Tytuł:
Fluctuation of radiocaesium concentrations in the near-surface atmospheric layer in Białystok in the period 1992-1999
Autorzy:
Kapała, J.
Zalewski, M.
Tomczak, M.
Mnich, Z.
Karpińska, M.
Powiązania:
https://bibliotekanauki.pl/articles/147161.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
air contamination
Chernobyl accident
Cs-137
Opis:
Air samples were collected at an early-warning sampling and monitoring radioactive contamination station ASS-500. The results of the measurements are presented for radioactive aerosols collected on filters each week between 1992 and 1999. The large variations in activity concentration were observed in annual cycles. The maximum values exceeded the mean annual values by a factor of 2.8 to 7.3. Over the period of eight years the mean values of activity in air was found to decrease from 5.3 mi Bq m-3 in 1992 to 2.2 mi Bq m-3 in 1999. A good correlation between the Cs-137 activity and dust content in the air indicates that in the observed period the main source of Cs-137 activity is the dust with soil and vegetation particles. The effect of radiation from inhalation is negligible (626 pSv).
Źródło:
Nukleonika; 2002, 47, 2; 69-73
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of trees for reducing particulate matter pollution in air
Autorzy:
Dzierżanowski, K.
Gawroński, S. W.
Powiązania:
https://bibliotekanauki.pl/articles/115807.pdf
Data publikacji:
2011
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Tematy:
air contamination
PM
phytoremediation
coarse particles
urban forest
Opis:
Adverse health effects of environmental pollution is a frequent subject of medical and veterinary studies. One of the most dangerous air contaminants is particulate matter (PM). Planting trees as biological filters is considered as a valuable way of reducing number of particles in air. However, there is not enough research on selecting the most efficient plant species/varieties for accumulation of these pollutants. In this study, five commonly cultivated tree species were compared: silver birch, Simon’s poplar, callery pear ‘Chanticleer’, northern red oak and Swedish whitebeam, to identify the differences in accumulation levels of PM on leaf surface. Results showed that all of the tested species accumulated high amounts of PM. Whitebeam and birch were most effective in capturing particles, while lowest levels were found on oak.
Źródło:
Challenges of Modern Technology; 2011, 2, 1; 69-73
2082-2863
2353-4419
Pojawia się w:
Challenges of Modern Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of regularities of ground-level air radionuclide contamination at the Russian coast of the Baltic Sea in the course of the long-term Leningrad Nuclear Power Plant (1983-1999) operation
Autorzy:
Blinova, L.
Goloubeva, L.
Dushin, V.
Michurina, T.
Powiązania:
https://bibliotekanauki.pl/articles/148106.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
air contamination
artificial radionuclides
7Be
nuclear power plant
Opis:
Long-term results of ground-level air radionuclide contamination at the Russian coast of the Baltic Sea (nuclear facilities in the vicinity of the town of Sosnovy Bor) are under consideration. As compared with 1992-1997 [1], the Leningrad Nuclear Power Plant (NPP) equipment hermetic sealing (in 1998-1999) caused both the reduction of detection frequency of 131I aerosol and the maximum concentrations of 137Cs in the ground-level air at the NPP site. Long-term weekly nuclides' concentration time series were examined by the correlation analysis. Results of the analysis are presented. The seasonal fluctuations of 7Be concentrations in the ground-level air were examined by the harmonic (Fourier) analysis. The seasonal fluctuations of its concentrations with the maximum in spring-summer period are shown.
Źródło:
Nukleonika; 2001, 46, 4; 179-182
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor-Outdoor Relations for PM10 Mass Concentration Based on University Building
Relacja outdoor-indoor dla stężenia masowego PM10 na przykładzie budynku uczelni
Autorzy:
Lenart, M.
Olszowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/388248.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
air contamination
aerosols
public building
PCA
zanieczyszczenia powietrza
aerozole
budynki użyteczności publicznej
Opis:
The determination of the level of pollutants and reciprocal relations “outside-inside” forms an important component in the study involving assessment and control of indoor air quality. This paper reports the results of a study with regard to the mass concentration of PM10 determined concurrently in the outdoor air surrounding a university building and inside the lecture rooms in it. The research project was undertaken in the cold season and registration included 83 independent observations with the duration of 90 minutes. The research applied a reference method involving measurements of PM10 mass concentration using gravimetric technique. The results were analyzed by application of non-parametric tests. For the purposes of classification of variables and assessment of the role of the specific variables, the analysis was based on the use of principal components. It was indicated that the mass concentration of particulate matter in the lecture rooms dśs not differ from the levels measured at the same time in the air surrounding the building only during the periods corresponding to periodic room ventilation. It was also found that the design and usage of the buildings, as well as the number and activity of humans determine the aerosanitary conditions in the enclosed spaces formed by the lecture rooms. It was observed that the mass concentration of particulate matter in the rooms is higher in the cold season. A statement was made that design solutions need to be implemented with the purpose of using intelligent ventilation systems.
Określenie udziału źródeł zanieczyszczeń oraz wzajemnej relacji „outside-inside” jest istotnym problemem w szacowaniu i kontroli jakości powietrza wewnętrznego. Artykuł przedstawia wyniki badań nad stężeniem masowym PM10 określonym jednocześnie w okalającym budynek powietrzu zewnętrznym oraz w salach dydaktycznych uczelni wyższej. Projekt badawczy przeprowadzono w sezonie chłodnym, rejestrując 84 niezależne, 90-minutowe obserwacje. W badaniach wykorzystano, opartą na grawimetrii, referencyjną metodę pomiaru stężenia masowego PM10. Rezultaty badań przeanalizowano przy użyciu testów nieparametrycznych. W badaniach, celem klasyfikacji zmiennych i oszacowania odpowiedzialności poszczególnych czynników, posłużono się analizą składowych głównych. Wykazano, że wartości stężenia masowego pyłu zmierzonego w salach dydaktycznych nie różnią się od poziomów określonych jednocześnie w okalającym budynek powietrzu zewnętrznym wyłącznie podczas okresowego wietrzenia pomieszczeń. Stwierdzono, że konstrukcja oraz sposób użytkowania budynku a także liczba i aktywność osób w znaczący sposób determinują warunki aerosanitarne w pomieszczeniach zamkniętych. Wykazano, że w sezonie chłodnym stężenie masowe pyłu zawieszonego jest wyższe w pomieszczeniach. Złożono postulat przyjęcia rozwiązań polegających na implementacji inteligentnych systemów wentylacyjnych.
Źródło:
Ecological Chemistry and Engineering. A; 2016, 23, 2; 127-137
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy monitoringu zanieczyszczeń mikrobiologicznych powietrza
The problems of microbiological air contamination monitoring
Autorzy:
Chmiel, M.
Frączek, K.
Grzyb, J.
Powiązania:
https://bibliotekanauki.pl/articles/339315.pdf
Data publikacji:
2015
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
air contamination
bacteria
bioaerosol
fungi
microorganisms
bakterie
bioaerozol
grzyby
mikroorganizmy
zanieczyszczenie powietrza
Opis:
W pracy omówiono składniki bioaerozolu ze szczególnym uwzględnieniem zanieczyszczeń mikrobiologicznych (bakterii i grzybów), źródeł ich pochodzenia (naturalne i antropogeniczne) oraz rozprzestrzeniania się i zagrożeń wynikających z obecności drobnoustrojów w powietrzu wewnętrznym i atmosferycznym. Przedstawiono przykładowe choroby, których czynniki przenoszone są drogą powietrzną, oraz problemy związane z regularnym monitoringiem zanieczyszczeń biologicznych atmosfery. Odrębną część pracy poświęcono sposobom badań mikrobiologicznych, przedstawiono krótko wybrane metody badań powietrza oraz omówiono ich wady i zalety. W ostatniej części przedstawiono problemy dotyczące oceny stopnia zanieczyszczenia powietrza przez drobnoustroje. Problemy te wynikają z braku obowiązujących norm oraz innych regulacji prawnych związanych z mikrobiologicznym skażeniem powietrza, które umożliwiałyby jednoznaczną interpretację wyników badań.
This study discusses the components of bio-aerosol – with particular emphasis on the microbiological contaminants (bacteria and fungi), their sources (natural and anthropogenic), spread and risks resulting from the presence of microorganisms in the indoor and atmospheric air. The paper presents examples of diseases transmitted by air and the problems associated with regular monitoring of microbiological contamination of the atmosphere. A part of the work is devoted to the methods of microbiological testing of air pollution and presents briefly chosen methods and discusses their advantages and disadvantages. The last section presents problems with assessing the degree of air pollution by microorganisms resulting from the absence of applicable standards and other regulations related to the microbiological contamination of air, which would allow for unambiguous interpretation of research results
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2015, 15, 1; 17-27
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exposure assessment of airborne contaminants in the indoor environment of Irish swine farms
Autorzy:
Mc, Donnell P E
Coggins, M.A.
Hogan, V.J.
Fleming, G.T.
Powiązania:
https://bibliotekanauki.pl/articles/51964.pdf
Data publikacji:
2008
Wydawca:
Instytut Medycyny Wsi
Tematy:
carbon dioxide
farm worker
occupational exposure
indoor environment
ammonia
pig farm
Ireland
air contaminant
agricultural worker
air contamination
endotoxin
Źródło:
Annals of Agricultural and Environmental Medicine; 2008, 15, 2
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czynniki mikrobiologiczne na pokładzie lekkich samolotów pasażerskich
Microbial Agents on Board of Light Passenger Aircrafts
Autorzy:
Stobnicka, A.
Górny, R.
Gołofit-Szymczak, M.
Cyprowski, M.
Ławniczek-Wałczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818069.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
lekkie samoloty pasażerskie
zanieczyszczenie powietrza
bakterie
grzyby
bioaerozol
light passenger aircrafts
air contamination
bacteria
fungi
bioaerosol
Opis:
Light passenger aircrafts, also known as „air taxis”, are a fast and comfortable way of transport, which becomes more and more popular nowadays. However, there is a lack of publications regarding harmful biological agents in the cabin air of light passenger aircrafts. The aim of the study was a quantitative and qualitative evaluation of microbial contamination of cabin air in eight light passenger aircrafts with open cabin type and two helicopters. The bioaerosol sampling was carried out with a stationary, volumetric method using MAS-100 NT impactor. The concentration of microorganisms was expressed as CFU/m3.The highest concentration of bacteria was detected in the helicopter Robinson R44 Raven 2 I (175 CFU/3), while the highest concentration of fungi was detected in the plane model TB9 Socata Tampico (385 CFU/m3). Kruskal-Wallis test did not show any statistically significant difference in the concentration of microorganisms in the air between the tested aircrafts, and between them and the outside background.The predominant groups of microorganisms in bioaerosols were fungi and Gram-positive cocci, which constituted 31.1-83.0% and 5.6-62.2% of the total microbiota, respectively. Sixteen species of bacteria belonging to the 8 types and 14 species of fungi belonging to 13 genera were identified in the samples.The qualitative analysis showed the presence of bacterial and fungal saprophytic strains belonging to the 1. risk group, and species belonging to the 2. risk group (Bacillus subtilis, Streptomyces spp.). Taking into account the influence of temperature and relative humidity on the concentration of bacteria and fungi in the air, it was observed that the higher temperature determined the higher concentration of bacteria, but there was no such relationship concerning fungi. Relative humidity did not significantly determine the concentration of bioaerosols.Our results indicate that the concentrations of bacteria and fungi in the cabin air were very low. However, even such an environment cannot be considered as free from pathogens. As shown by the results, the bioaerosols in the cabin air of light passenger aircrafts may contain potentially pathogenic bacteria and fungi belonging to the 2. risk group. However, bioaerosols may contain potentially pathogenic bacteria and fungi belonging to the 2. risk group. Direct contact with the afore-mentioned microorganisms, especially in the case of people with weakened immunity systems, can cause adverse health effects, as well as allergic reactions.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 492-505
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological air contamination in premises of the primary health-care
Ocena poziomu zanieczyszczenia mikrobiologicznego powietrza w wybranych pomieszczeniach placówki podstawowej opieki zdrowotnej
Autorzy:
Karwowska, E.
Miaśkiewicz-Pęska, E.
Andrzejewska-Morzuch, D
Powiązania:
https://bibliotekanauki.pl/articles/204804.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air contamination
bacteria
mould
health-care premises
zanieczyszczenie powietrza
zanieczyszczenie bakteriologiczne
bakteria
pleśń
pomieszczenia służby zdrowia
Opis:
The aim of this research was to evaluate the microbiological indoor air contamination level in chosen facilities of the primary health-care for adults and children. The total numbers of mesophilic bacteria, staphylococci, coli-group bacteria and moulds in both surgery rooms and patients’ waiting rooms were determined. Air samples were collected with a MAS 100 impactor and the concentration of microorganisms was estimated by a culture method. The microbiological air contamination level was diverse: the number of mesophilic bacteria ranged from 320 to 560 CFU/m3, number of staphylococci – 10–305 CFU/m3, coli group bacteria – 0–15 CFU/m3 and moulds – 15–35 CFU/m3. The bacteriological contamination level of the air in examined community health centers was higher than described in the literature for hospitals and exceeded the acceptable values proposed for the surgery objects.
Przedmiotem pracy była analiza liczebności mikroorganizmów w wytypowanych pomieszczeniach służby zdrowia w placówce podstawowej opieki zdrowotnej. Zakres badań obejmował określenie stężenia bakterii mezofilnych, gronkowców, bakterii grupy coli oraz grzybów pleśniowych w powietrzu poczekalni dla chorych, gabinetu lekarskiego oraz punktu szczepień. Próbki pobierano za pomocą aparatu MAS 100 firmy Merck a liczebność mikroorganizmów szacowano metodą hodowlaną. Stwierdzono, iż poziom zanieczyszczenia mikrobiologicznego powietrza badanych pomieszczeń był zróżnicowany. Liczebność bakterii mezofi lnych kształtowała się na poziomie 320–560 JTK/m3, gronkowców – 10–305 JTK/m3, bakterii grupy coli – 0–15 JTK/m3 a grzybów pleśniowych – 15–35 JTK/m3. Poziom zanieczyszczenia bakteriologicznego w badanej placówce opieki zdrowotnej był wyższy niż ten dopuszczalny dla pomieszczeń szpitalnych w tym sal operacyjnych.
Źródło:
Archives of Environmental Protection; 2013, 39, 4; 51-58
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Environmental exposure to airborbe asbestos fibres in a highly urbanized city
Autorzy:
Krakowiak, E
Gorny, R.L.
Cembrzynska, J.
Sakol, G.
Boissier-Draghi, M.
Anczyk, E.
Powiązania:
https://bibliotekanauki.pl/articles/50447.pdf
Data publikacji:
2009
Wydawca:
Instytut Medycyny Wsi
Tematy:
asbestos fibre
asbestos-containing material
air contamination
environmental exposure
monitoring
health hazard
people
town
city
building construction
Źródło:
Annals of Agricultural and Environmental Medicine; 2009, 16, 1; 121-128
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbial air contamination on the premises of the sewage treatment plant in Bydgoszcz (Poland) and antibiotic resistance of Staphylococcus spp.
Mikrobiologiczne zanieczyszczenie powietrza na terenie oczyszczalni ścieków oraz antybiotykooporność bakterii z rodzaju Staphylococcus spp.
Autorzy:
Małecka-Adamowicz, M.
Kubera, Ł.
Donderski, W.
Kolet, K.
Powiązania:
https://bibliotekanauki.pl/articles/205206.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bioaerosols
treatment plant
Antimicrobial resistance
air contamination
bioaerozol
oczyszczalnia
środki przeciwdrobnoustrojowe
oporność na środki przeciwdrobnoustrojowe
zanieczyszczenie powietrza
Opis:
The study was aimed at evaluating microbial contamination on the premises of the sewage treatment plant by determining the concentrations of selected groups of airborne microorganisms. Another objective was to determine the antibiotic sensitivity patterns of isolated strains of staphylococci. The research was conducted in a seasonal cycle, by the impaction method using Merck MAS-100 air sampler. Samples were collected at six sites, each representing a different stage of sewage treatment. The susceptibility of isolated staphylococci was assessed with the disc-diffusion method, following the recommendations of the EUCAST. The results indicate that the microbial population in the air of the investigated area was dominated by mold fungi, whose highest average concentration was recorded at site IV located near the final clarifier (7672 CFU•m-3). Heterotrophic bacteria and mannitol-positive staphylococci were the most numerous at locations where sewage undergoes primary treatment. In each subseuqent stage the number of microorganisms emitted into the air from the sewage was lower. Antibiograms show that more than 50% of Staphylococcus spp. exhibited resistance to penicillin and 20% to rifampicin. In addition, 90% of the analyzed strains were sensitive to other antibiotics. The fungal community included the following genera: Cladosporium, Fusarium, Alternaria, Penicillium, Aspergillus, Aureobasidium, and Acremonium.The highest air contamination with all studied groups of microorganisms was recorded at the locations where mechanical sewage treatment was performed. During the subsequent stages lower numbers of heterotrophic bacteria were emitted into the air. The air in the investigated sewage treatment plant did not contain multidrug-resistant staphylococci.
Celem pracy była ocena stopnia mikrobiologicznego zanieczyszczenia powietrza na terenie oczyszczalni ścieków, określonego na podstawie liczebności wybranych grup drobnoustrojów oraz ocena wrażliwości wyizolowanych szczepów gronkowców na wybrane antybiotyki, co pozwoliło określić stopień ich antybiotykooporności. Badania przeprowadzono w cyklu sezonowym, przy użyciu metody zderzeniowej za pomocą próbnika MAS-100 Merck. Próbki pobierane były z 6 stanowisk badawczych zlokalizowanych w miejscach reprezentujących poszczególne etapy oczyszczania ścieków. Lekowrażliwość wyizolowanych gronkowców oceniano metodą dyfuzyjno-krążkową zgodnie z rekomendacjami EUCAST. Analizy wykazały, że wśród mikrobiota powietrza najliczniej występowały grzyby pleśniowe osiągając maksimum liczebności na stanowisku IV zlokalizowanym przy osadniku wtórnym radialnym (7672 CFU•m-3). Bakterie heterotroficzne i gronkowce mannitolododatnie najliczniej występowały w miejscach wstępnego etapu oczyszczania ścieków. Wraz z zaawansowaniem procesów oczyszczania, ścieki emitowały do powietrza atmosferycznego coraz mniejszą ilość mikroorganizmów. Na podstawie antybiogramów stwierdzono, że ponad 50% badanych szczepów Staphylococcus spp. wykazywała oporność wobec penicyliny i 20% wobec rifampicyny, natomiast 90% analizowanych szczepów było wrażliwych na pozostałe antybiotyki. Wśród grzybów pleśniowych w powietrzu na terenie oczyszczalni ścieków odnotowano grzyby z rodzaju: Cladosporium, Fusarium, Alternaria, Penicillium, Aspergillus, Aureobasidium i Acremonium. Największym zanieczyszczeniem powietrza, w przypadku wszystkich badanych grup mikroorganizmów, charakteryzowały się stanowiska zlokalizowane w miejscach odpowiedzialnych za część mechaniczną procesu oczyszczania ścieków. Wraz z zaawansowaniem procesów oczyszczania, ścieki emitowały do powietrza atmosferycznego coraz mniejszą ilość bakterii heterotroficznych. Na terenie oczyszczalni ścieków nie stwierdzono rozprzestrzeniania się szczepów gronkowców wielolekoopornych.
Źródło:
Archives of Environmental Protection; 2017, 43, 4; 58-65
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of average exhaust emissions from a farm tractor operating in a livestock building
Ocena sredniej emisji spalin z ciagnika pracujacego w budynku inwentarskim
Autorzy:
Karbowy, A.
Koniuszy, A.
Sedlak, P.
Powiązania:
https://bibliotekanauki.pl/articles/793309.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
livestock building
microclimate
engine load
exhaust emission
farm tractor
carbon dioxide emission
water vapour
environment
temperature
air contamination
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oceny wyrobów zawierających azbest a badania powietrza (cz. I)
Estimations of asbestos containing materials and investigations of air. Part I
Autorzy:
Obmiński, A.
Powiązania:
https://bibliotekanauki.pl/articles/182763.pdf
Data publikacji:
2011
Wydawca:
Instytut Techniki Budowlanej
Tematy:
wyrób azbestopochodny
ocena
przepis prawny
obiekt przemysłowy
instalacja
zanieczyszczenie powietrza
asbestos containing material
estimation
regulation
Polska
industry facility
installation
air contamination
Opis:
Opisano problemy uznaniowości „ocen” wyrobów azbestowych według obowiązujących w Polsce przepisów i konsekwencje złych decyzji postępowania z nimi. Problem ten jest ważny, zwłaszcza wobec ocenianych materiałów z azbestem umiejscowionych w dużych obiektach, fabrykach, albo instalacjach. Oceny materiałów w takich lokalizacjach wymagają dodatkowych badań i weryfikacji.
The problems with “discretionary estimations” of asbestos in the existing regulations in Poland, and the consequences of wrong usage decisions have been described. This problem seems to be important, especially when estimated materials are situated in buildings, big factories or installations. Additional research works and verifications are required in such localizations.
Źródło:
Prace Instytutu Techniki Budowlanej; 2011, R. 40, nr 4, 4; 17-29
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oznaczenie stężenia struktur azbestowych w powietrzu – nowa metoda
Determination of the concentration of asbestos structures in the air – a new method
Autorzy:
Rożkowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/2062730.pdf
Data publikacji:
2012
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
azbest
ochrona powietrza
zanieczyszczenie powietrza azbestem
metoda badawcza
transmisyjny mikroskop elektronowy
niskotemperaturowa plazma
asbestos
air protection
air contamination by asbestos
research method
transmission electron microscope
low-temperature oxygen plasma
Opis:
Azbest jest toksycznym minerałem, który powoduje wyniszczające efekty zdrowotne u ludzi. Z powodu jego toksyczności konieczne jest posiadanie skutecznych metod do wykrywania i kwantyfikacji azbestu w środowisku. Przez lata opracowano wiele metod, jednak każda z tych metod ma swoje mocne i słabe strony. Publikacja przedstawia kompleksową metodę kontroli stężeń struktur azbestowych w powietrzu. Metoda zawiera procedury: lokalizacji punktów pobierania próbek, pobierania próbek z powietrza, przygotowania próbek do analizy, identyfikacji struktur na podstawie cech morfologicznych, chemicznych, strukturalnych, zliczania struktur w próbce i wyznaczania stężenia struktur azbestowych w powietrzu.
Asbestos is a toxic mineral known to produce debilitating health effects in humans. Because of its toxicity, it is necessary to have effective methods to detect asbestos in the environment. Over the years, a number of methods have been developed, but each method has its own strengths and weaknesses. The paper presents the composite method for the control of concentrations of asbestos structures in the air. The method involves the following procedures: location of sample collection points, collection of air samples, preparation of samples for analysis, identification of structures based on morphological, chemical and structural features, counting of asbestos structures in the sample and determination of concentrations of asbestos structures in the air.
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2012, 450; 83--90
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The interaction between the indoor environment and building construction
Oddziaływanie pomiędzy środowiskiem zewnętrznym a konstrukcją budynku
Autorzy:
Toth, S.
Vojtus, J.
Powiązania:
https://bibliotekanauki.pl/articles/2065257.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska
Tematy:
historic buildings
incorrect utilization
mildew
air contamination
air sampling
biological factors
indoor environment
fungoid organisms
budynki historyczne
nieprawidłowa eksploatacja
pleśń
zanieczyszczenie powietrza
pobieranie próbek powietrza
czynniki biologiczne
środowisko wewnętrzne
grzyby
Opis:
The project listed in the acknowledgment focused on monitoring the occurrence of various fungus genera within building constructions of residential, non-residential and historic buildings. Fungoid organisms found on indoor surface of building constructions are a serious aesthetic and constructional/structural disadvantage with enormous impact on the interior environment of exploitable space. They can be found not only in rooms of old buildings, but also in newly built or reconstructed areas, where one would not expect them. Greater amounts of fungoid organisms occurring in artificial environments are harmful to humans. Therefore professional information provided to the public concerning their harmful impact not only on construction materials, but also on human health is very necessary.
Celem projektu jest monitorowanie występowania różnych rodzajów grzybów wewnątrz konstrukcji budynków mieszkalnych, niemieszkalnych oraz zabytkowych. Grzyby znajdowane na wewnętrznej powierzchni konstrukcji budowlanych w swojej najprostszej postaci jako pleśń są poważną estetyczną i konstrukcyjno-strukturalną wadą z ogromnym wpływem na jakość środowiska wnętrz. Można je znaleźć nie tylko w pomieszczeniach starych budynków, ale również w nowo budowanych lub przebudowywanych obiektach, gdzie nie powinny występować. Duża ilość grzybów obserwowana w sztucznie stworzonym środowisku w pomieszczeniach jest szkodliwa dla ludzi. Dlatego też profesjonalne informacje podane do publicznej wiadomości, dotyczące ich szkodliwego wpływu nie tylko na materiały budowlane, ale także na zdrowie ludzi, są bardzo potrzebne.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2014, 1 (13); 130--137
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of bioaerosols in the air around the facilities of waste collection and disposal
Autorzy:
Roodbari, A.
Naddafi, K.
Javid, A.
Powiązania:
https://bibliotekanauki.pl/articles/207127.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
utylizacja odpadów
aerozole
stężenie mikroorganizmów
bioaerozol
bakterie
zbieranie odpadów
gospodarka odpadami
zanieczyszczenie powietrza
waste disposal
aerosols
bacteria
microbial concentrations
bioaerosol
total bacteria
waste collection
waste management systems
air contamination
Opis:
Exposure to bioaerosols at various stages of waste management system (collection, transfer and disposal) has been evaluated by recording of the bacterial and fungal concentrations in the air around these facilities. Regardless of the season, the total bacteria and total fungi were detected for all sampies, whereas the fungal genera were not. The bioaerosol concentrations measured in the waste collection bins were significantly higher than those of the transfer station and landfill site. The mean microbial concentrations at wastes container bins and in-operation trench exceeded the Iran outdoor bioaerosol guidelines (850 CFU/m3), thus suggesting the need for remedial action regarding microorganisms, in order to reduce the exposure at the wastes management system.
Źródło:
Environment Protection Engineering; 2013, 39, 4; 105-112
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Dominant Microbial Air Pollutants in Hospital Environments and Nearby Areas in Albania
Autorzy:
Troja, Erjon
Ceci, Ranela
Markaj, Albana
Dhamo, Eltion
Troja, Rozana
Powiązania:
https://bibliotekanauki.pl/articles/1838419.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
microbial contamination
air quality
hospital environment
Tirana
Albania
Opis:
Nowadays, one of the most important and essential aspects of having a healthy and safe life is the air safety and its quality in indoor and outdoor environments. In the air, there are not only chemical pollutants but also biological ones, with specific impacts. Hospital environments are among the most likely to be affected by the microbiological contamination of the air; therefore its quality is particularly important. Pathogenic microorganisms, which may be present in the air, can cause nosocomial infections in hospitalized patients, with compromised immune system or other medical conditions. This paper reflects the evaluation of microbiological air contamination, in different hospital environments and nearby areas, in the city of Tirana. The microbial air quality has been monitored during the period of 2009–2018, performing evaluations every three years, in the same area and the same time of the year. In order to build a database for understanding the impact of developmental changes on the air microbiological loads, results of similar studies conducted earlier, during 2007 and 2008 were also taken into consideration. The above-mentioned period was selected because of the changes in the infrastructure and indoor environments of the monitored area, where many patients have been treated for years. Changes have been made over the years to hospital structures and surroundings, including recreational facilities, clinical service units, as well as main and connecting roads, etc. The obtained results, which were compared over the years, provided a clear view of the changing microbiological air loads, influenced by the improvements of indoor and outdoor areas. The morphological studies of the observed, isolated, purified and identified microorganisms revealed the presence of specific mold loads, with the dominance of the species of Aspergillus genus and those of the group Fungi imperfecti. Over the years, a decrease in the total number was observed (from 103 to 101), together with a smaller number of bacteria (1012), in the monitored environments.
Źródło:
Journal of Ecological Engineering; 2021, 22, 5; 32-38
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza źródeł zanieczyszczenia miasta Rzeszowa
The analysis of the sources of contamination the city of Rzeszow
Autorzy:
Kalda, G.
Kwaśniak, K.
Sokolan, J.
Powiązania:
https://bibliotekanauki.pl/articles/104394.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
zanieczyszczenia
woda
powietrze
gleba
hałas
contamination
water
air
soil
noise
Opis:
W artykule prezentowano analizę takich źródeł zanieczyszczenia miasta Rzeszowa, jak zakłady przemysłowe i komunalne, które są źródłami zanieczyszczenia wód powierzchniowych i podziemnych miasta Rzeszowa. Także przeanalizowano zanieczyszczenie gleby miasta, powietrza i środowiska źródłami hałasu. Rozwój gospodarczy miasta Rzeszowa, a przede wszystkim wzrost produkcji przemysłowej oraz procesy urbanizacyjne stwarzają poważne zagrożenie dla zasobów wód powierzchniowych i podziemnych, powietrza i gleby. Pokazano, że zawartości poszczególnych substancji i metali ciężkich w wymienionych jednolitych częściach wód powierzchniowych w Rzeszowie nie przekraczają wartości normatywnych. Do najbardziej rozpowszechnionych zanieczyszczeń gleby Rzeszowa można zaliczyć metale ciężkie (np. ołów, rtęć, miedź, kadm); związki organiczne (pestycydy); sole siarczany, azotany, chlorki. Do głównych źródeł emisji zanieczyszczeń antropogenicznych do gleby na terenie Rzeszowa zalicza się procesy produkcyjne w zakładach przemysłowych; procesy spalania paliw na cele energetyczne i transport. Na stan powierza w Rzeszowie wpływa przede wszystkim emisja liniowa i powierzchniowa. Sektor komunalno-bytowy w dużej mierze odpowiada za zwiększone stężenia pyłu zawieszonego oraz benzo(a)pirenu w sezonie grzewczym. Stosowane w gospodarstwach domowych niskosprawne urządzenia i instalacje kotłowe, ich zły stan techniczny, nieprawidłowa eksploatacja, a także spalanie złej jakości paliw i odpadów komunalnych są główną przyczyną tzw. niskiej emisji. Największe przekroczenia dopuszczalnych poziomów hałasu można zaobserwować na obszarach sąsiadujących z drogami krajowymi, drogą wojewódzką, a także w centrum miasta, czyli w miejscach, gdzie odbywa się największy ruch pojazdów.
The article has presented analysis such sources of contamination the city of Rzeszow, as industrial plants and municipal facilities, which are source devastation surface waters and groundwater the city of Rzeszow. Also analyzed contamination of soil, air and environment the source of noise. Economy development the city of Rzeszow, but the most of all increase industrial productions and urbanization process created real danger for deposits surface waters and groundwater, air and soil. In the article presented analyzed environmental contaminations the city of Rzeszow from industrial and municipal types of sources. Shown, that the contents of individual substances and heavy metals in listed uniform parts of surface waters in Rzeszow not exceed normative values. To the most prevalent Rzeszow soil contaminants may include the heavy metals (e.g. lead, mercury, copper, cadmium); organic compounds (pesticides); salts, sulfates, nitrates, chlorides. To main sources emission of anthropogenic contamination to soil on territory of Rzeszow may include manufacturing processes in industrial plants; combustion of fuels for energy purposes and transport. For condition of air in Rzeszow depends first of all linearly and surface emission. The public utilities sector are largely response for increased concentration of particulate matter and benzo(a)pyren in heating season. Used in households low-efficiency device and boilers, their bad technical condition, incorrect exploitation and also combustion bad quality of fuels and garbage are main cause the so-called low emission. The biggest excessive norms of noise can observed on areas neighbouring with national routes, voivodeship route and also the city-center, in the other words in places, which hosts the largest traffic.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 4/I; 73-86
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Drilling for Shale Gas on the Quality of Atmospheric Air
Wpływ prac wiertniczych prowadzonych za gazem ziemnym w łupkach na jakość powietrza atmosferycznego
Autorzy:
Macuda, J.
Bogacki, M.
Siemek, J.
Powiązania:
https://bibliotekanauki.pl/articles/371274.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Komitet Człowiek i Środowisko PAN
Tematy:
drilling works
shales
shale gas
air quality
emission of pollutants
dust and gaseous pollutants
contamination of air
mathematical modeling
prace wiertnicze
łupki
gaz z łupków
jakość powietrza
emisja zanieczyszczeń
zanieczyszczenia pyłowe i gazowe
zanieczyszczenie powietrza
modelowanie matematyczne
Opis:
Shale gas is an alternative for conventional energy sources. When extracted in compliance with environmental and sustained development rules, it favors the concept of diversification of energy sources, giving spur to the development of economy and technology, and before all, to the energy safety of the country. Poland is among countries, where expectations regarding shale gas are very high. Most of the exploration works for shale gas there are performed with the use of rigs, whose subassemblies are driven by electrical motors powered by mobile generators driven by diesel engines. The number of aggregates and their total power are selected each time on the basis of power balance of particular technological subassemblies and the emergency generation system. Diesel combustion motors used for powering generators are the only source of dust and gaseous emissions to the air. A mobile technological boiler room fed with oil is another source of emissions in the winter period. For the purpose of evaluating impact of rigs on the air environment in the course of prospecting for shale gas an emission model was worked out with five emission points. Four sources were connected with the operation of combustion motors (each 1257 kW) powering generators, and the fifth one (375 kW) feeding technological boiler room. The results of the tests on the environmental impact on motors and boiler room used during shale gas prospecting on the quality of air have been presented in the paper. The tests were performed with the use of mathematical modeling employing real technological data from existing installations.
Gaz z formacji łupkowych stanowi alternatywę dla konwencjonalnych źródeł energii. Wydobywany z poszanowaniem wymogów ochrony środowiska oraz w zgodzie z regułami zrównoważonego rozwoju jest elementem bezpieczeństwa energetycznego państwa, wpisuje się w logikę dywersyfikacji źródeł energii oraz stanowi impuls do rozwoju gospodarczego i naukowo-technicznego kraju. Polska należy do krajów, w których z gazem łupkowym wiąże się duże nadzieje. Tutaj proces wiercenia otworów poszukiwawczych za gazem ziemnych w skałach łupkowych w większości przypadków prowadzony jest przy wykorzystaniu urządzeń wiertniczych, w których poszczególne podzespoły napędzane są silnikami elektrycznymi. Jednak źródłem energii elektrycznej są dla nich mobilne zestawy generatorów napędzane silnikami wysokoprężnymi dużej mocy. Ilość agregatów oraz ich sumaryczna moc dobierana jest każdorazowo w oparciu o wykonany bilans mocy poszczególnych podzespołów technologicznych i systemu zasilania awaryjnego. Wysokoprężne silniki spalinowe dużej mocy, wykorzystywane do napędu generatorów prądu, stanowią istotne źródło emisji zanieczyszczeń pyłowo-gazowych do powietrza. Ponadto w okresie zimowym dodatkowym źródłem emisji do powietrza jest mobilna kontenerowa kotłownia technologiczna zasilana olejem opałowym. Dla potrzeb oceny wpływu pracujących urządzeń wiertniczych na jakość powietrza w trakcie prowadzenia prac poszukiwawczych za gazem ziemnym w skałach łupkowych, w stworzonym modelu emisyjnym założono pracę 5 punktowych źródeł emisji zorganizowanej. Cztery źródła są związane z pracą silników spalinowych, każdy o mocy 1257 kW, napędzających generatory, a piąty z pracą kotłowni technologicznej o mocy 375 kW. W artykule przedstawiono wyniki badań wpływu na jakość powietrza silników spalinowych oraz kotłowni wykorzystywanych przy realizacji prac wiertniczych związanych z poszukiwaniem gazu ziemnego w skałach łupkowych. Badania prowadzone były metodą modelowania matematycznego w oparciu o rzeczywiste dane technologiczne pochodzące z obszaru wierceń poszukiwawczych.
Źródło:
Problemy Ekorozwoju; 2017, 12, 1; 91-100
1895-6912
Pojawia się w:
Problemy Ekorozwoju
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrobiologiczne zanieczyszczenie powietrza na terenie oczyszczalni ścieków komunalnych
Microbiological air pollution in the area of municipal sewage treatment plant
Autorzy:
Budzińska, K.
Jurek, A.
Szejniuk, B.
Michalska, M.
Wroński, G.
Powiązania:
https://bibliotekanauki.pl/articles/1819427.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
komunalna oczyszczalnia ścieków
zanieczyszczenie powietrza
zanieczyszczenie mikrobiologiczne
municipal sewage treatment plant
air pollution
microbiological contamination
Opis:
Doświadczenia prowadzone w zasięgu oddziaływania oczyszczalni ścieków wykazały, że skład gatunkowy i ilościowy mikroflory powietrza jest ściśle powiązany z rodzajem i liczbą mikroorganizmów obecnych w ściekach. W skład bioaerozoli w rejonach oczyszczalni ścieków wchodzą bakterie, wirusy oraz liczne gatunki grzybów, w tym mikotoksyczne i alergizujące. Takie aerozole biologiczne sprzyjają odczynom alergicznym, chorobom zakaźnym, a nawet epidemiom i epizootiom. Według doniesień literaturowych [2, 5, 10] czynnikiem umożliwiającym powstawanie bioaerozolu wokół oczyszczalni jest liczba mikroorganizmów obecnych w ściekach. Jako graniczną wartość przyjmuje się zawartość drobnoustrojów na poziomie wyższym od 103 w 1 ml, co warunkuje możliwość uniesienia komórek do powietrza [15]. Do podstawowych parametrów decydujących o zasięgu i stopniu oddziaływania wpływu oczyszczalni ścieków na mikrobiologiczną czystość powietrza należą: wielkość obiektu, stosowana technologia procesów oczyszczania ścieków, sposób przeróbki i postępowania z osadami ściekowymi, staranność eksploatacji obiektów i inne [1, 2]. Drobnoustroje trafiają do powietrza przede wszystkim na skutek realizacji procesów związanych z napowietrzaniem i mieszaniem ścieków oraz rozprowadzaniem ich na urządzeniach biologicznych [11÷13]. W ciągu technologicznym oczyszczalni ścieków można wyróżnić kilka newralgicznych punktów, które w sposób szczególny wpływają na emisję bioaerozoli. Najbardziej negatywny wpływ odnotowano w przypadku urządzeń takich jak kratownia, pompownia wstępna, kanały ścieków surowych, piaskownik, komora napowietrzania i poletka osadowe [5]. Duże ryzyko zdrowotne związane z emisją szkodliwych bioaerozoli powoduje, że konieczne jest prowadzenie kontroli czystości mikrobiologicznej powietrza na terenie i wokół oczyszczalni ścieków. Celem badań było określenie zanieczyszczenia mikrobiologicznego powietrza na terenie mechaniczno-biologicznej oczyszczalni ścieków komunalnych.
The aim of this study was to estimate a degree of microbiological air pollution in the area of a mechanical-biological municipal sewage treatment plant. Four measurement points were situated in the area of the and one research stand was located outside the plant from the windward side (background) - near screen, near sand catchers, at aeration chambers, at sewage sludge deposition site. Air samples were collected in a trail of pollution with the compaction method using the sampler SAS 100. The microbiological analyses involved the quantitative analysis of the following microorganisms: total number of bacteria and fungi, haemolysing staphylococci and , mannitol-positive and mannitol-negative staphylococci, Pseudomonas fluorescens, actinomyces and bac-teria of the Enterobacteriaceae family. Total number of bacteria in particular measurement points varied and ranged from 320 to 4565 cfu in 1 m3 of air. The highest emission of those microorganisms was observed in the vicinity of appliances for mechanical sewage treatment (screen site). The next measurement point where a high number of bacteria was recorded was location in the vicinity of the sewage sludge deposition site. The number of mould fungi occurring in the air at all the measurement points was low and ranged from 420 to 5429 colonies.m-3. The highest concentration of actinomyces in the air was observed in the vicinity of the sewage sludge storage site, where their number ranged from 55 to 450 cfu.m-3. The highest emission of Pseudomonas fluorescens from sewage to the air was observed at the point over the aeration chamber, where in the summer period the number of these bacteria exceeded two-fold 50 cfu.m3, which indicates strong air pollution. The largest number of haemolysing bacteria of type was found at all measurement stands in the spring-summer period, where their concentration from 0 to 48 cfu.m-3. The number of type bacteria determined in the air at the measurement points was within the range from 0 to 27 cfu.m-3, and the largest number was found at the point located over the aeration chamber. The study also involved the determination of the number of mannitol-positive staphylo-cocci, which values permissible for clean air should not exceed 100 cfu.m-3. Mannitol-positive staphylococci in the examined air oc-curred at a low level and in no samples exceeded the number for clean air proposed in the project PN-Z-04111-1 concerning air cleanliness protection. The concentration of potentially pathogenic bacteria of the Entero-bacteriaceae family was the highest in air samples collected in the vicini-ty of the sewage sludge storage place, where their number oscillated from 67 to 523 cfu.m-3, and at the screen site (22-320 cfu.m-3). The results of the study show that sludge-drying beds are an important source of micro-organism emission on the premises of a sewage treatment plant. The greatest number of microorganisms was found in air samples collected in late spring and summer. The exception was actinomyces, which occurred in the maximal amount in autumn. The assessment of degree of air pollu-tion indicates that there is a potential risk of exposure sewage treatment plant staff to harmful biological factors leading to disease incidence (bacteria of the Enterobacteriaceae family, and -haemolysing microor-ganisms and mannitol-positive staphylococci). The investigations show the need for constant monitoring of the effect of a sewage treatment plant on the air environment, which will enable efficient prevention of people working at sewage treatment plants.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1543-1558
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of microbial contamination of atmospheric air in a selected wastewater treatment plant
Ocena skażenia mikrobiologicznego powietrza atmosferycznego w wybranej oczyszczalni ścieków
Autorzy:
Paśmionka, Iwona B.
Powiązania:
https://bibliotekanauki.pl/articles/204604.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
microbial contamination
bioaerosol
sewage treatment plant
atmospheric air
skażenie mikrobiologiczne
bioaerozol
oczyszczalnia ścieków
powietrze atmosferyczne
Opis:
The aim of the research was to determine the microbiological quality of atmospheric air in the Tuchów Sewage Treatment Plant, based on the presence of mesophilic bacteria, α- and β-hemolytic bacteria, actinomycetes and fungi. Bioaerosol measurements were made at four points (raw sewage inlet, aeration chamber, purified sewage outlet and 150 m from the treatment plant, at the background point) in the period from January to December 2018. Bioaerosol samples were collected using Andersen’s 6-stage cascade impactor. The tested atmospheric air was characterized by a qualitatively and quantitatively diverse microflora. The highest amounts of all the studied groups of microorganisms were found at the raw sewage inlet, and in the case of actinomycetes, also twice in the place of biological purification. However, there were analyzes in which a higher concentration of microorganisms was observed outside the treatment plant at the control point constituting the background. This applies to bacteria and fungi. The largest source of emission of microorganisms to the atmosphere was the mechanical part of the sewage treatment plant (raw sewage inlet). The tested treatment plant may therefore contribute to the deterioration of the quality of the atmospheric air.
Celem prowadzonych badań było określenie jakości mikrobiologicznej powietrza atmosferycznego na terenie Oczyszczalni Ścieków w Tuchowie, na podstawie występowania bakterii mezofilnych, bakterii α- and β-hemolizujących, promieniowców i grzybów. Pomiary bioaerozolu wykonano w czterech punktach (wlot ścieków surowych, komora napowietrzania, wylot ścieków oczyszczonych oraz 150 m od oczyszczalni, w punkcie stanowiącym tło) w okresie od stycznia do grudnia 2018 r. Próbki bioaerozolu pobierano za pomocą 6-stopniowego impaktora kaskadowego Andersena. Badane powietrze atmosferyczne charakteryzowało się zróżnicowaną ilościowo i jakościowo mikroflorą. Najwyższe ilości wszystkich badanych grup mikroorganizmów stwierdzono przy wlocie ścieków surowych, a w przypadku promieniowców również dwukrotnie w miejscu biologicznego oczyszczania. Zdarzały się jednak analizy, w których wyższe stężenie drobnoustrojów obserwowano poza terenem oczyszczalni, w punkcie kontrolnym stanowiącym tło. Dotyczyło to bakterii i grzybów. Największym źródłem emisji mikroorganizmów do atmosfery była mechaniczna część oczyszczalni (wlot ścieków surowych). Badana oczyszczalnia może więc przyczyniać się do pogorszenia jakości powietrza atmosferycznego.
Źródło:
Archives of Environmental Protection; 2019, 45, 4; 60-67
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Scaling of two-phase capillary pressure-saturation relationships: water-air and oil-air systems
Autorzy:
Kodesova, R.
Kutilek, M.
Vesela, J.
Matula, S.
Powiązania:
https://bibliotekanauki.pl/articles/25411.pdf
Data publikacji:
2003
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
interfacial tension
oil-air system
capillary pressure-saturation relationship
ground water
immiscible phase
water-air system
soil contamination
non-aqueous phase liquid
Źródło:
International Agrophysics; 2003, 17, 4
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Childrens allergic diseases and microbial contamination of indoor air - a case report
Autorzy:
Kasznia-Kocot, J
Lis, D.O.
Kordys-Darmolinska, B.
Grzybowska-Chlebowczyk, U.
Wos, H.
Gorny, R.L.
Powiązania:
https://bibliotekanauki.pl/articles/51486.pdf
Data publikacji:
2007
Wydawca:
Instytut Medycyny Wsi
Tematy:
human disease
asthma
perennial rhinitis
microbial contamination
indoor air
allergy
child
bacteria
damp house
fungi
allergen
Opis:
The assessment of exposure to bioaerosols in damp houses of two children who suffered from perennial rhinitis and asthma was performed. The paper presents an approach to the complex (i.e., medical and environmental) treatment of allergic diseases.
Źródło:
Annals of Agricultural and Environmental Medicine; 2007, 14, 1
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Poprawa stanu mikrobiologicznego powietrza w przemyśle spożywczym
Autorzy:
Małecki, Z. J.
Małecka, I.
Powiązania:
https://bibliotekanauki.pl/articles/407606.pdf
Data publikacji:
2010
Wydawca:
Instytut Badawczo-Rozwojowy Inżynierii Lądowej i Wodnej Euroexbud
Tematy:
instalacja wentylacyjna
skażenie mikrobiologiczne
filtry powietrza
kanały poliestrowe
ventilation system
microbial contamination
air filters
polyester channels
Opis:
Wentylacja w przemyśle spożywczym w sensie technicznym jest to wymiana powietrza w pomieszczeniach w celu usunięcia zbędnego ciepła i poprawienia stanu mikrobiologicznego. Skażenia mikrobiologiczne urządzeń technologicznych oraz urządzeń i instalacji m. in. wentylacyjno - klimatyzacyjnych, mają wpływ na rozwój bakterii chorobotwórczych. Zarazki przyczepiają się do cząstek pyłu znajdującego się w powietrzu, dlatego obserwuje się wzrost liczby zarazków wraz ze wzrostem zapylenia. Urządzenia wentylacyjne (klimatyzatory) mogą przenosić różne bakterie chorobotwórcze np. powodujące zapalenie płuc (choroba legionistów). Powstawanie punktu rosy, przy stosunkowo wysokiej temperaturze i wilgotności względnej, może przyczynić się z dużym prawdopodobieństwem do pogorszenia się warunków mikrobiologicznych (mogą wystąpić tzw. zarodki kondensacji). W przemyśle spożywczym występują często zanieczyszczenia w postaci substancji zapachowych pochodzących z procesów technologicznych. W ostatnim czasie szerokie zastosowanie znalazły przewody tekstylne wykonane z tkaniny poliestrowej spełniające także funkcję filtrów powietrza. Niezależnie od poprawy rozwiązań technologicznych należy likwidować pierwotne i wtórne skażenia mikrobiologiczne poprzez zastosowanie: wysokosprawnych filtrów powietrza, czyszczenia i dezynfekcji instalacji wentylacyjnej, lamp bakteriobójczych.
Źródło:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska; 2010, 2; 24-32
2082-6702
Pojawia się w:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Contamination of soils with heavy metals in the industrialized region of western Ukraine: western Podole Upland
Zanieczyszczenia metalami ciężkimi gleb uprzemysłowionego rejonu zachodniej Ukrainy
Autorzy:
Mandryk, O.
Radlovska, K.
Powiązania:
https://bibliotekanauki.pl/articles/385356.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
soil contamination
heavy metals
air pollution
industrial emission
Western Ukraine
zanieczyszczenie gleby
metale ciężkie
zanieczyszczenia powietrza
zanieczyszczenie przemysłowe
zachodnia Ukraina
Opis:
Contamination of surface soil horizons with heavy metals is usually related to long-lasting air pollution and might potentially affect soil fauna, as well as plant growth, harvesting and health of plant consumer. In order to estimate potential health risk, we investigated surface and subsurface soil contamination with heavy metals in avable area in one of the most industrialized region of western Ukraine, western Podole Upland. In total 80 samples from the area of about 35 km2 were sampled and analyzed for content of zinc, nickel, copper, cobalt, lead, arsenic and quicksilver. The research revealed several anomalies, where the content of these elements exceed 3-5 Ukrainian quality guidance for avable soils. Soils are the most contaminated with arsenic and quicksilver, with maximum concentrations exceeding local geochemical background about 20 times. Maximum nickel and zinc concentrations are about 10 times higher than the background while the content of copper and cobalt is elevated up to several times.
Zanieczyszczenie powierzchni gleb metalami ciężkimi jest zazwyczaj wiązane z długotrwałym zanieczyszczeniem powietrza i może wpłynąć na faunę glebową, a także na wzrost roślin oraz zdrowie konsumentów. W celu oszacowania potencjalnego zagrożenia dla zdrowa autorzy badali zanieczyszczenie metalami ciężkimi powierzchni gruntów ornych w jednym z najbardziej uprzemysłowionych regionów zachodniej Ukrainy - zachodnim Podolu. Z powierzchni około 35 km2 pobrano w sumie 80 próbek, które przebadano i przeanalizowano pod względem zawartości cynku, niklu, miedzi, kobaltu, ołowiu, arsenu i rtęci. Badania wykazały liczne nieprawidłowości. Zawartość tych pierwiastków przekracza 3-5 ukraińskich norm jakości gleb uprawnych. Gleby te są najbardziej zanieczyszczone związkami arsenu i rtęci, których maksymalne stężenia lokalnie przekraczają normy geochemiczne aż 20-krotnie. Stężenie niklu i cynku wynosi maksymalnie około 10 razy więcej, niż przewiduje norma, podczas gdy zawartość miedzi i kobaltu jest podwyższona kilkukrotnie.
Źródło:
Geomatics and Environmental Engineering; 2013, 7, 1; 75-82
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości wykorzystania oznaczeń izotopowych węgla do oceny zanieczyszczenia fazy gazowej środowiska przyrodniczego
Possibility of using carbon isotopes in the assessment of the pollution of gas phase in environmental research
Autorzy:
Porowska, D.
Powiązania:
https://bibliotekanauki.pl/articles/399787.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
badania izotopowe węgla
zanieczyszczenia powietrza
zasięg oddziaływania składowiska odpadów
carbon isotope composition
air pollution
extent of the contamination zone around the landfill
Opis:
Badania izotopowe węgla mogą być wykorzystywane do celów poznawczych oraz praktycznych. Mogą służyć określeniu genezy węgla w wybranym środowisku geochemicznym, jak również mogą być stosowane do wykazania zanieczyszczenia środowiska związkami zawierającymi węgiel. Celem artykułu jest przedstawienie szerokich możliwości wykorzystania oznaczeń izotopowych węgla do interpretacji dotyczącej następujących elementów środowiska przyrodniczego: powietrza atmosferycznego, strefy przypowierzchniowej (gazów w glebie i strefie aeracji) pod kątem naturalnych i antropogenicznych czynników wpływających na stan ich jakości. Przeprowadzona analiza wykazała, że metoda opierająca się o pomiary składu izotopowego węgla w środowisku przyrodniczym może być stosowana powszechnie, wówczas gdy węgiel pochodzący z poszczególnych źródeł różni się składem izotopowym.
Carbon isotope analyses can be used for knowledge and practical purpose. They can be used to assess the genesis of carbon in geochemical environment, and may also be used to indicate environmental contamination by carbon-containing compounds. The aim of the paper is to indicate the possibilities of using carbon isotope composition for interpretation concerning the following elements of the natural environment: atmospheric air, subsurface zone (gases in soils and aeration zone) in terms of natural and anthropogenic factors influencing on their quality. This method can be applied universally, when carbon sources are different in isotopic composition.
Źródło:
Inżynieria Ekologiczna; 2015, 44; 68-73
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Centralne laboratorium ochrony radiologicznej: retrospekcja i współczesność
Central Laboratory for Radiological Protection
Autorzy:
Bielski, M.
Powiązania:
https://bibliotekanauki.pl/articles/214526.pdf
Data publikacji:
2018
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
materiały radioaktywne
organizacja pracy i zarządzania
BHP i ochrona zdrowia
farby radowe
metody analityczne i pomiarowe
radionuklidy naturalne i sztuczne
przyrządy oraz stacje monitoringu radioaktywnych zanieczyszczeń powietrza
wody i gleby
system Bezpieczeństwa Jądrowego i Ochrony Radiologicznej w Polsce
radioactive materials
work organization and management
work safety and health protection
rad Ra-226 painting
analytical and measurement techniques
natural and anthropogenic
radionuclides
devices and stations for monitoring air contamination
water and soil pollutions
Nuclear Safety and Radiation Protection system in Poland
Opis:
Nawiązując do przypadającego w 2017 r. jubileuszu 60-lecia działalności Centralnego Laboratorium Ochrony Radiologicznej (CLOR) w Warszawie w wywiadzie z dr. Pawłem Krajewskim, dyrektorem CLOR, prezentowane są zagadnienia związane z pracą badawczą i operacyjną tej placówki na przestrzeni lat 1957-2017. Omówiono m.in. opracowane i stosowane w CLOR metody pomiarowe, techniki i technologie oraz skonstruowane w CLOR nowe rodzaje aparatury dozymetrycznej i radiometrycznej, na które uzyskano patenty. Przedstawiono także aktywne uczestnictwo pracowników CLOR w naukowych programach i projektach badawczych krajowych i międzynarodowych. Szczególną uwagę zwrócono na zainicjowaną przez CLOR akcję profilaktyczną, będącą ewenementem na skalę światową, a skierowaną na ochronę ludności, w związku z awarią EJ w Czarnobylu (podanie 18,5 mln Polaków jednorazowej dawki jodu stabilnego, o wielkości zależnej od wieku biorcy). W drugiej części tekstu skoncentrowano się na realizacji zadań, jakie należy podjąć w celu dalszego unowocześnienia systemu Bezpieczeństwa Jądrowego i Ochrony Radiologicznej w Polsce (BJiOR), w tym wzmocnienia systemu zaplecza merytorycznego Technical Suport Organization (TSO).
Referring to the 60th anniversary of the establishment of the Central Laboratory for Radiological Protection in Warsaw, the interview with its Director, Paweł Krajewski presents several issues on research and operational activities of CLOR e during the period of 1957-2017. Among other issues, new measurements methods, developed and implemented in CLOR, new kinds of radiometric and dosimetric devices for which the patents have been granted, were touched upon in the interview. Also, the focus was on the active participation CLOR’s staff in science, research and development projects both at national and international levels. In addition to that, particular attention was paid to the most spectacular action undertaken by CLOR in 1986 just after Chernobyl accident, when prophylactic doses of stable iodine were administered to about 18.5 million of Poles in various amounts depending on a recipient’s age. In the second part of the interview the important questions of modernization and strengthening the Polish system of Nuclear Safety and Radiation Protection and problems of Technical Support Organizations were discussed.
Źródło:
Postępy Techniki Jądrowej; 2018, 1; 2-6
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modernisation through Contamination: Degradation of the Natural Environment in Poland (1945–70) as Perceived by the Authorities and the Society
Autorzy:
Jarosz, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/601571.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Instytut Historii im. Tadeusza Manteuffla PAN w Warszawie
Tematy:
protection of (natural) environment
ecology in (post-war) communist Poland (the People’s Republic of Poland)
communism vs. ecology
contamination of waters
pollution of the air
Opis:
The period 1945–70 saw a change in the approach to environmental contamination on the part of Polish authorities and the society. Before 1956, the imposed model of economic modernisation, which imitated and reproduced the Soviet patterns, glaringly contradicted the requirements of ecology. In the aftermath of the political turn of 1956, protection of waters and air against pollution finally became a matter of debate involving the authorities and the society. Basic legal solutions in this respect, meant to protect the environment against degradation, were adopted in the 1960s. The legislators generally followed the arguments and reasons behind the period’s industrial policy, with the resulting limited efficiency of the legal acts adopted. In any case, between 1956 and 1970 awareness emerged in the society with respect to threats to the environment. This is attested by the letters sent to the authorities whose authors, individuals and groups, criticised the developments of industrial modernisation – owing, primarily, to its detrimental impact on their health.
Źródło:
Acta Poloniae Historica; 2017, 115
0001-6829
Pojawia się w:
Acta Poloniae Historica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zanieczyszczenie wód i powietrza w Polsce w latach 1945–1970 jako problem władzy i społeczeństwa
Autorzy:
Jarosz, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/689948.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Instytut Historii im. Tadeusza Manteuffla PAN w Warszawie
Tematy:
ochrona środowiska
ekologia w Polsce po II wojnie światowej
skażenie i zanieczyszczenie wody
zanieczyszczenie powietrza
environment protection
ecology in Poland after WWII
contamination and pollution of waters
air pollution
Opis:
Artykuł zawiera próbę odpowiedzi na pytanie, jak problem zanieczyszczenia wód i powietrza w Polsce był traktowany przez władze Polski i społeczeństwo w latach 1945–1956. Przedmiotem analizy są: dyskurs na ten temat, ustawodawstwo o ochronie środowiska naturalnego oraz jego praktyczne funkcjonowanie, tworzenie i rozwój struktur organizacyjnych, które zajmowały się kontrolą stanu zanieczyszczeń powietrza i wód, początki świadomości ekologicznej społeczeństwa polskiego. Pollution of air and water in Poland in the years 1945–1970 as a problem of the government and the societyImmediately after the war a discussion about the condition of the natural environment in Poland was held mainly in the specialist press that emphasised its degradation as especially dangerous for the society biologically and psychically wasted by experiences of the war. During the period of deStalinisation and political “thaw” after the 1956 October the subject of air and water pollution was more and more present in the press, but also in discussions of both the leaders of the state and some organised circles of the society. An increasingly well-known deteriorating state of the natural environment which adversely affected economic performance forced the government to search for remedies. As a result, new legal regulations were introduced with accompanying organisational changes. The most important of them were: the establishment of the Ministry of Navigation and Water Management (1957), Central Water Management Board (1960), and local structures responsible for the protection of waters from pollution, the introduction of the Water Law (1962), and the enactment of the Air Pollution Protection Act (1966). From 1960s on, systematic pollution tests of waters and air were carried on, which indicated that between 1967 and 1970 the condition of lakes and rivers deteriorated in comparison to the period of 1964–1967. In the same period there was an increased emission of greenhouse gases and reduced dust emissions. The main reasons for this were: the inefficacy of adopted laws (including a penalties system), insufficient financial investments in effective purification equipment, which was technologically outdated in its large part, the lack of qualified personnel specialised in environmental protection. There were, however, in the analysed period some elements of environmental awareness of people which were expressed, among other things, in letters sent by Polish citizens to the government.
Źródło:
Polska 1944/45-1989. Studia i Materiały; 2017, 15
2450-8365
Pojawia się w:
Polska 1944/45-1989. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stopnia skażenia powietrza zarodnikami grzybów pleśniowych, jako istotny czynnik ekspertyzy mikologicznej
The assessment of air contamination with the mould fungi spores as an essential factor of mycological report
Autorzy:
Wiejak, A.
Powiązania:
https://bibliotekanauki.pl/articles/182819.pdf
Data publikacji:
2011
Wydawca:
Instytut Techniki Budowlanej
Tematy:
grzyb pleśniowy
zarodnik
zanieczyszczenie mikrobiologiczne
powietrze wewnętrzne
powietrze zewnętrzne
budynek mieszkalny
wilgotność
ekspertyza techniczna
metoda zderzeniowa
ocena mykologiczna
kryteria oceny
zagrzybienie
wyniki badań
zdrowie człowieka
mould
spore
microbiological contamination
indor air
outdoor air
dwelling house
humidity
technical expertise
impact method
mycological evaluation
mould growth
test results
human health
assessment criteria
Opis:
W artykule przedstawiono wyniki pomiarów stężenia zarodników grzybów pleśniowych wykonanych w trakcie ekspertyz mikologicznych kilkunastu lokali mieszkalnych. Mierzono również wilgotność przegród, określano przyczynę ich zawilgocenia. Porównując stężenie zarodników grzybów w powietrzu wewnętrznym z równolegle określanym stężeniem w powietrzu zewnętrznym, określano stopień skażenia powietrza w lokalach. Wyniki pomiarów odniesiono do powszechnie stosowanych kryteriów.
In the following paper the measurement results of mould fungi spores concentration in several apartments are presented. The compartments humidity was measured and the cause of damp formation was determined. Comparing the concentration of fungi spores in the internal air, with the simultaneously defined concentration in the outside air - the range of air contamination in apartments was specified. Those results were referred to the common used criteria.
Źródło:
Prace Instytutu Techniki Budowlanej; 2011, R. 40, nr 3, 3; 3-12
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zanieczyszczenie powietrza w budynkach preparatami pochodzenia smołowego
Indoor air pollution in buildings by chemicals originated from tar products
Autorzy:
Niesłochowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/183219.pdf
Data publikacji:
2011
Wydawca:
Instytut Techniki Budowlanej
Tematy:
zanieczyszczenie powietrza
zanieczyszczenie chemiczne
powietrze wewnętrzne
budynek mieszkalny
budynek użyteczności publicznej
olej impregnacyjny
XYLAMIT
środek bitumiczny
rozpuszczalnik organiczny
para organiczna
emisja par
badanie laboratoryjne
chromatografia gazowa
technika analiz
air pollution
chemical contamination
indor air
dwelling house
public building
impregnation oil
tar composition
organic solvent
laboratory test
gas chromatography
analysis technique
Opis:
Wyroby budowlane pochodzenia smołowego są przyczyną zanieczyszczenia powietrza wewnątrz budynków. Dotyczy to budynków starych, w których konstrukcje drewniane konserwowane byly preparatami zawierającymi bitumy (olej impregnacyjny Xylamit - lepik smołowy) oraz budynków nowych, w których stosowano preparaty hydroizolacyjne zawierające rozpuszczalniki węglowodorowe. Zastosowanie nowoczesnych technik analitycznych, takich jak GC-MS, desorpcja termiczna, mikroekstrakcja, pozwoliło zidentyfikować przyczynę chemicznego zanieczyszczenia pomieszczeń. W artykule omówiono zwięźle kilka przypadków takich interwencji zaobserwowanych w ostatnich latach.
Buildings materials containing tar products are source of indoor air pollution in buildings. It concerns particularly to old buildings in which wooden structure were impregnated by tar compositions (creosote oil, Xylamit oil tar) and the new one in which bituminous seal containing hydrocarbon solvents were used. New analytical methods (GC-MS, thermal desorption, microextraction) enable to identify in details a reason of chemical indoor air pollution. Some case studies noticed in last years were described briefly.
Źródło:
Prace Instytutu Techniki Budowlanej; 2011, R. 40, nr 2, 2; 3-14
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-30 z 30

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies