Tytuł:
Comparative analysis of selected wastewater treatment plants
Autorzy:
Nowakowska, Anita
Powiązania:
https://bibliotekanauki.pl/articles/1177394.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
biological wastewater treatment plant
mechanical-biological wastewater treatment plant
wastewater
wastewater management
Opis:
The article presents the classification of wastewater treatment plants and indicates the types of processes occurring during wastewater treatment. The purpose of the article is to get acquainted with the functioning as well as technical and economic differences of biological and mechanical-biological wastewater treatment plant. The author also made a comparative analysis containing a list of wastewater treatment efficiency in the presented treatment plants, as well as compared economic aspects necessary for the operation of these treatment plants.
Źródło:
World Scientific News; 2018, 104; 359-374
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modernizacja zakładów zagospodarowania odpadów na przykładzie instalacji w Gorzowie Wielkopolskim
Modernization of waste management plants exemplified by installation in Gorzów Wielkopolski
Autorzy:
Hryb, W.
Powiązania:
https://bibliotekanauki.pl/articles/357669.pdf
Data publikacji:
2013
Wydawca:
Politechnika Śląska
Tematy:
modernizacja
sortownia
mechanicznio-biologiczne przetwarzanie odpadów
modernization
sorting station
mechanical-biological treatment plant
Opis:
System gospodarki odpadami w Polsce jest obecnie modernizowany w celu dostosowania do przepisów prawa to jest spełnienia obowiązujących poziomów recyklingu i odzysku odpadów jak również ograniczenia ilości frakcji biodegradowalnej trafiającej na składowiska. Powstają nowe sortownie i zakłady biologicznego przetwarzania odpadów, a instalacje już funkcjonujące są modernizowane. W artykule przedstawiono przykład modernizacji zakładu w Gorzowie Wielkopolskim i efekty tej inwestycji.
At the moment waste management system in Poland is modernized with the aim of adjusting the system to the legal regulations, fulfilling binding recycling and recovery levels and limiting the amount of biodegradable fractions which are disposed of in the landfills. New sorting stations and biological treatment plants are founded and existing facilities are modernized. The article presents an example of modernization of a plant in Gorzów Wielkopolski and the effects of the investment.
Źródło:
Archiwum Gospodarki Odpadami i Ochrony Środowiska; 2013, 15, 1; 47-56
1733-4381
Pojawia się w:
Archiwum Gospodarki Odpadami i Ochrony Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of heavy precipitation on the infiltration and inflow into small sewage treatment plants in 2010
Autorzy:
Kaczor, G.
Powiązania:
https://bibliotekanauki.pl/articles/60233.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
heavy rainfall
infiltration
inflow
small sewage treatment plant
sewage treatment plant
sewer system
weather
treatment plant
Malopolska voivodship
Krakow city
mechanical treatment plant
biological treatment plant
modernization
Opis:
The aim of the study was to determine the extent to which heavy rainfall, that occurred in 2010, affected the infiltration into the selected sewage treatment plants in the Małopolskie voivodeship. The research was conducted in four separate sewer systems, located in poviats adjacent to the city of Kraków, discharging sewage to mechanical-biological treatment plants with a capacity below 1000 m3•d-1. The amount of sewage and extraneous water in the average wet year (2008) were used as control. As a result of heavy precipitation in 2010 the sewer system A received 18 539 m3 more extraneous water than in 2008 (increase by 343%), the sewer sys-tem B - 22 822 m3 (increase by 163%), the sewer system C - 109 715 m3 (increase by 248%) and the sewer system D - 30 796 m3 (increase by 303%). Heavy precipitation in 2010 caused the increase of infiltration and inflow by 264% on average in all studied sewer systems compared to the average wet year. As the result of precipitation, whose annual total in 2010 was higher by 65% than the normal value in 2008, there was an increase in the annual share of extraneous water from 5.3 to 19.7% depending on the facility. The volume of extraneous water, which was discharged into the studied treatment plants in 2010 (the period of heavy rainfall), constituted the following share of the annual value: in the sewer system A - 41.3%, in the sewer system B - 21.2%, in the sewer system C - 14.4%, in the sewer system D - 22.9%. Assuming the average gross amount of 3 PLN paid for treatment of 1 m3 of sewage, cost of extraneous water disposal in 2010 amounted from 78 533 PLN to 552 165 PLN, depending on the facility. The results obtained in the present study suggest that eliminating or reducing infiltration and inflow into the analyzed sewer systems would allow for large financial savings associated with reducing costs both for their transport and treatment as well as for modernization of facilities to enhance their hydraulic eapacity.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2011, 12
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of post-sewage waters on relations between exchangeable cations in soils
Autorzy:
Dechnik, I
Filipek, T.
Powiązania:
https://bibliotekanauki.pl/articles/1449943.pdf
Data publikacji:
2001
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
post-sewage water
relationship
soil
municipal waste
cation
biogenic component
soil property
eroded soil
degraded ecosystem
mechanical-biological treatment plant
anthropogenic ecosystem
sewage
Opis:
Research was carried out on the basis of investigations from the years 1996-1998 on the so-called monoliths in the soils derived from loess formations. Properties of those formations were differentiated by landscape and processes of water erosion. It was found out that post-sewage waters (waters received after sewage treatment) from a mechanical-biological sewage treatment plant have a more favourable influence on both the value of acidification indexes and relations between cations in the soils than solid mineral salts.
Źródło:
Acta Agrophysica; 2001, 51; 29-35
1234-4125
Pojawia się w:
Acta Agrophysica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fuzzy models of the biological-chemical processes in the west-water treatment plant
Autorzy:
Szabat, K.
Kowalski, C. J
Powiązania:
https://bibliotekanauki.pl/articles/97453.pdf
Data publikacji:
2010
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
treatment plant
electrical blower
biological-chemical process
fuzzy model
Opis:
In the work issues related to control of the electrical blowers installed in the waste water treatment plant (WWTP) are demonstrated. After a short introduction a description of a real treatment plant is presented. Then the main sewage drives are described. Next the commonly used control strategies for the biological-chemical process are presented. The model ASM1 of the biological chemical transformation used in the advanced MPC (model predictive control) strategy is introduced. Then the fuzzy system based on the TSK model is presented. The ability of the TSK fuzzy system to estimate the biological-chemical variables are demonstrated.
Źródło:
Computer Applications in Electrical Engineering; 2010, 8; 230-241
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the wastewater from chosen food processing industries on a quality of water in the mouth section of River Odra
Wpływ ścieków z wybranych zakładów przemysłu spożywczego na jakość wód powierzchniowych na terenie miasta Szczecina
Autorzy:
Wira, J.
Tarnowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/85105.pdf
Data publikacji:
2000
Wydawca:
Akademia Pomorska w Słupsku
Tematy:
waste water
food processing industry
water quality
mouth section
Odra River
waste water treatment plant
Szczecin city
biological treatment
sewage treatment
biological sewage treatment
Opis:
Influence of the wastewater from chosen food processing industries located in Szczecin on a quality of receiver’s water was presented. The theoretical part of the paper comprises general fundamentals of the biological treatment of the wastewater, the sources of the wastewater and their impact onto a sewerage system and the receiver at meat processing and dairy industries were also presented in this part of the paper. Szczecin Dairy and Szczecin Poultry Processing Company are both equipped with biological wastewater treatment plants. The treated wastewater is discharged to the receivers that are directly linked to River Odra, thus has an impact on the quality of River Odra water. Basing on a performed research on parameters of untreated and treated wastewater, the treatment performance of the wastewater treatment plants was described as well as an attempt to estimation of an impact of the wastewater onto the receiver was made.
W pracy został przedstawiony wpływ wybranych zakładów przemysłu spożywczego zlokalizowanych w Szczecinie na jakość wody w odbiorniku. Teoretyczna część pracy opisuje generalne zasady biologicznego oczyszczania ścieków, źródła ścieków w omawianych zakładach - przetwórstwa mięsnego i mleczarni, a także wpływ tych ścieków na odbiornik. Ścieki ze Szczecińskich Zakładów Drobiarskich „DROBIMEX-HEINTZ” oraz Szczecińskich Zakładów Mleczarskich są oczyszczane w biologicznych oczyszczalniach ścieków. Oczyszczone ścieki są odprowadzane do odbiorników bezpośrednio połączonych z rzeka Odra, w związku z czym maja wpływ na jakość jej wód. W oparciu o przeprowadzone badania parametrów nie oczyszczonych i oczyszczonych ścieków dokonano oceny w/w zakładów na jakość wody w rzece Odrze w jej ujściowym odcinku.
Źródło:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline; 2000, 04
1643-0115
Pojawia się w:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza skuteczności działania oczyszczalni ścieków pracującej w systemie SBR
Performance analysis of sewage treatment plant working in the SBR system
Autorzy:
Bartkowska, I.
Klaus, W.
Powiązania:
https://bibliotekanauki.pl/articles/908416.pdf
Data publikacji:
2013
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
gospodarka ściekowa
projektowanie oczyszczalni
oczyszczalnia ścieków
skuteczność oczyszczania ścieków
sewage treatment
biological sequencing batch reactor
designing sewage treatment plant
sewage treatment plant
effluent treatment effect
Opis:
Technologia oczyszczania ścieków osadem czynnym w systemach porcjowych znana już była na początku XX wieku. W 1912 roku Fowler zastosował do oczyszczania ścieków miejskich w Manchesterze napowietrzanie ścieków strumieniem pęcherzyków powietrza wytwarzanych w sposób pneumatyczny wraz z następującym po nim etapem sedymentacji. W 1914 roku studenci Fowle'a – Ardern i Lockett – zaprezentowali oczyszczanie ścieków w systemie z napełnianiem i dekantacją bez pozbywania się biologicznych osadów nagromadzonych w czasie cyklicznego napowietrzania ścieków.
This paper presents an assessment of wastewater treatment plants operating in the technological sequence of biological reactors (SBR) as an example Olecko. This paper presents qualitative characteristics of raw sewage to the treatment plant infl uent and effl uent. Assesses the work of the treatment on the basis of tests erformed and operating experience. The analysis is based on the results of the following indicators of pollutants: OD5, COD, pH, concentration of total nitrogen, total phosphorus and total suspended solids. A description of modernized in 2009 technology of sewage treatment plant and sewage sludge management was presented.
Źródło:
Ekonomia i Środowisko; 2013, 4; 107-117
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
"Sitkówka" w fazie prób generalnych
Autorzy:
Gładyszowska-Dawid, M.
Powiązania:
https://bibliotekanauki.pl/articles/363968.pdf
Data publikacji:
2010
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
ochrona środowiska
oczyszczalnia ścieków
oczyszczalnia ścieków Sitówka
reaktor biologiczny
biological reactor
environment protection
sewage treatment plant
sewage treatment plant Sitówka
Opis:
Nowy reaktor biologiczny w Oczyszczalni Ścieków .Sitkówka. rozmiarami dorównuje boisku piłkarskiemu, a każdy z czterech zbudowanych tu osadników wtórnych wielkością i kształtem przypomina mały stadion. Zarówno skala obiektów, jak i stopień skomplikowania technologicznego pokazują, jak wiele wysiłku wymaga oczyszczanie ścieków i ich przywrócenie obiegowi wody w przyrodzie. Patrząc na uruchomiony właśnie w ramach projektu Funduszu Spójności Rozbudowa i modernizacja Oczyszczalni Ścieków .Sitkówka. dla miasta Kielce pierwszy ciąg technologiczny oczyszczalni, widać gołym okiem, że warto...
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2010, 5; 48-50
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of carbon source and nitrate concentration on denitrification of high-nitrate wastewater
Autorzy:
Horová, Dorota
Bezucha, Petr
Růžičková, Iveta
Powiązania:
https://bibliotekanauki.pl/articles/207338.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
activated sludge
biological denitrification
sewage treatment plant
osad czynny
oczyszczalnia ścieków
denitryfikacja biologiczna
Opis:
The aim of the present work was to study the applicability of the activated sludge from a municipal wastewater treatment plant for high strength nitrate denitrification process. A sequenced batch reactor operated at initial nitrate concentration in the range from 750 to 8500 mg NO3 -N/dm3 .The effectiveness of various carbon sources on denitrification rate and nitrite accumulation was studied. The average specific denitrification rate was in the range from 58 to 62 mg NO3 -N /(g VSS·h) for ethanol, glycerol, molasses and whey. The denitrification with methanol was not effective.
Źródło:
Environment Protection Engineering; 2020, 46, 1; 73-89
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Antibiotics in WWTP discharge into the Chaobai River, Beijing
Autorzy:
Zhang, C.
Wang, L.
Gao, X.
He, X.
Powiązania:
https://bibliotekanauki.pl/articles/204951.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
antibiotics
PPCPs
pharmaceuticals and personal care products
WWTP
wastewater treatment plant
BAF
biological aerated filter
advanced treatment
Opis:
22 representative antibiotics, including 8 quinolones (QNs), 9 sulfonamides (SAs), and 5 macrolides (MCs) were selected to investigate their occurrence and removal efficiencies in a Wastewater Treatment Plant (WWTP) and their distribution in the receiving water of the Chaobai River in Beijing, China. Water quality monitoring was performed in an integrated way at different selected points in the WWTP to explore the potential mechanism of antibiotics removal during wastewater treatment. Water quality of the Chaobai River wa s also analyzed to examine environmental distribution in a river ecosystem. The results showed that within all the 22 compounds examined, 10 antibiotics were quantifi ed in wastewater influent, 10 in effluent, and 7 in river. Sulfadiazine (SDZ, 396 ng/L) and Sulfamethazine (SMZ, 382 ng/L) were the dominating antibiotics in the influent. Both the conventional treatment and advanced Biological Aerated Filter (BAF) system was important for the removal of antibiotics from the wastewater. And the concentrations of selected antibiotics were ranged from 0–41.8 ng/L in the effluent-receiving river. Despite the fact that the concentrations were reduced more than 50% compared to effluent concentrations, WWTP discharge was still regarded as a dominant point-source input of antibiotics into the Chaobai River.
Źródło:
Archives of Environmental Protection; 2016, 42, 4; 48-57
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel methods of testing biological activity of seed dressing fungicides against snow mould Microdochium nivale
Autorzy:
Krzyzinska, B
Maczynska, A.
Sikora, H.
Powiązania:
https://bibliotekanauki.pl/articles/65613.pdf
Data publikacji:
2001
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fungicide
seed treatment
biological activity
snow mould
plant protection
Microdochium nivale
testing method
Opis:
In the Institute of Plant Protection Branch in Sośnicowice an investigation was performed on establishing novel methods for testing biological activity or seed dressings against snow mould (Microdochium nivale). Seeds of winter wheat used for the experiments in artificial conditions were disinfected in sodium hypochlorite, subsequently infected with the pathogen, and treated with seed dressing fungicides (Baytan Universal 19.5 WS, Zaprawa Funaben T, Maxim 025 FS, Raxil Extra 515 FS and Vitavax 200 FS). In laboratory tests inoculation with conidial suspension was applied, and in climatic chamber experiments either conidial suspension or inoculum grown on sand-cornmeal medium was used. The field experiment with the same seed dressings was carried out on naturally infested plots, and the disease developed under snow cover lasting for 58 days. Two novel climatic chamber methods (Z and PK) proved to be suitable for testing biological activity of seed dressing fungicides against snow mould (M. nivale) as correlation coefficients with field results at P=0.05 were 0.9760 and 0.9453. Method Z was recognised as more suitable. Differences between seed dressings were statistically insignificant. The laboratory method was recognised as useful for controlling the pathogen (M. nivale), but its usefulness for controlling the disease (snow mould) may not be sufficient under a range of different winter conditions.
W Oddziale Instytutu Ochrony Roślin w Sośnicowicach są prowadzone badania w celu rejestracji nowych zapraw między innymi na pleśń śniegową wywoływaną przez Microdochium nivale. Z powodu coraz częściej występujących trudności oceny skuteczności działania zapraw w ochronie ozimin przed tą chorobą (z jej typowymi objawami) i koniecznością potwierdzania w kontrolowanych warunkach objawów porażenia roślin przez M. nivale będącego również sprawcą m.in. fuzaryjnej zgorzeli siewek prowadzone były badania nad nowymi metodami oceny aktywności biologicznej zapraw przeciw pleśni śniegowej. Oceniano skuteczność działania kilku zapraw z różnych grup chemicznych i o różnym mechanizmie działania w warunkach naturalnych oraz w warunkach sztucznej infekcji w doświadczeniach komorowych (Metoda Z i metoda PK) i laboratoryjnych. Współczynniki korelacji (P=0,05) dla wyników uzyskanych w komorze klimatycznej (metody Z i PK) oraz w laboratorium z wynikami doświadczenia polowego, w którym wystąpiła pleśń śniegowa, były wysokie i wynosiły odpowiednio 0,9760, 0,9453 i 0,9738. Przydatność metody komorowej Z do oceny biologicznej skuteczności działania zapraw nasiennych przeciwko pleśni śniegowej oceniono wyżej niż przydatność metody PK. Stwierdzono, że chociaż metoda laboratoryjna jest łatwa i prosta, to służy raczej do oceny wpływu zapraw na sprawcę choroby (grzyb M. nivale), a nie na występowanie pleśni śniegowej.
Źródło:
Journal of Plant Protection Research; 2001, 41, 4
1427-4345
Pojawia się w:
Journal of Plant Protection Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza narażenia zawodowego pracowników na szkodliwe czynniki biologiczne w typowej miejskiej oczyszczalni ścieków
Autorzy:
Nowojewski, A.
Mniszek, W.
Powiązania:
https://bibliotekanauki.pl/articles/370795.pdf
Data publikacji:
2006
Wydawca:
Wyższa Szkoła Zarządzania Ochroną Pracy w Katowicach
Tematy:
oczyszczalnia ścieków
czynniki biologiczne
narażenie zawodowe
wastewater treatment plant
biological factors
occupational hazards
Opis:
W publikacji przedstawiono narażenie na mikrobiologiczne szkodliwe czynniki w oczyszczalni ścieków. Na podstawie danych z piśmiennictwa wybrano główne zagrożenia mikrobiologiczne i opisano ich potencjalne skutki zdrowotne dla pracowników w oczyszczalni ścieków. Ocenę narażenia na wybrane bakterie patogenne wykonano w typowej oczyszczalni ścieków miejskich w Polsce. Opisano metody pobierania próbek, a także analityczną procedurę ilościowych pomiarów patogenów na stanowiskach pracy w wybranej oczyszczalni ścieków. W rezultacie oceniono higieniczne warunki pracy na stanowiskach pracy.
Exposure for the hazardous microbiological agents in wastewater treatment plant are presented in this article. On the base of literature the principals microbiological hazards were identifi ed and the potential health effects resulting from exposure of men working in wastewater treatment plant are described. Exposure assessment on some pathogenic bacteria’s present in ambient air in the workplaces in one typical municipal wastewater treatment plant in Poland was made. The sampled method as well as the analytical procedure to quantitative measures of pathogens in work places are described in this article. In the result the hygienic conditions in the work places were assessed.
Źródło:
Zeszyty Naukowe Wyższej Szkoły Zarządzania Ochroną Pracy w Katowicach; 2006, 1(2); 7-34
1895-3794
2300-0376
Pojawia się w:
Zeszyty Naukowe Wyższej Szkoły Zarządzania Ochroną Pracy w Katowicach
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pollutants Removal Efficiency in The Hydroponic Lagoon of The Wastewater Treatment Plant
Autorzy:
Jakubaszek, Anita
Powiązania:
https://bibliotekanauki.pl/articles/27314840.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
wastewater treatment plant
wastewater treatment
hydroponic lagoon
mechanical-biological wastewater
oczyszczalnia ścieków
oczyszczanie ścieków
laguna hydroponiczna
oczyszczanie mechaniczno-biologiczne
Opis:
Wastewater treatment in semi-natural systems, such as a hydroponic lagoon operating as the third stage of treatment, is becoming more and more popular because of the efficiency of organic matter and nutrient removal. The article presents an analysis of the efficiency of pollutant removal at the mechanical-biological wastewater treatment plant in Gronów with a capacity of Qd = 1125m3/day and a load of 9375 PE. The wastewater treatment plant operates on the basis of activated sludge and biomass settling technology on submerged flow beds. The treatment plant is characterized by a very high variability of wastewater inflow during the year due to periodic inflow of wastewater from tourist resorts in Łagów. The average efficiency of removing pollutants from wastewater was: BOD5 - 98.5%, COD - 92.8%, total suspended solids - 93.2%, total nitrogen - 86.1% and total phosphorus - 69.5%. The study showed that the use of a hydroponic lagoon in the technological system improved the efficiency of wastewater treatment by 1.7% for BOD5, 0.9% - COD, total suspended solids by 4.3%, 6.4% for total nitrogen and total phosphorus - 3.3%.
Źródło:
Civil and Environmental Engineering Reports; 2022, 32, 4; 293--305
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis and evaluation of sewage treatment plant operation
Analiza i ocena funkcjonowania oczyszczalni ścieków
Autorzy:
Gawdzik, J.
Długosz, J.
Powiązania:
https://bibliotekanauki.pl/articles/388727.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
waste water treatment plant
BOD5
biological treatment
removal efficiency
oczyszczalnia ścieków
BZT5
biologiczne oczyszczanie ścieków
skuteczność usuwania zanieczyszczeń
Opis:
The paper presents the analysis and evaluation of six sewage treatment plants. The effectiveness of wastewater treatment was assessed for the following treatment facilities: Barcza (O1), Opatow (O2), Ostrowiec (O3), Starachowice (O4), Sandomierz (O5) and Piaseczno (O6). The evaluation of plant operation was based on the amount of reduction of five selected pollution indicators: BOD5, COD, total suspension, total nitrogen and total phosphorus. In addition, COD/BOD5 ratios were determined, the reliability coefficient (RC) was calculated and the degree of use of sewage treatment plant capacity, in relation to pollutant loads, was assessed. The paper also analyzes the non uniformity coefficient that characterizes variation in sewage flow.
W pracy przedstawiono analizę oraz ocenę funkcjonowania sześciu oczyszczalni ścieków. Ocenie efektywności systemu oczyszczania poddano oczyszczalnie ścieków Barcza (O1), a także w Opatowie (O2), Ostrowcu Świętokrzyskim (O3), Starachowicach (O4), oraz w Sandomierzu (O5) i Piasecznie (O6). Oceny poprawności działania oczyszczalni oparto na wielkości redukcji 5 wybranych wskaźników zanieczyszczeń: BZT5, ChZT, zawiesina ogólna, azot ogólny i fosfor ogólny. Poza tym dokonano obliczeń stosunku ChZT/BZT5, jak i również obliczono współczynnik niezawodności WN oraz stopień wykorzystania przepustowości oczyszczalni ścieków ze względu na ładunki zanieczyszczeń. W pracy przeanalizowano również wartość współczynnika nierównomierności, który charakteryzuje zmienność dopływu ścieków.
Źródło:
Ecological Chemistry and Engineering. A; 2014, 21, 2; 199-209
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warbud buduje "Czajkę"
Autorzy:
Ambroża-Urbanek, B.
Powiązania:
https://bibliotekanauki.pl/articles/364196.pdf
Data publikacji:
2010
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
ekologia
inwestycje
oczyszczalnia ścieków Czajka
reaktor biologiczny
Warszawa
biological reactor
ecology
investment
Sewage-Treatment Plant Czajka
Warsaw
Opis:
Po latach protestów i przymiarek ruszyła wreszcie inwestycja rozbudowy i modernizacji Oczyszczalni Ścieków "Czajka". Ta największa inwestycja ekologiczna Warszawy, ma niebagatelne znaczenie nie tylko dla środowiska. Obok budowy Mostu Północnego i metra to inwestycja kluczowa dla funkcjonowania stolicy.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2010, 3; 22-25
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies