Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "PM2,5" wg kryterium: Temat


Tytuł:
Air pollution: how many cigarettes does each Pole ‘smoke’ every year and how does it influence health, with special respect to lung cancer?
Autorzy:
Chudzik, R.
Rybojad, P.
Jarosz-Chudzik, K.
Sawicki, M.
Rybojad, B.
Panasiuk, L.
Powiązania:
https://bibliotekanauki.pl/articles/2085106.pdf
Data publikacji:
2019
Wydawca:
Instytut Medycyny Wsi
Tematy:
lung cancer
PM2.5
air pollution
nitrogen dioxide
PM10
Opis:
Introduction. Air pollution is one of the most important issues of our times. Air quality assessment is based on the measurement of the concentration of substances formed during the combustion process and micro-particles suspended in the air in the form of an aerosol. Microscopic atmospheric particulate matters (PM) 2.5 and 10 are mixtures of organic and inorganic pollutants smaller than 2.5 and 10 μm, respectively. They are the main cause of negative phenomena in the earth’s atmosphere of Earth and human health, especially on the respiratory and cardiovascular systems. Particulates have the ability to cause permanent mutations of tissue, leading to neoplasms and even premature deaths. Nitrogen dioxide (NO2) is one of the main pollutants which arises mainly during the burning of fossil fuels. Based on numerous scientific researches, it has been proved that long-term exposure to NO2 could increase morbidity of cancer due to inflammatory processes increasing abnormal mutations. Materials and method. Data available in the Polish National Cancer Registry, Chief Inspectorate for Environmental Protection and Map of Health Needs in the Field of Oncology for Poland, WHO Air Quality Guidelines 2005 were analyzed. Air pollution was also evaluated: PM2.5, PM10, NO2, and compared with lung cancer morbidity. Results and conclusions. Based on the available data and literature, it can be concluded that in 2009–2017, on average, each Pole smoked ten cigarettes a day +/- 2. Therefore, it can be estimated that after 60 years everyone had 30 package-years of smoking, leading to a high risk of lung cancer and other smoking related diseases. Additionally air quality in Poland is not satisfactory, exceeding the standards presented in the WHO Guidelines 2005. It can be assumed that this may translate into an additional, independent continuous increase in morbidity and mortality dependent on smoking.
Źródło:
Annals of Agricultural and Environmental Medicine; 2019, 26, 4; 566-571
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air purifier – individual protection against indoor particulate matter
Oczyszczacz powietrza – indywidualna ochrona przed pyłem powietrza wewnętrznego
Autorzy:
Chyc, Marek
Powiązania:
https://bibliotekanauki.pl/articles/1032109.pdf
Data publikacji:
2020
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
pollutants
treatment
allergens
pm10
pm2.5
zanieczyszczenia
uzdatnianie
alergeny
Opis:
The research work presents the findings of testing air purified using two commercial air purifiers available on the local market. Tests were carried out in the office and bedroom of a residential building. The results obtained show a high (75-93%) yield of air purification from particulate matter. Particulate matters fractions such as: PM1, PM2.5, PM4.0, PM10 and total suspended particulates (TSP) were analysed by means professional dust meter. A very strong correlation of particulate matter (PM) contents were found in individual particle classes during equipment operation. Obtained results approve high efficiency of equipment operation in the total range of measured values. This study is one of the first in the topic of assessing the effectiveness of PM purification, taking into account various dust fractions. This study should be useful for individual customers and for public utilities during purchase decisions.
W artykule zaprezentowano wyniki badań powietrza poddanego oczyszczaniu za pomocą dwóch urządzeń komercyjnych dostępnych na polskim rynku. Badania przeprowadzono w pomieszczeniu biurowym i sypialni domu mieszkalnego. Otrzymane wyniki wskazują na wysoki (75-93%) stopień oczyszczenia powietrza. Analizom poddano takie frakcje pyłowe jak: PM1, PM2,5, PM4,0, PM10 i pył całkowity (TSP). Stwierdzono bardzo silną korelację zawartości pyłów w poszczególnych klasach ziarnowych pyłów podczas pracy urządzeń. Oznacza to wysoką skuteczność pracy urządzeń w całym zakresie mierzonych zawartości zanieczyszczeń pyłowych. Opracowanie to jest jednym z pierwszych w zakresie oceny skuteczności oczyszczania pyłów z uwzględnieniem różnych frakcji pyłowych i może stanowić materiał pomocniczy dla użytkowników indywidualnych oraz decydentów rozważających zakup urządzeń oczyszczających powietrze dla jednostek oświatowych.
Źródło:
Health Promotion & Physical Activity; 2020, 10, 1; 13-19
2544-9117
Pojawia się w:
Health Promotion & Physical Activity
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An assessment of PM1 levels based on indicative PM1 measurements and relationships with PM10 and PM2.5 concentrations, for the analysis of hospital admissions and mortality in the Moravian region
Autorzy:
Šlachtová, Hana
Tomášek, Ivan
Polaufová, Pavla
Hellebrandová, Lucie
Šplíchalová, Anna
Tomášková, Hana
Powiązania:
https://bibliotekanauki.pl/articles/2081904.pdf
Data publikacji:
2021-06-30
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
PM 1 concentrations
spatiotemporal PM variations
heating season differences
air pollution
PM 2.5 concentrations
PM 10 concentrations
Opis:
Particulate matter (PM) air pollution is a serious concern in the city of Ostrava. Thus, in 2018, a project entitled “Validation of the relationships between PM10, PM2.5 and PM1 concentrations, and morbidity and mortality, in the heavily polluted region in the Czech Republic,” was launched. The relationship between hospital admissions and mortality in the said region is based primarily on short-term PM10 and PM2.5 concentrations and indicative PM1 measurement. The analysis of spatiotemporal variations and the relationship between PM10, PM2.5 and PM1 data from 3 measurement sites within the city of Ostrava is presented.Material and MethodsThe analysis was based on the daily average PM concentrations for 5 and 6 months at 2 sites, and on the annual average values (2018–2019) at the baseline station. The correlations of and variability between PM fractions, seasonal differences and explanation of the differences found were the objectives of a detailed analysis. Especially, the potential PM1 variability and its causes were analyzed with respect to the location of the site.ResultsThe study findings confirmed good correlations between the PM fractions. Compared to PM10, PM2.5 concentrations were more predictive for PM1 concentrations. The annual means of PM10, PM2.5 and PM1 reached 37.5, 29.9 and 27.1 μg/m3 in 2018, respectively, and 25.8, 19.9 and 17.9 μg/m3 in 2019, respectively. The concentration levels in the non-heating season were significantly lower than in the heating season in the 2 years under consideration. The levels of PM10, PM2.5 and PM1 were significantly correlated (the correlation coefficient, r > 0.96). The levels of PM2.5 represented about 0.82–0.86 of PM10, and the levels of PM1 about 0.92–0.93 of PM2.5. These ratios were found to differ in the heating and non-heating seasons, with the PM2.5–PM10 ratio ranging 0.61–0.63 in the non-heating seasons.ConclusionsThe correlations found will be used for indicative PM1 measurements in other areas of the region. Seasonal variability should be taken into account as well. Med Pr. 2021;72(3):249–58
Źródło:
Medycyna Pracy; 2021, 72, 3; 249-258
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza możliwości monitorowania stężeń pyłu respirabilnego przy pomocy czujników optycznych
ANALYSIS OF THE POSSIBILITY OF MONITORING OF THE CONCENTRATION LEVEL OF RESPIRABLE PARTICLES USING OPTICAL SENSORS
Autorzy:
Pastuszka, Józef S.
Cembrzyńska, Jolanta
Orłowski, Cezary
Mucha, Walter
Powiązania:
https://bibliotekanauki.pl/chapters/17841112.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
pył respirabilny
PM2.5
mierniki optyczne
czujniki pyłu
stężenie masowe
monitoring
Opis:
W pracy przeanalizowano zasadność wykorzystania tanich czujników pyłu do monitorowania narażenia na pył respirabilny PM2.5. W oparciu o przegląd danych literaturowych wykazano, że rosnące wymagania odnośnie prognoz niekorzystnych skutków zdrowotnych narażenia populacji generalnej na aerozol, zarówno w środowisku zewnętrznym, jak i wewnętrznym, wymagają znacznego zagęszczenia punktów pomiarowych, czego nie można osiągnąć poprzez istotne zwiększenie liczby stacji monitoringowych. Jedynym rozwiązaniem pozostaje zbudowanie gęstej sieci tanich czujników pyłu. W dalszej części pracy przedstawiono wstępne wyniki badań stężeń masowych pyłu PM2.5 w środowisku wewnętrznym, otrzymanych przy pomocy taniego sensora pyłu, oraz miernika optycznego Grimm, porównanych z wartościami stężeń otrzymanych metodą grawimetryczną przy użyciu samplera cząstek PM2.5, firmy SKC. Wyniki pomiarów stężeń PM2.5 otrzymanych przy pomocy czujnika pyłu różniły się od wyników pomiarów otrzymanych metodą grawimetryczną, o około 100% (odchylenie względne), podczas gdy tak wyznaczone odchylenie stężeń otrzymanych miernikiem Grimm`a wynosiło około 40%. Otrzymane wyniki wskazują, że aktualnie sensory pyłu mogą być wykorzystane jedynie do wstępnej analizy zapylenia powietrza, ale jak się wydaje mogą być z powodzeniem stosowane do pomiarów/badań dynamiki zmian stężeń pyłu w czasie prawie (quasi) rzeczywistym. Zwiększenie dokładności wyznaczania stężeń pyłu PM2.5 wymaga poprawy procedury kalibracji czujników a w dalszej kolejności opracowania technologii pomiarów stężeń pyłu przy pomocy zaawansowanych metod opracowywania danych pomiarowych, korygowanych w oparciu o specyficzną charakterystykę fizykochemiczną cząstek aerozolu w konkretnym receptorze (Internet Rzeczy).
It was indicated that for many reasons it is very important to build a dense network of cheap dust sensors. The paper presents preliminary results of the measurements of PM2.5 mass concentrations in the indoor environment, obtained with the use of a cheap dust sensor, and the Grimm optical device, compared with the values obtained using the gravimetric method. These research indicate that the results of measurements of PM2.5 concentrations obtained with the use of a dust sensor differed from the results obtained by gravimetric method, by about 100% (relative deviation), while the so-determined deviation of concentrations obtained with the Grimm particle counter was about 40%. Therefore, it can be concluded that currently dust sensors can be used only for preliminary analysis of the concentration of airborne particles, but it seems that they can be successfully used for measurements / studies of dynamics of changes in PM2.5 concentrations in almost (quasi) real time. Increasing the accuracy of determination of PM2.5 concentrations requires improvement of the sensor calibration procedure and further the development of technology for measuring PM2.5 concentrations by means of advanced methods of measuring data analysis, corrected on the basis of the specific physicochemical characteristics of aerosol particles in a specific sampling point.
Źródło:
Aktualne problemy w inżynierii i ochronie atmosfery; 174-181
9788374930208
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza stanu zanieczyszczenia powietrza atmosferycznego pyłem zawieszonym w miejscowości Supraśl
Autorzy:
Bolińska, Marta Iwona
Siemieniuk, Anna
Powiązania:
https://bibliotekanauki.pl/chapters/31232849.pdf
Data publikacji:
2023
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
zanieczyszczenie powietrza
pyły PM2.5
pyły PM10
Opis:
Działania antropogeniczne powodują zmiany klimatu, a co za tym idzie anomalie pogodowe. Zdarzały się one w ubiegłych wiekach, lecz naruszanie środowiska, zanieczyszczanie atmosfery i niszczenie naturalnych systemów ochronnych planety, takich jak warstwa ozonowa, powodują ich znaczne nasilenie i zwiększenie częstotliwości. Powodzie, susze, topnienie lodowców, podwyższenie średniej temperatury powierzchni Ziemi – na to wszystko człowiek miał i ma znaczący wpływ. Niniejsza praca przedstawia analizę zanieczyszczeń pyłowych powietrza w miejscowości Supraśl. W celu określenia skali tego zjawiska przeprowadzono badania jakości powietrza według określonej metodyki pomiarowej. Po zestawieniu wyników poszczególnych parametrów dokonano ich analizy, przeprowadzono dyskusję i wyciągnięto odpowiednie wnioski.
Źródło:
Innovations – Sustainability – Modernity – Openness. Środowisko; 24-35
9788367185615
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
ANALIZA WYBRANYCH ZANIECZYSZCZEŃ POWIETRZA W 2018 R. NA TERENIE BIELSKA-BIAŁEJ
Analysis of selected air pollutants in 2018 in Bielsko-Biała
Autorzy:
GÓRA, DARIUSZ
Powiązania:
https://bibliotekanauki.pl/articles/896379.pdf
Data publikacji:
2019
Wydawca:
Poznańskie Towarzystwo Przyjaciół Nauk
Tematy:
polycyclic aromatic hydrocarbons (PAH)
particulate matter (PM10 and PM2.5)
benzo(a)pyrene
Opis:
Chemical composition of polluted atmospheric air has a negative impact on human health as well as animals, water and soil. In effect it causes respiratory system disease, blood system disease and cancers. Children and elderly people are among the most endangered as their immune system is weak. It is estimated that every year in Poland 45000 people die as a result of polluted air. On a global scale the number rises to 7 million people. The aim of this elaboration is to present the concentration of chemical elements and particles, such as: suspended dust PM10 and PM2.5, nitro dioxide sulphur and benzo(a)pyrene, and to prove their negative impact on the human body. The article includes data from the Provincial Inspectorate for Environmental Protection in Katowice, Delegature in Bielsko-Biała. The next stage was to prepare appropriate graphs that show the concentrations of elements and chemical compounds in the air in individual months in 2018. The conducted analysis showed that the average annual PM2.5 dust concentration was 36 μg/m3, PM10 suspended dust 37 μg/m3, benzo(a)pyrene 4.47 ng/m3 and nitrogen oxides 62 μg/m3. In order to improve the sanitary state of the atmospheric air in the city of Bielsko-Biała and other areas with a high degree of urbanization, first of all reduce the sources of low emissions, i.e. emission of harmful dusts and gases from low emitters, which include chimneys, e.g from single-family houses or townhouses. Literature data show that exposure of people to particulate matter, benzo (a) pyrene and nitric oxides is mainly associated with an increased risk of heartbeat, bronchopulmonary and lung cancer and asthma.
Źródło:
Badania Fizjograficzne Seria A - Geografia Fizyczna; 2019, 10(70); 21-37
2081-6014
Pojawia się w:
Badania Fizjograficzne Seria A - Geografia Fizyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wyników pierwszej w Polsce kampanii pomiarowej składu pyłu zawieszonego w wysokiej rozdzielczości czasowej (pobornik Streaker)
ANALYSIS OF THE RESULTS OF THE FIRST MEASUREMENT CAMPAIGN OF PM ELEMENTAL COMPOSITION IN HIGH TIME RESOLUTION IN POLAND (STREAKER SAMPLER)
Autorzy:
Reizer, Magdalena
Maciejewska, Katarzyna
Juda-Rezler, Katarzyna
Powiązania:
https://bibliotekanauki.pl/chapters/16729248.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
pył zawieszony
PM2.5
PMc
pierwiastki śladowe
stężenia 1-godzinne
pobornik Streaker
analiza PIXE
identyfikacja źródeł
PMF
Warszawa
Opis:
Celem pracy jest identyfikacja źródeł pyłu zawieszonego (PM) oraz analiza dobowego profilu składników pyłu, z wykorzystaniem danych o wysokiej 1-godzinnej rozdzielczości czasowej uzyskanych w ramach, przeprowadzonej po raz pierwszy w Polsce i w Europie Środkowo-Wschodniej, kampanii pomiarowej w punkcie tła miejskiego w Warszawie. Próbki PM2,5 i PMc zostały zebrane za pomocą dwustopniowego pobornika Streaker (PIXE International Corporation). Analiza filtrów z wykorzystaniem techniki analizy emisji promieniowania X wzbudzonego przez cząstki – protony PIXE (ang. Particle Induced X-ray Emission) pozwoliła na uzyskanie stężeń masowych 27 pierwiastków w 1-godzinnej rozdzielczości czasowej. Kampania pomiarowa została przeprowadzona w okresie od 18 lutego do 10 marca 2016 r. Identyfikacja źródeł dla obu frakcji PM przeprowadzona za pomocą modelu EPA PMF umożliwiła określenie 7 źródeł PM2,5 oraz 5 źródeł PMc. Transport drogowy był głównym źródłem PMc (82% udziału), natomiast wtórny aerozol siarczanowy miał największy udział we frakcji drobnej (44%). Dobowe profile pierwiastków związanych z głównymi źródłami PM w Warszawie charakteryzowały się bimodalnym przebiegiem o maksymalnych stężeniach w godzinach porannych i popołudniowych.
The aim of present work is identification of particulate matter (PM) sources and analysis of daily profile of PM components using data with high 1-hour time resolution at urban background site in Warsaw, for the first time in Poland. Fine (PM2,5) and coarse (PMc) fractions of PM have been collected by a two-stage Streaker sampler (PIXE International Corporation). The filters have been analysed by Particle Induced X-ray Emission (PIXE) technique to obtain mass concentrations of 27 elements with hourly resolution. The measurement campaign were performed from 18th February to 10th March 2016. Source apportionment of fine and coarse PM fractions estimated by EPA PMF model allowed for the identification of 7 and 5 sources of PM2,5 and PMc, respectively. Traffic was found as the major source (82% share) in the coarse fraction, while fuel combustion in residential sector have the biggest share (44%) in the fine fraction. Daily profiles of elements in major PM sources showed the bimodal patterns with peak concentrations during morning and afternoon hours.
Źródło:
Aktualne problemy w inżynierii i ochronie atmosfery; 190-197
9788374930208
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wyników pomiarów stężeń zanieczyszczenia powietrza pyłem PM10 i PM2.5 na stacji pomiarowej plac Poznański w Bydgoszczy
Analysis of the results of measurement of concentrations of air pollution with PM10 and PM2.5 measuring station square of Poznan in Bydgoszcz
Autorzy:
Pasela, R.
Milik, J.
Budzińska, K.
Szejniuk, B.
Powiązania:
https://bibliotekanauki.pl/articles/399519.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
PM10
PM2.5
zanieczyszczenie powietrza
emisja zanieczyszczeń
emisja zanieczyszczeń monitoring
aglomeracja miejska
Bydgoszcz
air pollution
emission
monitoring
city agglomeration
Opis:
Zjawisko zanieczyszczenia pyłem zawieszonym PM10 i PM2,5 występuje w dużych aglomeracjach miejskich, gdzie głównym źródłem ich obecności jest komunikacja, co wiąże się przede wszystkim ze spalaniem paliw płynnych. Celem badań była ocena stanu zanieczyszczenia powietrza pyłem PM2,5 i PM10 dla wybranego obszaru miasta Bydgoszcz. Analizę przeprowadzono, wykorzystując dane pochodzące ze stacji monitoringu powietrza zlokalizowanej przy ul. Poznańskiej. Stacja jest własnością Wojewódzkiego Inspektoratu Ochrony Środowiska (WIOŚ) w Bydgoszczy. Badania wykazały, że najwyższe średnie dobowe stężenie pyłu wystąpiło w piątki i wynosiło odpowiednio 27,6 μg/m3 dla PM2,5 i 44,46 μg/m3 dla PM10. Zaobserwowano tendencję występowania wyższych wartości stężeń w sezonie grzewczym. Stwierdzono, iż średnie roczne stężenie pyłu zawieszonego (PM2,5 i PM10) w aglomeracji bydgoskiej jest bliskie przekroczenia poziomu dopuszczalnego ze względu na ochronę zdrowia ludzi.
The phenomenon of suspended particulate pollution PM10 and PM2.5 occurs in large urban areas where the main source of their presence is communication, which is primarily related to the combustion of liquid fuels. PM2.5 dust pollution is a major risk factor for diseases of the respiratory, cardiovascular, and allergy. Act regulating the standards and target dates for reducing concentrations of particulate matter in urban areas and in all the cities of over 100 thousand. residents of the Directive of the European Parliament and Council Directive 2008/50/EC of 21 May 2008. on ambient air quality and cleaner air for Europe (CAFE). The acceptable level of average daily concentration of PM10 is 50 μg/m3 and may be exceeded by not more than 35 times a year, while the level of allowable annual average concentration of 40 μg/m3. The aim of this study was to assess the state of air pollution of dust PM10 and PM2.5 for the selected area of the city of Bydgoszcz. The analysis was conducted using data from air monitoring stations located at Poznanska street. The station is owned by the Provincial Inspectorate for Environmental Protection (VIEP) in Bydgoszcz. The studies have shown that the annual average concentration of particulate matter analyzed station in Bydgoszcz in the years 2013–2015 amounted to PM10 41 μg/m3 PM2.5 and 23 μg/m3. The results are on the borderline of acceptable levels of concentration resulting from the Regulation of the Minister of the Environment of 2 August 2012. The concentrations of particulate matter in ambient air are strongly associated with meteorological conditions. The definitely higher concentrations observed in the autumn-winter season. The decrease in temperature causes the combustion in the boiler house of fuels with a high emissions. The highest average daily concentration of suspended particulate matter was observed on Thursday and Friday in the winter months, and while the lowest concentration was recorded in the summer months.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 1; 240-246
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza występowania pierwiastków śladowych w formie mobilnej frakcji respirabilnej pyłu (PM2,5) pobranego w otoczeniu elektrowni węglowej
Analysis of trace elements in the mobile form of respirable fraction PM2.5 collected in the surroundings of power plant
Autorzy:
Zajusz-Zubek, E.
Mainka, A.
Powiązania:
https://bibliotekanauki.pl/articles/297310.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
analiza specjacyjna
PM2,5
metale ciężkie
elektrownia węglowa
zanieczyszczenia powietrza
speciation analysis
heavy metals
power plant
air pollutants
Opis:
W pracy przedstawiono wstępne wyniki badań występowania wybranych pierwiastków śladowych (As, Cd, Co, Cr, Pb, Sb i Se), należących do grupy HAPs (ang. Hazardous Air Pollutants), w formie biodostępnej frakcji respirabilnej (PM2,5). Odpowiednią frakcję pyłu pobrano w otoczeniu pracującej elektrowni węglowej opalanej węglem kamiennym. Analiza specjacyjna frakcji pyłu PM2,5 została przeprowadzona według zmodyfikowanego schematu Tessiera z wykorzystaniem ekstrakcji formy rozpuszczalnej w wodzie (Frakcja 1). Średnie stężenia pierwiastków badanych we frakcji rozpuszczalnej w wodzie utworzyły następujący szereg: Pb>Cr>As>Sb>Cd>Se>Co. Jest on zbliżony do szeregu otrzymanego w źródłach literaturowych.
Research regarding environment and dust exposition conducted so far has been based on theoretical factors. These factors primarily concern the total content of heavy metals in suspended dust. However, there is a shortage of data on the specific chemical forms of trace elements. These forms condition the heavy metal threat on the environment and human health. Based on the results of chemical speciation, we can define the mobility of elements (including heavy metals) in the environment, that is, their bio-chemical activity during assimilation by organisms. The paper presents preliminary results of the occurrence of selected trace elements (As, Cd, Co, Cr, Pb, Sb and Se) that belong to the HAPs group (Hazardous Air Pollutants) in the PM2.5 water soluble form. The appropriate fraction of particulate matter was collected by Dekati PM10 Impactor in the surroundings of a working power plant that is fired with hard coal. The speciation analysis of PM2.5 fraction was conducted using a modified Tessier scheme. This procedure employs the extraction of a water soluble fraction (Fraction 1). The concentrations of elements were determined using the ICPMS technique. Measurements delivered data on the average concentration of respirable fraction PM2.5, which equaled 22.93 μg/m3. While conducting the research in the surroundings of a working power plant, a relatively high ratio of PM2.5 to TSP (83%) and to PM10 (88%) was found. Among the determined trace elements, the highest average total concentration in PM2.5 was found for Pb (82.17 ng/m3), while the lowest (less than 1 ng/m3) was found for Co. The highest average concentration in water soluble fraction F1 in PM2.5 was also found for Pb (12,97 ng/m3), while the lowest concentration (below 1 ng/m3) was found for Sb, Cd, Se and Co. The average concentrations of trace elements determined in the bioavailable fraction were found in a following order: Pb>Cr>As>Sb>Cd>Se>Co. This sequence is similar to the order received in the existing literature. In future, received data will assist in determining the forms of hazardous trace elements in total suspended particles (TSP), suspended dust (PM10) and in respirable fraction (PM2.5) in the surroundings of selected working power plants.
Źródło:
Inżynieria i Ochrona Środowiska; 2015, 18, 2; 245-258
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zmienności stężeń aerozolu węglowego na obszarze południowej Polski
VARIABILITY OF CARBON AEROSOL CONCENTRATIONS IN THE SOUTHERN AREA OF POLAND
Autorzy:
Zioła, Natalia
Klejnowski, Krzysztof
Błaszczak, Barbara
Mathews, Barbara
Błaszczak, Monika
Powiązania:
https://bibliotekanauki.pl/chapters/17820780.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
zanieczyszczenia powietrza
PM2.5
sadza
węgiel elementarny
węgiel organiczny
Opis:
Celem niniejszej pracy była analiza sezonowej zmienności stężeń aerozolu węglowego w powietrzu. Próbki pyłu PM2,5 pobierano od lutego 2015 do grudnia 2016 na terenie gminy Racibórz. Badania nad ilościowym i jakościowym składem aerozolu węglowego (OC, EC, TC) przeprowadzono przy użyciu metody termo-optycznej, z kolei stężenia sadzy EBC określono przy zastosowaniu metody optycznej. Otrzymane wyniki pozwoliły na stwierdzenia znacznych różnic stężeń materii węglowej w aerozolach w zależności od pory roku. Sezonowa zmienność stężeń aerozolu węglowego jest determinowana zwiększonym udziałem emisji zanieczyszczeń ze spalania paliw kopalnych w sezonie grzewczym oraz warunkami meteorologicznymi. Analizom poddano również wpływ typów cyrkulacji atmosfery na stężenia aerozolu węglowego. Uzyskane dane wskazują na istotny udział zanieczyszczeń z lokalnych źródeł emisji oraz transportu samochodowego w kształtowaniu jakości powietrza.
The aim of this study was to analyze the seasonal variability of carbon aerosol concentrations in the ambient air. PM2.5 samples were collected from February 2015 to December 2016 in Racibórz. Studies on carbon aerosol composition (OC, EC, TC) were carried out using the thermal-optical method, whereas the soot concentration (EBC) was determined using the optical method. The obtained results revealed significant differences in the concentrations of carbonaceous matter in PM2.5 along with clear seasonal variation. Seasonal variability of carbon aerosol concentrations is determined by increased emission of pollutants from fossil fuel combustion during the heating season as well as unfavorable meteorological conditions. The influence of the types of atmospheric circulation on concentrations of coal aerosol was also investigated. The obtained data indicate a significant impact of low-level and traffic emission sources on air quality.
Źródło:
Aktualne problemy w inżynierii i ochronie atmosfery; 230-237
9788374930208
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis and assessment of air quality in the city of Bialystok in 2012-2017
Autorzy:
Skoczko, I.
Szatyłowicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/96263.pdf
Data publikacji:
2018
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
air quality
air monitoring
NOx
PM2,5
PM10
jakość powietrza
monitorowanie powietrza
PM2.5
Opis:
The aim of the research was to assess the state of air pollution with mentioned pollution for the area of the city of Bialystok. The analysis was carried out using data from 2 air monitoring stations. The stations are owned by the Provincial Inspectorate for Environmental Protection in Bialystok. The work also compared the air quality in Bialystok with the air quality in the main voivodship cities with a similar population: Olsztyn, Lublin, Bydgoszcz and two of the largest urban agglomerations in the country: Warsaw and Wroclaw. It was found that the quality of air in the city of Bialystok compared to the analyzed cities is the best. In addition, it was observed that increased concentrations of PM10 and PM2.5 suspended dust occur in Bialystok in the months of X-III, due to the low emission from combustion of fuels.
Źródło:
Ekonomia i Środowisko; 2018, 2; 142-153
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Air Monitoring System in Megacity on the Example of St. Petersburg
Autorzy:
Dzhevaga, Natalia
Borisova, Darya
Powiązania:
https://bibliotekanauki.pl/articles/1839623.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
monitoring
air quality
environmental safety
dust
PM2.5
PM10
volatile organic compound
carbon oxide
nitrogen dioxide
Opis:
The paper considers the current problem of improving the quality of atmospheric monitoring. The paper aimed at conducting a monitoring section of the existing situation in the studied territories in St. Petersburg. The following study methods were described: gravimetric, electrochemical, and chromatographic. The analysis of samples was carried out on the following laboratory facilities of the mobile environmental laboratory: PU-3E aspirator, ECOLAB portable gas analyser, DUSTTRAK 8533 dust analyser, portable gas chromatograph FGKh-1, professional weather station. The study consisted of two parts and was carried out in two districts of the city: Novosmolenskaya Embankment of the Smolenka River (Vasileostrovsky District) and the banks of the Volkovka River (Frunzensky District). As a result of the study, the concentrations of nitrogen dioxide, carbon oxide, suspended solids and volatile organic compounds in the air of the studied districts were measured. The obtained values were compared with the maximal single limiting concentration (LMCm.s.) and assumptions were made about the possible sources of pollution. In the territory of Novosmolenskaya Embankment, the concentration of nitrogen dioxide varied from 0.211 mg/m3 to 0.472 mg/m3, which means the exceedance of LMCm.s. The maximum permissible concentration of the volatile organic compounds (VOC) content in air was exceeded by several orders of magnitude. No exceedance of LMCm.s. was detected for the content of carbon oxide and suspended solids in the air. The empirical data was used to build the air pollution content maps and to calculate the atmospheric pollution index in the studied territory.
Źródło:
Journal of Ecological Engineering; 2021, 22, 4; 175-185
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the data set from a two-year observation of the ambient water-soluble ions bound to four particulate matter fractions in an urban background site in Southern Poland
Autorzy:
Rogula-Kozłowska, W.
Majewski, G.
Czechowski, P. O.
Rogula-Kopiec, P
Powiązania:
https://bibliotekanauki.pl/articles/207331.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
chemical composition
inorganic ions
PM2.5
air
precipitation
atmosphere
Southern Poland
skład chemiczny
powietrze
paliwa stałe
zanieczyszczenie
Południe Polski
Opis:
Ten water-soluble ions (F, Cl, NO3, PO43–, SO42–, Na+, NH4+, K+, Ca2+, Mg2+), distributed among four fractions of particulate matter, PM, were investigated in an urban background site. The PM was sampled twice a week during a two-year sampling period. Mass distribution among the PM fractions and ambient concentrations of the ten PM-bound ions in the heating and non-heating periods, the seasonal effects in the PM fraction-bound ion concentrations (generalized regression model), and the principal components of all the resulting sets of ambient concentrations (principal component analysis) were determined, discussed, and interpreted in the terms of source apportionment of PM emissions. The formation of secondary inorganic aerosol in transformations of gaseous precursors (e.g., SOx, NOx, NH3) appeared to be most probable and significant source of PM2.5, especially of its sub-fraction PM1–2.5, in the non-heating period. In the heating period, PM and PM2.5 bound water-soluble ions originated mainly from combustion of coal and other solid fuels, or waste. Coarse particles (PM2.5–10 and PM10–40) and some PM2.5–40-bound ions (e.g. Na+, K+, Mg2+) may come from re-suspension of mineral matter and road dust. In some part, coarse PM may consist of mineral and salt particles containing gaseous and semi-volatile compounds.
Źródło:
Environment Protection Engineering; 2017, 43, 1; 137-149
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania zagrożenia środowiska cząstkami stałymi podczas eksploatacji pojazdów samochodowych
Testing of hazards to the environment caused by particulate matt er during use of vehicles
Autorzy:
Chłopek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1366279.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
pyły
cząstki stałe
PM10
PM2.5
PM1
pojazdy samochodowe
dusts
particulate matter
vehicles
Opis:
W pracy przedstawiono wyniki badań imisji frakcji pyłów PM10, PM2.5 i PM1. Do modelowania imisji frakcji cząstek stałych PM2.5 i PM1 wykorzystano wyniki badań empirycznych, przeprowadzonych na stacjach nadzorowania jakości powietrza w aglomeracji czeskiego miasta Brna. Wyniki modelowania imisji frakcji cząstek stałych PM2.5 i PM1 nie umożliwiły sformułowania jednoznacznych wniosków, co dowodzi konieczności statystycznego potraktowania badanego problemu. Stwierdzono jednak istotną zależność modeli imisji frakcji cząstek stałych od źródeł emisji pyłów i warunków ich rozprzestrzenia.
The study presents results of tests on emissions of fractions of PM10, PM2.5 and PM1 dusts. For modeling of emissions of fractions of PM2.5 and PM1 particles, results of empirical tests were used as carried out in air quality supervision stations located in the agglomeration of the city of Brno. The results of modeling of emissions of fractions of PM2.5 and PM1 particles did not make it possible to make unequivocal conclusions, which proves that the discussed problem has to be treated statistically. However, a significant relation between models of emissions of fractions of particulate matter and sources of emissions of dusts and conditions for distribution of the same were observed.
Źródło:
Eksploatacja i Niezawodność; 2012, 14, 2; 160-170
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wielopierścieniowych węglowodorów aromatycznych we frakcjach pyłów emitowanych z drukarek i kserokopiarek biurowych
The study of polycyclic aromatic hydrocarbons in particulate fractions emitted by office printers and copiers
Autorzy:
Szewczyńska, Małgorzata
Pośniak, Małgorzata
Kowalska, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/2166200.pdf
Data publikacji:
2015-02-25
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
wielopierścieniowe węglowodory aromatyczne
emisja z drukarek
emisja z kserokopiarek
frakcja PM10
frakcja PM2.5
polycyclic aromatic hydrocarbons
emission from printers
emission from copiers
fraction PM10
fraction PM2.5
Opis:
Wstęp: W artykule przedstawiono wyniki badań wielopierścieniowych węglowodorów aromatycznych (WWA) zaadsorbowanych na cząstkach drobnych emitowanych podczas pracy urządzeń powielających. Materiał i metody: Do badań wytypowano 3 rodzaje drukarek i 4 rodzaje kserokopiarek. Pomiary prowadzono w zamkniętej komorze pomiarowej, którą dodatkowo umieszczono pod wyciągiem laboratoryjnym. W komorze umieszczano urządzenia drukujące lub kopiujące oraz aspiratory połączone z próbnikami. Próbki powietrza pobierano na filtry teflonowe, umieszczone w próbnikach do pobierania frakcji pyłu drobnego (particulate matter – PM) PM 10 i PM 2,5. Analizę WWA osadzonych na cząstkach stałych, emitowanych z urządzeń powielających, prowadzono metodą wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (high pressure liquid chromatography with fluorescence detection – HPLC/FL). Wyniki: Wyniki analizy jakościowej wykazały obecność większości 10–14 wielopierścieniowych węglowodorów aromatycznych. Największe stężenie sumy WWA (36,52 μg×g -¹) oznaczono we frakcji PM 10 w powietrzu podczas pracy kserokopiarki. Sumaryczną zawartość WWA oznaczona we frakcji cząstek drobnych < 2,5 μm stanowią 48–84% zawartości WWA we frakcji < 10 μm w przypadku drukarek i 63–89% w przypadku kserokopiarek. Zarówno podczas pracy urządzeń drukujących, jak i powielających w obydwu frakcjach PM 2,5 oraz PM 10 zidentyfikowano benzo(a)piren (BaP). Maksymalne stężenie BaP we frakcji cząstek < 10 μm emitowanych z drukarki wynosiło 3,29±0,2 μg×g -¹. Wnioski: Badania wykazały, że stężenie emitowanych substancji zaadsorbowanych na PM 10 i PM 2,5 oraz stężenie tych cząstek w powietrzu nie jest stałe i zależy od rodzaju stosowanego urządzenia, rodzaju tonera i szybkości powielania. Emitowane do środowiska pracy cząstki drobne oraz osadzone na nich WWA mogą stanowić zagrożenie dla osób pracujących w ich otoczeniu. Med. Pr. 2014;65(6):733–741
Background: This article presents the study of polycyclic aromatic hydrocarbons (PAHs) adsorbed on fine particles emitted during the simulated operation of office printers and copiers. Material and Methods: In the study three types of printers, and four types of office copiers were used. Measurements were carried out in a closed measuring chamber. Air samples (fractions of particulate matter, PM 10 and PM 2.5) were collected on Teflon filters. The analysis of PAHs was carried out according HPLC/FL. Results: The results of qualitative analysis of filters from PM 2.5 and PM 10 type samplers indicated the presence of the majority (10–14) of PAH congeners. The highest concentration of total PAHs was determined in the PM 10 fraction in the air during the operation of a copier, and amounted to 36.52 μg×g -¹. The total content of PAHs as determined in the fraction of fine particulates, size of < 2.5 μm, accounts for 48–84% of the PAH content in the < 10 μm fraction for printers and 63–89% for copiers. During the operation of both printers and copiers, benzo(a)pirene (BaP) was identified in both fractions, PM 2.5 and PM 10. The maximum concentration of BaP in the fraction of < 10 μm particles emitted by a printer amounted to 3.29±0.2 μg×g -¹. Conclusions: The studies showed that the composition of emitted substances and fine particles depends on the type of equipment and technology used. Fine particles emitted to the environment and organic compounds, including PAHs adsorbed on them may pose a threat to people working in such an environment. Med Pr 2014;65(6):733–741
Źródło:
Medycyna Pracy; 2014, 65, 6; 733-741
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies