Tytuł:
Stabilization of multi DC bus link voltages of multilevel NPC VSI. Application to double stator induction motors
Autorzy:
Beriber, D.
Talha, A.
Boucherit, M. S.
Powiązania:
https://bibliotekanauki.pl/articles/229769.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multilevel
VSI
NPC
PWM
rectifier
clamping bridge
Opis:
Voltage source multilevel inverters have become very attractive for power industries in power electronics applications during last years. The main purposes of studying multilevel inverters are the generation of output voltage signals with low harmonic distortion and reduction of switching frequency. An important issue of the multilevel inverter is the capacitor voltage-balancing problem. The unbalance of different DC voltage sources of multilevel neutral point clamped (NPC) voltage source inverter (VSI) constitutes the major limitation for the use of this new power converter. In this paper, we present study on the stability problem of the input DC voltages of the three-level Neutral Point Clamping (NPC) voltage source inverter (VSI). This inverter is useful for application in high voltage and high power area. In the first part, we remind the model of double stator induction motors (DSIM). Then, we develop control models of this inverter using the connection functions of the semi-conductors. We propose a Pulse Width Modulation (PWM) strategy to control this converter. The inverter is fed by constant input DC voltages. In the last part, we study the stability problem of the input DC voltages of the inverter. A cascade constituted by two three-level PWM rectifiers - two three-level NPC VSI - DSIM is discussed. The results obtained show that the input DC voltages of the inverters are not stable. To solve this problem, we propose to use a half clamping bridge. This solution is very promising in order to stabilize the input DC voltages of this converters.
Źródło:
Archives of Control Sciences; 2012, 22, 1; 107-120
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PMSM drive based on STM32F4 microcontroller
Autorzy:
Skiwski, M.
Tarczewski, T.
Grzesiak, L. M.
Powiązania:
https://bibliotekanauki.pl/articles/376821.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
PMSM
drive
STM32F4
VSI
FOC
Opis:
In this paper based on STM32F4 microcontroller and dedicated for permanent magnet synchronous motor (PMSM) drive is presented. Information concern structure and implementation of the program main blocks such as: modulator, speed and position calculation, communication interface are depicted. Designing process of cascade control structure with PI controllers is shown. An internal model control (IMC) was used to calculate coefficients of current controllers while the symmetric optimum criterion was applied to compute angular speed controller. Since mathematical model of the drive is non-linear, linearization and decoupling procedure as well as dead-time compensation are also included. Finally, experimental test results for PMSM with FOC control algorithm are shown.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 87; 377-387
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Control of squirrel-cage electric generators in a parallel intermediate DC circuit connection
Autorzy:
Kozak, M.
Gordon, R.
Bejger, A.
Powiązania:
https://bibliotekanauki.pl/articles/135529.pdf
Data publikacji:
2016
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
back-to-back
DC link
power distribution
VSI
FOC
power machine
Opis:
The paper covers the theoretical background and tests of two asynchronous squirrel cage generators connected to voltage source inverters working in parallel. Inverters were connected in parallel by their intermediate direct current circuits by means of auctioneering diodes, and then to a DC power network. The real-time control algorithm of digital signal processor DSP and field-programmable gate array FPGA was used to achieve proper excitation of two different power machines, and to maintain high enough levels of direct current link voltage. Windings of both generators are fed by use of so-called machine side inverters. The asynchronous generator is a voltage source inverter controlled by a field-oriented control algorithm based on the current machine model. To prove robustness of the chosen algorithm, different types of load were applied while generators and inverters worked in parallel.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2016, 45 (117); 17-22
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new closed loop speed control strategy for a vector controlled three-phase induction motor drive
Autorzy:
Tripathi, A.
Dey, A.
Dwivedi, B.
Singh, B.
Chandra, D.
Powiązania:
https://bibliotekanauki.pl/articles/262777.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
space vector modulation
VSI
induction motor model
transients
steady state value
Opis:
This paper presents a completely mathematical equations based model on control of torque and speed of a three-phase indirect vector controlled VSI fed cage induction motor drive that is controlled through the space vector modulated method. This enables a wide range of acceptability of the model for various values of load and for various types and ratings of induction motors. The uniqueness of the model lies in the fact that the deviations in the torque and speed on sudden application of reference step change in speed values are minimum i.e. when any sudden change in the speed reference is desired, the speed and torque waveforms reveal that the time taken in coming back to their final steady state values is very less and the motor overcomes the perturbation with negligible transients. The same is verified through the simulated results.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2008, 14, 1; 67-72
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel circuit topology of modified switched boost hybrid resonant inverter fitted induction heating equipment
Autorzy:
Bhattacharya, A.
Sit, K.
Sadhu, P. K.
Pal, N.
Powiązania:
https://bibliotekanauki.pl/articles/140770.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
modified switched boost
high frequency
hybrid resonant inverter
induction heating
controllability
VSI and PSIM
Opis:
A novel circuit topology of modified switched boost high frequency hybrid resonant inverter fitted induction heating equipment is presented in this paper for efficient induction heating. Recently, induction heating technique is becoming very popular for both domestic and industrial purposes because of its high energy efficiency and controllability. Generally in induction heating, a high frequency alternating magnetic field is required to induce the eddy currents in the work piece. High frequency resonant inverters are incorporated in induction heating equipment which produce a high frequency alternating magnetic field surrounding the coil. Previously this high frequency alternating magnetic field was produced by voltage source inverters. But VSIs have several demerits. So, in this paper, a new scheme of modified switched boost high frequency hybrid resonant inverter fitted induction heating equipment has been depicted which enhances the energy efficiency and controllability and the same is validated by PSIM.
Źródło:
Archives of Electrical Engineering; 2016, 65, 4; 815-826
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Constant switching frequency predictive control scheme for three-level inverter-fed sensorless induction motor drive
Autorzy:
Stando, D.
Kazmierkowski, M. P.
Powiązania:
https://bibliotekanauki.pl/articles/200480.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
model predictive control MPC
induction motor (IM)
direct torque and flux control (DTFC)
sensorless control
MRAS
three-level VSI
Opis:
The paper presents a novel model predictive flux control (MPFC) scheme for three-level inverter-fed sensorless induction motor drive operated in a wide speed region, including field weakening. The novelty of the proposed drive lies in combining in one system a number of new solutions providing important features, among which are: very high dynamics, constant switching frequency, no need to adjust weighting factors in the predictive cost function, adaptive speed and parameter (stator resistance, main inductance) estimation. The theoretical principles of the optimal switching sequence predictive stator flux control (OSS-MPFC) method used are also discussed. The method guarantees constant switching frequency operation of a three-level inverter. For speed estimation, a compensated model reference adaptive system (C-MRAS) was adopted while for IM parameters estimation a Q-MRAS was developed. Simulation and experimental results measured on a 50 kW drive that illustrates operation and performances of the system are presented. The proposed novel solution of a predictive controlled IM drive presents an attractive and complete algorithm/system which only requires the knowledge of nominal IM parameters for proper operation.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 5; 1057-1068
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies