Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "chlorination" wg kryterium: Temat


Tytuł:
Potassium chloride recovery from mechanically activated microcline through the chlorination roasting and leaching route
Autorzy:
Alyosif, Bahaa
Uysal, Turan
Erdemoğlu, Murat
Powiązania:
https://bibliotekanauki.pl/articles/24148588.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
KCl
K-feldspar
chlorination roasting
mechanical activation
energy efficiency
Opis:
In this study, effects of mechanical activation in the chlorination roasting and water leaching route known as CaCl2 process and developed for the production of potassium chloride (KCl) from potassium feldspar ores were studied. A microcline containing K-feldspar ore with 10.89% K2O was first intensively dry milled by a planetary ball mill and mixed with calcium chloride (CaCl2) and then roasted at temperatures up to 1000 °C to obtain KCl that will be finally dissolved by the water leaching. Potassium recovery by water leaching increased rapidly up to 800 °C. At higher temperatures, the recovery decreased fast due to the evaporation of KCl. According to the K recovery values per unit energy consumed, the optimum roasting temperature was determined as 750 °C and the milling time was 15 min. It was concluded that intensive milling causes mechanical activation of the microcline to reduce the chlorination roasting temperature, which triggers a rise in the K recovery by the water leaching.
Źródło:
Physicochemical Problems of Mineral Processing; 2023, 59, 5; art. no. 167500
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination and evaluation of seasonal changes of DBPs after chlorination in networks using underground water. Muş, Turkey case
Autorzy:
Avşar, Edip
Sönmez, Mücahit
Kiliç, Adile
Powiązania:
https://bibliotekanauki.pl/articles/2171844.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
działanie rakotwórcze
węgiel organiczny
THM
HAN
chlorowanie wody
zmiany sezonowe
carcinogenicity
organic carbon
water chlorination
seasonal changes
Opis:
This study aimed to determine the seasonal change of the concentrations of trihalomethanes (THMs) and one of the newly emerging byproducts haloacetonitriles (HANs), the most abundant group of some disinfection by-products (DBPs) forming as a result of chlorination of drinking water supplied from 2 different reservoirs to the city centre of Muş for disinfection purposes and called chlorinated organic halogens. The quantitative determination of these compounds, some of which may have carcinogenic properties, and the evaluation of their possible effects on public health constitute the importance of the study. The results show that although there is not sufficient chlorination in both water networks and total organic carbon (TOC) values are low in underground water, the total THMs some-times exceed the 100 μg/dm3 value applied in Turkey and pose a risk. It was observed that the total HAN values remain below the 2 μg/dm3 concentration in both networks.
Źródło:
Environment Protection Engineering; 2022, 48, 4; 5--19
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The implementation of a coefficient diagram method based polynomial controller for a non-linear process with a distributed control system in a chlorine scrubber system
Implementacja wielomianowego regulatora opartego na metodzie diagramu współczynników dla procesu nieliniowego z rozproszonym systemem sterowania w systemie płuczki chloru
Autorzy:
Murugan, T. Maris
Shankar, T.R. Kiruba
Powiązania:
https://bibliotekanauki.pl/articles/2173816.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
chlorination scrubber system
PID controller
distributed control system
DCS
coefficient diagram method
CDM
interacting conical tank
system oczyszczania chloru
regulator PID
rozproszony system sterowania
metoda diagramu współczynników
współpracujący zbiornik stożkowy
Opis:
The seawater desalination process is emerging as a substantial source of fresh water by removing salt and minerals from an infinite supply of seawater effectively. The first stage in a desalination plant is the use of chlorine gas to sterilize the microorganisms in the water. During excess chlorine leakage, an alert is activated, employees are relocated away from the site for a specific period, and dampers will be manually opened. This will cause unsafe working conditions and a waste of time. To overcome this problem, this paper proposes a coefficient diagram method based proportional integral derivative (CDM-PID) control strategy for the tune the control parameter with the distributed control system (DCS) interfaced conical tank. During operation, a 10% NaOH solution is injected into the top of the scrubber column using an ethylene-ter-polymer (ETA) designed distributor to ensure that the solution is evenly distributed across the packing surface. The three control strategies are compared to tune the control parameter with the DCS interfaced conical tank. Instead of the sodium hydroxide tank in the chlorine scrubber system, this work presents the pilot plant of DCS interfaced with two conical tank interacting systems with different liquid level heights. Here, the proposed CDM-PID controller is compared with the standard Ziegler-Nichols (ZN)-ultimate cycling method, and the internal model control (IMC) method. The results demonstrated that the proposed CDM-PID approach is superior to existing approaches in terms of low oscillation, settling period, and high robustness.
Proces odsalania wody morskiej staje się znaczącym źródłem świeżej wody dzięki skutecznemu usuwaniu soli i minerałów z nieskończonych zasobów wody morskiej. Pierwszym etapem w zakładzie odsalania jest użycie chloru gazowego do sterylizacji mikroorganizmów w wodzie. Podczas nadmiernego wycieku chloru zostanie aktywowany alarm, pracownicy zostaną na pewien czas przeniesieni z terenu zakładu, a klapy zostaną ręcznie otwarte. Spowoduje to niebezpieczne warunki pracy i stratę czasu. Aby rozwiązać ten problem, w niniejszym artykule zaproponowano strategię sterowania opartą na metodzie wykresu współczynników proporcjonalno-całkująco-różniczkujących (Coefficient Diagram Method-Proportional Integral Derivative – CDM-PID) w celu dostrojenia parametru sterowania za pomocą zbiornika stożkowego połączonego z rozproszonym systemem sterowania (Distributed Control System – DCS). Podczas pracy do góry płuczki wstrzykuje się 10% roztwór NaOH za pomocą dystrybutora zaprojektowanego z etylenu-ter-polimeru (Ethylene-Ter-Polymer – ETA), aby zapewnić równomierne rozprowadzenie roztworu na powierzchni wypełnienia. Trzy strategie sterowania są porównywane w celu dostrojenia parametru kontrolnego za pomocą zbiornika stożkowego połączonego z DCS. Zamiast zbiornika wodorotlenku sodu w systemie płuczki chloru, w niniejszej pracy przedstawiono Instalację Pilotażową DCS połączoną z dwoma współpracującymi ze sobą stożkowymi układami zbiorników o różnych wysokościach poziomu cieczy. Tutaj, proponowany regulator CDM-PID jest porównywany ze standardową metodą Zieglera-Nicholsa (ZN)-Ultimate Cycling oraz metodą kontroli modelu wewnętrznego (Internal Model Control – IMC). Wyniki pokazały, że proponowane podejście CDM-PID przewyższa istniejące podejścia pod względem niskich oscylacji, okresu osiadania i wysokiej odporności.
Źródło:
Gospodarka Surowcami Mineralnymi; 2022, 38, 4; 231--255
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling studies of water chlorination efficiency in municipal water supply network
Analiza modelowa efektywności chlorowania wody w miejskiej sieci wodociągowej
Autorzy:
Musz-Pomorska, Anna
Widomski, Marcin K.
Powiązania:
https://bibliotekanauki.pl/articles/1819557.pdf
Data publikacji:
2020
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
chlorine decay
chlorination of water
chlorine distribution in water
EPANET
rozkład chloru
chlorowanie wody
dystrybucja chloru w wodzie
Opis:
Chlorination of water belongs to the basic methods of its disinfection and is commonly used, permanently or periodically, as the final stage of water treatment in many water treatment stations in Poland. Although, the chlorination process is a well-known phenomenon, the selection of an appropriate dose of disinfectant is still a difficult task. The lack of chlorine in the water or its excessively low content (below 0.2 mg × dm–3) may result in the lack of microbiological protection of water flowing through the pipes. A reverse situation is also unfavourable. The use of too high doses of chlorine at the entrance to the network, on the one hand, ensures adequate disinfectant concentration even in the fittings of the network, on the other hand, it can lead to dangerous for health disinfection by-products (DBPs) including trihalomethanes (THMs). The selection of the proper dose of chlorine should take into account factors affecting its consumption, chemical parameters of water as well as hydraulic parameters of water transport. Such possibilities are available due to application of numerical modelling to study the transport of chlorine in water. The aim of the presented research is to analyse the effectiveness of chlorination of water in a selected water supply network. Simulation tests were carried out for the various doses of disinfectant supplied to the network for the assumed duration of the simulation – 168 hours. The qualitative model was developed in the Epanet 2.0 software using a hydraulic model of the tested network. The first order chlorine decay reaction was assumed to modelling studies, with applied literature values of decay rate of chlorine in water. The results of simulation tests of chlorine transport in the network revealed difficulties in choosing the right dose of chlorine necessary to ensure microbiological protection of water in the network. The forced flow allowed effective disinfection of water.
Źródło:
Ecological Chemistry and Engineering. A; 2020, 27, 1-2; 1-13
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Variant analysis of the chlorination efficiency of water in a selected water supply network
Analiza wariantowa efektywności chlorowania wody w wybranej sieci wodociągowej
Autorzy:
Musz-Pomorska, Anna
Widomski, Marcin K.
Powiązania:
https://bibliotekanauki.pl/articles/127168.pdf
Data publikacji:
2020
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
chlorination of water
chlorine distribution in water
EPANET
modelling of chlorine transport
chlorowanie wody
rozprzestrzenianie chloru w wodzie
modelowanie transportu chloru
Opis:
Chlorination of water belongs to the basic methods of its disinfection and is commonly used, permanently or periodically, as the final stage of water treatment at many water treatment stations in Poland. Although, the chlorination process is a well-known phenomenon, the selection of an appropriate dose of disinfectant is still a difficult task. The lack of chlorine in the water or its too low content (below 0.2 mg · dm–3) results in the lack of microbiological protection of water flowing through the pipes. A reverse situation is also unfavourable. The use of too high doses of chlorine at the entrance to the network, on the one hand, ensures adequate disinfectant concentration even in the fittings of the network, on the other hand, it can lead to dangerous for health disinfection by-products (DBPs) including trihalomethanes (THMs). The selection of the proper dose of chlorine should take into account factors affecting its consumption, chemical parameters of water as well as hydraulic parameters of water transport. Such possibilities are available due to application of numerical modelling to study the transport of chlorine in water. The aim of the presented research is to analyse the effectiveness of chlorination of water in a selected water supply network. Simulation tests were carried out for various doses of disinfectant supplied to the network for the assumed duration of the simulation - 168 h. The qualitative model was developed in the EPANET 2.0 software using a hydraulic model of the tested network. The first order chlorine decay reaction was assumed to modelling studies, with applied literature values of decay rate of chlorine in water. The results of simulation tests of chlorine transport in the network revealed difficulties in choosing the right dose of chlorine necessary to ensure microbiological protection of water in the network. The forced flow allowed effective disinfection of water.
Chlorowanie wody należy do podstawowych metod jej dezynfekcji i jest powszechnie stosowane stale lub okresowo jako końcowy etap uzdatniania wody na wielu stacjach uzdatniania wody w Polsce. Mimo iż sam proces chlorowania jest zjawiskiem dobrze znanym, to dobór odpowiedniej dawki dezynfektanta jest nadal zadaniem sprawiającym trudności. Brak chloru w wodzie bądź jego zbyt mała zawartość (poniżej 0,2 mg·dm–3) skutkuje brakiem ochrony mikrobiologicznej wody przepływającej w przewodach. Niekorzystna jest również sytuacja odwrotna. Stosowanie zbyt dużych dawek chloru na wejściu do sieci z jednej strony zapewnia odpowiednie stężenie dezynfektanta nawet w końcowych odcinkach sieci, z drugiej strony może prowadzić do powstawania niebezpiecznych dla zdrowia ubocznych produktów dezynfekcji, w tym trihalometanów. Dobór odpowiedniej dawki chloru powinien uwzględniać czynniki wpływające na jego zużycie, parametry chemiczne wody, a także parametry hydrauliczne transportu wody. Takie możliwości daje zastosowanie modelowania numerycznego do badania transportu chloru w wodzie. Celem prezentowanych badań jest analiza efektywności chlorowania wody w wybranej sieci wodociągowej. Badania symulacyjne przeprowadzono dla różnych dawek dezynfektanta podawanych do sieci przez założony czas trwania symulacji - 168 godzin. Model jakościowy wykonano w programie EPANET 2,0 przy zastosowaniu modelu hydraulicznego badanej sieci. Do obliczeń symulacyjnych rozkładu chloru przyjęto pierwszorzędową reakcję jego rozkładu oraz literaturowe wartości stałych szybkości jego rozkładu. Wyniki badań symulacyjnych transportu chloru w sieci uwidoczniły trudności w doborze odpowiedniej dawki chloru niezbędnej do zapewnienia ochrony mikrobiologicznej wody w badanej sieci. Dopiero wymuszenie przepływu pozwoliło na efektywną dezynfekcję wody.
Źródło:
Proceedings of ECOpole; 2020, 14, 1; 19-28
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of selected water disinfection technologies with the use of life cycle assessment
Porównawcza analiza wybranych technologii dezynfekcji wody przy wykorzystaniu środowiskowej analizy cyklu życia
Autorzy:
Jachimowski, Artur
Nitkiewicz, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/205450.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
LCA
life cycle assessment
drinking water
sodium hypochlorite
chlorination
water disinfection
UV disinfection
cykl życia
woda pitna
podchloryn sodu
chlorowanie
dezynfekcja wody
dezynfekcja UV
Opis:
The objective of the paper is to use life cycle assessment to compare environmental impact of different technologies used in the process of water disinfection. Two scenarios are developed for water disinfection life cycle at ZUW Raba water treatment plant: (1) historical, in which gaseous chlorine is used as a disinfectant and (2) actual, in which UV radiation and electrolytically generated sodium hypochlorite are used for that purpose. Primary data is supplemented with ecoinvent 3 database records. Environmental impact is assessed by IMPACT2002+ method and its midpoint and endpoint indicators that are calculated with the use of SimaPro 8.4 software. The focus of the assessment is on selected life cycle phases: disinfection process itself and the water distribution process that follows. The assessment uses the data on flows and emissions streams as observed in the Raba plant. As the results of primal analysis show, a change of disinfectant results in quantitative changes in THMs and free chlorine in water supplied to the water supply network. The results of analysis confirm the higher potential of THMs formation and higher environmental impact of the combined method of UV/NaClO disinfection in distribution phase and in whole life cycle, mainly due to the increase of human toxicity factors. However, during the disinfection phase, gaseous chlorine use is more harmful for environment. But the final conclusion states that water quality indicators are not significant in the context of LCA, while both disinfection and distribution phases are concerned.
Celem artykułu było pokazanie wykorzystania środowiskowej oceny cyklu życia (LCA) do porównania wpływu na środowisko różnych technologii stosowanych w procesie dezynfekcji wody. Dla cyklu życia procesu dezynfekcji wody w zakładzie uzdatniania wody Raba Miejskiego Przedsiębiorstwa Wodociągów i Kanalizacji (MPWiK) w Krakowie w niniejszej pracy zostały sformułowane dwa scenariusze: (1) historyczny, w którym dezynfektantem jest chlor gazowy oraz (2) bieżący, w którym tę rolę spełnia układ dwustopniowy z promieniowaniem UV i podchlorynem sodu. Podstawowe dane były uzupełniane rekordami bazy danych ecoinvent 3. Oddziaływanie środowiskowe poddano ocenie przy wykorzystaniu metody IMPACT2002+. Pośrednie i końcowe wskaźniki kategorii wpływu wyliczono przy wykorzystaniu oprogramowania SimPro 8. Analiza obejmowała wybrane fazy cyklu życia: sam proces dezynfekcji i następujący po nim proces dystrybucji wody. W ocenie wykorzystano dane ilościowe o przepływach i emisjach w procesie dezynfekcji wody z wybranego zakładu uzdatniania wody. Wyniki wstępnych analiz pokazują, że zmiana dezynfektanta powoduje zmiany ilościowe trihalometanów (THM) i chloru wolnego w wodzie dostarczanej do sieci wodociągowej. Analiza wskazuje, że w fazie dezynfekcji użycie chloru gazowego jest bardziej szkodliwe dla środowiska. Natomiast wyniki analizy potwierdzają wyższy potencjał tworzenia się THM i większy wpływ na środowisko połączonej metody dezynfekcji UV/NaClO w fazie dystrybucji wody.
Źródło:
Archives of Environmental Protection; 2019, 45, 3; 3-10
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Understanding the Synergic Corrosion Issues with Regard to the Water Treatment Station
Autorzy:
Włodarczyk, Renata
Majek, Klaudiusz
Powiązania:
https://bibliotekanauki.pl/articles/125250.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
chlorination
corrosion microbiology
pitting corrosion
synergy effect
water treatment station
Opis:
The paper presents the examples of damage of elements caused by incorrect assessment of pipeline work conditions. The presented damage cases resulted in the need to replace pipelines. This work is an analysis pertaining to the impact of chemical and microbiological synergy of corrosion on stainless steel pipelines. The paper investigates the corrosion mechanisms that may occur under normal operating conditions at each water treatment station, and the methods of counteracting the corrosion were indicated. The analysis of the corrosion mechanisms was formulated taking into account the design stage, – the correctness of the steel grade choice by the designer, the stage of implementation – the most common implementation errors, and the operational stage – optimization of the technological system work and the effects of the introduced changes. The analysis was carried out at a water treatment plant in Poland with a maximum flow of 20,000 m3 a day-1, which draws raw water from deep water intakes and from a surface intake. The treatment technology includes an aeration system (aeration) and a two-stage treatment process using sand and carbon filters. The disinfection process and prophylaxis in the water treatment plant is based on the use of chlorine gas.
Źródło:
Journal of Ecological Engineering; 2019, 20, 6; 90-96
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identyfikacja ubocznych produktów rozkładu wybranych pestycydów w trakcie zaawansowanych procesów utleniania
Identification of degradation by-products of selected pesticides during advanced oxidation processes
Autorzy:
Kudlek, E.
Powiązania:
https://bibliotekanauki.pl/articles/127037.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
pestycydy
produkty uboczne
ozonowanie
promieniowanie UV
chlorowanie
pesticides
by-products
ozonation
UV irradiation
chlorination
Opis:
W pracy dokonano próby identyfikacji ubocznych produktów rozkładu trzech pestycydów, tj. triklosanu, trialatu i oksadiazonu, w trakcie ozonowania, chlorowania i oddziaływania promieniami UV na ich roztwory wodne. Identyfikację związków wykonano w oparciu o wyniki analizy GC-MS z wykorzystaniem biblioteki widm masowych NIST v17. Wykazano, że w trakcie wszystkich trzech przeprowadzonych procesów dochodzi do niepełnego rozkładu pestycydów. Wraz ze wzrostem dawki ozonu i czasu naświetlania promieniami UV wzrastała liczba generowanych produktów rozkładu związków. W trakcie procesu chlorowania dochodziło do przyłączania się jonów Cl- do cząsteczek badanych mikrozanieczyszczeń, co w przypadku triklosanu prowadziło do generowania związków zawierających w swojej budowie cztery lub pięć atomów chloru. Wykonana analiza toksykologiczna z użyciem testu Microtox® i Lemna sp. Growth Inhibition Test wykazała toksyczny charakter roztworów poprocesowych. Uboczne produkty rozkładu triklosanu i trialatu powstałe w procesie naświetlania ich wodnych roztworów promieniami UV przyjmowały charakter wysokotoksyczny względem organizmów wskaźnikowych (efekt toksyczny >75 %). Uniemożliwia to odprowadzenie tych roztworów do środowiska naturalnego.
The paper presents an attempt of the identification of the decomposition by-products of three pesticides: triclosan, triallat and oxadiazon during ozonation, chlorination and UV irradiation of their water solutions. The identification of compounds was performed based on the results of the GC-MS analysis using the NIST v17 mass spectral library. It has been shown that during all of tested decomposition processes, incomplete degradation of pesticides occurs. The number of micropollutant decomposition by-products increases with the increase of applied ozone dose and UV irradiation time. During the chlorination process Cl– ions were added to the tested compound molecules. In the case of triclosan, it led to the generation of compounds containing four or five chlorine atoms in their structure. The toxicological analysis performed by the use of the Microtox® and Lemna sp. Growth Inhibition Test showed the toxic nature of post-process solutions. The decomposition by-products of triclosan and triallat, generated during the UV irradiation process, were highly toxic against the test organisms (toxic effect > 75%). This makes it impossible to drain these solutions into the natural environment.
Źródło:
Proceedings of ECOpole; 2018, 12, 2; 513-521
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie prekursorów THM z wody powierzchniowej w procesie koagulacji
THM precursors remowal from sufrace water in the coagulation process
Autorzy:
Dąbrowska, L.
Ogrodnik, A.
Powiązania:
https://bibliotekanauki.pl/articles/126048.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
koagulacja
materia organiczna
chlorowanie
trihalometany
woda powierzchniowa
coagulation
organic matter
chlorination
trihalomethanes
surface water
Opis:
Celem badań była ocena efektywności zastosowania procesu koagulacji z wykorzystaniem wstępnie zhydrolizowanego chlorku poliglinu do obniżenia poziomu zanieczyszczenia substancjami organicznymi. Do badań wykorzystano wodę pobraną w kwietniu i czerwcu 2016 roku z rzeki Pilicy w miejscowości Sulejów i z rzeki Warty w Częstochowie. W wodach oczyszczonych w procesie koagulacji uzyskano obniżenie zawartości związków organicznych oznaczonych jako OWO o 41-48%, a oznaczonych jako utlenialność o 44-61%. Zarówno w nieczyszczonych wodach powierzchniowych, jak i w wodach po procesie koagulacji nie stwierdzono obecności trihalometanów (THM), natomiast ich obecność wykazano w tych wodach po procesie chlorowania. W wodach po procesie koagulacji poddanych chlorowaniu stężenie CHCl3 wynosiło od 17,5 do 45,1 μg/dm3, a stężenie CHCl2Br od 4,3 do 10,7 μg/dm3. Były to wartości o 13-43% niższe od uzyskanych stężeń THM w nieoczyszczonych wodach powierzchniowych poddawanych chlorowaniu. Chociaż podczas procesu koagulacji usuwana była znacząca część materii organicznej, jednak pozostała część nadal charakteryzowała się wysokim potencjałem tworzenia THM. Najniższe stężenia THM otrzymano w wodzie pochodzącej z rzeki Warty, chociaż cechowała się wyższą zawartością substancji organicznych.
The aim of this study was to evaluate the effectiveness of the coagulation process using pre-hydrolyzed polyaluminium chloride in reducing the level of pollution of surface water with organic substances. Water collected in April and June 2016, from the Pilica river in Sulejow and the Warta river in Czestochowa was used in the study. In water after the coagulation process, a reduction in the content of organic compounds assayed as TOC by 41-48% was obtained, and assayed as oxygen consumption by 44-61%. In untreated surface water as well as in water after the coagulation process, presence of trihalomethanes THM was not determined. However, their presence was demonstrated in water after the chlorination process. In water after the coagulation process subjected to chlorination, CHCl3 concentration ranged from 17.5 to 45.1 μg/dm3 and the concentration of CHCl2Br ranged from 4.3 to 10.7 μg/dm3. These were values by 13-43% lower than THM concentration obtained in untreated surface water subjected to chlorination. Although during the coagulation process a significant portion of organic matter was removed, yet the remaining part was still characterized by a high THM formation potential. The lowest THM concentration was obtained in water originating from the Warta river, although it was characterized by a higher content of organic substances.
Źródło:
Proceedings of ECOpole; 2016, 10, 2; 617-623
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza kinetyki zmian zawartości utleniacza w wodzie na przykładzie chloru
Kinetics analysis of oxidant content variations in water with chlorine as an example
Autorzy:
Bielski, A.
Zymon, W.
Powiązania:
https://bibliotekanauki.pl/articles/237101.pdf
Data publikacji:
2015
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
chlorowanie
zbiorniki kontaktowe
sieć wodociągowa
chlorination
contact chamber
water supply system
Opis:
Przyjmowane obecnie proste modele kinetyki reakcji redoks, oparte na reakcji jednocząsteczkowej pierwszego lub n-tego rzędu, mogą prowadzić do znacznych błędów. Bardziej zaawansowane modele kinetyczne polegają na rozwiązywaniu układów równań różniczkowych wymagających odpowiedniego oprogramowania umożliwiającego wyznaczenie wielu parametrów. W pracy przeanalizowano możliwość zastosowania modelu dwucząsteczkowego m-tego rzędu względem reduktora i n-tego rzędu względem utleniacza, który wykorzystano do interpretacji wyników badań przebiegu chlorowania wody w warunkach laboratoryjnych. Uzyskano model dobrze opisujący przebieg utleniania zanieczyszczeń wody chlorem. W modelu tym wyznaczono stałą określającą zawartość reduktorów znajdujących się w wodzie w przeliczeniu na równoważną ilość utleniacza. Szybkość rozkładu chloru towarzyszącego procesowi utleniania była porównywalna z szybkością zaniku chloru w wodzie. W związku z tym szybkość rozkładu utleniacza powinna być uwzględniona w równaniu kinetycznym opisującym jego zanik w wodzie. Zaproponowano model kinetyczny w postaci układu dwóch równań opisujących proces utleniania przebiegający według dwucząsteczkowego mechanizmu m-tego i n-tego rzędu, z jednoczesnym uwzględnieniem rozkładu utleniacza przebiegającego zgodnie z mechanizmem jedno-cząsteczkowym pierwszego rzędu. Model tego typu można wykorzystać w projektowaniu układu oczyszczania wody oraz podczas eksploatacji sieci wodociągowej.
Simple models based on unimolecular reactions of the first or n-th order currently used to describe redox kinetics may lead to serious errors. More sophisticated kinetic models require solving differential equation systems, which is only possible with an appropriate software to determine multiple parameters. Here, the authors examined the applicability of a bimolecular model of m-th order to a reducer and n-th order to an oxidant to analyze the laboratory results of water chlorination. The obtained model described well the process of water contaminant oxidation with chlorine. It allowed for determination of a constant defining the reducer content in water, calculated as equivalent of an oxidant. Chlorine decomposition rate, accompanying the oxidation process, was comparable to the rate of chlorine decay from water. Therefore, oxidant decomposition rate should be included in kinetic equation describing oxidant decay rate. Finally, another kinetic model was proposed, represented by a two-equation system describing oxidation based on a bimolecular mechanism of m-th and n-th order, taking into consideration oxidant decomposition according to the first order unimolecular mechanism. A model of this kind could be applied to designing water treatment system and during water supply system operation.
Źródło:
Ochrona Środowiska; 2015, 37, 1; 11-23
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sezonowe zmiany zawartości lotnych halogenowych organicznych ubocznych produktów chlorowania wody w sieci wodociągowej Krakowa
Seasonal variations in volatile organic halogen water chlorination by-product content in Krakow city water distribution system
Autorzy:
Włodyka-Bergier, A.
Bergier, T.
Powiązania:
https://bibliotekanauki.pl/articles/237424.pdf
Data publikacji:
2013
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
system dystrybucji wody
produkty uboczne chlorowania
trójhalometany
halogenoacetonitryle
halogenoketony
chloropikryna
wodzian chloralu
water distribution system
chlorination by-products
trihalomethanes
haloacetonitriles
haloketones
chloropicrin
chloral hydrate
Opis:
W wodzie wodociągowej zbadano zawartość związków z grupy trójhalometanów (trichlorometan, bromodichlorometan, dibromochlorometan i tribromometan), halogenoacetonitryli (bromochloroacetonitryl, dibromoacetonitryl, dichloroacetonitryl i trichloroacetonitryl), halogenoketonów (1,1-dichloro-2-propanon i 1,1,1-trichloro-2-propanon) oraz chloropikryny (trichloronitrometan) i wodzianu chloralu. W latach 2011/2012 pobrano i za-nalizowano próbki wody z dwóch krakowskich systemów dystrybucji wody – Raba” i „Bielany”. Systemy te różnią się jakością ujmowanej wody oraz układem jej oczyszczania, a także wielkością sieci dystrybucji. W obu zakładach stosuje się dezynfekcję wody chlorem. Analiza otrzymanych wyników pozwoliła ocenić sezonowe (wiosna, lato, jesień, zima) zmiany w ilości poszczególnych grup lotnych produktów ubocznych chlorowania w wodzie z obu systemów. Przeprowadzone badania wykazały istotny wpływ zmian temperatury wody (związanych z porą roku), a więc ilości i rodzaju prekursorów obecnych w chlorowanej wodzie, na zawartość lotnych produktów ubocznych dezynfekcji powstających w sieci wodociągowej.
Content of the following compounds in water has been examined: trihalomethanes (trichloromethane, bromodichloromethane, dibromochloromethane, tribromomethane), haloacetonitriles (bromochloroacetonitrile, dibromoacetonitrile, dichloroacetonitrile, trichloroacetonitrile), haloketones (1,1-dichloro-2-propanone, 1,1,1-trichloro-2-propanone), chloropicrin and chloral hydrate. In the period of 2011–2012 samples from terminal ends of the two water distribution systems in Krakow: ‘Raba’ and ‘Bielany’ were collected and analyzed. These systems differ in raw water quality, treatment train arrangement as well as distribution network size. Chlorination to disinfect the water is applied in both plants. The result analysis allowed assessment of seasonal variations (spring, summer, autumn, winter) in individual volatile chlorination by-product group content for each of the considered water distribution systems. Research conducted demonstrated significant influence of season-related water temperature fluctuations, therefore of the amount and type of precursors present in chlorinated water, on volatile halogen disinfection by-product content formed in the water distribution system.
Źródło:
Ochrona Środowiska; 2013, 35, 4; 23-27
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zmian ilości ubocznych produktów chlorowania i ozonowania w wodzie wodociągowej w Białymstoku
Analyzing the changes in the quantity of ozonation and chlorination by-products in the tap water for the city of Bialystok
Autorzy:
Kucharski, M.
Powiązania:
https://bibliotekanauki.pl/articles/237379.pdf
Data publikacji:
2011
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
chlorowanie
ozonowanie
uboczne produkty utleniania
trójhalometany
kwasy halogenooctowe
bromki
bromiany
chlorination
ozonation
oxidation by-products
trihalomethanes
haloacetic acids
bromide
bromate
Opis:
Przedstawiono wyniki wieloletnich badań zawartości trójhalometanów (THM), kwasów halogenooctowych (HAA) i bromianów (BrO3-) w wodzie wodociągowej w Białymstoku. Wykazano, że w czasie gdy stosowano wstępne chlorowanie zawartość chloroformu w wodzie była bardzo duża (155÷194 mg/m3), maks. 240 mg/m3 w 1995 r. W 1998 r., po zmianie wstępnego chlorowania na ozonowanie, zawartość chloroformu wynosiła 12,2÷90,4 mg/m3 (średnio 36,6 mg/m3), a suma trójhalometanów (TTHM) wynosiła 13,8÷96,7 mg/m3. W kolejnych latach ilość chloroformu systematycznie malała z ponad 200 mg/m3 (1995-1996), poprzez 65 mg/m3 (2006) aż do poniżej 20 mg/m3 (2009-2010). Jednocześnie suma kwasów halogenooctowych (THAA) zmalała z 8,4÷126,6 mg/m3 (2004-2006) do 4,4÷13,4 mg/m3 (2009-2010). Zawartość bromianów po wprowadzeniu ozonowania nigdy nie przekroczyła dopuszczalnej ilości 10 mgBrO3-/m3, a najczęściej była poniżej 5 mgBrO3-/m3, przy ilości bromków w ujmowanej wodzie 10,4÷23,0 gBr-/m3. Przeprowadzona analiza zmian jakości wody wodociągowej wykazała, że modernizacja zakładu oczyszczania wody spowodowała systematyczną poprawę jej jakości w odniesieniu do zawartości niebezpiecznych dla zdrowia produktów utleniania, takich jak THM, HAA i bromiany.
The paper summarizes the results of many years' investigations into the occurrence of trihalomethanes (THM), haloacetic acids (HAA) and bromates (BrO3-) in the municipal water of Bialystok. Analysis of the data ob-tained has produced the following findings. Over the period when use was made of pre-chlorination, the chloroform content of the water was very high (155 to 194 mg/m3), with a maximal value of 240 mg/m3 in 1995. In 1998, when pre-chlorination was replaced with pre-ozonation, chloroform content varied from 12.2 mg/m3 to 90.4 mg/m3 (36.6 mg/m3 on average), and the sum of trihalomethanes (TTHM) from 13.8 to 96.7 mg/m3. In subsequent years the quantity of chloroform decreased continuingly from 200 g/m3 (1995-1996), through 65 mg/m3 (2006), to a level lower than 20 mg/m3 (2009-2010). Over this period, the sum of haloacetic acids (THAA) fell from 8.4-126.6 g/m3 (2004-2006) to 4.4-13.4 mg/m3 (2009-2010). Upon introduction of the ozonation process, bromate content did not exceed the admissible value of 10 mgBrO3-/m3, and in most instances its concentration in the tap water was lower than 5 mgBrO3-/m3, the quantity of bromides in raw water ranging between 10.4 and 23.0 gBr-/m3. Analysis of the changes in the quantity of ozonation and chlorination by-products makes it clear that the modernization of the water treatment plant has noticeably improved tap water quality primarily with respect to the content of substances carrying serious health implications - THMs, HAAs and bromates.
Źródło:
Ochrona Środowiska; 2011, 33, 3; 47-51
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka prekursorów lotnych ubocznych produktów chlorowania wody w sieci wodociągowej Krakowa
Characterization of precursors to volatile water chlorination by-products in the Krakow water distribution system
Autorzy:
Włodyka-Bergier, A.
Bergier, T.
Powiązania:
https://bibliotekanauki.pl/articles/237365.pdf
Data publikacji:
2011
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
uboczne produkty chlorowania
naturalne substancje organiczne
frakcjonowanie
chlorination by-products
natural organic matter
fractionation
Opis:
Przedstawiono wyniki badań nad wpływem jakości substancji organicznych obecnych w ujmowanych wodach na potencjał tworzenia ubocznych produktów chlorowania. Przeanalizowano zawartość związków z grupy trójhalometanów (trichlorometan, bromodichlorometan, dibromochlorometan, tribromometan), halogenoacetonitryli (trichloroacetonitryl, dichloroacetonitryl, bromochloroacetonitryl, dibromoacetonitryl), halogenoketonów (1,1-dichloropropanon, 1,1,1-trichloropropanon), a także wodzianu chloralu oraz chloropikryny. Do badań wykorzystano próbki wody oczyszczonej (przed dezynfekcją chlorem) pobrane z zakładów oczyszczania wody "Raba" i "Bielany" zaopatrujących Kraków w wodę wodociągową. Substancje organiczne obecne w wodzie zostały rozdzielone na sześć frakcji na złożach jonitowych (DAX-8, AG-MP-50 i WA-10). Otrzymane w wyniku rozdziału kwasy hydrofobowe i hydrofilowe, zasady hydrofobowe i hydrofilowe, a także obojętne frakcje hydrofobowe i hydrofilowe chlorowano w wodzie podchlorynem sodu w czasie 24 h. Następnie za pomocą chromatografii gazowej oznaczono powstałe uboczne produkty chlorowania. Analiza otrzymanych wyników pozwoliła wytypować frakcje, które charakteryzowały się największym powinowactwem do powstawania poszczególnych grup organicznych produktów ubocznych chlorowania wody.
The main focus of the study is the influence of the organic matter quality on the potential of chlorination by-products formation. Water samples were analyzed for the content of trihalomethanes (trichloromethane, bromodichloromethane, dibromochloromethane, tribromomethane), halogenoacetonitriles (trichloroacetonitrile, dichloroacetonitrile, bromochloroacetonitrile, dibromoacetonitrile), halogenoketones (1,1-dichloropropanone, 1,1,1-trichloropropanone), chloral hydrate and chloropicrin. The experiments were conducted with treated water samples (collected before disinfection with chlorine) from the water treatment plants Raba and Bielany, which provide the city of Krakow with municipal water. The organic substances present in the water were made subject to fractionation on ion-exchange resins (DAX-8, AG-MP-50 and WA-10). The products obtained from fractionation, i.e. hydrophobic and hydrophilic acids, hydrophobic and hydrophilic bases, and hydrophobic and hydrophilic neutral fractions, were chlorinated in water with sodium hypochlorite for 24 h. Chlorination by-products were analyzed by gas chromatography. Based on the analysis of the results obtained, the fractions characterized by the highest affinity for the formation of particular groups of volatile organic water chlorination by-products were determined.
Źródło:
Ochrona Środowiska; 2011, 33, 3; 29-33
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technological aspects of the synthesis of 2,4-dichlorophenol
Autorzy:
Białek, A.
Moszczyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/779182.pdf
Data publikacji:
2009
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
2,4-dichlorofenol
chlorowanie
katalizator
dioksyny
kwas 2,4-dichlorofenoksyoctowy
2,4-dichlorophenol
chlorination
catalyst
dioxine
2,4-dichlorophenoxyacetic acid
Opis:
The main factors influencing the selectivity of chlorophenols synthesis were described. The loss of raw materials and the composition of wastes obtained in a conventional technology of 2,4-D production based on 2,4-dichlorophenol (2,4-DCP) of the 89% purity were presented. The influence of some homogenous catalysts on the selectivity of 2,4-dichlorophenol obtained in phenol and chlorine reaction was examined. Using the combined catalyst enables to chlorinate selectively the monochlorophenols to 2,4-DCP without an undesirable increasing of the 2,6-dichlorophenol and 2,4,6-trichlorophenol contents. The catalyst transformations during the reaction of phenol chlorination were investigated and the method of its elimination after the reaction was elaborated.
Źródło:
Polish Journal of Chemical Technology; 2009, 11, 2; 21-30
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szacowanie zmian jakości wody w systemie dystrybucji na podstawie analizy powstawania trihalometanów
Assessing spatial variations of water quality in the water-pipe network by analysis of THM formation
Autorzy:
Zimoch, I.
Powiązania:
https://bibliotekanauki.pl/articles/237782.pdf
Data publikacji:
2007
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
system dystrybucji wody
chlorowanie
jakość wody
trihalometany
trihalomethanes
water distribution system
chlorination
water quality
Opis:
Podczas transportu wody wodociągowej na duże odległości poważnym problemem staje się dostarczenie do odbiorcy wody czystej bakteriologicznie. Pociąga to za sobą konieczność wyboru takiej metody dezynfekcji, która zapewni zgodną z wymaganiami jakość wody przeznaczonej do spożycia. Stosowanie związków chloru do dezynfekcji wody prowadzi do powstawania halogenowych związków organicznych, w tym trihalometanów (THM). Zwiększenie zawartości THM w wodzie w sieci wynika nie tylko z konieczności stosowania dużych dawek chloru w procesie dezynfekcji wody, ale również z długiego czasu jej przepływu w systemie wodociągowym. Przedstawiono analizę procesu powstawania THM w sieci wodociągowej Krakowa. W oparciu o uzyskane wyniki badań podjęto próbę opracowania modelu szacowania wtórnego zanieczyszczenia wody powstającymi THM, w zależności od warunków eksploatacji systemu zaopatrzenia w wodę. W analizie uwzględniono zarówno warunki eksploatacyjne układu technologicznego oczyszczania wody, jak i niestabilne warunki funkcjonowania sieci.
When tap water is transported over a long distance, the supplier will have to face the problem of its bacteriological safety. This necessitates a careful choice of the disinfection method in order to provide the user with water of the quality desired. The use of chlorine compounds for water disinfection favours the formation of organic halo-complexes, including trihalomethanes (THM). The increase in the THM content during transport in the water-pipe network is attributable not only to the need of applying high chlorine doses for the purpose of disinfection but also to the long time of water residence in the supply system. The paper presents an analysis of the process of THM formation in the water-pipe network of the city of Cracow. Making use of the results obtained, a model was constructed for the assessment of water recontamination due to the THM being formed, taking into account the service conditions of the water supply system. In the analysis, consideration was given not only to the operating conditions of the treatment train but also to the unstable conditions that characterize the functioning of the water-pipe network.
Źródło:
Ochrona Środowiska; 2007, R. 29, nr 4, 4; 49-52
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies