Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "absorption dose" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Change of silica luminescence due to fast hydrogen ion bombardment
Autorzy:
Zhurenko, V. P.
Kalantaryan, O. V.
Kononenko, S. I.
Powiązania:
https://bibliotekanauki.pl/articles/146688.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
luminescent spectrum
absorption dose
ion implantation
silica
Opis:
This paper deals with the luminescence of silica (KV-type) induced by beam of hydrogen ions with the energy of 210 keV per nucleon. An average implantation dose of up to 3.5 × 1021 cm–3 (5 × 1010 Gy) was accumulated during irradiation over an extended period. The luminescent spectra consisted of the blue band (maximum at 456 nm) and the red band (650 nm) in the visible range. It was shown that increase in the absorption dose had an effect on the silica luminescence. It was found that the most significant changes in the spectrum occurred during the dose accumulation in the region of 550–700 nm. The shape of the spectrum of the luminescent radiation in this wavelength range was affected both by the oxygen deficient centres (blue band) and non-bridging oxygen hole centers (red band). Mathematical processing of the experimental spectra permitted to identify contributions to the luminescent radiation coming from both types of defects.
Źródło:
Nukleonika; 2015, 60, 2; 289-292
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the dose enhancement factor of high intensity low mono-energetic X-ray radiation with labeled tissues by gold nanoparticles
Autorzy:
Ranjbar, H.
Shamsaei, M.
Ghasemi, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/148638.pdf
Data publikacji:
2010
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radiation therapy
energy optimization
dose enhancement factor
dose absorption
gold nanoparticles
MCNPX code
Opis:
The aim of radiotherapy is to maximize the dose applied to the tumor while keeping the dose to the surrounding healthy tissue as low as possible. To further enhance dose to a tumor, techniques to radiosensitization of the tumor, using high atomic number elements, have been proposed. The aim of this study was to investigate the influence of using gold nanoparticles as a contrast agent on tumor dose enhancement when the tissue is irradiated by a typical mono energy X-ray beam. To improve the conventional radiotherapy enhancement of the absorbed dose in a tumor tissue and to spare the skin and normal tissues during irradiation in the presence of concentration agent, a model based on a Monte Carlo N-Particle eXtended (MCNPX) computer code has been designed to simulate the depth dose in a phantom containing an assumed tumor. Test was carried out in two phases. In phase 1, verification of this model using the MCNPX was evaluated by comparing the obtained results with those of the published reports. In phase 2, gold was introduced into assumed tumor inside the phantom at different depths in the simulation program. Simulation was performed for four different concentrations of gold nanoparticles using a low mono-energetic parallel beam of synchrotron radiation. The obtained results show that the optimum energy for dose enhancement is found to be around 83–90 keV for all gold concentrations. The dose enhancement factor is increased linearly with concentration and diminished in depth along the central beam in the tumor. This approach of introducing contrast agents in conventional radiotherapy could hopefully prepare new treatment planning and improve the efficiency of tumor therapy.
Źródło:
Nukleonika; 2010, 55, 3; 307-312
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przechodzenie cynku z naczyn i przedmiotów użytku do żywności
Pronikanie cinka v pishhu iz posudki i predmetov domashnego upotreblenija
The passing of zinc into foods from utensils and objects used for cooking and storing
Autorzy:
Kalinowska, R.
Powiązania:
https://bibliotekanauki.pl/articles/874598.pdf
Data publikacji:
1957
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
cynk
naczynia
blacha ocynkowana
przedmioty uzytku
kontakt z zywnoscia
wchlanianie cynku
przenikanie
zywnosc
zatrucia
dawki dopuszczalne
poziom cynku
szkodliwosc
zinc
absorption
dish
galvanized steel
food contact material
penetration
food
poisoning
acceptable dose
zinc level
harmfulness
Źródło:
Roczniki Państwowego Zakładu Higieny; 1957, 08, 5
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies