Tytuł:
Magnetizing current effect minimization in current transformers
Autorzy:
Dusza, D.
Rzepecki, B.
Powiązania:
https://bibliotekanauki.pl/articles/1813967.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
current transformer
value converter
ratio
error minimization
magnetizing current effect
current transformer's error
current measurement
Opis:
Magnetizing current effect minimization in current transformers is considered in this paper. Double-core current transformer operation is described in the following text. The influence of the magnetizing current, which is a significant element of current transformer's error, has been minimized in a new type of double-core current transformer connection. The accuracy evaluation of built double-core current transformer has been carried out according to obtained transformation precision.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2013, 69, 33; 469--476
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Differential protection with better stabilization for external faults
Zabezpieczenie różnicowe z lepszą stabilizacją dla zwarć zewnętrznych
Autorzy:
Solak, K.
Rebizant, W.
Powiązania:
https://bibliotekanauki.pl/articles/410581.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
current differential criterion
current transformer
fuzzy logic
saturation
Opis:
This paper presents a new differential protection scheme for transmission lines with application of fuzzy signal processing and support of phase comparison criterion. Traditional differential relays may have problems with proper classification of external faults with CT saturation. Better protection stabilization for such cases is obtained with support of fuzzy signal processing. In proposed solution the input signals as well as the standard percentage characteristic are fuzzified. The performance of presented fuzzy protection scheme has been tested with the signals generated with use of EMTP-ATP program and compared to the traditional solution.
W artykule zaprezentowano nowe zabezpieczenie różnicowe, w którym zastosowano rozmyte przetwarzanie sygnałów oraz dodatkowe kryterium porównawczo-fazowe. Proponowane zabezpieczenie jest bardziej odporne na zwarcia zewnętrzne z nasyceniem przekładników prądowych, co potwierdziły przeprowadzone testy. Proponowany algorytm testowany był na sygnałach pochodzących z symulacji w EMTP-ATP, a wyniki porównano ze standardowym przekaźnikiem różnicowym.
Źródło:
Present Problems of Power System Control; 2011, 1; 39-48
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prototype of an Integrating Current Transformer for Beam Intensity Measurements in the Large Hadron Collider
Autorzy:
Krupa, M
Napieralski, A
Powiązania:
https://bibliotekanauki.pl/articles/398102.pdf
Data publikacji:
2013
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
diagnostyka wiązki
pomiar natężenia wiązki
transformator
ICT
FBCT
beam diagnostics
beam intensity measurements
Integrating Current Transformer
Fast Beam Current Transformer
Opis:
The beam intensity (number of particles forming the beam) in the Large Hadron Collider (LHC) is measured by eight current transformers. The average beam current is monitored by the four DC Current Transformers (DCCTs) and the range from a few hundred hertz to over a gigahertz is covered by the four Fast Beam Current Transformers (FBCTs). During the early run of the LHC the beam intensity measured by the FBCTs was observed to be correlated to the beam position and charge distribution. To address the consequential limitations a prototype of an Integrating Current Transformer (ICT) has been developed at CERN as a possible future replacement of the FBCTs. In this article, its design, principle of operation along with results of first beam tests are presented. The measured beam-position-dependency of the ICT has been improved, compared to the FBCT, by a factor of 35 and 50 in the vertical and horizontal planes, respectively.
Źródło:
International Journal of Microelectronics and Computer Science; 2013, 4, 1; 32-36
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of the inductive current transformer derating for operation with distorted currents
Autorzy:
Kaczmarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/201060.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current transformer
distorted current
derating conditions
composite errors
transformer correction factor
accuracy class
Opis:
The aim of the paper is to present a new method for estimation of the CT (Current Transformer) rated primary current and / or load of the secondary winding derating levels for transformation of distorted current in relation to the rated values fixed for transformation of sinusoidal current. This ensures the values of the CT composite errors/transformer correction factors as resulting from its IEC 60044-1/IEEE C57.13 accuracy class in condition of distorted currents transformation.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2014, 62, 2; 363-366
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A complex current ratio device for the calibration of current transformer test sets.
Autorzy:
Çayci, H.
Powiązania:
https://bibliotekanauki.pl/articles/221001.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current transformer test set
ratio error
phase displacement
current comparator
compensation
Opis:
A practical method with high accuracy in generation and application of error values for calibration of current transformer test sets is described. A PC-controlled three-phase power source with a standard wattmeter is used for generating the nominal and error test currents while an electronically compensated current comparator is used to provide summation and subtraction of them, precisely. With this method, any ratio error and phase displacement values could be generated automatically and nominal and test currents could be grounded on the test set safely. Because of its high accurate ratio and phase error generating capability, any type of test set regardless of its operating principles could be calibrated.
Źródło:
Metrology and Measurement Systems; 2011, 18, 1; 159-164
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie nowoczesnych materiałów magnetycznych w konstrukcji magnetowodów
Application of modern magnetic materials to magnetic cores
Autorzy:
Kwiczala, J.
Rodoń, F.
Cholewa, S.
Powiązania:
https://bibliotekanauki.pl/articles/157370.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
materiały amorficzne
rdzeń magnetyczny
przekładnik prądowy
amorphous materials
magnetic core
current transformer
Opis:
W artykule przedstawiono możliwości wykorzystania materiałów amorficznych w konstrukcji magnetowodów. Materiały te charakteryzują się bardzo dużą przenikalnością początkową oraz bardzo małą stratnością. Opisano możliwości zastosowania, np. w konstrukcji przekładników Ferrantiego, rdzeni kompozytowych - rdzeni złożonych z materiału tradycyjnego (żelazokrzem) o małej przenikalności i dużej indukcji nasycenia oraz materiału o dużej przenikalności magnetycznej i małej indukcji nasycenia (metglas).
The paper presents application of amorphous materials to construction of magnetic cores. These materials are characterized by very high initial relative permeability and very low losses. Application of composite cores to construction i.e of. the Ferranti earth-fault current transformer was presented. The composite core consisting of two toroidal cores made of silicon-iron steel (low permeability and high magnetic flux density saturation) and metglas tape (high permeability and low magnetic flux density saturation).
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 7/8, 7/8; 38-41
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ pomiaru symetrycznych i asymetrycznych prądów zwarciowych z zastosowaniem wielozakresowych przekładników prądowych w warunkach laboratorium zwarciowego
The system of measurement of symmetrical and asymmetric short circuit current with multi range current transformers in conditions of short-circuit testing laboratory
Autorzy:
Babiuch, Michał
Olak, Jan
Powiązania:
https://bibliotekanauki.pl/articles/267651.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
badania zwarciowe
pomiar prądów zwarciowych
przekładnik prądowy
short-circuit test
short-circuit current measurement
current transformer
Opis:
W artykule przedstawiono różne wymagania zawarte w normach przedmiotowych, dotyczące parametrów probierczych dla aparatury elektroenergetycznej i różnych rodzajów badań wykonywanych w laboratorium zwarciowym. Opisano wyposażenie badawczo pomiarowe Zwarciowni Instytutu Elektrotechniki w Warszawie (IEL). Przedstawiono układ pomiaru prądów zwarciowych przy użyciu nowo opracowanych przekładników. Opisano metodę sprawdzenia dokładności przekładników prądowych do pomiaru prądów zwarciowych i zamieszczono przykładowe wyniki i oscylogramy z badań. Układ został wdrożony i jest eksploatowany w Zwarciowni IEL.
The article contains an overview of various requirements for the parameters of the Short-Circuit Testing Laboratory: symmetrical and asymmetrical short-circuit currents, time constant for the disappearance of the constant short-circuit component, asymmetrical peak factor and various types of short-circuit tests performed on various devices operating in power systems, contained in different subject standards . The equipment of the Short-Circuit Testing Laboratory of the Electrotechnical Institute and the modernized test chamber No. 6 is described, equipped with new multi range current transformers and a modern measuring system for short-circuit current. The method of checking the accuracy of current transformers for measuring short-circuit currents is described and example oscillograms are given. The values of the adopted parameters of the transformers and the way of designing the test track are highlighted, enabling the simplification of preparatory works to carry out short-circuit tests and research organization. The article contains electrical diagrams of measurement systems, diagrams of current transformer windings and photograph of modernized test chamber No. 6.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 159-162
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Właściwości metody programowej korekcji błędów częstotliwościowych transformatora prądowego w zakresie nieliniowej pracy przy pomiarach mocy
Properties of the method of current transformer frequency error correction within the range of nonlinear operation for power measurements
Autorzy:
Furmankiewicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/157884.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przekładnik prądowy
błędy częstotliwościowe
korekcja błędów częstotliwościowych
current transformer
frequency errors
frequency error correction
Opis:
Artykuł dotyczy metody korekcji częstotliwościowych błędów modułu i błędów fazowych opracowanej dla liniowych obwodów wejściowych. Korekcja realizowana jest w sposób programowy w dziedzinie widmowej. Przedstawiono wyniki badań eksperymentalnych obrazujące skuteczność metody korekcji przy pomiarach mocy sygnałów w zakresie nieliniowej charakterystyki przetwarzania przekładnika prądowego. Wyniki badań wskazują, że możliwa jest korekcja błędów częstotliwościowych obwodów wejściowych przy pomiarach mocy również w zakresie nieliniowej pracy obwodów wejściowych.
The paper deals with the method for correction of dynamic module and phase errors of linear input circuits. The method is implemented in the spectral domain in a programmed manner using the FFT algorithm. Correction of the signal spectrum is based on frequency characteristics of the input circuit module and phase errors determined on the basis of previous measurements [1]. The method can be used for measuring the RMS value and power of signals. This paper presents the results of experiments showing the effectiveness of the correction method for measuring the power in the range of the current transformer nonlinear operation. Figs. 1a and 1b show the frequency characteristics of the module and phase errors of the current transformer used for tests. The block diagrams of the measuring systems used for examination of the correction effectiveness for measuring sinusoidal and non-sinusoidal waveforms are depicted in Figs. 2 and 3. The power measurement errors before and after correction for a sinusoidal waveform of frequency 50 Hz and 350 Hz and a resistive load are presented in Fig. 4a, while Fig. 4b shows the power measurement errors before and after correction for the phase angle between the voltage and current equal to 30 and 60 degrees. In Tab. 1 there are given the power measurement errors before and after correction for the waveform containing the first and third harmonic and a resistive load. In Tab. 2 there are compared the power measurement errors before and after correction for the waveforms similar to that of the thyristor voltage regulator and for a resistive load. The results show that it is possible to correct the frequency errors of current transformers when measuring the power in the range of the transformer nonlinear operation.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 9, 9; 767-769
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Universal Current Transformer for Accurate Measurement of Short-circuit Currents
Uniwersalny przekładnik prądowy do dokładnego pomiaru prądów zwarciowych
Autorzy:
Przybysz, J.
Olak, J.
Piątek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/397436.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
current transformer
aperiodic time constant
short circuit tests
przekładnik prądowy
aperiodyczna stała czasowa
badania zwarciowe
Opis:
The paper presents the design of a special current transformer developed by the Institute of Power Engineering in cooperation with TRANSFORMEX sp. z o.o. The aim of the project was to obtain current transformers allowing not only a thorough transformation of symmetrical currents – which is characteristic for typical current transformers, but also of asymmetrical shortcircuit currents containing an aperiodic component, which are not reproduced by classic current transformers. A current transformer has been developed with a range of short-circuit currents established from 1 kA to 50 kA, and short-circuit currents with an aperiodic component with a decay time constant up to 200 ms, peak value from 2.5 kA to 125 kA, assuming the possibility of five-fold repetition of short circuits with the same value and the same constant component polarity, with the assumed transformation accuracy.
W artykule przedstawiono konstrukcję specjalnego przekładnika prądowego opracowanego we współpracy Instytutu Energetyki z firmą TRANSFORMEX sp. z o.o. Celem pracy było uzyskanie przekładników prądowych umożliwiających nie tylko dokładną transformację prądów przemiennych ustalonych – co jest znamienne dla typowych przekładników prądowych, ale również niesymetrycznych prądów zwarciowych zawierających składową bezokresową, których klasyczne przekładniki prądowe nie odtwarzają. Opracowano przekładnik prądowy o zakresie prądów zwarciowych ustalonych od 1 kA do 50 kA oraz prądów zwarciowych ze składową bezokresową o stałej czasowej zanikania do 200 ms, o wartości szczytowej od 2,5 kA do 125 kA, przy przyjęciu możliwości pięciokrotnego powtarzania zwarć tej samej wartości i tej samej biegunowości składowej stałej, przy założonej dokładności transformacji.
Źródło:
Acta Energetica; 2017, 1; 101-106
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testery liczników energii elektrycznej podłączonych do sieci
Testers of energy meters connected to the power network
Autorzy:
Olencki, A.
Powiązania:
https://bibliotekanauki.pl/articles/153592.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
sprawdzanie liczników energii
testery liczników energii
licznik kontrolny
licznik wzorcowy
current transformer tester
potential transformer tester
power quality analyser
Opis:
Omówiono testery liczników energii elektrycznej podłączonych do sieci energetycznej i kluczowy problem tych testerów - specyfikację dokładności testera w szerokim zakresie dynamicznym napięć, prądów i mocy. Przedstawiono rozwój testerów w ciągu ostatnich kilkunastu lat i ich koncepcje do najnowszego zintegrowanego testera liczników z funkcjami testera przekładników i analizatora jakości energii. Z przedstawionej analizy wynika, że krajowe testery opracowane i produkowane w Zielonej Górze są zgodne z aktualnym stanem techniki na świecie a ich asortyment w pełni pokrywa aktualne potrzeby krajowych użytkowników bez konieczności korzystania z importu.
The paper presents an idea of portable energy meter testers called Portable Working Standard for Testing Electricity Meters which are used for testing single and three phase energy meters, current and potential instrument transformers and installations on site. The key issue of the tester accuracy specifications within the wide dynamic range of voltages, currents and power is discussed in Section 2. The accuracy specification for testers from Zielona Gora is given in Table 1. The table contains the concepts of testers beginning from three phase testers of 0,2 and 0,1 class (Calport 100 shown in Fig.2), economy single phase testers of 0,5 and 0,2 class (Caltest 10 shown in Fig.3), testers with additional function of three phase current and potential instrument transformer testing (Calport 100 Plus presented in Fig.4) to the newest integrated testers designed as three instruments in one compact case - the Energy Meter Tester and the Instrument Transformer Tester and the Power Quality Analyser (PWS 3.3 of MTE Switzerland and Caltest 300 of Calmet Poland presented in Fig.5). The analysis of technique state shows that a good position in the world market in portable energy meter testers is still kept in Poland.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 12, 12; 1557-1560
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu niepoprawnego uziemienia przekładników prądowych w układzie Arona na działanie i wskazania 3-fazowego elektronicznego licznika energii elektrycznej
Analysis of influence of current transformer incorrect ground connections in Aron circuit on power measurement results
Autorzy:
Skórkowski, A.
Skubis, T.
Powiązania:
https://bibliotekanauki.pl/articles/154492.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przekładnik prądowy
układ Arona
3-fazowy licznik energii elektrycznej
współczynnik korekcyjny
current transformer
Aron system
3-phase energy meter
correction factor
Opis:
W pracy przedstawiono wpływ błędnego połączenia obwodów wtórnych przekładników prądowych na działanie i wskazania układu pomiarowo-rozliczeniowego energii elektrycznej. Uziemienie końców uzwojeń stron wtórnych przekładników prądowych zamiast początków skutkuje zmianą rozpływu prądów w torach prądowych licznika. Przeanalizowano sposób określenia współczynnika korek-cyjnego dla błędnie połączonego układu oraz wielkości mających wpływ na jego wartość.
Influence of incorrect connection of current transformer secondary circuits in Aron circuit on the operation of 3-phase electronic meas-uring and billing system of electrical energy in this paper has been described. Grounding the ends of secondary windings of current transformers instead of beginnings ones causes the current flow change in the measuring system, what was never reported before. Such a mistake connection can happen during the energy meter installation, and is difficult to the detection. It results in significant change of measurement results, lowering the cost of energy to be paid. The explanation of the grounding connection influence into measurement results is given in the paper. The correction factor for long time working incorrectly grounded system is calculated.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 10, 10; 829-832
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary pomontażowe urządzeń i sieci elektroenergetycznych średniego napięcia SN
Post-assembly measurements of devices and energy network for MV power grids
Autorzy:
Chrzan, M.
Moszyński, S.
Pietruszczak, D.
Powiązania:
https://bibliotekanauki.pl/articles/310356.pdf
Data publikacji:
2018
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
pomiary pomontażowe
przekładnik prądowy
sieć elektroenergetyczna
sieć średniego napięcia SN
wyłącznik średniego napięcia SN
post-assembly measurements
current transformer
power grid
medium voltage MV power grids
MV voltage switch
Opis:
W artykule przedstawiono analizę pomiarów pomontażowych urządzeń i sieci elektroenergetycznych średniego napięcia SN. Przedstawiono je na przykładach urządzeń przesyłowo-rozdzielczych występujących w różnych zakładach przemysłowo-wytwórczych w Polsce.
The paper presents the analysis of post-assembly measurements of devices and energy network for MV power grids. They are presented on the examples of transmission and distribution devices present in various industrial and manufacturing plants in Poland.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2018, 19, 12; 341-349
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using G.652 telecommunication single-mode optical fiber for a measurement coil of the interferometric current sensor
Zastosowanie jednomodowego światłowodu telekomunikacyjnego g.652 do realizacji cewki pomiarowej w interferometrycznym czujniku natężenia prądu
Autorzy:
Torbus, S. A.
Powiązania:
https://bibliotekanauki.pl/articles/194116.pdf
Data publikacji:
2010
Wydawca:
Politechnika Bydgoska im. Jana i Jędrzeja Śniadeckich. Wydawnictwo PB
Tematy:
stała Verdeta
zjawisko magnetooptyczne Faradaya
interferometryczny czujnik natężenia prądu
światłowodowy przekładnik prądowy
światłowód jednomodowy
światłowód wielomodowy
Verdet constant
mangeto-optical phenomenon
interferometric current sensor
optical fiber current transformer
single-mode optical fiber
multi-mode optical fiber
Opis:
This article describes benefits of using a G.652 telecommunication optical fibre instead of a multi-mode optical fibre for a measurement coil of the interferometric current sensor. The simulation results were presented for coils with various numbers of turns and made of various optical fibres - a single-mode and multi-mode fibre.
W artykule pokazano, że preferowane jest stosowanie standardowego światłowodu telekomunikacyjnego G.652 do wykonania cewki pomiarowej interferometrycznego czujnika natężenia prądu, zamiast światłowodu wielomodowego. Przedstawiono wyniki symulacji dla cewek o różnej liczbie zwojów i różnych wartości natężenia prądu dla dwóch różnych typów włókien światłowodowych - jednomodowego i wielomodowego.
Źródło:
Zeszyty Naukowe. Elektrotechnika / Uniwersytet Technologiczno-Przyrodniczy w Bydgoszczy; 2010, 15; 67-74
0209-0570
Pojawia się w:
Zeszyty Naukowe. Elektrotechnika / Uniwersytet Technologiczno-Przyrodniczy w Bydgoszczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratorium wysokich napięć Politechniki Wrocławskiej 1910-2020
High voltage laboratory of the Wroclaw University of Science and Technology
Autorzy:
Chrzan, Krystian Leonard
Powiązania:
https://bibliotekanauki.pl/articles/268939.pdf
Data publikacji:
2020
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
generator udarowy
dzielnik napięciowy
transformator prądowy
laboratorium wysokich napięć
wyposażenie
Politechnika Wrocławska
historia
impulse generator
voltage divider
current transformer
high-voltage laboratory
equipment
Wrocław University of Science and Technology
history
Opis:
Opisano wyposażenie i lokalizacje laboratorium wysokich napięć na Politechnice Wrocławskiej od 1910 roku. Pierwsze laboratorium oddano do eksploatacji bezpośrednio po otwarciu Technische Hochschule Breslau. Jednak dopiero po przybyciu Prof. Paula Boeninga w 1936 r. zaczęto je w pełni wykorzystywać. Prof. Jerzy Ignacy Skowroński w 1946 r. przeniósł laboratorium do znacznie większego pomieszczenia w gmachu A-1, a następnie do budynku D-1 po jego ukończeniu w 1954 roku. Działalność laboratorium można podzielić na trzy okresy: przed II wojną światową 1910-1945, lata kierownictwa Prof. J. I. Skowrońskiego i okres 1971–2020. Największy rozwój laboratorium w zakresie zakupów wyposażenia i liczby zatrudnionych (20 pracowników) przypada na lata 1960-1990. W referacie opisano najważniejsze wyposażenie zakupione lub zmontowane przez Jerzego Lisieckiego.
Equipment and locations of the high voltage laboratory have been described since 1910. The first laboratory was put into operation immediately after the opening of the Technische Hochschule Breslau. However, only after the arrival of prof. Paul Boening in 1936 began to be fully used. Professor Jerzy Ignacy Skowroński in 1946 moved the laboratory to a much larger room in the A-1 building and then to the D-1 building after its completion in 1954. The laboratory can be divided into three periods: the time before World War II 1910-1945, the years of management of Prof. J.I. Skowronski and the years 1971–2020. The years 1960-1990 were the period of the greatest development, purchase of equipment and employment of almost 20 employees. The article describes the most important equipment purchased or assembled by Jerzy Lisiecki.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2020, 70; 41-46
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Korekcja kształtu prądu wtórnego przekładnika prądowego
Correction of the Secondary Current Shape of Current Transformer
Autorzy:
Biel, B.
Jakubowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/1368621.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
przekładnik prądowy
uzwojenie wtórne
krzywa magnesowania
pętla histerezy
energia strat w rdzeniu
przebieg odkształcony
błąd prądowy
błąd całkowity
błąd kształtu
current transformer
secondary winding
magnetization curve
hysteresis loop
energy loss in the core
process deformed
current error
total error
shape error
Opis:
The currents measured in industrial applications reach very high values and at the same time their courses are more and more distorted. In the case of the measurement of alternating current of very high intensity it is necessary to use a current transformer. Such a current transformer should only change the scale of the course but retain its shape. Unfortunately, current transformers distort the shape of the course. These distortions depend mainly on the harmonic content in the primary current and the distortions caused by the ferromagnetic core. The purpose of the article is to define the methodology to minimize the distortion of the secondary current caused by the current transformer, while leaving the distortion of the original course. Minimizing distortions does not consist in the idealization of core parameters but on the development of the algorithm for processing samples using the CT ratio parameters. In this method CT ratio parameters are determined on the basis of the data specified on the nameplate as well as on the basis of measurements. These measurements are carried out without intervention in its interior. The method presented enables more accurate reproduction of the shape of current being measured and can be applied in the industry. The method can be used both for transformers at the design stage and those already in operation.
Prądy mierzone w zastosowaniach przemysłowych osiągają bardzo duże wartości, a jednocześnie kształty przebiegów są coraz bardziej odkształcone. W przypadku pomiaru prądu zmiennego o dużym natężeniu musi być stosowany przekładnik prądowy. Stosowany przekładnik powinien tylko zmienić skalę przebiegu, zachowując jego kształt. Niestety przekładniki prądowe zniekształcają jego kształt. Zniekształcenia te zależą głównie od zawartości harmonicznych w prądzie pierwotnym oraz zniekształceń wprowadzanych przez rdzeń ferromagnetyczny. Celem artykułu jest określenie metodyki zminimalizowania zniekształceń przebiegu prądu wtórnego wprowadzanych przez przekładnik, przy pozostawieniu zniekształceń przebiegu pierwotnego. Minimalizacja zniekształceń nie polega na idealizacji parametrów rdzenia, ale na opracowaniu algorytmu przetwarzania próbek, przy wykorzystaniu parametrów przekładnika. W metodzie tej parametry przekładnika określa się na podstawie danych z tabliczki znamionowej oraz pomiarów. Pomiary te wykonywane są bez ingerencji w jego wnętrze. Przedstawiona metoda umożliwia dokładniejsze odwzorowanie kształtu przebiegu prądu mierzonego i będzie mogła być stosowana w przemyśle. Może być ona stosowana do przekładników zarówno projektowanych jak i już będących w eksploatacji.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 1, 98; 7-12
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie światłowodów telekomunikacyjnych G.652, G.653 i G.655 w polarymetrycznych czujnikach natężenia prądu
Using G.652, G.653 and G.655 telecommunication optical fibers for a polarimetric current sensor
Autorzy:
Torbus, S. A.
Powiązania:
https://bibliotekanauki.pl/articles/154280.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stała Verdeta
zjawisko magnetooptyczne Faradaya
polarymetryczny czujnik natężenia prądu
światłowodowy przekładnik prądowy
światłowód jednomodowy
światłowód wielomodowy
linia wysokiego napięcia
Verdet constant
mangeto-optical phenomenon
polarimetric current sensor
optical fiber current transformer
single-mode optical fiber
multi-mode optical fiber
high-voltage line
Opis:
W artykule pokazano, że preferowane jest stosowanie światłowodów telekomunikacyjnych standardów G.652, G.653 i G.655 do wykonania cewki pomiarowej polarymetrycznego czujnika natężenia prądu, zamiast światłowodu wielomodowego. Przedstawiono wyniki symulacji dla cewek o różnej liczbie zwojów i różnych wartości natężenia prądu dla światłowodów jednomodowych i wielomodowych. Zaprezentowano również analizę dokładności pomiaru natężenia prądu za pomocą czujnika polarymetrycznego, w którym cewka pomiarowa wykonana jest ze światłowodu telekomunikacyjnego. W oparciu o symulację komputerową określono, że ułożenie przewodów linii wysokiego napięcia 110 kV nie wpływa na dokładność pomiaru rozpatrywanym czujnikiem natężenia prądu.
This paper describes benefits of using G.652, G.653 and G.655 telecommunication optical fibres for a measurement coil of the polarimetric current sensor. There are given the simulation results for coils of different number of turns and made of various optical fibres - a single-mode and multi-mode fibre. There is presented analysis of the accuracy of current measurement by means of the polarimetric sensor, in which the measurement coil is made of telecommunication optical fibers. Using the classical theory of measurement errors, it is shown that polarimetric current sensors with the measurement coil made of telecommunication optical fiber are characterised by a very high accuracy. Based on computer simulations, it was proved that the 110 kV high voltage cable laying does not affect the presented current sensor accuracy. In the presented polarimetric sensor model it was shown that the distance from the center of the high-voltage power line cable to the optical fiber should be at least 55 mm in order to prevent the impact of macrobendings. This feature will make it possible to use this sensor in remote measurement systems.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 5, 5; 441-446
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza prądu załączania transformatora
Analysis of transformer inrush current
Autorzy:
Horiszny, J.
Powiązania:
https://bibliotekanauki.pl/articles/153852.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator
prąd włączania
charakterystyka magnesowania
transformer
inrush current
flux-current characteristic
Opis:
Włączenie zasilania nieobciążonego transformatora może spowodować pobór prądu osiągającego znaczną wartość szczytową, przekraczającą wielokrotnie wartość znamionową. W artykule przedstawiono opis analityczny tego zjawiska. Analizę przeprowadzono w oparciu o zlinearyzowaną charakterystykę magnesowania rdzenia transformatora. Pozwoliło to na uzyskanie niezbyt skomplikowanych zależności opisujących przebiegi prądu włączania i strumienia magnetycznego. Na tej podstawie określono wpływ takich czynników, jak moment włączenia napięcia, charakter obwodu pierwotnego i stopień namagnesowania rdzenia na przebieg i wartość maksymalną prądu.
Energization of a transformer with no load is always accompanied by an inrush current. Peak of the current may be several times higher then its rated value. An analytical approach to the phenomenon is presented in the article. The analysis was carried out basing on piecewise linear flux-current characteristic. This resulted in obtaining simple formulas to describe variations of inrush current and magnetic flux. Basing on these the influence of several factors (including: time of switching on of the voltage, circuit inductance, residual flux of the core) upon variation and maximal value of current was determined.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 4, 4; 139-141
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Numerical Model of 2G YBCO Superconducting Tape in the Windings of the Transformer
Autorzy:
Woźniak, Ł.
Surdacki, P.
Jaroszyński, L.
Powiązania:
https://bibliotekanauki.pl/articles/117874.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
YBCO 2G tape
superconducting transformer
current limitation
Opis:
Computer assisted calculations consists in applying software for the simu-lation of models of certain devices and later analysing their behavior under given conditions corresponding to real working conditions in a specific environment.The paper proposes a circuit model of 2G YBCO super-conducting tape created in the PSpice program. The model consists of passive blocks and active user blocks of analogue behavioural modelling (ABM). ABM blocks calculate the conductances, the currents of the indi-vidual layers of the superconducting tape, its thermal capacity, the heating power, the cooling power and resulting temperature of the tape. The model uses table of thermal power density passed to the liquid nitrogen vs. temperature. Smooth transition of the YBCO superconductor layer into the resistive state is described by Rhyner’s power law. The developed model was used for generating waveforms of thermal and electrical quantities.
Źródło:
Applied Computer Science; 2017, 13, 2; 23-38
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Long lasting transients in power filter circuits
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/97714.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
inrush current
arc fumace transformer
harmonic filter
switching transient
Opis:
The practice of operating AC electrical arc fumace power supply systems has shown that energizing unloaded fumace transformer can cause long lasting transients in filter circuits of static VAR compensators used in the supply systems. Examination of the supply system configuration impact on switching transient behaviour has been carried out by example of a 50 MVA arc fumace unit. The transient analysis has been carried out through simulating by Matlab/Simulink software.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 324-333
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computation of electromagnetic forces in the windings of amorphous core transformers
Autorzy:
Thanh, Bao Doan
Tung, Doan Duc
Le, Tuan-Ho
Powiązania:
https://bibliotekanauki.pl/articles/24202732.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
amorphous transformer
electromagnetic force
leakage flux
magnetic vector potential formulation
short-circuit current
Opis:
Electromagnetic forces generated by the short circuit current and leakage flux in low- and high-voltage windings of distribution transformers as well as amorphous core transformers will cause the translation, destruction, and explosion of the windings. Thus, the investigation of these forces plays a significant role for researchers and manufacturers. Many authors have recently used the finite element method to analyze electromagnetic forces. In this paper, an analytic model is first developed for magnetic vector potential formulations to compute the electromagnetic forces (i.e., axial and radial forces) acting on the low- and high-voltage windings of an amorphous core transformer. The finite element technique is then presented to validate the results obtained from the analytical model. The developed model is applied to an actual problem.
Źródło:
Archives of Electrical Engineering; 2023, 72, 2; 521--539
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Study on the Low Frequency Transients in Power Transformers and Some Protection-Related Issues
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/1203944.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
transformer cores
inrush current
protection
transients
modeling
equivalent circuit
low frequency
nonlinear model
simulation
Opis:
This paper presents typical results for the non-linear low frequency transients following the energization of power transformers. The three operating conditions of no-load, full-load and internal faults are considered. A direct analytical procedure is applied for solving the corresponding set of differential equations describing the transformers equivalent circuit. The core representation is based on the use of curve fitting applied to their magnetization curves. The results include plots versus time for the supply current, the core flux, the magnetizing current as well as the internal induced voltage. Moreover, graphs for the hysteresis loops relating the instantaneous values of both the excitation current and the core flux are given. An approach is also presented for the numerical determination of the amplitudes of the different harmonics existing in any of these signals utilizing the corresponding equidistant samples. As examples, the DC offset as well as harmonics up to the fourth order are considered. It is shown that several useful features can be extracted from the results in both the time and harmonic domains that can assist in differentiating between overcurrents resulting from short-circuits or inrush phenomena.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2014, 17, 2; 9-16
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite element analysis of eddy current losses in pulse transformer
Analiza strat wiroprądowych w transformatorze impulsowym metodą elementów skończonych
Autorzy:
Łyskawiński, W.
Powiązania:
https://bibliotekanauki.pl/articles/159946.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
transformator impulsowy
straty wiroprądowe mocy
metoda elementów skończonych
pulse transformer
eddy current losses
FEM analysis
Opis:
In the paper an algorithm for power loss determination in pulse transformers using a field-circuit model is described. The software based on the algorithm is used to calculate eddy current losses and determine efficiency of a pulse transformer. Eddy current power losses and efficiency of a pulse transformer for different load resistances, input signal shapes and lengths of the central leg of the core are analysed. Selected results of simulations are shown.
Wiroprądowe straty mocy ΔP w transformatorze impulsowym można wyznaczyć na podstawie czasowego przebiegu oraz przestrzennego rozkładu wektora gęstości prądu z zależności (1). Obliczanie tych strat jest jednak zagadnieniem trudnym, ponieważ w ogólnym przypadku przy wymuszeniu napięciowym w układach zawierających elementy nieliniowe nie jest znany a priori przebieg i rozkład gęstość prądu w uzwojeniach i prądów wirowych w rdzeniu. W celu wyznaczenia tych prądów posłużono się modelem polowo-obwodowym transformatora impulsowego. Model ten obejmuje równania pola elektromagnetycznego (3) i równania opisujące rozpływ prądów w obwodach elektrycznych (2). Ze względu na nieliniowość, szybką zmienność pola w czasie oraz złożoną strukturę równań tych nie można rozwiązać analitycznie. W tym celu wykorzystuje metodę elementów skończonych, polegającą na dyskretyzacji przestrzeni i czasu. W wyniku uzyskuje się układ nieliniowych równań algebraicznych (4). Do rozwiązania tego układu równań wykorzystuje się iteracyjną metodę Newtona-Raphsona. Na podstawie obliczonych rozkładów gęstości prądów z zależności (1) wyznacza się wiroprądowe straty mocy w rdzeniu i straty mocy w uzwojeniach. Na podstawie przedstawionego algorytmu opracowano program do wyznaczania wiroprądowych strat mocy i sprawności w transformatorze impulsowym. Rozpatrzono transformator o mocy 240 W z rdzeniem ETD 44 wykonanym z ferrytu N 67 o strukturze przedstawionej na rys. 1. W rozważaniach uwzględniono nieliniowe właściwości materiałów magnetycznych oraz prądy wirowe indukujące się w rdzeniu i uzwojeniach. Transformator obciążono rezystancją Ro. Dla Ro = Rn uzyskano znamionowy prąd obciążenia. Ze względu na szeroki zakres zmian względnej rezystancji obciążenia r = Ro/Rn na zamieszczonych w artykule wykresach posłużono się skalą logarytmiczną. Badano wpływ zmian względnej rezystancji obciążenia r i kształtu sygnału zasilającego na względne straty mocy w uzwojeniach pu = ΔPu /ΔPun (rys. 2) i w rdzeniu pr = ΔPr /ΔPrn (rys. 3) oraz sprawność η transformatora (rys. 6). Przy obliczaniu sprawności uwzględniono straty histerezowe wyznaczone w sposób przybliżony na podstawie danych katalogowych. Sprawność tą porównano w pewnym zakresie obciążeń ze sprawności transformatora pracującego w zasilaczu impulsowym (rys. 4). Opracowane oprogramowanie umożliwia analizę wiroprądowych strat mocy w uzwojeniach i rdzeniu transformatorów impulsowych. Zatem może być przydatne w projektowaniu i optymalizacji rozpatrywanych transformatorów.
Źródło:
Prace Instytutu Elektrotechniki; 2006, 229; 75-85
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A dual inductor-fed boost converter with an auxiliary transformer and voltage doubler
Autorzy:
Dawidziuk, J.
Powiązania:
https://bibliotekanauki.pl/articles/201526.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DC/DC boost converter
current-fed
dual inductor-fed
auxiliary transformer
voltage doubler
photovoltaic systems
Opis:
This paper presents a dual inductor-fed boost converter with an auxiliary transformer and voltage doubler for sustainable energy power converters. The new topology integrates a two-phase boost converter and a dual inductor-fed boost converter. The energy stored and transferred by both inductors can attain a wide input-voltage and load range which uses a constant switching frequency, by controlling the time duration of the simultaneous conduction of the two switches. Among other current-fed type boost converters the presented topology is attractive due to the high voltage conversion ratio, less stress on the components and less switch conduction loss. To verify the feasibility of this topology, the principles of operation, theoretical analysis, and experimental waveforms are presented for a 1 kW prototype.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 787-791
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The new concept of the 2G HTS superconducting transformer
Nowa koncepcja transformatorów nadprzewodnikowych z taśm HTS 2G
Autorzy:
Wojtasiewicz, G.
Powiązania:
https://bibliotekanauki.pl/articles/159138.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
superconducting transformer
2G HTS tape
transformer windings
parallel tapes
current distribution
power losser
transformator nadprzewodnikowy
taśma HTS 2G
uzwojenia transformatorów
taśmy równoległe
Opis:
The new 2G HTS tapes with high critical current and high resistivity in the normal state allow to build low-cost transformers with high short-circuit strength for the low and medium power distribution substations. The authors consider that currently the best chance of building have transformers, which rated currents of their windings do not exceed or slightly exceed the critical current of used superconducting tapes. Such units could be the low or medium voltage transformers with power less than 10 MVA, where the high voltage winding can be made with single HTS tape while the low voltage winding can also be made of single HTS tape or two – three tapes connected in parallel. This eliminates the need of tape transposition or application of the Roebel’s cable. Superconducting transformers could stabilize the low or medium power network and increase the connectivity of renewable and dispersed energy sources. The article presents an analysis of the possibility of using the low and medium voltage superconducting transformers. Such units could be e.g transformers working with renewable energy sources.
Nowe taśmy nadprzewodnikowe 2G HTS o wysokim prądzie krytycznym i wysokiej rezystywności w stanie rezystywnym pozwalają na budowę transformatorów o wysokiej odporności na zwarcia dla sieci dystrybucyjnych niskich i średnich energii. Obecnie największe szanse na budowę mają transformatory, których znamionowe prądy uzwojeń nie przekraczają lub nieco przekraczają wartości prądu krytycznego zastosowanych taśm nadprzewodnikowych. Takimi jednostkami mogą być transformatory niskiego lub średniego napięcia o mocy poniżej 10 MVA, gdzie uzwojenie wysokonapięciowe może być wykonane pojedynczą taśmą HTS, a uzwojenie niskonapięciowe może być również wykonane z pojedynczej taśmy HTS lub dwóch - trzech taśm połączonych równolegle. Eliminuje to konieczność transpozycji taśm a tym samym zastosowania kabla Roebel. Zastosowanie transformatorów nadprzewodnikowych mogłoby ustabilizować sieć energetyczną niskiego i średniego napięcia i zwiększyć zdolność łączeniową odnawialnych i rozproszonych źródeł energii.
Źródło:
Prace Instytutu Elektrotechniki; 2017, 277; 43-54
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of higher harmonics generation by non-linear loads
Analiza wytwarzania wyzszych harmonicznych przez odbiorniki nieliniowe
Autorzy:
Necka, K.
Powiązania:
https://bibliotekanauki.pl/articles/793595.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
nonlinear load
distortion factor
higher harmonics
oscillogram
low-voltage grid
transformer station
supply voltage
supply current
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zwarcie awaryjne transformatora
Emergency short-circuit of the transformer
Autorzy:
Bernatt, Jakub
Gawron, Stanisław
Glinka, Tadeusz
Polak, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2135014.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
transformator
zwarcie symetryczne
zwarcie awaryjne
prąd udarowy
transformer
symmetrical short-circuit
emergency short-circuit
surge current
Opis:
Jedną z prób przewidzianą w programie badań pełnych transformatorów nowych jest próba zwarcia. Sposób przeprowadzenia tej próby jest opisany w normie PN-EN 60076-5. W eksploatacji transformatorów, które pracują w sieci elektroenergetycznej, zdarzają się także zwarcia przypadkowe. Przykładem jest transformator 16 MVA, 110/20kV z wyjściem kablowym. Kabel został uszkodzony. Powstało zwarcie dwufazowe. Transformator uległ awarii. Bazując na tym przykładzie i wykorzystując schematy zastępcze, obliczono prąd udarowy przy zwarciu symetrycznym i prąd udarowy przy zwarciu dwufazowym. Oceniono przepięcia indukowane przy wyłączaniu prądu zwarcia. Wskazano przyczynę awarii transformatora.
One of the tests included in the test program for complete new transformers is the short-circuit test. The method of carrying out this test is described in the PN-EN 60076-5 standard. In the operation of transformers that operate in the power grid, accidental short-circuits also occur. An example is a 16 MVA, 110 / 20kV transformer with cable outlet. The cable has been damaged. A two-phase short circuit has arisen. The transformer has failed. Based on this example and using equivalent diagrams, the impulse current for symmetrical shortcircuit and the impulse current for two-phase short-circuit were calculated. The induced overvoltage when switching off the short-circuit current was assessed. The cause of the transformer failure is indicated.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 11--19
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka on-line izolatorów przepustowych typu OPI w transformatorach WN
On-line diagnostics of OPI bushings in HV transformers
Autorzy:
Bernatt, Jakub
Gawron, Stanisław
Glinka, Tadeusz
Polak, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2146333.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
transformator
izolator przepustowy
tgδ
współczynnik strat dielektrycznych
prąd upływu
transformer
bushing
dielectric loss factor
leakage current
Opis:
Parametrem diagnostycznym izolatorów przepustowych stosowanym standardowo on-line jest pomiar tg między punktem pomiarowym P i kołnierzem K. Wykazano, że tg nie informuje w sposób dostateczny o stanie technicznym izolatora przepustowego. Polecanym parametrem diagnostycznym on-line izolatora jest prąd upływu mierzony w obwodzie rezystancji włączonej między punkty P-K. Korzystne jest sumowanie sygnałów prądowych z izolatorów trzech faz. Sumowanie należy realizować na transformatorku (rys. 9). Pomiar prądu sumarycznego 0 jest prosty w realizacji i wolny od zakłóceń.
The standard diagnostic parameter HV bushings used on-line is the measurement of tgδ between the measuring point P and the flange K. It has been shown that tgδ does not sufficiently inform about the technical condition of the bushing. The recommended on-line diagnostic parameter of the insulator is the leakage current I measured in the circuit of resistance connected between points P-K. It is advantageous to sum the current signals from the insulators of the three phases. Adding up should be done on a transformer (Fig. 9). Measurement of the summary current 0 is simple to implement and free from interferences.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 35--40
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie nowego algorytmu kompensacji prądowej w regulatorze przełącznika zaczepów transformatora WN/SN
Application of a new algorithm for current compensation at the regulator of the tap-changer for HV/MV transformers
Autorzy:
Korpikiewicz, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/268260.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
kompensacja prądowa
asymetria napięć
asymetria obciążenia
STM32
elektroniczne przełączniki zaczepów transformatora
current compensation
voltage asymmetry
load asymmetry
solid-state tap-changers for transformer
Opis:
Artykuł dotyczy regulacji napięcia w sieci SN za pomocą statycznych przełączników zaczepów. W artykule rozważano problematykę kompensacji prądowej w regulatorze przełączników zaczepów transformatora WN/SN. Kompensacja prądowa obecnie jest często wyłączana. Jest to spowodowane tym, że kompensacja dotyczy wirtualnej pojedynczej linii SN. W artykule przedstawiono wyniki symulacji na modelu fizycznym dla prostej sieci SN zasilanej ze stacji WN/SN przy występowaniu asymetrii napięć i obciążeń dla trzech przypadków: wyłączona kompensacja prądowa, klasyczna kompensacja oraz proponowana jej nowa formuła. Proponowany algorytm zaimplementowano na mikrokontrolerze STM32. W celu uwzględnienia asymetrii wykorzystano pomiary w trzech fazach, co wymaga modyfikację układu pomiarowego.
The article concerns voltage regulation in MV network by means of static tap changers. The article considers the problem of current compensation in the HV / MV transformer tap changer controller. Current compensation is often turned off. This is due to the fact that the compensation applies to a virtual single SN line. The article presents simulation results on a physical model for a simple MV network fed from a WN / SN station with the occurrence of voltage and load asymmetry for three cases: switched off current compensation, classical compensation and the proposed new formula. The proposed algorithm has been implemented on the STM32 microcontroller. In order to take into account the asymmetry, measurements in three phases were used, which requires modification of the measurement system.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 105-108
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-28 z 28

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies