Tytuł:
3D Model Studies on the Effect of Bed and Powder Type Upon Radial Static Pressure and Powder Distribution in Metallurgical Shaft Furnaces
Autorzy:
Panic, B.
Powiązania:
https://bibliotekanauki.pl/articles/351694.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
blast furnace
system descending packed bed–gas-powder
pressure
holdup powder
Opis:
The flow of gases in metallurgical shaft furnaces has a decisive influence on the course and process efficiency. Radial changes in porosity of the bed cause uneven flow of gas along the radius of the reactor, which sometimes is deliberate and intentional. However, holdup of solid particles in descending packed beds of metallurgical shaft furnaces can lead to unintentional changes in porosity of the bed along the radial reactor. Unintentional changes in porosity often disrupt the flow of gas causing poor performance of the furnace. Such disruptions of flow may occur in the blast furnace due to high level of powder content in gas caused by large amount of coal dust/powder insufflated as fuel substitute. The paper describes the model test results of radial distribution of static pressure and powder hold up within metallurgical reactor. The measurements were carried out with the use of 3D physical model of two-phase flow gas-powder in the moving (descending) packed bed. Sinter or blast furnace pellets were used as packed bed while carbon powder or iron powder were used as the powder. Wide diversity within both static pressure distribution and powder distribution along the radius of the reactor were observed once the change in the type of powder occurred.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 3; 1449-1452
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
3D Model Study of Radial Distribution of Powder Holdup in the Descending Packed Bed of Metallurgical Shaft Furnaces
Autorzy:
Panic, B.
Powiązania:
https://bibliotekanauki.pl/articles/353435.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
blast furnace
system descending packed bed–gas-powder
radial distribution of powder
Opis:
The principle of work of many metallurgical shaft furnaces is based on the flow of reaction gas through the descending packed bed composed of metallurgical materials. Hot gases flow up the shaft furnace through the column of materials, give their heat to the descending charge materials. At the same time due to their reducing nature they interact chemically, causing the reduction of oxides inside the charge. In real conditions, during the course of the process, the powder is generated, the source of which is the batch materials or it is introduced into the as part of the process procedure. The powder in the form of thin slurry is carried by the stream of flowing gas. Such multiphase flow might considerably affect the permeability of the charge due to the local holdup of powder. The holdup of solid phase in packed beds of metallurgical shaft furnaces leads to radial changes in bed porosity. Radial changes in bed porosity uneven gas flow along the radius of the reactor and negatively affect the course and efficiency of the process. The article describes the model studies on radial distribution of carbon powder holdup in the packed bed composed of metallurgical materials. The powder was divided into fractions – "static" and "dynamic". Large diversity of carbon powder distribution was observed in the function of the radius of reactor in relation to the bed type, apparent velocity of gas carrying powder and the level of bed height.
Źródło:
Archives of Metallurgy and Materials; 2018, 63, 2; 999-1002
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza skuteczności wprowadzonego systemu wsparcia wytwarzania energii elektrycznej z metanu
Analysis of the effectiveness of implemented systems of support for generating electricity from methane
Autorzy:
Kaliski, M.
Wojciechowski, R.
Szurlej, A.
Powiązania:
https://bibliotekanauki.pl/articles/282376.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
metan z pokładów węgla
zasoby metanu
system wsparcia
gospodarcze wykorzystanie metanu z kopalń
coal bed methane
methane resources
system of support
commercial utilization of methane
Opis:
W artykule dokonano przeglądu zasobów metanu z kopalń w Polsce oraz sposobów zagospodarowania tego gazu. Scharakteryzowano system wsparcia oraz przedstawiono podstawowe informacje o jego funkcjonowaniu w latach 2010-2011 r. Dokonana została uproszczona analiza ekonomiczna działającego systemu oraz przedstawiono rekomendacje. Ustawą z dnia 8 stycznia 2010 r. o zmianie ustawy - Prawo energetyczne oraz o zmianie niektórych innych ustaw wprowadzono system wsparcia w postaci świadectw pochodzenia energii elektrycznej wytworzonej w wysokosprawnej kogeneracji w jednostce opalanej metanem uwalnianym i ujmowanym przy dołowych robotach górniczych w czynnych, likwidowanych lub zlikwidowanych kopalniach węgla kamiennego. Istniejące obecnie w Polsce mechanizmy wsparcia dla produkcji energii elektrycznej z metanu, pochodzącego z kopalń węgla kamiennego są niewystarczające. Stworzony w 2010 r. system wsparcia w postaci świadectw oraz udzielanie pomocy publicznej przeznaczonej na inwestycje budowy nowych lub przystosowania istniej?cych instalacji energetycznych do wykorzystywania metanu pochodz?cego z odmetanowania kopalń węgla kamiennego nie zachęcają do zwiększenia gospodarczego wykorzystania metanu. W wyniku przeprowadzonej analizy wynika, iż należałoby: oprzeć system wsparcia na zasadach takich, jak dla systemu wsparcia odnawialnych źródeł energii (OZE), bez konieczności produkcji energii w kogeneracji, zwiększyć wartość opłaty zastępczej stosowanej w obecnym systemie wsparcia, stworzyć system wsparcia dla utylizacji i zagospodarowania metanu wentylacyjnego. Stosowane aktualnie technologie odmetanowania powodują, że metan uwalniany w trakcie robót górniczych jest w około 30% ujmowany odmetanowaniem, a w 70% usuwany na drodze wentylacyjnej. Możliwe jest zwiększenie poziomu odmetanowania z zastosowaniem obecnych technologii wydobycia węgla, czyli uj?cie 60% metanu i wyemitowanie do atmosfery 40%. Po wprowadzeniu zmian w systemie wsparcia obserwowany będzie znacz?cy efekt ekologiczny związany z zagospodarowaniem metanu.
This paper presents a review of coal mine methane resources in Poland and methods of their utilization. It characterizes the support system and presents principle information concerning the system’s functioning in the years 2010–2011. Basic economic analysis of existing systems was performed, and recommendations are presented. Based on the law dated January 8th 2010 – Energy law and changes of selected other acts certain support system based on the certificates of electrical energy origin generated in the highly efficient cogeneration in the unit fired with methane released and captured during underground mining works in operating, under liquidation or already closed hard coal mines was introduced. The mechanisms to support the production of electrical energy from coal mine methane already existing in Poland are not sufficient. The support system created in 2010 using certificates and public support meant for the construction of new, or adjustments to existing, energy installations to utilize methane coming from the drainage systems of hard coal mines fail to encourage increasing economical utilization of coal mine methane. The conclusions from the above analysis suggest that it is recommendable to: have existing support systems rely on the same rules as for the system of renewable sources of energy, without the necessity to produce energy in cogeneration, increase the supplementary fee used in the present support system, create a support system for the capturing and utilization of ventilation air methane. The technologies presently used to drain coal mine methane released during mining exploitation enable the capture of only 30% of the gas. The remaining 70% is released into the atmosphere. It is possible to increase the efficiency of methane drainage up to as much as 60% when implementing the latest drainage technologies mitigating methane emissions down to 40%. The introduction of the suggested changes in the support system should result in a significant ecological effect from coal mine methane’s economical utilization.
Źródło:
Polityka Energetyczna; 2012, 15, 4; 57-69
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Całoroczne oczyszczanie ścieków z przetwórstwa owocowo-warzywnego w złożu hydrofitowym
Annual treatment of wastewater from small fruit and vegetable processing plant in the reed bed system with vertical flow
Autorzy:
Soroko, M.
Powiązania:
https://bibliotekanauki.pl/articles/339528.pdf
Data publikacji:
2011
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
BZT5
ChZT
substancja organiczna
ścieki z przetwórni owocowo-warzywnej
złoże hydrofitowe
BOD5
COD
organic matter
reed bed system
wastewater from fruit and vegetable processing plant
Opis:
Badano całoroczną skuteczność oczyszczania ściekow z małej przetworni owocowo-warzywnej w piaskowym złożu hydrofitowym z przepływem pionowym, porośniętym trzciną. W ściekach tych, ubogich w azot i fosfor, głównym zanieczyszczeniem była substancja organiczna. Jej zawartość, wyrażona w BZT5 i ChZT, wynosiła odpowiednio 1 500-11 800 g O2·m-³ i 2 000-17 000 g O2·m-³. Skuteczność jej usuwania zależała w dużym stopniu od temperatury złoża. W temperaturze powyżej 5°C znosiło ono zadawalająco obciążenia wyrażone w BZT5 do ok. 90 g O2·m-²·d-¹ i wyrażone w ChZT do ok. 130 g O2·m-²·d-¹. W temperaturze 3.5°C dopuszczalne okazały się obciążenia złoża wyrażone w BZT5 i ChZT odpowiednio do ok. 50 g O2· m-²·d-¹ i do ok. 70 g O2·m-²·d-¹. W temperaturze złoża 1-2°C dopuszczalne obciążenie wyrażone w ChZT wyniosło ok. 30 g O2 ·m-²·d-¹.
Annual efficiency was examined of the treatment of wastewater from small fruit and vegetable processing plant in a sandy hydrophyte bed with vertical flow overgrown by reed. The main pollutant in this wastewater poor in nitrogen and phosphorus was organic matter. Its concentration expressed in BOD5 and COD amounted to 1500–11 800 g O2·m-³ and 2000–17 000 g O2·m-³, respectively. The efficiency of its elimination depended to a large extent on reed bed temperature. At temperatures exceeding 5°C the reed bed satisfactorily withstood the load 90 g O2·m-²·d-¹ and about 130 g O2·m-²·d-¹ measured in BOD5 and COD, respectively. At temperatures of 3-5°C permissible organic matter loads were about 50 g O2·m-²·d-¹ and about 70 g O2·m-²·d-¹, respectively and at outflow temperatures of 1-2°C - 30 g O2·m-²·d-¹ expressed in COD.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2011, 11, 1; 289-298
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Co-variability of bars in a multi-bar nearshore zone determined with canonical correlation analysis (CCA)
Autorzy:
Różyński, G.
Powiązania:
https://bibliotekanauki.pl/articles/241073.pdf
Data publikacji:
2001
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
co-variability
bed features
nearshore zone
multi-bar system
canonical correlation analysis
CCA
Baltic Sea
Opis:
Nearshore bed variations of the southem Baltic shore were investigated with the aim of detecting co-variability among bed forms of a multi-bar system. The studied area is located at IBW PAN Coastal Research Station at Lubiatowo. The beach consists of fine sand of median grain equal to 0.22 mm, is mildly sloping and boasts multiple (usually 4) bars, which is typical for the coast in the southem Baltic. Data on bed topography were collected along 27 lines, equally spanned every 100 m, since 1987 to 1999, usually twice a year. Fairly high alongshore bed homogeneity made it possible to choose one representative profile for which the CCA method was employed. The method demonstrated considerable potential for detecting co-variability of bed features in the nearshore zone. The results show that some 80% of variability in the region of the offshore slope of the outermost bar can be attributed to variations of Dean equilibrium profiles. The portion of variability of the two innermost bars due to variations of equilibrium profiles equals 40%. Horizontal counter-movements of outer and inner bars can be responsible for same 20%. The remaining 40% should be related to highly variable short time scale phenomena like breakers and wave driven currents in the vicinity of inner bars.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2001, 48, 2; 91-106
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detekcja nieszczelności kotła fluidalnego z użyciem modeli rozmyto-neuronowych
Approach to boiler leak detection with fuzzy neural models
Autorzy:
Szadkowski, B.
Jankowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/257517.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
detekcja awarii
systemy rozmyto-neuronowe
kocioł fluidalny
modelowanie
detection of outage
fuzzy-neural system
fluidised bed boiler
modelling
Opis:
Zreferowano badania modelowe nad detekcją nieszczelności kotłów fluidalnych z wykorzystaniem danych z archiwum. Modelowanie prowadzono w przyborniku Fuzzy Logic pakietu Matlab. Omówiono dwa podejścia do rozwiązania problemu. W pierwszym - opracowano modele rozmyto-neuronowe typu Takagi-Sugeno-Kanga (TSK) 4 zmiennych procesowych o dużej wrażliwości na przeciek. Uśrednione residua tych zmiennych, w przesuwnym oknie czasowym, pozwoliły wykryć 7 z 8 rozważanych przypadków nieszczelności. Oceniono długość okna i uzyskane wyprzedzenie detekcji względem wyłączenia bloku. Następnie opracowano i przetestowano model awarii o binarnym wyjściu. Równoległe wykorzystanie opracowanych modeli pozwoliło na wykrycie z kilkudniowym wyprzedzeniem wszystkich analizowanych awarii, potwierdzając przydatność modeli TSK w ważnym zadaniu eksploatacyjnym. Wskazano dalsze kierunki prac.
The research results into leak detection in a fluidised bed boiler are presented. The studies took advantage of the historical data from DCS in the professional power plant. Models of neuro-fuzzy Takagi-Sugeno-Kanga (TSK) type were built and tested in the Fuzzy Toolbox of Matlab. The roots of boiler outage (in water-steam pressure system and aside from this system) are indicated. The two approaches to leak detection task are described. In the first, the models of the 4 process variables sensitive to leakage were built. The residues of these models were evaluated in a moving time window. The length of the time window and the advance of leakage detection are discussed. Next, the model the TSK of the boiler faults with binary output was built and tested. Training data was collected for 3 cases of raised outage (models output - 1) and the normal work of installation (models output - 0). The parallel usage of proposed TSK models provided a successful detection of all studied fault cases a few days in advance. This has confirmed the suitability of the fuzzy neural models in an important exploitation task.
Źródło:
Problemy Eksploatacji; 2011, 2; 181-188
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność oczyszczania ścieków bytowo-gospodarczych w oczyszczalniach gruntowo-roślinnych i glebowo-roślinnych
The efficiency of domestic sewage tretment in ground-plant and soil-plant treatment units
Autorzy:
Czyżyk, F.
Pulikowski, K.
Strzelczyk, M.
Pawęska, K.
Powiązania:
https://bibliotekanauki.pl/articles/338757.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczalnie glebowo-roślinne
oczyszczanie ścieków
reed bed system
soil-plant treatment
wastewater treatment
Opis:
Celem badań prezentowanych w pracy było rozpoznanie zmian efektywności oczyszczania ścieków bytowych w oczyszczalniach gruntowo-roślinnych i glebowo-roślinnych w zależności od czasu i warunków ich eksploatacji. W pracy przedstawiono wyniki badań skuteczności oczyszczania ścieków w złożach gruntowo-trzcinowych, zbudowanych wg systemu Kickutha, oraz oczyszczalni glebowo-roślinnej w początkowym okresie eksploatacji (na 4 obiektach) i po 15 latach (na 2 obiektach). Zaskakujące były zdecydowanie różniące się wyniki, uzyskane w pierwszych latach eksploatacji, z dwóch podobnych złóż gruntowo-trzcinowych, których eksploatację rozpoczęto w tym samym roku. Na jednym skuteczność oczyszczania zwiększała się z upływem czasu, a na drugim wystąpiły objawy braku tlenu w złożu i słabej nitryfikacji azotu, co przejawiało się dużym stężeniem N-NH4 w odpływach z oczyszczalni. Przyczyną tego była błędna lokalizacja oczyszczalni - w miejscu silnie zacienionym, co wpłynęło na bardzo słaby rozwój trzciny i jej systemu korzeniowego, a tym samym na słabe napowietrzanie złoża. Z upływem lat eksploatacji pogarszała się przepuszczalność złóż dwóch badanych oczyszczalni gruntowo-trzcinowych i wystąpiło ich zakolmatowanie, powodowane głównie niedostatecznym oczyszczaniem wstępnym doprowadzanych ścieków. Stwierdzono znacznie wyższy stopień oczyszczania ścieków w oczyszczalni glebowo-roślinnej, zarówno w początkowym okresie eksploatacji, jak i po 15 latach. Uzyskane zmniejszenie głównych wskaźników zanieczyszczenia po 15 latach eksploatacji gruntowo-trzcinowych było następujące (w %): Nog - 47, Pog - 63, BZT5 - 93, ChZTCr - 81, natomiast na oczyszczalni glebowo-roślinnej: Nog - 84, Pog - 99, BZT5 - 95, ChZTCr - 74.
The aim of this study was to trace changes in the efficiency of domestic sewage treatment in soilplant and ground-plant systems in relation to the time and conditions of use. The paper presents results of testing the effectiveness of sewage treatment in ground reed beds constructed according to Kickuth system and in soil-plant treatment units, in the beginning of utilization period (in 4 objects) and after 15 years (in 2 objects). Surprising were the definitely different results obtained during the first years of utilization in two similar reed beds, which started operating in the same year. In one, the efficiency of treatment increased with time and in the other the symptoms of oxygen deficit and weak nitrification were observed in the bed which manifested itself in high N-NH4 concentrations in the outflow from the treatment unit. The reason was in faulty location of the treatment unit in an intensely shaded place resulting in poor development of reed and its root-rhizome system and, consequently, in poor aeration of the bed. In the two examined ground reed treatment units, the beds lost their permeability and became silted with time due mainly to insufficient primary sewage treatment. The soil-plant treatment unit showed considerably higher degree of sewage purification, both during the initial period of utilization and after 15 years. In ground reed beds, after 15 years of their utilization, the reduction of main pollutants was (in %): Ntot - 47, P - 63, BOD - 93, CODCr - 81, whereas in soil-plant treatment units it was: Ntot - 84, P - 99, BOD - 95, CODCr - 74.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2012, 12, 4; 97-108
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gospodarcze wykorzystanie metanu z pokładów węgla JSW S.A. w instalacjach energetycznych
Economical utilization of coal-bed methane from Jastrzębie Coal Company in cogeneration power system
Autorzy:
Tor, A.
Gatnar, K.
Powiązania:
https://bibliotekanauki.pl/articles/350591.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
metan pokładów węgla
silniki gazowe
skojarzony układ energetyczny
coal bed methane
gas engines
cogeneration power system
Opis:
Artykuł przedstawia ujęcie i wykorzystanie metanu z obszaru górniczego JSW S.A. w latach 2000-2004. Prezentuje strukturę wykorzystania w roku 2004 oraz zrealizowane inwestycje energetyczne w latach 1997-2004, inwestycje w toku i planowane do realizacji w latach 2006-2007 (realizowane samodzielnie przez JSW S.A. i wspólnie z SEJ S.A.). Omówiono skojarzony układ energetyczny w kopalni "Krupiński" oraz układ energetyczno-chłodniczy w KWK "Pniówek" w aspekcie technicznym, ekonomicznym i ekologicznym ograniczenia emisji metanu do atmosfery.
Paper presents the resources of coal bed methane in the region of Jastrzębie Coal Company (JSW SA) coming from both active and abandoned coal mines. It is also presented how the gas is being used in heat and power plants grouped in Energy Company Jastrzębie (SEJ SA) and in new cogeneration and trigeneration installations with gas engines at Suszec and Pniówek plants. In the summary the role of combined production plants for energy delivery to coal mines is discussed as well as further possibilities of coalbed methane utilization is plants based on gas engines are presented.
Źródło:
Górnictwo i Geoinżynieria; 2005, 29, 4; 177-181
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Konwersja kotła pyłowego węglowego OB230p na kocioł fluidalny biomasowy BFB220 oraz przystosowanie turbiny TG5 do pracy w układzie kogeneracyjnym
Autorzy:
Roszak, Waldemar
Powiązania:
https://bibliotekanauki.pl/articles/2096859.pdf
Data publikacji:
2021
Wydawca:
Nowa Energia
Tematy:
technologie
kocioł pyłowy
kocioł węglowy
kocioł fluidalny
kocioł biomasy
układ kogeneracyjny
technologies
dust boiler
coal boiler
fluidized bed boiler
biomass boiler
cogeneration system
Opis:
ZE PAK S.A. w 2020 r. zlecił firmie Valmet Technologies realizację w formule „pod klucz” kontraktu na zaprojektowanie i wykonanie przebudowy kotła węglowego K-7 w Elektrowni Konin na kocioł fluidalny pracujący w technologii BFB. W ramach prac modernizacyjnych zlecono również firmie Etos Energy przystosowanie turbiny TG-5 (typu TK50) do pracy w kogeneracji. Kocioł K7 z turbogeneratorem TG5 i instalacjami pomocniczymi stanowi nowy blok nr 5.
Źródło:
Nowa Energia; 2022, 2; 56-60
1899-0886
Pojawia się w:
Nowa Energia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical Model of Gas, Powder and Bed Flow in Metallurgical Shaft Furnaces
Autorzy:
Panic, B.
Powiązania:
https://bibliotekanauki.pl/articles/353174.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mathematical modeling
metallurgical shaft furnace
system: descending packed bed - gas - powder
resistance of gas flow
bed suspension
Opis:
This paper presents the second phase of model investigations. In the first phase research into flow for the system “gas transporting powder - moving packed bed” was conducted in the physical modeling. The influence of bed, powder and gas parameters on values of interaction forces and phenomena occurring in investigated system was defined. The article discusses the successive stage of investigations into gas flow carrying the powder through the descending packed bed. The research was performed with the application of mathematical modeling after tests with a physical model in use had been accomplished. The elaborated mathematical model was used to calculate resistance values of gas flow carrying the powder through the descending packed bed, masses of ‘static’ and ‘dynamic’ powders as well as total mass of powder holdup in the bed. Then the verification of the model was done comparing the obtained results with those from the physical model.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 1; 227-232
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena potencjału zasobowego CBM (coal bed methane) oraz możliwości występowania akumulacji gazu ziemnego typu tight w formacjach piaskowcowo-mułowcowych GZW
Assessment of the unitary resource potential of coal bed methane and the possibilities of tight gas accumulations occurrence, in sandstone-mudstone formations of the Upper Silesian Coal Basin
Autorzy:
Słoczyński, T.
Drozd, A.
Sowiżdżał, K.
Powiązania:
https://bibliotekanauki.pl/articles/1835305.pdf
Data publikacji:
2017
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
potencjał zasobowy
formacja mułowcowo-piaszczysta
niecka GZW
złoże niekonwencjonalne
system naftowy
resource potential of coal bed methane
Upper Silesian Coal Basin
unconventional tight reservoirs
petroleum systems
Opis:
W artykule przedstawiono wyniki obliczeń jednostkowego potencjału zasobowego metanu w pokładach węgla kamiennego niecki GZW (coalbed methane) oraz ocenę możliwości występowania akumulacji gazu ziemnego typu tight w formacjach mułowcowopiaszczystych zalegających pomiędzy pokładami węgla. Zadanie zrealizowano, wykorzystując metodę dynamicznego przestrzennego modelowania 4D systemów naftowych przy użyciu oprogramowania PetroMod firmy Schlumberger. Modelowaniu poddano fragment karbońskiego wypełnienia niecki GZW o wymiarach 2,5 2,5 km, zlokalizowanego w jej południowo-zachodniej części. W ramach realizacji pracy skonstruowano przestrzenny dynamiczny model karbońskiego systemu naftowego, który był symulowany przy założeniach różnych scenariuszy ewolucji basenu sedymentacyjnego. Do budowy i kalibracji modeli wykorzystano dane dostępne w materiałach publikowanych, dane otworowe oraz wyniki badań laboratoryjnych próbek utworów karbońskich z odwiertów Jastrzębie-7b i Jastrzębie-8b, a także węgli kamiennych z KWK Zofiówka. W wyniku przeprowadzonych prac oszacowano jednostkowy potencjał zasobowy metanu w pokładach węgla kamiennego niecki GZW, wykazano zależność jego wielkości od typów węgli oraz przebiegu ewolucji basenu sedymentacyjnego niecki, a także oceniono możliwości występowania niekonwencjonalnych akumulacji typu tight w formacjach mułowcowo-piaszczystych.
The article presents the results of the unitary resource potential assessment of coal bed methane of the Upper Silesian Coal Basin (Coal Bed Methane) and an evaluation of the possibility of natural gas occurrences in tight, sandy mudstone formations interbedding coal seams. The task was carried out using the method of 4D dynamic petroleum systems modeling using the PetroMod software. Modeling tasks were carried for Carboniferous strata in the south-western part of the Upper Silesian Coal Basin, in the area of the Zofiówka coal mine. A spatial dynamic model (4D) of the Carboniferous petroleum system was developed, which was subsequently simulated assuming different scenarios for the evolution of the sedimentary basin. For model construction and calibration purposes, several data sources were used: well data of Jastrzębie-7B and Jastrzębie-8B wells, results of laboratory measurements of coal and rock samples from Zofiówka coal mine as well as published data. As a result, unitary estimation of the resource potential of coal bed methane of the Upper Silesian Coal Basin was presented, as well as its dependence upon the geological conditions of coal seams burial depths. The possibilities of the occurrence of unconventional accumulation of tight gas in sandy mudstone formations interbedding coal seams, were also indicated.
Źródło:
Nafta-Gaz; 2017, 73, 10; 739-749
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stanu systemu umocnień dna w rejonie nabrzeży portowych
The assessment of a seabed protection system near a quay wall
Autorzy:
Abramowicz-Gerigk, T.
Burciu, Z.
Powiązania:
https://bibliotekanauki.pl/articles/257895.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
manewry portowe
umocnienie dna
ocena stanu systemu
harbour manoeuvres
sea bed protection
assessment of system state
Opis:
W artykule przedstawiono koncepcję oceny stanu umocnień dna w basenach portowych, w rejonie cumowania statków wykorzystujących własne urządzenia napędowe i sterujące, w szczególności promów i statków ro-ro. Omówiono czynniki wpływające na stan systemu. Do opisu procesu degradacji systemu umocnień dna zaproponowano proces gamma (Xt)t≥ 0, który może być określony na podstawie fizycznych charakterystyk degradacji systemu. Podano przykład badań symulacyjnych i obliczeń numerycznych umożliwiających przewidywanie oddziaływania strumieni zaśrubowych statku na dno i nabrzeże podczas manewrów.
This paper presents a concept for the assessment of the state of a seabed protection system in docks, in the area of self-berthing operations, performed by ferries and ro-ro vessels. The factors influencing the system state are described. The Gamma process (Xt)t≥ 0 has been proposed do describe the process of degradation of seabed protection systems, which can be described by physical characteristics. The example of ship motion simulation and CFD calculation were presented to demonstrate the possibility of predicting the influence of a propeller jet on seabed protection and quay wall during manoeuvres.
Źródło:
Problemy Eksploatacji; 2011, 1; 7-16
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczalnie przydomowe a zagrożenie środowiska wodnego
Water environment pollution and building on-site waste-water treatment systems
Autorzy:
Eymontt, A.
Rogulski, B.
Powiązania:
https://bibliotekanauki.pl/articles/239330.pdf
Data publikacji:
2006
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
ścieki
oczyszczalnia przydomowa
złoże
rozsączanie
wastewater
on-site system
bed
drainage
Opis:
Oczyszczalnie przydomowe ścieków bytowych są od kilkunastu lat wprowadzane na tereny wiejskie jako rozwiązanie alternatywne w stosunku do zbiorczych systemów oczyszczania ścieków. W wielu gminach, korzystając z liberalnych przepisów dotyczących ich budowy i eksploatacji, zastosowano rozwiązania grupowe, po kilkaset oczyszczalni w jednej gminie lub wsi, co stwarza zagrożenie dla środowiska wodnego i glebowego przy niewielkiej, wymaganej przepisami redukcji zanieczyszczeń w odprowadzanych, oczyszczonych ściekach. Dotychczasowe wyniki badań jakości odprowadzanych ścieków wykazały, że równolegle należy badać jakość wód gruntowych i podziemnych wokół oczyszczalni przydomowych, a szczególnie grup oczyszczalni, co pozwoli na określenie zakresu ich zastosowania. Na terenach wiejskich znajduje się większość zasobów wodnych i należy przeciwdziałać ich zanieczyszczaniu. W ocenie badanych oczyszczalni mogą być szczególnie przydatne normy i projekty tematycznych norm europejskich.
On-site waste-water treatment systems have been implemented on rural areas for several years as alternative solution to the typical canalization. In many gminas, availing of the liberal building and exploitation regulations treated about the on-site systems have been implemented grouped such a systems with a few hundred in one gmina or village. It causes great pollution water and soil environment, when pollution reduction level in treated waste-water, according to the existing regulations is very low. Up till now, measurement results of the quality of outlet waste-water from on-site systems showed us, that parallel should be measured quality of the surface and underground waters from around on-site systems, particularly groups of the on-site systems, what allows for the evaluation of the future scope of these systems building. It must be underlined, that on the rural areas are the greatest part of the water magazines, and we must prevent water pollution. In evaluation of the on-site systems will be very helpful European Standards and Standards Projects from that area.
Źródło:
Problemy Inżynierii Rolniczej; 2006, R. 14, nr 2, 2; 107-116
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczalnie ścieków z małej przetwórni owocowo-warzywnej w złożach gruntowo-roślinnych z przepływem pionowym
Treatment of wastewaters from small fruit and vegetable processing plant in the reed bed systems with vertical flow
Autorzy:
Soroko, M.
Powiązania:
https://bibliotekanauki.pl/articles/338470.pdf
Data publikacji:
2007
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
BZT5
ChZT
oczyszczalnia hydrofitowa
substancja organiczna
ścieki z przetwórni owocowo-warzywnej
BOD5
COD
organic matter
reed bed system
wastewater from fruit and vegetable processing plant
Opis:
Badano skuteczność oczyszczania ścieków z małej przetwórni owocowo-warzywnej w 4 złożach gruntowo-roślinnych z przepływem pionowym, porośniętych trzciną. W ściekach tych, ubogich w azot i fosfor, głównym zanieczyszczeniem była substancja organiczna. Jej zawartość, wyrażona w BZT5 i ChZT, wynosiła odpowiednio 1 500-8 000 i 2 000-13 000 g O2·m-³. Największą skuteczność oczyszczania osiągnięto na wpracowanym złożu piaskowym, znoszącym zadowalająco obciążenia tą substancją wyrażone w BZT5 do ok. 90 g O2·m-²·d-¹ i w ChZT - do ok. 110 g O2·m-²·d-¹. W przypadku wpracowującego się złoża piaskowo-żwirowego, wskaźniki te wyniosły tylko około 50 i 70 g O2·m-²·d-¹. Zastosowanie na takim samym złożu wzbogacania ścieków azotem, zmniejszającego stosunek BZT5 : N z około 200 do 70 powodowało zwiększenie wartości tych wskaźników odpowiednio do około 70 i 90 g O2·m-²·d-¹. Wyniki te osiągnięto, gdy temperatura odpływów ze złóż była większa niż 5°C. W przypadku temperatury 4-4,5°C wystarczającą skuteczność zapewniło zmniejszenie obciążenia złóż wyrażonego w BZT5 do ok. 50 g O2·m-²·d-¹ i w ChZT - do ok. 70 g O2·m-²·d-¹.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2007, T. 7, z. 2b; 177-184
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary tests on an integrated laboratory control system for the feeding system of a dual - fuel diesel engine and its load
Autorzy:
Wierzbicki, S.
Śmieja, M.
Piętak, A.
Powiązania:
https://bibliotekanauki.pl/articles/244419.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
CI engine
engine test bed
CR system
control system
combustion engine tests
Opis:
Comprehensive testing of diesel engines currently requires not only a control system for the feeding system of the engine, but also a system ensuring precise control of its load and providing constant measurement conditions. Additionally, it is necessary during the tests to record a considerable number of operating parameters of both the engine and the loading system. The currently available stands for diesel engine tests, the so-called “engine test beds”, are standardly-equipped with special systems controlled using computer applications to ensure the maintenance of the assumed engine operation parameters. For compression-ignition engines, this most often takes place by control of the accelerator pedal position. In this solution, the engine is controlled by the engine controller, which controls the fuel charge based on the measurement of the rotational speed and the accelerator pedal position depending on the assumed control algorithm. The shortcoming of this solution is no possibility of controlling selected fuel feeding parameters, such as fuel pressure or the injection advance angle. This paper presents preliminary tests on an integrated control system for both engine load and the parameters of fuel fed to a compression-ignition engine. The developed control system enables engine test bed control, which, depending on the measurement variant, ensures the maintenance of a constant rotational speed or a constant engine load as well as control of the Common Rail system actuators.
Źródło:
Journal of KONES; 2013, 20, 2; 393-399
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies