Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Tubes" wg kryterium: Temat


Tytuł:
Research on inner surface of hydroformed tubes
Autorzy:
Ceclan, V. A.
Grozav, S. D.
Kuric, I.
Powiązania:
https://bibliotekanauki.pl/articles/102205.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
surface
hydroforming
tubes
Opis:
In this paper a reserch regarding the surfece of hydroforming tubs, made by aluminium and cooper is presented. Tube hydroforming is very important production method considering that metal tubes are widely used in a great variety of engineering products, such as automobile, aircraft, air conditioner, air compressor, exhaust systems, fluid lines. The results show that the surface of tubes it is influence of the hydroforming process. the material of the tube in research of surface is also very important.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 311-317
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niejednorodność własności mechanicznych ciągnionych rur kwadratowych
Heterogeneity of mechanical properties of drawn square tubes
Autorzy:
Oczkowicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/395260.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
rury profilowe
ciągnienie rur
własności mechaniczne
tubes profile
tubes drawing
mechanical properties
Opis:
W artykule omówiono zalety i zastosowanie rur kwadratowych oraz proces ciągnienia badanych rur. Z kolei przedstawiono wyniki badań własności mechanicznych tych rur. Badano następujące własności mechaniczne materiału rur kwadratowych: umowna granica sprężystości R0,05, umowna granica plastyczności R0,2, wytrzymałość na rozciąganie Rm, naprężenie rozrywające Ru, wydłużenie A10, wydłużenie równomierne Ar, przewężenie Z, a także zapas plastyczności R0,2/Rm oraz twardość Vickersa HV5. Własności mechaniczne określone w statycznej próbie rozciągania badano na próbkach wyciętych w takich miejscach charakterystycznych przekroju rury kwadratowej jak naroża i środki długości płaskich ścianek, natomiast twardość badano na przekrojach poprzecznych rur w analogicznych miejscach charakterystycznych jak wyżej i ponadto w płaskich ściankach w pobliżu naroży, przy czym badania twardości prowadzono w trzech warstwach na grubości ścianki rury: w warstwie przyzewnętrznej, w warstwie środkowej i w warstwie przywewnętrznej. Stwierdzono znaczącą niejednorodność własności w badanych miejscach charakterystycznych rur. Stwierdzono również prawidłowości w rozkładach twardości w miejscach charakterystycznych w badanych warstwach ścianek rur.
The article discusses the advantages and application of square tubes and the process of drawing steel tubes. In addition results of investigation of mechanical properties of these tubes are presented. Following mechanical properties of square tubes were studied: conventional elastic limit R0,05, conventional yield point R0,2, tensile strength Rm, breaking stress Ru, elongation A10, uniform elongation Ar, contraction of area Z, and store of plasticity R0,2/Rm, and Vickers hardness HV5. The mechanical properties specified in the static tensile test was studied on samples cut out in such specific section of the pipe as square corners and measures the length of flat faces, while the hardness was examined on cross sections of tubes in the same places as above and also in the flat walls near the corners, while hardness testing was performed in three layers on the pipe cross wall thickness: the outer layer, in the middle layer and the inner layer. It was also found in the pattern of distributions of hardness in specific locations in the tested tube wall layers.
Źródło:
Postępy Nauki i Techniki; 2010, 5; 145-155
2080-4075
Pojawia się w:
Postępy Nauki i Techniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of tracheostomy tube degradation processes using scanning microscopy and X-ray spectrometry in patients following ENT surgery
Ocena procesów degradacji rurek tracheostomijnych przy użyciu metod mikroskopii skaningowej i spektrometrii rentgenowskiej u pacjentów po zabiegach laryngologicznych
Autorzy:
Smółka, Wojciech
Chmiela, Bartosz
Pilch, Jan
Likus, Wirginia
Markowski, Jarosław
Wojtysiak, Alicja
Sozańska, Maria
Powiązania:
https://bibliotekanauki.pl/articles/41152846.pdf
Data publikacji:
2023
Wydawca:
Wydawnictwo SIGMA-NOT
Tematy:
tracheostomy tubes
deterioration of tracheostomy tubes
rurki tracheostomijne
niszczenie rurek tracheostomijnych
Opis:
Tracheostomy tubes are commonly used not only in emergencies involving airflow obstruction in the upper airways, but also during rehabilitation after ENT surgery, particularly in patients following radical laryngectomy due to cancer. Unfortunately, tracheostomy tubes used in the specific mucosal environment of the trachea and oesophagus show a limited lifespan of up to 6 months. This means that inserted tubes must be replaced regularly due to deterioration. Limitations in the function of the tubes over the course of their use are caused by various material factors that depend on the properties of the tubes or on the condition of the environment in the human body. The purpose of this paper is to evaluate the surface condition of tracheostomy tubes after 2 days and after 3 months of use.
Rurki tracheostomijne są powszechnie stosowane nie tylko w nagłych przypadkach zablokowania przepływu powietrza przez górny odcinek dróg oddechowych, ale także podczas rehabilitacji po zabiegach laryngologicznych, w szczególności u chorych po radykalnym usunięciu krtani w przebiegu choroby nowotworowej. Specyficzne środowisko śluzówek tchawicy i przełyku wpływa niestety na ograniczenie żywotności rurek tracheostomijnych maksymalnie do 6 miesięcy. Oznacza to, że założone rurki wymagają okresowej wymiany z powodu obniżenia ich jakości. Ograniczenia funkcjonowania rurek w miarę ich użytkowania są spowodowane różnymi czynnikami materiałowymi, zależnymi od właściwości rurek lub zależnymi od stanu środowiska w organizmie człowieka. Przedmiotem badań w prezentowanej pracy jest ocena stanu powierzchni rurek tracheostomijnych po użytkowaniu przez 2 dni i przez 3 miesiące.
Źródło:
Ochrona przed Korozją; 2023, 11; 348-353
0473-7733
2449-9501
Pojawia się w:
Ochrona przed Korozją
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of typical flow disturbing elements on the flow rate in selected averaging Pitot tubes
Autorzy:
Pochwała, S.
Kabaciński, M.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/1933974.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska
Tematy:
averaging pitot tubes
flowmeter
Opis:
Flowmeters with averaging Pitot tubes are becoming more and more common in the industrial practice. It is often the case in long straight sections of channels with large diameters that the conditions regarding the adequately long sections of pipelines before and behind a flowmeter cannot be fulfilled. This is associated with the occurrence of an additional measurement uncertainty with an unknown value. Most of the information regarding this issue can be found for the case of Venturi probes. The amount of data regarding the flow averaging Pitot tubes is also limited. Hence, the decision to undertake the proposed subject. The conducted research made it possible to state recommendations regarding the metrology of testing. The results indicate that it is not only the distance from the flow disturbing element that plays a role but it is also the plane in which the sensor is located that affects the uncertainty of measurements of the flow averaging Pitot tubes.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2012, 16, 3-4; 219-228
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental and Numerical Studies of the Behavior and Energy Absorption of Foam-Filled Circular Tubes
Autorzy:
Kaczyński, P.
Karliński, J.
Hawryluk, M.
Powiązania:
https://bibliotekanauki.pl/articles/351242.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
numerical simulation
single-walled tubes
double-walled tubes
polyurethane foam
energy absorption
dynamic axial crush
Opis:
Following paper is focused on experimental and numerical studies of the behavior and energy absorption for both: quasi-static and dynamic axial crushing of thin-walled cylindrical tubes filled with foam. The experiments were conducted on single walled and double walled tubes. Unfilled profiles were compared with tubes filled with various density polyurethane foam. All experiments were done in order to possibility of the safety of the elements absorbing collision energy which can applied in car body. The dynamic nonlinear simulations were carried out by means of PAM-CRASH™ explicit code, which is dedicated calculation package to modelling of crush. Computational crushing force, plastic hinges locations and specimens post-crushed geometry found tobe convergent with the real experiments results. Conducted experiments allowed to draw conclusion, that crashworthiness ability is directly proportional to foam density. The investigation of the experimental data revealed, that double walled tubes have greater energy absorbing ability. A proposed investigation enable to analyze and chosen of optimal parameters of these elements, which can use in automotive industry as an absorption energy components.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 2; 521-527
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Applicability of Flow Averaging Pitot Tubes in the Areas of Flow Disturbance
Autorzy:
Pochwała, S.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/221838.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
averaging Pitot tubes
flowmeter
measurement uncertainty
Opis:
The issues connected with the complex design of various facilities, including up-to-date boiler equipment as well as the ways of organizing the space around them, are the reasons why there is often a lack of room for mounting a flowmeter in accordance with the recommendations of manufacturers. In most cases the problem is associated with ensuring sufficient lengths of straight pipe leading into and out of a flowmeter. When this condition cannot be fulfilled, the uncertainty of measurement increases above the value guaranteed by the manufacturer of the flowmeter. This sort of operation problem has encouraged the authors of this paper to undertake research aimed at the analysis of applicability of averaging Pitot tubes in the areas of flow disturbance.
Źródło:
Metrology and Measurement Systems; 2016, 23, 1; 71-84
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of flowing fluid effect on flow averaging tube
Autorzy:
Kabaciński, M.
Lachowicz, C.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/1943247.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska
Tematy:
flow averaging tubes
numerical simulations
flow measurements
Opis:
This paper presents a mathematical model and results of numerical simulations for a fluid flow around a flow averaging tube. The calculations have been performed using the commercially available FLUENT software. The authors have applied the currently known studies of the models of turbulence and their applicability in certain flow conditions and hence selected the RNG k-epsylon turbulence model including appropriate functions to be used for determination of pressures and velocities at the sites of occurrence of considerable gradients. The distributions of pressures and velocities around a sensor are presented along with pressure distributions, instantaneous and averaged in time, on the measuring tube surface. The paper determines the frequencies of measuring tube free vibrations for one sided and two-sided tube fitting for the tube length in the range 100–1500mm. This analysis has been conducted with the aid of solving equations for free undamped vibrations for specific models. The graphical presentation involves an admissible range of tube lengths with one and two-sided fitting for the specified flowing air velocities.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2008, 12, 3-4; 217-226
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eulalia picta Kinberg, 1866 – tube builder or specialized predator?
Autorzy:
Pabis, Krzysztof
Sobczyk, Robert
Powiązania:
https://bibliotekanauki.pl/articles/2042149.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Admiralty Bay
Antarctic
Eteoninae
Phyllodocidae
sediments
Tubes
Źródło:
Polish Polar Research; 2017, 38, 4; 485-491
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis and optimization of outputs of high power microwave tubes
Autorzy:
Węgrzyniak, P.
Gwarek, W.
Baczewski, D.
Powiązania:
https://bibliotekanauki.pl/articles/307618.pdf
Data publikacji:
2007
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
high power microwave tubes
optimization of outputs
Opis:
The subject of this work is optimization of outputs of L-band high power microwave tubes. These outputs are constructed as coaxial-to-waveguide transitions with a vacuum barrier in a form of glass or ceramic cup. The goal of optimization is to obtain sufficiently low reflection loss in the predefined frequency band and to avoid so called hot spots caused by excessive dissipation of microwave power in parts of the cup. Electromagnetic simulator has been applied to model the behavior of the optimized transition and to propose its optimum shape. The proposed solutions were verified by Z.E. Lamina SA in prototypes of high power (pulsed 600 kW) amplitrons and are to be used in manufacturing practice.
Źródło:
Journal of Telecommunications and Information Technology; 2007, 1; 35-39
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the strength properties of materials intended for tracheobronchial tubes
Autorzy:
Sobota, Robert
Markowski, Jarosław
Joszko, Kamil
Gzik-Zroska, Bożena
Kawlewska, Edyta
Gzik, Marek
Powiązania:
https://bibliotekanauki.pl/articles/1844981.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
thermoplastic elastomer
tracheobronchial tubes
oxidative degradation
hydrolytic degradation
Opis:
The desire to increase the comfort of patients and to continue production despite the decreasing amount of available materials on the market has led to the constant search for novel materials that could be used to obtain tracheobronchial tubes. The aim of this study is to determine the mechanical properties of a new thermoplastic elastomer. Two materials - the thermoplastic elastomer and the natural rubber were subjected to three tests: static tensile test, static compression test and static three-point bending test. During the static tensile test, samples of the tested materials were examined, and during the next two examinations, the final products. The materials underwent the processes of sterilization, hydrolytic degradation and degradation by oxidation. The treated samples were also tested in order to compare the obtained results. The mechanical properties of the tested materials improved both after the hydrolytic degradation and oxidative degradation, as well as after the sterilization process. Yet the thermoplastic elastomer revealed a more noticeable increase. The elastomer hardening is a positive phenomenon potentially leading to fewer accidental closures of the tubes cross-section. Both the sterilization process and various degradation methods improved the mechanical properties by strengthening the tested materials. This phenomenon seems to be desirable to avoid the closure of the implemented tube during its application.
Źródło:
Engineering of Biomaterials; 2020, 23, 156; 10-16
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical analysis on Rib-tubes of seawater open rack vaporizer with the spoiler lever
Autorzy:
Su, H.
Yu, S.
Fan, J.
Xing, W.
Powiązania:
https://bibliotekanauki.pl/articles/258810.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
spoiler lever
Open Rack Vaporizer(ORV)
Rib-tubes
numerical simulation
Opis:
In order to explore a more reasonable structure and operating parameter, guide the design and improve the gasification of seawater Open Rack Vaporizer (ORV), Research on the rules of seawater that flows and heat transfer in the ORV tube was studied in this paper. By simplifying the model, heat transfer tube model with spoiler lever was obtained and simulated, the distribution of temperature field, gas ratio, velocity field and press field in rib tube were analyzed, and different inlet velocity of LNG, roughness of the tube wall both effected on the overall gasification, the results shows that the actual gasification efficiency from heat transfer tube is higher than normal, small difference of gas ratio outlet, velocity and temperature are both lower, LNG could be easer gasified at operating temperature between -162°C~+3°C than that between -162°C~+0°C.
Źródło:
Polish Maritime Research; 2017, S 2; 14-21
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena właściwości wytrzymałościowych materiałów na rurki tracheostomijne
Assessment of the strength properties of tracheostomy tubes
Autorzy:
Sobota, Robert
Joszko, Kamil
Gzik-Zroska, Bożena
Markowski, Jarosław
Kawlewska, Edyta
Powiązania:
https://bibliotekanauki.pl/articles/2201488.pdf
Data publikacji:
2019
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
rurki tracheostomijne
właściwości mechaniczne
biomateriały
tracheostomy tubes
mechanical properties
biomaterials
Opis:
W pracy przedstawiono wyniki badań wytrzymałościowych materiału wykorzystywanego do produkcji rurek tracheostomijnych oraz dwóch materiałów, przewidzianych do ich produkcji w nowej technologii wywarzania. Przebadano trzy materiały (polietylen małej gęstości przeznaczonego do wytłaczania - polietylen nr 2 oraz dwóch polietylenów małej gęstości przeznaczonych do przetwarzania za pomocą procesu wtrysku - polietylen nr 1 oraz polietylen nr 3) dla których wyznaczono maksymalną siłę zginającą i ściskającą oraz maksymalne naprężenia. Uzyskane wyniki badań poddano analizie w celu poszukiwania optymalnego materiału wykorzystywanego w procesie produkcyjnym.
The paper presents the results of strength tests of the material used for the production of tracheostomy tubes and two materials intended for their production in the new manufacturing technology. Three materials (low density polyethylene intended for extrusion - polyethylene No. 2 and two low density polyethylenes intended for injection molding - polyethylene No. 1 and polyethylene No. 3) were tested for which the maximum bending and compressive force and maximum stress were determined. The obtained test results were analyzed in order to search for the optimal material used in the production process.
Źródło:
Aktualne Problemy Biomechaniki; 2019, 18; 47--53
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Enzymatic profile, adhesive and invasive properties of Candida albicans under the influence of selected plant essential oils
Autorzy:
Budzyńska, Aleksandra
Sadowska, Beata
Więckowska-Szakiel, Marzena
Różalska, Barbara
Powiązania:
https://bibliotekanauki.pl/articles/1039346.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
adhesion
Candida albicans
hydrolytic enzymes
germ tubes
invasion
mycelium
Opis:
The influence of essential oils (EOs) used at sublethal level, on the presence and intensity of Candida albicans virulence factors was evaluated. Minimal inhibitory concentrations (MICs) of Lemon balm, Citronella, Geranium and Clove oils were established as 0.097% (v/v). Using the agar plates with substrates for proteases, phospholipases and hemolysins it was shown that C. albicans ATCC 10231 and C. albicans ATCC 90028 strains differed in the type and amount of enzymes produced. No significant difference in their total amount could be detected after pretreatment for 24 h with EOs at ½ MIC. However, the short-term (1 h) acting oils at MIC caused a statistically significant reduction in this activity. In the API ZYM test it was demonstrated that both strains exhibited activity of the same 9 out of 19 enzyme types and that EOs caused a significant decrease in the release of some of them. In the presence of subMIC of EOs, or when the fungus had previously been exposed to the MIC of oil, germ tubes formation was significantly and irreversibly reduced. Such C. albicans spotted on the Spider agar containing EOs at subMICs were unable to penetrate the agar. A significant decrease in the C. albicans adhesion to the fibroblast monolayer with respect to controls was also demonstrated when yeasts had been exposed to EOs at MIC (1 h) in liquid medium. Thus, it has been shown that tested oils, used even at subMIC, exhibit significant activity reducing the presence/quantity of important C. albicans virulence factors.
Źródło:
Acta Biochimica Polonica; 2014, 61, 1; 115-121
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Generalized model of strains during bending of metal tubes in bending machines
Autorzy:
Śloderbach, Z.
Powiązania:
https://bibliotekanauki.pl/articles/279709.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
tubes bending
deformations
bending angle
thickness of the wall
neutral axis
Opis:
According to the postulate concerning a local change of the “actual active radius” with a bending angle in the bent zone, a generalized model of strain during bending of ametal tube has been derived. The considered tubes should be subjected to bending in tube bending machines by the method of wrapping on a rotating template and with the use of a lubricated steel mandrel. The model is represented by three components of strain in the analytical form, including displacement of the neutral axis. Generalization of the model of metal tubes in the existing papers consists in including the displacement of the neutral axis and the possibility of determination of strains at each point along the thickness of the wall of the bent tube in the bending zone. The derived scheme of strain satisfies initial and boundary kinematic conditions of the bending process, conditions of continuity and inseparability of strains. The obtained analytical expressions can be classified as acceptable from the kinematic point of view.
Źródło:
Journal of Theoretical and Applied Mechanics; 2014, 52, 4; 1093-1106
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of High Temperature Corrosion Resistance of Finned Tubes Made of Austenitic Steel And Nickel Alloys
Autorzy:
Turowska, A.
Adamiec, J.
Powiązania:
https://bibliotekanauki.pl/articles/353941.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
finned tubes
laser welding
high temperature corrosion
austenitic steel
nickel alloys
Opis:
The purpose of the paper was to evaluate the resistance to high temperature corrosion of laser welded joints of finned tubes made of austenitic steel (304,304H) and nickel alloys (Inconel 600, Inconel 625). The scope of the paper covered the performance of corrosion resistance tests in the atmosphere of simulated exhaust gases of the following chemical composition: 0.2% HCl, 0.08% SO2, 9.0% O2 and N2 in the temperature of 800°C for 1000 hours. One found out that both tubes made of austenitic steel and those made of nickel alloy displayed good resistance to corrosion and could be applied in the energy industry.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2B; 1089-1093
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design of Acoustic Tubes Array and Application to Measuring Acoustic Loads in Supersonic Airflow
Autorzy:
Wei, L.
Li, M.
Fu, Q.
Fan, Y.
Yang, D.
Powiązania:
https://bibliotekanauki.pl/articles/176750.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic load
acoustic tubes array
near field measurement
supersonic airflow
Opis:
In the acoustic fatigue experiment for hypersonic vehicle in simulated harsh service environment on ground, acoustic loads on the surface of test pieces of the vehicle need to be measured. However, for the normal microphones without high temperature resistance ability, the near field sound measurement cannot be achieved. In this work, on the basis of previous researches, an acoustic tubes array is designed to achieve the near field measurement of acoustic loads on the surface of the test piece in the supersonic airflow with high temperature achieved by coherent jet oxygen lance. Firstly, the process of designing this acoustic tubes array is introduced. Secondly, the equality of phase differences at the front and at the end of the tubes is stated and proved using a phase differences test with an acoustic tubes array whose design is presented in this text; therefore, the phase differences of signals acquired by microphones can be directly applied to beamforming algorithm to determine the acoustic load source. Finally, using above mentioned acoustic tubes array, measurement of acoustic load, with and without a test piece in the supersonic airflow made by the coherent jet oxygen lance, is conducted respectively, and the measurements results are analyzed.
Źródło:
Archives of Acoustics; 2014, 39, 3; 395-402
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie depozycji cząstek aerozolowych w rurkach dozujących (Endotracheal tube) stosowanych podczas podawania leków
Deposition of aerosol particles in dosing tubes (endotracheal tubes) used in aerosol drug therapy of infants
Autorzy:
Żywczyk, Ł.
Moskal, A.
Sosnowski, T. R.
Powiązania:
https://bibliotekanauki.pl/articles/2071066.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
osadzanie cząstek
kanały tchawiczne
leki aerozolowe
particles deposition
endotracheal tubes
aerosol drugs
Źródło:
Inżynieria i Aparatura Chemiczna; 2010, 1; 125-126
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of phase transformation model for the simulation of controlled cooling of bainitic steel tubes
Identyfikacja modelu przemian fazowych dla potrzeb symulacji kontrolowanego chłodzenia rur ze stali bainitycznych
Autorzy:
Kuziak, R.
Radwański, K.
Molenda, R.
Mazur, A.
Broll, J.
Pietrzyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/181466.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Metalurgii Żelaza im. Stanisława Staszica
Tematy:
phase transformations
JMAK model
tubes of bainitic steels
numerical simulations of tubes cooling
przemiany fazowe
model JMAK
rury ze stali bainitycznych
modelowanie numeryczne chłodzenia rur
Opis:
JMAK (Johnson-Mehl-Avrami-Kolmogorov) equation was adapted to simulation of phase transformations during cooling of bainitic steel tubes. The model was identified on the basis of the results obtained from the JMatPro software. Numerical tests for various cooling schedules showed model’s capability to predict a volume fraction of microstructure constituents of the tubes. The model was implemented into FE code for the simulation of tubes cooling. For the sake of the model capabilities, three cooling methods were considered: (i) free cooling in the air, (ii) cooling with the pressurised air, (iii) cooling with the water mist. Both symmetrical and asymmetrical cooling conditions were considered. The volume fractions of the tube’s microstructure constituents were calculated for each cooling conditions.
W artykule adaptowano model JMAK (Johnson-Mehl-Avrami-Kolmogorov) do symulacji numerycznej przemian fazowych w procesie chłodzenia rur ze stali bainitycznych. Identyfikację modelu przemian fazowych przeprowadzono na podstawie wyników obliczeń wykonanych za pomocą programu komputerowego JMatPro. Badania numeryczne, przeprowadzone dla różnych metod chłodzenia rur, pokazały możliwości obliczeniowe opracowanego modelu, które obejmują przewidywania udziałów objętościowych składników mikrostruktury stali podczas chłodzenia po austenityzacji. Opracowany model numeryczny przemian fazowych implementowano w kodzie opartym na metodzie elementów skończonych (MES), symulującym proces chłodzenia rur. Obliczenia przeprowadzono dla następujących warunków chłodzenia: (i) chłodzenie w spokojnym powietrzu, (ii) chłodzenie sprężonym powietrzem, (iii) chłodzenie mgłą wodno-powietrzną. Dla każdego sposobu chłodzenia, obliczono udziały objętościowe składników mikrostruktury rur.
Źródło:
Prace Instytutu Metalurgii Żelaza; 2018, T. 70, nr 4, 4; 24-33
0137-9941
Pojawia się w:
Prace Instytutu Metalurgii Żelaza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite element analysis on the flexural behaviour of concrete filled steel tube beams
Metoda elementów skończonych w badaniu właściwości stalowych kolumn
Autorzy:
Arivalagan, S.
Kandasamy, S.
Powiązania:
https://bibliotekanauki.pl/articles/280039.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
finite element analysis
concrete filled steel tubes
normal mix concrete
quarry waste concrete
Opis:
Concrete-filled steel tube (CFST) beams are studied and verified by the Finite Element program ANSYS against experimental data. In the nu- merical analysis, the cross sections of the CFST are square steel sections, and sections strengthened by being filled with normal mix concrete and quarry waste concrete. Numerical analyses have shown that for square CFST a good confining effect can be provided. This effect is enhanced especially by the filling.
W pracy przedstawiono analizę porównawczą wyników eksperymentalnych i otrzymanych z metody elementów skończonych (ANSYS) w odniesieniu do kolumn zbudowanych ze stalowych rur wypełnionych betonem (CFTS). Analizę numeryczną przeprowadzono dla kolumn o przekroju kwadratowym wzmacnianym normalną mieszanką betonową oraz betonem zawierającymodpady z kamieniołomu. Rezultaty symulacji numerycznych pokazały, że dla kolumn CFTS o przekroju kwadratowym uzyskuje się dobry efekt wzmocnienia wynikający z wypełnienia.
Źródło:
Journal of Theoretical and Applied Mechanics; 2010, 48, 2; 505-516
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diminishment of internal polygonization of tubes in hot stretch-reducing mill
Zmniejszenie wewnętrznej poligonizacji rur w walcarce redukcyjnej na gorąco
Autorzy:
Stefański, K.
Kubiński, W.
Powiązania:
https://bibliotekanauki.pl/articles/263813.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
walcowanie redukcyjne
rury stalowe
poligonizacja wewnętrzna
stretch-reducing rolling
steel tubes
internal polygonization
Opis:
One of the most important issues in hot stretch-reducing process is the maintaining precision of wall thickness. Exactly the same wall thickness at all cross-sections of tubes after stretch-reducing mill increases suitability of tubes in the next treatment processes. Internal polygonization of tubes and its removal during hot reducing is constantly the most important problem. The study is a presentation of test results for decrease of internal polygonization. Internal polygonization, as a result of deformation of tube wall thickness in all stands during hot reducing, can be minimized first of all by optimization of inter-stand tension. The tubes and pipes with minimal internal polygonization could be obtained during experiments of rolling after applying maximal average tension using a developed system for equations of axial forces equilibrium in the rolling mill.
Jednym z najważniejszych zagadnień w procesie walcowania redukcyjnego rur na gorąco jest dotrzymanie dokładności grubości ścianki. Dokładnie taka sama grubość ścianki rury na całym jej przekroju po walcowaniu redukcyjnym zwiększa przydatność rur do następnych procesów obróbki. Usunięcie wewnętrznej poligonizacji rur podczas walcowania redukcyjnego na gorąco jest wciąż najważniejszym problemem. Opracowanie jest prezentacją wyników badania nad zmniejszeniem wewnętrznej poligonizacji. Wewnętrzna poligonizacja jako wynik odkształcenia grubości ścianki rury we wszystkich klatkach podczas redukowania na gorąco może być minimalizowana przede wszystkim przez optymalizację naciągu między klatkami. Korzystając z układów równań równowagi sił osiowych, możliwe było podczas eksperymentów uzyskanie rur z minimalną wewnętrzną poligonizacją po zastosowaniu maksymalnego średniego naciągu.
Źródło:
Metallurgy and Foundry Engineering; 2010, 36, 1; 21-29
1230-2325
2300-8377
Pojawia się w:
Metallurgy and Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes in Hydrogen Content During Steelmaking
Zmiany zawartości wodoru w kąpieli metalowej podczas procesu stalowniczego
Autorzy:
Vrbek, K.
Lamut, J.
Marolt, M.
Knap, M.
Powiązania:
https://bibliotekanauki.pl/articles/354364.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hydrogen content
pin tubes
tundish
deoxidation
zawartość wodoru
rurki próżniowe
kadź pośrednia
odtlenianie
Opis:
Štore Steel produces steel grades for spring, forging and engineering industry applications. Steelmaking technology consists of scrap melting in Electric Arc Furnace (EAF), secondary metallurgy in Ladle Furnace (LF) and continuous casting of billets (CC). Hydrogen content during steelmaking of various steel grades and steelmaking technologies was measured. Samples of steel melt from EAF, LF and CC were collected and investigated. Sampling from Electric Arc Furnace and Ladle Furnace was carried out using vacuum pin tubes. Regular measurements of hydrogen content in steel melt were made using Hydris device. Hydrogen content results measured in tundish by Hydris device were compared with results from pin tube samples. Based on the measurement results it was established that hydrogen content during steelmaking increases. The highest values were determined in tundish during casting. Factors that influence the hydrogen content in liquid steel the most were steelmaking technology and alloying elements.
Stalownia Štore Steel produkuje gatunki stali sprężynowych, stali do kucia oraz stali do innych zastosowań przemysłowych. Linia technologiczna obejmuje elektryczny piec łukowy (EAF), rafinację pozapiecową w piecu kadziowym (LF) oraz maszynę do ciągłego odlewania kęsów (COS). Badaniom poddana została zmienność zawartości wodoru w stali w zależności od gatunku stali i wybranej linii technologicznej. Zgromadzono bazę danych w postaci próbek pobieranych z pieca łukowego, pieca kadziowego oraz maszyny COS. Próbki z pieca łukowego oraz pieca kadziowego pobierano za pomocą rurek próżniowych. Przeprowadzano regularnie pomiary zawartości wodoru w stali za pomocą urządzenia Hydris. Mierzoną zawartość wodoru w kadzi pośredniej za pomocą urządzenia Hydris porównywano z zawartością wodoru w próbkach pobranych za pomocą rurek próżniowych. Bazując na opisanych pomiarach stwierdzono wzrost zawartości wodoru w stali w czasie realizowanego procesu stalowniczego. Najwyższe zawartości stwierdzono w kadzi pośredniej urządzenia COS. Czynnikami mającymi największy wpływ na zawartość wodoru w ciekłej stali była zastosowana technologia wytapiania oraz pierwiastki stopowe.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 1; 295-299
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Microaspiration Around Taperguard Tube Cuffs and Standard Tracheal Tubes in Obese Patients Subjected to Surgery Under General Anesthesia
Autorzy:
Gaszyńska, Ewelina
Ratajczyk, Paweł
Wieczorek, Andrzej
Szewczyk, Tomasz
Gaszyński, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1395728.pdf
Data publikacji:
2014-03-01
Wydawca:
Index Copernicus International
Tematy:
endotracheal intubation
general anesthesia
tracheal tubes
cuff tightness
microaspirations
ventilator-associated pneumonia
Opis:
Tracheal secretion leakage might lead to ventilator-associated pneumonia. Standard tracheal tube cuffs are cylindrical in shape. Bronchial tree aspiration is observed in the presence of leakage past tracheal tube cuffs. The new TaperGuard tracheal tube has a cuff in the shape of a cone, preventing from the development of microtubules and microaspiration. The aim of the study was to compare standard tracheal tube cuffs with TaperGuard tubes, in terms of protection from microaspiration under general anesthesia. Material and methods. The observational study evaluated incidents of leakage during general anesthesia with intubation and mechanical ventilation in patients with significant obesity. The study group comprised 20 patients with the BMI >40 kg/m2 subjected to elective surgery under general anesthesia with intubation and mechanical ventilation, randomly divided into two subgroups: standard tracheal tube and TaperGuard tube. Results. In 4 of 10 patients with standard tracheal tubes we observed leakage around the cuff. In case of TaperGuard tubes no such leakage was observed. Conclusion. TaperGuard tubes protect against microaspirations, while standard tracheal tubes have no such properties.
Źródło:
Polish Journal of Surgery; 2014, 86, 3; 107-110
0032-373X
2299-2847
Pojawia się w:
Polish Journal of Surgery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A derivation of the generalized model of strains during bending of metal tubes at bending machines
Autorzy:
Śloderbach, Z.
Powiązania:
https://bibliotekanauki.pl/articles/955183.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
zginanie
rura metalowa
giętarka
bending
metal tubes
bending machine
strains
neutral axis
Opis:
According to the postulate concerning a local change of the “actual active radius” with a bending angle in the bend zone, a generalized model of strain during metal tube bending was derived. The tubes should be subjected to bending at tube bending machines by the method of wrapping at the rotating template and with the use of a lubricated steel mandrel. The model is represented by three components of strain in the analytic form, including displacement of the neutral axis. Generalization of the model during bending metal tubes at the tube bending machines as compared with the existing papers (Śloderbach, 1999; Śloderbach and Rechul, 2000) consists in including the neutral axis displacement and possibility of determination of strains at each point along the thickness of the wall of the bent tube in the bending and bend zone. The derived scheme of strain satisfies initial and boundary kinematic conditions of the bending process, conditions of continuity and inseparability of strains. The obtained analytic expressions can be classified as acceptable from the kinematic point of view.
Źródło:
International Journal of Applied Mechanics and Engineering; 2014, 19, 1; 145-163
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Comparative Study on Ballistic Behaviour of MWCNT / Graphene Reinforced AL6061 Surface Composites Fabricated Via Friction Stir Processing
Autorzy:
Magarajan, U.
Suresh Kumar, S.
Powiązania:
https://bibliotekanauki.pl/articles/27324483.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
ballistic behaviour
friction stir processing
graphene
Multi Walled Carbon Nano Tubes
depth of penetration
Opis:
In this work, a comparative study on the ballistic behaviour of friction stir processed AL6061 targets had been made. Base Metal AL6061 (BM) plates with 25 mm thickness were friction stir processed by adding Multi Walled Carbon Nano Tubes (MWCNT) and Graphene (G), producing AL6061-MWCNT and AL6061-G surface composites. Optical microscopy and microhardness test on BM, AL6061-MWCNT and AL6061-G samples were performed as per the standard procedure. It was noticed that uniform dispersion of ceramic particles and refined grains were obtained for the friction stir processed surface composites. From the microhardness test, it was perceived that friction stir processing had induced strengthening of surface composites, hence increasing the microhardness of AL6061-MWCNT and AL6061-G by ~60.3% and ~73.6% respectively. Also, ballistic experiments were conducted at 680±10 m/s by impacting Ø7.62×51 mm projectiles. AL6063 backing plates were placed to compare the ballistic behaviours AL6061-MWCNT and AL6061-G targets by depth of penetration. It was noted that the depth of penetration of AL6061-MWCNT and AL6061-G targets were 37.81% and 65.84% lesser than the BM target. Further, from the results of Post ballistic microscopy it was observed that the microstructure near and away from the penetration channel edge looks unchanged in BM target. However, the AL6061-MWCNT and AL6061-G targets showed considerable change in their morphology, by forming Adiabatic Shear Bands.
Źródło:
Archives of Metallurgy and Materials; 2023, 68, 2; 541--550
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Numerical and Experimental Analysis of Ballizing Process of Steel Tubes
Autorzy:
Dyl, T.
Powiązania:
https://bibliotekanauki.pl/articles/356697.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
numerical analysis
strain and stress state
burnishing (surface plastic forming)
ballizing process
steel tubes
Opis:
This paper presents chosen results of experimental and numerical research of ballizing process of the steel tubes. Ballizing process is a method of burnishing technology of an internal diameter by precisely forcing a ball through a slightly undersized premachined tubes. Ballizing process is a fast, low-cost process for sizing and finishing tubes. It consists of pressing a slightly oversized ball through an unfinished tube to quickly bring the hole to desired size. The ball is typically made from a very hard material such as tungsten carbide or bearing steel. Ballizing process is by cold surface plastic forming of the surface structure, thereby leaving a layer of harder material and reducing its roughness. After theoretical and experimental analysis it was determined that the smaller the diameter of the balls, the bigger intensity of stress and strain and strain rate. The paper presents influence of ballizing process on the strain and stress state and on the surface roughness reduction rate of the steel tubes.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2A; 807-814
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies