Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "camera calibration" wg kryterium: Temat


Tytuł:
Space orientation based on image from a mobile camera
Autorzy:
Furtak, J.
Powiązania:
https://bibliotekanauki.pl/articles/273331.pdf
Data publikacji:
2001
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
space orientation
camera calibration
Opis:
This paper presents the pose parameters estimation algorithm for a mobile camera in each of its position. The algorithm is based on recursive filtration of intermediary results. This feature makes a knowledge accumulation during calibration process possible. The algorithm was verified experimentally. The way of an experiment execution method and received results are described.
Źródło:
Biuletyn Instytutu Automatyki i Robotyki; 2001, R. 7, nr 15, 15; 3-14
1427-3578
Pojawia się w:
Biuletyn Instytutu Automatyki i Robotyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Poprawa kontrastu termicznego na potrzeby kalibracji kamer dla termicznej stereowizji
Thermal contrast enhancement in thermal stereo camera calibration
Autorzy:
Moderhak, M.
Powiązania:
https://bibliotekanauki.pl/articles/157645.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stereoskopia
kalibracja kamer
IR thermal stereo
camera calibration
Opis:
Praca przybliża sposób na poprawę kontrastu oraz dokładności kalibracji kamer na potrzeby termicznej stereoskopii. Stereoskopia termiczna oraz synteza trójwymiarowych termogramów nadal napotykają problemy techniczne, które w przypadku zwykłej stereoskopii zostały rozwiązane. Jednym z tych problemów jest dokładna kalibracja układu kamer. Omówiono prosty sposób na poprawę kontrastu w trakcie rejestracji sekwencji obrazów wzorca kalibracyjnego. Pozwala to na dokładniejszą kalibrację systemu 3D złożonego z pary kamer termicznych.
This paper describes a method of thermal contrast enhancement in 3D thermal stereo calibration. Thermal stereoscopy still encounters technical problems that have already been solved in visual stereo-scopy. One of them is the accuracy of camera set calibration data which is one of the most important in the whole process of 3D image synthesis. There are many solutions to this problem but none of them is efficient nor easy to perform. Many of them due to the poor thermal image contrast are inaccurate. There is proposed slight modification of RGB camera calibration procedure which allows calibrating IR cameras using common software (CalibrationToolbox for Matlab) and typical calibration patterns (checker board grid) with increased thermal contrast. A short introduction to the stereo calibration procedure is given in the paper. The calibration pattern is described and quantitative and qualitative comparison between the optical and thermal calibration is performed. The method of contrast enhancement and the analysis of thermal calibration results are presented. This method applied to thermal stereo pair calibration seems to provide better calibration accuracy and makes the procedure invulnerable to ambient IR radiation which can cause reflections disturbing the process.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 11, 11; 935-937
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A stereovision system for three-dimensional measurements of machines
Autorzy:
Grudziński, Marek
Marchewka, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/135398.pdf
Data publikacji:
2019
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
stereovision system
machine vision
camera tracking
camera calibration
calibration pattern
3D reconstruction
Opis:
The modern manufacturing or transportation machines that are used in industrial processes require continuous supervision in certain circumstances and even manual control by a human. Despite the fact the machines are more and more reliable and accurate than they used to be there is still the need for manual and time-consuming programming and safety control, especially when the external conditions change. For the operation of large machines, where the risk of damage and even disaster exists, an additional supervisory system based on vision devices could be utilized. The vision systems are commonly used in a range of simple 2D detection as well as very precise 3D reconstruction. The stereovision systems could be applied for unusual operations, especially in terms of safety and collision avoidance, such as crane observations while transporting a heavy load, robot and CNC machine preparation and normal operation. Through the use of optical devices the observed objects could be quickly positioned. In this research a test bench for stereovision reconstruction for the example of a robotic arm has been presented. The calibration procedures have been explained and accuracy tests in a large measuring volume were performed. Finally the possibilities of the applications and the utilization of such a system have been assessed.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2019, 58 (130); 16-23
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Software application for calibration of stereoscopic camera setups
Autorzy:
Rzeszotarski, D.
Pełczyński, P.
Powiązania:
https://bibliotekanauki.pl/articles/221121.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
camera calibration
canonical stereovision system
intrinsic and extrinsic parameters
Opis:
The article describes an application for calibration of a stereovision camera setup constructed for the needs of an electronic travel aid for the blind. The application can be used to calibrate any stereovision system consisting of two DirectShow compatible cameras using a reference checkerboard of known dimensions. A method forexperimental verification of the correctness of the calibration is also presented. The developed software is intended for calibration of mobile stereovision systems that focus mainly on obstacle detection.
Źródło:
Metrology and Measurement Systems; 2012, 19, 4; 805-816
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metrological Analysis Of Microsoft Kinect In The Context Of Object Localization
Autorzy:
Skalski, A.
Machura, B.
Powiązania:
https://bibliotekanauki.pl/articles/221384.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Kinect motion sensor
localization
camera calibration
measurement precision
robustness
Opis:
This paper presents a comprehensive metrological analysis of the Microsoft Kinect motion sensor performed using a proprietary flat marker. The designed marker was used to estimate its position in the external coordinate system associated with the sensor. The study includes calibration of the RGB and IR cameras, parameter identification and image registration. The metrological analysis is based on the data corrected for sensor optical distortions. From the metrological point of view, localization errors are related to the distance of an object from the sensor. Therefore, the rotation angles were determined and an accuracy assessment of the depth maps was performed. The analysis was carried out for the distances from the marker in the range of 0.8-1.65 m. The maximum average error was equal to 23 mm for the distance of 1.6 m.
Źródło:
Metrology and Measurement Systems; 2015, 22, 4; 469-478
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of the results of aerial photography experiments on the basis of a developed UAV model
Autorzy:
Hlotov, V.
Siejka, Z.
Kolеsnichenko, V.
Prokhorchuk, O.
Tserklevych, A.
Babiy, L.
Powiązania:
https://bibliotekanauki.pl/articles/61628.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
aerial photography
experiment
unmanned aerial vehicle
image mosaicking
digital camera
camera calibration
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2015, IV/3
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensory wizyjne stosowane w systemach do pomiaru skrajni kolejowej i analiza metod ich doboru
Vision sensors in railway clearance measurement systems and analysis of their selection methods
Autorzy:
Tokarczyk, R.
Kohut, P.
Kolecki, J.
Powiązania:
https://bibliotekanauki.pl/articles/130507.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
skrajnia kolejowa
kamera cyfrowa
kalibracja kamery
radiometria kamery
railway clearance
digital camera
camera calibration
radiometric calibration
Opis:
Cechy charakterystyczne systemów wizyjnych stosowanych dla potrzeb pomiaru skrajni można podzielić na trzy grupy: opisujące geometrię odwzorowania, radiometrię i specyfikację techniczną kamery. Geometrię odwzorowania wyznacza się w procesie kalibracji kamery, która dostarcza takich parametrów jak położenie środka rzutów w stosunku do układu obrazu oraz współczynniki funkcji aproksymującej błędy obiektywu i nośnika obrazu. Badanie radiometrii zwykle obejmuje wyznaczenie rozdzielczości układu obiektyw-nośnik obrazu, ostrości i kontrastu (funkcja MTF lub SFR, gamma), zakresu tonalnego, szumu, odwzorowania kolorów. Pozyskiwanie obrazów charakteryzują takie czynniki jak częstotliwość akwizycji oraz przepustowość. Porównane zostaną różne przewodowe i bezprzewodowe technologie interfejsów współczesnych kamer, m.in.: GiGE, CameraLink, USB, FireWire, (decydujące o przepustowości, topologii, wymaganiach co do długości kabli, obciążeniu procesora, czy dopuszczalnej ilość urządzeń akwizycji, itp.). W ramach prowadzonych badań przetestowano kilka reprezentatywnych dla zagadnienia pomiarowego kamer cyfrowych o różnych technologiach interfejsów i wyposażonych w różne obiektywy. W artykule zaprezentowano wyniki kalibracji i testów radiometrycznych wybranych modeli kamer. Wielowariantowa kalibracja geometryczna pozwoliła na zbadanie postawionych problemów: − jaki jest poziom błędów obrazowania przy zastosowaniu różnych obiektywów, − czy można w procesie redukcji błędów obiektywu uwzględniać tylko dystorsję radialną i do ilu czynników wielomianu tej dystorsji wystarczy się ograniczyć, − jakie są błędy szczątkowe obrazu po usunięciu ich optymalnym wielomianem aproksymującym. Badanie radiometrii zdjęć przeprowadzono z użyciem testu IT8, SFR Plus i oprogramowania firmy Imatest. Skupiono się przede wszystkim na najistotniejszych dla obrazowania na potrzeby pomiaru skrajni cechach: ostrości i kontraście, zakresie tonalnym i odwzorowaniu barw. W wyniku badań określono zestaw cech istotnych dla optymalnego wyboru systemu wizyjnego.
The characteristics of imagine systems used in railway clearance measurements can be divided into three groups: geometry of projection, radiometric quality and technical specifications. The geometry of image acquisition is determined in the camera calibration procedure. The interior orientation parameters of camera and distortion model parameters of a lens as well as an imaging sensor are estimated using special test-fields. The radiometric calibration and testing often involves the determination of the imaging system resolution, sharpness and contrast characteristics (MTF or SFR functions and gamma), dynamic range, noise and color projection accuracy. The process of image acquisition can be characterized by frequency and baud rate. The subsequent, widely used wire and wireless communication interfaces of currently used cameras are going to be compared: GiGE, CameraLink, USB, FireWire. The short deprecation of influence of applied interface on the baud rate, systems topology, wire lengths, processor load and the maximum number of connected imagine devices will be given. Within the conducted researches the few appropriate for the railway measurements cameras were tested. The examined cameras have various communication interfaces and were used with various lenses. The results of geometric calibration and radiometric testing will be given. The multi-variant camera calibration allowed to address the following problems: − what we can say about the quantitative characteristics of imagine errors depending on the lens used, − is the modeling of the radial distortion only sufficient and how many coefficients should be applied, − how big are the remaining residuals after applying the systematic image error corrections. The radiometric investigations was conducted using the IT8 and SFR Plus tests. The Imatest software was used. The most important features for the railway clearance measurements were examined, i.e. sharpness, contrast, dynamic range and color projection quality. As a result of conducted researches the set of important for the choice of imaging system features was determined.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2012, 23; 429-440
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kalibracja systemów stereowizyjnych przy użyciu odpornej metody podwójnej płaszczyzny
Robust double-plane calibration of stereovision systems
Autorzy:
Rotter, P.
Byrski, W.
Dajda, M.
Powiązania:
https://bibliotekanauki.pl/articles/274599.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
stereowizja
kalibracja kamer
metoda podwójnej płaszczyzny
stereovision
camera calibration
double-plane method
Opis:
W metodzie podwójnej płaszczyzny (ang. double plane) zależność między współrzędnymi obrazowymi a współrzędnymi w przestrzeni trójwymiarowej jest obliczana na podstawie czterech przekształceń płaszczyzny na płaszczyznę (dwie kamery i dwie płaszczyzny kalibracyjne). Metoda jest intuicyjna i łatwa w implementacji, lecz ma poważną wadę w postaci złego uwarunkowania zadania dla pewnych obszarów przestrzeni. W artykule proponujemy odporną metodę kalibracji, która wykorzystuje dodatkowo trzecią płaszczyznę kalibracyjną. Jest to płaszczyzna wirtualna, która nie jest fizycznie elementem wzorca, ale jest zdefiniowana przez odpowiednio rozmieszczone punkty kalibracyjne na dwóch płaszczyznach podstawowych. Proponowany algorytm wykorzystuje liniową kombinację trzech par płaszczyzn: dla par płaszczyzn, które mogą generować błędy numeryczne przypisywana jest niska waga, minimalizująca ich wpływ na wynik końcowy. Eksperymenty wykazały dużą dokładność i wiarygodność proponowanej metody w stosunku do podstawowej wersji algorytmu: błąd średniokwadratowy i błąd maksymalny zostały zredukowane odpowiednio 4- i 20-krotnie.
In double-plane method for stereovision system calibration the correspondence between screen coordinates and location in 3D space is calculated based on four plane-to-plane transformations: there are two planes of the calibration pattern and two cameras. The method is intuitive and easy to implement but the main disadvantage is ill-conditioning for some spatial locations. In this paper we proposed a robust method which exploits the third plane which physically does not belong to the calibration pattern but can be calculated from the set of reference points. Our algorithm uses combination of three calibration planes with weights which depend on screen coordinates of the point of interest: a pair of planes which could cause numerical errors receives small weight and has practically no inl uence on the i nal results. We analysed errors and their distribution in 3D space for basic and improved algorithm. Experiments demonstrate high accuracy and reliability of our method comparing to the basic version: mean square error and maximum error are reduced 4 times and 20 times respectively.
Źródło:
Pomiary Automatyka Robotyka; 2011, 15, 12; 121-126
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calibration low-cost cameras with wide-angle lenses for measurements
Autorzy:
Wierzbicki, D.
Powiązania:
https://bibliotekanauki.pl/articles/384304.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
sensors
measurements
camera calibration
videos
accuracy
czujnik
pomiary
kalibracja kamery
filmy video
precyzja
Opis:
So far too many examinations concerning the possibility of the application action cameras weren’t conducted in UAV photogrammetric studies. However in the recent time development of the action cameras production technology he let receive sensors which are light, userfriendly, and most importantly can gain images and video sequences of high resolution. The essential meaning has taking into account the camera’s influencing factors in UAV photogrammetry. Due to the fact that the action cameras are non-metric cameras the significant influence on the quality of photogrammetric studies has a stability internal orientation of elements of such cameras. Within the framework of carried out research calibration of five GoPro Hero 4 Black. The calibration of cameras was carried out on different calibration tests in the GML Camera Calibration Toolbox and Agisoft Lens software. Different calibration setups and processing are presented and discussed in this article. Additionally a repetitiveness of achieved results of the calibration was examined in five GoPro cameras Hero 4 Black. Dedicated calibration templates in the form of chessboards were used to the calibration. As a part of the research a comparative analysis of the results have been done. Based on performed examinations a repetitiveness of determined internal orientation elements was checked under different video acquisition modes.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2018, 12, 2; 45-51
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Systemy do pomiaru skrajni kolejowej - przegląd i tendencje rozwojowe
Railway clearance measurement systems - review and development trends
Autorzy:
Mikrut, S.
Pyka, K.
Tokarczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/130974.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
skrajnia kolejowa
kamera cyfrowa
kalibracja kamery
skaner laserowy
railway clearances
digital camera
camera calibration
laser scanning
Opis:
Pomiar skrajni budowli linii kolejowej jest zagadnieniem bardzo praktycznym, realizowanym na całym świecie przy pomocy różnych systemów pomiarowych. Pomiar ten ma na celu głównie określenie granic przestrzeni, jakich nie może przekroczyć żaden obiekt (np. budynek), znajdujący się przy torze. W niniejszym artykule dokonano przeglądu wybranych, istniejących systemów pomiarowych służących do określenia skrajni budowli. Aktualnie pracujące systemy oparte są głównie na trzech grupach metod: fotogrametrycznej – wykorzystującej parę zdjęć, metodzie profili świetlnych zadawanych światłem lasera i rejestrowanych przez szybką kamerę cyfrową oraz metodzie bazującej na pomiarze dalmierzem laserowym lub skanerem laserowym. W systemach najbardziej zaawansowanych łączy się powyższe metody pomiarowe. W opracowaniu wykazano wady i zalety poszczególnych systemów oraz dokonano podsumowania technologicznego wykorzystanych urządzeń pomiarowych. Jak wynika z przeprowadzonych badań literaturowych, aktualnie w przypadku systemów dedykowanych diagnostyce skrajni dominują najczęściej rozwiązania oparte na skanerach laserowych, pozyskujących dane w postaci profili rejestrowanych prostopadle do kierunku jazdy, wsparte ewentualnie systemami wizyjnymi. Natomiast w przypadku uniwersalnych mobilnych systemów widać wyraźną dominację wspólnych konfiguracji skanerów laserowych I kamer cyfrowych wspartych rejestracją INS/GNNS. W tych systemach pomiar obiektów jest odniesiony do globalnego układu współrzędnych, a następnie, po detekcji główek szyn, odbywa się transformacja do układu osi toru. Wstępna analiza prowadzi do wniosku, że dokładność pomiaru skrajni jest wyższa dla systemów specjalistycznych niż dla uniwersalnych.
Measuring of railway structure clearances is a very practical issue, and the operation itself is performed all over the world using various measuring systems. The measurement is aimed chiefly at determining the limits of space that no structure (e.g. a building) located close to the railway track may cross. This paper provides a review of measurement systems used to determine clearance limits of railway buildings. Systems currently in use are based mainly on three groups of measuring methods: the photogrammetric method, which employs a pair of images, the method of light profiles, which are applied by the laser light and recorded by means of a high-speed digital camera, and the method based on laser radar or laser scanner (lidar) measurements. Those most advanced systems combine the above-referenced measurement methods. The paper demonstrates flaws and advantages of particular systems and provides a technological summary of measuring equipment utilized in them. It results from literature queries performed that presently, in the case of systems dedicated to railway clearance diagnostics, these are solutions based on laser scanners, which dominate most often, and which acquire data in the form of crosswise profiles that are recorded perpendicularly to the direction of travel, supported possibly by vision systems. On the other hand, in the case of universal mobile systems, one can notice a distinct domination of joint configurations of laser scanners and digital cameras, supported by INS/GNNS recording. In those systems the measurement of structures is referred to the global system of co-ordinates, and later, upon the detection of rail heads, a transformation to the rail axis arrangement takes place. The preliminary analysis leads to a conclusion that the accuracy of rail clearance measurement is higher in the case of specialised systems as compared to universal ones.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2012, 23; 291-300
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis on the dynamic deformations of the images from digital film sequences
Badania zniekształceń dynamicznych obrazów pochodzących z cyfrowych sekwencji filmowych
Autorzy:
Markowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/145385.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
image sequences
digital video camera
internal geometry
non-metric camera
camera calibration
sekwencje obrazów
kamera cyfrowa
kalibracja kamery
Opis:
Image sequences, in particular digital video sequences, are characterised by the features which result in their high potential as measurement data. However, as early as at the stage of visual assessment of digital film images, originating, in particular, from amateur cameras, occurrence of some deformations may be observed, which may highly influence the results of measurements performed using these images; such deformations differ from deformations occurred in the case of static photographic images. It results both, by the method of image recording, using an electronic shutter and interlaced or progressive scanning, as well as the method of file recording and compression. It is worth to notice the systematic nature of such deformations, which highly depend on mutual motions of a camera and recorded objects. The objective of presented research works was to develop the mathematical description of image deformations, as a function of motion parameters. This would allow for adaptation of the camera calibration process to the demands of sequential imaging, as well as for modification of algorithms of measurements using self-calibration, and, as a result, minimisation of deformations. Another objective was to analyse the influence of deformations, typical for digital film images, on the results of measurements performed using these images, by means of series of experiments, which were based on multiple calibration of static and a moving camera, also with the use of a spatial test field. The first part was made by developing formulas based on some geometric relations, using some simplifications. On the stage of experimental research a certain degree of compatibility of experimental results and theoretical assumptions were confirmed.
Zobrazowania sekwencyjne, a w szczególności sekwencje filmowe, posiadają cechy, dzięki którym mogą mieć duży potencjał pomiarowy. Należą do nich między innymi systematyka i stosunkowo duża częstotliwość obrazowania, skutkujące dużą liczbą obserwacji oraz podobieństwem sąsiednich obrazów (co ma znaczenie przy automatyzacji pomiarów), a ponadto zmniejszony wkład pracy operatora kamery, możliwość pozyskiwania i przetwarzania w czasie rzeczywistym oraz ogromna i nadal zwiększająca się dostępność zobrazowań. Jednak już na etapie oceny wzrokowej cyfrowych zobrazowań filmowych, zwłaszcza pochodzących z kamer określanych powszechnie jako amatorskie, zauważyć można występowanie pewnych zniekształceń, które mogą mieć znaczący wpływ na wyniki pomiarów. Jest to spowodowane zarówno sposobem rejestracji, z wykorzystaniem migawki elektronicznej i przeplotowego lub progresywnego skanowania, jak i metodami zapisu i kompresji plików. Warto zauważyć, iż są to w dużym stopniu deformacje systematyczne, uzależnione od wzajemnego ruchu kamery i badanego obiektu. Celem opisanych w artykule badań była próba opisu, typowych dla cyfrowych zobrazowań filmowych, zniekształceń dynamicznych, w funkcji parametrów ruchu kamery względem obiektu, jak również próba zbadania rozkładu deformacji poprzez wykonane w odpowiedni sposób wielokrotne kalibracje kamery, w celu porównania otrzymanych wartości z rozważaniami teoretycznymi. Pierwsza część została wykonana, poprzez wyprowadzenie w oparciu o relacje geometryczne, wzorów, opisujących deformacje dynamiczne obrazu, w funkcji współrzędnych tłowych, prędkości liniowej lub kątowej, czasu rejestracji pojedynczej linii obrazu oraz odległości obrazowej i odległości kamery od obiektu. Część druga, eksperymentalna, obejmowała z kolei analizy rozkładu zniekształceń dynamicznych dla kilku przykładowych sekwencji, zarejestrowanych w trakcie obrotów kamery wokół poszczególnych osi układu współrzędnych. Analizując wyniki eksperymentów, potwierdzono pewną zgodność występujących rzeczywistych zniekształceń z przewidywaniami, które pojawiły się na etapie rozważań teoretycznych. Niestety nie udało się przeprowadzić konkretnych analiz liczbowych, ponieważ na tym etapie nie opracowano jeszcze metody wyznaczenia czasu rejestracji pojedynczej linii obrazu, co uniemożliwiło oszacowanie wartości teoretycznych deformacji.
Źródło:
Geodesy and Cartography; 2015, 64, 1; 43-64
2080-6736
2300-2581
Pojawia się w:
Geodesy and Cartography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mobile system for the estimation of internal parameters of distributed cameras
Mobilny system estymacji wewnętrznych parametrów kamer rozproszonych
Autorzy:
Mazurek, P.
Powiązania:
https://bibliotekanauki.pl/articles/152936.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
kalibracja kamer
rozproszone systemy akwizycji
systemy zagnieżdżone
camera calibration
distributed acquisition systems
embedded systems
Opis:
Estimation of internal parameters of a camera is a very important task for photo- and videogrammetric applications. This operation is time-consuming for multiple cameras. The method based on the mobile backlight illuminated calibration board is proposed. Wireless link for the calibration result transmission with the pattern features detection results is applied in the system. The OpenCV library for calibration process and libdc library for real-time image acquisition are applied.
Estymacja parametrów wewnętrznych kamer jest ważnym zadaniem fotogrametrii i wideogrametrii. Wykonanie kalibracji kamer dla wielu kamer jest zadaniem długotrwałym, dlatego tez w artykule zaproponowano system do wspomagania tego procesu. W miejsce pasywnego wzorca kalibracyjnego lub monitora LCD wykorzystano podświetlany panel wraz z transparentnym wzorcem, a obraz z kamery jest rejestrowany z wykorzystaniem systemu Linux dla kamer IIDC (biblioteka libdc) i przetwarzany przez oprogramowanie do kalibracji w czasie rzeczywistym w oparciu o bibliotekę OpenCV. Obraz wzorca informujący zarazem o jakości kalibracji jest przesyłany za pomocą łączą bezprzewodowego Bluetooth do mobilnego systemu wizualizacji wykorzystującego procesor sygnałowy. Zadaniem procesora sygnałowego jest synteza i generacja obrazu analogowego na podstawie danych z procesu kalibracji dla monitora podglądowego LCD zainstalowanego na kamizelce operatora. Do syntezy wykorzystano wielowyjściowy układ transmisji szeregowej synchronicznej pracujący w trybie Network Mode TDM. Wykorzystując większą ilość kanałów modułu ESSI możliwa jest programowo-sprzętowa generacja obrazu w kilku odcieniach szarości lub kolorach. Zaproponowane rozwiązanie nie wymaga konieczności dostępu do monitora komputera, do którego podłączona jest kamera. W artykule porównano także wpływ warunków oświetlenia pomieszczenia na oświetlenie wzorca kalibracji w wariancie pasywnym i z wykorzystaniem podświetlenia.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 11, 11; 1356-1358
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytmy kalibracji stereoskopowego układu kamer i rekonstrukcji sceny trójwymiarowej na podstawie obrazów termowizyjnych
Calibration methods for stereoscopic cameras used in 3D scene reconstruction
Autorzy:
Rzeszotarski, D.
Powiązania:
https://bibliotekanauki.pl/articles/154660.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stereowizja
kalibracja kamer
trójwymiarowa rekonstrukcja
obrazy termowizyjne
stereovision
camera calibration
3D reconstruction
thermal images
Opis:
W niniejszej pracy pojęcie trójwymiarowej rekonstrukcji sceny na podstawie obrazów termowizyjnych jest rozumiane, jako przypisanie każdemu punktowi obrazu termowizyjnego współrzędnych przestrzennych. Kalibracja układu kamery (lub kamer) jest ważnym elementem takiej rekonstrukcji. W artykule opisano algorytmy do kalibracji kamer pod kątem ich zastosowania do trójwymiarowej rekonstrukcji sceny termowizyjnej. Na tle istniejących rozwiązań w omawianej tematyce opisano podejście zaproponowane przez autora. Algorytmy napisano w języku C++ oraz poddano weryfikacji, której wyniki opisano w końcowej części pracy.
In this paper reconstruction of 3D scene refers to assigning 3D coordinates to each pixel of a thermal image. Calibration of cameras is a crucial element of such a system. There is presented classification and review of camera calibration techniques in the paper. The first perspective model of a single camera is given (Fig. 1) and the basics regarding 3D reconstruction by means of a stereoscopic set of cameras are provided (Fig. 2). Classification of 3D scene reconstruction techniques according to calibration algorithms is summed up in Tab. 1. The calibration algorithm of a single camera by means of a special board is described in Section 5. Next, the more detailed description of the algorithms providing extrinsic parameters i.e. the rotation matrix and translation vector between two cameras or two different positions of the same camera is given. Finally, a robust calibration technique proposed by the author is outlined. The stereovision set integrated with a thermal camera used as a test bed for the implemented calibration algorithms is shown in Fig. 4. The obtained results of calibration and reconstruction are presented in Tabs. 3 and 4. The reconstructed object is shown in Fig. 5. According to Tab. 4, the best reconstruction results are obtained by means of a stereovision set consisting of two visual cameras calibrated by means of a classical calibration board (Fig. 3). In the case of a single moving thermographic camera calibrated by means of the method proposed by the author, the obtained recon-struction results are worse; the reconstruction error is about 5 mm, while the distances between the reconstructed points are 300mm (Fig. 5).
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1138-1141
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accuracy analysis of automatic distortion correction
Ocena dokładności automatycznej korekcji dystorsji
Autorzy:
Kolecki, J.
Rzonca, A.
Powiązania:
https://bibliotekanauki.pl/articles/145565.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
camera calibration
radial distortion
disortion correction
accuracy analysis
bundle adjustment
korekcja zniekształceń
analiza dokładności
pomiar fotogrametryczny
Opis:
The paper addresses the problem of the automatic distortion removal from images acquired with non-metric SLR camera equipped with prime lenses. From the photogrammetric point of view the following question arises: is the accuracy of distortion control data provided by the manufacturer for a certain lens model (not item) sufficient in order to achieve demanded accuracy? In order to obtain the reliable answer to the aforementioned problem the two kinds of tests were carried out for three lens models. Firstly the multi-variant camera calibration was conducted using the software providing full accuracy analysis. Secondly the accuracy analysis using check points took place. The check points were measured in the images resampled based on estimated distortion model or in distortion-free images simply acquired in the automatic distortion removal mode. The extensive conclusions regarding application of each calibration approach in practice are given. Finally the rules of applying automatic distortion removal in photogrammetric measurements are suggested.
Publikacja ma na celu przedstawienie wyników automatycznego usuwania dystorsji dla niemetrycznej kamery z obiektywem stałoogniskowym. Z punktu widzenia fotogrametrii pojawia się zasadnicze pytanie, czy dokładność określenia dystorsji dla danego typu obiektywu (a nie egzemplarza) jest wystarczająca, żeby otrzymać oczekiwane dokładności pomiaru fotogrametrycznego. W tym celu wykonano dwa rodzaje obliczeń kontrolnych. Pierwsze obliczenia to kalibracja kamery w wariantach zapewniających szeroką dyskusję wyników, wykonana w oprogramowaniu zapewniającym podanie pełnej analizy dokładności. Dodatkowo każdy wariant został sprawdzony poprzez kalibrację kontrolną, którą policzono na podstawie pomiaru zdjęć z fizycznie usuniętym wpływem dystorsji. Drugi etap obliczeń – analiza dokładności – polegał na wykonaniu pomiarów sprawdzających punktów kontrolowanych na zdjęciach dla wszystkich 3 zestawów przyjętych lub obliczonych elementów orientacji wewnętrznej oraz dystorsji usuniętej automatycznie lub programem, na podstawie wyników kalibracji. W publikacji zamieszczono obszerny komentarz dotyczący praktycznych aspektów stosowania każdej z tych metod kalibracji. Wniosek ostateczny podaje zasady stosowania wyników automatycznej redukcji dystorsji w zastosowaniach fotogrametrycznych.
Źródło:
Geodesy and Cartography; 2015, 64, 1; 3-14
2080-6736
2300-2581
Pojawia się w:
Geodesy and Cartography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kalibracja kamer z zastosowanym warunkiem Scheimpfluga
Camera calibration with Scheimpflug condition
Autorzy:
Tokarczyk, R.
Jędrzejek, M.
Powiązania:
https://bibliotekanauki.pl/articles/130084.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
fotogrametria bliskiego zasięgu
kalibracja kamery
warunek Scheimpfluga
dystorsja obiektywu
close-range photogrammetry
camera calibration
Scheimpflug condition
lens distortion
Opis:
Zastosowanie warunku Scheimpfluga w kamerach powoduje, że dystorsja obiektywu nie jest symetryczna wokół punktu głównego zdjęcia, a przyjęcie tego punktu jako początku promieni radialnych dla dystorsji powoduje znaczące obniżenie dokładności fotogrametrycznego pomiaru. Dodatkowo, zmienia się charakter dystorsji, jej zniekształcenie nie jest kołowe, a eliptyczne. Dotychczasowe rozwiązania problemu polegają na dodaniu do parametrów kalibracji kamery kąta nachylenia płaszczyzny rejestracji w stosunku do płaszczyzn głównych obiektywu kamery i wyznaczenie ich w procesie wyrównania sieci z samokalibracją. W przypadkach stosowania metod jednoobrazowych, wykorzystywanych na przykład w pomiarach z zastosowaniem profili świetlnych, znajomość parametrów kalibracji można ograniczyć tylko do błędów obrazu – przede wszystkim do wpływu dystorsji obiektywu. W pracy podano proste obliczeniowo metody wyznaczenia błędów obrazu dla zdjęć wykonanych kamerą z warunkiem Scheimpfluga. Pierwszy polega na wyznaczeniu wyinterpolowanych poprawek do pomierzonych współrzędnych w oparciu o „mapę” odchyłek otrzymaną na podstawie przekształcenia rzutowego płaskiego wielopunktowego pola testowego na zdjęcie. Druga metoda wymaga obliczenia oprócz parametrów dystorsji również punktu najlepszej symetrii dystorsji wykorzystując odchyłki po transformacji rzutowej. Badania wykonano w oparciu o dane rzeczywiste, jak i symulacyjne. Rezultaty usunięcia wpływu dystorsji pierwszą z metod okazały się znacznie lepsze od drugiej metody, pozwoliły na zmniejszenie wpływu błędu dystorsji do poziomu błędów przypadkowych pomiaru.
Automatic processes of manufacturing supervision with digital cameras often need to employ the Scheimpflug condition. This is quite common when registering profiles with a laser light. The Scheimplug condition is applied in this case because usually the registration plane cannot be set in parallel to the plane of a laser profile. Moreover, the low-light conditions forcing the use of large diaphragm size and low image acquisition distance imply that the depth of field is insufficient. Setting up three planes: lens main, image and profile in a way that they intersect within one edge, causes that the axis of the lens impales image plane at a point distant from the principal point, which in the analytical evaluation of the photogrammetric networks is adopted as the best-distortionsymmetry point. The Scheimpflug condition causes that the lens distortion (a feature significantly influencing the central projection) is not symmetrical around the principal point and, assuming this point as the origin of radial rays, leads to significant reduction of accuracy of measurement. A solution to this problem is to include the incidence angle between the detector array and lens main planes in the calibration parameters and their evaluation in the self-calibration network adjustment. This best solution from the substantive point of view thus needs elaboration of a specific software for self-calibration bundle adjustment, which is costly and time consuming. In this paper the different – computationally easier methods for the evaluation of image errors for the images taken considering the use of a camera with the Scheimpflug condition. The first method involves determination of interpolated corrections to measured coordinates based on a “deviation map” obtained from the projective transform of a planar, multi-point test-field on the image. The second method employs the evaluation of the best-distortion-symmetry point using the deviations evaluated after the projective transform, approximated by a radial and tangential distortion polynomial evaluated regarding this point. The research was conducted using real as well as simulated data.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2010, 21; 385-394
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies