Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "enclosure" wg kryterium: Temat


Tytuł:
CuO–water mhd mixed convection analysis and entropy generation minimization in double-lid–driven u-shaped enclosure with discrete heating
Autorzy:
Mliki, Bouchmel
Miri, Rached
Djebali, Ridha
Abbassi, Mohamed A.
Powiązania:
https://bibliotekanauki.pl/articles/2204647.pdf
Data publikacji:
2023
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
U-shaped enclosure
MHD mixed convection
nanoliquids
double lid-driven cavity
entropy generation
LBM
Opis:
The present study explores magnetic nanoliquid mixed convection in a double lid–driven U-shaped enclosure with discrete heat-ing using the lattice Boltzmann method (LBM) numerical method. The nanoliquid thermal conductivity and viscosity are calculated using the Maxwell and Brinkman models respectively. Nanoliquid magnetohydrodynamics (MHD) and mixed convection are analyzed and entropy generation minimisation has been studied. The presented results for isotherms, stream isolines and entropy generation describe the interaction between the various physical phenomena inherent to the problem including the buoyancy, magnetic and shear forces. The operating parameters’ ranges are: Reynolds number (Re: 1–100), Hartman number (Ha: 0–80), magnetic field inclination (γ: 0°–90°), nanoparticles volume fraction (ϕ: 0–0.04) and inclination angle (α: 0°–90°). It was found that the and the total entropy generation augment by increasing Re, ϕ: and γ. conversely, an opposite effect was obtained by increasing Ha and α. The optimum magnetic field and cavity inclination angles to maximum heat transfer are γ = 90° and α = 0.
Źródło:
Acta Mechanica et Automatica; 2023, 17, 1; 112--123
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Konstrukcja przestrzeni i jej rola w kreacji podmiotu opowiadania „Studnia i wahadło” Edgara Allana Poego
The Construction of Space and Its Role in Creating the Subject of the Short Story “The Pit and the Pendulum” by Edgar Allan Poe
Autorzy:
Iwanicka, Julia
Powiązania:
https://bibliotekanauki.pl/articles/2120295.pdf
Data publikacji:
2022-07-15
Wydawca:
Uniwersytet w Białymstoku. Wydawnictwo Uniwersytetu w Białymstoku
Tematy:
przestrzeń literacka
fokalizacja
zmysły
uwięzienie
doświadczenie
emocje
literary space
senses
enclosure
experience
emotion
Opis:
Celem artykułu jest ukazanie zależności między konstrukcją przestrzeni w Studni i wahadle Edgara Allana Poego a kreacją bohatera opowiadania – więźnia hiszpańskiej Inkwizycji, poddawanego skomplikowanym torturom. Odwołując się do ustaleń z zakresu geopoetyki oraz do koncepcji fokalizacji w ujęciu Mieke Bal i Shlomith Rimmon-Kennan, autorka analizuje wpływ przestrzeni na zmysły i emocje podmiotu w sytuacji deprywacji sensorycznej. Podejmuje także kwestię ważnych w twórczości Poego i widocznych w opowiadaniu wątków, takich jak tafefobia, gotycyzm oraz idee oświeceniowe. W toku analizy dowodzi, że konstrukcja podmiotu w opowiadaniu wynika w głównej mierze ze sposobu, w jaki doświadcza on i opisuje przestrzeń więziennej celi.
The article aims to show the relationship between the construction of space in Edgar Allan Poe's The Pit and the Pendulum and the creation of the story's protagonist – a prisoner of the Spanish Inquisition who suffers elaborate torture. Relying on geopoetics and the concept of focalization as understood by Mieke Bal and Shlomith Rimmon-Kennan, the author analyzes the impact of space on the senses and emotions of the subject in a situation of sensory deprivation. She also addresses various themes, important in Poe's work and evident in the story, such as teraphobia, gothicism and the ideas of Enlightenment. In the course of the analysis, she argues that the way the prisoner experiences and describes the space of the prison cell becomes the focal point for the construction of the literary subject in this short story.
Źródło:
Białostockie Studia Literaturoznawcze; 2022, 20; 239-257
2082-9701
2720-0078
Pojawia się w:
Białostockie Studia Literaturoznawcze
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Natural convection flow in semi-trapezoidal porous enclosure filled with alumina-water nanofluid using Tiwari and Das’ nanofluid model
Autorzy:
Vedavathi, Nallapati
Venkatadri, Kothuru
Fazuruddin, Syed
Raju, G. Sankara Sekhar
Powiązania:
https://bibliotekanauki.pl/articles/38889212.pdf
Data publikacji:
2022
Wydawca:
Instytut Podstawowych Problemów Techniki PAN
Tematy:
natural convection
laminar flow
porous medium
nanofluid
semi-trapezoidal enclosure
Opis:
Nowadays, optimal parameters are necessary for heat transfer enhancement in different practical applications. A numerical simulation of natural convection in a semi-trapezoidal enclosure embedded with porous medium is presented. Stream function and temperature using the Darcy–Boussinesq approximation and Tiwari and Das’ nanofluid model with new more realistic empirical correlations for the physical properties of the nanofluids are formulated. The developed partial differential equations are employed with the help of the stream function approach. The in-house developed computational MATLAB code is validated with the previously published work. The impact of a wide range of governing parameters on fluid flow patterns and temperature gradient variations is presented. The thermal Rayleigh number (Ra) can be a control key parameter for heat and convective flow. Thermal dispersion effects are also examined in this study. An increase in the Rayleigh number leads to an increase in heat transfer, where one can find a reduction of convective heat transfer with φ.
Źródło:
Engineering Transactions; 2022, 70, 4; 303-318
0867-888X
Pojawia się w:
Engineering Transactions
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical study of the ejection cooling mechanism of ventilation for a marine gas turbine enclosure
Autorzy:
Shi, Hong
Zhang, Qianwei
Liu, Meinan
Yang, Kaijie
Yuan, Jie
Powiązania:
https://bibliotekanauki.pl/articles/32908258.pdf
Data publikacji:
2022
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
gas turbine enclosure
ejecting cooling
ventilation
CFD
Opis:
A marine gas turbine enclosure must be designed to prevent overheating of the electrical and engine control components as well as diluting potential fuel leaks. In order to achieve an optimal enclosure design, a numerical study of the ventilation-ejection cooling mechanism of a gas turbine enclosure is carried out in this paper. The evaluation index of the ejection cooling performance is first proposed and the algorithm of numerical simulation is verified. On this basis, orthogonal combinations of structural parameters are carried out for the expansion angle α of the lobed nozzle and the spacing S between the outlet plane of the lobed nozzle and the inlet plane of the mixing tube. The flow and the temperature distribution inside the enclosure are analysed under different operating conditions. The results show that the influence of the lobed nozzle expansion angle α and the spacing S on the performance is not a single-valued function but the two influencing factors are mutually constrained and influenced by each other. For any spacing, the combined coefficient is optimal for the expansion angle α = 30°. When the expansion angle α = 45° and the spacing S = 100 mm, the combined coefficient and the temperature distribution inside the enclosure are optimal at the same time.
Źródło:
Polish Maritime Research; 2022, 3; 119-127
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of solar radiation transmission for polycarbonate retractable swimming pool enclosures
Autorzy:
Zapałowicz, Zbigniew
Garnysz-Rachtan, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1845493.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
outdoor swimming pool
swimming pool roofing system
pool enclosure
polycarbonate enclosure
solar transmission through enclosure
Opis:
Application of retractable enclosures enables to lengthen operation periods for outdoor swimming pools operated in the moderate climate zone. Enclosures allow to diminish energy losses from water in the pool to the environment. Thermal calculations for pools with retractable enclosures are difficult to carry out because of a number of required parameters which can only be estimated. One of them is the transmission of solar radiation through the enclosure. The present paper presents the method of estimation of this parameter for swimming pool enclosures made of polycarbonate panels that have multichannels structure. In order to calculate transmission, the methodology considering the multiples of solar reflection inside the enclosure and their absorption by polycarbonate has been elaborated. Calculation results for transmission of the enclosure were verified experimentally. Analysis of results show that the transmission depends strongly on the enclosure’s construction and on the direction of solar radiation on the enclosure. Mean transmission values of enclosure under research were determined both from calculations and experiment are equal to about 0.69 and 0.64, respectively. However, experimentally determined mean values of total transmission by parallel and perpendicular solar directions in relation to channel axes are equal to about 0.69 and 0.60, respectively.
Źródło:
Archives of Thermodynamics; 2021, 42, 1; 129-146
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obudowy dźwiękochłonno-izolacyjne urządzeń ultradźwiękowych, ograniczające poziom hałasu przenikającego do środowiska. Wyniki badań własnych
Sound-absorbing and insulating enclosures for ultrasonic devices reducing the level of noise penetrating the environment. Own research results
Autorzy:
Mikulski, Witold
Powiązania:
https://bibliotekanauki.pl/articles/2202831.pdf
Data publikacji:
2021
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
obudowy dźwiękochłonno-izolacyjne
izolacyjność akustyczna
hałas ultradźwiękowy
soundproofed enclosure
sound insulating enclosure
sound power insulation
ultrasonic noise
Opis:
W artykule omówiono rozwiązania techniczne obudów dźwiękochłonno-izolacyjnych przeznaczonych do urządzeń będących źródłami hałasu ultradźwiękowego (częstotliwości dźwięku 10-40 kHz). Ze względu na zagrożenie zdrowia pracowników obsługujących technologiczne urządzenia ultradźwiękowe oraz fakt, że znajdują się oni blisko tych urządzeń, konieczne jest zastosowanie skutecznego środka zmniejszającego to zagrożenie, jakim są obudowy dźwiękochłonno-izolacyjne. Dotychczas nie określono jednak ani zasad stosowania takich obudów, ani właściwości dźwiękoizolacyjnych i dźwiękochłonnych ich materiałów w tym zakresie częstotliwości. W artykule zaprezentowano wyniki badań własnych, dotyczących wpływu materiałów, z których są wykonywane obudowy, zastosowanej wyściółki oraz obecności otworów w obudowach na poziom hałasu emitowanego przez urządzenia ultradźwiękowe, który przenika do środowiska.
The article discusses the technical solutions of sound-absorbing and sound-insulating enclosures for devices that are sources of ultrasonic noise (sound frequencies range of 10-40 kHz). Due to the high health risk of employees operating ultrasonic technological devices and the fact that they are in close proximity to these devices, it is necessary to use an effective measure to reduce this risk, i.e. sound-insulating enclosures. So far, however, the rules for the use of such casings and the sound-insulating and sound-absorbing properties of their materials (in this frequency range) have not been defined. The article presents the results of own research on the impact of the materials used to make enclosures, linings of casings and the presence of openings (hole) in casings on the level of noise emitted by ultrasonic devices that penetrates into the environment.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2021, 9; 22-28
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Plan as Social Structure and Section as Emotional Enclosure - a Complementary Pair of Ordering Principles in Contemporary Architecture
Plan jako struktura społeczna i przekrój pionowy jako zamknięcie emocjonalne - uzupełniająca się para zasad porządkowania we współczesnej architekturze
Autorzy:
Kubec, Jan
Powiązania:
https://bibliotekanauki.pl/articles/1848213.pdf
Data publikacji:
2021
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
rysunek architektoniczny
rzut poziomy
struktura społeczna
przekrój pionowy
element emocjonalny
architectural drawing
plan
social structure
section
emotional enclosure
Opis:
The title of the article is a paraphrase of the title of an essay by Wilfried Wang: SiteSpecificity, Skilled Labor, and Culture: Architectural Principles in the Age of Climate Change [9]. While Wang raises the fundamental problem of the need to change the architect's attitude in the design process in a climate crisis, paying particular attention to the need to “reconnect the building with the context”3, the author discusses the very workshop of the architect's work, and more precisely – the basic drawing tools. He puts forward theses about what the title issues should be for architects today.
Tytuł artykułu jest parafrazą tytułu eseju Wilfrieda Wanga: SiteSpecificity, Skilled Labor and Culture: Architectural Principles in the Age of Climate Change [9]. O ile Wang porusza zasadniczy problem potrzeby zmiany postawy architekta w procesie projektowym w sytuacji kryzysu klimatycznego, zwracając uwagę zwłaszcza na konieczność ponownego „połączenia budynku z kontekstem”3, to Autor podejmuje rozważania na temat samego już warsztatu pracy architekta, a dokładniej – podstawowego narzędzia, jakim jest rysunek. Stawia tezy mówiące o tym, czym dzisiaj powinny być dla architekta tytułowe zagadnienia.
Źródło:
Builder; 2021, 25, 6; 76-78
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wskaźnikowa ocena wartości estetycznej krajobrazu miejskiego na przykładzie centrum Wieliczki
Indicative assessment of the aesthetic value of the urban landscape on the example of the Wieliczka Center
Autorzy:
Kowalczyk, Krzysztof A.
Powiązania:
https://bibliotekanauki.pl/articles/2109550.pdf
Data publikacji:
2021-11-23
Wydawca:
Uniwersytet Łódzki. Wydawnictwo Uniwersytetu Łódzkiego
Tematy:
estetyka krajobrazu
fizjonomia krajobrazu
wnętrze krajobrazowo-urbanistyczne
ocena wartości estetycznej krajobrazu
Wieliczka
landscape aesthetics
landscape physiognomy
landscape-urban enclosure
assessment of the aesthetic value of the landscape
Opis:
Oceny estetyczne krajobrazu są badaniami trudnymi, opartymi przeważnie na subiektywnych metodach i hybrydowych narzędziach badawczych. Potrzeba badań estetycznych krajobrazu wyrasta z dbałości i troski nie tylko o ład przestrzenny, ale także o jakość życia oraz środowiska zamieszkania, pracy i wypoczynku. Omawiany w artykule krajobraz rozpatrywany będzie w ujęciu estetycznym w kategoriach fizjonomicznych jako percypowany krajobraz wizualny. Pierwszym problem w ocenach estetycznych krajobrazu jest wybór właściwej jednostki przestrzennej mogącej oddać rzeczywiste cechy krajobrazu. W artykule postuluje się wykorzystanie jako podstawowych jednostek dla percepcji krajobrazu miejskiego wnętrz krajobrazowo-urbanistycznych wyznaczonych według kryteriów widokowego i urbanistycznego. W kolejnej części przeprowadzona zostanie dwuetapowa analiza wnętrz krajobrazowo-urbanistycznych pod względem wartości i atrakcyjności wizualnej. Pierwszym etapem jest identyfikacja i ocena miejskich krajobrazów estetycznych – temu służyć ma wskaźnikowa ocena wartości estetycznej krajobrazu miejskiego. Wśród zalecanych grup wskaźników znalazły się takie cechy krajobrazu jak: barwność i oświetlenie, czystość i porządek, dostępność wnętrza, funkcjonalność zasobów wnętrza, jakość i stan techniczny wnętrza, kompozycja i rozplanowanie, morfologia i budowa wnętrza, ozdobność i umeblowanie, proporcjonalność elementów wnętrza, przestrzenność (przestronność) wnętrza, reprezentatywność wnętrza, różnorodność zasobów wnętrza, tożsamość i symboliczność, widoczność oraz zwartość i spoistość ścian wnętrza. Drugim etapem jest wyszczególnienie negatywnych i pozytywnych wzorców krajobrazowo-estetycznych dla wypracowania wytycznych w celu ochrony lub poprawy krajobrazu o najwyższych i najniższych ocenach. W badaniach tych należy zastosować analizę widokowo-kompozycyjną (przy wykorzystaniu fotografii widoku lub panoramy) w oparciu o dostępne już metody i narzędzia badawcze pochodzące z literatury. Wynikiem badań jest opracowanie graficzne w postaci kartogramu pokazującego miejskie krajobrazy estetyczne oraz serii wytycznych odnośnie kształtowania i ochrony estetyki krajobrazu. Studium przypadku oparto na centrum miasta Wieliczki, gdyż posiada cechy typowe dla obszarów śródmiejskich miast małych i średnich w Polsce. W strukturze badanego centrum miasta w oparciu o kryteria widokowe i urbanistyczne wyznaczono 42 wnętrza krajobrazowo-urbanistyczne. W badaniach najwyższe oceny wartości estetycznej uzyskały wnętrza placowe, następnie parkowe, na końcu uliczne. Wśród wskaźników najlepiej ocenianych znalazły się te związane z „czystością i porządkiem”, „proporcjonalnością elementów wnętrza”, „przestrzennością wnętrza” i „dostępnością”, które bardzo często przypisywane są w badaniach geograficznych (i nie tylko) pojęciu „ładu przestrzennego”. Wnętrza z najwyższą oceną zlokalizowane są w centralnej i północnej części centrum Wieliczki obejmując swym zasięgiem historyczny zespół urbanistyczny i ciąg wnętrz wzdłuż ważniejszej arterii komunikacyjnej w mieście. Najniższą ocenę estetyczną uzyskały wnętrza zlokalizowane na obrzeżach centrum. Cechują się one dominacją funkcji komunikacyjnej (parkingi) z brakiem lub pociętą linią zabudowy o dość swobodnym rozplanowaniu. W artykule analizę kompozycyjno-widokową przeprowadzono dla jednego z wnętrz o najwyższej ocenie – plac Skulimowskiego. Wnętrze tego placu miejskiego tworzy wyjątkowo harmonijny krajobraz z nieprzekraczającym 1% widoku wnętrza udziałem obiektów dysharmonijnych. W badaniach uwydatniła się szczególna funkcja zieleni wysokiej jako formy wiążącej kompozycję wnętrz oraz budującej ściany i „plombującej” luki w spójności linii zabudowy. Metoda stanowi propozycję i głos w dyskusji na temat identyfikacji krajobrazów estetycznych w przestrzeni miejskiej wpisując się w kierunek krajobrazowy badań nad miastem w nurcie fizjonomiczno-estetycznym na gruncie geografii (szczególnie geografii społeczno-ekonomicznej i gospodarki przestrzennej).
Aesthetic landscape assessments are difficult studies, mostly based on subjective methods and hybrid research tools. The need for aesthetic landscape research derives from the care and concern not only for spatial order, but also for the quality of life and the of living, work and leisure environment. The landscape discussed in the article will be considered aesthetically in physiognomic terms as an perceived visual landscape. The first problem in the aesthetic assessments of landscape is the choice of the appropriate spatial unit that can reflect the real features of that landscape. It is postulated to use of landscape and urban enclosures designated according to the viewing and urban planning criteria as the basic units for the perception of the urban landscape. In the next part there will be a two-stage analysis of landscape and urban enclosures in terms of value and visual attractiveness. The fist stage is the identification and assessment of urban aesthetic landscapes – this indicator is used to assess the value of aesthetic urban landscape. The recommended groups of indicators include such landscape features as: colour and lighting, cleanliness and order, accessibility, functionality of enclosures  resources, quality and technical condition, composition and arrangement, enclosures morphology and construction, decorativeness and urban furniture, proportionality of enclosures elements, spatiality (spaciousness), representativeness of the enclosures, diversity of enclosures resources, identity and symbolism, visibility as well as the compactness and coherence of enclosures walls. The second step is to specify the positive and negative landscape and aesthetic patterns in order to develop guidelines for the protection or improvement of the landscape with the highest and lowest values. In these studies, a view-composition analysis should be used based on the research methods and tools already available from the literature. The result of the research is a graphic design in the form of a choropleth map showing urban aesthetic landscapes and a series of guidelines for shaping and protecting the aesthetics of the landscape. The case study was based on the center of the town of Wieliczka, as it has the features typical of inner-city areas of small and medium-sized town in Poland. In the structure of the examined town center, 42 landscape and urban enclosures were determined based on the viewing and urban planning criteria. Among the best rated indicators there are those related to cleanliness and order, proportionality of enclosures elements, spatiality and accessibility, which are very often ascribed in geographical research (and not only) to the concept of spatial order. The enclosures with the highest rating are located in the central and northern part of the center of Wieliczka, covering the historic urban complex and a sequence of enclosures along the most important communication artery in the town. The lowest aesthetic rating was given to the enclosures located on the outskirts of the center. They are characterized by the dominance of the communication function (parking lots) with no or a cut line of buildings with a fairly free arrangement. In the article, the composition and viewing analysis was carried out for one of the highest-rated enclosure – Skulimowski Square. This enclosure creates an exceptionally harmonious landscape with a share of disharmonious objects not exceeding 1% of the enclosure view. The research emphasized the special function of tall greenery as a form binding the enclosure composition and building walls and “sealing” gaps in the coherence of the building line. The method is a proposal and a voice in the discussion on the identification of aesthetic landscapes in urban space, fitting into research on the landscape of the city in the physiognomic and aesthetic trend in geography (especially socio-economic geography and spatial management).
Źródło:
Space – Society – Economy; 2021, 32; 7-37
1733-3180
2451-3547
Pojawia się w:
Space – Society – Economy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A brief history of Pachoras from the 5th to the 7th centuries
Autorzy:
Godlewski, Włodzimierz
Powiązania:
https://bibliotekanauki.pl/articles/1634058.pdf
Data publikacji:
2020-12-19
Wydawca:
Uniwersytet Warszawski. Wydawnictwa Uniwersytetu Warszawskiego
Tematy:
Makuria
Nobadia
Pachoras
destruction of the Enclosure
Opis:
The development of Pachoras, an important town in mid-5th century AD Nobadia, was broken violently by a flood at the beginning of the second half of the 6th century. The settlement and enclosure were devastated and abandoned until the close of the 6th century when the Cathedral of Aetios was built on a 5-m-high dune, engulfing the interior of the enclosure.
Źródło:
Polish Archaeology in the Mediterranean; 2020, 29(2); 695-713
1234-5415
Pojawia się w:
Polish Archaeology in the Mediterranean
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analogy between thermal and mass diffusion effects of a free convective flow in rectangular enclosure
Autorzy:
Ambethkar, Vusala
Powiązania:
https://bibliotekanauki.pl/articles/1839737.pdf
Data publikacji:
2020
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
free convective flow
thermal diffusion effects
mass diffusion effects
rectangular enclosure
average Nusselt number
average Sherwood number
empirical correlations
swobodny przepływ konwekcyjny
efekty dyfuzji termicznej
efekty dyfuzji masowej
korelacje empiryczne
średnia liczba Sherwooda
średnia liczba Nusselta
Opis:
In this investigation, the analogy between thermal and mass diffusive effects of a free convective flow in a rectangular enclosure is emphasized. The upwind finite volume method is used to discretize the governing equations of the continuity, momentum, energy and mass transfer. The novelty in this exploration is to appropriately modify the well-known Semi-Implicit Method for Pressure-Linked Equations (SIMPLE) algorithm so that it suits to the present problem and thereby, the new flow variables such as the temperature and the concentration are computed. An empirical correlation for the average Sherwood number (Sh) that does not exist in literature is suggested in this work. The average Sherwood numbers for distinct fluids (gases and liquids) are calculated, and mass diffusion effects within the horizontal rectangle are analyzed. The average Nusselt numbers (Nu) are calculated for distinct fluids such as liquids (Pr ≫1), liquid metals (Pr≪1) and gases (Pr < 1) for different Rayleigh numbers in the range of 3x105 ≤ RaL ≤ 7x10 9 from relevant empirical correlations existing in the literature. Accordingly, the thermal diffusion effects within the horizontal rectangle are analyzed.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2020, 19, 4; 5-20
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analogy between thermal and mass diffusion effects of a free convective flow in rectangular enclosure
Autorzy:
Ambethkar, Vusala
Powiązania:
https://bibliotekanauki.pl/articles/1839750.pdf
Data publikacji:
2020
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
free convective flow
thermal diffusion effects
mass diffusion effects
rectangular enclosure
average Nusselt number
average Sherwood number
empirical correlations
swobodny przepływ konwekcyjny
efekty dyfuzji termicznej
efekty dyfuzji masowej
korelacje empiryczne
średnia liczba Sherwooda
średnia liczba Nusselta
Opis:
In this investigation, the analogy between thermal and mass diffusive effects of a free convective flow in a rectangular enclosure is emphasized. The upwind finite volume method is used to discretize the governing equations of the continuity, momentum, energy and mass transfer. The novelty in this exploration is to appropriately modify the well-known Semi-Implicit Method for Pressure-Linked Equations (SIMPLE) algorithm so that it suits to the present problem and thereby, the new flow variables such as the temperature and the concentration are computed. An empirical correlation for the average Sherwood number (Sh) that does not exist in literature is suggested in this work. The average Sherwood numbers for distinct fluids (gases and liquids) are calculated, and mass diffusion effects within the horizontal rectangle are analyzed. The average Nusselt numbers (Nu) are calculated for distinct fluids such as liquids (Pr ≫1), liquid metals (Pr≪1) and gases (Pr < 1) for different Rayleigh numbers in the range of 3x105 ≤ RaL ≤ 7x10 9 from relevant empirical correlations existing in the literature. Accordingly, the thermal diffusion effects within the horizontal rectangle are analyzed.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2020, 19, 4; 5-20
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of noise transmission of a machine tool enclosure
Autorzy:
Bleicher, Friedrich
Reichl, Christoph
Linhardt, Felix
Wimberger, Peter
Habersohn, Christoph
Krall, Stephan
Powiązania:
https://bibliotekanauki.pl/articles/99968.pdf
Data publikacji:
2019
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
sound pressure level
machine enclosure
noise transmission
acoustic grid
Opis:
Machine tools are highly integrated mechatronic systems consisting of dedicated mechanic design and integrated electrical equipment – in particular drive systems and the CNC-control – to realize the complex relative motion of tool towards work piece. Beside the process related capabilities, like static and dynamic stiffness as well as accuracy behavior and deviation resistance against thermal influence, safety aspects are of major interest. The machine tool enclosure must fulfill multiple requirements like retention capabilities against the moving parts of broken tools, lose work pieces or clamping components. In regular use, the noise emission have to be inhibited at the greatest possible extent by the machine tool enclosure. Nevertheless, the loading door and the moving parts of the workspace envelope are interfaces where noise transmission is harder to be avoided and therefore local noise emissions increase. The aim of the objective investigation is to analyse the noise emission of machine tools to determine the local noise transmission of a machine tool enclosure by using arrays of microphones. By the use of this measuring method, outer surfaces at the front, the side and on the top of the enclosure have been scanned. The local transient acoustic pressures have been recorded using a standard noise source placed on the machine table. In addition, an exemplary manufacturing process has been performed to analyse the frequency dependent location resolved sound emissions.
Źródło:
Journal of Machine Engineering; 2019, 19, 3; 5-16
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Gumelnița culture settlements in the Prut-Dniester Rivers area, in light of old and new research from Taraclia I (Republic of Moldova)
Autorzy:
Mistreanu, Eugeniu
Przybyła, Marcin M.
Powiązania:
https://bibliotekanauki.pl/articles/958150.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Rzeszowski. Instytut Archeologii Uniwersytetu Rzeszowskiego. Muzeum Okręgowe w Rzeszowie
Tematy:
Eneolithic
Gumelniţa-Kodjadermen-Karanovo VI cultural complex
Gumelniţa culture
enclosure
fortified
settlement
Opis:
The discovery of the first Gumelniţa Culture settlements in the region between the Prut and the Dniester Rivers dates back to the 1960s and 1970s. Currently, thirty three settlements of this culture are known in the territory of Ukraine and Moldova. One of them, representing the Stoicani-Aldeni of Gumelniţa Culture variant, is located in Taraclia (Taraclia district, Republicof Moldova). It has been excavated since 1979. In the spring of 2018, magnetic research was carried out on the site. They revealed the presence of a fortification system surrounding an area of approximately 1.7 hectares. It consisted of two parallel ditches forming a quadrangular arrangement. Similar fortifications have been discovered on sites belonging to the Gumelniţa-Kodjadermen-Karanovo VI cultural complex, located in the South-Eastern European region.
Źródło:
Analecta Archaeologica Ressoviensia; 2019, 14; 17-39
2084-4409
Pojawia się w:
Analecta Archaeologica Ressoviensia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zasadnicze zmiany w kanonicznym życiu kontemplacyjnym mniszek według konstytucji apostolskiej Vultum Dei quaerere i instrukcji Cor orans
Autorzy:
Szewczul, Bożena
Powiązania:
https://bibliotekanauki.pl/articles/1372330.pdf
Data publikacji:
2019-03-09
Wydawca:
Uniwersytet Kardynała Stefana Wyszyńskiego w Warszawie
Tematy:
mniszka
kanoniczne życie kontemplacyjne
autonomia
klauzura
federacje
formacja zakonna
nuns
canonical contemplative life
autonomy
enclosure
federation of monasteries
formation
Opis:
Apostolic constitution of Pope Francis regarding women’s contemplative life Vultum Dei quaerere published on 29.06.2016, and executory instruction Cor orans published on 1.04.2018 by Congregation for Institutes of Consecrated Life and Societies of Apostolic Life implements series of changes for life of nuns of enclosure. It was necessary, because previous apostolic constitution Sponsa Christi regarding life of nuns, prepared by Pope Pius XII was published 66 zears ago on 21.1.1915. Long time period separating both constitutions causes, among other things, that changes implemented by new documents are far-reaching, and cause partial derogation of four canons Canon Law Codex of 1983 still in force, and complete abrogation of some previous, no-code judical norms regarding nuns. Newness (Novum) of the published documents, in the first place, is that all nun’s cloisters have an obligation of membership of the respective federation; description of the required conditions necessary for the cloister to receive real, and judiciary autonomy, and reasons of its loss; changes in institution of enclosure, and exlaustration of the nuns, as well as extention of initial nun’s formation, and implementation of additional, obligatory stages in it, that is aspirant’s, and postulate’s period. All above mentioned changes have been discussed in the article. Changes are proceded by recalling the definition of the canonical contemplation life, formulated bz Pope Pius XI in reminded above constitution Sponsa Christi, and mentioned by Pope Francis again in constitution Vultum Dei quaerere. This type of the article structure seemed to be necessary, in order to allow reader to make an evaluation of the changes in a life of nuns, and first of all to get an answer to a question: if the changes will more successfuly lead the nuns to interior contemplation? General historical, and statistical facts regarding the life of nuns were also included in the article.
Źródło:
Prawo Kanoniczne; 2019, 62, 1; 53-82
2353-8104
Pojawia się w:
Prawo Kanoniczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A New Concept of Electrical-Equipment Explosion Protection Utilising Pressurised Enclosures and Stationary Nitrogen Installations
Nowa koncepcja ochrony przeciwwybuchowej urządzenia wykorzystująca osłonę nadciśnieniową oraz stacjonarną instalację azotu
Autorzy:
Ptak, S.
Powiązania:
https://bibliotekanauki.pl/articles/373654.pdf
Data publikacji:
2018
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
ex equipment
electrical devices
explosion protection
pressurised enclosure
urządzenia elektryczne
odciążanie wybuchu
ochrona przeciwpożarowa
Opis:
Aim: In the engineering practice, explosion protection is provided through the following steps: the elimination of the flammable material, the explosive atmosphere and the source of ignition. Another step is to limit the impact of the potential explosion. Electrical equipment might constitute the source of ignition for mixtures of flammable substances with air. The aim of the article is to present a new type of electrical equipment protection. According to the current technical standards, Ex p equipment is defined either as an enclosure with a constant static overpressure inside or purged enclosures with the use of clean air not containing flammable substances that could generate a hazardous atmosphere. This type of protection usually requires regular maintenance, complicated venting and/or frequent control of correct operation. Project and methods: Electrical equipment designed to work in hazardous areas is designed with various types of protection ensuring safety in the case of a hazardous atmosphere created near the device. In order to present the concept of the new protection type, current technical standards were analysed to gather technical prerequisites. The Solid Edge environment was used to create 3D models of control and indicating equipment (CIE). The diagram presenting the concept of the whole device was also created. The aim of the project was to present the concept of the new mixed-type pressurised equipment. Results: The design of the device proves that it is possible to create a new type of explosion protection of electrical equipment which has not been described in current technical standards. The concept assumes the use of stationary compressed nitrogen installations present in many factories. The installation will maintain a constant positive pressure inside the enclosure. It is also feasible to use portable inert gas tanks, which will require additional means of protection. The proposed design was checked against the set requirements. For the designed equipment, ready formulae were used to determine screw tightening torques in order to activate the device after exceeding specific parameters, such as the gas flow rate. Conclusions: The current technical standards give space for designing a new type of electrical equipment protection. The article describes the outcomes of the research and project work conducted to visualise the concept. These types of equipment protection can be certified for all working conditions, which increases their applicability potential.
Cel: W praktyce inżynierskiej ochrona przed wybuchem polega na eliminacji materiału palnego, atmosfery wybuchowej oraz źródła zapłonu. Kolejnym krokiem jest ograniczenie możliwych skutków wybuchu. Potencjalnym źródłem zapłonu mieszaniny powietrza z materiałem palnym są urządzenia elektryczne. Celem artykułu jest zaprezentowanie nowej koncepcji budowy przeciwwybuchowej tego typu urządzeń. Obowiązujące normy opisują urządzenia Ex p jako utrzymujące stałe nadciśnienie wewnątrz obudowy lub jako wentylowane powietrzem niezanieczyszczonym gazami palnymi. Zapewnienie ochrony przeciwwybiuchowej urządzeń tego typu jest jednak problematyczne, ponieważ wymaga skomplikowanego układu instalacji wentylacyjnej, a także częstej kontroli pracy. Projekt i metody: Urządzenia elektryczne przeznaczone do użytkowania w przestrzeniach zagrożonych wybuchem konstruowane są z wykorzystaniem różnego rodzaju założeń bezpieczeństwa na wypadek wystąpienia atmosfery wybuchowej. W celu przedstawienia nowej koncepcji ochrony przeciwwybuchowej dokonano analizy obowiązujących norm oraz określono zbiór założeń projektowych. Wykorzystano środowisko Solid Edge do stworzenia modeli 3D urządzeń kontrolnych i sterujących. Następnie opisano schemat blokowy najistotniejszych części urządzenia. Celem prac projektowych było zaprezentowanie nowej mieszanej koncepcji budowy przeciwwybuchowej urządzeń elektrycznych, którą nazwano roboczo Ex pN. Wyniki: Zaprojektowane rozwiązanie dowodzi, że możliwe jest stworzenie nowej budowy przeciwwybuchowej urządzeń, nieopisanej w normach. Wykorzystuje ona stacjonarne instalacje ze sprężonym azotem obecne w wielu zakładach produkcyjnych. Utrzymują one stałe nadciśnienie gazu inertnego wewnątrz obudowy urządzenia. Możliwe jest także wykorzystanie przenośnych zbiorników z gazem obojętnym, które wymaga jednak zastosowania dodatkowych środków bezpieczeństwa. Proponowane rozwiązania sprawdzono pod względem postawionych założeń projektowych. Dla zaprojektowanych urządzeń podano gotowe wzory do wyznaczenia momentów siły, jaką należy przyłożyć do śrub regulacyjnych, aby uruchomienie nastąpiło po przekroczeniu określonego parametru pracy urządzenia, np. prędkości przepływu gazu.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2018, 49, 1; 94-100
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies