Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "acoustic emission" wg kryterium: Temat


Tytuł:
Contribution of acoustic emission into optimal bearing lubrication
Autorzy:
Ziegler, B.
Powiązania:
https://bibliotekanauki.pl/articles/242681.pdf
Data publikacji:
2007
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
non-destructive testing
acoustic emission
Opis:
This article describes the bases of the acoustic emission analysis to make successful applications in the range of the tribological problems, especially at machinery slide journal bearings. Acoustic emission differs from ultrasonic testing, which actively probes the structure; Acoustic emission listens for emissions from active defects and is very sensitive to defect activity when a structure is loaded beyond its service load. During detecting and analysing the generated acoustic emission we earn information about the behaviour, state or quality of these acoustic emission sources. A lot of different sources are generating acoustic emission (e.g. corrosion processes, fluid friction, cracks, cutting processes). This paper shows the acoustic emission sources, the wave propagation, the mode conversion, the damping, the design of a typical transducer and the whole measurement chain. The piezoelectric disc, the "heart" of a typical acoustic emission transducer, converts the incoming mechanical wave into a corresponding electrical signal. Every transducer has its own characteristic, if this is unknown we can test it with difficult methods e.g. so called reciprocal method. On the end of this paper the signal parameters (burst-count, rise-time, signal-duration, signal peak amplitude, signal energy and root-mean-square) will be discussed.
Źródło:
Journal of KONES; 2007, 14, 4; 571-578
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing of Railway Prestressed Concrete Sleepers Using Acoustic Emission
Autorzy:
Kowalczyk, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/2203232.pdf
Data publikacji:
2022
Wydawca:
Instytut Kolejnictwa
Tematy:
test sleepers
acoustic emission
crack
Opis:
The article describes the tests of prestressed concrete sleepers made according to the method specified in the requirements of the European standards (EN 13230-2:2009 Railway applications – Track – Concrete sleepers and bearers – Part 2: Prestressed monoblock sleepers) and WTWiO regulations, and an additional measurement method was used – acoustic emission (AE). The purpose of the tests using the acoustic emission method was to verify the results obtained using other test methods described in the European standard. The use of this method in sleeper tests enables obtaining precise data from the sleeper load test and determination of the characteristic parameters based on the recorded AE signals. Due to the variety of existing sleepers and the development of products in this area: wooden sleepers, composite sleepers, steel sleepers (type Y), the use of the acoustic emission method in research will be a good support and will enable proper assessment of these elements of the railway road.
Źródło:
Problemy Kolejnictwa; 2022, 197; 161--174
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lightweight machine enclosures for dynamic and efficient production processes
Autorzy:
Möhring, H.-Christian
Stehle, Thomas
Schneider, Matthias
Powiązania:
https://bibliotekanauki.pl/articles/99419.pdf
Data publikacji:
2019
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
machine tool
safety
acoustic emission
Opis:
Usually machining centres for processing wood-based and composite materials have moving partial machine enclosures in the X-axis direction. Because the workpieces to be machined are often large (e.g. aircraft doors), these partial enclosures have prevailed on the market compared to voluminous complete enclosures. Owing to the general trend towards complete machining through process integration, an increasing number of additional units are integrated into machining centres in addition to the main spindle. This leads to an increase of the mass to be moved as well as a larger and thus heavier partial enclosure. This inevitable increase in mass leads to a deterioration of the dynamic properties of the machine. To counteract this increase in mass, the use of lightweight design materials for machine enclosures becomes in the focus of attention. The lightweight materials to be used must comply with the requirements of modern mechanical engineering and legislation: retention in the event of tool breakage, reduction in the noise exposure of the machine environment and cost-effective solutions compared to the materials used nowadays. The sheet steel used today as material for partial enclosures is therefore to be supplemented or replaced with suitable lightweight design materials. Different lightweight materials are qualified for suitability as machine enclosure. Apart from mass reduction, ecological as well as economic aspects of the used materials play an important role. For this purpose, the safety properties (impact resistance in case of tool breakage / collision) of these weight-reduced materials have to be determined. In addition, an improvement in the acoustic behaviour of the machine is achieved by the new lightweight materials since the machine enclosure shields the distinctive sound sources.
Źródło:
Journal of Machine Engineering; 2019, 19, 2; 46-53
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The possibility of application of the acoustic emission method for monitoring friction processes
Autorzy:
Dudzik, K.
Ziegler, B.
Powiązania:
https://bibliotekanauki.pl/articles/245247.pdf
Data publikacji:
2018
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
Acoustic Emission
AE
diagnostic
friction regimes
Opis:
This article presents the methodology and research results of monitoring friction processes between couple of cooperating elements by acoustic emission method. The research was carried out at the lathing machine test stand of the Technische Hochschule Mittelhessen. The test stand included lathing machine Proxon PD 210, shaft, made of austenitic stainless steel X2CrNi18-9 and steel plate, made of S235. The Friction process was monitored by an acoustic emission set made by Physical Acoustics Corporation (PAC). The PAC system includes: preamplifier USB AE Node, type 1283 with bandpass 20 kHz – 1 MHz, AE signal measurement sensor type VS 150M, with a frequency range 100-450 kHz, computer with AE Win for USB Version E5.30 software. During the study, the acoustic emission (AE) generated by friction between shaft and steel plate was recorded. The load of the plate was 0, 1, 2, 3, 4, 5 and 10 N. The following parameters were determined: amplitude, number of events – hits, the effective value of the signal (RMS). The use of grease between the cooperating elements caused a significant reduction in friction and thus the power of the generated signal (10 to 30 times). In the case of dry friction, without grease, the maximum RMS value was recorded at 4 N load and at the lubricant between the pair cooperating at 1 N load. The research has shown that it is possible to monitor the friction process between cooperating elements using the acoustic emission method.
Źródło:
Journal of KONES; 2018, 25, 2; 113-119
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the Acoustic Emission Method for Diagnosis of On-Load Tap Changer
Autorzy:
Majchrzak, H.
Cichoń, A.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/176624.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
transformer diagnostics
Opis:
This paper provides an example of the application of the acoustic emission (AE) method for the diagnosis of technical conditions of a three-phase on-load tap-changer (OLTC) GIII type. The measurements were performed for an amount of 10 items of OLTCs, installed in power transformers with a capacity of 250 MVA. The study was conducted in two different OLTC operating conditions during the tapping process: under load and free running conditions. The analysis of the measurement results was made in both time domain and time-frequency domain. The description of the AE signals generated by the OLTC in the time domain was performed using the analysis of waveforms and determined characteristic times. Within the time-frequency domain the measured signals were described by short-time Fourier transform spectrograms.
Źródło:
Archives of Acoustics; 2017, 42, 1; 29-35
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie metodą emisji akustycznej normalizowanych, hartowanych i wodorowanych próbek stalowych z karbem, podczas prób rozciągania. Efekt Kaisera
Stretching tests of standard hardened steel samples with a notch and after hydriding by the acoustic emission method - the Kaiser effect
Autorzy:
Łapiński, Z.
Łukaszewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/235050.pdf
Data publikacji:
2006
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
eksploatacja
emisja akustyczna
service
acoustic emission
Opis:
W artykule przedstawiono rezultaty badania metodą Emisji Akustycznej normalizowanych i hartowanych próbek stalowych z karbem oraz badanie efektu Kaisera.
The results of the tests carried out by the acoustic emission method on the hardened steel samples with a notch and the Kaiser effect results are presented in the paper.
Źródło:
Problemy Techniki Uzbrojenia; 2006, R. 35, z. 99; 129-142
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on Descriptors of Acoustic Emission Signals Generated by Partial Discharges under Laboratory Conditions and in On-Site Electrical Power Transformer
Autorzy:
Kunicki, M.
Cichoń, A.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/176881.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
transformer diagnostics
Opis:
An acoustic emission method (AE) is widespread and often applied for partial discharge (PD) diagnostics, mainly due to its ease of application as well as noninvasiveness and relatively high sensitivity. This paper presents comparative analysis of AE signals measurement results archived under laboratory conditions as well as on-site actual AE signals generated by inside PDs in electrical power transformer during its normal service. Three different PD model sources are applied for laboratory research: point to point, multipoint to plate and surface type. A typical measuring set up commonly used for on-site transformer PD diagnostics is provided for the laboratory tasks: piezoelectric joint transducer, preamplifier, amplifier and measuring PC interface. During the on-site research there are three measuring tracks applied simultaneously. Time domain, time-frequency domain and statistical tools are used for registered AE signals analysis. A number of descriptors are proposed as a result of the analysis. In the paper, attempt of AE signals descriptors, archived under laboratory condition application possibilities for on-site PD diagnostics of power transformers during normal service is made.
Źródło:
Archives of Acoustics; 2016, 41, 2; 265-276
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection and Recording of Acoustic Emission in Discrete IGBT Transistors
Autorzy:
Gordon, R.
Dreas, A.
Powiązania:
https://bibliotekanauki.pl/articles/2064954.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
IGBT Modules
IGBT Transistor
Acoustic Emission
Opis:
The article presents the results of experimental research, which is to show a correlation between the change of operating status of single IGBT transistor and its acoustic emission. Sensor signal was obtained with oscilloscope in order to further process it digitally and determine possibility of the damage to the element based on registered acoustic signal.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2018, 1, 1; 27--31
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surface evaluation during the grinding process using acoustic emission signal
Autorzy:
Sutowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/99909.pdf
Data publikacji:
2012
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
surface
roughness
grinding process
acoustic emission signal
Opis:
The hereby article presents results of experimental tests which prove the possibility of indirect evaluation of the grinded object's quality with the application of monitoring and analysis of selected acoustic emission signal (AE) registered during the machining process. As the grinding process is carried out and the grinding wheel wear progresses, the acoustic emission signal value is shaped adequately to the workpiece surface quality changes. The binding descriptor of changes of roughness profile and material residual stresses is the RMS value of the acoustic emission signal and in particular the statistical features that characterize the distribution of values contained in the signal sample in relation to the average value. The analysis results indicate that the acoustic emission signal is a convenient indicator for evaluation of stresses cumulated in the surface layer of the material and in selected surface geometrical structure parameters.
Źródło:
Journal of Machine Engineering; 2012, 12, 4; 23-34
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wytrzymałościowe zbiorników na sprężone powietrze z jednoczesnym pomiarem sygnałów emisji akustycznej (EA
Testing of mechanical strength of pressed air containers at simultaneous measurement of acoustic emission signals
Autorzy:
Łapiński, Z.
Powiązania:
https://bibliotekanauki.pl/articles/234796.pdf
Data publikacji:
2007
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
emisja akustyczna
zbiorniki powietrza
acoustic emission
tanks
Opis:
W artykule przedstawiono ogólną charakterystykę metody nieniszczącej polegającej na pomiarze sygnałów emisji akustycznej w trakcie obciążania badanego elementu i jej zastosowania do badań zbiorników na sprężone powietrze w czasie próby wytrzymałościowej.
The general description of a non-destructive testing method based on the measurement of acoustic emission signals at the same time when a tested device is under the working burden and its application for testing pressed air containers in the strength tests is presented in the paper. These waves are generated by some processes at the developing cracks, dislocations or mutual shifting and friction of internal fragments of material.
Źródło:
Problemy Techniki Uzbrojenia; 2007, R. 36, z. 104; 115-120
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The possibility of application the acoustic emission method for monitoring flow of water within a ball valve
Autorzy:
Dudzik, K.
Ziegler, B.
Powiązania:
https://bibliotekanauki.pl/articles/245518.pdf
Data publikacji:
2016
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
acoustic emission
AE
diagnostic
ball valve
cavitation
Opis:
Acoustic emission method (AE) can be used for the diagnosis of machine parts or apparatus such as, for example, ball valves. This paper presents the methodology and research results of ball valve in fresh water systems. The opening angle of the valve was changed during the research. The flow of water was measured by a magnetically inductive flowmeter. The research was carried out on a laboratory test stand using an acoustic emission set made by Vallen Inc. This set included: 4 channel signal recorder AMSY 6, two measurement modules ASIP-2/S, preamplifier with a frequency range 20 kHz – 1 MHz and the strengthening of 34 dB and AE signal measurement sensor type VS 150M, with a frequency range 100 – 450kHz. The obtained from the AE-System made by Vallen were compared with the results of the AE-System made by Physical Acoustics (PAC). The PAC system includes preamplifier USB AE Node, type 1283 with bandpass 20 kHz – 1 MHz, AE-Sensor R6D, computer with AE Win for USB Version E5.32 software. During the study, the acoustic emission (AE) generated by flowing water was recorded. The following parameters were determined: amplitude, number of events – hits, the effective value of the signal (RMS). Analysis of the results showed that within a specific range of opening angle of the valve the value of the generated acoustic emission in flowing water increases. This is probably associated with the occurrence of cavitation within the valve. This is an undesirable phenomenon and that these opening angles of ball valve should be avoided in the normal operation.
Źródło:
Journal of KONES; 2016, 23, 4; 87-92
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of Partial Discharges in Cable Insulation and Cable Head Using Acoustic Method
Autorzy:
Ranachowski, Zbigniew
Wieczorek, Krzysztof
Ranachowski, Przemysław
Dębowski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2141672.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
partial discharges
medium voltage insulation
acoustic emission
Opis:
The article presents the application of Acoustic Emission (AE) method for detection and registration of partial discharges (PD) generated in medium voltage (MV) cable isolation and MV cable head. The insulation of the high voltage cable is made of a flexible material whose properties are characterised by a high coefficient of attenuation of the acoustic signals. For this reason, the AE method has not been used so far to detect PD in energetic cables. The subjects of the research were the MV cable and the standard T-type cable head. The cable contained defects which were the source of partial discharges. In case of cable head the PD were provoked by thin grounded electrode which was introduced into connector opening. The results of AE measurements are presented in the form of spectrograms. Acoustic Emission was evoked when the applied voltage level reached the value of 7.5 kV for the cable and 4 kV for the cable head. The authors used the acoustic instrumentation of their own design intended for future field use. Obtaining successful results of partial discharges measurements using the acoustic method in the cable insulation makes an original contribution of the presented work.
Źródło:
Archives of Acoustics; 2022, 47, 2; 259-265
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the corrosion tester in corrosion tests using the acoustic emission method
Autorzy:
Emilianowicz, Krzysztof
Supernak, Milena
Ossowska, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/32912355.pdf
Data publikacji:
2022
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
corrosion
hull steels
acoustic emission
corrosion tester
Opis:
The article presents an innovative method of corrosion tests using the acoustic emission method and the corrosion tester. The problem of corrosion occurring in ballast tanks and tanks carrying petroleum products is discussed. The acoustic method is presented which, due to the use of a unique corrosion tester, is used to monitor the course of corrosion processes in steel. The principle of operation of the corrosion tester, its construction and its use in Non Destructive Testing (NDT) are described in detail. Corrosion test results, obtained with the use of a corrosion tester, are presented. An analysis and a short discussion of the obtained results are given. The results of both the acoustic and metallographic tests prove the possibility of detecting material damage occurring during the operation of the corrosion tester, allowing determination of the course and type of corrosion damage.
Źródło:
Polish Maritime Research; 2022, 3; 167-175
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Acoustic Emission as a Method for Analyzing Changes and Detecting Damage in Composite Materials During Loading
Autorzy:
Panasiuk, Katarzyna
Dudzik, Krzysztof
Hajdukiewicz, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/1945653.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
multilayered composite
recycling
mechanical properties
acoustic emission
Opis:
Thanks to their excellent strength and durability, composite materials are used to manufacture many important structural elements. In the face of their extensive use, it is crucial to seek suitable methods for monitoring damages and locating their origins. The purpose of the article was to verify the possibility of applying the acoustic emissions (AE) method in the detection of damages in the structures of composite materials. The experimental part comprised static tensile tests carried out on various sandwich composites, including simultaneous registration of elastic waves with increasing loads, carried out with the use of an acoustic-electrical sensor connected. The signal obtained from the sensor was then further processed and used to draw up diagrams of the AE hits, amplitude, root mean square of the AE source signal (RMS) and duration in the function of time. These diagrams were then applied on their corresponding stretching curves, the obtained charts were analysed. The results obtained point to a conclusion that the acoustic emissions method can be successfully used to detect and locate composite material damages.
Źródło:
Archives of Acoustics; 2021, 46, 3; 399-407
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of Rotor Damages of Three-Phase Induction Motors Using Acoustic Signals and SMOFS-20-EXPANDED
Autorzy:
Glowacz, A.
Powiązania:
https://bibliotekanauki.pl/articles/177944.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
induction motor
machine
acoustic signal
acoustic emission
fault diagnostics
Opis:
A fault diagnostics system of three-phase induction motors was implemented. The implemented system was based on acoustic signals of three-phase induction motors. A feature extraction step was performed using SMOFS-20-EXPANDED (shortened method of frequencies selection-20-Expanded). A classification step was performed using 3 classifiers: LDA (Linear Discriminant Analysis), NBC (Naive Bayes Classifier), CT (Classification Tree). An analysis was carried out for incipient states of three-phase induction motors measured under laboratory conditions. The author measured and analysed the following states of motors: healthy motor, motor with one faulty rotor bar, motor with two faulty rotor bars, motor with faulty ring of squirrel-cage. Measured and analysed states were caused by natural degradation of parts of the machine. The efficiency of recognition of the analysed states was good. The proposed method of fault diagnostics can find application in protection of three-phase induction motors.
Źródło:
Archives of Acoustics; 2016, 41, 3; 507-515
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies