Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "PM1" wg kryterium: Temat


Wyświetlanie 1-14 z 14
Tytuł:
Ocena jakości powietrza wewnątrz budynku szkolnego. Studium przypadku z Wrocławia
Evaluation of air quality inside a school building. A case study from Wroclaw, Poland
Autorzy:
Zwoździak, Anna
Zwoździak, Jerzy
Sówka, Izabela
Powiązania:
https://bibliotekanauki.pl/articles/1035358.pdf
Data publikacji:
2017
Wydawca:
Instytut Medycyny Wsi
Tematy:
"PM1
"PM10"
"PM2.5"
"powietrze wewnętrzne"
"szkoła"
0"
Opis:
In order to achieve good air quality in schools, where children spend ca. 6–8 hours per day, and to find solutions for improving it, indoor pollution has to be accurately evaluated. Children are among the groups most vulnerable to the adverse effects of PM. Our study focuses on the characterization of different fractions of PM (PM1.0, PM2.5, PM10) measured inside and outside the building of a secondary school in Wroclaw, Poland, located in the centre of the city. PM1.0, PM2.5, and PM10 samples, from indoor (I) and outdoor (O) air, were collected using Harvard cascade impactors during the years 2009/2010. The study revealed that on 90% of days in the wintertime,24h indoor PM2.5 and PM10 concentrations were higher than the WHO air quality guidance values for ambient air. The PM2.5 fraction found inside the school in winter and the PM10 fraction both in winter and summer resulted mostly from indoor rather than outdoor sources, as shown by the I/O ratio of 1.2 for 24-hour mean of PM2.5 and 1.3, and 2.0 for 24-hour mean of PM10 in winter and summer, respectively. However, PM2.5 and PM10 concentrations during teaching hours (8-hour mean) were much higher than outdoors (2.0 and 2.5 times in winter and 4.1 and 5.6 times in summer, respectively). PM1 concentrations reached comparable levels indoors and outdoors. These data can be considered as preliminary; however, they may act as a stimulus for future studies aiming to estimate the effect of indoor PM concentrations on the respiratory system in schoolchildren.
W celu osiągnięcia dobrej jakości powietrza w szkole, gdzie dzieci spędzają ok. 6–8 godzin dziennie i znalezienia rozwiązania, by ją poprawić, należy dokładnie rozpoznać problem zanieczyszczenia powietrza wewnętrznego. Dzieci są jedną z bardziej wrażliwych grup, wśród których obserwuje się szkodliwe oddziaływanie pyłów zawieszonych na zdrowie. Nasze badania skupiły się na charakterystyce zanieczyszczenia powietrza różnymi frakcjami pyłu zawieszonego (tj. PM1,0, PM2,5, PM10) wewnątrz (W) i na zewnątrz (Z) budynku szkoły gimnazjalnej w centrum Wrocławia. Do poboru próbek pyłu PM1,0, PM2,5 i PM10, w latach 2009/2010, zostały wykorzystane impaktory typu Harvard.Zimą, w 90 dni pomiarowych, stwierdzono przekroczenia zalecanych przez WHO średnich dobowych stężeń PM10 i PM2,5. Frakcja PM2,5 wewnątrz szkoły oraz frakcja PM10, zarówno zimą, jak i latem miały swoje źródła w samej szkole, o czym świadczył stosunek W/Z = 1,2 dla średnich dobowych stężeń PM2,5, i odpowiednio 1,3 (zimą) oraz 2,0 (latem) dla PM10. Jednak, stężenia PM2,5 and PM10 w czasie trwania zajęć szkolnych (8-godzinne średnie) były znacznie wyższe (odpowiednio: 2,0 i 2,5-krotnie zimą oraz 4,1 i 5,6-krotnie latem). Stężenia PM1 były porównywalne wewnątrz i na zewnątrz szkoły. Choć są to badania wstępne, to jednak powinny zmotywować do dalszych prac skupionych na ocenie relacji między stężeniem pyłów drobnych w szkole a reakcjąukładu oddechowego dzieci.
Źródło:
Medycyna Środowiskowa - Environmental Medicine; 2017, 20, 3; 36-43
1505-7054
2084-6312
Pojawia się w:
Medycyna Środowiskowa - Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena zagrożenia środowiska cząstkami stałymi ze źródeł cywilizacyjnych
Environmental risk assessment of particulate matter from civilization sources
Autorzy:
Chłopek, Z.
Szczepański, T.
Powiązania:
https://bibliotekanauki.pl/articles/400453.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
cząstki stałe
PM10
PM2.5
PM1
particulate matter
Opis:
W artykule opisano główne problemy ekologiczne związane z pyłami. Przedstawiono klasyfikację wymiarową pyłów: cząstki stałe PM10, PM2.5 i PM1. Opisano źródła emisji cząstek stałych i ich wpływ na zdrowie ludzi i na środowisko. Przedstawiono sposoby modelowania emisji i imisji frakcji wymiarowych cząstek stałych. Przedstawiono wyniki identyfikacji modeli imisji cząstek stałych PM2.5 i PM1. W wyniku przeprowadzonych badań oceniono, że nie ma podstaw do stwierdzenia, iż dominującym źródłem pyłów drobnych jest motoryzacja.
This paper describes the main environmental problems related to dust. The classification of dimensional dust: particulate matter PM10, PM2.5 and PM1, has been presented. The sources of particulate emission and their impact on human health and the environment have been described. The paper presents methods for modeling the emission and immission fraction dimensional particulate. The results of model identification of immission particles PM2.5 and PM1 have been presented. The research found that there is no basis to conclude that the dominant source of fine dust is the car industry.
Źródło:
Inżynieria Ekologiczna; 2012, 30; 174-193
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania zagrożenia środowiska cząstkami stałymi podczas eksploatacji pojazdów samochodowych
Testing of hazards to the environment caused by particulate matt er during use of vehicles
Autorzy:
Chłopek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1366279.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
pyły
cząstki stałe
PM10
PM2.5
PM1
pojazdy samochodowe
dusts
particulate matter
vehicles
Opis:
W pracy przedstawiono wyniki badań imisji frakcji pyłów PM10, PM2.5 i PM1. Do modelowania imisji frakcji cząstek stałych PM2.5 i PM1 wykorzystano wyniki badań empirycznych, przeprowadzonych na stacjach nadzorowania jakości powietrza w aglomeracji czeskiego miasta Brna. Wyniki modelowania imisji frakcji cząstek stałych PM2.5 i PM1 nie umożliwiły sformułowania jednoznacznych wniosków, co dowodzi konieczności statystycznego potraktowania badanego problemu. Stwierdzono jednak istotną zależność modeli imisji frakcji cząstek stałych od źródeł emisji pyłów i warunków ich rozprzestrzenia.
The study presents results of tests on emissions of fractions of PM10, PM2.5 and PM1 dusts. For modeling of emissions of fractions of PM2.5 and PM1 particles, results of empirical tests were used as carried out in air quality supervision stations located in the agglomeration of the city of Brno. The results of modeling of emissions of fractions of PM2.5 and PM1 particles did not make it possible to make unequivocal conclusions, which proves that the discussed problem has to be treated statistically. However, a significant relation between models of emissions of fractions of particulate matter and sources of emissions of dusts and conditions for distribution of the same were observed.
Źródło:
Eksploatacja i Niezawodność; 2012, 14, 2; 160-170
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An assessment of PM1 levels based on indicative PM1 measurements and relationships with PM10 and PM2.5 concentrations, for the analysis of hospital admissions and mortality in the Moravian region
Autorzy:
Šlachtová, Hana
Tomášek, Ivan
Polaufová, Pavla
Hellebrandová, Lucie
Šplíchalová, Anna
Tomášková, Hana
Powiązania:
https://bibliotekanauki.pl/articles/2081904.pdf
Data publikacji:
2021-06-30
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
PM 1 concentrations
spatiotemporal PM variations
heating season differences
air pollution
PM 2.5 concentrations
PM 10 concentrations
Opis:
Particulate matter (PM) air pollution is a serious concern in the city of Ostrava. Thus, in 2018, a project entitled “Validation of the relationships between PM10, PM2.5 and PM1 concentrations, and morbidity and mortality, in the heavily polluted region in the Czech Republic,” was launched. The relationship between hospital admissions and mortality in the said region is based primarily on short-term PM10 and PM2.5 concentrations and indicative PM1 measurement. The analysis of spatiotemporal variations and the relationship between PM10, PM2.5 and PM1 data from 3 measurement sites within the city of Ostrava is presented.Material and MethodsThe analysis was based on the daily average PM concentrations for 5 and 6 months at 2 sites, and on the annual average values (2018–2019) at the baseline station. The correlations of and variability between PM fractions, seasonal differences and explanation of the differences found were the objectives of a detailed analysis. Especially, the potential PM1 variability and its causes were analyzed with respect to the location of the site.ResultsThe study findings confirmed good correlations between the PM fractions. Compared to PM10, PM2.5 concentrations were more predictive for PM1 concentrations. The annual means of PM10, PM2.5 and PM1 reached 37.5, 29.9 and 27.1 μg/m3 in 2018, respectively, and 25.8, 19.9 and 17.9 μg/m3 in 2019, respectively. The concentration levels in the non-heating season were significantly lower than in the heating season in the 2 years under consideration. The levels of PM10, PM2.5 and PM1 were significantly correlated (the correlation coefficient, r > 0.96). The levels of PM2.5 represented about 0.82–0.86 of PM10, and the levels of PM1 about 0.92–0.93 of PM2.5. These ratios were found to differ in the heating and non-heating seasons, with the PM2.5–PM10 ratio ranging 0.61–0.63 in the non-heating seasons.ConclusionsThe correlations found will be used for indicative PM1 measurements in other areas of the region. Seasonal variability should be taken into account as well. Med Pr. 2021;72(3):249–58
Źródło:
Medycyna Pracy; 2021, 72, 3; 249-258
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PM10, PM25 and PM10 Indoor and Outdoor Concentrations and Chemical Composition in School Environment
Stężenia oraz skład chemiczny pyłu PM10, PM25 oraz PM10 w powietrzu wewnętrznym i zewnętrznym szkoły
Autorzy:
Zwoździak, A.
Sówka, I.
Skrzętowicz, M.
Worobiec, A.
Nych, A.
Zwoździak, J.
Grieken, R.
Powiązania:
https://bibliotekanauki.pl/articles/389676.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
PM1.0
PM2.5
PM10
powietrze wewnętrzne i zewnętrzne
skład elementarny
PM10 indoor-outdoor particles
elemental composition
Opis:
Simultaneous daily indoor and outdoor measurements of PM1.0, PM2.5, PM10 have been conducted during winter season of 2009/2010 in the secondary school in Wroclaw, Poland. Aerosol samples were analysed for mass concentrations and elemental composition. The factor analysis was applied to identify possible emission sources of the PM1.0 fraction. Mean daily PM10 concentrations was 81 g/m3 indoors and 54 g/m3 outdoors. The corresponding means for PM2.5 and PM1.0 were 62 and 22 g/m3 indoors and 46 and 24 g/m3 outdoors. There were reported 90 % of days with daily mean exceeding the WHO AQG for PM2.5 – 25 g/m3. In many cases the I/O ratio was higher than 1.0, what means that there are some particles sources inside the school building, particularly for the fractions PM10 and PM2.5. The most abundant elements in the PM1.0 fraction were S, Cl and K. Zn and Pb were the dominant heavy metals. Combustion processes contributed to high concentrations of K, S, As, Cl and vehicular emission to Cu, Pb and Zn.
Jednoczesne pomiary stężeń pyłu PM1.0, PM2.5, PM10 w powietrzu wewnętrznym i zewnętrznym zostały przeprowadzone w szkole średniej we Wrocławiu w sezonie zimowym 2009/2010 roku. Pobrane próbki aerozolu analizowano pod względem wysokości stężenia masowego oraz składu pierwiastkowego. Analizę czynnikową wykorzystano do oceny źródeł pochodzenia cząstek frakcji PM1.0. W powietrzu wewnętrznym średnie dobowe stężenie PM10 wynosiło 81 g/m3, a zewnętrznym 54 g/m3. Odpowiednie średnie dla PM2.5 i PM1.0 wynosiły 62 i 22 g/m3 wewnątrz i 46 i 24 g/m3 na zewnątrz budynku. Na podstawie przeprowadzonych pomiarów odnotowano 90 % dni ze średnim dobowym stężeniem frakcji PM2.5 powyżej wartości zalecanej w wytycznych Światowej Organizacji Zdrowia, tj. 25 g/m3. W wielu przypadkach stosunek stężeń w powietrzu wewnętrznym (I) do stężeń w powietrzu zewnętrznym (O), tj. I/O, był większy od 1.0, co oznaczało istnienie źródeł pyłów wewnątrz budynku, a dotyczyło do przede wszystkim frakcji PM10 i PM2.5. We frakcji PM1.0 w największych koncentracjach pojawiały się S, Cl i K, a wśród metali ciężkich Zn i Pb. Procesy spalania miały największy udział w stężeniach K, S, As i Cl, natomiast motoryzacja w przypadku stężeń Cu, Pb i Zn.
Źródło:
Ecological Chemistry and Engineering. A; 2011, 18, 7; 933-940
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hazardous Compounds in Urban Pm in the Central Part of Upper Silesia (Poland) in Winter
Niebezpieczne związki w miejskim pyle zawieszonym w centralnej części Górnego Śląska w zimie
Autorzy:
Rogula-Kozłowska, W.
Kozielska, B.
Klejnowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/204935.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pył zawieszony
pył PM2,5
pył PM1
metale ciężkie
WWA
wielopierścieniowe węglowodory aromatyczne
związki rakotwórcze
jakość powietrza
Zabrze
PM1
PM2,5
heavy metals
PAH
benzo(a)pyrene
carcinogenicity
hazardous compounds
toxicity equivalency factor
BEQ
Opis:
Thirteen fractions of ambient dust were investigated in Zabrze, a typical urban area in the central part of Upper Silesia (Poland), during a heating season. Fifteen PAH and Cr, Mn, Co, Ni, As, Se, Cd, Pb contents of each fraction were determined. The dust was sampled with use of a cascade impactor and chemically analyzed with an energy dispersive X-ray fl uorescence spectrometer (PANalytical Epsilon 5) and a gas chromatograph with a fl ame ionisation detector (Perkin Elmer Clarus 500). The concentrations of PM1 and the PM1-related PAH and elements were much higher than the ones of the coarse dust (PM2.5-10) and the substances contained in it. The concentrations of total PAH and carcinogenic PAH were very high (the concentrations of PM1-, PM2.5-, and PM10-related BaP were 16.08, 19.19, 19.32 ng m-3, respectively). The municipal emission, resulted mainly from hard coal combustion processes, appeared to be the main factor affecting the air quality in Zabrze in winter.
Próbki trzynastu frakcji pyłu zawieszonego były pobierane w Zabrzu w okresie grzewczym (centralna część Górnego Śląska, Polska). Punkt poboru jest charakterystyczny dla obszaru miejskiego. Zbadano zawartość 15 WWA oraz Cr, Mn, Co, Ni, As, Se, Cd, Pb w każdej frakcji pyłu. Do poboru pyłu zastosowano impaktor kaskadowy, a do analizy chemicznej – spektrometr fl uorescencji rentgenowskiej z dyspersją energii (PANalytical Epsilon 5) oraz chromatograf gazowy z detektorem płomieniowo-jonizacyjnym (Perkin Elmer Clarus 500). Zarówno stężenia pyłu PM1 jak i stężenia związanych z nim WWA i pierwiastków były znacznie wyższe niż stężenia pyłu grubego (PM2.5-10) i związanych z nim substancji. Stężenia sumy WWA, a w szczególności kancerogennych związków tej grupy były bardzo wysokie (np. stężenia dla BaP związanego z PM1- i PM2.5- oraz PM10- wynosiły odpowiednio: 16.08, 19.19, 19.32 ng m-3). Na podstawie uzyskanych wyników badań dla ww. zanieczyszczeń stwierdzono, że za stan jakości powietrza w Zabrzu, w zimie, odpowiedzialna jest emisja komunalna – stacjonarne źródła spalania, głównie spalanie węgla.
Źródło:
Archives of Environmental Protection; 2013, 39, 1; 53-65
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transport of Microbial Components in Coarse and Fine Particle Fractions in Office Buildings
Transport cząstek pochodzenia mikrobiologicznego w drobnej i grubej frakcji aerozolu w budynkach biurowych
Autorzy:
Ławniczek-Wałczyk, Anna
Górny, Rafał L.
Powiązania:
https://bibliotekanauki.pl/articles/1812026.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
office
endotoxins
β-D-glucans
PM1
PM2.5
PM2.5-10
bioaerosol
biuro
endotoksyny
β-D-glukany
bioaerozol
Opis:
In old and modern interiors, particular attention is focused on the air quality as one of major determinants of the well-being of occupants. Exposure to microbiological contaminants in such close indoor space may be associated with the occurrence of various adverse health outcomes in the exposed individuals. Because the size of inhaled particles determines their place of deposition in the human airways and the associated adverse health outcomes, a detailed characteristic of airborne microbial components carried on fine dust particles in office buildings is needed. The aim of this study was to determine the concentrations of endotoxins, (1-3)-β-D-glucans and culturable microorganisms in coarse, fine and aerosol fractions collected in two office buildings in Warsaw. The concentrations of particulate aerosol were measured using Sioutas impactors in PM1, PM2.5, and PM2.5-10. Kinetic-QCL LAL and Glucatell assays were used to detect endotoxin and (1-3)-β-D-glucan concentrations, respectively. The bioaerosol samples were taken using six-stage Andersen impactor as coarse (> 7-2.1µm) and fine (< 2.1µm) fractions, as well. The mean concentrations of particulate aerosol, endotoxins and (1-3)-β-D-glucans in all studied offices were: in PM1 – 6 μg/m3, 4 EU/m3 and 5 ng/m3; in PM2.5 – 11 μg/m3, 6 EU/m3 and 10 ng/m3; and PM10-2.5 – 3.5 μg/m3, 2 EU/m3 and 2.5 ng/m3, respectively. The concentrations of endotoxins and (1-3)-β-glucans in PM2.5 were significantly higher than in PM10-2.5 (p < 0.01 and p < 0.001, respectively) and accounted for 71% and 84% of their total load in PM10. The airborne bacteria occurred mostly in fine fraction (average 3.9 · 102 CFU/m3, p < 0.01), while fungi in coarse fraction of aerosol (5.6 · 101 CFU/m3). The concentrations of endotoxins showed a positive correlation with PM1 (r = 0.61, p < 0.05) and PM2.5 levels (r = 0.76, p < 0.05) as well as with Gram-negative rods in fine fraction (r = 0.75, p < 0.05). The concentrations of (1-3)-β-D-glucans showed positive correlation with PM2.5 (r = 0.54, p < 0.05) and fungi in fine fraction (r = 0.59, p < 0.05). This study demonstrated that endotoxins and (1-3)-β-D-glucans are associated mostly with fine fraction of aerosol particles. Such particles can penetrate the lower parts of the human respiratory system posing a health risk for exposed people. The main source of endotoxins in the offices were Gram-negative rods. The sources of (1-3)-β-D-glucans were probably both fungal conidia and their fragments of aerodynamic diameters <2.1 μm. The noted concentrations of endotoxins and microorganism were within the range normally observed in this type of facilities. Nevertheless, constant monitoring of the hygienic condition is suggested, including regular cleaning and replacement of air filters in the air-conditioning system.
Zarówno w starych, jak i nowoczesnych wnętrzach budynków biurowych szczególną uwagę zwraca się na jakość powietrza, która jest wyznacznikiem dobrostanu mieszkańców. Narażenie na zanieczyszczenia mikrobiologiczne w takich zamkniętych pomieszczeniach może być związane z pojawianiem się różnych niekorzystnych efektów zdrowotnych u narażonych osób. Ponieważ wielkość wdychanych cząstek determinujeich miejsce osadzania w drogach oddechowych człowieka i związane z tym problemy zdrowotne, potrzebna jest szczegółowa charakterystyka frakcji cząstek pyłowych transportujących cząstki pochodzenia mikrobiologicznego w budynkach biurowych. Celem niniejszego badania było poznanie zakresów stężeń endotoksyn, (1-3)-β-D-glukanów i mikroorganizmów w drobnej i grubej frakcji aerozolu ziarnistego w dwóch budynkach biurowych w Warszawie. Stężenia aerozolu ziarnistego zmierzono przy użyciu impaktorów Sioutas we frakcjach PM1, PM2.5 i PM2.5-10. Testy Kinetic-QCL LAL i Glucatell zastosowano odpowiednio do detekcji endotoksyn i β-D-glukanów. Próbki biaerozolu pobrano przy użyciu sześcio-stopniowego impaktora Andersena we frakcji gruboziarnistej (> 7-2,1 μm) i drobnej (< 2,1 μm). Średnie stężenia aerozolu ziarnistego, endotoksyn i β-D-glukanów w wszystkich badanych biurach wynosiły odpowiednio: w PM1 – 6 μg/m3, 4 JE/m3 i 5 ng/m3; w PM2.5 – 11 μg/m3, 6 JE/m3 i 10 ng/m3 i w PM10-2.5 – 3.5 μg/m33, 2 JE/m3 i 2.5 ng/m3. Stężenia endotoksyn i β-D-glukanów w PM2.5 były znacznie wyższe niż w PM10-2.5 (odpowiednio p < 0.01 i p < 0.001) i stanowiły 71% i 84% frakcji PM10. W badanych pomieszczeniach, bakterie występowały głównie w drobnej frakcji aerozolu (3.9·102 JTK/m3, p < 0.01), podczas gdy grzyby izolowano najczęściej z frakcji gruboziarnistej aerozolu (5.6·101 JTK/m3). Stwierdzono pozytywną korelację pomiędzy stężeniami endotoksyn a stężeniami pyłu PM1 (r = 0.61, p < 0.05) i PM2.5 (r = 0.76, p < 0.05), jak również Gram-ujemnymi pałeczkami (r = 0.75, p < 0.05). Stężenia β-D-glucans wykazały korelację z PM2.5 (r = 0.54, p < 0.05) oraz grzybami w drobnej frakcji (r = 0.59, p < 0.05). Niniejsze badania wykazały, że głównym nośnikiem endotoksyn i (1-3)-β-Dglukanów w pomieszczeniach biurowych były drobne frakcje aerozolu ziarnistego. Cząstki te mogą przenikać do dolnych dróg oddechowych powodując niekorzystne skutki zdrowotne u narażonych osób. Stwierdzono, że głównym źródłem endotoksyn były Gram-ujemne pałeczniki. Źródłami (1-3)-β-D-glukanów były głównie fragmenty strzępek grzybni (lub spor) o aerodynamicznych średnicach <2,1 μm. Odnotowane stężenia endotoksyn i mikroorganizmów w biurach mieściły się w zakresie normalnie obserwowanym w tego typu obiektach. Niemniej jednak sugerowane jest stałe monitorowanie stanu higienicznego tych pomieszczeń, w tym regularne czyszczenie i wymienianie filtrów powietrza w instalacji klimatyzacyjnej.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 2; 1099-1115
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Do we know PM1 in Poland inside out?
Autorzy:
Rogula-Kozłowska, Wioletta
Powiązania:
https://bibliotekanauki.pl/articles/28407390.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
PM1
carcinogenic compounds
particulate matter
health effect
związki rakotwórcze
cząstki stałe
efekt zdrowotny
Opis:
The paper provides a concise review of key publications on particulate matter of aerodynamic diameter below 1 μm (PM1) having been published in Poland in the years 2007–2022. Data and conclusions related to the study of concentrations, chemical composition, and content of selected toxic and carcinogenic compounds in PM1 as well as methods and conclusions on the assessment of the origin of PM1 in various regions of Poland have been tabulated. The conclusions of this review attempt to outline the directions of further research that could prove crucial in obtaining information and filling the identified gaps in knowledge about PM1 in Poland. While this work may be theoretical, it can serve as a valuable and compact source material for research groups, organizations supervising and financing research, as well as those responsible for assessing air quality and mitigating negative health effects related to air quality.
Źródło:
Environment Protection Engineering; 2023, 49, 4; 5--27
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytm steganograficzny PM1 wykorzystujący trójkowy kod Hamminga
PM1 steganographic algorithm using ternary Hamming Code
Autorzy:
Kaczyński, K.
Powiązania:
https://bibliotekanauki.pl/articles/210195.pdf
Data publikacji:
2015
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
steganografia
kody liniowe
PM1
LSB
trójkowy kod Hamminga
steganography
linear codes
ternary Hamming code
Opis:
Algorytm PM1 jest rozwinięciem algorytmu LSB, cechującym się nie tylko zwiększoną odpornością na ataki stegoanalityczne, lecz także wysoką pojemnością steganograficzną. Algorytm PM1 dzięki swojej unikalności pozwala na wykorzystanie szerszego alfabetu symboli, co umożliwia dodatkowe zwiększenie pojemności steganograficznej nośnika. W niniejszym artykule przedstawiony zostanie zmodyfikowany algorytm PM1, w ktorym zastosowano tzw. kodowanie syndromami poprzez wykorzystanie trojkowego kodu Hamminga. Zabieg ten pozwolił na zmniejszenie liczby wprowadzanych do nośnika zmian, przy jednoczesnym zwiększeniu jego pojemności.
PM1 algorithm is a modification of well-known LSB steganographic algorithm. It has increased resistance to selected steganalytic attacks and increased embedding efficiency. Due to its uniqueness, PM1 algorithm allows us to use of larger alphabet of symbols, making it possible to further increase steganographic capacity. In this paper, we present the modified PM1 algorithm which utilizies so-called syndrome coding and ternary Hamming code. The modified algorithm has increased embedding efficiency, which means fewer changes introduced to carrier and increased capacity.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2015, 64, 4; 257-267
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stężenie oraz skład elementarny cząstek pyłu zawieszonego w powietrzu wewnętrznym wybranej szkoły i w atmosferze Wrocławia
Indoor and outdoor air particulate matter concentrations and chemical composition in naturally yentilated school enyironment and Wroclaws atmosphere
Autorzy:
Sówka, I.
Zwoździak, A.
Skrętowicz, M.
Worobiec, A.
Nych, A.
Grieken, R.
Zwoździak, J.
Powiązania:
https://bibliotekanauki.pl/articles/125717.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
PM1.0
PM2.5
PM10
powietrze wewnętrzne
powietrze zewnętrzne
skład elementarny cząstek pyłu w powietrzu
PM10 indoor-outdoor particles
elemental composition
Opis:
Pomiary stężeń pyłu PM1.0, PM2.5, PM10 zostały przeprowadzone w okresie zimowym 2009 i 2010 roku w szkole średniej oraz na obszarach miejskich we Wrocławiu. Pobrane w powietrzu wewnętrznym oraz zewnętrznym próbki aerozolu analizowano pod względem poziomu stężenia oraz składu pierwiastkowego. W powietrzu wewnętrznym stężenia PM 1.0, PM2.5 i PM10 wyniosły kolejno: 13-36, 18+143 oraz 21-190 ug/m3. Pomiary wykazały, że w powietrzu zewnętrznym stężenia pyłu zawieszonego były mniejsze i mieściły się w granicach: 15-41 (PM1.0), 24-79 (PM2.5) oraz 26-95 Hg/m3 (PM10). Jakość powietrza we Wrocławiu oceniono zgodnie w wytycznymi Jakości Powietrza Światowej Organizacji Zdrowia (WHO AQO). Na podstawie przeprowadzonych obliczeń odnotowano 90% dni ze średnią dobową powyżej wartości stężeń określonych w ww. wytycznych: w przypadku frakcji PM2.5 - 25 ug/m3. Zmierzone we Wrocławiu stężenia PM2.5 w zakresie 24-79 ug/m3 mogą zatem wskazywać na wzrost ryzyka zachorowalności związanej z zanieczyszczeniem powietrza pyłem zawieszonym.
The measurements of PM1.0, PM2.5, PMIO have been conducted during the winter season of 2009 and 2010 in the secondary school and over urban area in Wrocław, Poland. Both, indoor and outdoor aerosol samples were analyzed for their weight and elemental composition. Indoor PM1.0, PM2.5 and PMIO concentrations ranged 13-36, 18-143 and 21-190 Hg/m3, respectively. The results showed that outdoor particulate matter concentrations were lower than indoor one and ranged 15-41 (PM1.0), 24-79 (PM2.5), and 26-95 ug/m3 (PMIO). Air quality in Wrocław has been categorized according to World Health Organization Air Quality Guideline (WHO AQG). There were reported 90% of days with daily mean exceeding the WHO AQG for PM2.5 - 25 ug/m3. Within the measured concentration range 24-79 ug/m3 a significant daily increase in morbidity risk has been deduced.
Źródło:
Proceedings of ECOpole; 2011, 5, 2; 617-622
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Emisja stałych cząstek z liniowych źródeł zanieczyszczenia jako główny czynnik wpływający na poziom stężenia pyłu zawieszonego PM10, PM2,5, PM1,0 w powietrzu atmosferycznym aglomeracji warszawskiej
Emissions of Solid Particles from Linear Sources of Pollution as a Major Factor in the Level of Concentration of PM10, PM2.5, PM1.0 in Ambient Air of Warsaw Agglomeration
Autorzy:
Dmochowski, D.
Dmochowska, A.
Biedugnis, S.
Powiązania:
https://bibliotekanauki.pl/articles/1818580.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
emisja pyłów ze źródeł liniowych zanieczyszczenia
stężenie pyłu PM10
PM2.5
PM1.0
dust emissions from linear sources of pollution
level concentrations of PM10
Opis:
The paper presents the results of the research into the dust from the linear sources of pollution emitted close to the right-bank Warsaw allotments. The results of dust measurements and its fraction show that the legal limits of the concentration of dusts floating in the atmospheric air for the measurement points are exceeded. The points are located in the nearest distance from Trasa Łazienkowska and alley Waszyngtona – two busy roads in the right-bank Warsaw. The results show that the dust and its fractions can pose the ecological safety hazards and can constitute a significant reduction of health safety of both allotments users and local residents.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 1403-1412
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental and Computational Vibration Study of Amino Acids
Autorzy:
Mohammed, M. E.
Mohamed, A. M. A.
Powiązania:
https://bibliotekanauki.pl/articles/412478.pdf
Data publikacji:
2013
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Vibrational studies
Amino Acids
semi-empirical methods (PM6 and RM1)
ab initio methods (B3LYP/6-31+G(d)
Opis:
Vibrational studies of amino acids experimentally and theoretically have been performed. The Semi-empirical methods optimization by PM6 and RM1 on the l- and d-amino acids (alanine, phenylalanine, aspartic and glutamic acid), showed no difference in energy between l-and d-isomers. The vibrational frequencies were calculated by semi-emprical methods (PM6 and RM1) and ab initio methods (B3LYP/6-31+G(d) and were scaled down by factors of 0.925 (RM1), 1.09 (PM6) and 0.89 (B3LYP/6-31+G(d)). The calculated and experimental vibrational frequencies have shown good general agreement.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2013, 10, 1; 1-17
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wyników pierwszej w Polsce kampanii pomiarowej składu pyłu zawieszonego w wysokiej rozdzielczości czasowej (pobornik Streaker)
ANALYSIS OF THE RESULTS OF THE FIRST MEASUREMENT CAMPAIGN OF PM ELEMENTAL COMPOSITION IN HIGH TIME RESOLUTION IN POLAND (STREAKER SAMPLER)
Autorzy:
Reizer, Magdalena
Maciejewska, Katarzyna
Juda-Rezler, Katarzyna
Powiązania:
https://bibliotekanauki.pl/chapters/16729248.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
pył zawieszony
PM2.5
PMc
pierwiastki śladowe
stężenia 1-godzinne
pobornik Streaker
analiza PIXE
identyfikacja źródeł
PMF
Warszawa
Opis:
Celem pracy jest identyfikacja źródeł pyłu zawieszonego (PM) oraz analiza dobowego profilu składników pyłu, z wykorzystaniem danych o wysokiej 1-godzinnej rozdzielczości czasowej uzyskanych w ramach, przeprowadzonej po raz pierwszy w Polsce i w Europie Środkowo-Wschodniej, kampanii pomiarowej w punkcie tła miejskiego w Warszawie. Próbki PM2,5 i PMc zostały zebrane za pomocą dwustopniowego pobornika Streaker (PIXE International Corporation). Analiza filtrów z wykorzystaniem techniki analizy emisji promieniowania X wzbudzonego przez cząstki – protony PIXE (ang. Particle Induced X-ray Emission) pozwoliła na uzyskanie stężeń masowych 27 pierwiastków w 1-godzinnej rozdzielczości czasowej. Kampania pomiarowa została przeprowadzona w okresie od 18 lutego do 10 marca 2016 r. Identyfikacja źródeł dla obu frakcji PM przeprowadzona za pomocą modelu EPA PMF umożliwiła określenie 7 źródeł PM2,5 oraz 5 źródeł PMc. Transport drogowy był głównym źródłem PMc (82% udziału), natomiast wtórny aerozol siarczanowy miał największy udział we frakcji drobnej (44%). Dobowe profile pierwiastków związanych z głównymi źródłami PM w Warszawie charakteryzowały się bimodalnym przebiegiem o maksymalnych stężeniach w godzinach porannych i popołudniowych.
The aim of present work is identification of particulate matter (PM) sources and analysis of daily profile of PM components using data with high 1-hour time resolution at urban background site in Warsaw, for the first time in Poland. Fine (PM2,5) and coarse (PMc) fractions of PM have been collected by a two-stage Streaker sampler (PIXE International Corporation). The filters have been analysed by Particle Induced X-ray Emission (PIXE) technique to obtain mass concentrations of 27 elements with hourly resolution. The measurement campaign were performed from 18th February to 10th March 2016. Source apportionment of fine and coarse PM fractions estimated by EPA PMF model allowed for the identification of 7 and 5 sources of PM2,5 and PMc, respectively. Traffic was found as the major source (82% share) in the coarse fraction, while fuel combustion in residential sector have the biggest share (44%) in the fine fraction. Daily profiles of elements in major PM sources showed the bimodal patterns with peak concentrations during morning and afternoon hours.
Źródło:
Aktualne problemy w inżynierii i ochronie atmosfery; 190-197
9788374930208
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies