Tytuł:
Magnetizing current effect minimization in current transformers
Autorzy:
Dusza, D.
Rzepecki, B.
Powiązania:
https://bibliotekanauki.pl/articles/1813967.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
current transformer
value converter
ratio
error minimization
magnetizing current effect
current transformer's error
current measurement
Opis:
Magnetizing current effect minimization in current transformers is considered in this paper. Double-core current transformer operation is described in the following text. The influence of the magnetizing current, which is a significant element of current transformer's error, has been minimized in a new type of double-core current transformer connection. The accuracy evaluation of built double-core current transformer has been carried out according to obtained transformation precision.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2013, 69, 33; 469--476
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Differential protection with better stabilization for external faults
Zabezpieczenie różnicowe z lepszą stabilizacją dla zwarć zewnętrznych
Autorzy:
Solak, K.
Rebizant, W.
Powiązania:
https://bibliotekanauki.pl/articles/410581.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
current differential criterion
current transformer
fuzzy logic
saturation
Opis:
This paper presents a new differential protection scheme for transmission lines with application of fuzzy signal processing and support of phase comparison criterion. Traditional differential relays may have problems with proper classification of external faults with CT saturation. Better protection stabilization for such cases is obtained with support of fuzzy signal processing. In proposed solution the input signals as well as the standard percentage characteristic are fuzzified. The performance of presented fuzzy protection scheme has been tested with the signals generated with use of EMTP-ATP program and compared to the traditional solution.
W artykule zaprezentowano nowe zabezpieczenie różnicowe, w którym zastosowano rozmyte przetwarzanie sygnałów oraz dodatkowe kryterium porównawczo-fazowe. Proponowane zabezpieczenie jest bardziej odporne na zwarcia zewnętrzne z nasyceniem przekładników prądowych, co potwierdziły przeprowadzone testy. Proponowany algorytm testowany był na sygnałach pochodzących z symulacji w EMTP-ATP, a wyniki porównano ze standardowym przekaźnikiem różnicowym.
Źródło:
Present Problems of Power System Control; 2011, 1; 39-48
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prototype of an Integrating Current Transformer for Beam Intensity Measurements in the Large Hadron Collider
Autorzy:
Krupa, M
Napieralski, A
Powiązania:
https://bibliotekanauki.pl/articles/398102.pdf
Data publikacji:
2013
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
diagnostyka wiązki
pomiar natężenia wiązki
transformator
ICT
FBCT
beam diagnostics
beam intensity measurements
Integrating Current Transformer
Fast Beam Current Transformer
Opis:
The beam intensity (number of particles forming the beam) in the Large Hadron Collider (LHC) is measured by eight current transformers. The average beam current is monitored by the four DC Current Transformers (DCCTs) and the range from a few hundred hertz to over a gigahertz is covered by the four Fast Beam Current Transformers (FBCTs). During the early run of the LHC the beam intensity measured by the FBCTs was observed to be correlated to the beam position and charge distribution. To address the consequential limitations a prototype of an Integrating Current Transformer (ICT) has been developed at CERN as a possible future replacement of the FBCTs. In this article, its design, principle of operation along with results of first beam tests are presented. The measured beam-position-dependency of the ICT has been improved, compared to the FBCT, by a factor of 35 and 50 in the vertical and horizontal planes, respectively.
Źródło:
International Journal of Microelectronics and Computer Science; 2013, 4, 1; 32-36
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of the inductive current transformer derating for operation with distorted currents
Autorzy:
Kaczmarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/201060.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current transformer
distorted current
derating conditions
composite errors
transformer correction factor
accuracy class
Opis:
The aim of the paper is to present a new method for estimation of the CT (Current Transformer) rated primary current and / or load of the secondary winding derating levels for transformation of distorted current in relation to the rated values fixed for transformation of sinusoidal current. This ensures the values of the CT composite errors/transformer correction factors as resulting from its IEC 60044-1/IEEE C57.13 accuracy class in condition of distorted currents transformation.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2014, 62, 2; 363-366
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A complex current ratio device for the calibration of current transformer test sets.
Autorzy:
Çayci, H.
Powiązania:
https://bibliotekanauki.pl/articles/221001.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current transformer test set
ratio error
phase displacement
current comparator
compensation
Opis:
A practical method with high accuracy in generation and application of error values for calibration of current transformer test sets is described. A PC-controlled three-phase power source with a standard wattmeter is used for generating the nominal and error test currents while an electronically compensated current comparator is used to provide summation and subtraction of them, precisely. With this method, any ratio error and phase displacement values could be generated automatically and nominal and test currents could be grounded on the test set safely. Because of its high accurate ratio and phase error generating capability, any type of test set regardless of its operating principles could be calibrated.
Źródło:
Metrology and Measurement Systems; 2011, 18, 1; 159-164
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie nowoczesnych materiałów magnetycznych w konstrukcji magnetowodów
Application of modern magnetic materials to magnetic cores
Autorzy:
Kwiczala, J.
Rodoń, F.
Cholewa, S.
Powiązania:
https://bibliotekanauki.pl/articles/157370.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
materiały amorficzne
rdzeń magnetyczny
przekładnik prądowy
amorphous materials
magnetic core
current transformer
Opis:
W artykule przedstawiono możliwości wykorzystania materiałów amorficznych w konstrukcji magnetowodów. Materiały te charakteryzują się bardzo dużą przenikalnością początkową oraz bardzo małą stratnością. Opisano możliwości zastosowania, np. w konstrukcji przekładników Ferrantiego, rdzeni kompozytowych - rdzeni złożonych z materiału tradycyjnego (żelazokrzem) o małej przenikalności i dużej indukcji nasycenia oraz materiału o dużej przenikalności magnetycznej i małej indukcji nasycenia (metglas).
The paper presents application of amorphous materials to construction of magnetic cores. These materials are characterized by very high initial relative permeability and very low losses. Application of composite cores to construction i.e of. the Ferranti earth-fault current transformer was presented. The composite core consisting of two toroidal cores made of silicon-iron steel (low permeability and high magnetic flux density saturation) and metglas tape (high permeability and low magnetic flux density saturation).
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 7/8, 7/8; 38-41
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ pomiaru symetrycznych i asymetrycznych prądów zwarciowych z zastosowaniem wielozakresowych przekładników prądowych w warunkach laboratorium zwarciowego
The system of measurement of symmetrical and asymmetric short circuit current with multi range current transformers in conditions of short-circuit testing laboratory
Autorzy:
Babiuch, Michał
Olak, Jan
Powiązania:
https://bibliotekanauki.pl/articles/267651.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
badania zwarciowe
pomiar prądów zwarciowych
przekładnik prądowy
short-circuit test
short-circuit current measurement
current transformer
Opis:
W artykule przedstawiono różne wymagania zawarte w normach przedmiotowych, dotyczące parametrów probierczych dla aparatury elektroenergetycznej i różnych rodzajów badań wykonywanych w laboratorium zwarciowym. Opisano wyposażenie badawczo pomiarowe Zwarciowni Instytutu Elektrotechniki w Warszawie (IEL). Przedstawiono układ pomiaru prądów zwarciowych przy użyciu nowo opracowanych przekładników. Opisano metodę sprawdzenia dokładności przekładników prądowych do pomiaru prądów zwarciowych i zamieszczono przykładowe wyniki i oscylogramy z badań. Układ został wdrożony i jest eksploatowany w Zwarciowni IEL.
The article contains an overview of various requirements for the parameters of the Short-Circuit Testing Laboratory: symmetrical and asymmetrical short-circuit currents, time constant for the disappearance of the constant short-circuit component, asymmetrical peak factor and various types of short-circuit tests performed on various devices operating in power systems, contained in different subject standards . The equipment of the Short-Circuit Testing Laboratory of the Electrotechnical Institute and the modernized test chamber No. 6 is described, equipped with new multi range current transformers and a modern measuring system for short-circuit current. The method of checking the accuracy of current transformers for measuring short-circuit currents is described and example oscillograms are given. The values of the adopted parameters of the transformers and the way of designing the test track are highlighted, enabling the simplification of preparatory works to carry out short-circuit tests and research organization. The article contains electrical diagrams of measurement systems, diagrams of current transformer windings and photograph of modernized test chamber No. 6.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 159-162
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Właściwości metody programowej korekcji błędów częstotliwościowych transformatora prądowego w zakresie nieliniowej pracy przy pomiarach mocy
Properties of the method of current transformer frequency error correction within the range of nonlinear operation for power measurements
Autorzy:
Furmankiewicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/157884.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przekładnik prądowy
błędy częstotliwościowe
korekcja błędów częstotliwościowych
current transformer
frequency errors
frequency error correction
Opis:
Artykuł dotyczy metody korekcji częstotliwościowych błędów modułu i błędów fazowych opracowanej dla liniowych obwodów wejściowych. Korekcja realizowana jest w sposób programowy w dziedzinie widmowej. Przedstawiono wyniki badań eksperymentalnych obrazujące skuteczność metody korekcji przy pomiarach mocy sygnałów w zakresie nieliniowej charakterystyki przetwarzania przekładnika prądowego. Wyniki badań wskazują, że możliwa jest korekcja błędów częstotliwościowych obwodów wejściowych przy pomiarach mocy również w zakresie nieliniowej pracy obwodów wejściowych.
The paper deals with the method for correction of dynamic module and phase errors of linear input circuits. The method is implemented in the spectral domain in a programmed manner using the FFT algorithm. Correction of the signal spectrum is based on frequency characteristics of the input circuit module and phase errors determined on the basis of previous measurements [1]. The method can be used for measuring the RMS value and power of signals. This paper presents the results of experiments showing the effectiveness of the correction method for measuring the power in the range of the current transformer nonlinear operation. Figs. 1a and 1b show the frequency characteristics of the module and phase errors of the current transformer used for tests. The block diagrams of the measuring systems used for examination of the correction effectiveness for measuring sinusoidal and non-sinusoidal waveforms are depicted in Figs. 2 and 3. The power measurement errors before and after correction for a sinusoidal waveform of frequency 50 Hz and 350 Hz and a resistive load are presented in Fig. 4a, while Fig. 4b shows the power measurement errors before and after correction for the phase angle between the voltage and current equal to 30 and 60 degrees. In Tab. 1 there are given the power measurement errors before and after correction for the waveform containing the first and third harmonic and a resistive load. In Tab. 2 there are compared the power measurement errors before and after correction for the waveforms similar to that of the thyristor voltage regulator and for a resistive load. The results show that it is possible to correct the frequency errors of current transformers when measuring the power in the range of the transformer nonlinear operation.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 9, 9; 767-769
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Universal Current Transformer for Accurate Measurement of Short-circuit Currents
Uniwersalny przekładnik prądowy do dokładnego pomiaru prądów zwarciowych
Autorzy:
Przybysz, J.
Olak, J.
Piątek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/397436.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
current transformer
aperiodic time constant
short circuit tests
przekładnik prądowy
aperiodyczna stała czasowa
badania zwarciowe
Opis:
The paper presents the design of a special current transformer developed by the Institute of Power Engineering in cooperation with TRANSFORMEX sp. z o.o. The aim of the project was to obtain current transformers allowing not only a thorough transformation of symmetrical currents – which is characteristic for typical current transformers, but also of asymmetrical shortcircuit currents containing an aperiodic component, which are not reproduced by classic current transformers. A current transformer has been developed with a range of short-circuit currents established from 1 kA to 50 kA, and short-circuit currents with an aperiodic component with a decay time constant up to 200 ms, peak value from 2.5 kA to 125 kA, assuming the possibility of five-fold repetition of short circuits with the same value and the same constant component polarity, with the assumed transformation accuracy.
W artykule przedstawiono konstrukcję specjalnego przekładnika prądowego opracowanego we współpracy Instytutu Energetyki z firmą TRANSFORMEX sp. z o.o. Celem pracy było uzyskanie przekładników prądowych umożliwiających nie tylko dokładną transformację prądów przemiennych ustalonych – co jest znamienne dla typowych przekładników prądowych, ale również niesymetrycznych prądów zwarciowych zawierających składową bezokresową, których klasyczne przekładniki prądowe nie odtwarzają. Opracowano przekładnik prądowy o zakresie prądów zwarciowych ustalonych od 1 kA do 50 kA oraz prądów zwarciowych ze składową bezokresową o stałej czasowej zanikania do 200 ms, o wartości szczytowej od 2,5 kA do 125 kA, przy przyjęciu możliwości pięciokrotnego powtarzania zwarć tej samej wartości i tej samej biegunowości składowej stałej, przy założonej dokładności transformacji.
Źródło:
Acta Energetica; 2017, 1; 101-106
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testery liczników energii elektrycznej podłączonych do sieci
Testers of energy meters connected to the power network
Autorzy:
Olencki, A.
Powiązania:
https://bibliotekanauki.pl/articles/153592.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
sprawdzanie liczników energii
testery liczników energii
licznik kontrolny
licznik wzorcowy
current transformer tester
potential transformer tester
power quality analyser
Opis:
Omówiono testery liczników energii elektrycznej podłączonych do sieci energetycznej i kluczowy problem tych testerów - specyfikację dokładności testera w szerokim zakresie dynamicznym napięć, prądów i mocy. Przedstawiono rozwój testerów w ciągu ostatnich kilkunastu lat i ich koncepcje do najnowszego zintegrowanego testera liczników z funkcjami testera przekładników i analizatora jakości energii. Z przedstawionej analizy wynika, że krajowe testery opracowane i produkowane w Zielonej Górze są zgodne z aktualnym stanem techniki na świecie a ich asortyment w pełni pokrywa aktualne potrzeby krajowych użytkowników bez konieczności korzystania z importu.
The paper presents an idea of portable energy meter testers called Portable Working Standard for Testing Electricity Meters which are used for testing single and three phase energy meters, current and potential instrument transformers and installations on site. The key issue of the tester accuracy specifications within the wide dynamic range of voltages, currents and power is discussed in Section 2. The accuracy specification for testers from Zielona Gora is given in Table 1. The table contains the concepts of testers beginning from three phase testers of 0,2 and 0,1 class (Calport 100 shown in Fig.2), economy single phase testers of 0,5 and 0,2 class (Caltest 10 shown in Fig.3), testers with additional function of three phase current and potential instrument transformer testing (Calport 100 Plus presented in Fig.4) to the newest integrated testers designed as three instruments in one compact case - the Energy Meter Tester and the Instrument Transformer Tester and the Power Quality Analyser (PWS 3.3 of MTE Switzerland and Caltest 300 of Calmet Poland presented in Fig.5). The analysis of technique state shows that a good position in the world market in portable energy meter testers is still kept in Poland.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 12, 12; 1557-1560
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies