Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "flight time" wg kryterium: Temat


Tytuł:
The effect of warm-up modalities on trampoline flight time performance
Autorzy:
Harden, Melissa
Earnest, Conrad P.
Powiązania:
https://bibliotekanauki.pl/articles/1054947.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
bounce height
flight time
muscle activation
trampoline
Opis:
Trampoline flight time is a recent addition to Olympic scoring and was sufficient in weight to displace a formed medal winner from a podium placement at the 2012 Olympics. The aim of our study was to examine different warm-up routines on trampoline flight time. We examined ten elite, female trampolinists (mean ± SD: age 19.2 ±5.4 y) who performed six different warm-up routines in a randomised, cross-over, counter-balanced manner: (a) static stretching (STAT, control), (b) STAT+10 trampoline bounces, (c) dynamic stretching (DYN), (d) DYN+10 trampoline bounces, (e) DYN+Drop jumps (DYN+DJ) and (f) DYN+isometric mid-thigh pulls (DYN+IP). Data were analysed using general linear models, Dunnett-HSU post-hoc tests vs. Control/STAT and magnitude based inferences vs. control. Our analysis demonstrated that total flight time following DYN 10 (17.29 ±0.52s, 83% likely beneficial, P < 0.002) was significantly longer versus STAT (16.59 ±0.49 s), with a trend toward significance for DYN (16.97 ±0.20 s; 22% likely beneficial, P = 0.077). The DYN-IP (14.04 ± 0.48 s) and DYN-DJ (14.15 ±0.66 s) produced the shortest vs. all warm-up forms (P < 0.005). To the contrary, the DYN+DJ and DYN+IP conditions were >99% likely to be detrimental to performance. Our results demonstrate a clear improvement in flight times when using a dynamic warm-up coupled with a trampoline specific bouncing task (DYN+10).
Źródło:
Central European Journal of Sport Sciences and Medicine; 2015, 10, 2; 33-43
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laser-induced ablation: physics and diagnostics of ion emission
Autorzy:
Torrisi, L.
Powiązania:
https://bibliotekanauki.pl/articles/146624.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
laser-generating plasma
Boltzmann distribution
time-of-flight
Opis:
Pulsed lasers generating beams of different intensities may be used to produce ablation of solid targets placed in high vacuum and to generate pulsed plasma and ion acceleration. The plasma is in a non-equilibrium condition and in the first instant the particles being generated are subject to thermal interactions, to a supersonic gas expansion in vacuum and to a Coulomb acceleration due to the high electric field developed along the normal to the target surface. The ion diagnostics, based on time-of-flight technique, allow us to measure the mean ion energy, the total number of ions, as well as the ion energy and charge state distributions. The ion energy distributions may be described by the Coulomb- -Boltzmann-Shifted (CBS) function, which after fitting to the experimental data may be used to determine the equivalent ion temperature and the accelerating voltage. Given the equivalent acceleration voltage and the plasma Debye length, it is possible to estimate the magnitude of the electric field developed in the plasma. Measurements of the ablation yield, plasma dimension and optical spectroscopy allow us to calculate the atomic and electronic plasma density and to evaluate the coronal plasma temperature. Some applications of the laser-induced ablation consist in the realization of laser ion sources (LIS), generation of multi-energetic ion beams by using a post-accelerating voltage, use of ultra-intense fs lasers to accelerate ions to energies of the order of tens MeV/nucleon. Other special applications include the pulsed laser deposition (PLD) of thin films, the laser ablation coupled to mass quadrupole spectrometry (LAMQS) probes, ablation of biological tissues, and generation of plasma for astrophysical and nuclear investigations.
Źródło:
Nukleonika; 2011, 56, 2; 113-117
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the compress sensing theory for improvement of the TOF resolution in a novel J-PET instrument
Autorzy:
Raczyński, L.
Moskal, P.
Kowalski, P.
Wiślicki, W.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Rudy, Z.
Salabura, P.
Gupta-Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/146280.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
compressed sensing
positron emission tomography
time-of-flight
Opis:
Nowadays, in positron emission tomography (PET) systems, a time of fl ight (TOF) information is used to improve the image reconstruction process. In TOF-PET, fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten signifi cantly a range along the line-of-response (LOR) where the annihilation occurred. In the new concept, called J-PET scanner, gamma rays are detected in plastic scintillators. In a single strip of J-PET system, time values are obtained by probing signals in the amplitude domain. Owing to compressive sensing (CS) theory, information about the shape and amplitude of the signals is recovered. In this paper, we demonstrate that based on the acquired signals parameters, a better signal normalization may be provided in order to improve the TOF resolution. The procedure was tested using large sample of data registered by a dedicated detection setup enabling sampling of signals with 50-ps intervals. Experimental setup provided irradiation of a chosen position in the plastic scintillator strip with annihilation gamma quanta.
Źródło:
Nukleonika; 2016, 61, 1; 35-39
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of doping on time-of-flight transient currents in twin crystalline layers: a Monte-Carlo study
Autorzy:
Rybicki, J.
Powiązania:
https://bibliotekanauki.pl/articles/1941715.pdf
Data publikacji:
2000
Wydawca:
Politechnika Gdańska
Tematy:
hopping transport
time-of-flight experiment
Monte Carlo methods
Opis:
In the paper we present the results of the Monte Carlo simulations of time-of-flight transient currents in hopping systems containing various, concentrations of transport-active centres placed in an inert matrix, and doped with various concentrations of additional transport-active centres, characterised by a different ionisation potential than the host transport centres. Such hopping centre distribution can be found in molecularly doped organic crystals. The carriers are allowed to jump between localised states of two kinds: the host transport sites of concentration c/sub 0/, and the additional doping sites of concentration c/sub d/. We deal only with the dependence of the carrier mobility on doping level, and on the difference of ionisation potentials between the host and dopant centres, at fixed external field and temperature. The results of simulations performed for various dopings, and various hopping sites distributions in energy, are discussed. The carrier jump statistics is discussed in detail.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2000, 4, 1; 33-48
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Enhanced microdialysis of neuropeptides.
Autorzy:
Pettersson, Andreas
Markides, Karin
Bergquist, Jonas
Powiązania:
https://bibliotekanauki.pl/articles/1044057.pdf
Data publikacji:
2001
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
neuropeptides
electrospray ionization orthogonal time-of-flight mass spectrometry
enhanced microdialysis
Opis:
An enhanced microdialysis method for neuropeptides is described and some preliminary results of this novel approach are presented. The enhancement is achieved by adding a vehicle (solid support) to the perfusion fluid in order to increase the diffusion coefficient across the membrane and efficiently transport the analytes towards the detector. The microdialysis samples are desalted and then analyzed on an electrospray ionization orthogonal time-of-flight mass spectrometer. The preliminary results show major increase in signal when comparing this new approach of microdialysis with ordinary microdialysis.
Źródło:
Acta Biochimica Polonica; 2001, 48, 4; 1117-1119
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of MALDI-TOF MS for dermatophyte identification
Autorzy:
Dabrowska, I.
Dworecka-Kaszak, B.
Powiązania:
https://bibliotekanauki.pl/articles/6182.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Parazytologiczne
Tematy:
application
MALDI-TOF MS zob.matrix-assisted laser desorption-ionization time-of-flight mass spectrometry
matrix-assisted laser desorption-ionization time-of-flight mass spectrometry
dermatophyte
identification
detection
fungi
mammal
skin disease
hair
nail
Opis:
Dermatophytes are keratinolytic fungi responsible for a wide variety of diseases of the skin, nails and hair of mammals. Their identification is often complicated, labor-intensive and time consuming due to the high degree of intra-species morphological similarity, and also requires scientific knowledge and practice. The aim of this study was to demonstrate that MALDI-TOF MS technique may be a faster and more sophisticated method useful for the identification of dermatophytes and mycoses in general.
Źródło:
Annals of Parasitology; 2014, 60, 3
0043-5163
Pojawia się w:
Annals of Parasitology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Applying hand gesture recognition with time-of-flight camera for 3D medical data analysis
Autorzy:
Malawski, F.
Powiązania:
https://bibliotekanauki.pl/articles/115723.pdf
Data publikacji:
2014
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Tematy:
human-computer interaction
hand gesture recognition
time-of-flight camera
interakcja człowiek-komputer
rozpoznawanie gestów dłoni
czas przelotu kamery
Opis:
This paper describes a human-computer interface based on hand gesture recognition, intended for analysis of 3D medical data. The gestures are designed to minimize the required muscle tension when using the system. Gesture recognition is based on a 3D sensor. Depth maps are acquired by a time-of-flight camera, designed specifically for hand gestures recognition. The depth images are denoised and segmented to right and left hand. The contours of the hands are found and a modified Shape Context descriptor is utilized for each hand, providing a set of features, which are employed to train and test various classifiers. Naive Bayes, Random Forest and Support Vector Machine (SVM) classifiers are utilized, with search of optimal parameters using cross-validation. The best accuracy (95%) is achieved with the Support Vector Machine classifier. The gestures are mapped to various controls of a 3D medical visualization module. Two visualization methods are employed - isosurface and cut-planes. The left hand is assigned to switching between different control modes and the right hand gestures are corresponding to controlling various properties in each mode. The system is convenient to use and runs in real-time on a typical PC machine.
Źródło:
Challenges of Modern Technology; 2014, 5, 4; 12-16
2082-2863
2353-4419
Pojawia się w:
Challenges of Modern Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New instrument for measuring the velocity of sound in gases and quantitative characterization of binary gas mixtures
Autorzy:
Koturbash, T.
Bicz, A.
Bicz, W.
Powiązania:
https://bibliotekanauki.pl/articles/114208.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ultrasonic measurement
velocity of sound
speed of sound
natural gas
time of flight
characterization of gas mixture
analysis of gas mixture
Opis:
A new instrument for precise measurements of velocity of sound in gases was developed and tested. The instrument implements improved velocity of sound measuring technique based on time-of-flight measurement of ultrasonic pulses. The instrument was developed primarily for conducting measurements in natural gas, it can operate in wide ranges of natural gas compositions as well as other gas mixtures with velocity of sound parameter in range of 200 to 500 m/s. The instrument allows conducting measurement of velocity of sound propagation in various gas mixtures with average repeatability of equal to ±1 cm/s at normal conditions. The accuracy of measurement depends on calibration conditions and approach, and has good agreement with theoretically calculated values. The instrument has a modular design of control unit and flow-through measuring chamber. The set of distinctive features and adjustable measuring parameters of the instrument allows further improving of applicability for other gases and gas mixtures and various measurement conditions. The instrument showed good performance in the task of quantitative characterization of binary gas mixtures by velocity of sound parameter.
Źródło:
Measurement Automation Monitoring; 2016, 62, 8; 254-258
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie analizatorów czasu przelotu w kryminalistyce
Autorzy:
Ulanowska, A.
Strączyński, G.
Powiązania:
https://bibliotekanauki.pl/articles/273915.pdf
Data publikacji:
2012
Wydawca:
Roble
Tematy:
analizator czasu przelotu jonów
TOF
badania kryminalistyczne
chromatografia gazowa
spektrometria masowa
time-of-flight analyzer
crime research
gas chromatography
mass spectrometry
Źródło:
LAB Laboratoria, Aparatura, Badania; 2012, 17, 3; 37-40
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wysokorozdzielcza spektrometria mas czasu przelotu w oznaczaniu dioksyn
Autorzy:
Ulanowska, A.
Strączyński, G.
Powiązania:
https://bibliotekanauki.pl/articles/274286.pdf
Data publikacji:
2013
Wydawca:
Roble
Tematy:
dioksyny
oznaczanie dioksyn
spektrometria masowa czasu przelotu
chromatografia gazowa
GC-TOFMS
dioxins
dioxin determination
time-of-flight mass spectrometry
gas chromatography
Źródło:
LAB Laboratoria, Aparatura, Badania; 2013, 18, 1; 11-14
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Semi-Supervised Siamese Network for Complex Aircraft System Fault Detection with Limited Labeled Fault Samples
Autorzy:
Xinyun, Zhu
Sun, Jianzhong
Hu, Hanchun
Li, Chunhua
Powiązania:
https://bibliotekanauki.pl/articles/28086935.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
fault detection
semi-supervised
aircraft system
flight data
time-series data
Opis:
Health monitoring and fault detection of complex aircraft systems are paramount for ensuring reliable and efficient operation. The availability of monitoring data from modern aircraft onboard sensors provides a wealth of big data for developing deep learning-based fault detection methods. However, aircraft onboard systems typically have limited labeled fault samples and large amounts of unlabeled data. To better utilize the information contained in limited labeled fault samples, a deep learning-based semi-supervisedfault detection method is proposed, which leverages a small number of labeled fault samples to enhance its performance. A novel sample pairing strategy is introduced to improve algorithm performance by iteratively utilizing fault samples. A comprehensive loss function is employed to accurately reconstruct normal samples and effectively separate fault samples. The results of a case study using real data from a commercial aircraft fleet demonstrate the superiority of the proposed method over existing techniques, with improvements of approximately 16.7% in AP, 9.5% in AUC, and 19.2% in F1 score. Ablation studies confirm that performance can be further improved by incorporating additional labeled fault samples during training. Furthermore, the algorithm demonstrates good generalization ability.
Źródło:
Eksploatacja i Niezawodność; 2023, 25, 4; art. no. 174382
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling 3D Objects for Navigation Purposes Using Laser Scanning
Autorzy:
Specht, C.
Dąbrowski, P.
Dumalski, A.
Hejbudzka, K.
Powiązania:
https://bibliotekanauki.pl/articles/117139.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Morski w Gdyni. Wydział Nawigacyjny
Tematy:
modeling 3D objects
laser scanning
3D objects
urban navigation
complex building navigation
Global Positioning System (GPS)
Gdynia Maritime University (GMU)
time of flight (TOF)
Opis:
The paper discusses the creation of 3d models and their applications in navigation. It contains a review of available methods and geometric data sources, focusing mostly on terrestrial laser scanning. It presents detailed description, from field survey to numerical elaboration, how to construct accurate model of a typical few storey building as a hypothetical reference in complex building navigation. Hence, the paper presents fields where 3d models are being used and their potential new applications.
Źródło:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation; 2016, 10, 2; 301-306
2083-6473
2083-6481
Pojawia się w:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe perspektywy w analizie żywności
Autorzy:
Ulanowska, A.
Strączyński, G.
Powiązania:
https://bibliotekanauki.pl/articles/273987.pdf
Data publikacji:
2012
Wydawca:
Roble
Tematy:
analiza żywności
chromatografia gazowa
spektrometria masowa
analizator czasu przelotu jonów
TOF
układ dwuwymiarowy
food analysis
gas chromatography
mass spectrometry
time-of-flight analyzer
2D positive system
Źródło:
LAB Laboratoria, Aparatura, Badania; 2012, 17, 4; 31-34
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of gliders trajectory for given thermal conditions
Optymalizacja trajektorii szybowca dla zadanych warunków termicznych
Autorzy:
Rogowski, K.
Maroński, R.
Powiązania:
https://bibliotekanauki.pl/articles/140057.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
lot ślizgowy
zagadnienie minimalno-czasowe
pseudospektralna metoda Czebyszewa
soaring flight
minimum-time problem
pseudospectral Chebyshev's method
Opis:
The minimum-time problem for a glider flying in the vertical plane is considered. The glider is regarded as a particle moving in the atmosphere in given thermal conditions. The problem is formulated in optimal control and solved using direct pseudospectral Chebysev's method. The data are taken for the Word Class Glider PW-5 "Smyk". Computed optimum results are compared with glider's trajectories from the Second Domestic Glider Championship 2006, Suwałki, Poland.
Rozważono zagadnienie minimalno-czasowe ruchu szybowca w płaszczyźnie pionowej. Szybowiec jest modelowany jak uskrzydlony punkt materialny poruszający się w atmosferze przy zadanych warunkach termicznych. Zagadnienie zostało sformułowane za pomocą formalizmu teorii sterowania optymalnego. Rozwiązano je bezpośrednią pseudospektralną metodą Czebyszewa. Wykorzystano dane dla szybowca Klasy Światowej PW-5 "Smyk". Wyznaczone trajektorie optymalne porównano z trajektoriami uzyskanymi w czasie Drugich Krajowych Zawodów Szybowcowych w Suwałkach w 2006 roku.
Źródło:
Archive of Mechanical Engineering; 2011, LVIII, 1; 11-25
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie LC/QTOF w analizach metabolomicznych – zalety, ograniczenia i wyzwania
Autorzy:
Fornal, E.
Warpas, A.
Wójcicka, G.
Bełtowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/273557.pdf
Data publikacji:
2017
Wydawca:
Roble
Tematy:
analiza metabolomiczna
chromatografia cieczowa sprzężona ze spektrometrią mas
spektrometr z kwadrupolem i analizatorem czasu przelotu
LC/MS
LC/QTOF
metabolomic analysis
liquid chromatography coupled with mass spectrometry
quadrupole time-of-flight mass spectrometer
Opis:
Spektrometria mas sprzężona z chromatografią cieczową (LC/MS) lub chromatografią gazową oraz spektroskopia magnetycznego rezonansu jądrowego (NMR) są trzema technikami analitycznymi, które umożliwiają i w największym stopniu przyczyniają się obecnie do rozwoju badań metabolomicznych. Wśród technik LC/MS szczególną rolę odgrywają te zapewniające dokładny pomiar masy. W badaniach metabolomicznych najczęściej wykorzystywane są wysokorozdzielcze spektrometry mas (HRMS) typu kwadrupol-analizator czasu przelotu jonów (QTOF) oraz Orbitrap. W pracy przedstawiono przykłady zastosowań LC/QTOF w analizach metabolomicznych, krótko omówiono rolę optymalizacji metody analitycznej do badań metabolomicznych, wskazano zalety i ograniczenia techniki oraz wyzwania i perspektywy jej rozwoju w tym obszarze badawczym.
Źródło:
LAB Laboratoria, Aparatura, Badania; 2017, 22, 3; 29-34
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies