Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "active current" wg kryterium: Temat


Tytuł:
A fuzzy logic approach to shunt active power filter and hybrid active power filter
Autorzy:
Sahoo, Nirjharini
Panda, Gayadhar
Subudhi, B. D.
Powiązania:
https://bibliotekanauki.pl/articles/41189662.pdf
Data publikacji:
2023
Wydawca:
Politechnika Warszawska, Instytut Techniki Cieplnej
Tematy:
Index terms
shunt active power filter
hybrid active power filter
hysteresis current controller
total harmonic distortion (THD)
indirect current controller
filtr mocy czynnej
filtr hybrydowy
zniekształcenie harmoniczne
regulator prądu
Opis:
This paper describes a Fuzzy Logic approach to Shunt Active power filter (SAPF) versus Hybrid Active Power Filter (HAPF) using Simulink. Here hysteresis controlled PWM method is applied to the SAPF and HAPF as a current controller and Fuzzy logic controller as a inverter dc voltage controller. To reduce harmonics, Shunt Active Power Filters (SAPFs) are used with various control schemes, but Hybrid Active power filter is a power electronic device which has both the characteristics of passive power filters and active power filters, which helps in cancelation of the harmonics by producing compensating signal. The fuzzy-hysteresis controller is designed and its simulation results are presented for both the filter types, showing acceptable THD results for the word length used in the fixed-point computations involved in the switching sequence generation. The results of the above controller are compared with the Indirect current controller.
Źródło:
Journal of Power Technologies; 2023, 103, 4; 209-217
1425-1353
Pojawia się w:
Journal of Power Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A hybrid parallel active filter / off-line UPS unit for computer loads
Autorzy:
Ghennam, T.
Darwish, M.
Powiązania:
https://bibliotekanauki.pl/articles/262760.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
active filters
UPS systems
computer power supplies
current harmonics
Opis:
A hybrid parallel active filter / off-line uninterruptible power supply (UPS) system is proposed. The hybrid system contains a single inverter which acts as a parallel active filter during the normal mode of operation (when the AC supply is available); and also supplies the load with energy from the UPS back-up battery during the back-up mode of operation (when the AC supply is not available or is beyond the preset tolerance). In both modes of operations the inverter is controlled in such way so that the line current is a pure sinusoid. This is to improve the input power factor and to eliminate the current harmonics in the first mode and to remove any stress on the back-up battery caused by the discharging during the second mode of operation. A full simulation results and an experimental setup is presented together with a closed loop control algorithm.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2008, 14, 2; 41-48
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new active method of protection against electrical shock in low voltage ship networks: experimental results
Nowa aktywna metoda ochrony przeciwporażeniowej w sieciach okrętowych niskiego napięcia: badania eksperymentalne
Autorzy:
Tarnapowicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/256131.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
ochrona przeciwporażeniowa
kompensacja parametryczna
kompensacja aktywna
falownik czteroprzewodowy
protection against shock current
parametric compensation
active compensation
four-leg inverter
Opis:
The commonly applied electrical networks with an insulated neutral point in ships are not able to protect against electric shock, due to the presence of capacitance between phase wires and the hull, which increases the values of shock current. A new approach to solve this problem is presented. The new idea is based on active compensation of shock current using current sources inserted between the phase wires and the metallic hull. A four-leg transistor inverter controlled by a signal processor (DSP) and a logic programmable array (FPGA) was used as a set of current sources. The arrangement of the test stand obtained for the experimental checking of the concept compensation of shock current is presented together with the experimental results.
Powszechnie stosowane w okrętownictwie sieci elektryczne z izolowanym punktem zerowym z powodu występowania pojemności doziemnych (powodujących wzrost prądu rażenia) nie zapewniają ochrony przeciwporażeniowej. Autor prezentuje nowe podejście do rozwiązania tego problemu. Nowa idea aktywnej kompensacji prądu rażenia człowieka polega na włączaniu pomiędzy przewody fazowe a kadłub statku aktywnych źródeł prądu. W proponowanym rozwiązaniu jako źródła prądowe został wykorzystany falownik w układzie czteroprzewodowym. W referacie przedstawiono układ stanowiska badawczego, przeznaczonego do eksperymentalnego sprawdzenia koncepcji aktywnej kompensacji prądu rażenia w sieciach okrętowych niskiego napięcia, oraz wyniki badań.
Źródło:
Problemy Eksploatacji; 2008, 1; 137-145
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A New Grounded Current Controlled Inductor Based on Simplified Current Conveyors
Autorzy:
M'harzi, Z.
Alami, M.
Temcamani, F.
Powiązania:
https://bibliotekanauki.pl/articles/226248.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active inductor
band-pass filter
BiCMOS technology
integrated circuit (IC)
second generation current controlled conveyor (CCCII)
Opis:
In this paper, a new active grounded inductor controlled in current is described. This structure is realized using negative second generation current controlled conveyors and a single grounded capacitor, with no external resistance. The proposed circuit offers many advantages, such as: operation at high frequencies, simple circuit, tuning by the bias current, low power dissipation, etc. Comparison between this topology and those presented in literature is done to highlight the benefits of our structure. As an application, a bandpass filter based on the proposed active inductance is constructed to confirm the usability of the circuit and illustrate these performances. The filter center frequency and quality factor can be tuned independently. Simulation results, given under PSPICE software, present good agreement with the theoretical ones.
Źródło:
International Journal of Electronics and Telecommunications; 2017, 63, 2; 227-232
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu indukcyjności na charakterystykę hamulca wiroprądowego
Influence of inductance on characteristics of eddy current brake
Autorzy:
Skowron, J.
Powiązania:
https://bibliotekanauki.pl/articles/404037.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Symulacji Komputerowej
Tematy:
indukcyjność
hamulec wiroprądowy
maszyna elektryczna
oporność bierna
oporność czynna
inductance
eddy current brake
electric machine
passive resistance
active resistance
Opis:
Hamulec wiroprądowy można rozpatrywać jako maszynę elektryczną, czyli formę przetwornika elektromechanicznego, który przetwarza energię kinetyczną hamowania pociągu w energię elektryczną rozpraszaną w szynach kolejowych. Takie podejście do rozpatrywanego problemu zastosowano w niniejszej pracy. Otrzymane w ten sposób rozwiązanie przedstawiono w postaci schematu zastępczego maszyny elektrycznej, który nie zawiera oporności indukcyjnej a tylko oporność czynną. Stąd zaproponowano rozwiązanie polegające na wprowadzeniu dodatkowo w schemacie zastępczym maszyny oporności biernej o wartości równej oporności czynnej, co jest zgodne z badaniami empirycznymi.
Eddy current brake can be considered as an electric machine, i.e. type of electromechanical transformer, which shifts kinetic energy of braking train into electric energy dissipated in rails. A substitute model of electric machine is presented in the paper, which contains not only the active resistance in the rotor circuit, but also an inductance. The magnitude of the passive resistance is matched the magnitude of the active resistance, what is in accordance with experiments.
Źródło:
Symulacja w Badaniach i Rozwoju; 2010, 1, 1; 85-92
2081-6154
Pojawia się w:
Symulacja w Badaniach i Rozwoju
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Conductance-controlled global-compensation-type shunt active power filter
Autorzy:
Szromba, A.
Powiązania:
https://bibliotekanauki.pl/articles/140436.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
shunt active power filter
active current
indirect control method
instantaneous compensation
load equivalent conductance
energy flow control
Opis:
This paper presents a load equivalent conductance based control method for a shunt active power filter. The principle of energy balance in the circuit, which means between supplying source - active filter - load, is used to obtain the control formula. The natural inertia of the active filter action is exploited, so no PI regulators are needed. The active filter can compensate for non-active current and, additionally, can stabilise the supplying source active power. In a case of generating loads energy harvesting is possible. The presented method is useful as well for voltage-source as current-source inverter based active filters, and for DC system as well as for AC single- or three-phase one.
Źródło:
Archives of Electrical Engineering; 2015, 64, 2; 259-275
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Control of single-phase power active filters
Sterowanie jednofazowymi energetycznymi filtrami aktywnymi
Autorzy:
Roch, M.
Braciník, P.
Altus, J.
Otčenášová, A.
Powiązania:
https://bibliotekanauki.pl/articles/159873.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
jednofazowy filtr aktywny
analiza Fouriera
wyznaczanie prądu odniesienia
metoda średniej ruchomej
single-phase parallel active filter
Fourier analysis
reference current determination
moving average method
Opis:
This paper deals with three methods of determination of reference current for control of single-phase active filters. All this methods are based on the idea that an ordinary single-phase (system) quantity can be complemented by a fictitious second phase so that both of them will create an orthogonal and orthonormal system.
Artykuł traktuje o trzech metodach ustalania prądu odniesienia do sterowania jednofazowym filtrem aktywnym. Wszystkie te metody bazują na założeniu, że zwykły układ jednofazowy może być uzupełniony przez fikcyjną drugą fazę tak, że obie tworzą układ ortogonalny i ortonormalny.
Źródło:
Prace Instytutu Elektrotechniki; 2012, 258; 201-209
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current control with asymmetrical regular sampled pulse width modulator applied in parallel active filter
Autorzy:
Płatek, T.
Osypiński, T.
Powiązania:
https://bibliotekanauki.pl/articles/202334.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active power filter
asymmetrical regular sampled PWM
current control
filtr aktywny
regulacja prądu
Opis:
This paper presents an analysis of the properties of pulse width modulator with a single (symmetrical regular sampled PWM) and double (asymmetrical regular sampled PWM) control sampling of the input signal (low-frequency control input wave) in presence of a triangular auxiliary signal. In this paper, a comparison of the characteristics of these modulators used in the control system with a linear proportional controller is presented. The article provides the relations derived for the maximum amplification of regulators for which the control system operates stably. Analysis results have been confirmed by simulation and experimental studies of a commercial active filter installed in an industrial plant.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 2; 287-300
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Defekty wirników silników indukcyjnych dużych mocy, termograficzna ocena stanu technicznego
Defects rotor induction motors, large power thermographic evaluation of technical condition
Autorzy:
Ławrowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1367404.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik indukcyjny
wirnik klatkowy
wirnik z prętami biernymi
żelazo czynne
kamera termowizyjna
wymuszalnik prądowy
regulator napięcia
induction motor
squirrel cage rotor
rotor bars of passive
active iron
infrared camera
current controller
voltage regulator
Opis:
The paper presents examples of defects in rotor induction motors and high-power infrared detection methods are also described innovative ways of forcing the flow of current in the cage rotor. The paper is illustrated with a few examples.
W referacie przedstawiono przykładowe defekty w wirnikach silników indukcyjnych dużych mocy oraz termograficznej (termowizyjnej) metody ich wykrywania, opisano także nowatorskie sposoby wymuszania przepływu prądu w klatce wirnika. Referat jest ilustrowany kilkoma przykładami.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 3, 111; 107-113
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of grid disturbances on current source rectifier controlled by FCS-MPC algorithm
Autorzy:
Godlewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/1193668.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
active front end
current source rectifier
model predictive control
active damping
Opis:
Nowadays, the increasing number of non-linear loads influences the grid, causing grid voltage disturbances. These disturbances may be very dangerous for the equipment and can create faults in converter behaviour. However, the right control algorithm can improve the reliability of the work. For a current source rectifier, the finite control set model predictive control has been proposed. This method is very flexible because of the variety of the possible cost function forms. It has been examined under grid voltage disturbed by the higher harmonics and the voltage drop. Simulation results prove the ability to damp the distortions and to ensure the unity power factor. Summing up, the algorithm is a very good solution for use in applications such as battery charging, active power filtering and low-voltage direct current load feeding.
Źródło:
Power Electronics and Drives; 2018, 3, 38; 11-22
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Feedback control of three-Level PWM rectifier: Application to the stabilization of DC Voltages of five-level NPC active power filter
Autorzy:
Abdelkrim, T.
Berkouk, E. M.
Benslimane, T.
Benamrane, K.
Powiązania:
https://bibliotekanauki.pl/articles/229851.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active power filter
NPC multilevel inverter
feedback control
PWM current rectifier
clamping bridge filter
Opis:
One of the most important drawbacks of the three phases five-level NPC (Neutral Point Clamped) Active Power Filter (APF) is the neutral point balance. As the consequence, the capacitors voltages of the input DC bus of the APF are not equal which constitutes the major limitation for the use of this power converter. In order to stabilize these DC voltages, it is proposed in this paper to study the cascade constituted by three phases three-level PWM rectifier-clamping bridge filter-five-level NPC APF. In the first part, the authors present a topology of five-level NPC Voltage Source Inverter (VSI), and then, they propose a model of this converter and its PWM control strategy. In the second part, the modeling and control of three-level PWM current rectifier is presented. In the third part, to remedy to instability problem of the input capacitors DC voltages of the APF, the authors propose feedback control of the three-level PWM rectifier followed by clamping bridge filter. After that, the sliding mode regulator used to control the active filter is developed. The obtained results are full of promise to use this topology of APF in high voltage and high power applications.
Źródło:
Archives of Control Sciences; 2010, 20, 3; 317-339
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
From oil to magnetic fields: active and passive vibration control
Autorzy:
Genta, G.
Festini, A.
Delepine, X.
Powiązania:
https://bibliotekanauki.pl/articles/386935.pdf
Data publikacji:
2008
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
sterowanie drganiami
tłumienie drgań
tłumienie aktywne
vibration control
eddy current dampers
active damping
Opis:
When a reduction of vibration amplitude usually designers resort to dampers based either on dry friction, internal material damping or fluid viscosity, each one of these mechanisms having its peculiar field of application. To improve performance while at the same time reducing costs and environmental load, electromagnetic damping devices are finding new applications, beyond the fields where they have a long history. Moreover, electromagnetic dampers can be easily controlled, obtain active or even ‘intelligent’ vibration control. Three examples from the internal combustion engines, automotive and gas turbine fields are discussed in some detail to show the potential advantages of this technology.
Źródło:
Acta Mechanica et Automatica; 2008, 2, 2; 11-20
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Implementation of a digital signal processor-controlled shunt active filter
Autorzy:
Limongi, L. R.
Cavalcanti, M. C.
Neves, F.
Azevedo, G. M.
Powiązania:
https://bibliotekanauki.pl/articles/262731.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
active filters
current control
power quality
Opis:
This paper presents the implementation of an active filter configuration for harmonic compensation. The system can be controlled for current harmonics and reactive power compensations simultaneously by using a converter operating as active shunt filter. A synchronous reference frame based controller is compared to an instantaneous reactive power based controller. The synchronous reference frame method is chosen to control the converter due to the better performance when the supply voltage is distorted. A shunt active filter system has been designed and built to meet IEEE 519 recommended harmonic standards. Simulation demonstrates the good performance of the active filter configuration. Experimental results, corresponding to the operation of the digital signal processor-controlled shunt active filter are also presented.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 5-14
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the external proximity effect on the power losses in flat three phase high current busduct
Autorzy:
Piątek, Z.
Szczegielniak, T.
Kusiak, D.
Powiązania:
https://bibliotekanauki.pl/articles/97507.pdf
Data publikacji:
2011
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
active power
reactive power
Bessel function
three phase current busduct
Opis:
In the paper the influence of the external proximity effect on the active and reactive power in flat three phase high current busduct were presented. Calculations were made using the Poynting theorem and Joule-Lenz law.
Źródło:
Computer Applications in Electrical Engineering; 2011, 9; 34-44
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Looped-chain-based active current sharing strategy in DC microgrids
Autorzy:
Li, D.
Liu, Y.
Gu, Y.
Qi, H.
Powiązania:
https://bibliotekanauki.pl/articles/141109.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active current sharing
DC microgrids
looped control diagram
Opis:
The integration of renewable energy sources in modern electric grids have drawn increasing attention nowadays. In order to effectively manage large-scale renewable energy sources and achieve flexible and efficient operation, the concept of microgrids have been proposed. Considering the nature of DC outputs in many distributed energy resources (DERs), DC microgrids have been extensively studied in the past years. Among the operational issues in DC microgrids, current sharing issues have become an important topic since it is highly relevant to the operation of DC microgrids. By adopting a proper design of current sharing strategy in DC microgrids, the current rating violations in each interface converter can be successfully avoided. In this paper, a looped-chainbased active current sharing strategy is proposed to realize high accuracy current sharing in DC microgrids. In particular, the output current is shared between the neighboring interface converters. Hence, following a clockwise or counter-clockwise order, a loopedchain- based control diagram can be established to share the reference value of the output current. A final status in the whole DC microgrid is that the output current of every interface converter is equalized. Hence, the desired current sharing objective can be satisfied. A MATLAB simulation model is established to verify the proposed loopedchain- based active current sharing strategy in DC microgrids.
Źródło:
Archives of Electrical Engineering; 2017, 66, 3; 559-569
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies