Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "dual source" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Repetitive neurocontroller with disturbance feedforward path active in the pass-to-pass direction for a VSI inverter with an output LC filter
Autorzy:
Ufnalski, B.
Grzesiak, L. M.
Powiązania:
https://bibliotekanauki.pl/articles/200017.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
repetitive control
feedforward neural network
dynamic optimization problem
repetitive disturbance rejection
voltage source inverter
disturbance dual feedforward path
sterowanie powtarzalne
sieci neuronowe
problem optymalizacji dynamicznej
przetwornica napięcia
odrzucanie zakłóceń
Opis:
An enhancement to the previously developed repetitive neurocontroller (RNC) is discussed and investigated in the paper. Originally, the time-base generator (TBG) has been used to produce the only input signal for the neural approximator. The resulting search space makes the dynamic optimization problem (DOP) of shaping the control signal solvable with the help of a function approximator such as the feed-forward neural network (FFNN). The plant under consideration, i.e. a constant-amplitude constant-frequency voltage-source inverter (CACF VSI) with an output LC filter, is assumed to be equipped with the disturbance load current sensor to enable implementation of the disturbance feed-forward (pDFF) path as a part of the non-repetitive subsystem acting in the along the pass p-direction. An investigation has been undertaken to explore potential benefits of using this signal also as an additional input for the RNC to augment the approximation space and potentially enhance the convergence rate of the real-time search process. It is numerically demonstrated in the paper that the disturbance feed-forward path active in the pass-to-pass k-direction (kDFF) improves the dynamics of the repetitive part as well indeed.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 1; 115-125
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nieinwazyjne badania japońskiej XIX-wiecznej kadzielnicy z prowincji Satsuma przy użyciu dwuźródłowej tomografii komputerowej
Non-invasive analysis of the Japanese nineteenth century censer from the province of Satsuma using Dual Source Computed Tomography
Autorzy:
Mikołajska, Anna
Gurtat, Angelika
Urbańczyk-Zawadzka, Małgorzata
Banyś, Robert Paweł
Powiązania:
https://bibliotekanauki.pl/articles/168031.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
ceramika japońska
badania nieinwazyjne
rentgenografia
dwuźródłowa tomografia komputerowa DSCT
Japanese ceramics
non-invasive analysis
rentgenography
dual-source computed tomography DSCT
Opis:
Kadzielnica pochodzi z historycznej prowincji Japonii Satsuma (obecnie prefektura Kagoshima) i datowana jest na okres Meiji. Obiekt od grudnia 1945 r. znajduje się w zbiorach Muzeum Collegium Maius Uniwersytetu Jagiellońskiego, gdzie został przekazany ze składnicy wawelskiej. Kadzielnica wykonana jest z jasnej gliny, pokryta przezroczystą, delikatnie popękaną glazurą (krakle), ozdobiona bogatą polichromią, wykończona emalią i dekoracją brokatową. Na korpusie znajdują się cztery przedstawienia: postać Kannon, postacie dwóch taoistycznych mędrców, smok z trzema pazurami oraz dwa lwy Shishi. Są to najbardziej charakterystyczne elementy tej ceramiki. Brzusiec naczynia osadzony został na trzech prostych nogach z nasadami w formie głów lwa Shishi. Podczas prac przygotowawczych i konserwatorskich przy obiekcie zostały wykonane nieinwazyjne badania z wykorzystaniem promieniowania rentgenowskiego. W celu określenia stanu zachowania całego obiektu, a w szczególności trwałości łączeń korpusu i nóżek wykonano zdjęcia rentgenowskie oraz skany z wykorzystaniem dwuźródłowej tomografii komputerowej.
The censer comes from Japan, from the Meiji period, from the historical province of Japan Satsuma (now Kagoshima Prefecture). The object is in the collections of the Jagiellonian University Museum Collegium Maius, where it was transferred from the Wawel depot in December 1945. It is characterized by light clay and a transparent, slightly cracked glaze (crackles). It is decorated with rich and beautiful polychrome and finished with enamel and glitter decoration. There are four performances on the body: a dragon with three claws, the figure of Kannon, the figures of two Taoist wise men, two lions Shishi. These are the most characteristic elements of this ceramics. The censer is mounted on three legs depicting the head of the Shishi lion. Non-invasive X-ray examinations had been carried out before any conservation work of the presented object started. In order to assess the general condition of the whole object, in particular the durability of body and leg joints, X-ray and tomographic images were taken.
Źródło:
Szkło i Ceramika; 2019, R. 70, nr 1, 1; 4-7
0039-8144
Pojawia się w:
Szkło i Ceramika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray techniques in the investigation of a Gothic sculpture : the risen Christ
Autorzy:
Mikołajska, A.
Walczak, M.
Kaszowska, Z.
Urbańczyk-Zawadzka, M.
Powiązania:
https://bibliotekanauki.pl/articles/146866.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
cultural heritage
X-ray image
X-ray dual source computed tomography (DSCT)
scanning electron microscopy energy dispersed X-ray spectroscopy (SEM-EDX)
Opis:
For over a century, X-ray radiation has played an important role in the area of the conservation and restoration of cultural heritage objects. X-ray techniques are amongst the most fundamental and helpful methods used in the investigation of art works. This paper reviews the application of traditional radiography, X-ray dual source computed tomography (DSCT) and scanning electron microscopy combined with energy dispersed X-ray spectroscopy (SEM-EDX) to the investigation of a wooden, Gothic sculpture, The risen Christ. Thanks to the properties of X-ray radiation (different absorption by various materials) first two methods allow the assessment of the preservation state and the observation of the internal structure of an object in 3-D. While SEM-EDX analysis permits the elemental analysis of the polychrome layers. As a result 2-D and 3-D images, permitting the full volume inspection of an object, were taken in a totally non-destructive way. The morphological and physical information about the inner structure of the investigated wooden sculpture was obtained, revealing changes related to previous restorations, as well as ageing effects. Employing the SEM-EDX, painting materials (pigments and filers), were identified. Gained data is essential for restorers to understand the whole structure of the studied object and to decide which further investigation and restoration steps have to be undertaken.
Źródło:
Nukleonika; 2012, 57, 4; 627-631
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of a commercial high resistance bridge and methods to improve its precision
Autorzy:
Mihai, Iulian
Capra, Pier Paolo
Galliana, Flavio
Powiązania:
https://bibliotekanauki.pl/articles/2173898.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
high resistance measurements
dual source bridge
DSB
settle-time
measurement uncertainty
compatibility test
measurement noise
Opis:
At the National Institute of Metrological Research (INRIM) an evaluation of a commercial dual source high resistance bridge has been performed. Its two main measurement modes (single measurements and multiple measurements) have been investigated. The best settle time of a 10:1 measurement of high resistance ratio has been estimated to be about three times the time constant of the circuit involving the resistors. This constant, in turn, depends on the highest value resistor. By means of mathematical estimators, suitable numbers of the readings of the detector have been established in order to minimize noises. A compatibility test at 100 TΩ has shown that the best precision of the commercial bridge is achieved utilizing the multiple measurements mode with the auto update function. This mode also allows the characterization of a resistor as a function of the settle time. This characterization can be useful for the owner of the resistor who can request the laboratory to perform the calibration of the resistor with the settle time which is necessary for him.
Źródło:
Metrology and Measurement Systems; 2022, 29, 4; 701--718
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pracy systemu inercyjnej akumulacji energii w napędzie dwuźródłowym pojazdu miejskiego
Analyze of work the flywheel system accumulation energy in the two source drive in the city car
Autorzy:
Krakowiak, Ireneusz
Powiązania:
https://bibliotekanauki.pl/articles/253070.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
inercyjna akumulacja energii
napęd dwuźródłowy
pojazd
inertial energy accumulation
dual source drive
vehicle
Opis:
W artykule przedstawiono analizę pracy systemu inercyjnej akumulacji energii w napędzie dwuźródłowym pojazdu miejskiego. Dobrano przełożenia pośrednie pomiędzy współpracującymi elementami napędu i przełożenie główne przekładni planetarnej. Modele matematyczne opisujące dane komponentów umożliwiły opis pracy układu. Oszacowano zakresy zmian parametrów mechanicznych i elektrycznych poszczególnych komponentów napędu: momentów, mocy, napięć i prądów, przy spełnieniu założeń: identycznej prędkości bezwładnika i minimalnego wyładowania baterii elektrochemicznej po cyklu pracy. Wyznaczono sprawności energetyczne układu napędowego pracującego wg cyklu ECE w celu sprawdzenia opłacalności zastosowania takiego rozwiązania w lekkim pojeździe miejskim.
The paper describes the basic analyze of work the flywheel system accumulation energy in the city car of hybrid drive. There are selected ratios between components of hybrid drive and the planetary gear ratio. A full dynamic analysis was carried out by computer simulation methods, using original mathematical models of all the components of the drive system. There are determined parameters mechanical and electrical of components hybrid drive: speeds, torques, voltages, currents. The influence of the flywheel on the of effectiveness of energy battery utilization in has been presented. The influence of the planetary gear ratio value, the energetic capacity of electric battery and the flywheel on the battery state of change has also been determined. The limitations that come from constructional and exploitation features of the vehicle and it is drive have been analysed in adjusting parameters of the model.
Źródło:
TTS Technika Transportu Szynowego; 2015, 12; 1981-1985, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Augmented speed control scheme of dual induction motors with mutual flux angle control loop
Autorzy:
Kondratenko, Dmytro
Lewicki, Arkadiusz
Łuksza, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/27309952.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
dual-motor drive
induction motors
IMs
five-leg voltage source inverter
FLVSI
rotor angle control
sensorless control
Opis:
This paper proposes an augmented speed control scheme of dual induction motors fed by a five-leg voltage source inverter (VSI) with a common/shared-leg. An additional control loop is proposed here and based on the mutual flux angle – the difference between flux angular positions of the IMs. The main purpose of this research is to minimize the energy losses in the common inverter leg by controlling the mutual flux angle, at equal angular speeds of both motors. Simulation and experimental studies were carried out and the effectiveness of the proposed control method was proven. The PLECS software package was used for the simulation tests. The laboratory prototypewas prepared for the experimental validation. All results were provided and discussed in this paper.
Źródło:
Archives of Electrical Engineering; 2023, 72, 4; 915--930
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Primenenie lazernyh i optovolokonnyh tehnologij dlâ povyšeniâ èffektivnosti raboty sovremennyh optiče
The Application of Laser and Fibre-Optic Technologies for the Improvement of the Efficiency of Modern Optical Smoke Detectors
Zastosowanie technologii laserowych i światłowodowych w celu zwiększenia skuteczności pracy nowoczesnych optycznych czujek dymu
Autorzy:
Ivanov, Y. S.
Lushchik, A. P.
Kitsak, A. I.
Powiązania:
https://bibliotekanauki.pl/articles/373079.pdf
Data publikacji:
2018
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
dual fire sensor
point smoke detector
linear smoke detector
laser source
optical fibre
sensitivity
dualna czujka pożarowa
punktowa pożarowa czujka dymu
liniowa pożarowa czujka dymu
źródło laserowe
światłowód
wrażliwość
Opis:
Objective: The aim of the study is to demonstrate the possibility of increasing the sensitivity, resistance to electromagnetic interference and response speed of point smoke detectors on the basis of using laser processing and fibre optics technology. Project and methods: In order to achieve the above goal an optical point smoke detector was designed and produced. The detector uses a laser radiation source and fibre-optic communication line with a radiation receiver. Results: The combined laser-based fire alarm device which includes two smoke detection methods (controlling the intensity of radiation scattered by smoke particles and passed through the smoke without scattering) and carbon monoxide detector are produced. The tests of the fire detector to determine its basic functional parameters and the performance of detecting the test fire sources in accordance with standard SТB 16.03-2009. The minimum threshold quantity of optical smoke density detected in the control channel of the intensity of scattered radiation is 0.05 dB/m. The minimum threshold quantity of optical smoke density detected in the control channel of the intensity of radiation passing through the smoke without scattering is about 0.9 dB/m for controlled optical length 25 mm. The minimum concentration of carbon monoxide detection by the CO gas detector is 40 ppm. The testing results of combined laser-based fire alarm device on the detection efficiency of the standardised fire source bear record to its hypersensitivity for different types of smoke and a higher speed of detection of fires in comparison with single-channel point smoke detector. The tests of the combined laser fire detector to determine the efficiency of the fire detection model point to its increased sensitivity to different types of smoke and fire detection speed in comparison with a conventional single-channel point smoke detector. Using fibre optics for recording radiation getting through smoke without dissipation showed us the possibility of developing a point smoke detector on the linear principle of smoke detection with signal processing at a distance from the controlled zone in a well-screened box, for instance, inside a fire alarm control panel. Obviously, the signaling device will be highly resistant to electromagnetic interference due to the reliable screening of the sensitive elements of the electronic signal processing system and the lack of wiring connected to the fire alarm control panel. Conclusions: The advanced functional characteristics of the fire alarm device are provided thanks to the application of a laser source with a high intensity and a low divergence of radiation. The unique properties of laser radiation in the sensor’s structure made it possible to apply a number of design and technical solutions which provided a substantial increase in the sensitivity and fire detection rate of the sensor compared to the currently used traditional LED smoke detectors.
Cel: Celem pracy jest przedstawienie możliwości zwiększenia wrażliwości i odporności na interferencje elektromagnetyczne optycznych (punktowych) czujek dymu oraz poprawienia ich szybkości zadziałania poprzez zastosowanie technologii laserowych i światłowodowych. Projekt i metody: W celu osiągnięcia powyższego celu zaprojektowano i wyprodukowano optyczną punktową czujkę dymu wykorzystującą laserowe źródło promieniowania i połączenie światłowodowe z odbiornikiem promieniowania, a także przebadano jej charakterystyki użytkowe. Wyniki: Opracowano laserową czujkę dymu wykorzystującą dwie metody wykrywania dymu (kontrolę intensywności promieniowania rozproszonego cząsteczkami dymu oraz promieniowania przechodzącego przez dym bez rozproszenia) oraz czujnik tlenku węgla (CO). Przeprowadzono badania czujki mające na celu określenie jej podstawowych parametrów użytkowych oraz skuteczność wykrywania testowych źródeł pożaru zgodnie z normą STB 16.03-2009. Minimalna wartość progowa gęstości dymu wykrywana w komorze kontroli intensywności promieniowania rozproszonego wynosi 0,05 dB/m. Z kolei minimalna wartość progowa gęstości dymu w kanale kontroli intensywności promieniowania przechodzącego przez dym bez rozproszenia wynosi 0,9 dB/m przy kontrolowanej odległości 25 mm. Minimalne stężenie tlenku węgla, na które reaguje czujnik tlenku węgla to 40 ppm. Wyniki badań laserowej „łączonej” czujki pożarowej pod kątem skuteczności wykrywania przez nią testowych źródeł pożaru świadczą o jej zwiększonej wrażliwości na różne rodzaje dymu i szybszym wykrywaniu pożaru, w porównaniu ze standardową jednokanałową punktową czujką dymu. Zastosowanie światłowodów do rejestracji promieniowania przechodzącego przez dym bez rozproszenia wiązki pokazało, że możliwe jest opracowanie punktowej czujki dymu na jednej „liniowej” zasadzie wykrywania dymu i jednoczesne przetwarzanie sygnału w oddalonym od kontrolowanej strefy osłonionym bloku, na przykład wewnątrz centrali sygnalizacji pożarowej. Oczywiście, dzięki właściwej osłonie wrażliwych elementów układu elektronicznego przetwarzającego sygnał i rezygnacji z przewodów elektrycznych do połączeń z centralą, czujka tego typu będzie charakteryzowała się wysoką odpornością na zakłócenia elektromagnetyczne. Wnioski: Wysokie właściwości użytkowe czujki były możliwe do osiągnięcia dzięki zastosowaniu źródła laserowego o wysokiej intensywności i małej dywergencji promieniowania. Unikalne cechy promieniowania laserowego w konstrukcji czujki pozwoliły na zastosowanie wielu rozwiązań konstrukcyjnych i technicznych, które znacznie zwiększyły wrażliwość czujki i szybkość wykrycia pożaru w porównaniu z konwencjonalnymi diodowymi pożarowymi czujkami dymu.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2018, 49, 1; 86-92
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling hybrid powertrain operation of a wheeled vehicle including dual power source
Autorzy:
Banaś, W.
Kost, G.
Nierychlok, A.
Powiązania:
https://bibliotekanauki.pl/articles/99448.pdf
Data publikacji:
2011
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
hybrid powertrain
dual source
wheeled vehicle
Opis:
The paper presents a way of modeling hybrid drive system with a dual source of electricity. The use of such solution is to use better used and flow of energy in hybrid vehicle. Describes the sizing of electrochemical batteries per unit weight of a wheeled vehicle and the system was adopted to supporting the super-capacitor batteries. Presents a concept of switching multiple units in a hybrid system, which adopted the criterion of engine rotational speed and linear speed of the vehicle.
Źródło:
Journal of Machine Engineering; 2011, 11, No. 1-2; 152-161
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies