Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "extremely low frequency" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Biological risk assessment of high-voltage transmission lines on worker’s health of electric society
Autorzy:
Bidi, Manel
Powiązania:
https://bibliotekanauki.pl/articles/141717.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biological risk
electromagnetic fields
extremely low frequency
induced current
overhead lines
Opis:
A probable risk for different diseases has been reported due to exposure of peoples living in the vicinity of electrical substations and electrical workers. The aim of this paper is to examine and reduce the induced current density due to the power system field acting on human beings in the working environment, by using the spheroidal calculation model. The results obtained by means of computer programs developed by the author in the MATLAB environment are compared with the limit values given by the International Committee on Non-Ionizing Radiation Protection (ICNIRP) for demonstrating the degree of danger due to the induced current and have a certain guidance function for worker’s health to ensure their safety
Źródło:
Archives of Electrical Engineering; 2020, 69, 1; 57-68
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ pola magnetycznego o ekstremalnie niskiej częstotliwości na zawartość glutationu w mięśniu poprzecznie prążkowanym szczura
Effect of extremely low frequency magnetic field on glutathione in rat muscles
Autorzy:
Ciejka, Elżbieta
Jakubowska, Ewa
Żelechowska, Paulina
Huk-Kolega, Halina
Kowalczyk, Agata
Gorąca, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2166235.pdf
Data publikacji:
2014-10-27
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
pole magnetyczne ekstremalnie niskiej częstotliwości
ELF-MF
glutation
extremely low frequency magnetic field
glutathione
Opis:
Wstęp: Wolne rodniki to atomy, cząsteczki lub ich fragmenty, których nadmiar prowadzi do rozwoju stresu oksydacyjnego, będącego przyczyną wielu chorób, m.in. nowotworowych, neurodegeneracyjnych i zapalnych, oraz starzenia się organizmu. Głównymi egzogennymi źródłami wolnych rodników są m.in. zanieczyszczenia przemysłowe, dym tytoniowy, promieniowanie jonizujące, ultradźwięki i pole magnetyczne. Pole magnetyczne niskiej częstotliwości powszechnie stosowane jest w terapii fizykalnej. Celem pracy była ocena wpływu pola magnetycznego niskiej częstotliwości (extremely low frequency magnetic field - ELF-MF), stosowanego w magnetoterapii, na zawartość glutationu całkowitego, utlenionego i zredukowanego oraz stanu redoks w komórce mięśnia poprzecznie prążkowanego w zależności od czasu działania pola. Materiał i metody: Materiał badawczy stanowiły szczury, samce o wadze 280-300 g. Zwierzęta podzielono na 3 grupy badawcze: I - grupa kontrolna, II grupa - poddana 30 min/dzień przez 2 tygodnie działaniu pola magnetycznego o parametrach: 7 mT i 40 Hz, III grupa - poddana 60 min/dzień przez 2 tygodnie działaniu pola magnetycznego o parametrach: 7 mT i 40 Hz. U zwierząt oznaczono glutation całkowity, utleniony i zredukowany oraz stan redoks w homogenatach tkanki mięśniowej po zakończeniu ekspozycji na działanie pola magnetycznego. Wyniki: Eksponowanie szczurów 30 min/dzień i 60 min/dzień przez 2 tygodnie na pole magnetyczne o parametrach 40 Hz i 7 mT powodowało istotny wzrost stężenia glutationu całkowitego w mięśniu poprzecznie prążkowanym w porównaniu z wynikami grupy kontrolnej (p < 0,001). Wnioski: Uzyskane wyniki sugerują, że glutation odgrywa ważną rolę w ochronie tkanek przed polem magnetycznym. Ekspozycja na pole magnetyczne stosowane w magnetoterapii prowadzi do rozwoju mechanizmów adaptacyjnych, których celem jest utrzymanie równowagi oksydacyjno-redukcyjnej organizmu, i zależy od czasu ekspozycji. Med. Pr. 2014;65(3):343–349
Background: Free radicals (FR) are atoms, molecules or their fragments. Their excess leads to the development of oxidizing stress, the cause of many neoplastic, neurodegenerative and inflammatory diseases, and aging of the organism. Industrial pollution, tobacco smoke, ionizing radiation, ultrasound and magnetic field are the major FR exogenous sources. The low frequency magnetic field is still more commonly applied in the physical therapy. The aim of the presented study was to evaluate the effect of extremely low frequency magnetic field used in the magnetotherapy on the level of total glutathione, oxidized and reduced, and the redox state of the skeletal muscle cells, depending on the duration of exposure to magnetic field. Material and Methods: The male rats, weight of 280-300 g, were randomly devided into 3 experimental groups: controls (group I) and treatment groups exposed to extremely low frequency magnetic field (ELF-MF) (group II exposed to 40 Hz, 7 mT for 0.5 h/day for 14 days and group III exposed to 40 Hz, 7 mT for 1 h/day for 14 days). Control rats were kept in a separate room not exposed to extremely low frequency magnetic field. Immediately after the last exposure, part of muscles was taken under pentobarbital anesthesia. Total glutathione, oxidizedand reduced, and the redox state in the muscle tissue of animals were determined after exposure to magnetic fields. Results: Exposure to low magnetic field: 40 Hz, 7 mT for 30 min/day and 60 min/day for 2 weeks significantly increased the total glutathione levels in the skeletal muscle compared to the control group (p < 0.001). Conclusions: Exposure to magnetic fields used in the magnetic therapy plays an important role in the development of adaptive mechanisms responsible for maintaining the oxidation-reduction balance in the body and depends on exposure duration. Med Pr 2014;65(3):343–349
Źródło:
Medycyna Pracy; 2014, 65, 3; 343-349
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Środowiskowa ocena ekspozycji dzieci na wolnozmienne pola magnetyczne w budynkach szkolnych z terenu Tychów, usytuowanych w pobliżu transformatorów energetycznych
Environmental exposure of primary school buildings located in Tychy to extremely low frequency magnetic fields from nearby transformers
Autorzy:
Zieliński, Grzegorz
Harazin, Barbara
Mroczek, Alina
Malinowska-Borowska, Jolanta
Szołtysik, Izabela
Powiązania:
https://bibliotekanauki.pl/articles/1038952.pdf
Data publikacji:
2012
Wydawca:
Śląski Uniwersytet Medyczny w Katowicach
Tematy:
wolnozmienne pole magnetyczne
szkoły
ekspozycja
transformatory
uczniowie
extremely low frequency magnetic fi elds
schools
exposition
transformer
pupils
Opis:
INTRODUCTION In city agglomerations, educational establishments are very often within the vicinity of energy infrastructure such as, power lines, distribution transformers; power distribution rooms, mobile phone base stations and overhead tramway power lines. The levels of magnetic fields in the classrooms of such educational establishments are not well known. MATERIAL AND METHODS Ten primary schools from Tychy were chosen for the study, all of which are located within a radius of 100 meters from distribution transformers. The magnetic induction was measured in at least two classrooms, i.e. in the information technology classroom and a humanistics classroom. RESULTS Based on visual inspection, it was ascertained that for two schools, the transformers were installed at a distance of not more than 20 m. In one school the distance is 15 m and in another there was an aerial voltage line at a distance of 20 m. The latter school contained elevators. In the humanistics classroom adjacent to the elevator shaft, an induction level of 110 nT was measured. In one of the three oldest schools tested, which was 125 years old, the measured magnetic induction levels were even higher: in the humanistic classroom – 226 nT and in the computer studies classroom – 59 nT. We also found that for 10 schools, the magnetic induction levels were higher in the information technology classroom than in the humanistics classroom. CONCLUSIONS Transformers installed within the vicinity of school buildings do not influence the magnetic induction levels within classrooms and school premises.
WSTĘP W aglomeracjach miejskich bardzo często placówki oświatowe zlokalizowane są w pobliżu infrastruktury energetycznej, takiej jak: przesyłowe linie energetyczne, stacje transformatorowe, rozdzielnie napięć, stacje bazowe telefonii komórkowej, sieci trakcji tramwajowej. Nie są znane poziomy pól magnetycznych w salach lekcyjnych tak usytuowanych budynków szkolnych. Celem podjętych badań była ocena poziomu indukcji magnetycznej w klasach i pracowniach budynków szkolnych usytuowanych w pobliżu stacji transformatorowo-rozdzielczych. MATERIAŁ I METODY Do badań wybrano 10 szkół podstawowych z terenu Tychów, w pobliżu których (w promieniu 100 metrów) zainstalowane były transformatory. Indukcję magnetyczną mierzono co najmniej w dwóch salach lekcyjnych (w pracowni informatycznej i pracowni do przedmiotów humanistycznych). WYNIKI Na podstawie przeprowadzonej wizji lokalnej stwierdzono, że tylko w dwóch szkołach transformatory energetyczne zainstalowane zostały w odległości nieprzekraczającej 20 m. W odległości 15 m od jednej ze szkół zainstalowany był transformator, a w odległości 20 m przebiegała napowietrzna linia elektryczna niskiego napięcia. W szkole tej, wewnątrz budynku, stwierdzono windę towarową. Zmierzony w sali humanistycznej sąsiadującej z tunelem windy poziom indukcji wynosił 110 nT. W jednej z trzech najstarszych badanych szkół (125-letniej) poziomy indukcji magnetycznej były jeszcze wyższe: w klasie humanistycznej 226 nT, a w pracowni informatycznej 59 nT. Wykazano ponadto, że w 6 spośród 10 zbadanych pracowni informatycznych poziomy indukcji magnetycznej były wyższe niż w klasach humanistycznych. WNIOSKI Transformatory zainstalowane w pobliżu budynków szkolnych nie miały wpływu na zmierzoną indukcję magnetyczną w klasach i pomieszczeniach szkolnych.
Źródło:
Annales Academiae Medicae Silesiensis; 2012, 66, 5; 54-61
1734-025X
Pojawia się w:
Annales Academiae Medicae Silesiensis
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies