Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "active power loss" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
GA based optimal planning of VAR sources using Fast Voltage Stability Index method
Autorzy:
Bhattacharyya, B.
Rani, S.
Vais, I. R.
Bharti, P. I.
Powiązania:
https://bibliotekanauki.pl/articles/140784.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active power loss
FVSI method
genetic algorithm
operating cost
reactive power planning
weak nodes
Opis:
This paper presents a novel approach for reactive power planning of a connected power network. Reactive power planning is nothing but the optimal usage of all reactive power sources i.e., transformer tap setting arrangements, reactive generations of generators and shunt VAR compensators installed at weak nodes. Shunt VAR compensator placement positions are determined by a FVSI (Fast Voltage Stability Index) method. Optimal setting of all reactive power reserves are determined by a GA (genetic algorithm) based optimization method. The effectiveness of the detection of the weak nodes by the FVSI method is validated by comparing the result with two other wellknown methods of weak node detection like Modal analysis and the L-index method. Finally, FVSI based allocation of VAR sources emerges as the most suitable method for reactive power planning.
Źródło:
Archives of Electrical Engineering; 2016, 65, 4; 789-802
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu wybranych odnawialnych źródeł energii na straty mocy czynnej i biernej w systemie elektroenergetycznym
Impact of the selected renewable energy sources on active and reactive power losses in a power system
Autorzy:
Tarakan, B.
Tarakan, K.
Zajczyk, R.
Czapp, S.
Sarnicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/266608.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
odnawialne źródła energii
OZE
farma fotowoltaiczna
farmy wiatrowe
straty mocy czynnej
straty mocy biernej
renewable energy sources
photovoltaic farm
wind farms
loss of active power
loss of reactive power
Opis:
Moc zainstalowana oraz produkcja energii elektrycznej z odnawialnych źródeł energii od kilkunastu lat systematycznie w Polsce wzrasta. Należy spodziewać się, że tendencja ta w najbliższych latach zostanie utrzymana. Dość dużym zainteresowaniem cieszą się źródła wiatrowe oraz źródła fotowoltaiczne, co sprawia, że przy znacznych ich mocach zainstalowanych konieczne staje się badanie wpływu tych źródeł na system elektroenergetyczny. W artykule przedstawiono analizę wpływu farmy fotowoltaicznej i farmy wiatrowej na poziom strat mocy czynnej i biernej w systemie elektroenergetycznym. Obliczenia wykonano z wykorzystaniem programu DIgSILENT PowerFactory.
The rated power and the production of energy from renewable energy sources for several years steadily increases in Poland. It is expected that this trend will be continued in the coming years. Wind and photovoltaic sources are very popular and in consequence it becomes necessary to study the impact of these sources on the power system. The article presents an analysis of the impact of photovoltaic farm and wind farm on the level of loss of active and reactive power in the power system. Calculations were performed with the use of DIgSILENT PowerFactory software.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 51; 27-30
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimal allocation of DG units in distribution system considering variation in active power load
Autorzy:
Kumar, M.V. Likith
Bilgundi, Srishail K.
Pradeepa, H.
Powiązania:
https://bibliotekanauki.pl/articles/140424.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
exact loss formula
loss reduction
loss sensitivity formula
optimal DG placement
uncertainties in active power load
voltage profile
Opis:
High distribution system power-losses are predominantly due to lack of investments in R&D for improving the efficiency of the system and improper planning during installation. Outcomes of this are un-designed extensions of the distributing power lines, the burden on the system components like transformers and overhead (OH) lines/conductors and deficient reactive power supply leading to drop in a system voltage. Distributed generation affects the line power flow and voltage levels on the system equipment. These impacts of distributed generation (DG) may be to improve system efficiency or reduce it depending on the operating environment/conditions of the distribution system and allocation of capacitors. For this purpose, allocating of distributed generation optimally for a given radial distribution system can be useful for the system outlining and improve efficiency. In this paper, a new method is used for optimally allocating the DG units in the radial distribution system to curtail distribution system losses and improve voltage profile. Also, the variation in active power load in the system is considered for effective utilization of DG units. To evidence the effectiveness of the proposed algorithm, computer simulations are carried out in MATLAB software on the IEEE-33 bus system and Vastare practical 116 bus system.
Źródło:
Archives of Electrical Engineering; 2019, 68, 2; 265-277
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of distribution network reconfiguration at daily operation scheduling
Metoda rekonfiguracji sieci w codziennym działaniu
Autorzy:
Golub, I.
Voitov, O. N.
Semenova, L. V.
Boloev, E. V.
Powiązania:
https://bibliotekanauki.pl/articles/952867.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
distribution network
loss reduction
renewable power generation
reconfiguration
active energy consumer
graph theory
sieć dystrybucyjna
redukcja strat
generacja mocy ze źródeł odnawialnych
rekonfiguracja
aktywny odbiorca energii
teoria grafów
Opis:
The paper suggests a two-stage optimization algorithm of daily load curves of a distribution network to decrease electricity purchase costs and determine a primary distribution network configuration in presence of renewable power generation or without it. The first stage includes optimization of the daily load curves of active consumers, which ensures decrease of electricity purchase costs considering its price and daily consumption invariability. At the second stage the problem distribution network reconfiguration is solved to decrease power losses in it. The numerical calculations for the test distribution networks confirm the efficiency of the suggested algorithms.
W poniższym artykule zaproponowano dwustopniowy algorytm optymalizacji dobowego wykresu obciążenia sieci dystrybucyjnej w celu obniżenia kosztów zakupu energii elektrycznej oraz określenia konfiguracji sieci pierwotnej z uwzględnieniem lub bez uwzględnienia źródeł odnawialnych. Pierwszy etap polega na optymalizacji dobowego wykresu obciążeń dla aktywnych odbiorców energii, co zapewni spadek kosztów zakupu energii ze względu na niezmienność cen i poziom zużycia energii. W drugim etapie zajęto się problemem rekonfiguracji sieci dystrybucyjnej w celu zmniejszenia strat mocy z sieci. Przeprowadzone obliczenia numeryczne dla testowej sieci dystrybucyjnej potwierdzają efektywność proponowanych algorytmów.
Źródło:
Acta Energetica; 2017, 2; 57-62
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies