Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "crt-d" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Pozawałowa niewydolność serca – optymalne leczenie według współczesnych standardów – opis przypadku
Congestive heart failure – optimal treatment according to contemporary guidelines – the case report
Autorzy:
Kaźmierczak-Dziuk, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1031858.pdf
Data publikacji:
2011
Wydawca:
Medical Communications
Tematy:
CRT-D
cardiac resynchronization therapy
cardioverter-defibrillator
heart failure
kardiowerter-defibrylator
myocardial infarction
zawał serca
niewydolność serca
terapia resynchronizująca
crt-d
Opis:
Coronary artery disease (CAD) or ischaemic heart disease caused by atherosclerosis is the most common form of cardiovascular disease. CAD leads to acute coronary syndrome which is the clinical syndrome caused by new or growing interruption or occlusion of blood supply to a part of the heart, causing heart cells to die and myocardial infarction. Myocardial infarction destroys normal myocardium and leads directly to heart failure. This paper describes the case of male patient who in the age of 56 suffered from huge myocardial infarction, which caused important heart contractility disturbances, essential reduction in ejection fraction and provoked symptomatic heart failure. Despite fast revascularization and optimal pharmacotherapy patient remained in class III NYHA classification. As the next step in therapeutic procedure patient underwent the implantation of cardioverter-defibrillator with cardiac resynchronization. After 2 years from this procedure big clinical progress was observed. Now patient remains in class I NYHA classification. Also improvement of left ventricle function in echocardiography was observed. Correct qualification to applied treatment determined its safety and legitimacy, and resulted in good clinical effect of treatment the patient with heart failure. Such effectiveness is very important for the patient’s follow-up and good prognosis due to cardiovascular risk reduction.
Choroba wieńcowa, czyli choroba niedokrwienna serca na podłożu miażdżycy tętnic wieńcowych, jest najbardziej rozpowszechnioną chorobą układu sercowo-naczyniowego. Bezpośrednie następstwo miażdżycy tętnic wieńcowych stanowi ostry zespół wieńcowy, będący zespołem klinicznym spowodowanym przez świeże lub narastające ograniczenie bądź całkowite ustanie przepływu krwi przez tętnicę wieńcową, doprowadzające do martwicy mięśnia sercowego, czyli zawału serca. Zawał serca powodujący zniszczenie prawidłowo działającego myocardium prowadzi bezpośrednio do rozwoju niewydolności serca. W pracy przedstawiono przypadek pacjenta, który w wieku 56 lat przebył rozległy zawał serca, powodujący głębokie zaburzenia kurczliwości, istotne obniżenie frakcji wyrzutowej i objawy niewydolności serca. Pomimo podjętych w trybie przyspieszonym procedur rewaskularyzacyjnych oraz optymalnej farmakoterapii chory nadal pozostawał w III klasie czynnościowej według NYHA. Jako kolejny etap leczenia zakwalifikowano chorego do wszczepienia kardiowertera-defibrylatora z funkcją resynchronizacji. Po dwóch latach od wdrożenia elektroterapii zaobserwowano istotną klinicznie poprawę stanu chorego (obecnie znajduje się w I klasie czynnościowej według NYHA), a także istotną poprawę funkcji lewej komory w badaniu echokardiograficznym. Prawidłowa kwalifikacja chorego do zastosowanego leczenia warunkowała jego bezpieczeństwo i zasadność, a przede wszystkim skutkowała dobrym wynikiem leczenia niewydolności serca. Taka skuteczność terapii nie pozostanie bez wpływu na dalsze rokowanie pacjenta, powodując istotną redukcję ryzyka sercowo-naczyniowego.
Źródło:
Pediatria i Medycyna Rodzinna; 2011, 7, 3; 241-246
1734-1531
2451-0742
Pojawia się w:
Pediatria i Medycyna Rodzinna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prediction of the cumulated dose for external beam irradiation of prostate cancer patients with 3D-CRT technique
Autorzy:
Giżyńska, M.
Blatkiewicz, D.
Czyżew, B.
Gałecki, M.
Gil-Ulkowska, M.
Kukołowicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/147543.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
3D-CRT
cumulative dose
dose prediction
setup error
individualized margins
Opis:
Nowadays in radiotherapy, much effort is taken to minimize the irradiated volume and consequently minimize doses to healthy tissues. In our work, we tested the hypothesis that the mean dose distribution calculated from a few fi rst fractions can serve as prediction of the cumulated dose distribution, representing the whole treatment. We made our tests for 25 prostate cancer patients treated with three orthogonal fi elds technique. We did a comparison of dose distribution calculated as a sum of dose distribution from each fraction with a dose distribution calculated with isocenter shifted for a mean setup error from a few fi rst fractions. The cumulative dose distribution and predicted dose distributions are similar in terms of gamma (3 mm 3%) analysis, under condition that we know setup error from seven fi rst fractions. We showed that the dose distribution calculated for the original plan with the isocenter shifted to the point, defi ned as the original isocenter corrected of the mean setup error estimated from the fi rst seven fractions supports our hypothesis, i.e. can serve as a prediction for cumulative dose distribution.
Źródło:
Nukleonika; 2016, 61, 1; 15-18
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of set-up verification with the analysis of systematic and random errors in radiotherapy - a study of the Great Poland Cancer Centre
Autorzy:
Szczurek, Ł.
Skrobała, A.
Piotrowski, T.
Jodda, A.
Powiązania:
https://bibliotekanauki.pl/articles/147744.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electronic portal devices
positioning patient
three-dimensional-conformal radiation therapy (3D-CRT)
intensity-modulated radiation therapy (IMRT)
oncology
Opis:
The aim of this study was the examination of influence of location tumors and methods of immobilizing on values of geometrical errors during treatment, and the analysis of set-up errors in reference to the method of irradiation in three groups of patients before and after corrections. This study included three groups of patients with prostate cancer (59 patients, 277 portal images), head and neck (60 patients, 285 portal images) and brain tumor (45 patients, 175 portal images). Ratios of IMRT vs. 3D-CRT were respectively: in I group 76% vs. 24%, in II group 95% vs. 5% and III group 83% vs. 17%. Set-up errors were compared in reference to the technique of irradiation and stage of treatment. The displacements were significantly higher in the first group compared with head, neck and brain tumors; 5.66, 4.05, 3.93 mm, respectively. The values of the vector lengths were significantly dependent on the type of irradiation technique (3D-CRT vs. IMRT) only in the first group (p < 0.001). The average of vector length in I, II and III group were significantly reduced from; 5.67, 4.02, 3.91 mm to 5.13, 3.63, 3.57 mm after correction, respectively. The Spearman test is indicating a low negative correlation between set-up errors and the following fractions. The applied methods of patients positioning with prostate cancer produce a worse repeatability than the ones used for patients with head, neck and brain cancers. Portal verification reduces values of set-up errors. Significant differences in the magnitude of displacements before and after correction were observed. No significant differences between value of displacement and number of fraction were revealed.
Źródło:
Nukleonika; 2008, 53, 4; 167-171
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies