Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "flow volume" wg kryterium: Temat


Tytuł:
Calculating study of the turbine at last stage flow field in the small volume flow condition
Autorzy:
Jiang, T.
Jin, J.
Wang, Z.
Cao, L.
Li, B.
Powiązania:
https://bibliotekanauki.pl/articles/258680.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
turbine
small volume flow
flow model
backflow
Opis:
Based on basic equation and boundary layer theory of pneumodynamics, the thesis conducts numerical modeling and theoretical analysis on the last stage of turbine characteristics at a small volume flow by using FLUENT, gives an emphasized analysis on the position of first occurrence of backflow and its expansion direction and comes up with flow structure of the turbine flow field at last stage in the small volume flow condition. In connection with specific experiments, it puts forward the flow model of backflow occurring in the last stage field and the solution to the model. The flow field at last stage for a 100MW turbine in the small volume flow condition that is calculated by using the model is basically in conformity to the actual result.
Źródło:
Polish Maritime Research; 2017, S 3; 23-27
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości badań spirometrycznych - wymagania, automatyzacja, praktyka
Quality of spirometry – requirements, automation, practice
Autorzy:
Radliński, J.
Tomalak, W.
Czajkowska-Malinowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/152381.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
spirometria
zapewnienie jakości QA
krzywa przepływ-objętość
zalecenia
spirometry
quality assurance (QA)
flow-volume curve
recommendations
Opis:
W pracy omówiono podstawy wykonywania badania spirometrycznego ze uwzględnieniem procedury pomiaru krzywej przepływ – objętość oraz kryteriów jakościowych oceny spirometrii na podstawie zaleceń standaryzacyjnych. Dokonano analizy jakości pomiaru krzywej przepływ objętość w trzech grupach: u dzieci, u osób w podeszłym wieku oraz uzyskanych w trakcie Światowego Dnia Spirometrii. Podkreślono rolę personelu wykonującego badania oraz sformułowano kilka postulatów dotyczących realizacji sprzętowo – programowych systemów spirometrycznych.
The authors present description of the spirometry focusing on forced flow volume loop measurements and corresponding requirements according to ERS/ATS 2005 [2,3] and PTChP [4] 2006 statements. The introduction to actually applied solutions in supporting automatic assessment of quality assurance (QA)criteria is also presented. The quality analysis of spirometric measurements was performed for three different groups: children younger than 10 years, the group of elderly people and the spirometry obtained during the World Spirometry Day. All the three groups expressed different quality problems: the main problem in children group was too restrictive value of the demanded time of forced expiration (especially regarding significant correlation between the age and the forced expiratory time) – only 23.9% children fulfilled this re-quirements, in the group of elderly people lack of plateau on the expiratory end was the mostly registered error – 60,2%. In the spirometries obtained during the World Spirometry Day the significant number of non-repetitive measurements and the small number of properly performed measurements (only 28%) was the most interesting aspect. The authors concluded that competence and qualifications of the laboratory staff played the most important role in ensuring the quality of spirometry. However, some demands could be addressed to manufacturers of spirometry equipment.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 3, 3; 250-253
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inteligentny przetwornik strumienia objętościowego
Smart volume flow rate transmitter
Autorzy:
Bartyś, M.
Powiązania:
https://bibliotekanauki.pl/articles/277663.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
przetwornik strumienia objętościowego
przepływomierz indukcyjny
inteligentny przetwornik pomiarowy
przemysłowe sieci komunikacyjne
flow volume transmitter
inductive flow meter
smart transmitter
Fieldbus system
Opis:
W artykule zaprezentowano konstrukcję inteligentnego przetwornika do pomiaru strumienia objętościowego płynów. Przetwornik jest przeznaczony zwłaszcza do współpracy z indukcyjnymi, impulsowymi czujnikami przepływu. Przedstawiono podstawowe właściwości metrologiczne generacyjnych czujników indukcyjnych. Wskazano na główne wielkości fizyczne wpływające na niepewność pomiaru. Sprecyzowano wnioski dotyczące możliwości zmniejszenia niepewności pomiaru. Przedstawiono charakterystykę techniczną inteligentnego przetwornika pomiarowego oraz podano przykładowe wyniki badań eksperymentalnych pomiarów strumienia objętościowego.
The smart flow volume transmitter has been presented in this paper. Transmitter has been designed particularly for the use with the inductive volume flow sensors. However, it can be applied also with the variety of other flow volume sensors. The main metrological properties of some class of inductive fluid flow sensors as well as main influencing physical values have been described. The concluding remarks regarding possibilities of the improvement of measurement uncertainty have been formulated. The technical parameters of the smart flow meter have been briefly described. Exemplary experimental results achieved have been shown.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 11; 74-78
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Granice możliwości pomiarowej strumienia objętości w stanowiskach wzorcowych dużych przepływów wody
Limits of the flow rate measurement capability for test rigs of large water flow
Autorzy:
Strzelczyk, P.
Gosk, W.
Powiązania:
https://bibliotekanauki.pl/articles/153035.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stanowiska wzorcowe strumienia objętości
test rigs of volume flow rate
Opis:
W artykule określono czynniki wpływające na możliwość pomiarową strumienia objętości w stanowiskach wzorcowych dużych przepływów wody. W oparciu o przeprowadzoną analizę niepewności oszacowano wpływy tych czynników na niepewność wyznaczania strumienia objętości i przedstawiono uwarunkowania ograniczające możliwości zmniejszenia tych wpływów. Zwrócono szczególną uwagę na błędy w synchronizacji urządzenia przerzutowego. Zaproponowano nowy sposób wprowadzania tych błędów do analizy i nowe rozwiązanie techniczne wielostrumieniowego urządzenia przerzutowego umożliwiające ich zmniejszenie. Przeprowadzona, dla dwóch klas stanowisk o rozpoznanych charakterystykach metrologicznych, analiza zależności między górną granicą zakresu pomiarowego strumienia objętości i niepewnością jego wyznaczenia wskazała na determinujący tę granicę charakter czynnika związanego z błędami w synchronizacji urządzenia przerzutowego.
This paper specifies the factors influencing the flow rate measurement capability for test rigs of large flow. In Sections 3.1 and 3.2 there is presented the analysis of the uncertainty of measuring the flow rate. The influence of particular factors, especially systematic and random errors of diverter synchronization, on the combined standard uncertainty of the flow rate measurement is estimated in Section 3.3 . A new way of taking into account the synchronization errors in the uncertainty analysis is proposed as a function (5). A new way of developing the diverter construction is also presented (Figs. 1 and 2).The analysis of the relationship between the upper limit of the flow rate measuring range and the flow rate measurement uncertainty for two different test rigs is given in Section 5. It con-firmed that the diverter synchronization errors have decisive influence on the measuring range upper limit if the value the flow rate measurement uncertainty is low.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 11, 11; 1298-1301
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar objętości przepływu wody i masy substancji w niej zawartej i jego niepewność na przykładzie stawów rybnych
Measurement of water flow and mass of substances contained therein and its uncertainty based on fishponds example
Autorzy:
Kaca, E.
Powiązania:
https://bibliotekanauki.pl/articles/338204.pdf
Data publikacji:
2013
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
masa przepływu
masowe natężenie przepływu
metody obliczeń
niepewność pomiaru
objętościowe natężenie przepływu
objętość przepływu
flow mass
flow volume
mass flow intensity
methods of calculation
uncertainty of measurement
volumetric flow intensity
Opis:
Przedstawiono metody obliczania objętości przepływającej wody i masy substancji w niej zawartej na podstawie pomiarów objętościowego natężenia przepływu i wyników laboratoryjnych analiz stężeń. Zaproponowano wykonywanie tych obliczeń metodą prostokątów i - szczególnie wygodną, chociaż mniej dokładną - metodą trapezów. Błąd obliczeń tymi metodami jest wprost proporcjonalny do kwadratu okresu próbkowania. Dokładność obliczeń można poprawić, postępując zgodnie z zaproponowanym algorytmem. Zwrócono uwagę na konieczność charakteryzowania wyników obliczeń ich niepewnością, czyli przedziałem wartości, w jakim - z określonym prawdopodobieństwem, np. 95% - znajduje się wartość dokładna. W przypadku pomiarów objętości wody lub masy substancji w niej zawartych na podstawie co najmniej 15 pomiarów cząstkowych (pomiar objętościowego natężenia przepływu, a w przypadku obliczeń masy - dodatkowo stężenia substancji w wodzie) podstawą obliczeń niepewności mogą być odpowiednio: systematyczne niepewności standardowe pomiaru objętościowego natężenia przepływu i dodatkowo- systematyczne niepewności standardowe oznaczeń stężenia substancji w wodzie. W przypadku obliczeń objętości wody lub masy zawartej w niej substancji na podstawie mniejszej liczby pomiarów cząstkowych, podstawą obliczeń niepewności powinny być nie tylko systematyczne, lecz również przypadkowe niepewności standardowe pomiaru objętościowego natężenia przepływu i analiz stężeń substancji w wodzie. Stężenie substancji w wodzie i niepewność wyniku jego pomiaru powinny być określone przez chemiczne laboratoria akredytowane, które oprócz całkowitej niepewności wyniku analizy, powinny podawać jej składowe - niepewność przypadkową i systematyczną. W pracy podano przykłady obliczeń, w których wykorzystano pomiary prowadzone na jednym ze stawów w kompleksie Stawów Raszyńskich w Zakładzie Doświadczalnym Instytutu Technologiczno-Przyrodniczego.
The paper presents methods of calculating the volume of flowing water and mass of substances it contains based on measurements of water flow and laboratory analyses of concentrations. These calculations are proposed to be made with the method of rectangles and with especially convenient though less precise method of trapeziums. Error of calculations with these methods is proportional to the square of the sampling period. The accuracy may be improved by following the proposed algorithm. The need was underlined of characterising the results of calculations by their uncertainty i.e. by the range of values within which, at a certain probability e.g. 95%, falls the exact value. In case of measurements of water volume or mass of substances it contains based on at least 15 partial meas urements (measurement of volumetric flow and, for mass calculations, also the concentration of a substance in water) calculations of uncertainty may be based on systematic standard uncertainty of volumetric flow and systematic standard uncertainty of concentration measurements, respectively. When the number of partial measurements is smaller, than the uncertainty should be based not Orly on systematic but also on random standard uncertainties of volumetric flow measurements and analyses of concentrations. Concentrations of a substance in water and uncertainty of its measurement should be determined by accredited chemical laboratories, which, apart from the total uncertainty of analytical result should also give its components - random and systematic uncertainty. The paper gives examples of calculations which used measurements made in one of ponds in the complex Stawy Raszyńskie of the Experimental Farm, Institute of Technology and Life Sciences.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2013, 13, 1; 31-57
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wear processes of hydraulic plunger and barrel assemblies connected with the time of their work
Autorzy:
Ułanowicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/246273.pdf
Data publikacji:
2014
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
fluid power transmission
pump delivery
volume flow rate
hydraulic precision pair
avionic technology
Opis:
The article discusses the wear processes of hydraulic plunger assemblies connected with the time of their work and the impact exerted by these processes on the value of parameters of a hydraulic plunger pump. It describes working conditions and loading of a hydraulic plunger assembly. The paper presents also the results of empirical analyses of the wear process of the connection of the plunger base with the working surface of the swivel disk, which is related to time and conditions of its work. It discusses the impact of the loading value and sliding speed on the character and intensity of the wear of the connection between the plunger base and the working surface of a swivel disk. Furthermore, it presents a general characteristic and mechanism responsible for the wear of the hydraulic plunger assembly through oxidation. The article also analyses the impact of the hardness of materials used for producing the hydraulic plunger assembly on the intensity of its wear. Another issue is the dependence of the coefficient of friction in the hydraulic plunger assembly on the contact pressure at different sliding speeds. Finally, the paper discusses the impact of wearing of the cooperating plunger base and the working surface of the swivel disk on the initial parameters of the hydraulic pump at a given working pressure and its volumetric efficiency.
Źródło:
Journal of KONES; 2014, 21, 4; 515-524
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of dynamic properties attributable to hydraulic lines onto operation of avionic
Autorzy:
Ułanowicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/247057.pdf
Data publikacji:
2011
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
fluid power transmission
pump delivery
volume flow rate
hydrostatic (forcing) pressure
compressibility effect
viscous friction effect
Opis:
The present paper is dedicated to discuss how dynamic parameters of a hydraulic line intended to transfer hydraulic power from a source of hydraulic power (a hydraulic pump) to an actuating device (a hydraulic motor) can affect operation of an avionic hydraulic drive. Avionic hydraulic drives are operated with fast-varying waveforms of flow intensities and pressures. It is why analysis of most hydraulic drive systems must take account of compressibility of working fluid and elasticity of hydraulic lines. It leads to a wave model for propagation of energy variation down a hydraulic line (a pipe). The paper deals with flow of a compressible liquid via a hydraulic line with flexible walls. Theoretical deliberations were successfully verified by experimental research studies that were carried out on a dedicated test bench, therefore the presented amplitude vs. frequency characteristic curves of the hydraulic line could be obtained from both theoretical considerations and experimental research studied. The experimental research studies were carried out for hydraulic line terminated with a fixed flow restrictor alone and a flow restrictor combined with a hydraulic accumulator as well as for a hydraulic line supplied from a source of constant pressure and terminated with a valve with adjustable flow together with a hydraulic accumulator. The theoretical calculations for the amplitude vs. frequency characteristic curve are based on a model for a hydraulic line with its resistance depending on frequency.
Źródło:
Journal of KONES; 2011, 18, 4; 535-542
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of dynamic properties of hydraulic lines for fluid power transmission
Autorzy:
Ułanowicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/247615.pdf
Data publikacji:
2010
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
fluid power transmission
delivery of a pump
volume flow rate
hydrostatic (forcing) pressure
compressibility effect
viscous friction effect
Opis:
This paper presents the results of a hydraulic line dynamic properties analysis taking into account inertia of the fluid flowing in rigid and flexible lines, the compressibility effect for this fluid and the viscous friction effect. The following are described and analyzed: solution of the wave equation in the form binding four variables: pressure and flow rate at the line input, and pressure and flow rate and the line output; two of the above-mentioned variables should be regarded as independent (input) and the other two as dependent (output), the accuracy comparison of distributed parameters model to lumped parameters model with regard to applicability range in hydraulic systems analysis, pressure value at given installation points as a response to rapid valve closing (transient response) or to valve opening (waterhammer effect). In these considerations the hydraulic line is regarded as a two-port with two inputs and two outputs with a definite transmittance matrix. Main considerations concern the variable resistance model. A general solution is given as a function of the Laplace operator. Introducing appropriate simplifications into the variable resistance model, the constant resistance model and lossless line model is obtained. Also, general solutions for three different lump parameter models are presented. For the lumped parameters lin presents three equivalent models possible, i.e. as: a symmetrical two-port, a two-port with shared resistance and a two-port with capacitance at the output.
Źródło:
Journal of KONES; 2010, 17, 3; 467-475
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of the continuous traverse trajectory and dynamic error of the vane anemometer on the accuracy of average velocity measurements at the cross-section of the mine heading – model-based testing
Wpływ trajektorii trawersu ciągłego oraz błędu dynamicznego anemometru skrzydełkowego na dokładność pomiaru prędkości średniej w przekroju wyrobiska kopalnianego – badania modelowe
Autorzy:
Jamróz, P.
Powiązania:
https://bibliotekanauki.pl/articles/219564.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
strumień objętości powietrza
trawers ciągły
profil prędkości
anemometr skrzydełkowy
błąd dynamiczny
air volume flow
continuous traverse
velocity profile
vane anemometer
dynamic error
Opis:
This paper discusses the problem of measuring the average velocity at the cross-section of mine heading with the use of the continuous traverse method. Based on model testing, it has been shown that measurement signals, obtained along the traversing trajectory, belong to the group of non-stationary signals. The methodology of the traversing method measurements, with the aspect of capabilities of measuring instruments used for that purpose, has been analysed. Results of simulation tests concerning the dynamic response of a vane anemometer to the measurement signal for selected trajectories of the continuous traverse have been presented. For this purpose, a velocity profile presenting an expanded stream of undisturbed air flow in the excavation has been used. Attention has been paid to the problem of selecting an adequate trajectory of anemometer movement, as the value of the velocity measured at the cross-section depends on the trajectory.
W artykule poruszono problem pomiarów prędkości średniej w przekroju wyrobiska kopalnianego z wykorzystaniem metody trawersu ciągłego. Na podstawie badań modelowych wykazano, że sygnały pomiarowe, które uzyskuje się wzdłuż trajektorii trawersowania należą do grupy sygnałów niestacjonarnych. Przeanalizowano metodologię przeprowadzania pomiarów metodą trawersowania w aspekcie możliwości pomiarowych wykorzystywanych w tym celu urządzeń pomiarowych. Przedstawiono wyniki badań symulacyjnych dynamicznej odpowiedzi anemometru skrzydełkowego na sygnał pomiarowy dla wybranych trajektorii trawersu ciągłego. W tym celu wykorzystano profil prędkości przedstawiający rozwiniętą strugę niezakłóconego przepływu powietrza w chodniku. Zwrócono uwagę na problem doboru odpowiedniej trajektorii przemieszczania anemometru, od której zależy wartość mierzonej prędkości średniej w przekroju.
Źródło:
Archives of Mining Sciences; 2014, 59, 4; 1051-1060
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flow simulations in cross-flow fans using the finite element and finite volume methods
Autorzy:
Sowa, A.
Powiązania:
https://bibliotekanauki.pl/articles/1955710.pdf
Data publikacji:
2004
Wydawca:
Politechnika Gdańska
Tematy:
turbomachinery
cross-flow fan
finite element method
finite volume method
usteady flow analysis
Opis:
Both basic computational fluid dynamics methods: the finite element method (FEM) and the finite volume method (FVM) have been used to simulate flow fields in a cross-flow fan (CFF). A review of previous numerical simulations of flow in CFF's is presented. The theorethical foundations of the applied numerical algorithms and specifications of the computer programs are given. The procedure of computations is described in detail. Computational results are shown in the form of contour and vector velocity and contour pressure plots.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2004, 8, 1; 41-49
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simplified Volume of Fluid Method (SVOF) for two-phase flows
Autorzy:
Marek, M.
Aniszewski, W.
Bogusławski, A.
Powiązania:
https://bibliotekanauki.pl/articles/1943237.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska
Tematy:
two-phase flow modeling
volume of fluid
eulerian simulation
Opis:
The PLIC approach has been usually used in recent implementations of the VOF method i.e. the interphasal surface is approximated by a plane with an arbitrary orientation with respect to the computational cell. Although this method is accurate, it is rather difficult to implement, as a large number of orientations need to be taken into account and the calculation of volume fraction fluxes is not straightforward. A simpler approach to VOF – SLIC – requires much less effort from the programmer but the interface approximation by a plane parallel to the cell surfaces is too crude and the results are not satisfactory. The method presented in the article may be considered as an intermediate approach between PLIC and SLIC – fluxes are computed directly only for the interface’s special orientations and linear interpolation is used for calculation of the fluxes for the remaining cases. Some classical tests of the proposed method are performed and an example of a broken dam problem simulation is presented.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2008, 12, 3-4; 255-265
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation and analysis of a turbulent flow around a three-dimensional obstacle
Autorzy:
Benahmed, Lamia
Aliane, Khaled
Powiązania:
https://bibliotekanauki.pl/articles/386769.pdf
Data publikacji:
2019
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
turbulent flow
obstacle
finite volume
turbulence models
ANSYS CFX
Opis:
The study of flow around obstacles is devised into three different positions: above the obstacle, upstream of the obstacle, and downstream of the latter. The behaviour of the fluid downstream of the obstacle is less known, and the physical and numerical modelling is being given the existence of recirculation zones with their complex behaviour. The purpose of the work presented below is to study the influence of the inclined form of the two upper peaks of a rectangular cube. A three-dimensional study was carried out using the ANSYS CFX calculation code. Turbulence models have been used to study the flow characteristics around the inclined obstacle. The timeaveraged results of contours of velocity vectors , cross-stream and stream wise velocity and streamlines were obtained by using K-ω shear -stress transport (SST), RANG K-ε and K-ε to model the turbulence, and the governing equations were solved using the finite volume method. The turbulence model K-ω SST has presented the best prediction of the flow characteristics for the obstacle among the investigated turbulence models in this work.
Źródło:
Acta Mechanica et Automatica; 2019, 13, 3; 173-180
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical heat transfer in a rectangular channel with mounted obstacle
Autorzy:
Gareh, S.
Powiązania:
https://bibliotekanauki.pl/articles/412607.pdf
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
laminar flow
obstacle
finite volume
simulation
convective heat transfer
Opis:
The fully-incompressible, viscous and stationary Navier–Stokes equations are solved for the laminar flow over an obstacle placed on the lower of a channel. The Reynolds number is varied from 100 to 400. In all cases studied the flow field proves to be steady. Several distinct flow features are identified: a horseshoe vortex system, inward bending flow at the side walls of the obstacle, a horizontal vortex at the downstream lower-half of the obstacle and a downstream wake containing two counter-rotating vortices. The shape and size of these flow features are mainly dominated by the Reynolds number. For higher Reynolds numbers, both the horseshoe vortex and the wake region extend over a significantly larger area. The correlation of the position of the separation and attachment point with the Reynolds number has been calculated. A detailed analysis is carried out to investigate flow pattern and Nusselt number.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2014, 19, 2; 111-119
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Unstructured finite-volume meshes for two-dimensional flow in variably saturated porous media
Autorzy:
Burzyński, K.
Szymkiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/1934018.pdf
Data publikacji:
2011
Wydawca:
Politechnika Gdańska
Tematy:
finite volume method
Richards' equation
unsaturated flow
unstructured mesh
Opis:
This paper presents a numerical algorithm for solving the equation describing variably saturated flow in porous media. The algorithm is based on a control volume finite element approach and can be applied to two-dimensional unstructured meshes consisting of triangular elements. Two methods of defining the dual control volume grid are discussed. We also demonstrate that the method of calculating the average permeability at the control volume face significantly influences numerical results.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2011, 15, 3-4; 339-352
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Weryfikacja metod obliczania udziału objętościowego gazu
Verification of methods used for gas volume fraction calculation
Autorzy:
Czernek, K.
Okoń, P.
Powiązania:
https://bibliotekanauki.pl/articles/2073324.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
udział objętościowy
przepływ dwufazowy
volume fraction
two-phase flow
Opis:
Przedstawiono wyniki obliczeń wpływu parametrów hydrodynamicznych na udział objętościowy faz podczas przepływu w rurach pionowych mieszaniny dwufazowej gazu i cieczy. Dokonano oceny dokładności wybranych metod obliczeniowych uwzględniających parametry hydrodynamiczne i określono przydatność metod w obliczeniach procesowych aparatów wykorzystujących tę formę przepływu.
The calculation results of hydrodynamic parameters’ impact on a volume fraction in gas-liquid two-phase flow in vertical pipes are presented in the paper. The accuracy of selected calculation methods cited in literature was evaluated for various hydrodynamic parameters. The usefulness and accuracy of these methods in process calculations of apparatus in which this type of flow exist were determined.
Źródło:
Inżynieria i Aparatura Chemiczna; 2018, 3; 51--52
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies