Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "energy analysis" wg kryterium: Temat


Tytuł:
Study of Noise Propagation for Small Vessels
Autorzy:
Weryk, M.
Kozaczka, E.
Grelowska, G.
Powiązania:
https://bibliotekanauki.pl/articles/177515.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ship noise
noise analysis
statistical energy analysis
Opis:
The paper presents the results of the noise propagation analysis in ship structures tested in a number of AHTS (Anchor Handling Tug Supply) vessels. Statistical Energy Analysis (SEA) based on numerical model developed specially for the purpose of this numerical investigation were conducted. This numerical model enabled the analysis of both the structural elements and the acoustic spaces. For the detailed studies 47 points fixed at various ship locations were selected. Prediction results with use of the numerical model were compared with the experimental results carried out in six identical AHTS vessels. Experimental studies were performed in accordance with the requirements of the International Maritime Organization (IMO) Resolution A.468 (XII). As a result one presented a comparison of the model analysis and experimental tests results.
Źródło:
Archives of Acoustics; 2015, 40, 2; 267-272
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy and economic analysis of the use of photovoltaic in energy systems
Autorzy:
Szczerbowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/97295.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
photovoltaic
renevable energy sources
energy analysis
economic analysis
simulation modelling
Opis:
Energy policy of Poland in a balanced way has to provide security of energy supply, increase the use of its own resources and promote the sustainable development of different electricity generation technologies. The established aims of climate and energy policy will be difficult to achieve without efficient technologies based on distributed generation. In this context, the importance of the development and use of photovoltaic systems is growing. Photovoltaics is one of the most promising technologies and the possibilities of its use in various scale energy systems make it an effective and safe source of energy and an important part of a stable and independent energy mix in the future.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 416-422
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An experimental study of solar air heater using arc shaped wire rib roughness based on energy and exergy analysis
Autorzy:
Ghritlahre, Harish Kumar
Powiązania:
https://bibliotekanauki.pl/articles/1955008.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
artificial roughness
energy analysis
exergy analysis
solar air heater
Opis:
In the present study, energy and exergy analysis has been evaluated for roughened solar air heater (SAH) using arc shaped wire ribs. To achieve this aim, two different types of flow arrangement have been considered. These arrangements are: apex upstream flow and apex downstream flo. In addition to this, a smooth duct SAH has been used for comparative study. The experiments were performed using the mass flow rate of 0.007– 0.022 kg/s on outdoor condition at Jamshedpur city of India. The absorber plate roughness geometry has been designed with relative roughness height 0.0395, rib size 2.5 mm, relative roughness pitch 10 and arc angle 60◦ . The energetic and exergetic performances have been examined on the basis of the first and second law of thermodynamics. According to the results, there is observed to be the maximum thermal efficiency and exergy efficiency as 73.2% and 2.64%, respectively, for apex upstream flow SAH at 0.022 kg/s, while, at same mass flow rate the maximum thermal efficiency and exergy efficiency is obtained as 69.4% and 1.89%, respectively, for apex downstream flow SAH. In addition to this, results reported that the maximum outlet temperature and temperature difference observed at lower mass flow rate. Also examined the outlet air temperature of SAH with various mass flow rates is very important for both analysis.
Źródło:
Archives of Thermodynamics; 2021, 42, 3; 115-139
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance of a combined cycle power plant due to auxiliary heating from the combustion chamber of the gas turbine topping cycle
Autorzy:
Khan, Mohammad Nadeem
Powiązania:
https://bibliotekanauki.pl/articles/1845501.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pressure ratio
air-fuel ratio
supplement heating
exergy analysis
energy analysis
Opis:
Energy demand is increasing exponentially in the last decade. To meet such demand there is an urgent need to enhance the power generation capacity of the electrical power generation system worldwide. A combined-cycle gas turbines power plant is an alternative to replace the existing steam/gas electric power plants. The present study is an attempt to investigate the effect of different parameters to optimize the performance of the combined cycle power plant. The input physical parameters such as pressure ratio, air fuel ratio and a fraction of combustible product to heat recovery heat exchanger via gas turbine were varied to determine the work output, thermal efficiency, and exergy destruction. The result of the present study shows that for maximum work output, thermal efficiency as well as total exergy destruction, extraction of combustible gases from the passage of the combustion chamber and gas turbine for heat recovery steam generator is not favorable. Work output and thermal efficiency increase with an increase in pressure ratio and decrease in air fuel ratio but for minimum total exergy destruction, the pressure ratio should be minimum and air fuel ratio should be maximum.
Źródło:
Archives of Thermodynamics; 2021, 42, 1; 147-162
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza energetyczna pracy układu instalacja fotowoltaiczna–elektrolizer przeznaczonego do produkcji wodoru
Energy analysis of the system PV–electrolyser designed for the production of hydrogen
Autorzy:
Ceran, Bartosz
Powiązania:
https://bibliotekanauki.pl/articles/2142997.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
wodór
elektrolizer PEM
analiza energetyczna
straty energii
hydrogen
PEM electrolyser
energy analysis
energy losses
Opis:
W publikacji przedstawiono wyniki analizy energetycznej układu farma fotowoltaiczna – elektrolizer do produkcji czystego, zielonego wodoru. Analizę przeprowadzono dla okresu 10-letniej eksploatacji systemu z uwzględnieniem wpływu spadku wydajności urządzeń na efektywność energetyczną procesu produkcji wodoru. Zdefiniowano równania bilansowe systemu. Na podstawie produkcji energii elektrycznej przez instalacje PV dobrano liczbę pracujących elektrolizerów. Przedstawiono wpływ starzenia się paneli PV na charakterystykę eksploatacyjną PPV = f(E). Opisano model matematyczny przeznaczono do wyznaczania spadku wydajności elektrolizera na podstawie wzrostu wartości napięcia średniego Uav. Wyznaczono zmiany wartości wskaźnika jednostkowego kosztu produkcji wodoru oraz zmiany wartości wskaźnika jednostkowego zapotrzebowania na energię do produkcji 1 kg wodoru. Uzyskane wyniki zaprezentowano w formie graficznej za pomocą wykresów słupkowych. W pracy zwrócono uwagę na fakt, że nieuwzględnianie spadku wydajności urządzeń prowadzi do uzyskania błędnych wyników dotyczących prognozowanej ilości produkowanego wodoru. Wykazano konieczność prowadzania analiz techniczno-ekonomicznych pracy rozpatrywanego systemu w perspektywie długoterminowej.
Źródło:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN; 2022, 110; 119--128
2080-0819
Pojawia się w:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of energy consumption of a hybrid vehicle in real-world conditions
Autorzy:
Mamala, Jarosław
Graba, Mariusz
Bieniek, Andrzej
Prażnowski, Krzysztof
Augustynowicz, Andrzej
Śmieja, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2038048.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
energy consumption
hybrid vehicle
road tests
energy share analysis
Opis:
The paper presents an analysis of energy consumption in a Plug-in Hybrid Electric Vehicle (PHEV) used in actual road conditions. Therefore, the paper features a comparison of the consumption of energy obtained from fuel and from energy taken from the vehicle’s batteries for each travel with a total distance of 5000 km. The instantaneous energy consumption per travelling kilometre in actual operating conditions for a combustion engine mode are within the range of 233 to 1170 Wh/km and for an electric motor mode are within the range of 135 to 420 Wh/km. The average values amount to 894 Wh/km for the combustion engine and 208 Wh/km for the electric motor. The experimental data was used to develop curves for the total energy consumption per 100km of road section travelled divided into particular engine types (combustion/electric), demonstrating a close correlation to actual operating conditions. These values were referred to the tested passenger vehicle’s approval data in a WLTP test, with the average values of 303 Wh/km and CO2 emission of 23 g/km.
Źródło:
Eksploatacja i Niezawodność; 2021, 23, 4; 636-645
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on the Effectiveness of Monte Carlo Filtering when Correcting Negative SEA Loss Factors
Autorzy:
Nieradka, Paweł
Dobrucki, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/31339865.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
statistical energy analysis
coupling loss factor
Monte Carlo filtering
power injection method
Opis:
The power injection method (PIM) is an experimental method used to identify the statistical energy analysis (SEA) parameters (called loss factors – LFs) of a vibroacoustic system. By definition, LFs are positive real numbers. However, it is not uncommon to obtain negative LFs during experiments, which is considered a measurement error. To date, a recently proposed method, called Monte Carlo filtering (MCF), of correcting negative coupling loss factors (CLFs) has been validated for systems that meet SEA assumptions. In this article, MCF was validated for point connections and in conditions where SEA assumptions are not met (systems with low modal overlap, non-conservative junctions, strong coupling). The effect of removing MCF bias on the results was also examined. During the experiments, it was observed that the bias is inversely proportional to the damping loss factor of the examined subsystems. The obtained results confirm that the PIM, combined with MCF, allows to determine non-negative SEA parameters in all considered cases.
Źródło:
Archives of Acoustics; 2023, 48, 3; 201-218
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oddziaływanie drgań miejscowych na organizm ludzki - ocena analizy dynamicznej i energetycznej
Influence of local vibrations on a human body - assessment of daynamical and energy analyses
Autorzy:
Dobry, M. W.
Wojsznis, M.
Powiązania:
https://bibliotekanauki.pl/articles/328672.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
analiza dynamiczna
analiza energetyczna
zespół wibracyjny
dynamical analysis
energy analysis
Vibration induced White Finger disease
Opis:
W pracy zaprezentowano analizę dynamiczną i energetyczną systemu człowiek- zmechanizowane narzędzie ręczne. Przedstawione przebiegi mocy chwilowej sprężystości pozwoliły określić miejsca największej koncentracji przepływu energii w badanym systemie. Wyniki analizy energetycznej zgadzają się z danymi medycznymi zebranymi dla osób pozostających pod długotrwałym wpływem drgań mechanicznych generowanych przez pracujące narzędzia. Analiza dynamiczna przeprowadzana w dziedzinie amplitud przyspieszeń drgań, jako wielkości kryterialnej, wykazała rozbieżności tej oceny. Analiza energetyczna wykazała zatem zgodność oceny wpływu drgań na organizm człowieka ze skutkami szkodliwego oddziaływania drgań wykazanymi w raportach medycznych w postaci uszkodzeń stawów kończyn górnych.
The paper presents dynamical and energy analyses of a human - power hand-held tool system. The presented characteristics of instantaneous power of elasticity allowed defining points with the highest concentration of energy flow in the investigated system. The results of energy analysis are coherent with medical data gathered from people who had been exposed to vibrations generated by working tools for a very long time. The dynamical analysis in the domain of vibration acceleration amplitudes showed divergence in the evaluation. Hence, the energy analysis showed consistence in the assessment of influence of vibrations on a human body with the effects of damaging influence of vibrations showed in medical reports as damage to upper limb joints.
Źródło:
Diagnostyka; 2004, 30, T. 1; 151-154
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative Analysis of the Production Process of a Flange-Type Product by the Hybrid and Traditional Method with the Use of Simulation Methods
Autorzy:
Terelak-Tymczyna, Agnieszka
Bachtiak-Radka, Emilia
Jardzioch, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/2067547.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
machining
hybrid machining
VSM
SLM
process simulation
cost of the production
energy analysis
Opis:
In the era of Industry 4.0, the digitization of production processes is one of the important elements contributing to the reduction of uncertainty related to the implementation of new production methods. The worldwide epidemic situation and its constraints have resulted in supply chain continuity problems. These problems make enterprises look for the possibility of producing products that they need at the moment and which they cannot obtain from the market. In special cases, this may also apply to spare parts necessary to maintain the continuity of production. The main reason for research on comparing production processes is meeting the challenges related to the pandemic situation and problems in maintaining timeliness, flexibility, and continuity of the supply chain. The first stage of the research was to visualize the course of the process and determine the lead times for both production methods. For further analysis, a digital process model was used to compare the hybrid and the classical method to check the viability of the interchangeability of methods for the production process of the flange part. The interchangeability of production methods was dictated by problems related to the supply of components for the execution of orders. The article simulates the model for unit and small-lot production in batches of 10 and 100 pieces, considering such aspects as: order completion time, energy consumption of the process, production costs, taking into account the classic and hybrid methods. The conducted research was aimed at determining the profitability of the production of flange-type products by means of classical processing and hybrid and checking the interchangeability of production methods in accordance with quality requirements as well as reducing uncertainty with the implementation of new production systems in changing market conditions. The simulations show that the use of hybrid production is recommended for unit production. In the case of small-lot production, already with 10 items, production in the traditional process is 21% cheaper, and for the production of 100 items, the cost of traditional production is reduced by 33% compared to hybrid production.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 1; 231--242
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Renewable energy in planning of sustainable urban units, is energy autarky possible in nZEB buildings?
Autorzy:
Oniszk-Popławska, A.
Ryńska, E. D.
Powiązania:
https://bibliotekanauki.pl/articles/105714.pdf
Data publikacji:
2016
Wydawca:
Centrum Badań i Innowacji Pro-Akademia
Tematy:
energy autarky
nearly zero-energy building
nZEB
renewable energy
urban unit energy analysis
autarkia energii
budynek niemal zeroenergetyczny
energia odnawialna
Opis:
Energy autarky is a concept commonly used in the context the of power off-grid or remote island systems. However, it has rarely reflected the idea of self-sufficiency of urban units, especially in cities with access to external technical infrastructures such as power and district heating networks. Energy autarky can also be considered auxiliary to nZEB calculation procedures, as an energy demand-supply balancing approach for calculating renewable energy shares. In fact, in Central and Eastern Europe for existing urban tissues buildings' self-sufficiency would be difficult to achieve due to a dominating role of space heating in energy demand shares. Proportions can, however, change in nZEB (nearly zero energy) buildings, with increasing importance and shares of electricity in the final energy consumption and a decreasing role of space heat. In this article a new approach to planning of energy (electricity) autarky at the level of an urban unit is presented, taking into account new nZEB standards at the same time. This is supposed to serve as a voice in the discourse on the formulation of future methodologies.
Źródło:
Acta Innovations; 2016, 18; 49-57
2300-5599
Pojawia się w:
Acta Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie wartości czasu wykorzystania mocy zainstalowanej elektrolizera zasilanego z farmy fotowoltaicznej
Determination of the value of the time of using the installed power of the electrolyser supplied from the photovoltaic farm
Autorzy:
Ceran, Bartosz
Wróblewski, Robert
Powiązania:
https://bibliotekanauki.pl/articles/2204800.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
wodór
elektrolizer PEM
analiza energetyczna
bateria elektrochemiczna
hydrogen
PEM electrolyser
energy analysis
electrochemical battery
Opis:
W rozdziale przedstawiono przykłady inwestycji w technologie wodorowe w Polsce. Przedstawiono wyniki analizy energetycznej układu farma fotowoltaiczna–elektrolizer do produkcji czystego, zielonego wodoru. Zdefiniowano wzór na czas wykorzystania mocy zainstalowanej elektrolizera zasilanego z farmy PV oraz wyznaczono jego wartość. Przedstawiono profil produkcji energii elektrycznej przez farmę PV. Obliczenia wykonano na podstawie danych nasłonecznienia dla lokalizacji miasta Poznania. Przytoczono wzór na wartość mocy generowanej przez farmę PV oraz wzory pozwalające określić roczną wartość masy wyprodukowanego wodoru. Przebadano wpływ wartości stosunku mocy elektrolizera do mocy farmy fotowoltaicznej (PEL/PPV) na wartość czasu wykorzystania jego mocy zainstalowanej. Wyniki analizy przedstawiono w formie graficznej za pomocą charakterystyki PEL/PPV = f(TEL). Zaproponowano metodologię doboru mocy i pojemności baterii elektrochemicznej w celu zwiększenia produkcji wodoru.
The chapter presents examples of investments in hydrogen technologies in Poland. The results of the energy analysis of the photovoltaic farm-electrolyser system for the production of pure, green hydrogen are presented. The formula for the use of the installed power of the electrolyser supplied from a PV farm was defined and its value was determined. The profile of electricity production by a PV farm was presented. The calculations were made on the basis of insolation data for the city of Poznań. The formula for the value of the power generated by the PV farm and the formulas allowing to determine the annual value of the mass of produced hydrogen were presented. The influence of the ratio of the electrolyser power to the power of a photovoltaic farm (PEL/PPV) on the value of the utilization time of its installed power was investigated. The results of the analysis are presented graphically by means of the PEL/PPV = f(TEL) characteristic. A methodology for selecting the power and capacity of an electrochemical battery was proposed to increase hydrogen production.
Źródło:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN; 2023, 111; 131--142
2080-0819
Pojawia się w:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie izolacyjności akustycznej przegród Metodą Statystycznej Analizy Energii
Application of Statistical Energy Analysis Method for modelling sound insulation of baffles
Autorzy:
Kosała, K.
Majkut, L.
Olszewski, R.
Powiązania:
https://bibliotekanauki.pl/articles/315437.pdf
Data publikacji:
2018
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
izolacyjność akustyczna
modelowanie
Metoda Statystycznej Analizy Energii
sound insulation
modelling
Statistical Energy Analysis Method
Opis:
W artykule przedstawiono oparty na Metodzie Statystycznej Analizy Energii model izolacyjności akustycznej pojedynczych przegród jednorodnych. Porównano wyznaczone charakterystyki częstotliwościowe izolacyjności akustycznej od dźwięków powietrznych przegród modelu obliczeniowego z wynikami badań doświadczalnych. Obliczenia przy wykorzystaniu modelu Metody Statystycznej Analizy Energii oraz badań laboratoryjnych przeprowadzono dla płyt wykonanych z pleksiglasu i akrylu.
The article presents the model of sound insulation of single homogeneous baffles based on the Statistical Method of Energy Analysis. The determined frequency characteristics of airborne sound insulation of the baffles obtained from the calculation model with the results of experimental tests were compared. Calculations using the Statistical Method of Energy Analysis and laboratory tests were performed for plates made of plexiglass and acrylic.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2018, 19, 12; 106-109
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of modern techniques for energy analyses in iraqi buildings
Autorzy:
Hatem, Wadhah Amer
Powiązania:
https://bibliotekanauki.pl/articles/231340.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
modelowanie informacji o budynku
BIM
Ecotect
analiza energetyczna
modelowanie
building information modelling
energy analysis
modelling
Opis:
Most architects and construction engineers need to use modern energy analysis software for the purpose of improving their design. There is software within the BIM (Building Information Modeling) that are specific to energy which help to get the calculations of energy in an easy way. Building energy analysis studies in Iraq are few and limited and insufficient attention is given to this important stage in building design which is one of the necessary and important stages to obtain a good design. In this paper, one of the existing buildings in one of the regions of Iraq was modelled by using BIM modelling software (Autodeck Revit). The energy analysis was then carried out by the (Autodesk Ecotect) software after exporting the previously modelled model. The results obtained are necessary to achieve the best design in terms of energy with the assumption of future changes in buildings that are similar in style and area conditions in order to optimize energy.
Źródło:
Archives of Civil Engineering; 2020, 66, 3; 595-603
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kierunki termomodernizacji
Directions of thermal modernization
Autorzy:
Krause, P.
Steidl, T.
Wojewódka, D.
Powiązania:
https://bibliotekanauki.pl/articles/129108.pdf
Data publikacji:
2015
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
termomodernizacja
analiza energetyczna
straty ciepła
modernizacja budynków
thermal modernization
energy analysis
heat loss
modernization of buildings
Opis:
W świetle zaostrzających się przepisów w zakresie oszczędności energii i izolacyjności cieplnej oraz zbliżającej się daty 31 grudnia 2020, od której w państwach członkowskich UE wszystkie nowo powstające budynki powinny wykazywać „niemal zerowe zapotrzebowanie na energię”, powstaje pytanie o możliwość modernizacji budynków istniejących. Wśród nich liczną grupę stanowią budynki wzniesione w technologii wielkopłytowej.
The directions of thermal modernization will follow the planned changes in law, both local and dictated by the European Union. Looking to the future, an analysis of possible thermal modernization solutions in the next ten years has been carried out by the authors of the article presented.
Źródło:
Builder; 2015, 19, 5; 46-48
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combined cooling, heat and power (Trigeneration) at Offenburg University of Applied Sciences
Autorzy:
Gopisetty, S.
Treffinger, P.
Powiązania:
https://bibliotekanauki.pl/articles/363076.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
control strategy
energy analysis
modes of operation
trigeneration
analiza strategii kontroli
analiza energii
tryby pracy
trójgeneracja
Opis:
The energy supply of Offenburg University of Applied Sciences (HS OG) was changed from separate generation to trigeneration in 2007/2008. Trigeneration was installed for supplying heat, cooling and electrical power at HS OG. In this paper, trigeneration process and its modes of operation along with the layout of the energy facility at HS OG were described. Special emphasis was given to the operation schemes and control strategies of the operation modes: winter mode, transition mode and summer mode. The components used in the energy facility were also outlined. Monitoring and data analysis of the energy system was carried out after the commissioning of trigeneration in the period from 2008 to 2011. Thus, valuable performance data was obtained.
Źródło:
Environmental Biotechnology; 2013, 9, 1; 25-37
1734-4964
Pojawia się w:
Environmental Biotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies