Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "X-ray microtomography" wg kryterium: Temat


Tytuł:
Osmotic dehydration and freezing as a suitable pretreatment in the process of vacuum drying kiwiberry: drying kinetics and microstructural changes
Autorzy:
Bialik, M.
Wiktor, A.
Witrowa-Rajchert, D.
Samborska, K.
Gondek, E.
Findura, P.
Powiązania:
https://bibliotekanauki.pl/articles/2082900.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
Actinidia arguta
X-ray microtomography
mathematical modelling
drying kinetics
Opis:
This study investigated the effects of osmotic dehydration and freezing on the kinetics and microstructure of vacuum-dried kiwiberry. Both fresh and previously frozen fruit were dehydrated in sucrose, maltitol and xylitol. Freezing and osmotic dehydration were selected as possible ways to improve the drying kinetics and positively influence the taste of the fruit. This experiment focused on the analysis of microstructural changes induced by applied processing methods using the X-ray microtomography technique. The results showed that the fruit pretreated in sucrose suffered the least structural damage as expressed by the largest condensation of small pores and thin cell walls. Freezing and xylitol resulted in the accumulation of larger pores and thicker walls. The most rapid drying time of 678-688 min was observed for unfrozen samples, dehydrated in sucrose and maltitol. Freezing slowed down the drying process, by 60-100 min, in comparison to the unfrozen samples. The applied mathematical models proved useful in predicting the kinetics of the drying process. The equation proposed by Midilli et al. provided the best fit for predicting the kinetics of the process.
Źródło:
International Agrophysics; 2020, 34, 2; 265-272
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Saurichthys (Pisces, Actinopterygii) teeth from the Lower Triassic of Spitsbergen, with comments on their stable isotope composition (δ13C and δ18O) and X−ray microtomography
Autorzy:
Błażejowski, Błażej
Duffin, Christopher J.
Gieszcz, Piotr
Małkowski, Krzysztof
Binkowski, Marcin
Walczak, Michał
McDonald, Samuel A.
Withers, Philip J.
Powiązania:
https://bibliotekanauki.pl/articles/2051411.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Arctic
Svalbard
fish teeth
stable isotopes
x−ray microtomography
Lower Triassic
Źródło:
Polish Polar Research; 2013, 1; 23-38
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray microtomography (XMT) of fossil brachiopod shell interiors for taxonomy
Autorzy:
Blazejowski, B.
Binkowski, M.
Bitner, M.A.
Gieszcz, P.
Powiązania:
https://bibliotekanauki.pl/articles/23513.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Instytut Paleobiologii PAN
Tematy:
x-ray microtomography
fossil
brachiopod
shell
taxonomy
remains
paleontology
Terebratula terebratula
Opis:
The ability to see and understand the three−dimensional structure of an investigated object plays a key role in studying fossil remains. All living organisms are formed in threedimensions, but unfortunately fossilization processes often reduce overall shape, making it difficult to gather information about real overall appearance, functionality, and inner structure. Here, using a specimen of the brachiopod Terebratula terebratula we demonstrate a non−destructive technique for exploring the 3−D internal structure of fossil remains. The use of tomography allows the construction of a set of transverse serial sections in the manner used by brachiopod researchers for decades.
Źródło:
Acta Palaeontologica Polonica; 2011, 56, 2
0567-7920
Pojawia się w:
Acta Palaeontologica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of the carbonation zone in concrete using X-ray microtomography
Autorzy:
Łydżba, D.
Rajczakowska, M.
Stefaniuk, D.
Kmita, A.
Powiązania:
https://bibliotekanauki.pl/articles/178832.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
concrete
carbonation zone
X-ray microtomography
beton
strefa karbonatyzacji
mikrotomografia rentgenowska
Opis:
The article presents an application of X-ray microtomography for identification of the carbonation zone in concrete material. A concrete specimen subjected earlier to harsh environmental conditions is investigated. The material is firstly checked with the use of chemical corrosion indicators and then is subjected to microstructural analysis performed with the use of X-ray microtomography. Two different settings of scanning parameters are applied implying the image resolutions of approximately 14 μm per 1 pixel and about 7 μm per 1 pixel, respectively. The results obtained are then compared and analyzed. The depth of the carbonation zone is evaluated based on the attenuation curve. The paper highlights also the significance of the corrosion phenomenon in concrete structures. Details of the deterioration mechanisms in concrete are shortly presented.
Źródło:
Studia Geotechnica et Mechanica; 2014, 36, 1; 47-54
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray microtomography (μCT) as a useful tool for visualization and interpretation of shear strength test results
Autorzy:
Stefaniuk, D.
Tankiewicz, M.
Stróżyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/178870.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
X-ray microtomography
shear strength
shear plane
fine-grained soil
triaxial test
Opis:
The paper demonstrates the applicability of X-ray microtomography (μCT) to analysis of the results of shear strength examinations of clayey soils. The method of X-ray three-dimensional imaging offers new possibilities in soil testing. The work focuses on a non-destructive method of evaluation of specimen quality used in shear tests and mechanical behavior of soil. The paper presents the results of examination of 4 selected clayey soils. Specimens prepared for the triaxial test have been scanned using μCT before and after the triaxial compression tests. The shear strength parameters of the soils have been estimated. Changes in soil structure caused by compression and shear failure have been presented as visualizations of the samples tested. This allowed for improved interpretation and evaluation of soil strength parameters and recognition of pre-existing fissures and the exact mode of failure. Basic geometrical parameters have been determined for selected cross-sections of specimens after failure. The test results indicate the utility of the method applied in soil testing.
Źródło:
Studia Geotechnica et Mechanica; 2014, 36, 4; 47-55
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda pomiaru gęstości osadu pokoagulacyjnego z zastosowaniem tomografii rentgenowskiej
Measurement method of sediment densities after coagulation using x-ray tomography
Autorzy:
Rząsa, M. R.
Podgórni, E.
Powiązania:
https://bibliotekanauki.pl/articles/268323.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
gęstość osadu
koagulacja
mikrotomografia rentgenowska
density of sediment
coagulation
X-ray microtomography
Opis:
Koagulacja jest jednym z procesów oczyszczania wody. Polega na destabilizacji układu koloidalnego i aglomeracji cząstek, które następnie usuwa się w procesach sedymentacji, flotacji czy filtracji. Powstałe cząstki pokoagulacyjne charakteryzują się zróżnicowanym kształtem, wielkością oraz strukturą. Szybkość opadania takich cząstek w dużej mierze zależy od ich gęstości. Struktura cząstek powoduje, że wyróżnia się dwa rodzaje porów. Makropory, które nie powinny być uwzględniane przy wyznaczaniu gęstości oraz mikropory, które stanowią cechę charakteryzującą dany osad pokoagulacyjny. Gęstość wyznaczono metodą wagową dla odpowiednio przygotowanych próbek. Ponieważ proces prasowania może niszczyć mikrostrukturę osadu, przeprowadzono badania mające na celu określenie stopnia sprasowania próbek, aby zminimalizować błędy wyznaczenia gęstości. Badania te prowadzono za pomocą tomografu rentgenowskiego, dzięki któremu możliwe było wyznaczenie objętości danej próbki z korektą makroporowatości. W pracy przedstawiono wyniki badań oraz parametry graniczne procesu przygotowywania próbek.
Coagulation is one of the processes of water purification, which consists in the destabilization of the dispersion and agglomeration of the particles, which are removed in the process of sedimentation, flotation or filtration. After the coagulation particles have a varied shape, size and porous structure. The rate of descent of such particles largely depends on their density. The structure of the particles causes two types of pores. Macropores that should not be taken into account when determining the density, and micropores, which are a characteristic feature of the sediment after coagulation process. To determine the density of sludge samples were subjected to compression, in order to eliminate the macropores and then, after designation of sample volume, density was determined by weighing. The precipitate was prepared based on a prepared water model, to which was added a coagulant Flokor 1.2A. The precipitate was filtered on a cellulose filter, and then subjected to a drying process. The dry sludge was pressed on the press impact. Because of the pressing process can destroy the microstructure of the sediment, studies have been conducted to determine the degree of compression of samples to minimize errors while determine the density. These studies were carried out using X-ray tomography, it was possible to designate the volume of the sample while subtraction residues macropores. For the correct determination of the volume, determination the correct number of threshold is necessary, based on which is possible to qualify individual pixels. In order to clearly identify which pixels represent sediment, it was necessary to carry out the image processing. That process were performed using LabVIEW software and Vision module. The paper presents results of research for density measurement and sets limits for the sample preparation process.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 159-162
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-invasive analysis and visualization of objects from FSW AlSi9Mg/2017A aluminum alloy joints
Nieinwazyjna analiza i wizualizacja obiektów w złączach AlSi9Mg/2017A wytwarzanych metodą Friction Stir Welding
Autorzy:
Wójcicka, A.
Mroczka, K.
Kowalski, M.
Powiązania:
https://bibliotekanauki.pl/articles/264301.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
X-ray microtomography
image analysis
aluminum alloys
FSW
mikrotomografia komputerowa
analiza obrazów
stopy aluminium
Opis:
Friction stir welding (FSW) technology allows for the welding of materials that differ in their chemical compositions, microstructures, and properties. When selecting the parameters, it is necessary to analyze the structure of a weld and eliminate the defects. The use of X-ray microtomography creates the possibility of precise imaging of a joint structure – especially when it contains defects (voids). The tests were carried out on an FSW joint made with both 2017A and AlSi9Mg aluminum alloys. The macrostructure was cross-sectional, and a defect was found in the middle part of the joint and on the advancing side. We used a conventional method of observation light microscopy. Then, an analysis was performed using X-ray microtomography, which revealed the shape of the defect in 3D. Individual cross-sections were extracted, which enabled us to measure the geometric quantities. A dependence was found for the shape of the defect on the welding parameters and the variability of its construction. The usefulness of this advanced material imaging technology for the analysis of FSW welds has been confirmed.
Technologia FSW umożliwia zgrzewanie materiałów różniących się składem chemicznym, mikrostrukturą i właściwościami. Przy doborze parametrów konieczna jest analiza struktury złącza i eliminacja ewentualnych wad. Zastosowanie mikrotomografii komputerowej umożliwia precyzyjne obrazowanie budowy złącza, szczególnie gdy zawiera wady (pustki). Badania przeprowadzono na złączu FSW stopów aluminium 2017A i AlSi9Mg. Zbadano makrostrukturę na przekroju poprzecznym i stwierdzono obecność wady w środkowej części złącza i po stronie natarcia. Zastosowano konwencjonalną metodę obserwacji – mikroskopię świetlną. Następnie wykonano analizę złącza z zastosowaniem tomografii komputerowej, która ujawniła kształt wady w wymiarze 3D. Wyekstrahowano poszczególne przekroje, które umożliwiły wykonanie pomiarów wielkości geometrycznych. Stwierdzono zależność kształtu wady od parametrów zgrzewania oraz zmienność jej budowy. Potwierdzono przydatność tej zaawansowanej technologii obrazowania budowy materiałów do analizy złącz FSW.
Źródło:
Metallurgy and Foundry Engineering; 2018, 44, 3; 145-152
1230-2325
2300-8377
Pojawia się w:
Metallurgy and Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przestrzenne badanie systemu porowego skał węglanowych na podstawie cyfrowej analizy obrazów mikrotomograficznych z wykorzystaniem języka Python
Spatial analysis of carbonate pore system based on digital image analysis of X-ray microtomography data using Python language
Autorzy:
Fheed, Adam
Hadro, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2076181.pdf
Data publikacji:
2021
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
mikrotomografia rentgenowska
Phyton
węglanowe skały zbiornikowe
porowatość
X-ray microtomography
Python
carbonate reservoir rocks
porosity
Opis:
The main aim of this contribution is to combine a Python-supported analysis of X-ray microtomography (µCT) images and the transmitted-light microscopy to resolve the factors controlling the variability of petrophysical parameters in carbonate rocks. A self-developed Python script for the evaluation of pore connectivity and the computation of pore sizes based on µCT data was prepared. The script was launched on a carbonate sample with drawn from a drill core representing the Late Permian Zechstein Limestone (Ca1) formation from the Wolsztyn Ridge area in West Poland. The sample was taken from the upper part of the isolated Kokorzyn Reef, corresponding to a brachiopod and bivalve-rich zone. The plug had a cylindrical shape, the diameter of 2.54 cm and the height of approximately 4.6cm. The entire volume of the plug was scanned using a GE Nanotom Sdevice. The 3D-reconstructeddatasetobtainedwith spatial resolution of 0.02 mm underwent cropping, contrast adjustment, noise reduction and porosity extraction using open-source Fiji software. The binarized porosity image was loaded into the Python script. Python scripting was found efficient in carbonate pore system examination. The code first extracted the connected pore system of the largest volume and computed the smallest distances between porosity voxels and corresponding pore walls. The obtained results were confronted with the spatially-adjusted microphotographs taken in plane-polarized transmitted light. The results have shown that narrow and isolated pores occurred within the spines of brachiopods. The largest voids were found inside the brachiopod shells. Moreover, many pores were associated with partially dissolved fragments of bivalves. Porosity reduction was -most outlined in the zones showing the scarcity of fossils.
Źródło:
Przegląd Geologiczny; 2021, 69, 6; 357--360
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Morphology and surface topography of Ti6Al4V lattice structure fabricated by selective laser sintering
Autorzy:
Maszybrocka, J.
Stwora, A.
Gapiński, B.
Skrabalak, G.
Karolus, M.
Powiązania:
https://bibliotekanauki.pl/articles/202149.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
metal porous implant
selective laser sintering
surface roughness
X-ray microtomography
selektywne spiekanie laserowe
chropowatość powierzchni
Mikrotomografia
Opis:
Construction of metallic implants with a porous structure that mimics the biomechanical properties of bone is one of the challenges of orthopedic regenerative medicine. The selective laser sintering technique (SLS) allows the production of complex geometries based on three-dimensional model, which offers the prospect of preparing porous metal implants, in which stiffness and porosity can be precisely adjusted to the individual needs of the patient. This requires an interdisciplinary approach to design, manufacturing and testing of porous structures manufactured by selective sintering. An important link in this process is the ability to assess the surface topography of the struts of porous structure. The paper presents a qualitative assessment of the surface morphology based on SEM studies and methodology that allows for quantitative assessment of stereometric structure based on micro-tomographic measurements.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 1; 85-92
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problem of the objects detection on low quality 3D image – example solution
Autorzy:
Gądek-Moszczak, A.
Powiązania:
https://bibliotekanauki.pl/articles/114988.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
image processing
low contrast
noise
X-ray microtomography
przetwarzanie obrazu
hałas
mikrotomografia rentgenowska
redukcja szumów
poprawa kontrastu
Opis:
Precise detection of analyzed objects is crucial and the most important task in quantitative and qualitative image of the microstructure analysis. The most common image distortion is noise, artefacts and low contrast. In the paper, author on the example of poor quality image of the polyurethane-polystyren composite structure, obtained with the X-ray microtomograph, presented possible methods of noise reduction, contrast enhancement, and correction of detection errors on the binary image.
Źródło:
Zeszyty Naukowe. Quality. Production. Improvement; 2017, 1 (6); 134-141
2544-2813
Pojawia się w:
Zeszyty Naukowe. Quality. Production. Improvement
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Struktura wewnętrzna i geneza współczesnej pokrywy solnej solniska Salar de Uyuni (Boliwia) w świetle badań tomograficznych
Internal structure and origin of modern salt crust of Salar de Uyuni (Bolivia) salt pan based on tomographic research
Autorzy:
Burliga, S.
Dohnalik, M.
Powiązania:
https://bibliotekanauki.pl/articles/183455.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
Salar de Uyuni
współczesne osady solne
poligony z wysychania
mikrotomografia rentgenowska
modern salt deposits
desiccation polygons
X-ray microtomography
Opis:
W pracy przedstawiono rezultaty badań budowy wewnętrznej współczesnej pokrywy solnej solniska Salar de Uyuni w południowo-zachodniej Boliwii. Analizie poddano również budowę wypełnień szczelin z wysychania. Podstawową techniką badawczą była mikrotomografia rentgenowska, obrazująca pełną strukturę wewnętrzną prób bez ich destrukcji. Badania wykazały trójdzielność struktury pokrywy: obecność powłoki halitowej na powierzchni, warstwy halitytów komórkowych poniżej powłoki oraz warstwy halitytów wielkoporowych w części spągowej pokrywy. Szczeliny z wysychania wypełniają halityty pęcherzykowate. Rozmieszczenie materiału mułowego w próbie oraz rozmycia kryształów przypowierzchniowych wskazują na wielokrotność cykli rozpuszczania soli, krystalizacji halitu i depozycji mułów. Na tej podstawie sformułowano wniosek, iż obserwowane w skałach warstwowanie nie odzwierciedla rocznych cykli sedymentacyjno-ewaporacyjnych, lecz cykle wieloletnie. Tłumaczy to niskie średnie tempo przyrostu osadów na solnisku.
This paper presents the results of a study on the internal structure of modern salt crust of Salar de Uyuni in SW Bolivia. Additionally, the structure of desiccation fissure infill was investigated. X-ray microtomography was used as the main analytical method because it enabled the complete structure of the sample's interior to be imaged without its destruction. Based on microtomographic images three layers were distinguished in the crust between the surface and its base: a halite shell at the top, a cellular halite layer in the middle and a large-pore halite layer at the base. Results revealed that the desiccation fissures are filled with extremely porous bubble-halite. Distribution of mud in the sample as well as wash-out of the surfical halite crystals indicate the cyclicity of halite dissolution, its crystallisation and mud accumulation. These observations provide an explanation for low rate salt accumulation in the salt pan. This leads to the conclusion that the observed layering in the rocks does not reflect annual sedimentation-evaporation cycles but rather long-term cycles.
Źródło:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2011, 37, 2; 215-229
0138-0974
Pojawia się w:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of the tension and compression behavior of sintered 316L using micro computed tomography
Autorzy:
Doroszko, M.
Seweryn, A.
Powiązania:
https://bibliotekanauki.pl/articles/387023.pdf
Data publikacji:
2015
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
finite element method
X-ray microtomography
porous materials
mechanical properties
plasticity
metoda elementów skończonych (MES)
mikrotomografia rentgenowska
materiały porowate
plastyczność
właściwości mechaniczne
Opis:
This paper describes the method of numerical modeling of the tension and compression behavior of sintered 316L. In order to take into account the shape of the mesostructures of materials in the numerical modeling, X-ray microtomography was used. Based on the micro-CT images, three-dimensional geometrical models mapped shapes of the porosity were generated. To the numerical calculations was used finite element method. Based on the received stress and strain fields was described the mechanism of deformation of the materials until fracture. The influence of material discontinuities at the mesoscopic scale on macromechanical properties of the porous materials was investigated.
Źródło:
Acta Mechanica et Automatica; 2015, 9, 2; 70-74
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nieinwazyjne metody analizy instrumentalnej w nowoczesnej technologii farmaceutycznej
Non-invasive instrumental analytical methods in modern pharmaceutical technology
Autorzy:
Ronowicz, Joanna
Piekuś-Słomka, Natalia
Powiązania:
https://bibliotekanauki.pl/articles/762683.pdf
Data publikacji:
2020-04-27
Wydawca:
Polskie Towarzystwo Farmaceutyczne
Tematy:
spektroskopia w zakresie podczerwieni
impulsowa spektroskopia terahercowa
spektroskopia Ramana
obrazowanie ramanowskie
mikrotomografia rentgenowska
Raman spectroscopy
infrared spectroscopy
X-ray microtomography
pulse terahertz spectroscopy
Raman imaging
Opis:
The purpose of this work is the evaluation of the state of knowledge in the scope of the possibility of using of non-invasive analytical methods in the implementation of Process Analytical Technology strategy, which is currently recommended by worldwide registration agencies. The drug product quality should be based on risk analysis. Effective risk management is possible through the implementation of innovative process analysis technology (PAT strategy). The pursuit of an efficient production control system makes non-invasive techniques particularly important. These techniques provide the ability to monitor each stage of the manufacturing process, and thus identify defects during the manufacture of drug dosage forms. The infrared spectroscopy, Raman spectroscopy and pulsed terahertz spectroscopy are gaining in importance. Research articles describe the application of Raman imaging, scanning electron microscopy or atomic force microscopy in the evaluation of pharmaceutical formulations. These methods facilitate making accurate technological decisions that guarantee the desired drug product quality. The need to adapt to current regulations and recommendations of regulatory authorities in the field of process control systems forces the search for new analytical methods allowing for the collection of process data in real-time. In recent years, innovative instrumental analytical methods such as optical coherence tomography, X-ray microtomography and microwave resonance have gained popularity. In comparison to the traditional approach to the drug product quality assurance, the PAT strategy assumes a holistic approach by integrating the manufacturing process with simultaneous control of all production stages. It seems extremely important to automate the manufacturing process control so that it is carried out without interrupting production as part of so-called continuous process verification. Due to a better process understanding and accurate identification of sources of variation in the manufacturing process, the implementation of PAT strategy seems to be necessary to obtain the desired drug product quality in a repeatable manner. The principle of continuous process and product quality improvement focuses on reducing the manufacturing process variability by continuous process monitoring using non-invasive and non-destructive instrumental analytical methods.
Celem pracy jest przybliżenie stanu wiedzy w zakresie możliwości wykorzystania nieinwazyjnych metod analitycznych w realizacji strategii PAT (ang. Process Analytical Technology), która jest obecnie rekomendowana przez światowe agencje rejestracyjne. Dążenie do uzyskania sprawnego systemu kontroli procesu wytwarzania sprawia, że na znaczeniu zyskują szczególnie techniki nieinwazyjne stwarzające możliwość monitorowania poszczególnych etapów procesu technologicznego, a tym samym szybkiej identyfikacji defektów powstających podczas wytwarzania postaci leku. Na znaczeniu zyskuje spektroskopia w zakresie podczerwieni, spektroskopia Ramana czy impulsowa spektroskopia terahercowa. W literaturze opisywane są przykłady wykorzystania obrazowania ramanowskiego, skaningowej mikroskopii elektronowej czy mikroskopii sił atomowych w ocenie formulacji farmaceutycznych. Konieczność dostosowania się do aktualnych regulacji oraz zaleceń organów rejestracyjnych w zakresie systemów kontroli procesów wytwarzania wymusza poszukiwanie nowych metod analitycznych pozwalających na zbieranie danych procesowych w czasie rzeczywistym. W ostatnich latach popularność zdobywają nowatorskie metody analizy instrumentalnej, jak optyczna tomografia koherencyjna, mikrotomografia rentgenowska czy rezonans mikrofalowy. W odróżnieniu od tradycyjnego podejścia do problemu zapewnienia jakości produktu leczniczego, strategia PAT zakłada holistyczne podejście do procesu wytwarzania poprzez zintegrowanie procesu wytwarzania z jednoczesną kontrolą wszystkich etapów produkcyjnych. Niezwykle istotna wydaje się być automatyzacja procesu kontroli, tak by była ona prowadzona bez przerywania produkcji w ramach ciągłej weryfikacji procesu (ang. continuous process verification). Zasada ciągłego doskonalenia procesu i produktu koncentruje się na redukcji zmienności procesu wytwarzania poprzez ciągłe jego monitorowanie przy użyciu nieinwazyjnych i niedestrukcyjnych metod analizy instrumentalnej.
Źródło:
Farmacja Polska; 2020, 76, 3; 163-169
0014-8261
2544-8552
Pojawia się w:
Farmacja Polska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heterogeneous pores distribution in polyurethane expanding foams detected via X-ray computed microtomography
Niejednorodność rozkładu porów w ekspandujących piankach poliuretanowych obserwowana metodą mikrotomografii komputerowej
Autorzy:
Blażejczyk, A.
Wierzbicka, P.
Powiązania:
https://bibliotekanauki.pl/articles/947301.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
rentgenowska mikrotomografia komputerowa
obrazowanie pianki
pianki poliuretanowe
pory
więzadła
X-ray computed microtomography
foam imaging
polyurethane foams
pores
struts
Opis:
X-ray computed microtomography (μ-CT) was applied as a noninvasive three-dimensional (3D) imaging technique for characterization of solid cellular material microstructure. Comparison between morphologies of two versions (summer and winter) of polyurethane (PUR) expanding foam (commercially available as the one-component 1K hand-held foams, applicable in building sector) was done. The evident relationship between processing and microstructure was explained. The most significant morphometric parameters were obtained via quantitative and qualitative 3D microstructure μ-CT analysis. The analysis embraced computing: dimensions of the selected structural elements (struts or pores), the average surface areas and volumes either of solid matrix or pores (open and close), as well as porosity assessment. The pores diameters (structure separation) statistical distributions were found and resulted as heterogeneous for both PUR versions, as revealed via proposed Gaussian μ-CT data analysis (“double Gauss” model).
Do charakterystyki mikrostruktury materiału komórkowego zastosowano rentgenowską mikrotomografię komputerową (µ-CT) – nieinwazyjną technikę obrazowania trójwymiarowego (3D). Porównano morfologie dwóch wersji (letniej i zimowej)pianki poliuretanowej (PUR), dostępnej w handlu w postaci jednoskładnikowej ekspandującej pianki typu 1K do zastosowań w budownictwie. Omówiono zaobserwowaną zależność między technologią przetwarzania a mikrostrukturą pianki. Na podstawie ilościowej i jakościowej mikrotomograficznej analizy trójwymiarowej mikrostruktury, obejmującej obliczenia wymiarów podstawowych elementów struktury (więzadeł i porów), a także powierzchni i objętości matrycy stałej i porów (otwartych i zamkniętych), wyznaczono najistotniejsze parametry morfometryczne. Dokonano też oceny porowatości pianki. Rozkłady średnic porów (structure separation) uzyskane w wyniku zaproponowanej gaussowskiej analizy danych mikrotomograficznych (double Gauss model) okazały się niejednorodne w wypadku obu wersji pianek PUR.
Źródło:
Polimery; 2018, 63, 10; 685-693
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis and Characterization of Co-Cs-Nd-Sr-Doped Perovskite-Rutile-Type Structure
Autorzy:
Smolinski, T.
Zhao, L.
Rogowski, M.
Wawszczak, D.
Olczak, T.
Brykala, M.
Powiązania:
https://bibliotekanauki.pl/articles/355628.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Synroc
X-ray diffraction
Rutherford backscattering
particle induced X-ray emission
Roentgen computed microtomography
Opis:
The perovskite type matrix is considered as solidification material for high-level radioactive waste. In this work the perovskite-rutile-type matrix doped by Co, Cs, Nd and Sr which simulate nuclear waste was prepared by sol-gel route. The material was characterized by several methods such as: X-ray diffraction, energy dispersive X-ray spectrometer, and particle induced X-ray emission combined with Rutherford backscattering spectrometry. The analyzes confirmed chemical composition Co-Cs-Nd-Sr-doped perovskite-rutile-type structure. A virtual model of the pellet`s structure was created non-destructively by Roentgen computed micro-tomography. The leaching tests confirmed high chemical resistance of the matrix.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 4; 1417-1423
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies