Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "density measurement" wg kryterium: Temat


Tytuł:
Low atmospheric density measurement based on Rayleigh scattering of an ultraviolet laser
Autorzy:
Wang, R
Yao, J.
Zhong, K.
Miao, Y.
Cui, H.
Zhao, X.
Zhang, C.
Powiązania:
https://bibliotekanauki.pl/articles/174910.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
atmospheric density measurement
Rayleigh scattering
ultraviolet laser
Opis:
The qualitative measurement of low atmospheric density in the air flow field has been investigated in this paper. The supersonic flow field with Mach number of 1.5 around the NACA0006 aerofoil has been numerically simulated and the transient slight pressure and low density atmosphere have been experimentally determined based on Rayleigh scattering of a 266 nm ultraviolet laser. The scattering patterns have been effectively captured under different atmospheric pressure of 4.5, 92, 470 and 710 Pa with laser energy of only 0.5 mJ. It has been demonstrated that in the pressure range from 4.5 to 1100 Pa, corresponding to the atmospheric density from 4.8105×10–5 kg/m3 to 1.279×10–2 kg/m3, the scattering intensity of an ultraviolet laser is linear to the pressure and density with the slope coefficient of 0.00968 a.u./Pa and 0.83226 a.u./(kg/m3×10–3). It has been proved that Rayleigh scattering is a promising technology for observation of instantaneous and multidimensional distribution of a supersonic flow field.
Źródło:
Optica Applicata; 2013, 43, 3; 597-605
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the dynamic viscosity coefficient of the Stokes viscometer – construction of a measuring set in the Physical Laboratory of the State Higher Vocational School in Tarnów
Autorzy:
Wietecha, Tomasz
Kurzydło, Piotr M.
Powiązania:
https://bibliotekanauki.pl/articles/93186.pdf
Data publikacji:
2019
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
viscosity
Stokes’ law
density measurement
didactic experiment
lepkość
prawo Stokesa
pomiar gęstości
eksperyment dydaktyczny
Opis:
A Stokes viscometer made and launched by the authors in the Physical Laboratory of the State Higher Vocational School in Tarnów was presented. The construction of the viscometer is discussed and the theoretical description of the physical phenomena occurring there is given. The results of measurements on the device, statistical analysis of the measurement uncertainties and confrontation with the literature value are presented - the obtained results correspond very well to the literature values. A possible further development in the accuracy of theoretical description and experimental measurements related to the ellipsoid analysis of the shape of water droplets was suggested. The didactic aspects of the new experiment in the context of the understanding of molecular physics, especially by students of material engineering, were discussed.
Źródło:
Science, Technology and Innovation; 2019, 5, 2; 60-65
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie pomiarów gęstości do oceny podstawowego składu chemicznego modelowych układów mięsno-tłuszczowych
The use of the density measurements to evaluate the basic chemical composition of model meat-fat systems
Autorzy:
Adamczyk, L.
Chmiel, M.
Florowski, T.
Pietrzak, D.
Powiązania:
https://bibliotekanauki.pl/articles/809077.pdf
Data publikacji:
2013
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
mieso
tluszcz
uklady modelowe
sklad chemiczny
gestosc
pomiary gestosci
meat
fat
model composition
chemical composition
density
density measurement
Opis:
Celem niniejszej pracy była ocena możliwości wykorzystania technicznych pomiarów gęstości do szacowania składu chemicznego mięsa. Mieszaniny modelowe uzyskiwano przez wymieszanie rozdrobnionego chudego mięsa wieprzowego (mięsień najdłuższy) z tłuszczem (słonina). Analizowano mieszaniny o różnym stopniu rozdrobnienia – 10, 4 i 2 mm. W poszczególnych układach wymieniano 10% mięsa na składnik tłuszczowy, uzyskując, poza próbkami mięsa i tłuszczu, 9 mieszanin (o stosunku wagowym mięso/ /tłuszcz odpowiednio 90/10, 80/20, 70/30, 60/40, 50/50, 60/40, 70/30, 80/20 i 90/10). Gęstość wyznaczano, dokonując pomiaru masy układu mięsno-tłuszczowego przy znanej jego objętości, którą wyznaczano, umieszczając mieszaniny w 3 różnych rurach pomiarowych o znanej objętości. Wyznaczoną gęstość korelowano z wynikami oznaczeń analitycznych podstawowego składu chemicznego. Wartość uzyskanych współczynników korelacji zależała od stopnia rozdrobnienia układu mięsno-tłuszczowego. W przypadku mniejszych cząstek (2 i 4 mm) uzyskiwano wyższe (w wartości bezwzględnej) współczynniki korelacji (maksymalnie 0,9958 i –0,993) niż przy rozdrobnieniu 10 mm (maksymalnie 0,9814). Badania na układzie modelowym pozwoliły na stwierdzenie, że pomiary techniczne gęstości są metodą o zadowalającej dokładności w szacowaniu składu chemicznego mięsa.
The aim of this study was to evaluate the possibility of using the technical density measurements to estimate the chemical composition of meat. The model mixtures were obtained by mixing minced lean pork meat (m. longissimus) with fat (lard). The mixtures with different degree of mincing – 10, 4 and 2 mm were analyzed. In particular systems 10% of meat was replaced by fat. Beside samples of meat and fat, 9 mixtures (with weight ratio meat/fat 90/10, 80/20, 70/30, 60/40, 50/50, 60/40, 70/30, 80/20 and 90/10 respectively) were prepared. The density was determined by measuring the weight of meat-fat system with its known volume. The mixtures were placed in 3 test tubes with different known volumes. Obtained density was correlated with the results of basic chemical compounds of meat evaluated by analytical methods. The obtained values of correlation coeffi cients depended on the degree of mincing of model meat-fat system. For smaller pieces (2 and 4 mm) correlation coeffi cients (in absolute value) were higher (maximum 0.9958 and –0.993) than 10 mm pieces (maximum 0.9814). Studies on the model system had confi rmed that the technical density measurements had satisfactory accuracy for the estimation of the chemical composition of meat.
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 2013, 573
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Określanie właściwości popiołów lotnych przy użyciu różnych metod i urządzeń badawczych
Determination of fly ashes properties with use of different research methods and measuring devices
Autorzy:
Szponder, D. K.
Trybalski, K.
Powiązania:
https://bibliotekanauki.pl/articles/349933.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
popiół lotny
analiza densymetryczna
pomiar powierzchni właściwej
analiza granulometryczna
rentgenowska analiza dyfrakcyjna
mikroskopia skaningowa
mikroanaliza rentgenowska
analiza termiczna
fly ash
density measurement
specific surface measurements
grain size analysis
X-ray diffraction analysis
scanning microscopy
X-ray microanalysis
thermal analysis
Opis:
Popioły lotne są uciążliwymi odpadami, powstającymi z substancji mineralnych zdyspergowanych w węglu, które w wyniku jego spalenia ulegają wielu procesom fizykochemicznym. Ze względu na zastosowanie różnych metod spalania węgla, różnorodnego składu paliwa, wysoki stopień dyspersji substancji mineralnych paliwa oraz gwałtowność procesów termicznych, ziarna popiołu wykazują wysoki stopień zróżnicowania morfologicznego, składu fazowego i chemicznego. Sprawia to, że poszczególne rodzaje popiołów lotnych znacznie różnią się właściwościami, dlatego też dobór odpowiedniej metody ich utylizacji wymaga dogłębnego poznania ich właściwości fizyko-chemicznych i mineralogicznych. W publikacji zaprezentowano wybrane metody i urządzenia pomiarowe wykorzystywane do określania właściwości fizycznych surowców i odpadów mineralnych, a także ukazano możliwości ich zastosowania do scharakteryzowania właściwości popiołów lotnych.
Fly ash is noxious waste that comes from minerals substances dispersed in coal and are subjected to many physical and chemical processes during coal combustion. Because of different types of coals, different types of combustion, a high level of dispersion of mineral substances in coals and the duration of thermal processes, the particles of fly ash are diversified as to their structure, phase and chemical composition. The diversity of produced fly ash makes it necessary to determinate their physical, chemical and mineralogical properties in order to select suitable utilization method. This paper presents a few research methods and measuring devices used to determine physical, chemical and mineralogical properties of raw and waste materials and also their usefulness to characterize fly ashes properties.
Źródło:
Górnictwo i Geoinżynieria; 2009, 33, 4; 287-298
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
TDR and low-frequency measurements for continuous monitoring of moisture and density in a snow pack
Autorzy:
Stacheder, M.
Powiązania:
https://bibliotekanauki.pl/articles/25546.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
moisture
low-frequency measurement
monitoring
time domain reflectometry
density
snow density
Źródło:
International Agrophysics; 2005, 19, 1
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accessibility of most frequently used physical parameters of soil structure, reliability of measured values, lack of replicates and ways out of this dilemma
Autorzy:
Hartge, K.H.
Powiązania:
https://bibliotekanauki.pl/articles/24699.pdf
Data publikacji:
1997
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
hydraulic conductivity
bulk density
soil depth
soil structure
measurement
physical parameter
Źródło:
International Agrophysics; 1997, 11, 1-2
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Repeatability of measurements of the potential oxygen flux density in the soil by the voltamperometric method
Autorzy:
Bieganowski, A
Powiązania:
https://bibliotekanauki.pl/articles/1401907.pdf
Data publikacji:
2000
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
soil aeration
measurement
oxygen diffusion rate
soil
oxygen flux density
voltammetry
agrophysics
Opis:
Influence of the measuring procedure on the repeatability of measurement of the potential oxygen flux density in the soil has been presented. Five measuring procedures were applied: measurements taken one directly after another, reinstallation of the electrode after each measurement , reinstallation of the electrode after each measurement with a simultaneous mechanical cleaning of surfaces, measurements with 15-min breaks between consecutive measurements, measurements with electrochemical "cleaning" of the electrode surface.The OFD value was determined by a voltamperometric method using a tri-electrode measuring system. It was found out that the best repeatability can be obtained by repeating the measurement with 15-min (or longer) time intervals.
Źródło:
Acta Agrophysica; 2000, 35
1234-4125
Pojawia się w:
Acta Agrophysica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statistical Analysis of Indoor RSSI Read-outs for 433 MHz, 868 MHz, 2.4 GHz and 5 GHz ISM Bands
Autorzy:
Chruszczyk, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/226569.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
indoor location
RSSI measurement
RSSI statistical analysis
ISM band
probability density function
Opis:
This paper presents statistical analysis of RSSI readouts recorded in indoor environment. Many papers concerning indoor location, based on RSSI measurement, assume its normal probability density function (PDF). This is partially excused by relation to PDF of radio-receiver's noise and/or together with influence of AWGN (average white Gaussian noise) radio-channel – generally modelled by normal PDF. Unfortunately, commercial (usually unknown) methods of RSSI calculations, typically as "side-effect" function of receiver's AGC (automatic gain control), results in PDF being far different from Gaussian PDF. This paper presents results of RSSI measurements in selected ISM bands: 433/868 MHz and 2.4/5 GHz. The measurements have been recorded using low-cost integrated RF modules (at 433/868 MHz and 2.4 GHz) and 802.11 WLAN access points (at 2.4/5 GHz). Then estimated PDF of collected data is shown and compared to normal (Gaussian) PDF.
Źródło:
International Journal of Electronics and Telecommunications; 2017, 63, 1; 33-38
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ przyjęcia stałej wartości gęstości paliwa na dokładność przedstawianej w odmierzaczach paliw ciekłych objętości w temperaturze bazowej
The influence of the adoption constant fuel density on the accuracy of measured volume in liquid fuel dispensers at the base temperature
Autorzy:
Kowalczyk, Stanisław
Powiązania:
https://bibliotekanauki.pl/articles/952588.pdf
Data publikacji:
2016
Wydawca:
Główny Urząd Miar
Tematy:
błąd maksymalny
odmierzacz paliw ciekłych
gęstość paliwa
maximum measurement error
fuel dispenser
fuel density
Opis:
Odmierzacze paliw ciekłych mierzą objętość paliwa w temperaturze pomiaru. W artykule przeprowadzono analizę wpływu przyjęcia stałej gęstości paliwa na dokładność przeliczania objętości paliwa wydanego w temperaturze pomiaru, na objętość tego paliwa przedstawianą w temperaturze bazowej (15 °C).
The fuel dispensers measure the volume of liquid fuel in the measuring temperature. The article presents an analysis of the influence of the adoption constant fuel density on the accuracy of counting of the fuel volume dispensed in measurement temperature for the volume of fuel presented at the base temperature (15 °C).
Źródło:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar; 2016, 2 (13); 21-23
2300-8806
Pojawia się w:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using the conservative nature of fresh leaf surface density to measure foliar area
Autorzy:
Castillo, O.S.
Zaragoza, E.M.
Alvarado, C.J.
Barrera, M.G.
Dasgupta-Schubert, N.
Powiązania:
https://bibliotekanauki.pl/articles/24671.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
nature
leaf area
fresh leaf
leaf surface
surface density
measurement
foliar part
leaf mass
planimetry
Opis:
For a herbaceous species, the inverse of the fresh leaf surface density, the Hughes constant, is nearly conserved. We apply the Hughes constant to develop an absolute method of leafarea measurement that requires no regression fits, prior calibrations or oven-drying. The Hughes constant was determined in situ using a known geometry and weights of a sub-set obtained from the fresh leaves whose areas are desired. Subsequently, the leaf-areas (at any desired stratification level), were derived by utilizing the Hughes constant and the masses of the fresh leaves. The proof of concept was established for leaf-discs of the plants Mandevilla splendens and Spathiphyllum wallisii. The conservativeness of the Hughes constant over individual leaf-zones and different leaftypes from the leaves of each species was quantitatively validated. Using the globally averaged Hughes constant for each species, the leaf-area of these and additional co-species plants, were obtained. The leaf-area-measurement-by-mass was cross-checked with standard digital image analysis. There were no statistically significant differences between the leaf-area-measurement-by-mass and the digital image analysis measured leaf-areas and the linear correlation between the two methods was very good. Leaf-areameasurement- by-mass was found to be rapid and simple with accuracies comparable to the digital image analysis method. The greatly reduced cost of leaf-area-measurement-by-mass could be beneficial for small agri-businesses in developing countries.
Źródło:
International Agrophysics; 2014, 28, 4
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes in the reserves of soil retention of arable lands in Central Sudety
Zmiany zasobow retencji glebowej zdrenowanych gruntow ornych w Sudetach Srodkowych
Autorzy:
Peczkowski, G.
Kostrzewa, S.
Orzepowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/81635.pdf
Data publikacji:
2007
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
submontane catchment area
soil retention
drainage
arable land
drainage condition
meteorological condition
moisture density
soil profile
measurement
Opis:
The project presents research involving an analysis and evaluation of water supply of poorly permeable soils in drained arable lands. The analysis dealt with research conducted in 2003–2005 at similar meteorological conditions in an agricultural submountain catchment area situated in Central Sudety. In particular, the analysis concerned water and air properties of examined deposits with regard to their water-retention. The measurements of moisture density of soil profi les and calculated water supplies in layers 1–100 cm showed a crosssection of reserves of soil retention. This depended on the depth and lay of the land as well as drainage conditions. In the lower drainage area at the foot of the slope there was a notably higher level of groundwater than in other places on the slope. In areas where rainfall was the exclusive source of groundwater the measured water-supplies were lower than in multi-sourced drainage areas. The amount of measured supplies for the vegetation period spanning the whole research time was not lower than 70% of the fi eld-water capacity.
Badania przedstawione w pracy obejmujące analizę i ocenę gospodarki wodnej gleb słabo przepuszczalnych zdrenowanych gruntów ornych. Analiza objęła badania przeprowadzone w latach 2003–2005 o zbliżonych warunkach meteorologicznych w rolniczej zlewni podgórskiej, położonej w Sudetach Środkowych. Szczegółowo analizowano właściwości powietrzno-wodne badanych utworów z uwagi na ich retencyjność. Przeprowadzone pomiary uwilgotnienia profilów glebowych i obliczone na tej podstawie zapasy wody w warstwie 0–100 cm wykazały zróżnicowanie rozkładu zasobów retencji glebowej w zależności od położenia w rzeźbie terenu, jak i warunków zasilania. W dziale drenarskim położonym w niższych partiach terenu, u podnóża zbocza notowano wyższe zapasy wody glebowej niż w miejscach położonych na stoku. W działach o zasilaniu wyłącznie opadowym pomierzone zapasy wody były niższe niż w działach o zasilaniu złożonym. Wielkość obliczonych zapasów w okresie wegetacyjnym w całym cyklu badań nie była niższa niż 70% polowej pojemności wodnej.
Źródło:
Annals of Warsaw University of Life Sciences - SGGW. Land Reclamation; 2007, 38; 33-40
0208-5771
Pojawia się w:
Annals of Warsaw University of Life Sciences - SGGW. Land Reclamation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena gęstości gruntu metodą izotopową podczas badania in situ – wyniki wstępne
The assessment of in-situ soil density using nuclear method – preliminary results
Autorzy:
Mykowska, A.
Schwesig, M.
Cieślak, W.
Powiązania:
https://bibliotekanauki.pl/articles/2075702.pdf
Data publikacji:
2017
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
miernik gęstości wilgoci
zagęszczenie gleby
pomiar gleby
sonda izotopowa
moisture density gauge
soil compaction
soil measurement
isotopic probe
Opis:
Soil compaction is one of the key factors during construction investments. There are several methods of measurement and the moisture- -density nuclear gauge is of them. The gauge is popular in the USA but in Poland is practically unused besides the measurements of the post flotation wastes so the authors decided to conduct non-destructive isotopic test to determine the density and soil compaction during construction project. Nuclear method was tested and evaluated in the relation to traditional method (drive cylinder). The results were similar, R2 = 0.99 for wet soil and R2= 0.94 for dry soil but testing by nuclear-gauge is much faster and easier to operate.
Źródło:
Przegląd Geologiczny; 2017, 65, 10/2; 743--747
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simultaneous measurement of oxygen flux and salinity of the water saturated mineral soils
Autorzy:
Bieganowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/24164.pdf
Data publikacji:
2003
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
mineral soil
simultaneous measurement
electrical conductivity
saturated soil
oxygen flux
soil oxygen
soil salinity
water
salinity
flux density
Źródło:
International Agrophysics; 2003, 17, 3
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of two- and three-electrode systems in measurements of potential oxygen flux density in soil
Autorzy:
Bieganowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/25265.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
two-electrode system
soil oxygen flux
soil aeration
measurement
oxygen diffusion rate
soil
three-electrode system
oxygen flux density
potential
Źródło:
International Agrophysics; 2004, 18, 2
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies