Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "dosimeter" wg kryterium: Temat


Wyświetlanie 1-13 z 13
Tytuł:
Tartrazine Solution as Dosimeter for Gamma Radiation Measurement
Autorzy:
Gobara, M.
Baraka, A.
Powiązania:
https://bibliotekanauki.pl/articles/412328.pdf
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
gamma radiation
degradation
sensitivity
tartrazine
dosimeter
Opis:
In this study, Tartrazine aqueous solution was investigated as a simple low-dose dosimeter in the range of 20-500 Gy for the high ionizing radiation, gamma ray. Gradual bleaching of Tartarzine solution was observed with dose by measuring the absorbance of Tartarzine-solutions at specified wavelength, λmax = 428 nm. Tartrazine concentration (10–4, 5 ×10–4 and 10–3 M) and solution-initial pH value (5, 7 and 9) were considered as factors affecting degree of bleaching. It was found that Tartarzine-solution color was diminished gradually with selected dose range due to breakdown of the azo bond. The rate of bleaching increases with the increase of solution-initial pH. Increase of Tartarzine-concentration causes widening of range to which solution is susceptible. The post-irradiated effect (24 hours) was found to cause more bleaching. The sensitivity of Tartrazine solution is not regular with the Tartarzine-concentration and regular with pH.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2014, 14, 1; 106-117
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie folii PTFE jako sensora promieniowania-ALFA
Applications of PTFE foil as a sensor Alpha-radiation
Autorzy:
Gubański, A.
Kupracz, J.
Powiązania:
https://bibliotekanauki.pl/articles/160168.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
elektret
dozymetr elektretowy
radon
electret
electrets dosimeter
Opis:
Zastosowanie elektretu w dozymetrze, wykorzystuje efekt kompensacji dodatniego ładunku zgromadzonego na elektrecie w wyniku oddziaływania promieniowania jonizującego z powietrzem. Jony ujemne, powstałe w wyniku działania promieniowania wewnątrz komory jonizacyjnej, kompensują dodatni ładunek elektretu. Pomiar ładunku próbki elektretowej, zastosowanej jako sensor, przed ekspozycją, oraz bezpośrednio po, pozwala ocenić stężenie czynnika wywołującego zagrożenie promieniotwórcze w badanym środowisku. Jednym z największych zagrożeń radiologicznych dla człowieka jest radon. Ocenia się że, wdychanie pochodnych radonu w pomieszczeniach mieszkalnych, gdzie typowe stężenie (200 Bq/m3

) jest dziesięciokrotnie większe, niż na zewnątrz budynków (20 Bq/m3

) stanowi główną przyczynę zagrożenia radiacyjnego dla człowieka. Przyczepione do cząsteczek aerozoli pochodne radonu, Po218

, oraz Po214

, osadzają się na ściankach oskrzeli gdzie emitują cząstki alfa o energiach 6,0 MeV i, 7,69 MeV. Energia cząsteczek alfa jest wystarczająca do napromieniowania komórek podstawowych oskrzeli i płuc. Detekcja cząsteczek alfa i pomiar ich stężenia w badanym środowisku pozwala na ocenę narażenia ludzi na wdychanie pochodnych radonu. Wykorzystanie elektretu w konstrukcji dozymetru jako sensora promieniowania alfa, wymaga opracowania metody formowania elektretów, pozwalającej na uzyskanie stabilnych parametrów (czasu życia), tak aby zanik ładunku elektretu był głównie uwarunkowany promieniowaniem radiacyjnym, przy pomijalnym wpływie warunków otoczenia.

The application of an electret in the construction of an dosimeter is based on the compensation of positive charge in the sensor. The compensation is achieved as a result of reaction between radiation and air molecules. Negative ions produced inside the ionization chamber are collected on the positively charged electret, compensate the positive electret charge. The measurement of the depleted charge before and during the radiation exposure period helps to estimate the concentration of dangerous substances the in the particular environment. The greatest radiological threat for humans among all natural sources is imposed by Radon. It is assumed that half of the humans disposure to radiation is a result of breathing radon derivatives. In buildings the average concentration is ten times higher (200 Bq/m3

) than outdoors (20 Bq/m3

). The radon derivatives 218

Po and  214

Po stick to aerosols and breathed settle on gills tissues. Radon emits alfaparticles with the energies 6,0 MeV, 7,69 MeV. This energy is sufficient to irradiate the cells in lungs and gills. Detection of alfa-particles and measurement of its concentration in particular environment enables the risk assessment of the radon exposure of humans. The application of electret in the dosimeter as a sensor of alfaparticles needs a further research on electret formation. This process should end with stable parameters of the sensor which must be sensitive to the radon and robust against environmental influences.
Źródło:
Prace Instytutu Elektrotechniki; 2012, 259; 67-68
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dosimetric characteristics of active solid state detectors in a 60 MeV proton radiotherapy beam
Autorzy:
Sowa, U.
Nowak, T.
Michalec, B.
Mierzwińska, G.
Swakoń, J.
Olko, P.
Powiązania:
https://bibliotekanauki.pl/articles/146780.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
diamond dosimeter
diode Si
dosimetry
proton beam
Opis:
Several solid state detectors, such as dosimetric diodes, MOSFET detectors or diamond detectors are used for quality control of radiotherapy beams. The goal of this work was to determine dosimetric properties of the PTW diamond detector (DD) and the PTW silicon diode in the 60 MeV therapeutic beam (practical range in water Rp = 29.17 mm) located at the Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN, Kraków). A PTW Markus ionization chamber was used as a reference device. The empirical correction factor for diamond detector, kDD(Rresidual), introduced in the Technical Report Series of IAEA, TRS-398 [9] as a function of beam quality, Rresidual, was found to decrease from 1.12 for Rresidual = 1.5 mm to 1.04 for Rresidual = 26 mm. The reproducibility of response of DD and PTW diodes in the proton filed did not exceed 0.11%. Our results show that diamond detectors and dosimetric diodes are useful tools for quality assurance (QA) of therapeutic proton beam, but each type of detectors has specific properties which should be taken into account when choosing particular application.
Źródło:
Nukleonika; 2012, 57, 4; 491-495
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of the pre-irradiation storage procedure on the dose response of a Fricke xylenol orange gel dosimeter
Autorzy:
Liosi, G. M.
Giacobbo, F.
Pignoli, E.
Carrara, M.
Gambarini, G.
Mariani, M.
Powiązania:
https://bibliotekanauki.pl/articles/147138.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radiation dosimetry
Fricke-gelatin-xylenol orange dosimeter
optical absorbance measurement
Opis:
The Fricke xylenol orange (FX) gel system is a chemical dosimeter characterized by good sensitivity, linear dose response, tissue equivalence, no toxicity, easy preparation, reproducibility and low cost. Thanks to the presence of the gelatinous matrix, the system is particularly suitable to perform reliable 3D mapping of the absorbed dose spatial distribution via magnetic resonance imaging (MRI) or optical techniques. The aim of this work is to study in a systematic way the influence of the pre-irradiation storage procedure upon sensitivity, dose response stability and lifetime of use of a FX gel system made with gelatin from porcine skin subjected to homogeneous irradiation. For this purpose, different pre-irradiation storage procedures, in terms of temperature and duration of each storage step, were investigated. In order to evaluate the dose response stability, the optical analyses of the samples were performed up to 6 hours after irradiation. Moreover, the samples were irradiated at time intervals of 24 hours for up to 7 days after preparation in order to evaluate the system lifetime of use. Regardless of their thermal and temporal life, the samples show linear dose responses in the investigated dose range (3–24 Gy) and an increase of sensitivity with the time elapsed between preparation and irradiation. Among the three pre-irradiation storage procedures considered here, a procedure that provides the best dose response stability and lifetime of use was identifi ed and recommended for further use. The analyzed dosimetric system possesses good properties that make it promising for medical application, particularly concerning the evaluation of pre-treatment plan quality assurance within the conformational external beam radiotherapy.
Źródło:
Nukleonika; 2015, 60, No. 3, part 2; 603-607
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bone powder as EPR dosimetry system for electron and gamma radiation
Autorzy:
Ziaie, F.
Hajiloo, N.
Fathollahi, H.
Mehtieva, S. I.
Powiązania:
https://bibliotekanauki.pl/articles/148156.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
bone powder dosimeter
EPR response
dose rate
electron beam
gamma ray
Opis:
In this work bovine bone powder samples were irradiated at three different dose rates of 100, 260 and 630 kGy/min for the absorbed dose range of 3 to 110 kGy, using 10 MeV electron beam radiation. The samples were subjected to EPR measurement at room temperature in air. The variation of EPR signal intensities were constructed and evaluated base on quantitative data related to the absorbed doses. Moreover, they were compared with the obtained results from the samples irradiated by a 60Co gamma-ray source with a dose rate of 2.65 kGy/h. The time and temperature effects on the EPR response of this dosimeter were also studied. The results indicated that the bone sample was a suitable dosimeter especially for electron beam at high doses.
Źródło:
Nukleonika; 2009, 54, 4; 267-270
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stability study of free radicals in 10 MeV electron beam irradiated quartz as an EPR dosimetry method
Autorzy:
Ziaie, F.
Mohammadzadeh, A.
Modarresi, M.
Powiązania:
https://bibliotekanauki.pl/articles/148163.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
quartz dosimeter
EPR response
dose rate
electron beam
EPR signal stability
Opis:
In this work the stability of free radicals induced by a 10 MeV electron beam in quartz samples was studied. The investigations have been done for different doses and different dose rates. For this reason, quartz samples in powder form were irradiated at different dose rates, i.e. 100, 260 and 630 kGy/min for absorbed dose range of similar to 5–80 kGy using the 10 MeV electron beam radiation. The dose values were validated using a polystyrene calorimeter system as a reference standard dosimetry system. The EPR optimum system parameters were defined and EPR responses at room temperature in air were measured and compared. The EPR signal, which is due to the free radicals induced by electron beam, was also investigated at different time intervals to check its stability. The main objective of this work was to study the feasibility of using quartz as a dosimeter. Thus, the variation of EPR signal intensities with the absorbed dose values were evaluated and plotted in a graph. The results show that the variation of dose rate, do not affect considerably the EPR response.
Źródło:
Nukleonika; 2009, 54, 4; 251-254
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dosimetric properties of gammaand electron-irradiated commercial window glasses
Autorzy:
Fuochi, P.
Corda, U.
Lavalle, M.
Kovács, A.
Baranyai, M.
Mejri, A.
Farah, K.
Powiązania:
https://bibliotekanauki.pl/articles/146494.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
silicate glass
gamma rays
electron beam
optical absorption
dosimeter
fading behaviour
Opis:
Two different types of window glasses have been investigated as possible routine dosimeters in the range of 1-50 kGy. Glass samples were irradiated with 3.4 MeV and 8.4 MeV electron beams and the results compared with those obtained by 60Co gamma irradiation. Due to the strong optical absorption at wavelengths ess than 310 nm, even at low doses, optical measurements were limited to the range 320-700 nm. In both types of glasses, irradiation induced two absorption bands around 410 and 600 nm the intensities of which are proportional to dose; the 600 nm band being less sensitive to radiation. These bands have been attributed to non bridging oxygen hole centres existing in two different configurations. Because of the rapid fading of the optical absorbance observed at room temperature immediately after irradiation (greater than 15% in two days), the samples underwent a post-irradiation thermal treatment (150 graduate C for 20 min) to improve the stability of absorbance. The fading characteristics of the irradiated and thermally treated glasses, kept in the dark at room temperature, were studied for several weeks. A fast decay, whose intensity depends on the type and energy of the ionizing radiation, was observed for few days after irradiation and thermal treatment, followed by a much slower decay. The results show that this kind of material could be used as routine dosimeters within a certain dose range, as long as proper calibrations are made for each batch of glass and the appropriate precautions are taken when doing calibration and performing routine dosimetry.
Źródło:
Nukleonika; 2009, 54, 1; 39-43
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The radon dosimeter combining charcoal canisters and TLD detectors type MCP-N (LiF: Mg, Cu, P)
Dawkomierz radonowy z węglem aktywnym wyposażony w detektory termoluminescencyjne typu MCP-N (LiF: Mg, Cu, P)
Autorzy:
Bogacz, J.
Budzanowski, M.
Haber, R.
Powiązania:
https://bibliotekanauki.pl/articles/340158.pdf
Data publikacji:
2004
Wydawca:
Główny Instytut Górnictwa
Tematy:
dozymetria radonowa
detektor termoluminescencyjny
dawkomierz radonowy
radon dosimetry
thermoluminescent detector
radon dosimeter
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2004, 1; 49-50
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of noise sources and selection of ear protector in a coal mine
Autorzy:
Erol, Ilknur
Su, Okan
Powiązania:
https://bibliotekanauki.pl/articles/2203335.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kopalnia węgla
hałas
dozymetr
coal mine
noise
sound meter
dosimeter
hearing protection device
Opis:
In this study, the noise sources to which a coal miner, who works at the Kurul panel of Kilimli Colliery, Zonguldak, was exposed were investigated. These sources were positioned at different points from the surface to the workface. Noise levels were measured according to the working periods of the coal miners around the machines. The results were evaluated under the Turkish Noise Regulation. The critical exposure times in which the coal miners could work without the use of personal protective equipment were examined according to the noise values to which they were exposed. In addition, the personal noise exposure values of the machine operators (boring machine, electro-hydraulic drill, and pick hammer) were determined during the development works. Two different types of noise measurements, with a microphone at the ear level and inside the ear protector, were conducted. The results obtained when the microphone of the personal dosimeter was at ear level, were found to be 15 dBA higher than those when the microphone was inside the ear protector. As a result, the selection methods of ear protectors were analyzed. Recommendations were given for those working on the risky tasks at the panel.
Źródło:
Archives of Mining Sciences; 2022, 67, 3; 455--476
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przyrządy dozymetryczne produkowane dla ludności po katastrofie w Czarnobylu
Dosimetry equipment produced for popular use after Chernobyl disaster
Autorzy:
Karolewski, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2055827.pdf
Data publikacji:
2022
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dozymetria
dozymetr
licznik Geigera
radiometr
indykator promieniowania
Czarnobyl
skażenie radioaktywne
dosimetry
dosimeter
Geiger counter
radiometer
radiation indicator
Chernobyl
radioactive contamination
Opis:
Do czasów katastrofy w Czarnobylu praktycznie nie istniała produkcja sprzętu dozymetrycznego na potrzeby obywateli – pozostawał on wyłącznie w gestii wojska i instytucji naukowych, zwłaszcza w bloku państw komunistycznych. Dopiero po tej katastrofie nastąpił dynamiczny rozwój produkcji dozymetrów dla ludności, przede wszystkim w ZSRR i państwach powstałych po jego rozpadzie. Mierniki te można podzielić na 3 grupy: indykatory promieniowania, dozymetry i radiometry-dozymetry. Indykatory jedynie sygnalizują, czy bieżąca moc dawki promieniowania gamma jest bezpieczna w kontekście długotrwałego narażenia całego ciała oraz czy przekroczenie tego poziomu jest nieznaczne, czy też silne. Dozymetry zaś podają konkretną wartość mocy dawki promieniowania gamma. Dozymetry-radiometry są zaś przyrządami uniwersalnymi: oprócz mocy dawki promieniowania gamma mierzą też aktywność emiterów beta, zarówno na powierzchniach, jak i w produktach żywnościowych. Wspominane przyrządy wykazują bardzo duże różnice, jakości wykonania oraz parametrów użytkowych. Niektóre (głównie indykatory i proste dozymetry) charakteryzują się wręcz absurdalnymi rozwiązaniami technicznymi, inne zaś (szczególnie radiometry-dozymetry) są nadal bardzo użyteczne dla potrzeb amatorskich, oczywiście z zastrzeżeniem traktowania wyników, jako orientacyjnych.
Till Chernobyl disaster there was no production of dosimetry equipment for popular use – those devices were only for scientfic and military purposes, especially in Communist Bloc. After that disaster began extensive development of production of dosimeters for population, mostly in USSR and countries left after dissolution of that Union. Those meters can be divided into three groups: radiation indicators, dosimeters and radiometers-dosimeters. Indicators only show, if current gamma ray dose rate is safe regarding to long-term irradiation of whole body and if exceeding of safe radiation level is slight or significant. Dosimeters give exact value of current gamma ray dose rate. On the other hand, dosimeters-radiometers are universal devices: measure gamma ray dose rate and also activity of beta emitters, both on surfaces and in food products. Mentioned devices exhibit differences of quality and performance characteristics. Some of them (mostly indicators and simple dosimeters) have sometimes ridiculous technical solutions, but other (especially dosimeters-radiometers) still are very usable for amateur usage, of course when treating measurement as only indicative.
Źródło:
Postępy Techniki Jądrowej; 2022, 1; 30--40
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena rentgenowskich aparatów stomatologicznych pod kątem narażenia pacjentów na promieniowanie jonizujące
Evaluation of dental X-ray apparatus in terms of patient exposure to ionizing radiation
Autorzy:
Olszewski, Jerzy
Wrzesień, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2164069.pdf
Data publikacji:
2017-06-27
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
pacjent
promieniowanie rentgenowskie
radiologia stomatologiczna
wejściowa dawka powierzchniowa (ESD)
ankieta
detektory termoluminescencyjne
patient
X-ray
dental radiology
entrance surface dose (ESD)
questionnaire
thermoluminescent dosimeter
Opis:
Wstęp Stosowanie w procedurach stomatologicznych promieniowania rentgenowskiego (rtg.) powoduje narażenie pacjenta na promieniowanie jonizujące. Wielkość tego narażenia zależy przede wszystkim od parametrów stosowanych przy prześwietleniu zęba. Celem badań było określenie wielkości dawek, na jakie narażeni są pacjenci, oraz ocena stanu technicznego aparatów rtg. Materiał i metody Badaniami ankietowymi objęto 1700 gabinetów stomatologicznych. Ankiety odesłało 740 jednostek. Pomiary bezpośrednie wykonano w 100 gabinetach. Pomiary wykonano za pomocą detektorów termoluminescencyjnych i klisz rtg. Wyniki W przeprowadzonych badaniach stwierdzono, że najczęściej stosowany czas ekspozycji wynosi 0,22±0,16 s. Średnia dawka wejściowa dla parametrów najczęściej stosowanych przez stomatologów to 1,7±1,4 mGy. Średnia wydajność lampy rtg. oszacowana na podstawie wykonanych ekspozycji wynosi 46,5±23,7 μGy/mAs. Wnioski Jak wynika z przeprowadzonych badań, znakomita większość aparatów rtg. punktowych spełnia wymagania określone w przepisach. Med. Pr. 2017;68(4):491–496
Background The use of X-ray in dental procedures causes exposure of the patient to ionizing radiation. This exposure depends primarily on the parameters used in tooth examination. The aim of the study was to determine the patients exposure and to assess the technical condition of X-ray tubes. Material and Methods Seventeen hundred dental offices were covered by the questionnaire survey and 740 questionnaires were sent back. Direct measurements were performed in 100 units by using the thermoluminescent detectors and X-ray films. Results The results showed that the most commonly used exposure time is 0.22±0.16 s. The average entrance dose for the parameters used most commonly by dentists is 1.7±1.4 mGy. The average efficiency of X-ray tube estimated on the basis of exposures is 46.5±23.7 μGy/mAs. Conclusions The study results indicate that the vast majority of X-ray tubes meet the requirements specified in the binding regulations. Med Pr 2017;67(4):491–496
Źródło:
Medycyna Pracy; 2017, 68, 4; 491-496
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar indywidualnego równoważnika dawki promieniowania X i gamma za pomocą dozymetru pierścionkowego – wyniki porównań międzylaboratoryjnych
Measurement of personal dose equivalent of X and gamma radiation by ring dosimeter: Results of intercomparison measurements
Autorzy:
Adamowicz, Małgorzata
Papierz, Sylwia
Kacprzyk, Janusz
Kamiński, Zbigniew
Zmyślony, Marek
Powiązania:
https://bibliotekanauki.pl/articles/2166303.pdf
Data publikacji:
2014-11-05
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
porównania międzylaboratoryjne
promieniowanie rentgenowskie i gamma
indywidualny równoważnik dawki
dozymetr pierścionkowy
detektor termoluminescencyjny
interlaboratory comparisons
X-ray and gamma radiation
personal dose equivalent
ring dosimeter
thermoluminescence detectors
Opis:
Wstęp: Celem pracy było potwierdzenie, na podstawie wyników porównań międzylaboratoryjnych dla dozymetrów pierścionkowych, że stosowana metoda badawcza jest odpowiednia do pomiaru indywidualnego równoważnika dawki HP(0,07). Ponadto w pracy przedstawiono procedury kalibracyjne stosowane podczas walidacji metody badawczej przed wdrożeniem do rutynowych pomiarów związanych z oceną narażenia pracowników na działanie promieniowania X i γ. Materiał i metody: Przedmiotem porównań międzylaboratoryjnych były dozymetry pierścionkowe wykonane z elastycznego tworzywa o standardowej średnicy 20 mm i z umieszczonymi wewnątrz dwoma detektorami termoluminescencyjnymi (TL) typu MTS-N - po naeksponowaniu u organizatora porównań odczytywano je za pomocą nowego, manualnego czytnika detektorów TL (prod. FIMEL, Francja). Wszystkie ekspozycje dozymetrów, przeprowadzone dla celów walidacyjnych ww. czytnika, wykonano we wzorcowych wiązkach promieniowania X i γ z zastosowaniem fantomu prętowego ISO. Metodyka wykonanych ekspozycji była odpowiednia do potrzeb pracowni oraz zgodna z metodami stosowanymi przez Europejskę Grupę ds. Dozymetrii Promieniowania (European Radiation Dosimetry Group - EURADOS) - organizatora porównań międzylaboratoryjnych o europejskim zasięgu w zakresie dozymetrii indywidualnej. Wyniki: Wykonane charakterystyki - energetyczna, dawkowa i kątowa dozymetru pierścionkowego - umożliwiły opracowanie wzoru dotyczącego oszacowania indywidualnego równoważnika dawki HP(0,07) oraz poddania go testowi weryfikacyjnemu. Stwierdzono zadowalający wynik testu oceny wielkości HP(0,07) i tym samym potwierdzono gotowość wdrożenia czytnika termoluminescencyjnego do stosowanej metody badawczej oraz uczestniczenia w porównaniach międzylaboratoryjnych. Wnioski: Laboratorium - zgodnie z wymaganiami Polskiego Centrum Akredytacji - uczestniczyło w porównaniach międzylaboratoryjnych (organizowanych przez grupę EURADOS) w zakresie pomiaru dawki równoważnej na ręce promieniowania jonizującego X i γ. Wynik porównania był pozytywny, a jego przedmiotem były dozymetry pierścionkowe. Potwierdzono tym samym prawidłowość realizowanej procedury badawczej. Med. Pr. 2013;64(5):631–637
Background: The aim of the study was to present the results of the interlaboratory comparisons for ring dosimeters and to confirm that the applied method is suitable for measuring the personal dose equivalent HP(0.07). In addition, calibration procedures used in dosimetric measurements in persons occupationally exposed to ionizing photon radiation X and γ were presented. Materials and Methods: Ring dosimeters made of flexible plastics with the diameter of approximately 20 mm, equipped with two thermoluminescence (TL) detectors type MTS-N, were the subject of interlaboratory comparisons. Irradiated detectors were red out using a new manual TLD's reader (FIMEL, France). All TLD exposures were done for validation of TLD readers and were performed using the reference X-ray and γ beams with the ISO rod phantom. The methodology of performed exposures corresponded with the methods applied by the European Radiation Dosimetry Group (EURADOS), the European organizer of interlaboratory comparisons. Results: The energy, dose and angular characteristics of the ring dosimeter allowed to elaborate the formula for estimating and verifying the personal dose equivalent HP(0.07). The test was performed to check and confirm the correctness of the estimated characteristics. The test results were satisfactory, and thus the readiness to implement TLD reader in the used method and to participate in interlaboratory comparisons was confirmed. Conclusions: According to the requirements of the Polish Centre for Accreditation, the laboratory was participating in the interlaboratory comparison organized by EURADOS in terms of the personal dose equivalent HP(0.07). The result of the comparison was satisfactory, therefore the correctness of the testing procedure was confirmed. Med Pr 2013;64(5):631–637
Źródło:
Medycyna Pracy; 2013, 64, 5; 631-637
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of entrance skin dose and effective dose from abdomen radiography in two diagnostic facilities in Aba, Abia State, South-East Nigeria
Autorzy:
Esu, E. O.
Chiegwu, H. U.
Omojola, A. D.
Eze, E. M.
Powiązania:
https://bibliotekanauki.pl/articles/1839405.pdf
Data publikacji:
2021
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Entrance skin dose (ESD)
Local diagnostic reference levels (LDRLs)
Dose area product (DAP)
Effective dose (E)
Absorbed dose (DT)
Thermoluminescent dosimeter (TLD)
Kilovoltage peak (kVp)
milliampere-seconds (mAs)
Opis:
Medical exposure for abdomen radiography is associated with higher doses compared to X-Rays of the chest and other extremities. The study aims to determine the mean entrance skin dose (ESD) for 104 adult patients between 20-89 years with 2 X-Ray units (A and B) in Aba, South-East Nigeria and to determine the ESD at the 75th percentile to estimate the local diagnostic reference levels (LDRLs). This study also determined the effective dose (E), the dose area product (DAP) and the relationship between absorbed dose (DT) and other parameters. This study will also compare its findings with relevant articles where necessary. The study used 2 functional floors mounted X-Ray units. A total of 208 annealed thermoluminescent dosimeters (TLDs) were used made of Lithium Fluoride, doped with Magnesium and Titanium (LiF: Mg, Ti). Two TLD chips were used per patient. The chips were positioned at the anterior and posterior end of the patient respectively for a given beam area for abdomen radiography. After exposure, a calibrated RadPro TLDcube 400 reader (Freiberg Instrument, Germany) was used to estimate individual patient doses. This was done by multiplying the TLD counts by a pre-determined calibration factor (CF). The mean/75th percentile ESD for facilities A and B was 2.92/4.12 and 3.01/3.67 mGy. The E for facilities A and B was 0.73 and 0.82 mSv respectively. There was a good relationship between the DT with ESD, exit dose (ED) and DAP for facility A, but no relationship was seen with other parameters. The mean ESD was lower compared to the National Council on Radiation Protection and Measurements (NCRP 172) and the American Association of Physicists in Medicine (AAPM) reports respectively. The study proved useful and could serve as a reference point to initiate LDRLs within the South-East zone in Nigeria for abdomen radiography.
Źródło:
World Scientific News; 2021, 161; 143-156
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies