Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "droplet size" wg kryterium: Temat


Tytuł:
Forward angled spray: a method for improving the efficacy of herbicides
Autorzy:
Aliverdi, A.
Zarei, M.
Powiązania:
https://bibliotekanauki.pl/articles/2082750.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
droplet size
grassy species
non-vertical spray
wild barley
Opis:
It is challenging to obtain proper leaf wetting. An angled spray could overcome this impedi- ment, but which spray angle is best suited to droplet size is still unknown. In an outdoor pot experiment, seven doses of cycloxydim and sethoxydim were sprayed with single-orifice standard, anti-drift, and air induction (having a fine, medium, and extremely coarse spray quality, respectively) flat fan nozzles, using spray angles of 10°, 20° backward, 0° (vertical), 10°, 20°, 30°, 40°, 50°, and 60° forward relative to the direction of nozzle trajectory on wild barley at the three-leaf stage. Generally, the forward angled spray was better than the backward angled spray. With a standard flat fan nozzle, the forward angling of spray from 0° to 20° reduced the ED50 from 60.24 to 39.85 g a.i. ⋅ ha−1 for cycloxydim and from 150.51 to 81.13 g a.i. ⋅ ha −1 for sethoxydim. With an anti-drift flat fan nozzle, the forward angling of spray from 0° to 30° reduced the ED50 from 72.57 to 50.20 g a.i. ⋅ ha−1 for cycloxydim and from 181.94 to 104.51 g a.i. ⋅ ha−1 for sethoxydim. With an air induction flat fan nozzle, the forward angling of spray from 0° to 40° reduced the ED 50 from 102.96 to 45.52 g a.i. ⋅ ha −1 for cycloxydim and from 209.91 to 92.80 g a.i. ⋅ ha −1 for sethoxydim. More angling did not improve the efficacy of these herbicides. Our results revealed that larger spray droplets needed more spray angle than smaller spray droplets to achieve an equal control.
Źródło:
Journal of Plant Protection Research; 2020, 60, 3; 275-283
1427-4345
Pojawia się w:
Journal of Plant Protection Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ czasu mieszania na wielkość kropli w emulsjach na bazie oleju rzepakowego
Effect of mixing time on the droplet size in canola oil based emulsions
Autorzy:
Broniarz-Press, L.
Tarnicka, Z
Powiązania:
https://bibliotekanauki.pl/articles/2072346.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
środki powierzchniowo-czynne
wielkość kropel
emulsje
surfactants
droplet size
emulsions
Opis:
W pracy przedstawiono wyniki badań wpływu czasu mieszania na wielkość średnicy kropel w emulsjach wytworzonych na bazie oleju rzepakowego z dodatkiem niejonowych surfaktantów SPAN 20 i SPAN 80, które okazały się płynami Binghama. Średnica Sautera wzrasta w emulsjach wraz ze wzrostem udziału objętościowego oleju i maleje w miarę upływu czasu mieszania. Mniejsze wartości średnicy Sautera uzyskano dla układów z dodatkiem SPAN 80.
Research results dealing with mixing time effect on the droplet diamete in emulsions prepared on basis of canola oil with the addition of non-ionic surfactants SPAN 20 and SPAN 80 are presented in the paper. The emulsions used appeared to be Bingham fluids. The lower values of Sauter diameter were obtained for systems with the addition of SPAN 80.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 4; 293--295
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Do combinations of insecticides and acaricides influence spray droplet formation and the interaction with citrus leaves?
Autorzy:
Della Vechia, J.F.
Santos, R.T.
Griesang, F.
Santos, C.M.
Ferriera, M.C.
Andrade, D.J.
Powiązania:
https://bibliotekanauki.pl/articles/2084816.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
contact angle
coverage efficiency
droplet size
surface tension
tank mixture
Opis:
In agriculture, the mixing of pesticides in tanks is a common practice. However, it is necessary to previse possible physical-chemical implications of this practice, which may affect the efficiency of the treatments performed. Therefore, the objective of this study was to evaluate the effects of the addition of acaricide to insecticidal spray mixtures on the formation of spray droplets and the interaction with citrus leaves. The experimental design was totally randomized, in a (2 × 3 + 1) factorial scheme for seven treatments. Factor A corresponded to the spray mixture used (isolate or in the mixture). Factor B corresponded to the insecticides tested (lambda-cyhalothrin + thiamethoxam, phosmet, and imidacloprid) and the control consisted of a spray mixture with spirodiclofen only. Nine replications were performed for characterization of the spray droplet size spectrum and four replications for the analysis of the surface tension and the contact angle. The mixture of pesticides showed positive results in terms of application safety. The addition of acaricide to insecticide spray mixtures reduced the surface tension and contact angle of droplets on the adaxial surface of orange leaves. There was an increment in volume median diameter (VMD), a significant reduction in the volume of droplets with drift-sensitive size and improvement in the uniformity of droplet size. Therefore, the addition of acaricide to an insecticide spray mixture positively influenced spray droplet formation and the interaction with citrus leaves providing better coverage and droplet size fractions with an appropriate size for safe and efficient application.
Źródło:
Journal of Plant Protection Research; 2019, 59, 4; 487-493
1427-4345
Pojawia się w:
Journal of Plant Protection Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement and classification methods using the ASAE S572.1 reference nozzles
Autorzy:
Fritz, B.K.
Hoffmann, W.C.
Czaczyk, Z.
Bagley, W,
Kruger, G.
Henry, R.
Powiązania:
https://bibliotekanauki.pl/articles/66858.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
measurement method
classification method
droplet size
laser diffraction
reference nozzle
Opis:
An increasing number of spray nozzle and agrochemical manufacturers are incorporating droplet size measurements into both research and development. Each laboratory invariably has their own sampling setup and procedures. This is particularly true about measurement distance from the nozzle and concurrent airflow velocities. Both have been shown to significantly impact results from laser diffraction instruments. These differences can be overcome through the use of standardized reference nozzles and relative spray classification categories. Sets of references nozzles, which defined a set of classification category thresholds, were evaluated for droplet size under three concurrent air flow velocities (0.7, 3.1 and 6.7 m/s). There were significant, though numerically small, differences in the droplet size data between identical reference nozzles. The resulting droplet size data were used to categorize a number of additional spray nozzles at multiple pressure and air flow velocities. This was done to determine if similar classifications were given across the different airspeeds. Generally, droplet size classifications agreed for all airspeeds, with the few that did not, only differing by one category. When reporting droplet size data, it is critical that data generated from a set of reference nozzles also be presented as a means of providing a relative frame of reference.
Źródło:
Journal of Plant Protection Research; 2012, 52, 4
1427-4345
Pojawia się w:
Journal of Plant Protection Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody poprawy efektywności procesu rozpylania w nebulizatorach pneumatycznych
Methods to improve the efficiency of atomization process in pneumatic nebulizers
Autorzy:
Matuszak, M.
Ochowiak, M.
Włodarczak, S.
Powiązania:
https://bibliotekanauki.pl/articles/2073238.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
rozpylanie
średnia średnica kropli
widmo rozpylenia
nebulizator
atomization
mean droplet diameter
droplet size distribution
nebulizer
Opis:
Omówiono metody poprawy efektywności procesu rozpylania w nebulizatorach pneumatycznych. Skupiono się na podniesieniu temperatury rozpylanej cieczy oraz dodatkowym napowietrzaniu cieczy w naczyńku nebulizacyjnym. Połączenie tych dwóch efektów w znaczący sposób przyczyniło się do zmniejszenia średniej średnicy kropli, a charakter aerozolu stał się bardziej monodyspersyjny. Ponadto określono wpływ objętościowego natężenia przepływu gazu na proces atomizacji.
The paper discusses methods to improve the efficiency of atomization process in pneumatic nebulizers. The studies were directed on increasing the temperature of sprayed liquid and additional aeration of liquid in the nebulizer cup. Combination of these two effects significantly contributes to the decrease of mean droplet diameter and simultaneously the character of aerosol becomes more monodisperse. In addition, the effect of gas volumetric flow rate on the atomization process was determined.
Źródło:
Inżynieria i Aparatura Chemiczna; 2017, 3; 90--91
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Instrument wirtualny do oceny poprzecznego rozkładu rozpylonej strugi w opryskiwaczach rolniczych
Virtual instrument to evaluation of atomized stream crosswise distribution in agricultural sprayers
Autorzy:
Kuna-Broniowski, M.
Plichta, D.
Powiązania:
https://bibliotekanauki.pl/articles/288231.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
wizualizacja
pomiar
wielkość drobin
opryskiwacz rolniczy
visualization
measurement
droplet size
agricultural sprayer
Opis:
Przedstawiono sposób prezentacji oraz analizy wyników pomiaru wielkości kropli metodą elektrostatyczną. Dokonano opracowania graficznej reprezentacji rozkładu wielkości kropli pochodzących ze zatomizowanej strugi cieczy. Dane pomiarowe rejestrowano i analizowano za pomocą wirtualnego instrumentu pomiarowego, który umożliwiał przeprowadzenie analizy w czasie rzeczywistym. Uzyskane wyniki przedstawiono na planach (wykresach barwnych) oraz wykresach rozkładu poprzecznego. Ten sposób prezentacji umożliwia bardzo szybką i intuicyjną ocenę otrzymanych wyników pomiaru odnośnie wielkości i liczby kropli pochodzących ze zatomizowanej strugi cieczy. Ponadto wykorzystanie technologii informatycznej pozwoliło na szybkie wyznaczenie charakterystyk statystycznych.
Paper described the manner of presentation and measuring results’ analysis of droplet size by using an electrostatic method. Pictorial representation of the droplet size distribution in atomized liquid stream was also elaborated. The measurement data were recorded and analyzed by means of a virtual measuring instrument that enabled to make an analysis within real time. Obtained results were presented on colored diagrams (plans) and lateral distribution diagrams. Such a manner of presentation makes possible fast and intuitional evaluation of obtained measurement results relating the size and number of droplets from atomized liquid stream. Moreover, the use of information technology enabled fast determination of statistical characteristics.
Źródło:
Inżynieria Rolnicza; 2005, R. 9, nr 8, 8; 197-202
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Droplet size classification of air induction flat fan nozzles
Autorzy:
Czaczyk, Z.
Kruger, G.
Hewitt, A.
Powiązania:
https://bibliotekanauki.pl/articles/65996.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
droplet size
spray classification
air induction nozzle
flat fan nozzle
working parameter
Opis:
Measurements were made of the droplet size for a series of air induction flat fan nozzles produced by Marian Mikołajczak Agro Technology (MMAT) and Coorstek. The MMAT nozzles, according to International Organization for Standardization (ISO) standard sizes, are typical single jet (long body, 37 mm) with 025, 03, and 04 orifice sizes; (short body, 21 mm) with 02, 025, 03 and 04 orifice sizes; and twin jet (short body, 21 mm) with 03 and 04 orifice sizes. Ceramic air induction flat fan nozzles of the Albuz AVI series (Coorstek, France) with the orifice size 01, 02 and 03 were tested. The sprays were described using the following droplet size parameters: Dv10, Dv50, Dv90, relative span (RS), spray volume (%) in size fractions < 100 μm and 100÷200 μm. The sprays were also classified according to American Society of Agricultural Engineers (ASAE) standard S572.1 (ASAE 2009).
Źródło:
Journal of Plant Protection Research; 2012, 52, 4
1427-4345
Pojawia się w:
Journal of Plant Protection Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model based decision support system of operating settings for MMAT nozzles
Autorzy:
Fritz, B.K.
Czaczyk, Z.
Hoffmann, W.C.
Powiązania:
https://bibliotekanauki.pl/articles/65707.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
droplet size
classification
determination
spraying
modelling
sprayer operating setting
decision support system
Opis:
Droplet size, which is affected by nozzle type, nozzle setups and operation, and spray solution, is one of the most critical factors influencing spray performance, environment pollution, food safety, and must be considered as part of any application scenario. Characterizing spray nozzles can be a timely and expensive proposition if the entire operational space (all combinations of spray pressure and orifice size, what influence flow rate) is to be evaluated. This research proposes a structured, experimental design that allows for the development of computational models for droplet size based on any combination of a nozzle’s potential operational settings. The developed droplet size determination model can be used as Decision Support System (DSS) for precise selection of sprayer working parameters to adapt to local field scenarios. Five nozzle types (designs) were evaluated across their complete range of orifice size (flow rate*) and spray pressures using a response surface experimental design. Several of the models showed high level fits of the modeled to the measured data while several did not as a result of the lack of significant effect from either orifice size (flow rate*) or spray pressure. The computational models were integrated into a spreadsheet based user interface for ease of use. The proposed experimental design provides for efficient nozzle evaluations and development of computational models that allow for the determination of droplet size spectrum and spraying classification for any combination of a given nozzle’s operating settings. The proposed DSS will allow for the ready assessment and modification of a sprayers performance based on the operational settings, to ensure the application is made following recommendations in plant protection products (PPP) labels.
Źródło:
Journal of Plant Protection Research; 2016, 56, 2
1427-4345
Pojawia się w:
Journal of Plant Protection Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chlorpyrifos Removal from Aqueous Solutions by Emulsion Liquid Membrane: Stability, Extraction, and Stripping Studies
Autorzy:
Al-Damluji, Farrah Emad
Mohammed, Ahmed A.
Powiązania:
https://bibliotekanauki.pl/articles/2202325.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
emulsion liquid membrane
chlorpyrifos
emulsion droplet size
stability
mass transfer coefficient
extraction efficiency
Opis:
The current paper focuses on assessing key parameters affecting the extraction of Chlorpyrifos as well as emulsion stability using the emulsion liquid membrane technology. Five parameters affecting the extraction have been studied: homogenizer speed, emulsification time, agitating time, surfactant concentration, and stripping phase concentration taking into consideration the emulsion breaking. Experiments proved that using the resulting optimum values will maximize both extraction and stripping efficiencies (93.8% and 94.7% respectively), while minimizing the emulsion breakage (increasing the stability of emulsion) to 0.73% with no need to employ a carrier agent. A 10 min agitating time, 3% (v/v) Span 80 as a surfactant, 12700-rpm homogenizer speed, 0.25 M HCl as an internal phase concentration, and 5 min emulsification time are chosen to be the optimum parameters’ values. A study of extraction kinetics and estimation of mass transfer coefficient was also accomplished (3.89×10-9m/s). The conclusions of this work can be extended to the removal of other types of pesticides from water.
Źródło:
Journal of Ecological Engineering; 2023, 24, 2; 101--111
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical Simulations of the Effects of Droplet Size and Concentration on Vapour-Droplet JP-10/Air Detonations
Autorzy:
Liu, L.
Zhang, Q.
Powiązania:
https://bibliotekanauki.pl/articles/358150.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
multiphase detonation
discrete phase model
evaporation and breakup model
droplet size effect
initial concentration effect
Opis:
Two-dimensional simulations were conducted for JP-10 mono-dispersed vapour-droplet detonation in air, based on the detonation mechanism for clouds and validation of the extending critical droplet size limits in previous tests. In the simulations, the discrete phase model combined with the droplet evaporation and droplet breakup models was used. Utilizing a wide range of mono-dispersed droplet sizes and initial droplet concentrations, all cases of JP-10 droplets with a certain amount of pre-vaporized fuel can successfully achieve the deflagration to detonation transition. Detonation velocities at the equivalent concentration with droplet diameters no larger than 50 μm are in good agreement with the theoretical detonation velocities. The effects of droplet size and initial droplet concentration on the detonation behaviour were also investigated. Detonation velocities attained with droplet diameters below 50 μm appear to decrease very slightly with droplet size, but are almost equal to the velocity in gases. When the droplet diameter is above 50 μm, there is a decrease in simulated detonation velocity compared with fine droplets, and no secondary pressure peak was observed. For fuel-rich combustion, detonation velocities decrease rapidly with an increase in initial droplet concentration, and post-wave pressure fluctuation was obviously irregular, caused by the secondary local explosion of the droplets.
Źródło:
Central European Journal of Energetic Materials; 2018, 15, 1; 175-190
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność herbicydów w uprawie kukurydzy w zależności od doboru adiuwantów i rozpylaczy
Effect of spray nozzle type and adjuvants on herbicide activity in maize
Autorzy:
Kierzek, R.
Wachowiak, M.
Krawczyk, R.
Ratajkiewicz, H.
Powiązania:
https://bibliotekanauki.pl/articles/238241.pdf
Data publikacji:
2014
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
opryskiwanie
adiuwanty
herbicydy
kukurydza
chwast
rozpylacz
spraying
adjuvants
herbicide
maize
weeds
droplet size
nozzle type
Opis:
W badaniach polowych określano wpływ środków powierzchniowo czynnych, dodawanych do cieczy użytkowej zawierającej herbicydy Hector 53,6 WG lub Hector Max 66,5 WG, na skuteczność zwalczania komosy białej w uprawie kukurydzy. Oceniano ponadto wpływ rozpylaczy o identycznej intensywności wypływu cieczy (w dm3·min-1), lecz wytwarzających krople o zróżnicowanej wielkości (jakość rozpylenia cieczy), na efektywność chwastobójczą. W zmiennych warunkach meteorologicznych panujących przed zabiegami ochronnymi i w trakcie ich wykonywania, dobór adiuwantów i rozpylaczy wpływał na skuteczność działania herbicydów. W warunkach stabilnych najlepsze efekty zniszczenia komosy białej (gatunek trudno zwilżalny) uzyskano po wykonaniu opryskiwania za pomocą rozpylaczy dwustrumieniowych TwinJet TJ60 11002 VS, wytwarzających krople drobne i bardzo drobne, natomiast w warunkach zmiennych i stresu wodnego – lepszym rozwiązaniem było użycie do zabiegu rozpylaczy grubokroplistych (AVI 11002), gdy do herbicydów dodawano adiuwanty o cechach poprawiających retencję oraz wnikanie substancji czynnych przez warstwę woskową liści. Najbardziej efektywnym dodatkiem okazał się adiuwant olejowy Olstick 90 EC.
The droplet size used for spraying operations and spray liquid properties modified with adjuvants have a significant impact on the coverage of the leaf surface of weeds and protected plants. In the study the effect of nozzle types with the same output but with different spray qualities (droplet size) was tested. Also was evaluated the influence of surface active agents (adjuvants) added to herbicide in tank mixture against Chenopodium album L. control in maize. Depending on weather conditions prevailing during the period of protective treatments (variable structure of weed leaf surface), the impact of spraying techniques and adjuvants on herbicidal effectiveness were mixed. The results showed that the most effective weed control was achieved after treatment with a fine nozzles TwinJet TJ60 11002 VS, especially when the adjuvants were added to herbicides to increase retention and penetration of active ingredients through a wax layer on the Ch. album leaves. In variable weather conditions the most useful was an adjuvant oil Olstick 90 EC.
Źródło:
Problemy Inżynierii Rolniczej; 2014, R. 22, nr 2, 2; 29-39
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu warunków powstawania aerozoli w elektronicznych papierosach na ich właściwości fizykochemiczne
Determination of formation conditions’ influence on physicochemical properties of electronic cigarettes aerosols
Autorzy:
Odziomek, M.
Kwiatkowski, Ł.
Sosnowski, T. R.
Powiązania:
https://bibliotekanauki.pl/articles/2073275.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
aerozol
e-papierosy
rozkład wielkości kropel
parowanie
kondensacja
aerosol
e-cigarettes
droplet size distribution
evaporation
condensation
Opis:
Celem pracy było zbadanie procesów odpowiedzialnych za powstawanie i właściwości aerozoli uwalnianych z elektronicznych papierosów. Wykorzystując dyfraktometr laserowy określono podstawowe parametry objętościowego rozkładu wielkości kropel aerozolu uwalnianego z czterech modeli e-papierosów różniących się wewnętrznym oporem aerodynamicznym. Aerozole zostały wytworzone w warunkach odpowiadającym fizjologicznym wartościom przepływu powietrza z płynów zawierających składniki powszechnie występujące w e-liquidach. Stwierdzono, że jakość uwalnianego aerozolu zależy przede wszystkim od konstrukcji urządzenia, ale także od składu i właściwości e-liquidów.
The aim of this work was to investigate the processes responsible for generation and properties of aerosols released from electronic cigarettes. Based on the laser diffraction method the primary parameters of droplet size distribution of aerosols released from four e-cigarette models with different internal aerodynamic resistance were determined. Aerosols were generated at physiological flow rates from e-liquids with different composition and properties. It was stated that the quality of aerosol depends mainly on device construction but it is also related to e-liquid composition and properties.
Źródło:
Inżynieria i Aparatura Chemiczna; 2017, 4; 134--135
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of turbiscan lab to study the effect of emulsifier content on the stability of plant origin dispersion
Autorzy:
Zalewska, Anna
Kowalik, Joanna
Grubecki, Ireneusz
Powiązania:
https://bibliotekanauki.pl/articles/185345.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
emulsion
polysorbate 80
backscattered light
droplet size
stability
emulsja
polisorbat 80
rozproszone światło
rozmiar kropli
stabilność
Opis:
The effect of emulsifier volume on emulsion system stability of plant origin being the basis of diet supplements for animals in winter season was analyzed. For this purpose, measurements of the backscattered light intensity as the function of the measuring cell height were conducted with a Turbiscan LAB optical analyzer. System stability was analyzed on the basis of Turbiscan Stability Index values. A Helos laser analyzer and a Nikon Eclipse E400 POL optical microscope were used to investigate drop size distribution and analyze microscopic pictures. It was shown that emulsion with 10% (w/w) of the emulsifier was the most stable one.
Źródło:
Chemical and Process Engineering; 2019, 40, 4; 399--409
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hydrocyklony do rozdziału układu ciecz - ciecz
Hydrocyclones for liquid - liquid separation
Autorzy:
Gutteter-Grudziński, J.M.
Powiązania:
https://bibliotekanauki.pl/articles/2070688.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
hydrocyklon
separacja emulsji o/w
wielkość kropel
hydrocyclone
separation of oil-in-water emulsions
droplet size
Opis:
Hydrocyklony powszechnie stosowane są do zagęszczania cząstek stałych np. mułów. W ostatnim czasie podjęto próby rozdziału emulsji O/W np. na platformach wiertniczych. W artykule przedstawiono oryginalne wyniki badań autora nad rozdziałem emulsji olejowo-wodnej. Przedstawiono teorię sedymentacji kropel oleju w hydrocyklonie oraz wyniki obliczeń i pomiarów średnicy kropel oleju miernikiem firmy Malvern.
Hydrocyclones are commonly used for compacting solid particles, e.g. sediments. Recent attempts to separate homogenous phases from oil/water emulsions have an environmental background, as relevant oil-water separation installations seem to have various applications, e.g. in oil platforms during uncontrolled spills. This article presents original results of author's own research on the separation of oil and water from emulsions. The concept of oil droplets" sedimentation in a hydrocyclone is discussed and the results of calculations and measurements of oil droplet diameter using the Malvern particle analyzer are shown.
Źródło:
Inżynieria i Aparatura Chemiczna; 2009, 5; 34-35
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ lepkości cieczy na proces rozpylania w inhalatorach medycznych
Effect of viscosity on the atomization process in medical inhalers
Autorzy:
Broniarz-Press, L.
Ochowiak, M.
Markuszewska, M.
Włodarczak, S.
Powiązania:
https://bibliotekanauki.pl/articles/2072505.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
inhalator
rozpylanie
widmo rozpylenia
lepkość
średnica Sautera
inhaler
atomization
viscosity
droplet size histogram
Sauter mean diameter
Opis:
W pracy przedstawiono wyniki badań rozpylania wody oraz wodnych roztworów gliceryny w inhalatorze medycznym. Przeprowadzono analizę wpływu lepkości na wielkość kropel, ich rozkłady ilościowe oraz średnią średnicę kropli. Stwierdzono, że lepkość w istotny sposób wpływa na wielkości zastępczej średnicy kropli. Wykazano także, że ze wzrostem stężenia gliceryny wzrasta udział kropel o większych średnicach, a widmo rozpylenia ulega rozszerzeniu.
Research results dealing with atomization of water and aqueous solutions of glycerol in a medical inhaler are presented in the paper. Analysis of influence of viscosity on the droplet size, droplet size histograms and mean droplet diameter was carried out. It was proved that viscosity affected significantly the droplet size diameter. For higher glycerol concentration, the fraction of droplets with a larger diameter increases and the droplet size histogram ii wider.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 4; 291--292
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies