Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "bioaerozol" wg kryterium: Temat


Tytuł:
Określenie narażenia osób biegających w wybranych punktach Krakowa na aerozol mikrobiologiczny
Evaluation of runners exposure to microbial aerosol in selected sites in Cracow
Autorzy:
Wolny-Koładka, Katarzyna
Szatan, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/1177580.pdf
Data publikacji:
2015
Wydawca:
Instytut Medycyny Wsi
Tematy:
"Kraków"
"bieganie"
"bioaerozol"
"mikroorganizmy"
"powietrze"
Opis:
Introduction. The purpose of this study was to evaluate the microbiological quality of the air at the selected places which are located in Cracow and also to determine the influence of weather conditions, such as temperature, humidity and pollination on the number of microorganisms. Material and methods. Samples of air were taken during spring, summer, autumn and winter. The analyses were carried out by using a single-stage MAS-100 impactor (Merck) and repeated three times. Results were compared to guidelines which are included in Polish Standards. Results. The results of the study suggest that there is correlation between seasons and number of microorganisms. Moreover the number of microbes depends on location. The highest concentration of all groups of microorganisms occurred in summer and autumn. Conversely the lowest number of microbes occurred in winter. The results indicated that the composition of bioaerozol is typical and consists of fungi: Cladosporium spp., Mucor spp., Penicillium spp., Alternaria spp., Trichothecium spp., Fusarium spp., bacteria: Micrococcus spp., Diplococcus spp., Tetracoccus spp., Streptobacillus spp., Staphylococcus spp. and actinomycetes. Conclusions. The results revealed that there is a big difference in the occurence of microorganisms and it depends on season and location as well. However our study indicates that air does not pose a microbiological threat to runners.
Wstęp. Celem pracy była ocena jakości mikrobiologicznej powietrza w wybranych punktach zlokalizowanych na terenie Krakowa. Określono także wpływ warunków meteorologicznych: temperatury, wilgotności oraz zapylenia na liczebność drobnoustrojów. Materiał i metody. Powietrze do badań pobierano wiosną, latem, jesienią i zimą 2014 r., metodą uderzeniową przy użyciu impaktora typu MAS-100 (Merck). Analizę wykonano w trzech powtórzeniach, wyniki porównano z wytycznymi zawartymi w Polskich Normach. Wyniki. Stwierdzono zależność między porą roku a liczebnością badanych drobnoustrojów stanowiących bioaerozol. Ich liczebność różniła się również w zależności od punktu poboru. Lato i jesień okazały się być porami roku, w czasie których wszystkie badane grupy mikroorganizmów występowały w powietrzu w największym stężeniu. Natomiast zima okazała się być najmniej sprzyjającą porą roku dla drobnoustrojów. Wbadanych próbkach stwierdzono występowanie typowej mikroflory powietrza. Zidentyfikowano grzyby należące do rodzajów: Cladosporium, Mucor, Penicillium, Alternaria, Trichothecium i Fusarium. Wśród bakterii zidentyfikowano Micrococcus spp., Diplococcus spp., Tetracoccus spp., Streptobacillus spp., Staphylococcus spp. oraz promieniowce. Wnioski. Stwierdzono, duże zróżnicowanie w występowaniu drobnoustrojów w zależności od pory roku i punktu poboru powietrza. Przeprowadzone badania wykazały, że powietrze w badanych lokalizacjach nie stanowiło zagrożenia mikrobiologicznego dla osób biegających.
Źródło:
Medycyna Środowiskowa - Environmental Medicine; 2015, 18, 2; 39-47
1505-7054
2084-6312
Pojawia się w:
Medycyna Środowiskowa - Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody detekcji wirusów w różnych środowiskach pracy
Methods of virus detection in various work environment
Autorzy:
Stobnicka-Kupiec, A.
Górny, R.
Powiązania:
https://bibliotekanauki.pl/articles/137746.pdf
Data publikacji:
2018
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
wirusy
środowisko pracy
bioaerozol
wymazy powierzchniowe
PCR
viruses
occupational environment
bioaerosol
surface swabs
Opis:
Wirusy to szkodliwe czynniki biologiczne, które mogą stwarzać zagrożenie dla pracowników wielu grup zawodowych. Informacje o występowaniu wirusów w różnych środowiskach pracy są bardzo nieliczne, przede wszystkim z uwagi na trudności analityczne związane z ich rutynowym wykrywaniem. Kontrole sanitarne stanowisk pracy oceniające stopień ich za-nieczyszczenia drobnoustrojowego nie są efektywne wobec wirusów, co sprawia, że ryzyko zawodowe pracowników narażonych na czynniki biologiczne jest w dalszym ciągu niedoszacowane. Taki stan rzeczy w zasadniczy sposób uniemożliwia prawidłowe za¬rządzanie bezpieczeństwem pracy. Efektywność oznaczania wirusów w próbkach środowiskowych jest uzależniona zarówno od sposobu pobierania i transportu próbek, jak i od techniki izolacji materiału genetycznego wirusa oraz metody jego detekcji. Celem niniejszej publikacji jest próba krytycznego przeglądu piśmiennictwa przedmiotu w celu określenia najefektywniejszej i najkorzystniejszej metody oznaczania wirusów w środowisku pracy. Taka metoda mogłaby posłużyć jako rutynowa w ocenie zagrożenia wirusami na różnych stanowiskach pracy. W artykule omówiono: metodykę pobierania próbek pod kątem analizy obecności wirusów, metody izolacji wirusowych kwasów nukleinowych oraz sposoby ich detekcji na podstawie: aktywności wirusa, metod biologii molekularnej oraz testów immunoenzymatycznych.
Viruses are harmful biological agents, which can pose a risk for workers from different occupational groups. Information regarding the occurrence of viruses in occupational environment is still scarce, primarily due to analytical difficulty of their routine detection. Hygiene control applied for microbiological contamination are not effective in case of viruses, so the occupational risk for workers exposed to biological agents is still underestimated. Such a state of affairs fundamentally precludes a proper management of occupational safety. The effectiveness of virus detection in the environmental samples depends on methods of sampling and transport, and isolation and identification method. The aim of this paper is an attempt to critically review the literature of the subject, determination of the best and the most effective method of virus detection and identification in the occupational environment, which could be used as a routine methodology for assessing the risk of viruses in various workplaces. The article discusses methods of viral samples collection, viral nucleic acid isolation, and, their detection based on viral activity, molecular biology and immunoenzymatic assays.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2018, 3 (97); 5-18
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szkodliwe czynniki biologiczne w środowisku pracy zakładów przemysłu mleczarskiego
Harmful biological agents in the working environment of dairy plant workers
Autorzy:
Stobnicka-Kupiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/180548.pdf
Data publikacji:
2018
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
czynniki biologiczne
bioaerozol
przemysł mleczarski
harmful biological agents
bioaerosol
milk industry
Opis:
Wśród zagrożeń zawodowych pracowników zakładów przemysłu mleczarskiego wymienić należy kontakt z czynnikami biologicznymi transportowanymi jako bioaerozol emitowany w trakcie procesu produkcji, kontakt z surowcem odzwierzęcym, jakim jest surowe mleko, czy tez z samymi zwierzętami, w przypadku małych przydomowych zakładów przetwórstwa mleka. Pracownicy zakładów przemysłu mleczarskiego w trakcie wykonywanych czynności zawodowych są narażeni na bezpośredni kontakt ze szkodliwymi czynnikami biologicznymi, takimi jak bakterie, grzyby i wirusy, które mogą stać się przyczyna różnych chorób i dolegliwości zdrowotnych. W związku z tym głównymi elementami prewencji zagrożeń zawodowych w tej grupie pracowników powinna być rzetelna ocena ryzyka oraz stosowanie odpowiednich środków profilaktycznych.
Occupational hazards for dairy plant workers include contact with bioaerosols emitted during the production process, contact with raw milk, or with animals in the case of small home based milk processing plants. Dairy plant workers can be exposed to biological agents, such as bacteria, fungi and viruses, which are responsible for various diseases and adverse health outcomes. Therefore, reliable risk assessment and appropriate preventive measures are key to occupational hazard prevention among this group of workers.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2018, 4; 8-11
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czynniki mikrobiologiczne na pokładzie lekkich samolotów pasażerskich
Microbial Agents on Board of Light Passenger Aircrafts
Autorzy:
Stobnicka, A.
Górny, R.
Gołofit-Szymczak, M.
Cyprowski, M.
Ławniczek-Wałczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818069.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
lekkie samoloty pasażerskie
zanieczyszczenie powietrza
bakterie
grzyby
bioaerozol
light passenger aircrafts
air contamination
bacteria
fungi
bioaerosol
Opis:
Light passenger aircrafts, also known as „air taxis”, are a fast and comfortable way of transport, which becomes more and more popular nowadays. However, there is a lack of publications regarding harmful biological agents in the cabin air of light passenger aircrafts. The aim of the study was a quantitative and qualitative evaluation of microbial contamination of cabin air in eight light passenger aircrafts with open cabin type and two helicopters. The bioaerosol sampling was carried out with a stationary, volumetric method using MAS-100 NT impactor. The concentration of microorganisms was expressed as CFU/m3.The highest concentration of bacteria was detected in the helicopter Robinson R44 Raven 2 I (175 CFU/3), while the highest concentration of fungi was detected in the plane model TB9 Socata Tampico (385 CFU/m3). Kruskal-Wallis test did not show any statistically significant difference in the concentration of microorganisms in the air between the tested aircrafts, and between them and the outside background.The predominant groups of microorganisms in bioaerosols were fungi and Gram-positive cocci, which constituted 31.1-83.0% and 5.6-62.2% of the total microbiota, respectively. Sixteen species of bacteria belonging to the 8 types and 14 species of fungi belonging to 13 genera were identified in the samples.The qualitative analysis showed the presence of bacterial and fungal saprophytic strains belonging to the 1. risk group, and species belonging to the 2. risk group (Bacillus subtilis, Streptomyces spp.). Taking into account the influence of temperature and relative humidity on the concentration of bacteria and fungi in the air, it was observed that the higher temperature determined the higher concentration of bacteria, but there was no such relationship concerning fungi. Relative humidity did not significantly determine the concentration of bioaerosols.Our results indicate that the concentrations of bacteria and fungi in the cabin air were very low. However, even such an environment cannot be considered as free from pathogens. As shown by the results, the bioaerosols in the cabin air of light passenger aircrafts may contain potentially pathogenic bacteria and fungi belonging to the 2. risk group. However, bioaerosols may contain potentially pathogenic bacteria and fungi belonging to the 2. risk group. Direct contact with the afore-mentioned microorganisms, especially in the case of people with weakened immunity systems, can cause adverse health effects, as well as allergic reactions.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 492-505
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czynniki mikrobiologiczne na terenie wybranych krajowych portów lotniczych
Microbiological Agents at Selected Domestic Airports
Autorzy:
Stobnicka, A.
Gołofit-Szymczak, M.
Górny, R.
Powiązania:
https://bibliotekanauki.pl/articles/1813774.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
szkodliwe czynniki biologiczne
bioaerozol
terminal lotniczy
harmful biological agents
bioaerosol
airport terminal
Opis:
Jednym z zagrożeń, zarówno dla pasażerów, jak i dla pracowników terminali lotniczych są szkodliwe czynniki biologiczne pochodzące z instalacji wentylacyjnych i przewożonego bagażu oraz te emitowane przez pasażerów. Wspomniane mikroorganizmy bakteryjne i grzybowe mogą wywierać niekorzystny wpływ na organizm człowieka poprzez działanie toksyczne, drażniące i alergizujące. W piśmiennictwie przedmiotu brakuje danych dotyczących zanieczyszczenia powietrza i powierzchni na terenie lotnisk. Celem niniejszej pracy była ocena ilościowa i jakościowa próbek bioaerozoli i wymazów powierzchniowych pobranych na terenie wybranych krajowych portów lotniczych. Badania zostały przeprowadzone w czasie siedmiu miesięcy, w okresie od kwietnia do października na terenie 3 krajowych terminali lotniczych, z których każde obsługuje powyżej 2 mln pasażerów. Pobieranie próbek powietrza przeprowadzone zostało stacjonarnie, metodą wolumetryczną za pomocą impaktora MAS (model 100, Merck, Darmstadt, Niemcy). Próbki wymazów powierzchniowych pobierano sterylną wymazówką zwilżoną solą fizjologiczną z wykorzystaniem jednorazowego sterylnego szablonu o powierzchni 100 cm2 (MEUS S.R.L., Piove Di Sacco, Włochy). Stężenie mikroorganizmów w powietrzu wyrażano w jednostkach tworzących kolonie na 1 m3, [jtk/m3] natomiast stężenie mikroorganizmów na powierzchniach w jednostkach tworzących kolonie na 1 cm2 powierzchni [jtk/cm2]. Uzyskane dane pomiarowe opracowano statystycznie w oparciu o test Kruskala-Wallis’a oraz analizę korelacji Spearman’a z wykorzystaniem programu STATISTICA. Identyfikację mikroorganizmów przeprowadzono w oparciu o analizę makroskopową i mikroskopową cech morfologicznych kolonii, uzupełnioną w przypadku bakterii i drożdży o analizę ich cech biochemicznych z zastosowaniem testów diagnostycznych API. Najwyższe średnie stężenie bakterii w powietrzu odnotowano w hali głównej (800 jtk/m3), natomiast najwyższe średnie stężenie grzybów w hali przylotów (250 jtk/m3). Najbardziej zanieczyszczonymi powierzchniami, pod kątem obecności zarówno bakterii (169 jtk/cm2), jak i grzybów (16 jtk/cm2) były taśmy bagażowe w punkcie kontroli bezpieczeństwa. W próbkach powietrza i na powierzchniach dominującą grupą mikroorganizmów były bakterie, które stanowiły odpowiednio od 40% do 100% oraz od 88,6% do 100% całości mikrobioty. Temperatura powietrza oraz wilgotność względna powietrza nie determinowała w sposób znaczący wielkości obserwowanych stężeń bioaerozoli. Jak wskazują wyniki analizy jakościowej, w bioaerozolach i na powierzchniach na terenie terminali lotniczych mogą występować zarówno bakteryjne i grzybowe szczepy saprofityczne należące do grupy 1. zagrożenia, jak i gatunki zaliczane do grupy 2. zagrożenia (Staphylococcus aureus, Streptomyces spp.), które mogą być przyczyną różnych chorób i dolegliwości zdrowotnych.
One of the hazards, both for passengers and for the workers at the airport terminals, are harmful biological agents emitted from the ventilation system, transported baggage and emitted by the passengers. These bacteria and fungi can cause adversely health effects on the human body through toxic, irritating and allergenic action. The data regarding microbial characteristic of bioaerosols and surfaces at the airports are scarce. The aim of the study was a quantitative and qualitative evaluation of microbial contamination of bioaerosols and surface swabs collected at selected domestic airport terminals. The samples were collected during 7 months from April to October at 3 domestic airport terminals. Each of them serves over 2 mln passengers. Air sampling was carried out with stationary, volumetric method using the MAS impactor (model 100, Merck, Darmstadt, Germany). Samples of surface swabs were collected with a sterile swab soaked with 0,9% NaCl with a disposable sterile template of 100 cm2 area (MEUS S.R.L., Piove Di Sacco, Italy). The concentration of microorganisms in bioaerosols was expressed in colony forming units per 1 m3 [CFU/m3] and the concentration of microorganisms on surfaces in colony forming units per 1 cm2 surface [CFU/cm2]. Statistical analyses were carried out with Kruskal-Wallis and Spearman correlation test using STATISTICA. Identification of microorganisms was based on macroscopic and microscopic analysis of morphological features of colonies, supplemented, in the case of bacteria and yeasts, with biochemical analysis using API diagnostic kits. The highest concentration of bacteria was detected in the main hall (800 CFU/m3), while the highest concentration of fungi in the arrivals hall (250 CFU/m3). The most contaminated surfaces, both with bacteria (169 CFU/cm2) and fungi (16 CFU/cm2) were luggage straps at the security check area. The predominant group of microorganisms in bioaerosols as well as on surface were bacteria, which constitued 40% to 100% and 88.6% to 100% of the total microbiota, respectively. The air temperature and relative humidity of the air did not significantly determine the concentration of bioaerosols. The qualitative analysis showed the presence of bacterial and fungal saprophytic strains belonging to the 1. risk group, and species belonging to the 2. risk group (Staphylococcus aureus, Streptomyces spp.), which are responsible for numerous adverse health outcomes and diseases.
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 2; 1147-1167
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szkodliwe czynniki biologiczne w środowisku pracy personelu odprawy biletowo-bagażowej w portach lotniczych
Harmful biological agents in the working environment of airport check-in staff
Autorzy:
Stobnicka, A
Górny, R. L.
Gołofit-Szymczak, M.
Cyprowski, M.
Ławniczek-Wałczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/180158.pdf
Data publikacji:
2015
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
szkodliwe czynniki biologiczne
bioaerozol
odprawa biletowo-bagażowa
ruch lotniczy
harmful biological agents
bioaerosols
airport check-in
air traffic
Opis:
Do zagrożeń zawodowych pracowników odprawy biletowo-bagażowej w portach lotniczych należy kontakt z czynnikami biologicznymi i transportowanymi jako bioaerozol emitowany z systemu wentylacji, jak również tymi pochodzącymi z organizmów pasażerów, przewożonego bagażu oraz zwierząt. Pracownicy punktu odprawy biletowo-bagażowej w trakcie wykonywanych czynności zawodowych są narażeni na bezpośredni kontakt ze szkodliwymi czynnikami biologicznymi, takimi jak bakterie, grzyby i wirusy, które mogą być przyczyną różnych dolegliwości i chorób. W związku z tym, w prewencji zagrożeń zawodowych dotyczących tej grupy pracowników należy uwzględnić przede wszystkim rzetelną ocenę ryzyka oraz stosowanie odpowiednich środków profilaktycznych.
Occupational hazards to which airport check-in staff are exposed result from contact with bioaerosols emitted from ventilation systems, and biological agents derived from passengers' bodies, luggage and possibly animals. Airport check-in staff can be exposed to contact with harmful biological agents such as bacteria, fungi and viruses, which are responsible for numerous adverse health outcomes and diseases. Therefore, reliable risk assessment are the use of appropriate preventive measures are key aspects of occupational hazard prevention among workers in this group.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2015, 3; 16-18
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The evaluation of microbial contamination in the working environment of tanneries
Ocena zanieczyszczenia mikrobiologicznego na stanowiskach pracy w garbarniach
Autorzy:
Skóra, Justyna
Gutarowska, Beata
Stępień, Łukasz
Otlewska, Anna
Pielech-Przybylska, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/2166284.pdf
Data publikacji:
2014-10-28
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
garbarnia
bioaerozol
zanieczyszczenie mikrobiologiczne
wskaźniki mikrobiologiczne
tanneries
bioaerosols
microbial contamination
microbial indicators
Opis:
Background: Due to their animal material processing, tannery workers may be exposed to biological agents. The aim of the study was the microbial contamination assessment of tanneries with different production specifications. Health risk was estimated based on particle size distribution. Moreover, indicators of microbial contamination of tanneries were selected. Materials and Methods: The studies were conducted in 2 types of tanneries - processing raw hides and producing chrome-tanned leather. Air was sampled with MAS-100 Eco Air Sampler, leathers using RODAC Envirocheck® contact plates and swab method, microbial numbers were determined by a culture method. For the bioaerosols size distribution analysis, a six-stage Andersen sampler was used; identification was performed using microscopy and biochemical methods. Microbial contamination was identified by 16S RNA and ITS1/2 rDNA analysis for bacteria and fungi respectively. Results: The microbial number in the air ranged between 1.2×10³ and 3.7×10³ CFU/m³. While on the leather, it ranged between 7.6×10¹ and 5.5×10⁵ CFU/100 cm². Bacteria dominated in the tanneries (air: 51-92%, leathers: 60-100%). Results indicate that potential health risks arise from the fungal small bioaerosol particles presence (0.65-2.1 μm). Eleven indicator microorganisms were determined: B. pumilus, B. subtilis, B. cereus, C. lubricantis, C. cladosporioides, P. commune, P. echinulatum, P. chrysogenum, P. crustosum, C. parapsilosis and C. albidus. Conclusions: Microbial contamination evaluation in the tanneries showed the increased bacteria and fungi number in the air in relation to the outdoor air, which indicates an occupational inhalation risk to workers. The designated indicators of microbial contamination in the tanneries are associated with their specific and potentially pathogenic working environment. Med Pr 2014;65(1):15–32
Wstęp: Z powodu przetwarzania surowca zwierzęcego w garbarniach pracownicy mogą być narażeni na czynniki biologiczne. Celem badań była ocena zanieczyszczenia mikrobiologicznego w garbarniach o różnej specyfice produkcji. Określono także ryzyko zdrowotne w oparciu o rozkład ziarninowy bioaerozolu. Ponadto wyznaczono wskaźniki zanieczyszczenia mikrobiologicznego w garbarniach. Materiał i metody: Badania przeprowadzono w dwóch rodzajach garbarni - przetwarzających skóry surowe i chromowo garbowane (wet blue). Powietrze pobierano próbnikiem MAS-100 Eco, próby ze skór, używając płytek odciskowych RODAC Envirocheck® i metody tamponowej, a liczbę mikroorganizmów określano metodą hodowlaną. Rozkład cząstek biooaerozolu wykonano z użyciem 6-stopniowego impaktora Andersena. Identyfikację drobnoustrojów wykonano metodą mikroskopową i testami biochemicznymi. Wskaźniki zanieczyszczenia mikrobiologicznego identyfikowano, analizując odpowiednio dla bakterii i grzybów sekwencje 16S RNA i ITS1/2 rDNA. Wyniki: Liczebność mikroorganizmów w powietrzu w garbarniach kształtowała się w granicach 1,2×10³-3,7×10³ jtk/m³. Skóry były zanieczyszczone mikrobiologicznie w granicach 7,6×10¹-5,5×10⁵ jtk/100 cm². W garbarniach dominowały liczbowo bakterie (w powietrzu: 51-92%, na skórach: 60-100%). Wskazano na zagrożenie zdrowotne wynikające z obecności cząstek bioaerozolu grzybowego o rozmiarach 0,65-2,1 μm. Wyznaczono 11 gatunków drobnoustrojów wskaźnikowych dla garbarni: B. pumilus, B. subtilis, B. cereus, C. lubricantis, C. cladosporioides, P. commune, P. echinulatum, P. chrysogenum, P. crustosum, C. parapsilosis i C. albidus. Wnioski: Ocena zanieczyszczenia mikrobiologicznego w garbarniach wykazała podwyższoną liczebność bakterii i grzybów w powietrzu w stosunku do powietrza atmosferycznego, co świadczy o występowaniu narażenia inhalacyjnego pracowników. Wyznaczone wskaźniki zanieczyszczenia mikrobiologicznego w garbarni są związane ze specyfiką środowiska pracy i potencjalnie chorobotwórcze. Med. Pr. 2014;65(1):15–32
Źródło:
Medycyna Pracy; 2014, 65, 1; 15-32
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of bioaerosols in the air around the facilities of waste collection and disposal
Autorzy:
Roodbari, A.
Naddafi, K.
Javid, A.
Powiązania:
https://bibliotekanauki.pl/articles/207127.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
utylizacja odpadów
aerozole
stężenie mikroorganizmów
bioaerozol
bakterie
zbieranie odpadów
gospodarka odpadami
zanieczyszczenie powietrza
waste disposal
aerosols
bacteria
microbial concentrations
bioaerosol
total bacteria
waste collection
waste management systems
air contamination
Opis:
Exposure to bioaerosols at various stages of waste management system (collection, transfer and disposal) has been evaluated by recording of the bacterial and fungal concentrations in the air around these facilities. Regardless of the season, the total bacteria and total fungi were detected for all sampies, whereas the fungal genera were not. The bioaerosol concentrations measured in the waste collection bins were significantly higher than those of the transfer station and landfill site. The mean microbial concentrations at wastes container bins and in-operation trench exceeded the Iran outdoor bioaerosol guidelines (850 CFU/m3), thus suggesting the need for remedial action regarding microorganisms, in order to reduce the exposure at the wastes management system.
Źródło:
Environment Protection Engineering; 2013, 39, 4; 105-112
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zagrożeń mikrobiologicznych w powietrzu wewnętrznym na przykładzie zanieczyszczeń w wybranych pomieszczeniach Szkoły Głównej Służby Pożarniczej
Analysis of microbiological hazards in the indoor air (of the selected rooms of the Main School of Fire Service)
Autorzy:
Prędecka, S.
Kosut, S.
Powiązania:
https://bibliotekanauki.pl/articles/137066.pdf
Data publikacji:
2017
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
mikroorganizmy
bioaerozol
czystość mikrobiologiczna powietrza wewnątrz budynku
microorganisms
bioaerosol
microbiological purity of the air inside the building
Opis:
W artykule dokonano analizy zanieczyszczeń mikrobiologicznych powietrza w wybranych pomieszczeniach Szkoły Głównej Służby Pożarniczej. Zebrany materiał został poddany badaniu przy pomocy dwóch metod: metody sedymentacyjnej Kocha oraz metody zderzeniowej (impakcyjnej), z wykorzystaniem próbnika powietrza MAS-100 Eco. Otrzymane wyniki badań zestawiono z normatywami higienicznymi i zaproponowano działania mające na celu wyeliminowanie lub ograniczenie szkodliwego oddziaływania zanieczyszczeń mikrobiologicznych na zdrowie pracowników i studentów.
The article presents the analysis of microbiological contamination ofthe air in the selected rooms located in the Main School of Fire Service. The collected material was tested using two methods: the Koch’s sedimentation method and the collision (impact) method. The test was conducted using the MAS-100 Ecoair sampler. The results obtained were compared with the hygienic standards. The measures have been proposed toeliminate or reduce the harmful effects of microbiological contamination of thestaff and students’ health.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2017, 1, 62; 105-125
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological hazards in closed facilities at sewage treatment plants
Zagrożenia mikrobiologiczne w zamkniętych obiektach oczyszczalni ścieków
Autorzy:
Polus, Michał
Mucha, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/205210.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bioaerosols
sewage treatment plant
microbiological hazards
bioaerozol
oczyszczalnia ścieków
zagrożenia mikrobiologiczne
Opis:
In this work microbiological air pollution at several commune sewage treatment plants (capacity up to 15,000 PE) was investigated. The bioreactors in all plants had a covered construction. The air samples were taken indoors as well as outdoors (both on the windward and leeward side) during different seasons. The samples were collected using the collision method. The presence of indicator organisms in the samples was determined according to the Polish Standards. Identification of individual indicators was performed on solid selective-differentiating substrates. To verify the presence of bacteria from Salmonella, Shigella, coliforms and enterococci species, the colonies observed on the MacConkey substrate were then sifted onto SS and Endo substrates. At all facilities (with one exception) the average CFU for the total number of bacteria and fungi did not exceed 1000/m3, which is the limit set by the Polish Standards for a pollution-free atmospheric air. Bacteria and fungi concentrations, observed at windward and leeward sides of all plants, were relatively low (<100 CFU/m3 and <1000 CFU/m3, respectively) and comparable. A sewage collection point had only a slight impact on the bioaerosol emission. The concentration of microorganisms in the immediate vicinity of covered reactors (aeration chambers) was rather low and remained below the limits sets by the Polish Standards at three facilities. The CFU of individual indicators, measured in rooms accessible for the personnel, was comparable to the CFU in technological rooms. However some indicators, e.g. a number of Actinomycetes, were significantly higher and reached >100 CFU/m3, which means significant air pollution. Similarly, the CFU of hemolytic bacteria had nonzero values. The only place where higher concentrations of bioaerosol were found was the centrifuge room, where digested sludge was dewatered. The number of fungi stayed below the limits there, but the amount of heterotrophic and hemolytic bacteria exceeded the limits and reached the values of ~10000 CFU/m3 and 800 CFU/m3, respectively; it means that the personnel working in this area is exposed to microbiological agents.
W pracy poddano obserwacji stopień zanieczyszczenia mikrobiologicznego w pomieszczeniach czterech oczyszczalni ścieków obsługujących poniżej 15000 RLM, posiadających obiekty socjalne i sterownie zintegrowane z obiektami technologicznymi. Ponieważ większość publikowanych dotąd prac skupiała się na dużych obiektach, autorzy starali się monitorować i oceniać stężenie mikroorganizmów w pomieszczeniach zamkniętych małych obiektów. Próbki powietrza z poszczególnych pomieszczeń (reaktor, stacja mechanicznego oczyszczania, stacja odwadniania osadu, pomieszczenia socjalne/sterownie) oraz na zewnątrz obiektów pobierano metodą zderzeniową na podłoża mikrobiologiczne przewidziane przez Polską Normę. Oznaczano wszystkie wymagane wskaźniki mikrobiologiczne. We wszystkich obiektach (z jednym wyjątkiem) średnia liczba jtk/m3 bakterii i grzybów nie przekraczała 1000/m3, a więc była poniżej limitu ustalonego w Polskich Normach dla czystego powietrza atmosferycznego. Stężenia bakterii i grzybów obserwowane na nawietrznych i zawietrznych stronach wszystkich oczyszczalni były stosunkowo niskie (<100 jtk/m3 i <1000 jtk/m3). Punkt odbioru ścieków miał tylko niewielki wpływ na emisję bioaerozolu. Stężenie mikroorganizmów w bezpośrednim sąsiedztwie reaktorów krytych (komór napowietrzania) było raczej niskie i pozostawało poniżej limitów określonych przez Polskie Normy. Wartość poszczególnych wskaźników, mierzona w pomieszczeniach dostępnych dla personelu, była porównywalna z jtk/m3 w pomieszczeniach technologicznych. Jednak niektóre wskaźniki, np. liczba promieniowców były podwyższone i przekraczały 100 jtk/m3, co oznacza znaczne zanieczyszczenie powietrza. Podobnie liczba jtk/m3 bakterii hemolitycznych była niezerowa. Jedynym miejscem, w którym znaleziono wyższe stężenia bioaerozolu, było pomieszczenie wirówki do odwadniania osadu. Liczba bakterii heterotroficznych i hemolitycznych osiągnęła wartości odpowiednio ~10000 jtk/m3 i 800 jtk/m3. Oznacza to, że personel pracujący w tym obszarze jest narażony na działanie czynników mikrobiologicznych. Obecność bakterii z rodzajów Salmonella, Shigella, bakterii grupy coli czy enterokoków stwierdzano tylko sporadycznie.
Źródło:
Archives of Environmental Protection; 2019, 45, 2; 58-65
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air Quality in a Brewery Bottling Plant
Jakość powietrza w rozlewni piwa w browarze
Autorzy:
Połednik, B.
Dudzińska, M.
Czerwiński, J.
Polednik, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818042.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
air quality
aerosols
bioaerosols
carbonyl compounds
bottling plant
jakość powietrza
aerozol
bioaerozol
związki karbonylowe
rozlewnia piwa
Opis:
Przedstawione wyniki badań dotyczą jakości powietrza w rozlewni piwa. W trakcie normalnej pracy rozlewni mierzone były stężenia masowe i koncentracje ilościowe cząstek aerozolowych, stężenia bakterii i grzybów oraz stężenia związków karbonylowych w powietrzu. Stężenia aerozoli określano w sposób ciągły metodami spektrometrii optycznej. Zanieczyszczenia biologiczne oznaczano metodą sedymentacyjną wykorzystując płytki Petriego z odpowiednimi pożywkami. Stężenia związków karbonylowych w powietrzu określano metodą pasywną używając dozymetrów Radiello. Przy oznaczaniu stężeń zanieczyszczeń biologicznych i związków karbonylowych wykonano odpowiednio dwie i trzy serie pomiarowe w dwóch miejscach rozlewni piwa. Pomimo zautomatyzowania procesu rozlewania piwa do butelek zaobserwowano okresowe znaczące wzrosty stężeń mierzonych zanieczyszczeń. Średnie stężenia masowe wszystkich mierzonych frakcji cząstek aerozolowych miały podobne wartości i wynosiły ok. 0,2 mg/3. Maksymalnie ok. 5-cio krotne wzrosty koncentracji masowych cząstek obserwowano w nieregularnych odstępach czasu. Największe koncentracje ilościowe zmierzono dla cząstek drobnych. Średnie koncentracje cząstek o wielkościach 0,3-0,5 µm i 0,5-1 µm miały odpowiednio wartości 847 i 93 cząstki/c3. W przypadku zanieczyszczeń biologicznych średnie stężenie bakterii w powietrzu w rozlewni piwa wynosiło 1441 JTK/3, a średnie stężenie grzybów 557 JTK/3. Wartości te są niższe niż proponowane dopuszczalne poziomy stężeń bakterii i grzybów w budynkach użyteczności publicznej. Średnie stężenia mierzonych związków karbonylowych również nie przekraczały wartości, które są dopuszczalnych w środowisku pracy. Oprócz formaldehydu, którego okresowe stężenia wzrastały do prawie 800 µg/3 stężenia innych związków były w zakresie akceptowalnym dla pomieszczeń przeznaczonych na pobyt ludzi. Nieco wyższe stężenia niektórych związków karbonylowych odnotowano w punkcie pomiarowym w pobliży myjni butelek. Przedstawione wyniki wskazują, że istnieje potencjalne zagrożenie dla zdrowia pracowników rozlewni piwa związane z okresowymi wzrostami stężeń mierzonych zanieczyszczeń.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 591-602
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba oceny rozkładu przestrzennego zanieczyszczeń mikrobiologicznych w powietrzu na terenie i w sąsiedztwie wybranej fermy drobiu
Attempt to estimate spatial distribution of microbial air contamination on the territory and in proximity of a selected poultry farm
Autorzy:
Plewa-Tutaj, K.
Pietras-Szewczyk, M.
Lonc, E.
Powiązania:
https://bibliotekanauki.pl/articles/237079.pdf
Data publikacji:
2014
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
ordinary kriging
spatial analysis
GIS
bioaerosol
air pollution
kriging zwyczajny
kriging prosty
analiza przestrzenna
bioaerozol
Opis:
Intensyfikacja produkcji zwierzęcej w fermach stanowi poważne zagrożenie zdrowotne, ponieważ powstający w nich bioaerozol może prowadzić do lokalnego lub rozległego zanieczyszczenia powietrza. W pracy dokonano oceny liczebności bakterii występujących w powietrzu wewnątrz i na zewnątrz fermy drobiu, jak również próby wizualizacji rozkładu przestrzennego bioaerozolu przy wykorzystaniu technik geoinformatycznych. Do analiz przestrzennych uzyskanych wyników wykorzystano oprogramowanie ArcGIS, natomiast w tworzeniu mapy rozkładu zanieczyszczeń mikrobiologicznych użyto dwóch metod interpolacji – krigingu prostego oraz krigingu zwyczajnego. Uzyskane wyniki potwierdziły słuszność poglądu o znacznej zawartości mikroorganizmów w powietrzu wewnętrznym ferm drobiu, które w postaci bioaerozolu wydostają się przez wentylatory do otoczenia. Dane mikrobiologiczne przedstawione na mapach rastrowych przy wykorzystaniu narzędzi GIS obrazują potencjalne rozprzestrzenianie się zanieczyszczeń mikrobiologicznych, a tym samym wskazują na strefy najbardziej zagrożone. Wnioski płynące z takich analiz mogą być wykorzystane do kształtowania lokalnych strategii prozdrowotnych lub architektoniczno-urbanistycznych, związanych przede wszystkim z wyborem lokalizacji terenów zabudowy mieszkaniowej.
Intensive poultry farming poses a serious health hazard as a source of bioaerosol that may lead to local and more extensive air pollution. The aim of the research was to investigate numbers of airborne bacteria inside and outside poultry houses as well as to visualize spatial distribution of bioaerosol using geoinformatic methods. ArcGIS software was used for spatial analysis of the results while interpolation methods, simple kriging and ordinary kriging, to create maps of distribution of microbial contamination. The results obtained confirmed high concentration of microorganisms in indoor air, which may spread as bioaerosol via ventilation system outdoors. Microbiological data presented on raster maps illustrate, with the use of GIS techniques, potential spread of microbial contaminants, thus, indicating the areas most at risk. Conclusions drawn from the research findings may be employed for local health or urban architectural strategy formation, mostly in relation to the choice of housing estate locations.
Źródło:
Ochrona Środowiska; 2014, 36, 2; 21-28
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary testing of a new bioaerosol sampler developed for the measurements of low and medium concentration levels of airborne bacteria and fungi
Autorzy:
Pastuszka, J.S.
Iwasiewicz, P.
Brągoszewska, E.
Powiązania:
https://bibliotekanauki.pl/articles/208027.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
aerosols
bacteria
fungi
airborne bacteria
bioaerosols
aerozole
bakterie
grzyby
bakterie unoszące się w powietrzu
bioaerozol
Opis:
A new bioaerosol sampler developed for extremely low concentration levels of airborne bacteria and fungi has been described. The results of the pilot study of the prototype of this new sampler are also presented in this paper. During the field studies the concentration levels of bacterial and fungal aerosols were obtained using simultaneously the new sampler and the reference cascade Andersen 6-stage impactor, as well as the Air Ideal sampler. Although only a preliminary study has been carried out, the obtained data indicated that the assumed designing parameters for the new sampler are suitable and guarantee high collection efficiency of this instrument.
Źródło:
Environment Protection Engineering; 2013, 39, 1; 129-138
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of microbial contamination of atmospheric air in a selected wastewater treatment plant
Ocena skażenia mikrobiologicznego powietrza atmosferycznego w wybranej oczyszczalni ścieków
Autorzy:
Paśmionka, Iwona B.
Powiązania:
https://bibliotekanauki.pl/articles/204604.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
microbial contamination
bioaerosol
sewage treatment plant
atmospheric air
skażenie mikrobiologiczne
bioaerozol
oczyszczalnia ścieków
powietrze atmosferyczne
Opis:
The aim of the research was to determine the microbiological quality of atmospheric air in the Tuchów Sewage Treatment Plant, based on the presence of mesophilic bacteria, α- and β-hemolytic bacteria, actinomycetes and fungi. Bioaerosol measurements were made at four points (raw sewage inlet, aeration chamber, purified sewage outlet and 150 m from the treatment plant, at the background point) in the period from January to December 2018. Bioaerosol samples were collected using Andersen’s 6-stage cascade impactor. The tested atmospheric air was characterized by a qualitatively and quantitatively diverse microflora. The highest amounts of all the studied groups of microorganisms were found at the raw sewage inlet, and in the case of actinomycetes, also twice in the place of biological purification. However, there were analyzes in which a higher concentration of microorganisms was observed outside the treatment plant at the control point constituting the background. This applies to bacteria and fungi. The largest source of emission of microorganisms to the atmosphere was the mechanical part of the sewage treatment plant (raw sewage inlet). The tested treatment plant may therefore contribute to the deterioration of the quality of the atmospheric air.
Celem prowadzonych badań było określenie jakości mikrobiologicznej powietrza atmosferycznego na terenie Oczyszczalni Ścieków w Tuchowie, na podstawie występowania bakterii mezofilnych, bakterii α- and β-hemolizujących, promieniowców i grzybów. Pomiary bioaerozolu wykonano w czterech punktach (wlot ścieków surowych, komora napowietrzania, wylot ścieków oczyszczonych oraz 150 m od oczyszczalni, w punkcie stanowiącym tło) w okresie od stycznia do grudnia 2018 r. Próbki bioaerozolu pobierano za pomocą 6-stopniowego impaktora kaskadowego Andersena. Badane powietrze atmosferyczne charakteryzowało się zróżnicowaną ilościowo i jakościowo mikroflorą. Najwyższe ilości wszystkich badanych grup mikroorganizmów stwierdzono przy wlocie ścieków surowych, a w przypadku promieniowców również dwukrotnie w miejscu biologicznego oczyszczania. Zdarzały się jednak analizy, w których wyższe stężenie drobnoustrojów obserwowano poza terenem oczyszczalni, w punkcie kontrolnym stanowiącym tło. Dotyczyło to bakterii i grzybów. Największym źródłem emisji mikroorganizmów do atmosfery była mechaniczna część oczyszczalni (wlot ścieków surowych). Badana oczyszczalnia może więc przyczyniać się do pogorszenia jakości powietrza atmosferycznego.
Źródło:
Archives of Environmental Protection; 2019, 45, 4; 60-67
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Powstawanie, przenoszenie i szkodliwość bioaerozoli emitowanych do powietrza atmosferycznego
Transmission and harmfulness of bioaerosols released into the air
Autorzy:
Michałkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/237345.pdf
Data publikacji:
2018
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
bioaerosol
aerosol formation
transmission of aerosols
air pollution
municipal facilities
sewage treatment
solid waste disposal
bioaerozol
powstawanie aerozoli
przenoszenie aerozoli
zanieczyszczenie powietrza
obiekty komunalne
oczyszczanie ścieków
zagospodarowanie odpadów
Opis:
Problematyka zanieczyszczenia powietrza atmosferycznego ma coraz większe znaczenie we współczesnym świecie. Wśród dyscyplin naukowych wyodrębniła się nawet aerobiologia, która jest interdyscyplinarną nauką zajmującą się badaniem mikroorganizmów i materiałów biologicznych związanych z powietrzem atmosferycznym, w tym ich uwalnianiem do atmosfery, transportem, rozprzestrzenianiem, depozycją, a także wpływem na rośliny, zwierzęta i ludzi. Do najczęściej analizowanych cząstek biologicznych w powietrzu należą bakterie, grzyby, wirusy, pyłki roślin, toksyny i alergeny, gdyż stanowią one największą część bioaerozolu znajdującego się w powietrzu. Odgrywają one szczególną rolę w wyjaśnieniu etiologii, patogenezy i mechanizmów szerzenia się wielu epidemii, w których ważną rolę odgrywa powietrze, a szczególnie bioaerozol, mogący zawierać drobnoustroje chorobotwórcze lub substancje o działaniu alergicznym i toksycznym. Mając to na uwadze, w pracy omówiono powstawanie, przenoszenie oraz szkodliwość aerozoli biologicznych, które powstają w takich obiektach komunalnych, jak oczyszczalnie ścieków czy zakłady przetwarzania odpadów. W tej grupie wyróżnia się aerozole pierwotne i wtórne, natomiast ze względu na źródło emisji mogą być one pochodzenia naturalnego i antropogenicznego. Bioaerozole składają się głównie z cząstek o wielkości od około 0,001 µm do 250 µm. Ponieważ biorą one udział w rozprzestrzenianiu się patogenów i łatwo przenikają do układu oddechowego ludzi i zwierząt, dlatego w ostatnich latach zanotowano wzrost zainteresowania tymi cząstkami. W badaniach procesu powstawania aerozoli i bioaerozoli zwraca się uwagę na mechanizm pękania pęcherzyków powietrza przemieszczających się w cieczy i wynoszenia do atmosfery bioaerozolu znajdującego się w błonie pęcherzyka i na granicy faz ciecz-powietrze. Cząstki aerozolu wynoszone do atmosfery ulegają bezpośredniej sedymentacji lub utrzymują się w powietrzu i są przenoszone przy udziale wiatru nawet na znaczne odległości. Depozycja cząstek bioaerozolu może być sucha lub mokra i wzrasta wraz z ich wielkością. Ważną rolę w procesie unoszenia i transportu niektórych bioaerozoli odgrywa kształt i obecność komór powietrznych. Podkreśla się, że potencjalnym źródłem szkodliwych bioaerozoli w powietrzu są głównie oczyszczalnie ścieków i zakłady przeróbki odpadów, w których powstają aerozole zawierające patogenne bakterie, grzyby i toksyny, a skład i wielkość danego bioaerozolu ma znaczący wpływ na jakość powietrza w ich sąsiedztwie. Ponieważ bioaerozole mogą być emitowane do otaczającego powietrza na różnych etapach oczyszczania ścieków, są one najczęściej badaną grupą czynników szkodliwych i uciążliwych występujących w sąsiedztwie tych obiektów, niestety brakuje w Polsce znowelizowanych przepisów dotyczących mikrobiologicznego zanieczyszczenia powietrza.
Nowadays, problems of atmospheric air contamination become increasingly important. Aerobiology, an interdisciplinary science has even developed to study microorganisms and biological materials related to the atmospheric air, including their release to the atmosphere, transport, distribution, deposition as well as effects they have on plants, animals and humans. The biological molecules most often analyzed in the air include bacteria, fungi, viruses, plant pollens, toxins and allergens as they constitute the largest bioaerosol fraction in the air. They play a special role in explaining etiology, pathogenesis and spread mechanisms of many epidemics where the air and specifically bioaerosol play an important role as carrying pathogens, toxins or allergens. With this specifically in mind, the paper discusses the process of formation, transmission and harmfulness of bioaerosols originating from such municipal facilities as wastewater treatment plants or solid waste processing facilities. Primary and secondary bioaerosols may be distinguished in this group, whereas based on the emission source, they may be of natural and anthropogenic origin. The bioaerosol molecules range from 0,001 μm to 250 μm. Due to their role in the spread of pathogens and ease with which they enter the respiratory system of humans or animals, a notably increased interest in these molecules could be observed during recent years. In their research on aerosol and bioaerosol formation process, authors focus on the bursting mechanism of the air bubbles passing through a liquid and release of bioaerosols located in the membrane, and on the liquid-air interface, into the atmosphere. The aerosol particles released into the atmosphere undergo direct sedimentation or remain in the air, where they are transported by wind even over considerable distances. Deposition of aerosol particles may be dry or wet and increases with the particle size. Presence of aeration chambers and their shape play an important role in the release of some bioaerosol particles into the air and their transport. It is emphasized that potential sources of harmful bioaerosols in the air include mainly municipal objects (wastewater treatment and solid waste processing plants), where aerosols carrying pathogenic bacteria, fungi and toxins are generated, while composition and concentration of a given bioaerosol has a significant impact on air quality in the vicinity of such objects. As bioaerosols may be emitted to the surrounding air at different stages of the wastewater treatment, they are the most commonly studied group of hazardous and bothersome agents occurring in the vicinity of treatment plants. Unfortunately, there is a lack of revised regulations in place regarding the microbial air contamination in Poland.
Źródło:
Ochrona Środowiska; 2018, 40, 4; 21-30
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies