Wyszukujesz frazę "beam-to-column joint" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Temperature Distribution in a Steel Beam-to-Column Joint when Exposed to Fire. Part 2: Flange-Plates and Web-Cleats Joint
Autorzy:
Maślak, M.
Suchodoła, M.
Woźniczka, P.
Powiązania:
https://bibliotekanauki.pl/articles/104693.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
beam-to-column joint
flange-plates joint
web-cleats joint
temperature distribution
section factor
numerical simulation
Opis:
In the second part of this paper the temperature distribution is analysed for a thermally uninsulated steel beam-to-column flange-plates and web-cleats joint after 15 minutes of its exposure to a fully developed fire. Two types of such a joint are considered separately, firstly the pure steel connection with a beam and a column evenly heated on all four sides and then the analogous one, but with a massive reinforced concrete floor slab lying on the upper beam flange. In the latter case the joint beam is heated only on three sides. In addition, in each of the analysed joint the beams of two sizes are analysed independently for comparative purposes. Those that are made of the bigger I-section have a more slender web, while the smaller ones are more stocky. However, the smaller I-section heats faster than the bigger one because the section factor calculated for it has a greater value. In general, it can be concluded that in all the joints considered by the authors the steel temperature turned out to be much lower than that measured outside these joints. Moreover, a significant difference is observed in the temperature values identified in the beam web and in the beam flanges. Finally, the temperature distribution obtained from a numerical simulation and identified in the selected cross-sections of the joint beam in the case of a joint with adjacent floor slab is referred to the analogous distribution recommended for use in such circumstances in the standard EN 1993-1-2.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 103-114
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania doświadczalne ramy portalowej do celów walidacji modelu MES doczołowego połączenia belki ze słupem
Experimental study of the portal frame for the validation of FEM model of beam to column joint
Autorzy:
Ostrowski, K.
Kozłowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/105009.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
zdolność do obrotu
walidacja hierarchiczna
analiza MES
rama portalowa
połączenie słup-belka
rotation capacity
FEM analysis
hierarchical validation
portal frame
beam to column joint
Opis:
W artykule przedstawiono wyniki badań czwartego etapu walidacji hierarchicznej modeli MES, wykonanego w celu analizy zdolności do obrotu węzłów stalowych. Program badawczy obejmuje wykonanie testów laboratoryjnych dwóch ram portalowych wykonanych z kształtowników walcowanych oraz porównanie wyników testów z wynikami analiz numerycznych wykonanych metodą elementów skończonych przy użyciu oprogramowania Ansys. Jako kryterium porównawcze przyjęto krzywą odpowiedzi kąta obrotu połączenia rygla ze słupem, którą w teście laboratoryjnym wyznaczono za pomocą zestawu inklinometrów. Dokonano oceny wpływu użebrowania w słupie na zdolność do obrotu węzłów. Układ ramowy bez żeber usztywniających wykonano z kształtowników HEB 260, natomiast układ ramowy z żebrami usztywniającymi wykonano z kształtowników HEA 240. Elementy składowe układów ramowych wykonano ze stali S235 oraz S355. Na elementy złączne zastosowano śruby wysokiej wytrzymałości klasy 10.9 według normy ISO 4014.
The laboratory test results of 4th stage hierarchical validation of FEM model created for analysis of steel joint’s rotation capacity have been presented in the paper. The research program contains performing laboratory tests of two portal frame made of hot rolled profiles and comparison of tests results with results obtained in numerical analysis using FEM by ANSYS software. As a comparative criterion was assumed the response curve of beam to column joint’s rotation angle, which was determined in laboratory test by set of inclinometers. An assessment was done for the impact of ribbing the column for joint rotation capacity. Frame system without stiffening ribs was made of HEB260, while the system with stiffening ribs was made of HEA240. The components of frame systems were made of steel grade S235 and S355. As fixing elements have been used high strength bolts class 10.9 according to ISO 4014.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 3/I; 437-446
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite element modelling of the behaviour of a certain class of composite steel-concrete beam-to-column joints
Skończenie-elementowe modelowanie zachowania się pewnej klasy węzłów zespolonych stalowo-betonowych w połączeniach rygli ze słupami
Autorzy:
Giżejowski, M. A.
Barcewicz, W.
Salah, W.
Powiązania:
https://bibliotekanauki.pl/articles/231473.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analiza nieliniowa
metoda elementów skończonych
zachowanie niesprężyste
węzeł zespolony stalowo-betonowy
połączenie rygiel-słup
composite steel-concrete joint
finite element model
nonlinear analysis
inelastic behaviour
beam-to-column joint
Opis:
Beam-to-column end-plate joints can be classified as rigid (fully restrained), semi-rigid (partially restrained) or pinned, depending on their type, configuration and the connector arrangement. Fully restrained joints are needed for rigid frames in which there is assumed that the frame joints have sufficient rigidity to maintain - under the service state - the angles between the intersecting members, ensuring the full moment transfer. In contrast in semi-continuous frames, partially restrained joints are characterized by relative rotations occurring between the intersecting members so that the bending moment can only be transferred partially. In recent years, the idea of using partially restrained, unstiffened joints in building structures has gained momentum since this idea appears to be more practical and economical. Semi-continuous frames can resist actions by the bending moment transfer in partially restrained joints, allowing in the same time for a certain degree of rotation that enhances the overall ductile performance of these structures. One of the effective ways that affects ductility of end-plate beam-to-column joints is to use thinner end-plates than those used nowadays in practical applications. In the current study, a certain class of steel-concrete composite joints is examined in which the thickness of end-plates is to be equivalent to approximately 40-60% of the bolt diameter used in all the composite joints investigated in the considered joint class. This paper is an extension of the authors' earlier investigation on numerical modelling of the behaviour of steel frame joints. The aim of current investigations is to develop as simple as possible and yet reliable three-dimensional (3D) FE model of the composite joint behaviour that is capable of capturing the important factors controlling the performance of steel-concrete end-plate joints in which the end-plate thickness is chosen to be lesser than that used nowadays in conventional joint detailing. A 3D FE model constructed for composite joints of the considered joint class is reported in this paper and numerical' simulations using the ABAQUS computer code are validated against experimental investigations conducted at the Warsaw University of Technology. Comparison between the nonlinear FE analysis and full scale experimental results of the considered class of composite joints is presented which conclusively allows for the accuracy assessment of the modelling technique developed. Comparison between the FE results and test data shows a reasonable agreement between the numerical FE model developed and physical model of experimentally examined joint specimens. Finally, practical conclusions for engineering applications are drawn.
Węzły w konstrukcjach ramowych można sklasyfikować jako sztywne (o pełnej nośności), podatne (o niepełnej nośności) lub nominalnie przegubowe, w zależności od ich typu, konfiguracji i rozmieszczenia łączników. Węzły o pełnej nośności są wymagane dla ram sztywnych, w których założono, że węzły zapewniają pełne przeniesienie momentów zginających z rygli na słupy. Natomiast w ramach z węzłami podatnymi o niepełnej nośności, węzły są charakteryzowane przez względne obroty pojawiające się pomiędzy łączonymi elementami tak, że moment zginający może być przeniesiony tylko częściowo. W ostatnich latach, idea wykorzystania bezżebrowych węzłów podatnych zyskuje coraz większe zastosowanie w praktyce inżynierskiej. Ramy niepełnociągłe mogą przeciwstawiać się oddziaływaniom dzięki węzłom podatnym o niepełnej nośności, które przenoszą momenty zginające przy jednoczesnym pojawieniu się lokalnego obrotu elementów przerwanych w węźle. Jednym z efektywnych sposobów zwiększających ciągliwość węzłów typu rygiel-słup z blachami czołowymi jest zastosowanie blach o grubości mniejszej niż stosowana obecnie w praktyce inżynierskiej. W niniejszej pracy, poddano analizie grupę węzłów zespolonych stalowo-betonowych, w których grubość blachy czołowej stanowi około 40-60% średnicy śrub. Praca stanowi rozwinięcie zagadnień opracowanych przez autorów w powoływanych pracach wcześniejszych i dotyczących numerycznego modelowania zachowania się węzłów stalowych w konstrukcjach ramowych. Celem rozważań jest znalezienie prostego i jednocześnie wystarczająco dokładnego modelu 3D zachowania się węzła zespolonego, uwzględniąjącego najistotniejsze czynniki wpływające na zachowanie się stalowo-betonowych węzłów doczołowych z blachami o grubościach mniejszych niż stosowane w rozwiązaniach konwencjonalnych. Przedstawiono model 3D skonstruowany dla rozważanego typu węzłów zespolonych, przy wykorzystaniu systemu ABAQUS oraz porównano wyniki symulacji numerycznych z wynikami badań doświadczalnych przeprowadzonych w Politechnice Warszawskiej. Porównanie wyników nieliniowego modelu skończenie-elementowego z wynikami badań doświadczalnych węzłów zespolonych w skali technicznej, świadczy o poprawności przyjętej techniki modelowania, jak również o zadowalającej zgodności modelu numerycznego z modelem fizycznym elementów badanych doświadczalnie. Na zakończenie podano praktyczne uwagi dotyczące innowacyjnego kształtowania i projektowania rozpatrywanej klasy węzłów zespolonych.
Źródło:
Archives of Civil Engineering; 2010, 56, 1; 19-56
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature Distribution in a Steel Beam-to-Column Joint when Exposed to Fire. Part 1: End-Plate Joint
Autorzy:
Maślak, M.
Suchodoła, M.
Woźniczka, P.
Powiązania:
https://bibliotekanauki.pl/articles/105584.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
beam-to-column steel end-plate joint
fire
temperature distribution
joint components
numerical simulation
Opis:
Temperature distribution usually observed in steel beam-to-column end-plate joint after 15 minutes of its standard fire exposure is presented and discussed in detail. Two types of joints are analysed for comparative purposes. The first one is a pure steel connection while the other is covered by a reinforced concrete slab. Numerical simulation of the considered joint heating scenario was performed using the 3D model in the ANSYS environment. Some results were additionally verified by simpler calculations carried out on 2D models using the SAFIR computer program. It is emphasized that due to the local accumulation of many massive steel plates the representative temperature values identified in particular joint components are significantly lower than those which at the same time are measured in beam and column outside the connection. This means that the classic assumption of even temperature over the entire length of all the structural elements of a frame load-bearing structure exposed to fire at any time during such fire, without distinguishing in the formal model any cooler nodal elements, is always safe but very conservative. In addition, as the fire develops the differentiation between the temperature values relating to the beam web and to the beam flanges becomes more visible. This effect is particularly significant in the presence of a massive floor slab adjacent the upper flange of a frame I-beam which effectively cools it.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 25-34
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pseudo-static test of steel-glulam composite beam-to-column exterior joints
Autorzy:
Duan, Shaowei
Liu, Xinglong
Yuan, Jian
Wang, Zhifeng
Powiązania:
https://bibliotekanauki.pl/articles/1853633.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
połączenie belka-słup
połączenie zewnętrzne
belka stalowa klejona
belka kompozytowa
test pseudostatyczny
forma przekroju
rozpraszanie energii
nośność
beam to column joint
exterior joint
steel-glulam beam
composite beam
pseudo-static test
cross-section form
energy dissipation
capacity
Opis:
Steel-glulam structure is a new type of composite structure,glulam have lateral support effect on steel plate, that can prevent premature buckling of steel plate and improve the stability of steel structure. In order to study the influence of column’s cross-section form on the seismic performance of steel-glulam composite beam-to-column exterior joint, the column’s cross-section form was taken as the basic variable (glulam rectangular section , H-beam section and H-beam-glulam rectangular section were used respectively). The pseudo-static tests of three composite beam-to-column joints were carried out to observe the different failure modes, and obtain the mechanical performance indexes. The experiment results demonstrated that: The energy dissipation capacity of beam-to-column exterior joint composed of glulam column was the worst, the ultimate bearing capacity and stiffness were the lowest. The ultimate bearing capacity of the exterior joints formed by the H-beam column and the H-beam-glulam composite column were both high, and their ductility coefficients were similar, while the former had better energy dissipation capacity.
Źródło:
Archives of Civil Engineering; 2021, 67, 1; 147-161
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ambiguity in determining the critical temperature of a steel sway frame with semi-rigid joints
Niejednoznaczność w wyznaczaniu temperatury krytycznej stalowej ramy przechyłowej z podatnymi węzłami
Autorzy:
Maslak, M.
Pazdanowski, M.
Snela, M.
Powiązania:
https://bibliotekanauki.pl/articles/1849756.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odporność ogniowa
rama stalowa
temperatura krytyczna
węzeł sztywny
węzeł półsztywny
węzeł doczołowy
węzeł belka-słup
fire resistance
steel frame
critical temperature
fully rigid joint
semi rigid joint
end plate joint
beam to column joint
Opis:
The problem of uniqueness and representativeness of steel frame fire resistance assessment is considered in this paper. The thesis, that the selection of analysis method determines the result in both qualitative and quantitative terms is given scrutiny. It is also shown, that the differences between computed values may be significant. The selection of an appropriate computational model for an analysis of this type seems to be especially important, as the possible overestimation of the fire resistance determined during computation is equivalent to an unjustified optimism of the user with respect to the safety level warranted. In the considerations presented here the critical temperature determined for the whole bearing structure is considered as the measure of sought resistance. The determined temperature is associated with the bearing structure reaching the bearing capacity limit state subject to fire conditions, treated as accidental design situation. Two alternative computational methods have been applied during calculations: the first one - classical, based on 1st order statics and using the buckling length concept for members of the considered frame, and the second one - taking account of 2nd order phenomena via simple amplification of the horizontal loads applied to the frame. Special attention has been paid to the influence exerted on the final fire resistance of the considered structure by the real joint rigidity, decreasing with increasing temperature of the structural members. The obtained results differ not only in the value of determined temperature but also in the indicated location of the weakest frame component, determining its safety.
W pracy rozważa się problem jednoznaczności i reprezentatywności oszacowania odporności ogniowej ramy stalowej. Weryfikacji poddano tezę, że wybór metody analizy determinuje uzyskany wynik zarówno pod względem ilościowym jak i jakościowym, a różnice pomiędzy wyliczonymi wartościami mogą okazać się znaczące. Dobór miarodajnego modelu obliczeniowego w tego typu analizie wydaje się być szczególnie ważny, bowiem ewentualne przeszacowanie wyznaczonej z obliczeń odporności jest równoznaczne z nieuzasadnionym optymizmem użytkownika budynku co do gwarantowanego mu poziomu bezpieczeństwa. W prezentowanych rozważaniach miarą poszukiwanej odporności jest temperatura krytyczna specyfikowana dla całego ustroju nośnego. Nie zależy ona od prognozowanego scenariusza rozwoju pożaru i z tego względu może zostać uznana za pewnego rodzaju charakterystykę samej konstrukcji. Wyznaczana temperatura kojarzona jest z osiągnięciem przez ustrój nośny stanu granicznego nośności w warunkach pożaru traktowanego jako wyjątkowa sytuacja projektowa. Nie oznacza to jednak natychmiastowej katastrofy badanej konstrukcji ale jedynie sytuację, gdy prawdopodobieństwo tego rodzaju zdarzenia staje się już na tyle duże że nie może być dalej akceptowane. Do szczegółowej analizy wykorzystano dwie alternatywne procedury obliczeń: pierwszą - opartą o klasyczną statykę pierwszego rzędu, z wykorzystaniem koncepcji długości wyboczeniowej elementów badanej ramy, i drugą - uwzględniającą efekty drugiego rzędu przez prostą amplifikację przyłożonego do tej ramy obciążenia poziomego.
Źródło:
Archives of Civil Engineering; 2020, 66, 4; 611-632
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the End-Plate Thickness on the Steel Beam-to-Column Joint Stiffness when Subject to Bending
Autorzy:
Maślak, M.
Pazdanowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/104294.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
beam-to-column steel end-plate joint
end-plate thickness
joint flexibility
initial stiffness
numerical simulation
Opis:
Based on the numerical simulation performed within the Abaqus computational environment for a typical end-plate beam-to-column joint the influence of the endplate thickness on the effective joint rigidity has been verified. The initial joint rigidity at first determined for 20 mm thick end-plate has been compared with rigidity of the joint constructed with substantially more flexible end-plates 10, 8 and 6 mm thick. In all the considered cases the column was equipped with horizontal ribs stiffening the web at the height of beam top and bottom flange. No diagonal ribs were applied. In addition the column flange at the zone directly adjacent to the beam end-plate in all the analyzed cases has been set to 30 mm. This way it did not affect the computationally determined rigidity of considered joints. Juxtaposition of M-ϕ curves characterizing the considered joints and depicting the relationship between the applied bending moment and relative change of the initial angle between undeformed axes of beam and column in the analyzed frame indicates qualitatively different modes of destruction of the considered joints, and thus different computational models determining their bearing capacity. In the first case obtained parameters seem to indicate that the joint is nominally rigid but in all the remaining cases the bearing capacity seems to be exhausted by the increasing deformation of the more and more flexible end-plate.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 145-156
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental tests of steel unstiffened double side joints with flush and extended end plate
Badania doświadczalne doczołowych obustronnych nieużebrowanych węzłów z blachą wpuszczoną i wystającą
Autorzy:
Kozłowski, Aleksander
Kukla, Damian
Powiązania:
https://bibliotekanauki.pl/articles/230940.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
węzeł dwustronny
węzeł doczołowy
badanie doświadczalne
połączenie belka-słup
odporność
węzeł podatny
akcja cięgnowa
utrata słupa
double side joint
experimental test
beam-to-column connection
robustness
semi-rigid joint
column loss
Opis:
Experimental tests of steel unstiffened double side bolted end-plate joints have been presented. The main aim of the conducted tests was to check the behavior of joints in an accidental situation and possibility of creating secondary mechanism, i.e. catenary action in the scenario of column loss. Two types of end plate joints were tested: flush end-plate (FP) and extended end-plate (EP) with different thickness and different number of bolt rows in each. The tests were carried out on an isolated cross beam-column-beam type system until joint failure. During tests the available moment resistance and rotation capacity of bending joints and also values of tension forces in the beam were determined. The joints with extended end-plate have demonstrated higher bending and rotational capacity than flush end-plate. Significant deformation of column flanges, web and end plate were observed. The fracture of bolts was the failure mode of joints. Obtained results of axial force values in beam exceeded standard requirement what confirmed that the joints with unstiffened web column, flush or extended end-plate possess the ability of development the catenary action.
W artykule przedstawiono badania doświadczalne śrubowych doczołowych nieużebrowanych węzłów obustronnych. Głównym celem badań było sprawdzenie możliwości utworzenia mechanizmu wtórnego, tzw. akcji cięgnowej w scenariuszu utraty słupa. Badaniu poddano dwa typy wezłów doczołowych: z blachą wpuszczoną (FP) i z blachą wystającą (EP) o różnej grubości oraz różnej liczbie rzędów śrub. Badania wykonano na wyizolowanym układzie krzyżowym belka-słup-belka do momentu zniszczenia połączenia. Wynikiem badań było określenie nośności połączeń przy zginaniu, ustalenie zdolności do obrotu tego typu połączeń oraz ustalenie wartości sił rozciągających w belkach. Połączenia z blachą wystającą wykazały większą nośność na zginanie oraz zdolność do obrotu niż węzły z blachą wpuszczoną. Miejscami znacznych odkształceń węzła były pasy i środnik słupa oraz blacha czołowa. Modelem zniszczenia węzłów było zerwanie śrub. Uzyskane w badaniach wartości siły osiowej w belkach przekroczyły wartości normowe, co potwierdza, że połączenia z nieużebrowanym środnikiem słupa, z blachą wpuszczoną lub blachą wystającą posiadają zdolność rozwoju akcji cięgnowej.
Źródło:
Archives of Civil Engineering; 2019, 65, 4; 127-154
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies