Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Functioning Efficiency of the Central Air-Conditioning System on the Selected Example

Tytuł:
Functioning Efficiency of the Central Air-Conditioning System on the Selected Example
Autorzy:
Szlązak, Nikodem
Swolkień, Justyna
Powiązania:
https://bibliotekanauki.pl/articles/2064267.pdf
Data publikacji:
2020
Wydawca:
STE GROUP
Tematy:
air conditioning
climate hazard
cooling power
klimatyzacja
zagrożenie klimatyczne
moc chłodzenia
Źródło:
New Trends in Production Engineering; 2020, 3, 1; 41--55
2545-2843
Język:
angielski
Prawa:
CC BY-NC-ND: Creative Commons Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Unported
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
One of the particularly significant threats during exploitation is the climatic threat, which is associated with an increase in the overall costs that are allocated to combating it. The rise in the virgin temperature of the rock mass by 1oC increases the demand for the required cooling capacity to be taken from the air. The publication assesses the effectiveness of the air-conditioning installation by testing its operation on a selected example. The assessment of the efficiency of the air-conditioning installation for a selected hard coal mine showed that none of the five tested coolers achieved the maximum assumed rated power. The use of total power (7.5 MW) in mining excavations was less than 50% and amounted to η = 0.472%. The research showed that the main reason for obtaining low cooling parameters is the inability to locate them in the place of the highest air temperatures. The other problem is an insufficient airflow rate of cooling water supplied to the coolers at too high temperature. The above considerations indicated that the cooling power from built-in air- conditioning systems is not properly and effectively used. Improving the efficiency of its functioning is possible by proceeding research that will eliminate the above factors and by using air conditioning equipment, taking into account the periodic audit of their work to reduce electricity consumption.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies