Wyszukujesz frazę "cooling power" wg kryterium: Temat


Tytuł:
Functioning Efficiency of the Central Air-Conditioning System on the Selected Example
Autorzy:
Szlązak, Nikodem
Swolkień, Justyna
Powiązania:
https://bibliotekanauki.pl/articles/2064267.pdf
Data publikacji:
2020
Wydawca:
STE GROUP
Tematy:
air conditioning
climate hazard
cooling power
klimatyzacja
zagrożenie klimatyczne
moc chłodzenia
Opis:
One of the particularly significant threats during exploitation is the climatic threat, which is associated with an increase in the overall costs that are allocated to combating it. The rise in the virgin temperature of the rock mass by 1oC increases the demand for the required cooling capacity to be taken from the air. The publication assesses the effectiveness of the air-conditioning installation by testing its operation on a selected example. The assessment of the efficiency of the air-conditioning installation for a selected hard coal mine showed that none of the five tested coolers achieved the maximum assumed rated power. The use of total power (7.5 MW) in mining excavations was less than 50% and amounted to η = 0.472%. The research showed that the main reason for obtaining low cooling parameters is the inability to locate them in the place of the highest air temperatures. The other problem is an insufficient airflow rate of cooling water supplied to the coolers at too high temperature. The above considerations indicated that the cooling power from built-in air- conditioning systems is not properly and effectively used. Improving the efficiency of its functioning is possible by proceeding research that will eliminate the above factors and by using air conditioning equipment, taking into account the periodic audit of their work to reduce electricity consumption.
Źródło:
New Trends in Production Engineering; 2020, 3, 1; 41--55
2545-2843
Pojawia się w:
New Trends in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kierunek przepływu strug nawiewno-wywiewnych a ruch powietrza w strefie przebywania tuczników
Inlet-outlet flow streams direction and the air movement in the porker zone
Autorzy:
Żelazny, H.
Powiązania:
https://bibliotekanauki.pl/articles/286267.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
wentylacja mechaniczna
ruch powietrza
siła ochładzania
trzoda chlewna
mechanical ventilation
air movement
cooling power
pig
Opis:
Działające w pomieszczeniach inwentarskich urządzenia wentylacyjne powodują ruch powietrza, który może przy nadmiernych prędkościach zniszczyć zewnętrzną warstwę buforową atmosfery przylegającą do skóry zwierząt, przez co pozbawione są one naturalnej izolacji ciepłochronnej. Obawy o nadmierne ochładzanie organizmów budzą szczególnie układy z poziomym przepływem powietrza wentylacyjnego tuż nad strefą przebywania zwierząt. Badania wpływu układów wentylacji mechanicznej o identycznej wydajności i zróżnicowanym przepływie powietrza na prędkość strug nawiewno-wywiewnych przeprowadzono w trzech budynkach fermowych. Na podstawie pomiarów instrumentalnych stwierdzono, że system przewietrzania obiektów inwentarskich z wentylatorami osiowymi zamontowanymi w naprzeciwległych ścianach nie generował nadmiernych prędkości ruchu powietrza w kojcach. Ponadto w dodatkowej analizie obliczeniowej siły ochładzania, zarówno w rozwiązaniu wentylacji w układzie pionowym, jak i poziomym, jej wartości nie odbiegały od zalecanego przedziału.
The research as to the influence of mechanical ventilation systems of identical efficiency and differentiated air flow on the speed of inlet and outlet streams was done in three farm buildings. Following the instrumental measurements it was discovered that the system of airing farm facilities with axis ventilators assembled on the opposite walls did not generate excessive air speed in pigpens. Moreover, in the additional calculation analysis of the cooling speed, both in the ventilation in the vertical and horizontal system, its values did not diverge from the recommended range.
Źródło:
Inżynieria Rolnicza; 2005, R. 9, nr 1, 1; 185-191
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the GMC-1000 and GMC-2000 mine cooling units for central air-conditioning in underground mines
Zastosowanie górniczego urządzenia chłodniczego GMC-1000 i GMC-2000 w centralnej klimatyzacji kopalń podziemnych
Autorzy:
Wojciechowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/218941.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
centralna klimatyzacja kopalń podziemnych
agregat chłodniczy
parownik
skraplacz
wydajność chłodnicza
obieg lewobieżny
central air conditioning of underground mines
cooling unit
evaporator
condenser
cooling power
Opis:
The paper describes the design and results of operating measurements of the GMC-1000 and GMC- 2000 Mine Cooling Units. The first part describes the design of the cooling unit and its key components: the chiller, evaporator, condenser, oil cooler, evaporative water cooler and gallery air cooler. The possibilities of use in central air conditioning systems of underground mines are described. The second part discusses the results of the workstation and operating measurements and determines the coefficients for evaluating the performance of the mine cooling unit.
Wraz ze wzrostem głębokości eksploatacji pogarszają się warunki pracy w wyrobiskach podziemnych, a w szczególności warunki klimatyczne związane ze wzrostem temperatury. Przy temperaturach pierwotnych górotworu przekraczających 40°C utrzymanie temperatury w wyrobiskach eksploatacyjnych poniżej wartości 28°C, uznawanej za wartość dopuszczalną ze względu na warunki pracy załogi, wymaga, oprócz zwiększonej wydajności wentylacji wyrobisk, także ich klimatyzacji. Można znaleźć wiele prac dotyczących tych zagadnień. Problemów klimatyzacji i chłodzenia wyrobisk dotyczą między innymi prace: Filka i jego zespołu (1999, 2002, 2004, 2006), Łuska i Nawrata (2002), Kalukiewicza i jego zespołu (2008). W krajowym górnictwie dotyczy to zarówno kopalń węgla kamiennego, jak też rud miedzi. W większości przypadków konieczność utrzymania wymaganych warunków klimatycznych w rejonie, przy jednoczesnym nacisku na ekonomiczną stronę procesu pozyskiwania kopalin, powodują konieczność stosowania klimatyzacji grupowej przy zastosowaniu urządzeń o dużej wydajności zlokalizowanych na dole kopalni. W niniejszym artykule omówiono wybrane zagadnienia doboru urządzeń klimatyzacji grupowej na przykładzie urządzenia chłodniczego GMC-1000 i GMC-2000. Konstrukcję urządzenia opracowano w firmie EUROTECH Sp. z o.o. przy współpracy z pracownikami Katedr Maszyn Górniczych Przeróbczych i Transportowych oraz Systemów Energetycznych i Urządzeń Ochrony Środowiska Wydziału Inżynierii Mechanicznej i Robotyki Akademii Górniczo-Hutniczej w Krakowie w ramach projektu dofinansowanego przez Ministerstwo Nauki i Szkolnictwa Wyższego. Górnicze urządzenie chłodnicze jest przeznaczone do chłodzenia powietrza wentylacyjnego w chodnikach wydobywczych kopani podziemnych. Znajduje zastosowanie wszędzie tam, gdzie panują trudne warunki wydobywcze powodowane między innymi dużymi obciążeniami cieplnymi. Wysokie temperatury utrudniają prace górnicze. Powodują konieczność skrócenia czasu przebywania pracowników w rejonach o najwyższych temperaturach. W połączeniu z zapyleniem i wilgotnością stanowią istotny problem przy eksploatacji maszyn i urządzeń ścianowych. Agresywna atmosfera powoduje znacznie szybsze zużycie sprzętu. Problemy te uzasadniają konieczność stosowania systemów chłodzenia powietrza bezpośrednio w rejonach, w których prowadzone jest wydobycie. Górnicze urządzenie chłodnicze GMC stanowi kompletny system chłodzenia powietrza wentylacyjnego w chodnikach wydobywczych. Realizowane zadania powodują, że system ten musi być rozbudowany pod względem technicznym jak również przestrzennym. Część zadań stawianych przed urządzeniem chłodniczym jest realizowana w znacznej odległości od chodników wydobywczych. Dotyczy to przygotowania wody chłodzącej, która służy do schładzania powietrza w chłodnicach ścianowych. Woda z rejonu jej schładzania przepływa rurociągami do rejonów wydobywczych, gdzie jest wykorzystywana do chłodzenia powietrza. Urządzenie pracuje w układzie zamkniętym. Należy zwrócić uwagę, że system chłodzenia musi spełniać wszystkie wymagania określone przez odpowiednie przepisy górnicze dotyczące zasad eksploatacji i bezpieczeństwa. Podstawowymi elementami górniczego urządzenia chłodniczego są następujące aparaty (rys. 1): agregat chłodniczy, chłodnica wyparna wody, chłodnica chodnikowa powietrza. Wymienione aparaty są urządzeniami, w których następują przepływy ciepła. Mają one różny charakter w zależności od przeznaczenia danego elementu. Urządzenie chłodnicze jest uzupełnione dodatkowymi elementami, które są niezbędne do jego prawidłowego funkcjonowania. Do grupy tej należą maszyny z układami napędowymi wymuszające przepływy czynników w poszczególnych wymiennikach ciepła. Mamy tutaj wentylatory i sprężarki czynników gazowych oraz pompy do wody jak również cieczy technologicznych. Urządzenie chłodnicze musi być wyposażone w dodatkowy sprzęt i aparaturę kontrolno-pomiarową. Konieczne są filtry do gazu i cieczy. Czujniki przepływu, temperatury i ciśnienia. Schemat górniczego urządzenia chłodniczego z opisem poszczególnych elementów jest pokazany na rysunku 1. W ramach projektu celowego nr 6 ZR8 2007C/06934 wykonane zostało Górnicze Urządzenie Chłodnicze przeznaczone do klimatyzacji grupowej (centralnej) w kopalniach podziemnych. Konstrukcję urządzenia opracowano w firmie EUROTECH Sp. z o.o. przy współpracy z pracownikami Katedry Maszyn Górniczych Przeróbczych i Transportowych oraz Katedry Systemów Energetycznych i Urządzeń Ochrony Środowiska Wydziału Inżynierii Mechanicznej i Robotyki Akademii Górniczo-Hutniczej w Krakowie. Prototyp urządzenia był badany w WUCH „PZL - Dębica” S.A., następnie przeszedł próby ruchowe w O. ZG „ Rudna”. Obecnie kilka egzemplarzy górniczego urządzenia chłodniczego jest eksploatowanych w kopalniach węgla kamiennego. Prototyp urządzenia GMC-1000 miał moc chłodniczą 1000 kW, wykonano również egzemplarz GMC-2000 o mocy chłodniczej 2000 kW. W tabelach 1-3 przedstawiono wyniki pomiarów agregatu GMC-1000 przeprowadzonych na prototypie oraz wyniki uzyskane w czasie eksploatacji w Kopalni Węgla „Rydułtowy-Anna”, tabela 4 zawiera wyniki uzyskane w czasie eksploatacji urządzenia GMC-2000 w Kopalni Węgla „Bielszowice”. Urządzenie chłodnicze w kopalni „Rydułtowy- Anna” pracuje od lutego 2009. W trakcie prób, za pomocą regulatora wydajności, zmieniano wydajność sprężarki chłodniczej. Regulator wydajności zapewnia płynną regulację strumienia od 0% do 100%. Ilość sprężanych par czynnika R134a w danej chwili, a tym samym zmianę wydajności sprężarki, uzyskuje się za pomocą sterowanego hydraulicznie suwaka regulacji wydajności. Temperatura wody lodowej dopływającej do parownika (tw5) była stabilna w trakcie poszczególnych pomiarów, ale specyfika stanowiska nie pozwalała na utrzymanie stałej wartości temperatury dla kolejnych prób. Wynikał stąd rozrzut wartości tw5 w granicach 11,1°C do 17,4°C. Kolejną wielkością regulowaną była temperatura parowania to (cienienie parowania), która w trakcie pomiarów była zmieniana w granicach -1,4°C do +1,4°C. Badania eksploatacyjne miały na celu sprawdzenie przydatności agregatu do pracy w warunkach kopalnianych. Poszczególne próby były realizowane przy różnych wartościach nastaw i wielkości wejściowych układu. Brak możliwości ustalenia wartości wybranych parametrów wynikał z faktu przeprowadzania pomiarów w czasie prowadzenia prac wydobywczych w O.ZG „Rudna”. Wartości wielkości wejściowych zależały od chwilowego stanu obciążeń i warunków otoczenia. Temperatura wody lodowej dopływającej do parownika była stabilna w trakcie poszczególnych pomiarów (tylko te były przyjmowane jako reprezentatywne), ale zmieniała się ze względu na współpracę agregatu z działającymi w wyrobisku chłodnicami powietrza. Temperatura tw5 zmieniała się w granicach 12,7°C÷19,1°C. Kolejną wielkością regulowaną była temperatura parowania to (ciśnienie parowania), która w trakcie pomiarów zmieniała się w granicach -1,1°C. Uzyskane przez górniczą maszynę chłodniczą GMC-1000 i GMC-2000 wartości parametrów pracy na stanowisku badawczym i przy próbach ruchowych potwierdziły przyjęte założenia projektowe. Wartości parametrów założone na etapie projektowania zostały osiągnięte w trakcie badań stanowiskowych. Założona moc chłodnicza wynosiła 1000 kW, w czasie pomiarów udało się osiągnąć moc chłodniczą 1250 kW. Moc ta została osiągnięta przy 100% nastawie suwaka regulującego przepływ czynnika chłodniczego przez sprężarkę i spadku temperatury wody lodowej w parowniku 11,4 K. Wynik ten daje 25% zapas mocy chłodniczej względem mocy chłodniczej nominalnej, spadek temperatury wody lodowej, w tym przypadku, jest mniejszy o 15,5% w stosunku do założonego. Zapas mocy jest większy w stosunku do niedoboru spadku temperatury oznacza to, że możliwe jest osiągnięcie wymaganego spadku temperatury nawet przy mniejszych mocach chłodniczych. Stwarza to możliwość regulacji parametrów pracy urządzenia chłodniczego w szerokim zakresie. W kilku pomiarach uzyskane temperatury schłodzenia wody były korzystniejsze niż to założono na etapie projektowania GMC. Szerokie przedziały zmienności wartości parametrów stwarzają duże możliwości sterowania pracą górniczych maszyn chłodniczych GMC-1000 i GMC-2000. Osiągnięcie wymaganego stopnia schłodzenia wody lodowej pozwoli na wymagane schłodzenie powietrza w chłodnicy ścianowej. Rezultaty uzyskane w czasie prób stanowiskowych, ruchowych i eksploatacji w kopalniach pozwalają na stwierdzenie, że górnicza maszyna chłodnicza może być eksploatowana w centralnych układach klimatyzacyjnych kopalń podziemnych.
Źródło:
Archives of Mining Sciences; 2013, 58, 1; 199-216
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ewolucja kryteriów wyboru i wartości temperatury obliczeniowej powietrza zewnętrznego dla ogrzewnictwa w Polsce
Autorzy:
Narowski, P
Powiązania:
https://bibliotekanauki.pl/articles/363008.pdf
Data publikacji:
2011
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
temperatury obliczeniowe powietrza zewnętrznego
projektowanie zapotrzebowania na moc do ogrzewania i chłodzenia budynków
design temperatures of air
thermal power demand
cooling power demand
Opis:
Wartości temperatury obliczeniowej powietrza zewnętrznego mają podstawowe znaczenie w procesie wyznaczania zapotrzebowania na moc cieplną dla budynków oraz wpływają na proces projektowania i wymiarowania urządzeń ogrzewczych. W Polsce ostania modyfikacja normy dotyczącej obliczeniowych temperatur zewnętrznych dla ogrzewnictwa miała miejsce w 1982 roku, jakkolwiek wartości te nie zmieniały się od kilkudziesięciu lat. Dostępne obecnie dane meteorologiczne z wielolecia dla 61 stacji meteorologicznych, normy europejskie dotyczące danych klimatycznych wykorzystywanych w budownictwie, komputerowe systemy symulacji energetycznych budynków oraz coraz nowocześniejsze technologie stosowane w budownictwie zmuszają do zastanowienia się nad weryfikacją obecnie wykorzystywanych temperatur obliczeniowych dla ogrzewnictwa. W prezentowanym artykule przedstawione zostaną zmiany w doborze kryteriów wyboru oraz wartości temperatury obliczeniowej dla ogrzewnictwa w Polsce na przestrzeni lat.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2011, T. 6, nr 3, 3; 61-67
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości wykorzystania płytkich wód podziemnych kościerskiej wyspy morenowej do sezonowego magazynowania chłodu i ciepła
Assessment of the shallow groundwater potential of the Kościerzyna morainic island for cold and heat seasonal energy storage
Autorzy:
Lemoine, Gérard
Powiązania:
https://bibliotekanauki.pl/articles/2076126.pdf
Data publikacji:
2021
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
magazynowanie energii cieplnej
ATES
pompa ciepła na wodę gruntową
moc chłodnicza brutto
powiat kościerzyński
aquifer thermal energy storage
groundwater heat pump
gross cooling power
Kościerzyna district
Opis:
Low-temperature aquifer thermal energy storage (LT-ATES) is widely used on an industrial scale in the Netherlands. In Poland, where the Polish Lowlands were recently typed as a promising area in this respect, this method has not yet been tested. Because of the complex structure of subsurface geological formations of most parts of these lowlands, assessment of the technical and economic feasibility of this type of energy storage requires extensive investigations. In this study, the ATES potential of an area of a geodetic precinct size was assessed using the basic documentation, especially the “Hydrogeological Map of Poland” with explanations. As a study area, the Kościerzyna morainic island was selected which is the main pole of development of southern Kashubia. The results of the assessment show that, in addition to economic advantages, this area has favourable hydrogeological conditions for LT-ATES due to its location between the Kashubian Lake District morainic complex and the Tuchola Forest outwash plain. In this area, subject to appropriate engineering research, the investment of LT-ATES systems with a few megawatt cooling capacity is entirely possible. This paper presents the most important conclusions of the study which was submited to the archives of the Polish Geothermal Association in Kraków at the beginning of June 2020 (Lemoine, 2020).
Źródło:
Przegląd Geologiczny; 2021, 69, 10; 697--701
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cooling water flow influence on power plant unit performance for various condenser configurations setup
Autorzy:
Dobkiewicz-Wieczorek, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/2091367.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cooling water
power plant efficiency
cooling water flow control
CHP plant
efficiency
Opis:
This paper presents the influence of cooling water regulation on power plant net efficiency. It was examined whether, for the non-nominal low-pressure turbine load, it is justified to reduce the cooling water pump load, and how it would affect the unit net efficiency. Calculations for two types of power units were carried out: with condensing and extraction-condensing turbine. The tested condensing power plant consists of three surface condensers. The calculation included four condensers’ connections set up on the cooling water side to check how the cooling water system pressure drop affects the net unit performance. The result has confirmed that implementing serial connection decreases net efficiency when cooling water flow regulation is used, but the mixed connection should be applied when pump load is not controlled. It was proved that the cooling water flow control gives a profit for both units. Net efficiency for combined heat and power plant can be improved by 0.1–0.5 pp, the gain is remarkable below 60% of the low-pressure turbine part load. Flow control implementation in the unit with condensing turbine water control gives a similar profit just below 80% of the turbine load. Next, an influence of the additional limitations of a cooling water system (minimal total pump head, cooling tower) affecting the feasibility of implementing the water control has been considered. Applying a multi-cell forced draft cooling tower does not have a significant impact on results, but when a natural draft cooling tower is used, the flow control range is strongly reduced.
Źródło:
Archives of Thermodynamics; 2022, 43, 1; 141--167
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation into Increasing the Motor-Drivable Current Using a Thermoelectric Cooling Module
Autorzy:
Morikawa, Kazuma
Katsura, Seiichiro
Powiązania:
https://bibliotekanauki.pl/articles/2175939.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
motor
cooling
thermoelectric effect
Peltier device
high power
Opis:
To enhance the performance of humanoids, mobile robots and manipulators, motors are desired to be able to provide high torque without relying on gears. To be able to drive joint motors with high output, the current value that can flow needs to be increased. However, the heat generated by the high current drive can cause motor failure, so cooling is necessary. We used thermoelectric cooling as a new cooling method for high-power drive of motors. By developing a thermoelectric cooling module for motors and conducting experiments, the effectiveness of thermoelectric cooling was verified. In the experiment, the motor was kept running at a high current for a long period of time. The comparison with the motor alone or with water cooling showed that the thermoelectric cooling module can significantly reduce the rise in temperature of the motor. Furthermore, based on the results of the voltage value measurements, it was expected that the increase in coil resistance due to higher coil temperatures would be kept lower than in other cases. The effect on rise in internal temperature was also considered to be greater than that of water cooling. These experimental results show that the thermoelectric cooling module can be used to increase the upper limit of the current at which the motor is continuously driven.
Źródło:
Power Electronics and Drives; 2022, 7, 42; 279--289
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The cooling rate of the heated vapor compression cycle in case of using refrigerants R134a, R22, and R600a
Autorzy:
Abd-Elhady, Mohamed Salama
Melad, Emmanoueil Bishara
Abd-Elhalim, Mohamed
Seif Alnasr, Ahmed
Powiązania:
https://bibliotekanauki.pl/articles/1845463.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
compression
cycle
power saving
refrigerant
refrigerating cycle
cooling rate
Opis:
The most power consuming part in the vapor compression cycle (VCC) is the gas compressor. Heating the refrigerant under constant volume after the compressor increases the condenser pressure, which consequently increases the cooling rate of the VCC. This study examined the influence of heating different refrigerants, i.e. R143a, R22, and R600a on the cooling rate of the VCC. Four experiments have been performed: the first experiment is a normal VCC, i.e. without heating, while in the second, third, and fourth experiments were carried out to raise the temperature of the refrigerant to 50◦C, 100◦C, and 150◦C. It has been found that heating raises the refrigerant pressure in VCC and thereby improves the refrigerant’s mass flow rate resulting in an improvement in the cooling power for the same compressor power. Heating the refrigerant after the mechanical compressor increases the temperature of the condenser as well as the temperature of the evaporator when using refrigerant R134a, which prevents the refrigeration cycle to be used in freezing applications, however using refrigerant R22 or refrigerant R600a promotes the heated VCC to be used in freezing applications. Refrigerant R600a has the lowest operating pressure compared to R134a and R22, which promotes R600a to be used rather than R134a and R22 from a leakage point of view.
Źródło:
Archives of Thermodynamics; 2021, 42, 2; 11-30
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Turbine stage expansion model including internal air film cooling and novel method of calculating theoretical power of a cooled stage
Autorzy:
Trawiński, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2134930.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gas turbine
expansion line
air film cooling
theoretical stage power
Opis:
Systematic attempts to maximise the efficiency of gas turbine units are achieved, among other possibilities, by increasing the temperature at the inlet to the expansion section. This requires additional technological solutions in advanced systems for cooling the blade rows with air extracted from the compressor section. This paper introduces a new mathematical model describing the expansion process of the working medium in the turbine stage with air film cooling. The model includes temperature and pressure losses caused by the mixing of cooling air in the path of hot exhaust gases. The improvement of the accuracy of the expansion process mathematical description, compared with the currently used models, is achieved by introducing an additional empirical coefficient estimating the distribution of the cooling air along the profile of the turbine blade. The new approach to determine the theoretical power of a cooled turbine stage is also presented. The model is based on the application of three conservation laws: mass, energy and momentum. The advantage of the proposed approach is the inclusion of variable thermodynamic parameters of the cooling medium. The results were compared with the simplified models used in the literature: separate Hartsel expansion, mainstream pressure, weighted-average pressure and fully reversible. The proposed model for expansion and the determination of theoretical power allows for accurate modelling of the performance of a cooled turbine stage under varying conditions.
Źródło:
Archives of Thermodynamics; 2022, 43, 3; 3--27
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of heat transfer during pool boiling on minifins surface coated with carbon nanotubes
Autorzy:
Strąk, E.
Pastuszko, R.
Kłosowiak, R.
Urbaniak, R.
Powiązania:
https://bibliotekanauki.pl/articles/175588.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pool boiling
carbon nanotube
heat transfer coefficient
power
electronic cooling
Opis:
The article describes the study of heat transfer during pool boiling on minifins surface coated with nanostructure. This is a molecular level technology used in engineering or mechanical factory. A surface with carbon nanotubes (CNTs) is highly effective in reducing the superheat incipience and enhancing both the heat flux and heat transfer coefficient. The paper focuses on the comparison of the surfaces, on which pool boiling heat transfer occurs, i.e., on minifins coated with carbon nanotubes (MF+N) with surfaces formed by sintering the woven copper wire mesh to the minifins tips (MF+M) and with plain minifins surface (MF). The experiments were carried out for two boiling fluids: water and ethyl alcohol. The purpose of the presented study was to find out which of those tested surfaces and fluids could be the best alternative for use in the cooling of electronic devices and which surfaces could be used as thermosyphon or heat pipe evaporator.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2015, 128; 59-72
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessing the Solar Power Plant Efficiency Degradation Resulting from Heating
Autorzy:
Lavrik, A.
Yakovleva, E.
Lеskov, A.
Powiązania:
https://bibliotekanauki.pl/articles/124651.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
photoelectric module
PEM
solar power plant
performance coefficient
heating
cooling
Opis:
Renewable power sources (RPS) play an ever growing role in power production. With the green power cost decreasing, the RPS share (including hydro power plants) in power production grows fast. Using RPS in supplying power to various facilities reduces the CO2 emission into atmosphere, thus reducing the greenhouse effect and being a fundamental factor in fighting the global warming. Every type of RPS possesses certain drawbacks that need to be eliminated. RPS units do have disadvantages, too, including low efficiency coefficient, and low specific power. However, there is the need for specific technological conditions. The present work describes the issue of photoelectric module heating. Photoelectric module heating results in both lower output voltage and module aging acceleration. The present work offers the method for assessing the practicability of development and implementation of solar power cell module active cooling systems, based on the photoelectric module daily performance schedules, drawing on statistic meteorological data collected over many years, and also it presents the brief description of various methods for cooling photoelectric modules.
Źródło:
Journal of Ecological Engineering; 2018, 19, 3; 115-119
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of wet cooling tower replacement by Heller cooling tower in a power plant
Autorzy:
Malekmohamadi, Mohamad Hasa
Ahmadikia, Hossein
Golmohamadi, Siavas
Khodadadi, Hamed
Powiązania:
https://bibliotekanauki.pl/articles/27309880.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
Heller cooling tower
wet cooling tower
condenser
power plant
wieża chłodnicza Hellera
mokra wieża chłodnicza
skraplacz
elektrownia
Opis:
Water resources are the main component of natural systems affected by climate change in the Middle East. Due to a lack of water, steam power plants that use wet cooling towers have inevitably reduced their output power. This article investigates the replacement of wet cooling towers in Isfahan Thermal Power Plant (ITPP) with Heller natural dry draft cooling towers. The thermodynamic cycle of ITPP is simulated and the effect of condenser temperature on efficiency and output power of ITPP is evaluated. For various reasons, the possibility of installing the Heller tower without increasing in condenser temperature and without changing the existing components of the power plant was rejected. The results show an increase in the condenser temperature by removing the last row blades of the low-pressure turbine. However, by replacing the cooling tower without removing the blades of the last row of the turbine, the output power and efficiency of the power plant have decreased about 12.4 MW and 1.68 percent, respectively.
Źródło:
Archive of Mechanical Engineering; 2023, LXX, 1; 129--149
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal-flow Study of Closed Cooling System with Cooling Towers
Badania cieplno-przepływowe zamkniętego układu chłodzenia z chłodniami kominowymi
Autorzy:
Regucki, P.
Lewkowicz, M.
Krzyżyńska, R.
Powiązania:
https://bibliotekanauki.pl/articles/1813715.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
power plant
closed cooling system
counter flow wet cooling tower
elektrownia
zamknięty układ chłodzenia
przeciwprądowa mokra chłodnia kominowa
Opis:
The paper presents the thermal-flow study of closed cooling system with special emphasis on the working parameters of the cooling tower. The uniqueness of the analysis lays in measurement done inside the working cooling tower to identify thermal-flow processes across its radius. Next, the analysis of a cooling water temperature drop, in the cooling system cooperated with a set of cooling towers, is considered. As an example of these studies there are proposed the optimal cooling water flow rates between two cooling towers to achieve the highest possible water temperature difference in cooling system.
W pracy przedstawiono cieplno-przepływowe badania zamkniętego układu chłodzenia ze szczególnym uwzględnieniem parametrów pracy chłodni kominowych. Unikalność analizy polega na pomiarze wykonanym wewnątrz pracującej chłodni kominowej w celu identyfikacji procesów wymiany ciepła i masy wzdłuż jej promienia. Następnie przeanalizowano stopień schłodzenia wody cyrkulującej w układzie chłodzenia współpracującym z zespołem chłodni kominowych. Jako przykładowy wynik tych badań zaproponowano dobór optymalnych strumieni przepływu wody chłodzącej w układzie dwóch chłodni kominowych, pozwalający uzyskać możliwie najwyższy spadek temperatury (stopień schłodzenia) cyrkulującej wody.
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 1; 342-357
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of cooling water temperature on the performance of a BWR nuclear power plant
Autorzy:
Laskowski, Rafał
Theimech, Mohamad
Uzunow, Nikołaj
Powiązania:
https://bibliotekanauki.pl/articles/2195750.pdf
Data publikacji:
2021
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
nuclear power plant
cooling system
cooling water temperature
boiling water reactor
BWR
elektrownia jądrowa
układ chłodzenia
temperatura wody chłodzącej
reaktor wrzący
Opis:
Although PWR reactors make up the large majority of the world's nuclear power plants, BWR reactors also have a share in this industry. It is difficult to find data on the performance of a BWR power plant in off-design and variable load conditions in the literature. Therefore, the paper presents how cooling water temperature affects the efficiency and power output of a BWR unit. The qualitative effect of changes and the trend related to the effect of cooling water temperature on the performance of the power plant are known, but the quantitative effect has to be determined for specific power units. Depending on the location of the nuclear power plant, various temperatures of cooling water for use in condensers and thus various operating conditions of the cooling system can be achieved. To analyze how cooling water temperature affects the performance of the power unit, a model of a BWR power plant was developed using the Ebsilon software. The model was based on data provided in [1] concerning LaSalle County Nuclear Generating Station. Calculations showed that within the examined range of cooling water temperatures at the condenser inlet between 10 and 28oC the gross power output of the unit decreases by 91.405 MW and the gross efficiency drops by 2.773 percentage points.
Źródło:
Modern Engineering; 2021, 3; 5--13
2450-5501
Pojawia się w:
Modern Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of life support system (LSS) within modern armoured vehicle
Autorzy:
Hadayo, A.
Schlosberg, S.
Powiązania:
https://bibliotekanauki.pl/articles/244120.pdf
Data publikacji:
2009
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
Life Support System (LSS)
Armoured Fighting Vehicle (AFV)
Microclimate cooling
ndividual Crew Cooling System (ICCS)
NBC protection
Auxiliary Power Unit (APU)
Opis:
Armoured Fighting Vehicle (AFV) personnel are being subjected to high ambient temperatures, humidity and radiant heat loads for hours during deployments in the hot dry desert or warm humid tropical environment. The heat stress is even worst while operating the AFV in Nuclear Biological & Chemical (NBC) Protection mode. Maintaining crew 's physical and cognitive performance amidst all of the stressors of the battlefield is a huge tash. However, if the heat stress imposed by exposure to the climatic extremes of the environment can be controlled with the use of a microclimate cooling system then this allows the soldiers to remain focused on other critical tasks. Life Support System (LSS) is an integrated Microclimate and/or Individual Crew Cooling System (ICCS) integrated with NBC Protection system. The use of LSS or LSS that is complimented by Auxiliary Power Unit (APU) on modern AFVs ensures to the mounted soldiers the ability to maintain safe body temperature. This session will discuss the efficiency of LSS and LSS-APU on AFYs.
Źródło:
Journal of KONES; 2009, 16, 1; 199-202
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies