Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "e. coli" wg kryterium: Temat


Tytuł:
Water quality and microbial contamination status of groundwater in Jaffna Peninsula, Sri Lanka
Jakość wody i mikrobiologiczne zanieczyszczenie wód gruntowych na półwyspie Jaffna na Sri Lance
Autorzy:
Mahagamage, M. G. Y. L.
Manage, Pavithrani S.
Manage, Pathmalal M.
Powiązania:
https://bibliotekanauki.pl/articles/292453.pdf
Data publikacji:
2019
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
coliform
E.coli
groundwater
Jaffna Peninsula
Salmonella spp.
Shigella spp
water quality
bakterie z grupy coli
Escherichia coli
jakość wody
półwysep Jaffna
Shigella spp.
wody gruntowe
Opis:
In Sri Lanka, among 2588 Salmonella positive cases, the highest incidences were recorded from Jaffna peninsula during 2005 to 2013. Therefore, the present study aimed to identify the microbiological and chemical contamination status of groundwater (40 well water) sources in Jaffna during November 2016. The total coliform, E. coli, Salmonella spp. and Shigella spp. along with some physico-chemical parameters of groundwater were studied. The results revealed that entire peninsula was contaminated with total coliform and E. coli bacteria and the parameters recorded were not within the WHO and SLS (Sri Lanka Standards) drinking water quality standards. 38% of sampling locations were positive for Salmonella spp. and among them six sampling locations were being used for drinking purposes. The results of the study correlates with the statistics of typhoid cases recorded in Jaffna. Results of the study also revealed that around 80% of wells were not within the values specified in guidelines of the SLS for drinking water quality on electrical conductivity. Further, 15% of wells recorded greater than 10 mg∙dm–3 nitrate, which is still below the SLS drinking water standards (45 mg∙dm–3). According to the water quality data, PCA analysis showed that Jaffna town, Nallur, Tellippalai and Kopay DS divisions has similar characteristics for water quality.
Spośród 2588 przypadków zatrucia salmonellą zanotowanych na Sri Lance największą liczbę zachorowań stwierdzono na półwyspie Jaffna w latach 2005–2013. Dlatego prezentowane badania miały na celu identyfikację chemicznego i mikrobiologicznego zanieczyszczenia wód gruntowych z 40 studni w listopadzie 2016 r. Analizowano całkowitą liczbę bakterii z grupy coli, Escherichia coli, Salmonella spp., Shigella spp. oraz wybrane parametry fizyczne i chemiczne wód gruntowych. Wyniki ujawniły, że cały półwysep jest skażony bakteriami z grupy coli i bakterią Escherichia coli, a analizowane parametry nie spełniają standardów WHO i standardów Sri Lanki co do jakości wody. W 38% badanych stanowisk stwierdzono obecność Salmonella spp., przy czym sześć z nich wykorzystywano jako źródła wody pitnej. Wyniki badań korelowały z rejestrowanymi przypadkami duru brzusznego na półwyspie. Stwierdzono także, że 80% studni nie spełniało wymogów stawianych wodzie pitnej przez normy Sri Lanki w odniesieniu do przewodnictwa elektrolitycznego. Ponadto stężenie azotanów w 15% studni było większe niż 10 mg∙dm–3, ale nie przekraczało granicznej wartości 45 mg∙dm–3 wyznaczonej przez normy dla wody pitnej. Analiza PCA wykazała, że miasto Jaffna oraz gminy Nallur, Tellippalai i Kopay mają wody o podobnych właściwościach.
Źródło:
Journal of Water and Land Development; 2019, 40; 3-12
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using multitype branching models to analyze bacterial pathogenicity
Autorzy:
Tahir, Daniah
Kaj, Ingemar
Bartoszek, Krzysztof
Majchrzak, Marta
Parniewski, Pawel
Sakowski, Sebastian
Powiązania:
https://bibliotekanauki.pl/articles/747904.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Matematyczne
Tematy:
Markov models
branching processes
limit theorems
virulence factors
E. coli strains
Opis:
We apply multitype, continuous time, Markov branching models to study pathogenicity in E. coli, a bacterium belonging to the genus Escherichia. First, we examine briefly, the properties of multitype branching processes and we also survey some fundamental limit theorems regarding the behavior of such models under various conditions. These theorems are then applied to discrete, state dependent models, in order to analyze pathogenicity in a published clinical data set consisting of 251 strains of E. coli. We use well established methods, incorporating maximum likelihood techniques, to estimate speciation rates as well as the rates of transition between different states of the models. From the analysis, we not only derive new results, but we also verify some preexisting notions about virulent behavior in bacterial strains.
Źródło:
Mathematica Applicanda; 2020, 48
1730-2668
2299-4009
Pojawia się w:
Mathematica Applicanda
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Type 1 fimbriae in commensal Escherichia coli derived from healthy humans
Autorzy:
Pusz, Paweł
Bok, Ewa
Mazurek, Justyna
Stosik, Michał
Baldy-Chudzik, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/1039310.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
commensal E. coli
type 1 fimbriae
gene expression
Opis:
Type 1 fimbriae are one of the most important factors of Escherichia coli adaptation to different niches in the host. Our study indicated that the genetic marker - fimH gene occurred commonly in commensal E. coli derived from healthy humans but expression of the type 1 fimbriae was not observed. Identification of fim structural subunit genes (fimA-fimH) and recombinase fimE and fimB genes showed that many of the strains were carrying an incomplete set of genes and the genes expression study revealed that in strains with complete set of fim genes, the fimC gene, encoding the chaperone protein, was not expressed.
Źródło:
Acta Biochimica Polonica; 2014, 61, 2; 389-392
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The number of E. coli and C. perfringens bacteria in poultry waste and subsequent phases of composting
Liczebność bakterii E. coli i C. perfringens w odpadach drobiarskich oraz kolejnych fazach ich kompostowania
Autorzy:
Cybulska, K.
Suchecka, N.
Wrońska, I.
Mahdi-Oraibi, S.
Powiązania:
https://bibliotekanauki.pl/articles/125776.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
E.coli
C. perfringens
poultry waste
composting
E. coli
odpady drobiarskie
kompostowanie
Opis:
Rapidly growing commercial poultry production generates large amounts of waste. Waste that accumulates during the poultry slaughter process often remains unprocessed, becoming a serious threat to people’s health and the natural environment. Poultry production waste constitutes problems odour threat and dangerous sanitary threat. The aim of this study was to determine the population size of Escherichia coli and Clostridium perfringens in poultry waste and in successive stages of waste composting. Research material consisted of raw feathers collected immediately after the slaughter, samples of biological sludge from the centrifuge, mixture of straw, feathers and lime and processed compost. Microbiological analyses were conducted with the use of spread plate count method and the substrate was used in accordance with research standards. The size of population of microorganisms in the samples analyzed corresponded to the waste processing stage and group of microbes. The presence of C. perfringens strains was ascertained in all samples, whereas E. coli strains were identified only in raw feathers and centrifuge sludge, being most numerous in unprocessed material. A reverse trend was observed in case of C. perfringens with the highest population density in centrifuge sludge and least density in raw feathers.
Intensywnie rozwijająca się produkcja drobiarska wiąże się z generowaniem dużej ilości odpadów. Powstające produkty uboczne podczas uboju pozostawione w stanie surowym stają się poważnym zagrożeniem dla środowiska naturalnego i zdrowia ludzi. Mogą stwarzać problemy odorotwórcze oraz istotnie groźne zanieczyszczenie sanitarne. Celem przeprowadzonych badań było określenie liczebności E. coli i C. perfringens w odpadach drobiarskich oraz kolejnych etapach ich kompostowania. Materiał badawczy stanowiły świeże pióra bezpośrednio po uboju, osad biologiczny z wirówki, mieszanina słomy, pierza i wapna oraz kompost przerobiony. Analizy mikrobiologiczne wykonano metodą płytkową, wykorzystując wybiórcze podłoża zgodne z normami. Liczebność mikroorganizmów w badanych próbach zależała od fazy przerobu odpadu i analizowanej grupy drobnoustrojów. Obecność bakterii C. perfringens stwierdzono we wszystkich próbach, natomiast bakterie E. coli tylko w piórach surowych i osadzie z wirówki, przy czym najliczniej występowały w materiale nieprzetworzonym. Odwrotną tendencję zaobserwowano w przypadku C. perfringens, które najliczniej zasiedlały osad z wirówki, natomiast ich mniejszą liczebność stwierdzono w piórach surowych.
Źródło:
Proceedings of ECOpole; 2015, 9, 1; 19-24
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of Garlic Extract Addition on Tilapia Skin Gelatin Based Edible Coating Towards Antimicrobial Properties and Fish Meatball’s Shelf Life
Autorzy:
Reynaldi, Ahmad
Rostini, Iis
Afrianto, Eddy
Rochima, Emma
Powiązania:
https://bibliotekanauki.pl/articles/1058047.pdf
Data publikacji:
2019
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
E. coli
Pseudomonas aeruginosa
Salmonella typhimurium
Staphyllococcus aureus
TPC
edible coating
extract
garlic
pH values
shelf life
tilapia gelatin
Opis:
The purpose of this research is to determine the best concentration and effect of garlic extract incorporated on tilapia skin gelatin-based edible coating to preserve and extend the shelf life of fish meatball at cold storage. This research was conducted from May 2018 until October 2018 on Fisheries Product Processing Laboratory of The Faculty of Fisheries and Marine Sciences, Universitas Padjadjaran. The garlic extract conducted with maceration method with ethanol 96% was performed at Organic Chemical Laboratory FMIPA Universitas Padjadjaran, and for TPC test, inhibition test of edible coating Tilapia’s fish-skin with garlic extract was conducted in Microbiology and Molecular Biotechnology Laboratory of Faculty of Fisheries and Marine Sciences Universitas Padjadjaran. The method used is experimental method with 5 treatments which is meatballs without edible coating. The addition of garlic extract was done with various concentration at 0%, 1%, 1.5%, 2%. The observations were Total Plate Count (TPC) test, inhibition zone test against Pseudomonas aeruginosa, and pH value. The results showed that the best treatment is 2% garlic extract with TPC value 1.1×105 cfu/g during 14 days of storage and concluded that it could extend the shelf life of meatball until 14 days, pH value was 7.03 and inhibition zone against P. aeruginosa was 7.01 mm. The addition of garlic extract on tilapia skin gelatin-based edible coating could extend the shelf life of fish meatballs until 14 days on cold storage.
Źródło:
World Scientific News; 2019, 134, 2; 74-85
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis of some Novel Halogenated Platinum (II) Complexes of Active Schiff’s Base Ligand Derived from 5-Bromo Isatin and Evaluation of their Antibacterial Activity
Autorzy:
Patange, Ashok N.
Yadav, Uttam M.
Desai, Pratik A.
Singare, Pravin U.
Powiązania:
https://bibliotekanauki.pl/articles/1194025.pdf
Data publikacji:
2015
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
5-bromo Isatin
Bacillus pumilus
E. Coli
Micrococcus Lutes
Salmonella abony
Schiff’s base
Semicarbazone
Thiosemicarbazone
Opis:
This paper presents the synthesis and antibacterial studies some novel halogenated Platinum (II) complexes of active Schiff’s base ligands of the type [Pt(L1H)2]Cl2, [Pt(L2H)2]Cl2 and[Pt(L)2] derived from 5-Bromo Isatin. Where L1H= hydrazinecarbothiamide of 5-bromoindolinedione and L2H = hydrazinecarboxamide of 5-bromoindolinedione. All complexes reported here had been characterised by 1H NMR and IR spectral studies. Molar conductance studies support the 1:2 natures of these complexes. Pt (II) complexes are diamagnetic in nature and showing square planner geometry. The IR spectral data reveals that both the Schiff’s bases (L1H and L2H) behave as bidentate ligands and are co-ordinated to Pt (II) metal through the sulfur and hydrogenic nitrogen atom.all the new synthesized compounds were screened for antibacterial activity against four of the test organisms like Bacillus pumilus, Micrococcus Lutes, E. coli and Salmonella abony
Źródło:
World Scientific News; 2015, 10; 32-43
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Struktury krzemionkowo-metaliczne – możliwości potencjalnych zastosowań
Autorzy:
Wenda, Magdalena
Zielecka, Maria
Jeziórska, Regina
Bujnowska, Elżbieta
Panasiuk, Marek
Cyruchin, Krystyna
Powiązania:
https://bibliotekanauki.pl/articles/460882.pdf
Data publikacji:
2015-03
Wydawca:
Mazowieckie Biuro Planowania Regionalnego w Warszawie
Tematy:
Escherichia coli
Staphylococcus aureus
Salmonella typhimurium
nanonapełniacze o właściwościach bakteriostatycznych
Nanomaterials, especially with antimicrobial properties (e.g. coatings and nanocomposites)
Opis:
Spośród licznej grupy nanomateriałów szczególną uwagę zwracają nanonapełniacze o właściwościach bakteriostatycznych oraz biobójczych, które stosowane są w tworzywach polimerowych, powłokach, farbach, materiałach medycznych czy tkaninach powlekanych. Krzemionkę o budowie sferycznej, zawierającej różne ilości immobilizowanego nanosrebra, otrzymywano metodą zol – żel w połączeniu z dwustopniową modyfikacją SiO2. Głównymi czynnikami decydującymi o zamierzonym efekcie syntezy jest pH mieszaniny reakcyjnej, szybkość mieszania oraz temperatura. Proponowany sposób otrzymywania krzemionki modyfikowanej nanosrebrem (SiO2-Ag) jest konkurencyjny w stosunku do konwencjonalnych ze względu na unikatowe właściwości tych materiałów. Wbudowanie nanosrebra w strukturę nanokrzemionki zapewnia uzyskanie jej trwałej nanostruktury, co w konsekwencji umożliwia doskonałe zdyspergowanie nanocząstek w osnowie polimerowej. Powtarzalne właściwości nanokrzemionki są zgodne z oczekiwaniami i gwarantują przy tym wysoką jakość otrzymywanych produktów. Aktywność antymikrobową otrzymanych materiałów oceniano wobec bakterii Escherichia coli, Staphylococcus aureus oraz Salmonella typhimurium. Nanometryczny rozmiar cząstek wpływa na zwiększenie ich aktywności biologicznej i chemicznej. Wskazuje to na wzmożoną skuteczność nanocząstek wobec mikroorganizmów.
Nanomaterials, especially with antimicrobial properties (e.g. coatings and nanocomposites) are presently in great demand with increasing interest for application due to their diversity, unique properties, and seemingly limitless uses. They are currently in commercial use and new ones keep coming on the market. Our study is related to a new group of nanomaterials, namely silica nanospheres containing immobilized silver NPs (Ag-SiO2), which can be successfully used as a fascinating nanofillers in preparation new class of nanocomposites, additives for architectural paints and impregnates. The original synthesis method of spherical silica nanoparticles (NPs) with immobilized silver NPs allows preparation of uniform and size controllable nanoparticles with improved microbiological activity of the Ag-SiO2 containing composite powders. Due to extensive works that are being conducted in our laboratories, mainly based on optimization and modification of silica matrices we achived of a potential novel class of materials with unique antimicrobial properties. Simple and reliable manufacturing technology (sol-gel) for the production of silica containing immobilized nanosilver offers a possibility to control size and uniformity of nanospheres. The properties of obtained by this method silica nanopowders containing immobilized nanometric silver particles are important in the use of such powders as components of polymer nano and micro composites used in conditions favoring growth of bacteria and fungi. They prevent the growth of bacteria in moistened compartments on polymers nanocomposites. Microbilogical examination were performed for Escherichia coli, Staphylococcus aureus and Salmonella typhimurium. The antimicrobial efficiency of these materials increase with decreasing their particle size due to their larger specific area.
Źródło:
MAZOWSZE Studia Regionalne; 2015, 16; 141-148
1689-4774
Pojawia się w:
MAZOWSZE Studia Regionalne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spontaneous mutagenesis in exponentially growing and stationary-phase, umuDC-proficient and -deficient, Escherichia coli dnaQ49.
Autorzy:
Nowosielska, Anetta
Nieminuszczy, Jadwiga
Grzesiuk, Elżbieta
Powiązania:
https://bibliotekanauki.pl/articles/1041546.pdf
Data publikacji:
2004
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
dnaQ49
argE3→Arg+ revertants
E. coli
Pol V
spontaneous mutagenesis
stationary-phase mutations
Opis:
Spontaneous mutations arise not only in exponentially growing bacteria but also in non-dividing or slowly dividing stationary-phase cells. In the latter case mutations are called adaptive or stationary-phase mutations. High spontaneous mutability has been observed in temperature sensitive Escherichia coli dnaQ49 strain deficient in 3'→5' proofreading activity assured by the ε subunit of the main replicative polymerase, Pol III. The aim of this study was to evaluate the effects of the dnaQ49 mutation and deletion of the umuDC operon encoding polymerase V (Pol V) on spontaneous mutagenesis in growing and stationary-phase E. coli cells. Using the argE3OC →Arg+ reversion system in the AB1157 strain, we found that the level of growth-dependent and stationary-phase Arg+ revertants was significantly increased in the dnaQ49 mutant at the non-permissive temperature of 37°C. At this temperature, in contrast to cultures grown at 28°C, SOS functions were dramatically increased. Deletion of the umuDC operon in the dnaQ49 strain led to a 10-fold decrease in the level of Arg+ revertants in cultures grown at 37°C and only to a 2-fold decrease in cultures grown at 28°C. Furthermore, in stationary-phase cultures Pol V influenced spontaneous mutagenesis to a much lesser extent than in growing cultures. Our results indicate that the level of Pol III desintegration, dependent on the temperature of incubation, is more critical for spontaneous mutagenesis in stationary-phase dnaQ49 cells than the presence or absence of Pol V.
Źródło:
Acta Biochimica Polonica; 2004, 51, 3; 683-692
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Screening for ESβL producing E. coli isolated from clinical urine samples collected from different places of Kalaburagi city
Autorzy:
Ramachar, Raghavendra
Gaddad, Subhashchandra M.
Shivannavar, Channappa T.
Powiązania:
https://bibliotekanauki.pl/articles/1177430.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Antibiogram
Double-disc diffusion test
ESβL
Green Metallic Sheen
Phenotypic detection
Uropathogenic E. coli
Opis:
Bacteria are capable of invading and infecting humans, leading to disease and sometimes death. Different body tissues, organs and systems are vulnerable to different organisms. This study was aimed to isolate and identify the bacteria causing Urinary Tract Infection (UTI) in different age groups and also screened for ESβL production. The mid-stream urine samples showing symptoms of urinary tract infections were collected in a wide container from different hospitals and diagnostic centres of Kalaburagi city. The isolation of uropathogen was done by semi-quantitative method of inoculating the samples on the selective and differential media such as Eosin Methylene Blue (EMB) and MacConkey (MAC) agar media respectively. The isolated pathogen was identified by conventional methods like cultural, morphological and biochemical tests. The antibiotic susceptibility test was carried out by Kirby-Bauer disc diffusion technique and ESβL production by double disk-diffusion test (DDDT) as per CLSI guidelines (2013). Out of 550 samples screened, a total of 288 bacteria were isolated of those half of them (146) were E. coli isolates and all were found to be multidrug resistant and half of them (50%) were of ESβL producers. All ESβL producing E. coli isolates were resistant to ceftazidime and exhibited higher level of resistance to Cephalothin, Erythromycin, Cotrimoxazole and Aztreonam. As ESβL producing organisms limits the available treatment options, so, the timely administration of sensitive antibiotic and avoiding antibiotic abuse will help in curing the disease without going for the costly drugs such as Carbapenems. Our study revealed that nitrofurantoin, ofloxacin and cefoxitin may be considered as drug of choice for the treatment of UTI patients. The ESβL production in uropathogens should be continuously monitored in the clinics and hospitals as to avoid the emergence of more multi drug resistance strains.
Źródło:
World Scientific News; 2018, 103; 107-118
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sanitary evaluation of the water from water intake points situated in Gorzow Wielkopolski and neighbouring localities
Ocena sanitarna wody pochodzącej z ujść wodnych na terenie Gorzowa Wielkopolskiego oraz okolic
Autorzy:
Wrońska, I.
Cybulska, K.
Powiązania:
https://bibliotekanauki.pl/articles/388391.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
drinking water
bacteria
E.coli
E. faecalis
water contamination
woda pitna
bakteria
E. coli
zanieczyszczenie wody
Opis:
Water is an essential component necessary for sustaining life. Nevertheless, it may pose a serious threat to human life resulting from possible occurrence of pathogenic and potentially pathogenic microorganisms. Therefore, monitoring and continuous microbial surveillance of the water intended for consumption is extremely important. The requirements referring to qualitative parameters which should be met by water are set out in the Regulation of the Minister of Health of 29 March 2007, as amended on 20 April 2010, and the EU directives. The quality of water being supplied to consumers depends on many factors, among other on the type of water intake (surface water or groundwater), efficiency of water treatment and disinfection, and technical condition of the water supply network. The analysis of the sanitary condition of drinking water has been conducted form water intakes in the city of Gorzow Wielkopolski, ie Centralny Kosynierow Gdynskich intake, Klodawa intake and Siedlice intake, and in neighbouring localities, ie. Maszewo and Marwice. The research material was raw and treated water samples. The population size of Faecal streptococci, coliform bacteria, including E. coli, and total mesophilic and psychrophilic bacteria counts was determined. The analysis of the sanitary condition of drinking water has been conducted. The number of coliform bacteria, including E. coli, and streptococci was determined by the method of membrane filters, whereas total mesophilic and psychrophilic bacteria counts using the plate method under incubation conditions conforming to the standards. The presence of mesophilic and psychrophilic bacteria was observed in all examined water intake points. Differences in their counts over the whole year being significant. In three research points, ie Centralny Kosynierow Gdynskich intake, Maszewo intake and Marwice intake, psychrophilic bacteria count was exceeded (100 CFU ۰ cm–3). In the case of pathogenic bacteria, their occurrence was occasionally observed in the drinking water intake points. The water treatment processes applied and, as the final result, water sanitary assessment according to the existing standards and the provision stipulated allow it to be collected for consumption purposes and do not pose the threat to human health and life.
Woda jest podstawowym składnikiem niezbędnym do utrzymania życia. Jednakże, może ona stworzyć poważne zagrożenie dla zdrowia człowieka wynikające z możliwości wystąpienia mikroorganizmów chorobotwórczych i potencjalnie chorobotwórczych. W związku z tym, niezwykle istotna jest kontrola oraz stały nadzór mikrobiologiczny nad wodą przeznaczoną do spożycia. Wytyczne co do parametrów jakościowych, jakim powinna odpowiadać, zawarte są w Rozporządzeniu Ministra Zdrowia z dnia 29 marca 2007 r. wraz ze zmianą z dnia 20 kwietnia 2010 r. oraz Dyrektywach Unii Europejskiej. Jakość wody dostarczanej konsumentom zależy od wielu czynników m.in.: rodzaju ujęcia (woda powierzchniowa lub podziemna), skuteczności procesów uzdatniania i dezynfekcji oraz stanu technicznego sieci wodociągowej. Przeprowadzono analizę stanu sanitarnego wody pitnej pochodzącej z ujęć wodnych zaopatrujących miasto Gorzów Wielkopolski, tj. ujęcie Centralne Kosynierów Gdyńskich, Kłodawa, Siedlice oraz sąsiadujące miejscowości, tj. Maszewo i Marwice. Materiałem badawczym były próbki wody surowej i uzdatnionej. Określono liczebność paciorkowców kałowych, bakterii z grupy coli, w tym E. coli oraz ogólnej liczebności bakterii mezofilnych i psychrofilnych. Liczebność bakterii z grupy coli, w tym E. coli oraz paciorkowców kałowych oznaczono metodą filtrów membranowych, zaś ogólną liczebność bakterii mezofilnych i psychrofilnych metodą płytkową w warunkach inkubacji zgodnych z normami. We wszystkich badanych punktach stwierdzono obecność bakterii mezofilnych i psychrofilnych. Różnice w ich liczebności na przestrzeni całego roku były istotne. W punktach badawczych, tj. Centralne Kosynierów Gdyńskich, Maszewo oraz Marwice odnotowano przekroczenie norm ilości psychrofilii 100 j.t.k. ۰ cm–3. Obecność bakterii chorobotwórczych w badanych próbkach wody pitnej wykryto sporadycznie. Zastosowane procesy uzdatniania i w efekcie końcowym ocena sanitarna wody według obowiązujących norm i zawartej klauzuli pozwalają na jej pobór do spożycia i nie stanowią zagrożenia dla zdrowia i życia ludzi.
Źródło:
Ecological Chemistry and Engineering. A; 2015, 22, 1; 17-26
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reverse osmosis as one-step wastewater treatment: a case study on groundwater pollution
Autorzy:
Ali, W.
Rehman, W. U.
Younas, M.
Ahmad, M. I.
Gul, S.
Powiązania:
https://bibliotekanauki.pl/articles/779416.pdf
Data publikacji:
2015
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
reverse osmosis (RO)
membrane separation
Total Dissolved Solids (TDS)
Total Coliform
E. Coli
Opis:
The present case study is focused on performance evaluation of a Reverse Osmosis (RO) membrane based pilot plant to treat the ground/surface drinking water sources polluted by flood, rivers and/or canals. The RO plant was designed, fabricated and then operated with polluted water. Two feed water samples having a TDS of 2.000 mg · L−1 and 10.000 mg · L−1 respectively, were taken and analyzed for physical, chemical and microbiological contaminants. The RO plant was run once through over a span of 100 hrs at an operating pressure of 15 bar. TDS rejections were found to be more than 94% while permeate flux was measured to be 25.82 L · m−2 · hr−1 to 40.55 L · m−2 · hr−1. Results show that RO plant has a potential to remove physical, chemical and microbiological contaminants like Total Coliform and E. Coli in one step.
Źródło:
Polish Journal of Chemical Technology; 2015, 17, 4; 42-48
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel synthesis of 3-(((E)-benzylidene)amino)-5-((Z)-3,4-dimethoxybenzylidene)-2-phenyl-3,5-dihydro-4H-imidazol-4-one derivatives as potent antimicrobial agents
Autorzy:
Manawar, Rohit B.
Parmar, Mukesh B.
Nayaka, Indresh J.
Pandit, Brinda H.
Shah, Manish K.
Powiązania:
https://bibliotekanauki.pl/articles/1066261.pdf
Data publikacji:
2019
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
4H-imidazol-4-one
A. niger
Anti-fungal
Anti-microbial Agent
Bioactivity
C. albicans
E. coli
Elemental analysis
IR spectroscopy
Mass spectroscopy
NMR spectroscopy
P. aeruginosa
S. aureus
S. pyogenes
Opis:
Novel synthesis of 4H-imidazol-4-one derivative by reaction of (Z)-3-amino-5-(3,4 dimethoxybenzylidene)-2-phenyl-3,5-dihydro-4H-imidazol-4-one with derivative of different aromatic aldehydes and Salicyldehyde. New synthesized compound are thermally stable and neither air-nor moisture sensitive at RT. Successive library of synthesized compound characterized using IR, NMR, Elemental, Mass, and its antimicrobial activity study.
Źródło:
World Scientific News; 2019, 130; 42-70
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mutator specificity of Escherichia coli alkB117 allele
Autorzy:
Nieminuszczy, Jadwiga
Janion, Celina
Grzesiuk, Elżbieta
Powiązania:
https://bibliotekanauki.pl/articles/1041261.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
lacZ → Lac+ reversion
mutational specificity
E. coli
MMS
alkB117
Opis:
The Escherichia coli AlkB protein encoded by alkB gene was recently found to repair cytotoxic DNA lesions 1-methyladenine (1-meA) and 3-methylcytosine (3-meC) by using a novel iron-catalysed oxidative demethylation mechanism that protects the cell from the toxic effects of methylating agents. Mutation in alkB results in increased sensitivity to MMS and elevated level of MMS-induced mutations. The aim of this study was to analyse the mutational specificity of alkB117 in a system developed by J.H. Miller involving two sets of E. coli lacZ mutants, CC101-106 allowing the identification of base pair substitutions, and CC107-CC111 indicating frameshift mutations. Of the six possible base substitutions, the presence of alkB117 allele led to an increased level of GC→AT transitions and GC→TA and AT→TA transversions. After MMS treatment the level of GC→AT transitions increased the most, 22-fold. Among frameshift mutations, the most numerous were -2CG, -1G, and -1A deletions and +1G insertion. MMS treatment appreciably increased all of the above types of frameshifts, with additional appearance of the +1A insertion.
Źródło:
Acta Biochimica Polonica; 2006, 53, 2; 425-428
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mismatch dependent uracil/thymine-DNA glycosylases excise exocyclic hydroxyethano and hydroxypropano cytosine adducts.
Autorzy:
Borys-Brzywczy, Ewa
Arczewska, Katarzyna
Saparbaev, Murat
Hardeland, Ulrike
Schär, Primo
Kuśmierek, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/1041473.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
base excision repair
E. coli mismatch uracil-DNA glycosylase
exocyclic cytosine adducts
human thymine-DNA glycosylase
S. pombe Thp1p glycosylase
Opis:
Exocyclic adducts of DNA bases, such as etheno- and hydroxyalkano- ones, are generated by a variety of bifunctional agents, including endogenously formed products of lipid peroxidation. In this work we selectively modified cytosines in the 5'-d(TTT TTT CTT TTT CTT TTT CTT TTT T)-3' oligonucleotide using: chloroacetaldehyde to obtain 3,N4-α-hydroxyethano- (HEC) and 3,N4-etheno- (εC), acrolein to obtain 3,N4-α-hydroxypropano- (HPC) and crotonaldehyde to obtain 3,N4-α-hydroxy-γ-methylpropano- (mHPC) adducts of cytosine. The studied adducts are alkali-labile which results in oligonucleotide strain breaks at the sites of modification upon strong base treatment. The oligonucleotides carrying adducted cytosines were studied as substrates of Escherichia coli Mug, human TDG and fission yeast Thp1p glycosylases. All the adducts studied are excised by bacterial Mug although with various efficiency: εC >HEC >HPC >mHPC. The yeast enzyme excises efficiently εC ł HEC >HPC, whereas the human enzyme excises only εC. The pH-dependence curves of excision of εC, HEC and HPC by Mug are bell shaped and the most efficient excision of adducts occurs within the pH range of 8.6-9.6. The observed increase of excision of HEC and HPC above pH 7.2 can be explained by deprotonation of these adducts, which are high pKa compounds and exist in a protonated form at neutrality. On the other hand, since εC is in a neutral form in the pH range studied, we postulate an involvement of an additional catalytic factor. We hypothesize that the enzyme structure undergoes a pH-induced rearrangement allowing the participation of Lys68 of Mug in catalysis via a hydrogen bond interaction of its ε-amino group with N4 of the cytosine exocyclic adducts.
Źródło:
Acta Biochimica Polonica; 2005, 52, 1; 149-165
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological air rating in a variety of objects during treatment of the post-slaughter poultry wastes Part I. Escherichia coli
Autorzy:
Oraibi, S. M.
Cybulska, K.
Powiązania:
https://bibliotekanauki.pl/articles/125448.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
E.coli
air
poultry waste facilities
composting
Opis:
The presence of Escherichia coli in the air of facilities involved in management and composting of post-slaughter poultry wastes in selected plants of West Western Pomerania region was studied. Measurements were made on four dates in a variety of weather conditions during the year. The study was conducted at 5 objects that differ in the type of waste and the degree of preparation for composting. These were: chemical treatment and preliminary processing plant, liquid wastes reservoir, platform for preparation of materials for composting, storage of biological sediments, and composting facility. Measurement of bacteria count was carried out in accordance with the applicable procedures on selective chromogenic TBX medium. The assays revealed the presence of E. coli at all test objects, but not always on all measurement dates. It has been shown that the presence of E. coli was from 20 to 3047 CFUm-3 of air, although the largest quantities were most frequently detected in the air of the building for post-slaughter waste pre-treatment in chemical treatment plant.
Źródło:
Journal of Ecological Engineering; 2016, 17, 5; 17-21
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies