Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "PEF" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
New methods for inactivation of Alicyclobacillus acidoterrestris spores in apple juice concentrate
Autorzy:
Djas, M.
Bober, M.
Henczka, M.
Powiązania:
https://bibliotekanauki.pl/articles/115690.pdf
Data publikacji:
2011
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Tematy:
Alicyclobacillus acidoterrestris
spores
inactivation
pulsed electric field (PEF)
ultrasound (US)
microwaves (MW)
Opis:
This paper is focused on new methods for inhibiting Alicyclobacillus acidoterrestris spores germination in apple juice concentrate. Four methods such as pulsed electric field (PEF), ultrasound (US), integrated method of PEF and US and microwaves (MW) have been investigated. The highest efficiency of spores inactivation was obtained after microwave treatment.
Źródło:
Challenges of Modern Technology; 2011, 2, 2; 46-49
2082-2863
2353-4419
Pojawia się w:
Challenges of Modern Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modification of substandard EPDM with amorphous thermoplastic polyesters (PETG and PEF): microstructure and physical properties
Autorzy:
Paszkiewicz, S.
Irska, I.
Piesowicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/780004.pdf
Data publikacji:
2018
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
polymer blends
substandard EPDM
PETG
PEF
phase morphology
mechanical properties
thermal stability
Opis:
The phase morphology, thermal behavior and mechanical properties of two series of polymer blends based on ethylene/propylene/diene rubber (EPDM) and amorphous homologues of poly(ethylene terephthalate), i.e. glycol modifi ed poly(ethylene terephthalate) (PETG) and poly(ethylene furanoate) (PEF), were investigated. The morphology of the blends shows a two phase structure in which the minor phase (amorphous polyester) is dispersed as domains in the major (EPDM) continuous matrix phase. Differential calorimetry studies confi rmed that both systems were immiscible and exhibits two glass transitions. The melting peak area of EPDM in the blends decreased as the amount of the other component increased. The values of stress at strain of 100% were improved upon the increasing content of PETG in EPDM system, while only slight decrease of this value was observed. Moreover, the strong improvement of hardness and thermo-oxidative stability along with an increasing content of amorphous polyester phase was reported.
Źródło:
Polish Journal of Chemical Technology; 2018, 20, 2; 8-14
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System for the disinfection of cutting fluids using a pulsed electric field
System do dezynfekcji cieczy obróbkowych z wykorzystaniem pulsacyjnego pola elektrycznego
Autorzy:
Umiński, W.
Powiązania:
https://bibliotekanauki.pl/articles/257613.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
contamination
cutting fluid
microorganism cell
pulsed electric field
PEF
electroporation
ciecz obróbkowa
skażenie
komórka mikroorganizmu
pulsacyjne pole elektryczne
elektroporacja
Opis:
During applying cutting fluids (coolants), which are used in the surface treatment of metals, different microorganisms develop. The effects of microbial growth in the cooling system are the following: the shortened life of coolants, increased operating costs, downtime connected with the replacement of coolant, and the exposure of workers to the harmful impact of infected oil mist on skin, eyes, and upper respiratory tract. The paper presents the possibility of an innovative application of a pulsed electric field method to disinfect cutting fluids. The contaminated coolant is subjected to a pulsed electric field with the result that there is a rapid destruction of living microorganisms therein, and their spores. Furthermore, the article demonstrates a laboratory system equipped with a high voltage generator and a control system enabling, inter alia, to change the parameters of the pulsed electric field as well as the laboratory model of the disinfection cell with variable spacing of the electrodes. A research stand made according to the predefined assumptions is also shown. The research stand is intended for testing the effectiveness of reducing the degree of biological contamination of the coolant as a function of the parameters of pulsed electric field. The obtained results are related to the results of a research task of a strategic programme entitled: „Support systems of ecological exploitation of industrial oils and technological liquids”. Obtaining promising test results will be a stage leading to the development of a system for the disinfection of cutting fluids on a technical scale.
W obróbce powierzchniowej metali stosuje się ciecze obróbkowe (chłodziwa), w których, w trakcie ich użytkowania, rozwijają się drobnoustroje. Efektami rozwoju mikroorganizmów w układzie chłodzenia są: skrócenie żywotności chłodziw, zwiększenie kosztów eksploatacji, przestoje produkcyjne związanymi z wymianą chłodziwa oraz narażenie pracowników na szkodliwe dla zdrowia oddziaływanie zarażonej mgły olejowej na skórę, wzrok czy górne drogi oddechowe. W artykule przedstawiono możliwość innowacyjnego zastosowania metody pulsacyjnego pola elektrycznego do dezynfekcji cieczy obróbkowych. Skażone chłodziwo poddawane jest działaniu pulsacyjnego pola elektrycznego w efekcie czego następuje szybkie zniszczenie żyjących w nim mikroorganizmów, a także ich zarodników. Przedstawiono laboratoryjny system wyposażony w generator wysokiego napięcia i układ sterowania umożliwiający między innymi zmianę parametrów impulsowego pola elektrycznego oraz laboratoryjny model celi dezynfekcji o zmiennej odległości elektrod. Przedstawiono stanowisko badawcze wykonane według przyjętych założeń. Wykonane stanowisko badawcze umożliwi przeprowadzenie badań skuteczności zmniejszania stopnia skażenia biologicznego chłodziwa w funkcji parametrów pulsacyjnego pola elektrycznego oraz odniesienie otrzymanych rezultatów do wyników prac uzyskanych w zadaniu badawczym Programu Strategicznego pt.: „Systemy wspomagania proekologicznej eksploatacji olejów przemysłowych i cieczy technologicznych”. Uzyskanie obiecujących wyników badań pozwoli na opracowanie urządzenia do dezynfekcji cieczy obróbkowych w skali technicznej.
Źródło:
Problemy Eksploatacji; 2015, 2; 101-110
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies