 30/70 - 157; 50/50 - 301; 100/0 - 3300; horizontal-feed furnace supplied with sunflower husk/wood: 50/50 - 1062; 67/33 - 1721; 100/0 - 3775; under-feed (retort) furnace supplied with hay/wood: 0/100 - 90; 15/85 - 157; 30/70 - 135; 50/50 - 5179; under-feed furnace supplied with sunflower husk/wood: 67/33 - 2498; 100/0 - 3128. Boiler heat output and heat efficiency was low: 7 to 13 kW and about 55%, respectively, for the boiler with horizontal-feed furnace and 9 to 14 kW and 64%, respectively, for the boiler with under-feed furnace.
Źródło:
Chemical and Process Engineering; 2012, 33, 2; 231-242
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Limiting odour emission from piggery trough application of heat recovery system
Ograniczanie emisji odorów z tuczarni poprzez zastosowanie instalacji do odzysku ciepła
Autorzy:
Rzeźnik, W.
Mielcarek, P.
Rzeźnik, I.
Powiązania:
https://bibliotekanauki.pl/articles/93428.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
odour emission
deep litter
heat pump
cooling manure
odór
emisja
głęboka ściółka
pompa ciepła
schładzanie obornika
Opis:
The aim of the study was to determine the effect of manure cooling by the use of the heat recovery system on odour emission from a deep litter piggery. Annual comparative research was carried out in a twinroom deep litter piggery located in Wielkopolska Voivodeship. The recovered heat was transferred to central heating and domestic hot water systems of a residential building. The study showed that the average odour emission rate from the room, where heat was recovered (0.192±0.083 ouE·s-1·kg m.c.-1) was lower than in the room without heat recovering (0.273±0.138 ouE·s-1·kg m.c.-1) (p<0.05). The difference was 27%. It was also found that there was statistically significant strong correlation (r =0.86) between the amount of the recovered heat and the percentage odour emission reduction (p <0.05). This relationship was described by the logarithmic regression line y=12.5ln(x)-21.5 (r2=0.74).
Celem pracy było określenie wpływu schładzania obornika, w kojcu z głęboką ściółką na emisję odorów z tuczarni, poprzez zastosowanie instalacji do odzysku ciepła. Roczne badania porównawcze przeprowadzono w dwukomorowej tuczarni na głębokiej ściółce znajdującej się w województwie wielkopolskim. Budynek wyposażony był w instalację do odzysku ciepła z głębokiej ściółki. Dolnym źródłem był obornik znajdujący się w kojcu, natomiast górnym były instalacje centralnego ogrzewania i ciepłej wody użytkowej budynku mieszkalnego. W pracy wykazano, że średni wskaźnik emisji odorów z komory, gdzie odzyskiwano ciepło (0,192±0,083 ouE·s-1·kgm.c.-1) był mniejszy, niż w komorze bez odzysku ciepła (0,273±0,138 ouE·s-1·kgm.c.-1) (p<0,05). Różnica ta wynosiła 27%. Stwierdzono również, że między ilością pobranego ciepła, a procentową redukcją emisji odorów istnieje statystycznie istotna silna zależność, r=0,86 (p<0,05). Opisano ją dobrze dopasowaną do danych empirycznych (r2=0,74) logarytmiczną linią regresji o równaniu y=12,5ln(x) – 21,5.
Źródło:
Agricultural Engineering; 2016, 20, 1; 167-176
2083-1587
Pojawia się w:
Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of heat recovery from deep litter piggery on greenhouse gases and ammonia emissions
Wpływ odzysku ciepła z głębokiej ściółki na emisję gazów cieplarnianych i amoniaku
Autorzy:
Rzeźnik, W.
Rzeźnik, I.
Powiązania:
https://bibliotekanauki.pl/articles/337029.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
greenhouse gas emission
ammonia emission
deep litter piggery
heat pump
cooling manure
emisja gazów cieplarnianych
emisja amoniaku
tuczarnia
głęboka ściółka
pompa ciepła
schładzanie obornika
Opis:
The aim of this study was to determine the effect of cooling deep litter in a pen for pigs by using the heat recovery system on greenhouse gases and ammonia emission from piggery and residential building. The research was carried out in farm located in Wielkopolska Voivodeship, where the heat recovery system from deep litter was installed. Fermenting manure stored on the floor of piggery was the heat source and central heating, domestic hot water system in residential building were the heat sink. Cooling manure in deep litter pen for pigs resulted in reducing greenhouse gas emissions from piggery by about: 11,424 kg•yr-1 (12,1%) for CH4, 662 kg•yr-1 for N2O (16,2%) and 3,532 kg for NH3 (15,7%). The use of heat re-covered from the deep litter to supply central heating and domestic hot water system in residential building reduced carbon dioxide emissions by 7,377 kg•yr-1 (35%). Weighted average reduction of greenhouse gas emissions from the researched farm, taking into account the mass of each gas was 13.7%.
Celem pracy było określenie wpływu schładzania obornika w kojcu z głęboką ściółką przez zastosowanie instalacji do odzysku ciepła z głębokiej ściółki na emisję gazów cieplarnianych i amoniaku z tuczarni oraz budynku mieszkalnego. Badania prowadzono na terenie gospodarstwa rolnego, zlokalizowanego w województwie wielkopolskim, w którym zamontowano instalację do odzysku ciepła. Głównym źródłem były instalacje centralnego ogrzewania i ciepłej wody użytkowej budynku mieszkalnego. Schładzanie obornika w kojcu z głęboką ściółką przez zastosowanie instalacji do odzysku ciepła spowodowało ograniczenie emisji gazów cieplarnianych z tuczarni: CH4 o 11424 kg•rok-1 (12,1%) i N2O o 662 kg•rok-1 (16,2%) oraz amoniaku (NH3) o 3532 kg rocznie (15,7%). Wykorzystanie ciepła pobranego z głębokiej ściółki do zasilania instalacji c.o. i c.w.u. budynku mieszkalnego ograniczyło emisję dwutlenku węgla o 7377 kg•rok-1, czyli o 35%. Średnia redukcja emisji gazów cieplarnianych z badanego gospodarstwa, uwzględniając ich udział ilościowy, wynosiła 13,7%.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2015, 60, 2; 72-75
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operational determinants of gaseous air pollutants emissions from coal-fired district heating sources
Eksploatacyjne uwarunkowania emisji zanieczyszczeń gazowych z węglowych źródeł ciepłowniczych
Autorzy:
Zwierzchowski, Ryszard
Różycka-Wrońska, Ewelina
Powiązania:
https://bibliotekanauki.pl/articles/2073776.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
district heating
gaseous air pollutant emission
emission indicators
unstable conditions
heat only boilers
ciepłownictwo
emisja gazowych zanieczyszczeń powietrza
wskaźniki emisji
niestabilne warunki
kotły grzewcze
Opis:
This study describes the correlation between emission of gaseous pollutants to the atmosphere and the combustion parameters of a coal-fired 25 MW heating capacity water boiler with mechanical grate (boiler type WR-25) in unstable working conditions: start-up, shutdown and loads below the technical minimum. Whereas measurements were made for a specific type and size of coal-fired water boiler with mechanical grate, the measurements and calculations are applicable to WR boilers with a different heating power as well as OR type steam boilers, which have a practically identical design. In sum, there are more than 1,000 coal-fired water and steam boilers of these types in Poland. In addition, the analysis reported in this paper highlights the important role played by boilers operating in unstable conditions in terms of emission of gaseous pollutants to the atmosphere. The conclusions are relevant for other boilers fi red with gas, oil or biomass operating under conditions such as start-up, shutdown and loads below the technical minimum. This article fi lls a gap in air protection engineering practice and the literature with regard to indicators and emission standards, drawing on measurements of pollutant concentrations in the exhaust gases from unstable WR boiler working conditions. The measurements can be used to assess the emission of pollutants to the atmosphere in such boiler working conditions and their impact on air quality. The analyses presented were based on the authors’ own measurements in WR-25 boiler technical installations using portable gas analyser GASMET DX-4000, which uses the FT-IR measurement method for compounds such as SO2, NOx, HCl, HF, NH3, CH4, and CO. Concentrations of CO, NOx and SO2 in exhaust gases were determined with multiple regression with the STATISTICA statistical software and with linear regression complemented by the “smart” package in the MATLAB environment. The study provides computational models to identify pollutant concentrations in the exhaust gases in any working conditions of WR-25 boilers.
Prezentowana praca badawcza opisuje korelację między emisją gazowych zanieczyszczeń powietrza do atmosfery, a parametrami spalania dla wodnego kotła rusztowego opalanego węglem typu WR-25, o mocy cieplnej 25 MW w niestabilnych warunkach pracy, takich jak: rozruch, odstawianie z ruchu i praca przy obciążenia poniżej minimum technicznego. Przedstawione analizy opierały się na własnych pomiarach autorów wykonanych dla kotłów rusztowych typu WR zasilających w ciepło miejskie systemy ciepłownicze oraz na wynikach z symulacji komputerowych wykorzystujących uzyskane dane pomiarowe. Autorzy prezentują, wskaźniki emisji zanieczyszczeń gazowych do atmosfery, w oparciu o pomiary tych emisji w niestabilnych warunkach pracy kotła typu WR, a których to wskaźników aktualnie brakuje zarówno w literaturze jak i praktyce inżynierii ochrony atmosfery. Wskaźniki te pozwolą na rzeczywiste oszacowanie wielkości emisji gazowych zanieczyszczeń do atmosfery w takich niestabilnych warunkach pracy kotła, jak również ich wpływ na jakość powietrza w otoczeniu. Prezentowana praca dostarcza modele obliczeniowe do identyfikacji obciążenia emisyjnego zanieczyszczeniami gazowymi do atmosfery w jakichkolwiek, a przede wszystkim w niestabilnych warunkach pracy kotłów typu WR-25.
Źródło:
Archives of Environmental Protection; 2021, 47, 3; 108--119
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Equivalent Carbon Dioxide Emission in Useful Energy Generation in the Heat-Generating Plant – Application of the Carbon Footprint Methodology
Autorzy:
Chłopek, Zdzisław
Lasocki, Jakub
Melka, Krzysztof
Szczepański, Krystian
Powiązania:
https://bibliotekanauki.pl/articles/1839094.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
carbon dioxide
CO2
greenhouse gases
GHG
emission
energy generation
heat plant
coal
carbon footprint
CF
Opis:
The energy sector worldwide is a significant source of air pollutant emission. In Poland, the vast majority of heat and electricity is generated in coal-fired heat and power plants. There is a common belief that high greenhouse gas emissions from the energy sector in Poland are mainly due to the technological processes involving the conversion of energy by burning fossil fuels. However, coal mining also causes a high environmental burden. This paper aimed to determine the carbon footprint of a typical hard coal-fired heating plant in Poland, taking into account mining of hard coal, its transport to the heating plant and useful energy generation in the heating plant. The investigation carried out allowed comparing the process steps and determining which of them is the dominant source of the greenhouse gas emissions. The obtained results show that hard coal mining and hard coal transport account for almost 65% and 5% of total equivalent carbon dioxide emission, respectively. Energy transformations in the heating plant account for 30% of total equivalent carbon dioxide emission, where approx. 29% is due to hard coal burning and 1% due to electricity consumption. The relative shares of carbon dioxide, methane and nitrous oxide in total equivalent carbon dioxide emission account for approx. 91%, 4% and 5%, respectively.
Źródło:
Journal of Ecological Engineering; 2021, 22, 2; 144-154
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Correlation between air flow rate and pollutant concentrations during two-stage oak log combustion in a 25 KW residential boiler
Autorzy:
Juszczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/184902.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wood combustion
pollutant emission
heating boiler
heat station
spalanie drewna
emisja zanieczyszczeń
kocioł grzewczy
stacja ciepła
Opis:
It can be expected that there is a considerable correlation between combustion air flow rate and the concentrations of carbon monoxide, hydrocarbons and nitrogen oxide in the flue gas. The influence of temperature and oxygen concentration in the combustion zone on the concentrations of carbon monoxide, hydrocarbons and nitrogen oxide in the flue gas, for high and low combustion air flow, was analysed. Oxygen concentration for which the concentration of carbon monoxide is the lowest was determined, as well as the mutual relation between carbon monoxide and nitrogen oxide concentration.
Źródło:
Chemical and Process Engineering; 2016, 37, 3; 419-428
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sposoby obniżania emisji gazowych w bezściołowym systemie utrzymania zwierząt
Different ways for reduction of gaseous emission in slated floor systems of animal housing
Autorzy:
Myczko, R.
Powiązania:
https://bibliotekanauki.pl/articles/239288.pdf
Data publikacji:
2006
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
gnojowica
emisja gazów
amoniak
komora fermentacyjna
wymiennik ciepła
metodyka
slurry
gas emission
ammonium
fermentation chamber
heat exchanger
Opis:
Przedstawiono założenia i metodykę badań dotyczących oceny sposobów obniżania emisji wybranych gazów: NH3, CH4, N2O oraz CO2 powstających w trakcie przechowywania gnojowicy, poprzez stosowanie dodatków chemicznych, mikrobiologicznych, oraz przykrywanie i ochładzanie powierzchni gnojowicy. Zamieszczono opis przygotowanych stanowisk badawczych. Opracowano szczegółową metodykę badań z wykorzystaniem spektroskopu fotoakustycznego Multi-gas Monitora do badania stężenia gazów oraz sposób wyznaczania emisji gazów z komór fermentacyjnych.
Designed experiment concerns the assessment of different ways for reduction NH3, CH4, N2O and CO2 emissions, appearing during slurry storage. The assumptions and methodology of preliminary research was shown. The description of research stand, and laboratory equipment was shown. The laboratory stand was equipped with two kinds of fermentation chambers. The methodology of research based on measurements of gas concentration with use of photoacoustic Multi-gas Monitor. The way of determination of gas emission from fermentation chambers was described.
Źródło:
Problemy Inżynierii Rolniczej; 2006, R. 14, nr 1, 1; 135-142
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szacowanie emisji tlenków azotu (NOx) na podstawie danych eksploatacyjnych rzeczywistego obiektu przemysłowego
Estimation of nitrogen oxides NOx emission based on data from real industry plant
Autorzy:
Gramacki, A.
Gramacki, J.
Powiązania:
https://bibliotekanauki.pl/articles/154296.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
NOx
Elektrociepłownia Zielona Góra
regresja liniowa
szacowanie
NOx emission
combined heat and power plant
CHP
linear regression
Opis:
W pracy podjęto próbę szacowania emisji tlenków azotu (NOx,) na podstawie danych eksploatacyjnych zbieranych podczas normalnej pracy Elektrociepłowni w Zielonej Górze. Pomimo że zanieczyszczenia te monitorowane są z użyciem specjalistycznych czujników, to wydaje się, że dodatkowa ich kontrola może być bardzo pożądana. Zwłaszcza, że ilość emitowanych zanieczyszczeń (w tym NOx) jest ściśle limitowana i kontrolowana. Wspomniane szacowanie wykonano wykorzystując technikę statystyczną zwaną regresją liniową.
In the paper there is analysed the possibility of estimating nitrogen oxides NOx emissions based on the data taken from an industry plant (gas-based combined heat and power (CHP) plant in Zielona Góra, Poland). Even though the emission of NOx is monitored on-line by dedicated sensors installed on the plant, we believe that some additional monitoring would be desirable. This is especially important because emission of different kind of air-pollutants (including NOx) is strictly limited and monitored. The above mentioned estimation is performed by the statistical technique known as linear regression. In Section 2 the gas-based combined heat and power plant in Zielona Góra is briefly described. A simplified chart of the plant is shown in Fig. 1. The list of measurement points taken from the DCS system (distributed control system) of the greatest influence on the NOx emission is also given. In Section 3 there is shown the way how the raw data should be prepared, especially in the context of removing unwanted disturbances as well as the points which were selected for the final regression analysis. The results obtained are presented in Section 4. The best regression solution (row 3 in Table 3) is shown in Fig. 4. The accuracy is quite satisfactory and we believe that it is sufficient for the purpose of additional monitoring the main NOx sensors installed on the plant.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 7, 7; 461-463
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The ecological impact of using photothermal and photovoltaic installations for DHW preparation
Ekologiczny wpływ zastosowania instalacji footermicznej i fotowoltaicznej do przygotowania ciepłej wody użytkowej
Autorzy:
Olczak, Piotr
Olek, Małgorzata
Kryzia, Dominik
Powiązania:
https://bibliotekanauki.pl/articles/282886.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
photovoltaic panel
reduction of CO2 emission
evacuated tube collector with heat pipe
panel fotowoltaiczny
redukcja emisji CO2
próżniowy kolektor rurowy typu heat pipe
Opis:
A domestic hot water (DHW) system has been modernized in a multi-family house, located in the southeastern part of Poland, inhabited by 105 people. The existing heating system (2 gas boilers) was extended by a solar system consisting of 32 evacuated tube collectors with a heat pipe (the absorber area: 38.72 m2). On the basis of the system performance data, the ecological effect of the modernization, expressed in avoided CO2 emission, was estimated. The use of the solar thermal system allows CO2 emissions to be reduced up to 4.4 Mg annually. When analyzing the environmental effects of the application of the solar system, the production cycle of the most material-consuming components, namely: DHW storage tank and solar collectors, was taken into account. To further reduce CO2 emission, a photovoltaic installation (PV), supplying electric power to the pump-control system of the solar thermal system has been proposed. In the Matlab computing environment, based on the solar installation measurement data and the data of the total radiation intensity measurement, the area of photovoltaic panels and battery capacity has been optimized. It has been shown that the photovoltaic panel of approx. 1.8 m2 and 12 V battery capacity of approx. 21 Ah gives the greatest ecological effects in the form of the lowest CO2 emission. If a photovoltaic system was added it could reduce emissions by up to an additional 160 kg per year. The above calculations take also emissions resulting from the production of PV panels and batteries into account.
W budynku wielorodzinnym położonym w południowo-wschodniej części Polski, zamieszkałym przez 105 osób, zmodernizowano system przygotowania ciepłej wody użytkowej. Istniejący system grzewczy (2 kotły gazowe) został rozbudowany o układ kolektorów słonecznych składający się z 32 próżniowych kolektorów rurowych (powierzchnia absorbera wynosi 38,72 m2). Na podstawie danych o wydajności systemu oszacowano ekologiczny efekt modernizacji, wyrażony jako uniknięta emisja CO2. Zastosowanie systemu kolektorów słonecznych pozwala zmniejszyć emisję CO2 do 4,4 Mg rocznie. Analizując skutki środowiskowe zastosowania instalacji kolektorów słonecznych, wzięto pod uwagę cykl produkcyjny najbardziej materiałochłonnych komponentów instalacji, a mianowicie zasobnika ciepłej wody użytkowej i kolektorów słonecznych. Aby jeszcze bardziej ograniczyć emisję CO2, zaproponowano instalację fotowoltaiczną, dostarczającą energię elektryczną do napędu pompy obiegowej instalacji kolektorów słonecznych. W środowisku obliczeniowym Matlab, na podstawie danych pomiarowych z instalacji kolektorów słonecznych i danych pomiarowych całkowitego natężenia promieniowania, zoptymalizowano powierzchnię paneli fotowoltaicznych i pojemność akumulatorów. Wykazano, że układ paneli fotowoltaicznych o powierzchni ok. 1,8 m2 oraz akumulatorów 12 V o pojemności ok. 21 Ah zapewnia największy efekt ekologiczny w postaci najniższej emisji CO2. Dodanie paneli fotowoltaicznych może zmniejszyć roczną emisję CO2 nawet o dodatkowe 160 kg. Powyższe obliczenia uwzględniają również emisje wynikające z tytułu produkcji paneli fotowoltaicznych i akumulatorów.
Źródło:
Polityka Energetyczna; 2020, 23, 1; 65-74
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usefulness assessment of automatic air flow control system with oxygen sensor in a 20 kW boiler with periodic wood pellet supply
Autorzy:
Juszczak, M.
Cichy, W.
Palaszynska, K.
Powiązania:
https://bibliotekanauki.pl/articles/52809.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Drewna
Tematy:
usefulness assessment
automatic system
air flow control
oxygen sensor
heating boiler
wood pellet
combustion
pollutant emission
heat station
Źródło:
Drewno. Prace Naukowe. Doniesienia. Komunikaty; 2016, 59, 198
1644-3985
Pojawia się w:
Drewno. Prace Naukowe. Doniesienia. Komunikaty
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Napravlenija elektroobespiecenia i ekologiceskoj bezopacnosti promyszlennych gornodobyvajuscich regionov putem sozdanija teploenergeticeskich kompleksov
Ecological safety of mining regions through creation of power‐heating complexes
Autorzy:
Yefremov, I. A.
Podkopaev, S. V.
Moroz, O. K.
Powiązania:
https://bibliotekanauki.pl/articles/409763.pdf
Data publikacji:
2014
Wydawca:
STE GROUP
Tematy:
energy complex
cogeneration
emission of pollutants
electricity
heat
kompleks energetyczny
kogeneracja
wyrzut substancji zanieczyszczonych
energia elektryczna
energia cieplna
Opis:
There was presented a method of use of alterantive source of energy, namely coal mine methane, the use of which as a fuel for power and heating generation is a main direction in coal mines. By this means some ecological problems of the region are solved. Highly efficient power and heating technologies are implemented and energy complexes are established.
Pokazano sposoby efektywnego wykorzystania nietradycyjnego źródła energii – metanu kopalnianego, którego wykorzystanie w kopalniach węgla kamiennego jest podstawowym kierunkiem dywersyfikacji przedsiębiorstw górniczych w zakresie przerobu pozyskanego metanu w energię elektryczną i cieplną. Tym sposobem rozwiązane zostaną problemy ekologiczne regionu, wdrożenie wysokoefektywnych technologii ciepłowniczych i stworzenie na ich podstawie kopalnianych kompleksów energetycznych.
Źródło:
Management Systems in Production Engineering; 2014, 2 (14); 81-85
2299-0461
Pojawia się w:
Management Systems in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Natural gas saving and emissions decrease in public health care sector – a case study
Ograniczenie zużycia gazu ziemnego i redukcja emisji w sektorze zdrowia publicznego – studium przypadku
Autorzy:
Mierka, Otto
Variny, Miroslav
Skalíková, Ingrida
Sámel, Peter
Kizek, Ján
Súth, Róbert
Nagy, Karol
Powiązania:
https://bibliotekanauki.pl/articles/396176.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
public building
health care sector
natural gas
emission
heat loss
budynek użyteczności publicznej
gaz ziemny
emisja
straty ciepła
Opis:
A study on natural gas saving and emissions decrease in the public health care sector is presented. The analyzed hospital complex belongs to the largest ones in Slovakia and uses both hot water and water steam for heating purposes. Visual steam system inspection revealed serious inefficiencies, including steam venting, missing pipelines insulation and obsolete steam sources with dysfunctional blow-down system. Defined experiment with stepwise steam appliances shutdown enabled quantification of excess natural gas consumption due to these inefficiencies. Measures proposed for the solution of this state are inexpensive, with a short payback period. The expected natural gas savings amount up to 3200 MWh/year, which represents roughly 50% of the total natural gas consumption in the hospital complex.
Niniejszy artykuł prezentuje studium przypadku na temat ograniczenia zużycia gazu ziemnego i emisji w sektorze zdrowia publicznego. Analizowany kompleks szpitalny należy do największych na Słowacji i używa do ogrzewania zarówno ciepłej wody użytkowej, jak i pary wodnej. Kompleks ten będzie w najbliższych latach poddany renowacji, włącznie z instalacją dystrybucji mediów. Analiza obecnego systemu i wynikające z niej zaproponowane sposoby na zaoszczędzenie energii oferują redukcję kosztów powiązanych z przyszłą inwestycją. Wizualna ocena systemu dystrybucji pary wodnej ujawniła poważne wady tego systemu, w tym w odpowietrzaniu systemu, uszkodzonej bądź brakującej izolacji rur, przestarzałych bojlerach parowych z niedziałającym systemem usuwania zanieczyszczeń. Eksperyment ze stopniowym wyłączaniem urządzeń parowych umożliwił ilościowe określenie nadmiaru zużycia gazu ziemnego spowodowanego wspomnianymi niedostatkami. Metodologia takiego eksperymentu jest uniwersalna i łatwa w zastosowaniu w jakimkolwiek innym budynku użyteczności publicznej gdzie podobny system pary wodnej jest w użyciu. Zaproponowane rozwiązania dla poprawy takiego stanu są niedrogie i z krótkim czasem zwrotu inwestycji. Zastosowanie nowej izolacji rur, naprawa odwadniaczy oraz naprawa zaworów redukcyjno-regulacyjnych do odpowietrzania pary w odpowietrznikach są przedmiotem rozważań. Oczekiwana redukcja zużycia gazu ziemnego wynosi do 3200 MWh/rok, co stanowi około 50% rocznego zapotrzebowania tego gazu w kompleksie szpitalnym. Ocena środowiskowa zaproponowanych zmian pozwala oczekiwać redukcji emisji dwutlenku węgla na poziomie 644 ton rocznie oraz tlenków azotu na poziomie 0.75 ton rocznie.
Źródło:
Civil and Environmental Engineering Reports; 2019, 29, 1; 119-127
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ograniczanie emisji zanieczyszczeń gazowych z tuczarni poprzez zastosowanie instalacji do odzysku ciepła
Limiting emission of gas pollution from the fattening house through application of heat recovery installation
Autorzy:
Rzeźnik, W.
Powiązania:
https://bibliotekanauki.pl/articles/288663.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
emisja
zanieczyszczenia gazowe
głęboka ściółka
pompa ciepła
schładzanie
obornik
emission
gas pollution
deep bedding
heat pump
cooling manure
Opis:
Celem pracy było określenie wpływu schładzania obornika w kojcu z głęboką ściółką, poprzez zastosowanie instalacji do odzysku ciepła, na emisję zanieczyszczeń gazowych (NH3, N2O oraz CH4) z tuczarni. Badania porównawcze przeprowadzono w budynku dla trzody chlewnej utrzymywanej na głębokiej ściółce, wyposażonym w instalację do odzysku ciepła, w okresie jednego roku. Górnym źródłem były instalacje c.o. (centralne ogrzewanie) i c.w.u. (ciepła woda użytkowa) budynku mieszkalnego. W pracy wykazano, że między ilością pobranego ciepła a procentową emisją zanieczyszczeń gazowych (NH3, N2O, CH4) istnieje korelacja (p<0,05). Zależności te opisano logarytmicznymi krzywymi regresji: y = 10,8ln(x) - 26,2 (R2=0,83) dla amoniaku, y = 11,5ln(x) - 28,8 (R2=0,9) dla podtlenku azotu oraz y = 6,9ln(x) - 13,4 (R2=0,7) dla metanu. Schładzanie obornika w kojcu z głęboką ściółką poprzez zastosowanie instalacji do odzysku ciepła zmniejsza emisję gazów szkodliwych średnio o 15,7% dla NH3, o 16,2% dla N2O oraz o 12,1% dla CH4.
The objective of the paper was estimation of the impact of cooling manure in a pigpen with deep bedding through the use of the heat recovery installation on emission of gas pollution (NH3, N2O andCH4) from the fattening house. The research was carried out in the building for pigs maintained in deep bedding equipped with the heat recovery installation within one year. Central heating and utility hot water installations of a residential building constituted the upper source. The paper presents that between the amount of the collected heat and percentage emission of gas pollutions (NH3, N2O, CH4) there is a correlation (p<0.05). These relations were expressed with logarythmic regression curves: y = 10.8ln(x) - 2.2 (R2=0.83) for ammonia, y = 11.5ln(x) – 28.8 (R2=0.9) for nitrous oxide and y = 6.9ln(x) – 13.4 (R2=0.7) for methane. Cooling manure in a pigpen with deep bedding through the use of the heat recovery installation reduced emission of harmful gases at the average by 15.7% for NH3, and 16.2% for N2O and by 12.1% for CH4.
Źródło:
Inżynieria Rolnicza; 2013, R. 17, nr 3, t. 2, 3, t. 2; 331-339
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Replacement of emission heating sources with heat and electricity from CHP stations. The idea of ecological economic system solution
Autorzy:
Tokarski, Stanisław
Turek, Marian
Janas, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/325512.pdf
Data publikacji:
2019
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
low emission
heating sources
heat sources
efficiency of use
program
źródła niskiej emisji
źródła ogrzewania
źródła ciepła
efektywność użytkowania
Opis:
The elimination of low-emission sources harmful to human health, mainly domestic boilers, has recently grown into a nation-wide problem in Poland. Emissions of harmful substances from power plants are many times lower than from domestic coal furnaces and are subject to strict regulatory regimes. Hence, companies of the professional and thermal power industry can play an important part in the process of liquidation of low emissions by offering to replace the combustion of coal in home furnaces with the use of it for the production of electricity and system heat in electrical cogeneration, which can then be used for home heating purposes. In addition, it is essential for the professional power industry to maintain a constant daily load of power units, so that the loss of efficiency in regulatory work, increased failure frequency or the need for frequent commissioning does not negatively affect the economy of production. Therefore, the selection of the part of the dispersed heat market that can be replaced with system heat and the use of electricity for heating purposes, while contributing to the elimination of low emissions and improving the economy of new energy units by increase their work in the night low demand periods, must be carried out properly.
Źródło:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska; 2019, 135; 207-221
1641-3466
Pojawia się w:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of low-emissivity coating on heat transfer through the double-glazing windows
Wpływ powłok niskoemisyjnych na przenikanie ciepła przez okna z szybami podwójnymi
Autorzy:
Basok, B.
Davydenko, B.
Zhelykh, V.
Goncharuk, S.
Kugel, L.
Powiązania:
https://bibliotekanauki.pl/articles/362607.pdf
Data publikacji:
2016
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
heat transfer
double-glazed window
emission factor
low-emissivity coating
heat flux
ordinary glass
przenikanie ciepła
okna z szybami podwójnymi
współczynnik emisyjności
powłoki niskoemisyjne
strumień ciepła
szkło zwykłe
Opis:
A numerical study has been conducted to investigate the effect of low-emissivity coatings on the intensity of heat transfer through the double-glassed windows. The results of calculation of heat transfer characteristics through double glassed windows with low-e coating is compared with similar calculation results obtained for the windows with ordinary glass. Availability of low-emission coating leads to a significant increase in heat resistance of the glass. Thus, the replacement one of the glasses of double-glazed windows to a low emissivity glass allows significantly increase the heat resistance of the glazing unit.
Przeprowadzono badania numeryczne w celu określenia wpływu powłok niskoemisyjnych na intensywność przenikania ciepła przez okna z szybami podwójnymi. Wyniki obliczeń dotyczące własności okna podwójnie szklonego z powłoką niskoemisyjną na przenikanie ciepła porównano z wynikami obliczeń dla okien ze zwykłym szkleniem. Zastosowanie powłoki niskoemisyjnej prowadzi do znacznego wzrostu oporu cieplnego szkła. Zatem, wymiana jednej szyby w oknie podwójnie szklonym na szybę z powłoką niskoemisyjną znacząco zwiększa opór cieplny zestawu szybowego.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2016, T. 8, nr 4, 4; 5-8
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ energetyki jądrowej na środowisko
The Impact of Nuclear Energy on Environment
Autorzy:
Rzymkowski, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/214458.pdf
Data publikacji:
2019
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
emisje radioaktywne
tryt
ciepło odpadowe
zanieczyszczenie środowiska
unieszkodliwianie odpadów jądrowych
radioactive emission
trytium
weste heat
environment contamination
nuclear weste disposal
Opis:
W opracowaniu przedstawiono zalecenia dotyczące ochrony środowiska przy projektowaniu i budowie zakładów przemysłu jądrowego oraz zasady unieszkodliwiania odpadów promieniotwórczych.
Indications for environment protection rules in nuclear Energy plants planning and construction, including nuclear waste management are discussed.
Źródło:
Postępy Techniki Jądrowej; 2019, 2; 24-29
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pompy ciepła dla ogrzewania i chłodzenia w aspekcie obniżenia emisji ditlenku węgla
Heat pumps for heating and cooling in terms of reducing carbon dioxine emissions
Autorzy:
Szczechowiak, Edward
Powiązania:
https://bibliotekanauki.pl/articles/2160676.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
pompa ciepła
ogrzewanie
chłodzenie
efektywność
współczynnik SCOP
SCOP
źródło ciepła dolne
źródło ciepła górne
energia odnawialna
emisja dwutlenku węgla
heat pump
heating
cooling
efficiency
seasonal coefficient of performance
lower heat source
upper heat source
renowable energy
carbon dioxide emission
Opis:
Dyrektywy Unii Europejskiej oraz przepisy krajowe wyraźnie wskazują na rozwój budownictwa niemal zeroenergetycznego i o niskiej emisji ditlenku węgla. Artykuł zawiera informacje o tym, jak można zrealizować ten cel poprzez zastosowanie pomp ciepła i to zarówno dla potrzeb ogrzewania, jak i chłodzenia. Omówiono pompy ciepła stosowane w budownictwie, wykorzystujące energię niskopotencjalną: powietrze zewnętrzne, grunt, wodę, ścieki i inne ciepło odpadowe do konwersji na ciepło o potencjale użytkowym: do ogrzewania, podgrzewania ciepłej wody, ale również do chłodzenia pomieszczeń. Podano przykłady rozwiązań dla różnej wielkości budynków i pokazano korzyści wynikające z zastosowania pomp ciepła w aspekcie energetyczno-ekologicznym. Pompy ciepła bardzo dobrze wpisują się w tendencje przyszłościowe i pozwalają na znaczne obniżenie śladu węglowego budynków.
European Union directives and national regulations clearly indicate the development of nearly zero-energy and low-carbon construction. The article provides information on how to achieve this goal by using heat pumps for both heating and cooling. Discussed heat pumps used I construction, using low-potential energy: outdoor air, soil, water, sewage and other waste heat for conversion into heat with a useful potential for heating, hot water, but also for cooling rooms. Examples of solutions for different sizes of buildings are given and the benefits of using heat pumps in terms of energy and ecology are shown. Heat pumps fit very well into the trends of the future and allow for a significant reduction in the carbon footprint of buildings.
Źródło:
Przegląd Budowlany; 2022, 93, 7-8; 160--166
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation on fire potential of ventilation ducts
Autorzy:
Jha, Ankit
Amar, Vinod
Tukkaraja, Purushotham
Powiązania:
https://bibliotekanauki.pl/articles/1839004.pdf
Data publikacji:
2019
Wydawca:
Główny Instytut Górnictwa
Tematy:
auxiliary ventilation
heat release rate
emission factor
differential scanning calorimetry
thermogravimetric analysis
wentylacja pomocnicza
szybkość wydzielania ciepła
współczynnik emisji
różnicowa kalorymetria skaningowa
analiza termograwimetryczna
Opis:
Fires in underground mines can create dangerous conditions for personnel and cause severe damage to property. Because of the confined nature of the underground environment, these effects can escalate rapidly. In underground mines, air ducts/bags are used for ventilating narrow blind headings; these consist of combustible materials that have not been investigated thoroughly in terms of their fire potential and gas emissions. The primary objective of this study is to investigate the fire potential and emission factors for these ducts. A preliminary investigation was performed using differential scanning calorimetry and thermogravimetric analysis. These tests provide crucial information for duct samples including the melting point which is used for designing a novel experimental setup for combustion analysis. This setup was used to perform a combustion experiment at 350 °C, so that all specimens can achieve complete combustion. Furthermore, the heat release rate and emission factors were calculated; it was observed that heat release rate for all the specimens was identical because of similar oxygen consumption during the experiment. Sample B has the lowest emission factor among the four samples (A, B, C, D) tested in this study.
Źródło:
Journal of Sustainable Mining; 2019, 18, 4; 270-276
2300-1364
2300-3960
Pojawia się w:
Journal of Sustainable Mining
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza emisji zanieczyszczeń w wyniku wytwarzania energii cieplnej
Analysis of Emission of Pollution Resulting from Thermal Energy Production
Autorzy:
Noch, T.
Mikołajczewska, W.
Wesołowska, A.
Friedberg, A.
Powiązania:
https://bibliotekanauki.pl/articles/1813745.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
energetyka cieplna
środowisko
spalanie
emisja zanieczyszczeń
olej opałowy
kotłownia
moc
pompa ciepła
OZE
ochrona środowiska
thermal power engineering
environment
emission of pollution
heating oil
boiler
power
heat pump
renewable energy
environment protection
Opis:
W opracowaniu przedmiotem badań jest wytwarzanie energii cieplnej. W wyniku tego zjawiska następuje emisja zanieczyszczeń do atmosfery. Wielkość emisji uzależniona jest od rodzaju i ilości spalanego paliwa. W pracy przedstawiono parametry techniczno-technologiczne urządzeń energetyki cieplnej wykorzystywane w procesie badawczym. W obiekcie eksploatowane są dwa kotły Paromat-Simplex z palnikami Weishaupt L5T D oraz jeden kocioł Paromat ER ND z palnikiem Weishaupt L1Z-B. W pracy dokonano obliczeń wielkości i parametrów emisji. Przeprowadzono badania i obliczenia stężeń emitowanych zanieczyszczeń dla kotłowni olejowej wodno-parowej, eksploatowanej przez obiekt zlokalizowany w Gdańsku Stogach. Badania dotyczą również wykorzystania źródeł energii odnawialnej. W wyniku przeprowadzonych badań porównawczych z zastosowaniem kotła Pilewang Gizex – PM stwierdzono, że oddziaływanie spalania słomy na stan czystości powietrza atmosferycznego jest mniej negatywne niż spalania węgla. Bilans emisji dwutlenku węgla podczas spalania biomasy jest zerowy, gdyż wytworzona jego ilość jest równoważna ilości CO2 pobranej przez roślinę podczas jej wzrostu. Analizą objęto również współpracę kotłowni z zespołem pomp ciepła. System hybrydowy uwzględnia różną moc zainstalowaną w pompach ciepła w granicach Qpc = 13,5-67,5 kW. Moc szczytowa kotłów jest równa Qhybr. = 262,5 kW. Zastosowanie pomp ciepła zmniejszy emisję dwutlenku węgla, odpowiednio dla QPC = 67,5 kW o ∆BCO2 = 33 Mg/a oraz dla QPC = 13,5 kW o ∆BCO2 = 6,6 Mg/a. Z uwagi na to, że badany obiekt zlokalizowany jest na terenie Nadmorskiego Parku Krajobrazowego, wskazane jest możliwie największe ograniczenie emisji zanieczyszczeń z kotłowni (dwutlenku węgla, tlenków siarki, tlenków azotu). Wykorzystanie odnawialnych źródeł energii przez lokalną energetykę cieplną jest korzystne dla ochrony środowiska.
The research is related to thermal energy production and related air pollutions. As a result of this process, emission of pollution to the atmosphere occurs. The effect of pollution depends on the sort and amount of combusted fuel. Technical and technological parameters of thermal energy installations, which have been used in the research process, have been presented. In the building there are two Paromat-Simplex boilers with Weishaupt L5T D burners. In addition to this, a boiler Paromat ER ND with Weishaupt L1Z-B burner is installed. The boilers characteristics are discussed. The influence of thermal energy sources on the environment has been taken into account. Calculations of the volume and parameters of emission have been conducted. The research also concerns the use of renewable energy. As a result of the comparative research with the application of Pilewang Gizex – PM boiler it was found that the influence of straw combustion on the quality of air is less negative than coal combustion. Carbon dioxide emission of biomass combustion is neglected because its amount equals the amount of CO2 absorbed by a plant during its growth. The analysis includes also the hybrid system of a boiler with a set of heat pumps in the power range Qpc = 13,5-67,5 kW. Maximum power of boilers is Qhybr. = 262,5 kW. The application of heat pumps reduces carbon dioxide emission: for QPC = 67,5 kW reduction is ∆BCO2 = 33 Mg/a and for QPC = 13,5 kW it correspond to ∆BCO2 = 6,6 Mg/a. Due to the fact that the object being the subject of the research is located in the Coastal Landscape Park (pol. Nadmorski Park Krajobrazowy) it is advisable to significantly reduce emission of pollution from boilers (carbon dioxide, sulfur oxides, nitrogen oxides). The application of renewable sources of energy by local thermal power engineering is favorable for the protection of the environment.
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 2; 1181-1198
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New way of producing useful energy from biomass in countries decommissioning coal-fired power plants
Nowy sposób wytwarzania energii z biomasy w krajach likwidujących elektrownie węglowe
Autorzy:
Manowska, Anna
Nowrot, Andrzej
Pielot, Joachim
Powiązania:
https://bibliotekanauki.pl/articles/1841456.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
biomass
thermoelectric generator
micro combined heat and power unit
primary energy consumption
emission reduction and renewable energy source
biomasa
generator termoelektryczny
mikro-CHPU
moduł Peltiera
zużycie energii pierwotnej
redukcja emisji i odnawialne źródło energii
Opis:
This paper describes a new way of processing biomass using micro-CHPU devices (Micro Combined Heat and Power Unit). The micro- -CHPU device is a new idea that allows to convert chemical energy in biomass into electricity for charging batteries in small electric vehicles and into useful heat for households. To make the device readily available and inexpensive, commercial Peltier modules were used, in which their operation was inversed to create the Seebeck effect. !e presented research results show that the commercial Peltier module works very well as a thermoelectric generator. The proposed devices may turn out to be very useful in the times of the revolution that has begun on the energy market in most developing countries. Nowadays, many of these countries are intensively beginning to phase out energetics based on fossil fuels. A very popular and effective method of using biomass is mixing it with coal (in the proportion of 10% to 90%) and burning it in a coal-fired power plant or CHP plant. After closing these power plants, biomass will no longer be burned there. !en, the unused biomass could be burned in micro-CHPU devices. This will prevent biomass waste in agriculture.
W artykule opisano nowy sposób przetwarzania biomasy przy użyciu urządzeń mikro-CHPU (Micro Combined Heat and Power Unit). Urządzenie mikro-CHPU to nowy pomysł, który pozwala na zamianę energii chemicznej zawartej w biomasie na energię elektryczną do ładowania akumulatorów w małych pojazdach elektrycznych oraz w ciepło użytkowe dla gospodarstw domowych. Do budowy zastosowano komercyjne moduły Peltiera, w których działanie ich zostało odwrócone w celu uzyskania efektu Seebecka. Z przedstawionych wyników badań wynika, że komercyjny moduł Peltiera bardzo dobrze sprawdza się jako generator termoelektryczny. Proponowane urządzenia może okazać się bardzo przydatne w dobie rewolucji, która rozpoczęła się na rynku energii w większości krajów rozwijających się. Obecnie wiele z tych krajów intensywnie zaczyna odchodzić od energetyki opartej na paliwach kopalnych. Bardzo popularną i efektywną metodą wykorzystania biomasy jest mieszanie jej z węglem (w proporcji od 10% do 90%) i spalanie w elektrowni węglowej lub elektrociepłowni. Po zamknięciu tych elektrowni niewykorzystana biomasa mogłaby zostać spalona w urządzeniach mikro-CHPU.
Źródło:
Inżynieria Mineralna; 2020, 2, 2; 221-230
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe wyzwania wynikające z pakietu klimatyczno-energetycznego dla przemysłu materiałów budowlanych i ceramicznych
New challenges for ceramic and building material industry resulting from climate and energy package
Autorzy:
Duda, J.
Powiązania:
https://bibliotekanauki.pl/articles/392270.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
pakiet klimatyczno-energetyczny
emisja CO2
oszczędność energii
przemysł materiałów budowlanych
przemysł ceramiczny
zużycie energii
wykorzystanie ciepła odpadowego
climate and energy package
CO2 emission
energy conservation
building materials industry
ceramic industry
energy consumption
waste heat utilization
Opis:
Wysoka energochłonność przemysłu materiałów budowlanych i ceramicznych, wynikająca głównie z wysokotemperaturowych procesów wypalania, powoduje, że praktycznie większość działań innowacyjnych ukierunkowana jest na ograniczenie energochłonności i szkodliwego oddziaływania tych procesów na środowisko. Działalność ta jest zgodna z głównym celem klimatycznym Unii Europejskiej, tj. walką z globalnym ociepleniem, zawartym m.in. w pakiecie klimatycznym 3 x 20. Zgodnie z założeniami Komisji Europejskiej opublikowanymi w 2013 r. w Zielonej księdze, zakłada się zmianę obowiązującego do 2020 r. pakietu 3 x 20. W nowej propozycji dotyczącej polityki klimatyczno-energetycznej do 2030 r., Komisja Europejska ogranicza pakiet do dwóch celów, tj. redukcji gazów cieplarnianych o 40% oraz do 27% udziału odnawialnych źródeł energii w końcowym wytworzeniu energii. Założone ok. 40% ograniczenie emisji gazów cieplarnianych wymaga od przemysłu, który ze względu na proces technologiczny charakteryzuje się wysokimi emisjami CO2, poszukiwania nowych technik wytwarzania, które pozwolą zrealizować te cele. W artykule przedstawiono obecny stan realizacji pakietu 3 x 20 oraz możliwości (rezerwy techniczne i technologiczne) wypełnienia nowych obowiązujących po 2020 r. celów polityki klimatycznej.
High energy consumption of ceramic and building material industry resulting mainly from high-temperature burning processes causes that virtually most innovative actions are aimed at the reduction of energy consumption and harmful environmental impact of these processes. This activity corresponds to main European Union climate goal, which is the fight against global warming presented in Package 3 x 20. According to EC assumptions published in 2013 in Green Book, the „20–20–20” package in force to 2020 will be changed. In the new proposal on climate and energy policy to year 2030, European Commission limits package to two goals, i.e. reduction of greenhouse gases by 40% and increase of RES share in final energy consumption to 27%. Set 40% reduction of greenhouse gas emission requires from industries, which due to the technological process have high emission levels of CO2, to search for new production techniques that would allow to meet these goals. This paper presents current status of implementation of main directions of „20–20–20” and possibilities (technical and technological reserves) of satisfying new goals of climate policy in force from 2020.
Źródło:
Prace Instytutu Ceramiki i Materiałów Budowlanych; 2014, R. 7, nr 17, 17; 7-20
1899-3230
Pojawia się w:
Prace Instytutu Ceramiki i Materiałów Budowlanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ głównych komponentów w budynkach na obniżenie emisji ditlenku węgla
The influence of the main components in buildings to the reduction of carbon dioxide emissions
Autorzy:
Szczechowiak, Edward
Powiązania:
https://bibliotekanauki.pl/articles/2160668.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
budynek efektywny energetycznie
efektywność energetyczna
pompa ciepła
energia odnawialna
zużycie energii
emisja ditlenku węgla
przegroda budowlana
przepływ powietrza
źródło energii
energy-efficient building
heat pump
renewable energy
energy consumption
carbon dioxide emission
building partition
air flow
energy source
Opis:
Dyrektywy Unii Europejskiej oraz przepisy krajowe wyraźnie wskazują na rozwój budownictwa niemal zeroenergetycznego i o niskiej emisji ditlenku węgla. Artykuł zawiera informacje o tym, jakie komponenty budynków na to wpływają i jak to osiągnąć. Energia w budynku jest zużywana w czasie jego wznoszenia - tzw. energia wbudowana i w czasie długoletniej eksploatacji. Na parametry energetyczne i ekologiczne wpływają głównie podstawowe komponenty: obudowa budynku i jej właściwości termiczne, szczelność, efektywne techniczne wyposażenie oraz źródła energii i sposób konwersji energii. Wszystkie te komponenty mają wpływ na wskaźnik nieodnawialnej energii pierwotnej i wskaźnik emisji ditlenku węgla. Pokazano przykładowe rozwiązania techniczne zapewniające te niskie parametry. Proponowany kierunek działania jest niezbędny dla przyszłości, aby spełnić wymagania niskiej emisji CO2 oraz wzrostu wykorzystania energii odnawialnej w budownictwie.
European Union directives and national regulations clearly indicate the development of nearly zero-energy and low-carbon construction. The article provides information on what building components affect this and how to achieve it. The energy in the building is consumed during its erection - the so called embodied energy and long-term operational energy. The energy and ecological parameters are mainly influenced by the basic components: the building envelope and its thermal properties and tightness, efficient building services as well as energy sources and the method of energy conversion. All these components have an impact on the non-renewable primary energy index and the carbon dioxine emission factor. Examples of technical solutions ensuring these low parameters are shown. The proposed direction of action is necessary for the future to meet the requirements of low carbon dioxide emissions and the increase in the use of renewable energy in construction.
Źródło:
Przegląd Budowlany; 2022, 93, 7-8; 151--159
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ paliwa zanieczyszczonego chlorem na trwałość elementów kontroli emisji NOX w silniku o zapłonie samoczynnym
The influence of chlorine-contaminated fuel on NOx emission control elements in compression engine
Autorzy:
Faber, J.
Sala, R.
Krasowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/316194.pdf
Data publikacji:
2018
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
paliwo silnikowe
zanieczyszczenia paliwa
chlor
silnik o zapłonie samoczynnym
awarie silników
emisja tlenków azotu
ograniczenie emisji NOx
skład chemiczny osadów
wymiennik ciepła
EGR
motor fuel
fuel contamination
chlorine
self-ignition engine
engine failure
nitrogen oxides emission
NOx emissions reduction
chemical composition of sediments
heat exchanger
Opis:
W artykule podjęto temat oceny wpływu paliwa, celowo zanieczyszczonego chlorem, na elementy kontroli emisji tlenków azotu NOx w silniku z zapłonem samoczynnym. Jakość stosowanego paliwa ma kluczowe znaczenie dla bezawaryjnej pracy silnika. Do zanieczyszczenia paliwa może dojść głównie na etapie transportu lub przechowywania. Główną uwagę zwrócono na wymiennik ciepła (chłodnicę spalin) EGR, służący recyrkulacji spalin, będąc jednym ze sposobów ograniczenia emisji szkodliwych tlenków azotu. Badania prowadzono w warunkach laboratoryjnych (testy stanowiskowe) w cyklach badawczych składających się z czterech faz. Zastosowano paliwo celowo zanieczyszczone chlorem. Czas trwania badania wyniósł 250 godzin i został przerwany momencie wystąpienia awarii silnika i pojawienia się osadów na wymienniku ciepła EGR. W artykule przedstawiono wyniki badań składu chemicznego osadów, zastosowane metody analizy chemicznej oraz zidentyfikowano źródła i przyczynę pojawienia się osadów.
In paper the impact of intentionally chlorine-contaminated fuel on nitrogen oxides emission control elements in compression engine was described. The quality of fuel used is of key importance for the failure-free operation of the engine. Fuel contamination can occur mainly at the transport or storage stage. The main attention was paid to the EGR heat exchanger, which is used for exhaust gases recirculation, being one of the ways to reduce the emission of harmful NOx. The tests were conducted under laboratory conditions (research engine stand tests) in cycles consisting of four phases. The fuel used was intentionally contaminated with chlorine. The test was interrupted after 250 hours at the engine failure and deposits appearance at the EGR heat exchanger. Test results of chemical composition of deposits, analytical methods used and sources and the cause of deposits appearance were described in present paper.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2018, 19, 6; 414-420, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-46 z 46

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies