The role of the type of insulating liquid in the transformer temperature distribution
Autorzy:
Dombek, G.
Nadolny, Z.
Przybyłek, P.
Powiązania:
https://bibliotekanauki.pl/articles/97345.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
mineral oil
synthetic ester
natural ester
power transformers
Opis:
The mineral oil is most frequently used liquid in insulation transformer system. However, increased interest in alternative insulating liquid for it, which includes synthetic ester and natural ester is observable for several years. However, for several years, the increased interest in insulating liquids as alternatives to mineral oil is observable, which include synthetic ester and natural ester. This is due to increasingly restrictive environmental legislation and fire safety. Mineral oil, in comparison with esters has a very good electric insulation properties and a lower viscosity. In turn the esters in comparison with oil, have a much greater biodegradability and have a much higher flash point, which suggests their favor. The influence of the type of insulating liquid on the efficiency of the cooling system of the transformer was presented in the paper. This efficiency was determined by designating the heat transfer coefficient α by liquids. This factor depends on the thermal properties of liquids, which includes the thermal conductivity λ, kinematic viscosity υ, specific heat cp, density ρ, and thermal expansion β. For the study mineral oil, synthetic ester and natural ester were used. The measurements of thermal properties were carried out in the temperature range from 25°C to 80°C.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 148-157
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of heat transfer coefficient of synthetic and natural ester in the aspect of their application in power transformer
Autorzy:
Gościński, P.
Dombek, G.
Nadolny, Z.
Bródka, B.
Powiązania:
https://bibliotekanauki.pl/articles/97728.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
heat transfer coefficient
high voltage power transformers
synthetic ester
natural ester
Opis:
Insulating liquids due to their properties are used in electrical power transformers, capacitors, connectors and high voltage power cables. One of the most important tasks for electrical insulating liquids is a heat transport out of the device. The heat transfer in the liquids depends on heat transfer coefficient. The heat transfer coefficient depends on a viscosity, thermal conductivity coefficient and thermal expansion coefficient. This paper shows results of calculations for heat transfer coefficient of insulating liquids used as insulation in electrical equipment, depending on the kind of liquid and temperature. Synthetic ester oil and natural ester oil were analyzed. The range of the temperature was changing from 25°C to 80°C.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 376-385
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza opłacalności produkcji estrów metylowych oleju rzepakowego na przykładzie wytwórni rolniczej W-400
Profitability analysis for production of rape-seed oil methyl esters on the example of the W-400 agricultural production plant
Autorzy:
Bieniek, J.
Molendowski, F.
Kopa, D.
Powiązania:
https://bibliotekanauki.pl/articles/288636.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
rzepak
ester metylowy
biodiesel
koszt produkcji
opłacalność
rape
methyl ester
production costs
Opis:
Celem pracy była ocena kosztów oraz opłacalności produkcji estrów metylowych oleju rzepakowego przy użyciu małej wytwórni biodiesla. Przedmiotem badań była wytwórnia W-400. W celu określenia opłacalności produkcji estrów wyznaczono: koszty produkcji nasion rzepaku, koszty produkcji oleju rzepakowego oraz ogólne koszty produkcji. Koszty produkcji obliczono w skali roku i uwzględniono dochód ze sprzedaży produktów ubocznych. Badania przeprowadzono w gospodarstwie rolnym na Dolnym Śląsku o powierzchni 100 ha. Wyprodukowane estry mieszane były z olejem napędowym i powstał w ten sposób biodiesel B80. Zawierał on 20% ON i 80% estrów. Wyprodukowanie 1 litra takiego paliwa wyniosło 3,34 zł i było o 1,26 zł niższe od ceny ON w dniu badań. Koszt inwestycji powinien się zwrócić po upływie ośmiu lat.
The purpose of the work was to assess production costs and profitability for rape-seed oil methyl esters using small biodiesel production plant. The subject of the research was a W-400 production plant. The following values were determined in order to specify production profitability for esters: rape seeds production costs, rape-seed oil production costs, and total production costs. Production costs were calculated annually, and the income from the sale of by-products was taken into account. The research was carried out in a Lower Silesian farm, the area of 100 ha. Produced esters were mixed with diesel oil, and thus biodiesel B80 was created. It contained 20% of diesel oil and 80% of esters. Production cost for 1 litre of this fuel was PLN 3.34 and was PLN 1.26 lower than diesel oil price on the day of tests. Investment cost should be returned after eight years.
Źródło:
Inżynieria Rolnicza; 2010, R. 14, nr 1, 1; 63-71
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wzorce odpowiedzi dielektrycznej w dziedzinie częstotliwości izolacji celulozowej o różnym zawilgoceniu syconej estrem syntetycznym
Frequency dielectric response patterns of ester-impregnated cellulose insulation of various moisture content
Autorzy:
Gielniak, J.
Graczkowski, A.
Morańda, H.
Przybyłek, P.
Walczak, K.
Powiązania:
https://bibliotekanauki.pl/articles/159696.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
ester syntetyczny
wzorce zawilgocenia
metoda FDS
synthetic ester
dielectric response patterns
FDS Method
Opis:
W większości transformatorów stosowany jest układ izolacyjny papier-olej mineralny. Do nielicznych wad oleju mineralnego można zaliczyć palność, wybuchowość oraz nieznaczną toksyczność. Alternatywą dla oleju mineralnego są estry syntetyczne lub naturalne. Obecnie największe zastosowanie znajduje ester syntetyczny MIDEL 7131. Jest niepalny i niewybuchowy, wykazuje biodegradowalność i jest nietoksyczny. Transformatory napełniane estrem są szczególnie chętnie stosowane w dużych skupiskach ludzkich oraz w fermach wiatrowych posadowionych w morzu. Zawilgocenie izolacji celulozowej jest jednym z najpoważniejszych problemów eksploatacyjnych transformatorów. Przekroczenie granicznego zawilgocenia celulozy grozi awarią, dlatego konieczne jest okresowe kontrolowanie zawilgocenia. W pracy wykorzystano pośrednią metodę wyznaczania zawilgocenia, opartą na analizie odpowiedzi dielektrycznej w dziedzinie częstotliwości (FDS). Jest to wiarygodna metoda, która nie wymaga pobierania próbek papieru. Wymaga ona jednak wzorców odpowiedzi dielektrycznej dla papieru o różnym zawilgoceniu (charakterystyki przykładowe na rysunkach). Przedmiotem badań są charakterystyki wzorcowe, zdjęte w szerokim zakresie częstotliwości 10-4 – 103 Hz, zawilgocenia 0,5% – 5,0% oraz temperatury 5°C – 50°C.
Most of the transformers are built based on mineral oil–paper insulation system. The few disadvantages of mineral oil may include flammability, explosiveness, and a slight toxicity. The alternative to mineral oil is synthetic or natural ester. Currently widely used is synthetic ester MIDEL 7131. It is non-flammable, non-explosive, non-toxic and biodegradable insulating liquid. Ester-filled transformers are often used for large agglomerations and offshore wind farms. Moisture content of cellulose insulation is one of the most serious operational transformer problems. Moisture content of insulation should be periodically inspected because its high level can lead to transformer failure. In this work the dielectric response in frequency domain was used to determine moisture level of ester-impregnated cellulose. It is a reliable method that does not require sampling of the paper, however, the dielectric response patterns for paper of varying moisture (example curves are shown in Fig.) are needed. The research consist of measurements of dielectric response in wide range of frequency (10-4 – 103 Hz), moisture content (0,5% – 5%) and temperature (5°C – 50°C).
Źródło:
Prace Instytutu Elektrotechniki; 2012, 259; 19-22
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis and in vitro antimicrobial evaluation of some new chalcones containing vinyl ester group and substituted alkyl chain
Autorzy:
Sharma, Vinay S.
Patel, R. B.
Powiązania:
https://bibliotekanauki.pl/articles/1191249.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Antibacterial
Antifungal
Chalcone
Vinyl ester
Opis:
A novel series of chalconyl vinyl ester based derivatives were designed and synthesized. The newly synthesized compounds were studied for efficacy against several bacteria (E.Coli, P.Aeruginosa, S.Aureus, S.Pyogenus) and fungi (C.Albicans, A.Niger, Clavatus) using the broth dilution technique. Chalcones were prepared by treatment of 4-iodo acetophenone with 4-hydroxy benzaldehyde by Claisen-Schimidt condensation reaction. Various chalconyl vinyl ester derivatives (C1-C8) were prepared by reaction of chalcone with 4-n-alkoxy cinnamic acids derivatives. Compound C8 shows the best bioactive desired antibacterial analogue with less MIC value against different tested strains. All the final synthesized compounds were characterized by IR, 1H NMR, and elemental analysis.
Źródło:
World Scientific News; 2016, 54; 240-251
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal properties of natural ester and low viscosity natural ester in the aspect of the reliable operation of the transformer cooling system
Właściwości cieplne estru naturalnego i estru naturalnego o obniżonej lepkości w aspekcie niezawodności działania układu chłodzenia transformatora
Autorzy:
Dombek, Grzegorz
Nadolny, Zbigniew
Marcinkowska, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/301946.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
natural ester
dielectrics
power transformer
thermal properties
ester naturalny
dielektryki
transformator
właściwości cieplne
Opis:
The paper presents the results of comparative studies of thermal properties of various types of natural esters used as electroinsulating liquids in transformers. Adequate thermal properties of electro-insulating liquids ensure reliable work of transformers. Two natural esters were selected for the study – one commonly used in distribution transformers, the other characterized by low viscosity. Fourier Transform Infrared Spectroscopy and UV-Visible spectroscopy were used to examine the chemical structure of the examined esters. Properties such as thermal conductivity coefficient λ, kinematic viscosity υ, specific heat cp, density ρ, and thermal expansion coefficient β were analyzed. Heat transfer factor α of the liquid was calculated on the basis of obtained properties. This factor defines the ability of an insulating liquid to heat transport in the transformer, thus determining its reliability. The authors put forward a thesis that a low viscosity natural ester will have a higher heat transfer factor α due to its low viscosity, which affects the factor α. The analysis of thermal properties was carried out for the following temperatures: 25, 40, 60, and 80°C. On the basis of the calculated factor α, the temperature drops in the transformer filled with the analyzed types of natural esters were determined. It has been shown that if a low viscosity natural ester is used in the cooling system of the transformer, the temperature of the hot-spot will be lower. This fact may contribute to more reliable work of transformers and extend its service life.
W pracy przedstawiono wyniki badań porównawczych właściwości cieplnych różnego rodzaju estrów naturalnych stosowanych jako ciecze elektroizolacyjne w transformatorach. Odpowiednie właściwości cieplne cieczy elektroizolacyjnych zapewniają niezawodną pracę transformatorów. Do badań wybrano dwa estry naturalne – jeden powszechnie stosowany w transformatorach rozdzielczych, drugi charakteryzujący się obniżoną lepkością. Do analizy struktury chemicznej badanych estrów wykorzystano spektroskopię w podczerwieni z transformatą Fouriera (FT-IR) oraz spektroskopię w ultrafiolecie i świetle widzialnym (UV-VIS). Analizowanymi właściwościami cieczy były przewodność cieplna λ, lepkość kinematyczna υ, ciepło właściwe cp, gęstość ρ oraz rozszerzalność cieplna β. Na podstawie przedstawionych właściwości cieplnych obliczono współczynnik przejmowania ciepła α. Współczynnik ten określa zdolność cieczy elektroizolacyjnej do transportu ciepła w transformatorze, a tym samym określa jego niezawodność. Autorzy postawili tezę, że ester naturalny o obniżonej lepkości będzie miał wyższy współczynnik przejmowania ciepła α ze względu na jego obniżoną lepkość. Analizę właściwości cieplnych przeprowadzono dla czterech wartości temperatury: 25, 40, 60 i 80°C. Na podstawie obliczonego współczynnika α określono spadki temperatury w transformatorze wypełnionym analizowanymi estrami naturalnymi. Wykazano, że jeżeli w układzie chłodzenia transformatora stosowany jest ester naturalny o obniżonej lepkości, wówczas temperatura najgorętszego miejsca (ang. hot spot) będzie niższa. Fakt ten może przyczynić się do zwiększenia niezawodności pracy transformatorów i przedłużyć okres ich eksploatacji.
Źródło:
Eksploatacja i Niezawodność; 2019, 21, 3; 384-391
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of a molecular sieve for drying the insulation system of a power transformer in terms of improving its perational reliability
Autorzy:
Cybulski, Mateusz
Przybyłek, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2172034.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
power transformer
insulation system
drying
molecular sieve
mineral oil
natural ester
synthetic ester
Opis:
The first research objective was the assessment of the selectivity of water and hydrogen adsorption by the 3A molecular sieve (MS) in the terms of the safety of using the DGA (Dissolved Gas Analysis) method as a diagnostic technique. The second objective was to demonstrate the efficiency of drying the insulation system consisting of cellulose insulation impregnated with various insulating liquids in terms of improving safety and extending the service life of power transformers. In order to achieve the assumed objectives, measurement systems were prepared and material tests were carried out, based mainly on chromatographic analyzes and measurements of water content using the Karl Fischer titration method. On the basis of the obtained test results and the conducted physical analyzes, the selectivity of MS sorption was shown and it was explained that the facilitator of the adsorption of water molecules is their polar nature related to their large dipole moment. The high efficiency of drying cellulose insulation impregnated with various insulating liquids using MS was also demonstrated.
Źródło:
Eksploatacja i Niezawodność; 2022, 24, 3; 502--509
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ temperatury na wyładowania niezupełne w układzie uwarstwionym w oleju mineralnym oraz estrze syntetycznym
Dependence of temperature on partial discharges activity in synthetic ester-paper setup vs. oil-paper setup
Autorzy:
Malinowski, G.
Powiązania:
https://bibliotekanauki.pl/articles/378017.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
wyładowania niezupełne
ester syntetyczny
olej mineralny
układ izolacyjny papier-ester
układ izolacyjny papier-olej
Opis:
Artykuł przedstawia wyniki badań wyładowań niezupełnych w układzie izolacyjnym papier-ester w odniesieniu do układu izolacyjnego papier-olej, dla trzech wartości temperatury (25°C, 30°C oraz 40°C). W publikacji przedstawiono obiekt badań, procedurę pomiarową oraz analizę wyników. Wyniki badań wskazują na korelację pomiędzy aktywnością wyładowań niezupełnych a temperaturą układu izolacyjnego. Ponadto, badania wskazują, że układ izolacyjny z estrem syntetycznym jest bardziej podatny na wyładowania niezupełne niż układ izolacyjny z olejem mineralnym.
Paper presents results of PD’s investigations in synthetic ester-paper insulating setup vs. oil-paper insulated setup for three values of temperature (25°C, 30°C and 40°C). This article shows the test setup, measuring procedure and analysis of its results. Results show correlation between PD’s activity and temperature of insulating setup. Results show also, that the synthetic ester-paper setup is more susceptible for PD’s than the oilpaper insulating setup.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 82; 151-157
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Concentration analysis of gases formed in mineral oil, natural ester, and synthetic ester by discharges of high energy
Analiza stężeń gazów powstających na skutek oddziaływania łuku elektrycznego na olej mineralny oraz estry naturalne i syntetyczny
Autorzy:
Przybyłek, P.
Gielniak, J.
Powiązania:
https://bibliotekanauki.pl/articles/1365328.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
transformer
diagnostics
mineral oil
natural ester
synthetic ester
electric arc
discharge of high energy
gases
gas chromatography
transformator
diagnostyka
olej mineralny
ester naturalny
ester syntetyczny
łuk elektryczny
wyładowania zupełne
gazy
chromatografia gazowa
Opis:
The paper describes physical foundations of gases generation in different electroinsulating liquids. The authors reviewed literature concerning the analysis of gases generated in these liquids as a result of discharges of low energy. The main purpose of the research was to compare gases formed in mineral oil, natural ester, and synthetic ester resulting from discharges of high energy, which has not been studied so far. The comparison was done both in terms of gases composition and their concentration. The purpose of the research was to give an answer to the question: which of the analysed liquids ensure higher operation safety if there is a discharge of high energy in the insulating system.
W pracy opisano podstawy fizyczne związane z powstawaniem gazów w różnych cieczach elektroizolacyjnych. Dokonano przeglądu literatury dotyczącego analizy gazów generowanych w tych cieczach w wyniku wyładowań zupełnych. Głównym celem badań było porównanie gazów powstających w oleju mineralnym, estrze naturalnym oraz estrze syntetycznym w wyniku oddziaływania na te ciecze wyładowań zupełnych o bardzo dużej energii, co dotychczas nie było przedmiotem badań. Porównania dokonano zarówno pod kątem składu gazów jak i ich stężenia. Wyniki badań miały przede wszystkim dać odpowiedź na pytanie: która z analizowanych cieczy charakteryzuje się większym bezpieczeństwem eksploatacji w sytuacji wystąpienia w układzie izolacyjnym wysokoenergetycznego wyładowania zupełnego.
Źródło:
Eksploatacja i Niezawodność; 2018, 20, 3; 435-442
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Autorski układ do pomiaru współczynnika przejmowania ciepła cieczy elektroizolacyjnych
Authorial system for measuring of heat transfer coefficient of the insulating liquids
Autorzy:
Gościński, P.
Dombek, G.
Nadolny, Z.
Bródka, B.
Powiązania:
https://bibliotekanauki.pl/articles/376465.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
współczynnik przejmowania ciepła α
transformator
pole temperaturowe transformatora
ester naturalny
ester syntetyczny
olej mineralny
Opis:
W artykule opisano autorski układ do pomiaru współczynnika przejmowania ciepła α cieczy elektroizolacyjnych. W pierwszym rozdziale uzasadniono wybór tematyki artykułu oraz pracy naukowej. W kolejnym rozdziale opisano ogólną zasadę pomiaru współczynnika przejmowania ciepła α cieczy elektroizolacyjnych oraz przedstawiono ogólną koncepcję układu pomiarowego. W rozdziale trzecim przedstawiono pierwsze wstępne wyniki testowe układu, które porównano z danymi literaturowymi. Artykuł został zakończony podsumowaniem.
This paper presents a authorial system for measuring heat transfer coefficient α of the insulating liquids. In the first chapter, the choice of subject matter of article and research work were presented. In the following chapter, the general principles for measuring of heat transfer coefficient of the insulating liquids and the conception of measuring system were shown. In the third chapter, the first testing results of the measuring system were presented, later the authors compared them to literature data. Article ends with summary.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 90; 11-19
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fame oxidation and thermal stability
Stabilność termiczna i oksydacyjna FAME
Autorzy:
Łukasik, Z.
Łenyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/256246.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
ester metylowy
kwasy tłuszczowe
biodiesel
antyutleniacz
okres indukcyjny
fatty acids
methyl ester
antioxidant
induction period
Opis:
The paper presents the results of determination of FAME oxidation stability untreated and treated with antioxidant additives. The results show that PN-EN 14112 (Rancimat method) which is required for produces of FAME applied as engine fuel does not allow to distinguish the additives effectiveness a concentration level of 500 mg/kg selected by the authors. Differential results were received when the same samples were tested according to ASTM D 525 (oxidative bomb method), which is based, as is the Rancimat method, on the calculation of induction period. These results were proved by changes of peroxides and acid numbers of FAME after the ASTM D 525 test. 2,6-Di-tert.butyl-4-methylphenol was the most effective of all the tested additives.
W artykule przedstawiono wyniki badania stabilności oksydacyjnej estrów metylowych kwasów tłuszczowych, nieuszlachetnionych i z dodatkami przeciwutleniającymi. Wyniki badań wskazują, że metoda PN-EN 14112 (metoda Rancimat), która jest wymagana dla FAME jako paliwa silnikowego, nie pozwala na rozróżnienie efektywności działania zastosowanych dodatków przy wybranym przez autorów stężeniu 500 mg/kg. Natomiast metoda ASTM D 525 (metoda z bombą utleniającą), która tak jak metoda Rancimat również oparta jest na obliczeniu okresu indukcyjnego, pozwala na rozróżnienie efektywności tych samych dodatków przeciwutleniających, co zostało potwierdzone wynikami zmian liczb nadtlenkowych i kwasowych FAME po teście ASTM D 525. Spośród wszystkich badanych dodatków najbardziej skuteczny okazał się: 2,6-Di-tert.butyl-4-metylfenol.
Źródło:
Problemy Eksploatacji; 2009, 2; 149-158
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of biodiesel fuel on the basis of rape oil and isopropyl alcohol
Ocena wlasciwosci eksploatacyjnych paliwa oleju napedowego bio na podstawie oleju rzepakowego i alkoholu izopropylowego
Autorzy:
Zaharchuk, V.
Tkachuk, V.
Zaharchuk, O.
Powiązania:
https://bibliotekanauki.pl/articles/791924.pdf
Data publikacji:
2011
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
biodiesel fuel
diesel engine
toxicity
isopropyl ester
methyl ester
rapeseed oil
diesel fuel
operating property
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2011, 11
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations on the synthesis and properties of biodegradable poly(ester-carbonate-urea-urethane)s
Autorzy:
Mazurek, M. M.
Rokicki, G.
Powiązania:
https://bibliotekanauki.pl/articles/779133.pdf
Data publikacji:
2013
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
polyurethane
oligo(ester-carbonate) diol
biodegradation
Opis:
A new method of the synthesis of oligo(tetramethylene succinate-co-carbonate) diols using dimethyl succinate, 1,4-butanediol and tetramethylene bis(methyl carbonate) was elaborated. The resultant oligomerols (Mn = 2600- 3700) were characterized by FTIR, 1H NMR, GPC and DSC analysis. Depending on the content of carbonate units in the polymer molecules, the melting point of the crystalline phase changes significantly. The synthesis of poly(ester-carbonate-urea-urethane)s was carried out with two aliphatic diisocyanates - cyclic IPDI or linear HDI. The resultant products exhibited very good mechanical properties - tensile strength up to 60 MPa and elongation at break about 500%. Preliminary studies confirmed that the presence of ester units in the soft segments as well as lack of crystalline phase significantly enhances the biodegradability of the PUR in comparison to that of polyurethanes based on carbonate oligomers.
Źródło:
Polish Journal of Chemical Technology; 2013, 15, 4; 80-88
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany odpowiedzi dielektrycznej preszpanu syconego olejem mineralnym po wymianie cieczy izolacyjnej na ester syntetyczny
Dielectric response change of pressboard saturated with mineral oil after replacing insulating liquid with synthetic ester
Autorzy:
Fatyga, P.
Powiązania:
https://bibliotekanauki.pl/articles/377537.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
odpowiedź dielektryczna
olej mineralny
ester syntetyczny
Opis:
Jedną z metod oceny zawilgocenia izolacji stałej transformatorów energetycznych jest metoda FDS. Bazuje ona na wzorcach odpowiedzi dielektrycznej układu izolacyjnego o znanych parametrach. Konsekwencją wymiany cieczy izolacyjnej z oleju mineralnego na ester syntetyczny są duże problemy interpretacyjne zmierzonej odpowiedzi dielektrycznej transformatora w kontekście oceny zawilgocenia jego izolacji stałej. Artykuł prezentuje wyniki badań modelowych odpowiedzi dielektrycznej próbek preszpanu wysyconego olejem mineralnym, który następnie wymieniono na ester syntetyczny.
One of the methods to estimate the power transformers solid insulation moisture is frequency domain spectroscopy (FDS). FDS is based on the patterns of dielectric insulation system’s responses. The consequence of the insulating liquid exchange (from mineral oil to synthetic ester) are enormous interpretation problems of the measured transformers dielectric response in the context of solid isolation moisture estimating. The article presents the results of model responses of the dielectric pressboard sample filled with mineral oil which is afterwards changed for synthetic ester.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 86; 333-340
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamika wymiany oleju mineralnego na ester syntetyczny w izolacji celulozowej transformatora
The dynamics of exchange of mineral oil to synthetic ester in cellulose insulation of transformer
Autorzy:
Fatyga, P.
Powiązania:
https://bibliotekanauki.pl/articles/378105.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
odpowiedź dielektryczna
olej mineralny
ester syntetyczny
Opis:
Wymiana całości oleju mineralnego na ester syntetyczny w transformatorze jest technicznie niewykonalna, gdyż w kadzi transformatora zawsze pozostanie pewna ilość oleju mineralnego. W tej sytuacji ocena stopnia zawilgocenia izolacji stałej transformatora z użyciem metody FDS jest obciążona pewnym błędem. Błąd ten można skorygować ale wyznaczane współczynniki poprawkowe będą miały zastosowanie dopiero po osiągnięciu w transformatorze stanu równowagi, co wymaga pewnego czasu. Artykuł prezentuje wstępne wyniki badań oszacowania czasu przesycenia izolacji celulozowej mieszaniną nowej cieczy i pozostałości oleju mineralnego.
Replacing the whole mineral oil with synthetic ester in the transformer is technically impossible, because in the tank of the transformer will always remain a small amount of mineral oil. In this situation, the determination of the moisture degree in transformer solid insulation using the FDS method is performed with systematic error. The error can be corrected but determined coefficient factors will can be applied only after reaching equilibrium state in a transformer, that requires some time. The article presents the preliminary results of the research, whose purpose is estimation the time required for saturation of cellulose insulation with mixture consist of a new liquid and residual mineral oil.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 90; 325-332
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies