Tytuł:
Applications of digital analyzer to characterizing the structures of Ni-Cr-Mo dental casting alloys
Autorzy:
Klimecka-Tatar, D.
Powiązania:
https://bibliotekanauki.pl/articles/114752.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
digital analysis
Ni-Cr-Mo alloy
Ni alloy
analiza cyfrowa
stop Ni-Cr-Mo
stop Ni
stopy dentystyczne
Opis:
This paper presents the possibility of carrying out a structural quantitative analysis of the alloys commonly used in dentistry. On the basis of microscopic observation and digital treatments (LUT and binarization) it was possible to determine the contribution of the phase structure of the Ni-Cr-Mo alloy. The results revealed that differences in the chemical and structural composition of Remanium dental alloys, easily identifiable on the basis of digital image analysis.
Źródło:
Zeszyty Naukowe. Quality. Production. Improvement; 2014, 1 (1); 88-98
2544-2813
Pojawia się w:
Zeszyty Naukowe. Quality. Production. Improvement
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania własności elektrochemicznych stentów wieńcowych
Evaluation of electrochemical properties of coronary stents
Autorzy:
Hyla, A.
Walke, W.
Powiązania:
https://bibliotekanauki.pl/articles/99235.pdf
Data publikacji:
2013
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
stent wieńcowy
stal Cr-Ni-Mo
badanie potencjodynamiczne
EIS
odporność na korozję
coronary stent
Cr-Ni-Mo steel
potentiodynamic test
corrosion resistance
Opis:
W pracy przeprowadzono ocenę właściwości elektrochemicznych stentu wieńcowego wykonanego ze stali austenitycznej Cr-Ni-Mo. W celu zasymulowania warunków występujących w środowisku naczyń krwionośnych człowieka badania przeprowadzono w sztucznym osoczu w temperaturze T = 37 ± 1°C i pH = 7,0 ± 0,2. Badania odporności korozyjnej przeprowadzono w oparciu o rejestrację krzywych polaryzacji anodowej oraz metodę Sterna. Dla oceny zjawisk zachodzących na powierzchni badanego stentu zastosowano również metodę elektrochemicznej spektroskopii impedancyjnej (EIS – Electrochemical Impedance Spectroscopy). Analizie poddano stenty przed i po procesie rozprężenia. W celach porównawczych badania wykonano również dla próbek pobranych ze stali Cr-Ni-Mo w stanie przesyconym o właściwościach mechanicznych odpowiadających stali wykorzystanej do produkcji stentów.
The study includes the evaluation of electrochemical properties of coronary stent made of Cr-Ni-Mo austenitic stainless steel. In order to simulate the conditions found in the human vascular environment studies were carried out in the artificial plasma at a temperature of T = 37 ± 1°C and pH = 7.0 ± 0.2. Corrosion resistance tests were carried out on the basis of registration of the anodic polarization curves and the method of Stern. In order to assess developments on the surface of a stent the method of electrochemical impedance spectroscopy was used. Stents were analyzed before and after expansion. For comparative purposes, tests were also performed to samples of the Cr-Ni-Mo in the supersaturated state of the corresponding mechanical properties of steel used for the production of stents.
Źródło:
Aktualne Problemy Biomechaniki; 2013, 7; 75-80
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie własności fizykochemicznych bezcementowych panewek stawu biodrowego
Electrochemical study of uncemented hip endoprosthesis cups
Autorzy:
Kajzer, W.
Kajzer, A.
Grzeszczuk, O.
Semenowicz, J.
Mroczka, A.
Powiązania:
https://bibliotekanauki.pl/articles/284760.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stal Cr-Ni-Mo
panewka stawu biodrowego
odporność korozyjna
stainless steel
hip endoprosthesis
corrosion resistance
Opis:
Celem prowadzonych badań było porównanie własności panewki nowej oraz po alloplastyce rewizyjnej przebywającej w organizmie człowieka przez 68 miesięcy. W ramach badań przeprowadzono analizę składu chemicznego, własności mechanicznych oraz fizykochemicznych. Własności te analizowano na podstawie badań z wykorzystaniem optycznej spektrometrii emisyjnej ze wzbudzeniem jarzeniowym, pomiarów twardości oraz badań potencjodynamicznych odporności na korozję wżerową i elektrochemicznej spektroskopii impedancyjnej EIS. Badanie elektrochemiczne przeprowadzono w roztworze Ringera. Dodatkowo przeprowadzono analizę makroskopową powierzchni. Na podstawie przeprowadzonych badań stwierdzono, że badane panewki zostały wytworzone ze stali Cr-Ni-Mo spełniającej zalecenia normy ISO 5832-9. Wyniki pomiarów twardości ujawniły obszary o zróżnicowanym umocnieniu biomateriału panewki. Uzyskane parametry odporności korozyjnej dla panewki po implantacji były porównywalne do wartości uzyskanych dla panewki w stanie wyjściowym. Dodatkowo przeprowadzone badania EIS określiły charakter warstwy tlenkowej występującej na powierzchni implantu po usunięciu z organizmu. Wykazały one występowanie warstwy podwójnej stanowiące dobre zabezpieczenie biomateriału metalowego przed rozwojem niekorzystnych zjawisk korozyjnych. Natomiast przeprowadzone obserwacje makroskopowe ujawniły występowanie warstwy hydroksyapatytu na powierzchni panewki po 68-miesięcznym przebywaniu w organizmie. Podsumowując można stwierdzić, że przyczyną alloplastyki rewizyjnej był brak osteointegracji powierzchni zewnętrznej implantu spowodowany nierównomiernym przyleganiem implantu do powierzchni kości. Nie zaobserwowano jednak zmniejszenia odporności korozyjnej panewki po implantacji, co wskazuje na jej biokompatybilność w środowisku tkankowym.
The aim of the research was to compare the properties of the new cup and the cup after alloplastic revision surgery which has been staying in the human body for 68 months. In the studies chemical composition, mechanical and physicochemical properties were analyzed. The properties were analyzed on the basis of studies of glow discharge atomic emission, measurements of hardness and potentiodynamic studies of resistance to pitting corrosion and electrochemical impedance spectroscopy (EIS). The electrochemical research was conducted in Ringer’s solution. Additionally, analysis of the macroscopic surface was conducted. The results revealed that the cups were produced from high nitrogen stainless steel which chemical composition and mechanical properties met the requirements of the ISO 5832-9 standards. The results of hardness revealed areas with varied strengthening of the cup’s biomaterial. Parameters of the corrosion resistance for the cup after implantation were comparable to the values obtained for the cup in the initial state. Additionally, EIS study determined the nature of the oxide layer on the surface of the implant removed from the body. The results showed the existence of a double layer forming good protection of the metal biomaterial against corrosion. The performed macroscopic observation revealed the presence of hydroxyapatite on the surface of the cup after the 68 months in the body. We conclude that the reason for revision arthroplasty was the lack of osteointegration of the outer surface of the implant caused by non- -uniform adhesion of the implant to the bone surface. However, no reduction in corrosion resistance of the cup after implantation was observed which indicates its biocompatibility in the tissue environment.
Źródło:
Engineering of Biomaterials; 2015, 18, 132; 9-16
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bioaccumulation of arsenic, chrome, manganese and nickel in the gills of sea trout (Salmo trutta m. trutta L.) from the southern Baltic Sea (Central Pomeranian Region)
Bioakumulacja arsenu, chromu, manganu i niklu w skrzelach troci wędrownej (Salmo trutta m. trutta L.) z południowej części Morza Bałtyckiego (Region Pomorza Środkowego)
Autorzy:
Tkachenko, H.
Kurhaluk, N.
Kasiyan, O.
Kaminski, P.
Powiązania:
https://bibliotekanauki.pl/articles/2053034.pdf
Data publikacji:
2019
Wydawca:
Akademia Pomorska w Słupsku
Tematy:
(Salmo trutta m. trutta L.)
gills
Baltic Sea
arsenic (As)
chrome (Cr)
manganese (Mn)
nickel (Ni)
Opis:
This study aimed to assess the concentrations of arsenic (As), chrome (Cr), manganese (Mn), and nickel (Ni) in the gills of the sea trout (Salmo trutta m. trutta L.) collected in the Baltic Sea (northern region of Poland). The results were then compared to permissible limits to detect whether the metal contamination levels in sea trout from the Baltic sea exceed the values of limits admissible. Frequently consumed sea trout (25 samples) were purchased from local fisherman in January-February 2014, from Ustka (54°34'43''N 16°52'09''E), Pomeranian voivodship, Poland. The element contents in the gills were analyzed using an inductively coupled plasma mass spectrometry (ICP-MS) technique. Metal contents in fish samples were found 0.00313- 0.02069 mg∙kg-1 for As (the mean value was 0.01294±0.0009 mg∙kg-1), 0.0118-0.02161 mg∙kg-1 for Cr (0.01449±0.0003 mg∙kg-1), 0.01895-0.14216 mg∙kg-1 for Mn (0.04137±0.0046 mg∙kg-1), 0.00664-0.01528 mg∙kg-1 for Ni (0.00811±0.00034 mg∙kg-1). According to these data, the ranking order of the mean concentration of the heavy metals in fish gills was Mn (0.04137 mg∙kg-1) ˃ As (0.01294 mg∙kg-1) ˃ Cr (0.01449 mg∙kg-1) ˃ Ni (0.00811 mg∙kg-1). The mean concentration of arsenic in gill samples (0.01294±0.0009 mg∙kg-1) was much below the permissible limit of USFDA (1993b) and FAO/WHO (1976). The mean Cr content in the gill of sea trout samples was well within the toxic limit of USFDA (1993a). The samples had lower Cr concentration as compared to the limits of 0.200 set by FSANZ (2002) and 0.100 by EUROPA (2004). Our study reported that the accumulation of Mn was exceeding the maximum permissible limit (by 8.27-16.55-fold) according to WHO/EPA standard (0.0025-0.005 mg∙kg-1) (FAO/WHO 1976). The proposed limit of Ni concentrations in marine fish species as recorded by FAO (1983) is about 10 μg/g and 0.5-0.6 μg/g according to WHO Guidelines for drinking water quality (1985). In general, it can be seen that the concentrations of Ni found in gills of the sea trout in this study are still considered as those of uncontaminated fish. In conclusion, the assessment of element contents in the organs of the sea trout appears to be a useful biomarker to evaluate the toxic effects of heavy metal pollution as well as for human consumption.
Źródło:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline; 2019, 23; 65-80
1643-0115
Pojawia się w:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cast steels for creep-resistant parts used in heat treatment plants
Autorzy:
Drotlew, A.
Garbiak, M.
Piekarski, B.
Powiązania:
https://bibliotekanauki.pl/articles/380318.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
innowacyjne technologie odlewnicze
innowacyjne materiały odlewnicze
staliwo austenityczne Ni-Cr
obróbka cieplna
innovative foundry technologies
innovative foundry materials
cast Ni-Cr austenitic steel
castings for heat treatment plants
Opis:
Creep-resistant parts of heat treatment furnaces are in most cases made from high-alloyed chromium-nickel and nickel-chromium iron alloys, both cast and wrought. This paper presents the types of casting alloys used for this particular purpose, since the majority of furnace components are made by the casting process. Standards were cited which give symbols of alloy grades used in technical specifications by the domestic industry. It has been indicated that castings made currently are based on a wider spectrum of the creep-resistant alloy grades than the number of alloys covered by the standards. Alloy grades recommended by the technical literature for individual parts of the furnace equipment were given. The recommendations reflect both the type of the technological process used and the technical tasks performed by individual parts of the furnace equipment. Comments were also made on the role of individual alloying elements in shaping the performance properties of castings.
Źródło:
Archives of Foundry Engineering; 2012, 12, 4; 31-38
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Contents of Copper, Nickel and Chromium in the Sediments of Rainwater Reservoirs Situated Along the National Road No. 4
Zawartość miedzi, niklu i chromu w osadach zbiorników wód deszczowych usytuowanych wzdłuż drogi krajowej nr 4
Autorzy:
Niemiec, M.
Wiśniowska-Kielian, B.
Arasimowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/388782.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
zbiorniki wód deszczowych
osady
zawartość metali
Cu
Ni
Cr
rainwater reservoirs
sediments
metals content
Opis:
The paper aimed at determining heavy metal pollution level of the sediments collected from reservoirs that retain rainwater, localized along the national road No. 4. The sediments were sampled from 11 reservoirs on three dates: in May 2007, in April 2008 and in June 2008 in the Sulkow, Biskupice, Bodzanow and Suchoraba villages, along the ca 10 km section of this road. The sediments were dried in the open air, dry-mineralized and dissolved in a mixture of nitric and chloric acids (3:2, v/v). The contents of copper, chromium and nickel were assessed in the obtained solutions by means of ICP-AES method. Copper contents in the analyzed sediments ranged from 9.29 to 102 mg kg–1, with an average for all samples 34.94 mg Cu kg–1. Chromium contents in the studied sediments comprised in limits 12.6–58.1 mg Cr kg–1, with an average value of 27.7 mg Cr kg–1. Nickel quantities assessed in sediments from rainwater reservoirs were within the range of 7.57–25.62 mg Ni kg–1, with an average value of 13.71 mg kg–1. Changeability (RSD) of the studied metal contents between individual reservoirs fluctuated from 18 to 58 %. The amounts of analyzed elements in the sediments from reservoirs receiving runoffs from the road were much smaller than assessed in similar sediments from various cities worldwide. The investigated sediments do not pose any hazard in view of pollution with copper, chromium or zinc. A regular diminishing of copper content in the sediments was observed with increasing distance from Krakow agglomeration. The closest reservoir is situated in Sulkow, 7 km from the Krakow boundaries, near the boundaries of the Wieliczka town. On the other hand, the reservoir in Suchoraba village is about 17 km far from Krakow. Along this stretch copper content in sediment taken from reservoirs that retain rain water diminished several times, what points at a considerable effect of pollution coming from urban centre on this metal level in the sediments. No such dependence was observed for nickel or chromium.
Celem pracy było określenie poziomu zanieczyszczenia metalami ciężkimi osadów pobranych ze zbiorników zlokalizowanych wzdłuż drogi krajowej nr 4 przyjmujących wody deszczowe. Osady pobrano z 11 zbiorników w trzech terminach: maj 2007 r., kwiecień 2008 r. i czerwiec 2008 r. z miejscowości: Sułków, Biskupice, Bodzanów i Suchoraba na odcinku ok. 10 km. Osady wysuszono na powietrzu i zmineralizowano na sucho i roztworzono w mieszaninie kwasów azotowego(V) i chlorowego(VII) w stosunku objętościowym 3:2. W uzyskanych roztworach oznaczono ogólną zawartość miedzi, chromu oraz niklu metodą ICP-AES. Zawartość miedzi w badanych osadach mieściła się w granicach od 9,29 do 102 mg kg-1. Średnia dla wszystkich próbek wynosiła 34,94 mg kg-1. Stężenie chromu w badanych osadach wahało się w granicach 12,6-58,1 mg Cr kg-1, a średnio wynosiło 27,7 mg kg-1. Ilości niklu oznaczone w osadach ze zbiorników wód opadowych mieściły się w zakresie 7,57-25,62 mg Ni kg-1. Średnia zawartość tego pierwiastka wynosiła 13,71 mg kg-1. Zmienność (RSD) stężeń badanych metali pomiędzy poszczególnymi zbiornikami wahało się w granicach 18-58 %. Ilości badanych pierwiastków w osadach ze zbiorników przyjmujących spływy z drogi były znacznie mniejsze niż stwierdzane w podobnych osadach w innych miastach na świecie. Badane osady nie stanowią zagrożenia ze względu na zawartość miedzi, niklu i chromu. Zaobserwowano regularne zmniejszanie zawartości miedzi w miarę oddalania się od aglomeracji krakowskiej. Zbiornik usytuowany najbliżej Krakowa w Sułkowie oddalony jest o ok. 7 km od rogatek Krakowa i znajduje się przy granicy z miastem Wieliczka, natomiast zbiornik w Suchorabie jest oddalony o ok. 17 km od Krakowa. Na tym odcinku zawartość miedzi w osadach ze zbiorników wód deszczowych zmniejszyła się kilkakrotnie, co wskazuje na znaczny wpływ zanieczyszczeń napływających z ośrodka miejskiego na poziom tego metalu w osadach. W przypadku niklu i chromu nie zaobserwowano takiej zależności.
Źródło:
Ecological Chemistry and Engineering. A; 2012, 19, 1-2; 113-122
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion Behavior of Hastelloy® C-2000® Ni-Cr-Mo-Fe Alloys in the Entrained-Flow Coal Gasification Syngas Plants
Autorzy:
Lee, Sungkyu
Kim, Min-Jung
Choi, Nuri
Hwang, Sang Yeon
Chung, Seok-Woo
Lee, Seung-Kong
Yun, Yongseung
Powiązania:
https://bibliotekanauki.pl/articles/352403.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mixed oxidant corrosion
Hastelloy® C-2000® Ni-Cr-Mo-Fe alloy
coal gasification
high temperature halogencorrosion
hydrated chlorides
Opis:
A mechanistic exposure experiment was performed on the commercially available and welded Ni-Cr-Mo-Fe alloy samples used in the piping materials of the coal gasification pilot plant. Thermodynamic Ellingham-Pourbaix stability diagrams were constructed to provide insight into the mechanism of the observed corrosion behavior. The thermodynamic inference on the corrosion mechanism was supplemented with the morphological, compositional and microstructural analyses of the exposed samples using scanning electron microscopy, X-ray diffraction and energy-dispersive X-ray spectroscopy analyses. X-ray diffraction result revealed stable corrosion products of NiO, MoNi4 and Cr4.6 MoNi2.1 after accumulated total exposure duration of 139 h to the corrosive atmosphere. Scanning electron microscopy and energy-dispersive X-ray spectroscopy positively identified formation of rather continuous and adherent pre-oxidation corrosion products although extensively peeled-off oxides were finally observed as corrosion scales on the post-exposure alloy samples, which were attributed to the chlorination/oxidation into thin (spalled) oxides.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 2; 869-878
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
D-gun Sprayed Fe-Al Single Particle Solidification
Krystalizacja pojedynczej cząstki Fe-Al naniesionej metodą detonacyjną
Autorzy:
Wołczyński, W.
Senderowski, C.
Morgiel, J.
Garzeł, G.
Powiązania:
https://bibliotekanauki.pl/articles/352240.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Fe-Al coating
Ni-20Cr interlayer
rapid solidification
D-gun spraying
boron localization
competitive growth of phases
powłoki FeAl
międzywarstwy Ni-20Cr
szybkie krzepnięcie
metoda detonacyjna
lokalizacja boru
proces wzrostu faz
Opis:
Some Fe-Al particles less than 50 μm in diameter were deposited onto the steel substrate by means of the D-gun spraying. A solidification mechanism of an individual particle is described. The particle subjected to the description contained nominally 63 at.% Al. The description was preceded by the TEM / SAED analysis of both the Fe-Al coating and Ni-20Cr interlayer. The whole number of the analyzed particles was partially melted during the deposition. The solidification products like: amorphous phase sub-layer, oscillatory sub-layer which contains two types lamellae distributed alternately and typically non-equilibrium phase sub-layer were revealed. In the micro scale, solidification was considered as a process which occurred in two directions: towards the substrate and towards the non-melted particle part. Both solidification processes underwent the positive thermal gradients. The boron addition was localized within the eutectic precipitates pushed and then rejected by the solid/liquid interface of the solidifying non-equilibrium phase. The proposed model is a general one and therefore can be applied to other systems ;description.
Cząstki proszku Fe-Al niniejsze niż 50 μm w średnicy zostały osadzone detonacyjnie na podłożu stalowym. Opisuje się mechanizm krystalizacji pojedynczej cząstki. Cząstki poddane opisowi zawierały nominalnie 63 aL% Al. Opis poprzedzono badaniami struktury metodą TEM / SAED dotyczącymi zarówno powłoki Fe-Al jak i między warstwy Ni-20Cr. Wszystkie analizowane cząstki były częściowo nadtopione podczas osadzania. Zidentyfikowano produkty krystalizacji takie jak: podwarstwę amorficzną, podwarstwę oscylacyjną zawierającą periodycznie ułożone pły tki dwu faz oraz podwarstwę zawierającą fazę typowo nierównowagową. W mikroskali proces wzrostu faz jest analizowany jako zachodzący w dwu kierunkach: w stronę podłoża i w stronę niestopionej części cząstki. Obydwa procesy wzrostu zachodziły w obecności dodatniego gradientu temperatury. Bor dodany do powłoki został zlokalizowany w eutektyce odepchniętej przez front krystalizacji fazy typowo nierównowagowej. Proponowany model ma charakter ogólny i może być zastosowany do opisu innych systemów.
Źródło:
Archives of Metallurgy and Materials; 2014, 59, 1; 211-220
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of γ′+γ / γ Phase Boundary in Ni-Al-Cr System Using DTA Thermal Analysis
Autorzy:
Maciąg, T.
Rzyman, K.
Powiązania:
https://bibliotekanauki.pl/articles/354947.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DTA thermal analysis
order-disorder transition
Ni3Al
Ni-Al-Cr
Opis:
Mechanical properties at elevated temperature, in modern alloys based on intermetallic phase Ni3Al are connected with phase composition, especially with proportion of ordered phase γ′ (L12) and disordered phase γ (A1). In this paper, analysis of one key systems for mentioned alloys - Ni-Al-Cr, is presented. A series of alloys with chemical composition originated from Ni-rich part of Ni-Al-Cr system was prepared. DTA thermal analysis was performed on all samples. Based on shape of obtained curves, characteristic for continuous order-disorder transition, places of course of phase boundaries γ′+γ / γ were determined. Moreover, temperature of melting and freezing of alloys were obtained. Results of DTA analysis concerning phase boundary γ′+γ / γ indicated agreement with results obtained by authors using calorimetric solution method.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 1; 237-240
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detonation deposited Fe-Al coatings. Part II: Transmission electron microscopy of interlayers and Fe-Al intermetallic coating detonation sprayed onto the 045 steel substrate
Detonacyjne osadzanie warstw Fe-Al. Część II: Transmisyjna mikroskopia elektronowa warstw pośrednich oraz powłoki faz typu Fe-Al natryskiwanych detonacyjnie na podłoże stali 045
Autorzy:
Pawłowski, A.
Senderowski, C.
Wołczyński, W.
Morgiel, J.
Major, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/354124.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
natryskiwanie detonacyjne
powłoki międzymetaliczne
D-gun spraying
Fe-Al intermetallic coatings
Ni(Al) and Cr(Al) interlayers
Opis:
The microstructure of detonation gaseous sprayed (DGS) transition layers of Ni(Al), Ni(Cr) and subsequent coating of Fe-Al intermetallic phases deposited on the 045 steel were studied in the paper using transmission electron microscopy. In order to identify phases in the particular interlayers the selected area electron diffraction (SAED) and an energy dispersive X-ray microanalysis (EDX) were applied. It was found that the Ni(Al) interlayer contained basically pure nickel with a small fraction of NiAl phase. The Al based amorphous phase was also observed its area in the form of bands. The Ni(Cr) interlayer basically contained Ni-rich small grains. Pure chromium in the Ni matrix appeared in the vicinity of Fe-Al coating in the shape of bow-like bands, parallel to the coating. The boundary between the Ni(Cr) layer and the Fe-Al coating revealed abrupt decrease of the Ni content in the coating at simultaneous rapid increase of the Fe amount. Improper Al/Cr ratio within the Ni matrix seems to be responsible for the formation of Al-oxides and the bands of almost pure Cr and Ni(Cr) layers and resulting decrease of interlayer adherence.
W pracy analizowano mikrostrukturę złożonej budowy wielowarstwy składającej się z podłoża ze stali węglowej 045 oraz osadzonych detonacyjnie (DGS) na niej warstw pośrednich Ni(Al) i Ni(Cr) oraz powłoki faz międzymetalicznych typu Fe-Al. W celu identyfikacji faz powłoki i warstw pośrednich zastosowano techniki badawcze: dyfrakcji elektronowej (SAED) oraz analizy składu chemicznego faz (EDX) w transmisyjnym mikroskopie elektronowym. Stwierdzono, że warstwa Ni(Al) zawiera przede wszystkim prawie czysty nikiel z małym udziałem fazy NiAl. Oprócz tego w obszarze ziaren Ni występowała faza amorficzna w postaci pasm oparta na Al i O. Obecność niewielkich rozmiarów ziaren bogatych w nikiel stwierdzono również w warstwie Ni(Cr), wewnątrz których znajdowały się pasma czystego chromu. Granica pomiędzy Ni(Cr) oraz powłoką Fe-Al wykazywała gwałtowny spadek zawartości niklu przy jednoczesnym silnym wzroście żelaza. Obecność tlenków aluminium oraz pasm bogatych w chrom wynikała z niewłaściwych proporcji Al/Cr podczas przygotowania wielowarstw i wpływała negatywnie na ilość mikropęknięć i porów oraz wynikającą z tego adhezję pomiędzy poszczególnymi warstwami.
Źródło:
Archives of Metallurgy and Materials; 2011, 56, 1; 71-79
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detonation deposited Fe-Al coatings Part III: Morphology of the Ni(Cr) and Ni(Al) interlayers and Fe-Al coating sprayed onto the 045 steel substrate
Powłoki Fe-Al osadzane detonacyjnie. Część III: budowa warstw pośrednich Ni(Cr) I Ni(Al) oraz powłoki Fe-Al na podłożu stali węglowej osadzanych detonacyjnie
Autorzy:
Pawłowski, A.
Senderowski, C.
Bojar, Z.
Bonarski, J.
Major, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/351088.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
powłoki międzymetaliczne
warstwy pośrednie Ni(Cr) i Ni(Al)
G-dun spraying
Fe-Al intermetallic coatings
Ni(Al) and Ni(Cr) interlayers
Opis:
The morphology of interlayars and the coating of Fe-Al phase detonation sprayed (DGS) on the substrate of 045 steel was analysed in the work. The Ni(Al) layer, first from the substrate side consisted of Ni with inclusions of Al oxide. The second deposited layer was Ni(Cr), which contained lamellas of Cr in the Ni matrix. The phases present in the transition layers and in the coating were identified with SEM, and EDX methods (linear and point changes of chemical composition). The identification was confirmed with the X-ray technique and TEM microstructure analysis. It was established that Al oxides and AlNiO phases appeared in the DGS process after partial melting and oxidation of Al particles, while in the not melted part of grains small grain morphology was observed. Using the X-ray method, the FeAl2O4, Fe3Al and FeAl phases were identified in the coating, the Cr and Cr2Ni3 phase in the Ni(Cr) interlayer as well as pure nickel and the NiAl phase in the Ni(Al) interlayer. The occurrence of brittle phases of Al oxide and AlNiO phases near the boundaries of layers might result in the increase of tendency to delamination. Hence the reduction of the Al content seems advantageous from the point of view of mechanical properties of the joint.
W pracy poddano analizie metodą skaningowej - SEM i transmisyjnej- TEM mikroskopii elektronowej, budowę warstw pośrednich i powłokę faz typu Fe-Al natryskiwanych detonacyjnie (DGS) na podłoże stali 045. Warstwa Ni(Al) pierwsza od podłoża składa się z niklu z wtrąceniami Al i tlenku glinu. Na niej osadzona jest warstwa druga Ni(Cr) składającą się z warstewek chromu w osnowie niklu. Metodami EDX, liniowej zmiany składu oraz punktowej analizy zidentyfikowano fazy w warstwach pośrednich i powłoce. Tą identyfikację potwierdzono techniką X-ray oraz analizą mikrostruktury TEM. Ustalono, że tlenki oraz AlNiO fazy powstały w procesie DGS po nadtopieniu i utlenieniu cząstek Al, zaś w nie nadtopionej części ziaren zaobserwowano drobnoziarnistą budowę. W powłoce zidentyfikowano metodą X-ray fazy: FeAl2O4, Fe3Al oraz FeAl, w warstwie pośredniej Ni(Cr) - chrom i fazę Cr2Ni3w osnowie niklu, zaś w warstwie Ni(Al) czysty nikiel i fazę NiAl. Występowanie faz tlenku glinu i faz AlNiO w pobliżu granic warstw pośrednich powodować może zwiększenie tendencji do delaminacji. Korzystnym byłoby zatem obniżenie ilości aluminium.
Źródło:
Archives of Metallurgy and Materials; 2011, 56, 2; 262-269
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
DSC Analysis of Order–Disorder Transition in Ni3Al Based Alloys From Ni-Al-Cr System
Analiza DSC przemian typu porządek-nieporządek w stopach na osnowie Ni3Al z układu Ni-Al-Cr
Autorzy:
Maciąg, T.
Rzyman, K.
Przeliorz, R.
Powiązania:
https://bibliotekanauki.pl/articles/356471.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ni-Al-Cr system
intermetallic phase Ni3Al
order-disorder
DSC analysis
system Ni-Al-Cr
faza międzymetaliczna Ni3Al
faza nieuporządkowana
analiza DSC
Opis:
Ni-Al-Cr system is significant for industrial alloys based on intermetallic phase Ni3Al, that crystallizes in crystal lattice L12. It is indicated as γ′, contrary to disordered phase γ which occurs with addition of chromium. DSC analysis was performed on alloys of chemical composition from Ni75Al25÷Ni75Cr25 range of Ni-rich part of Ni-Al-Cr system. In addition, few measurements were conducted using DTA method. Based on curves registered, it was possible to identify characteristic temperature during heating and cooling of the sample. It corresponds to existence of phase boundary γ′+γ / γ in examined alloys. Results of thermal analysis were compared with results obtained with other method performed by authors which is solution calorimetric method.
Układ Ni-Al-Cr jest ważnym układem dla przemysłowych stopów na osnowie fazy międzymetalicznej Ni3Al, która krystalizuje w uporządkowanej sieci L12. Oznacza się ją jako γ′ w odróżnieniu od fazy nieuporządkowanej γ, która pojawia się wraz z dodatkiem stopowym chromu. Wykonano serię stopów, których skład chemiczny leży na linii Ni75Al25÷Ni75Cr25 w bogatej w nikiel części układu Ni-Al-Cr i poddano je analizie DSC. Dodatkowo wykonano kilka pomiarów metodą DTA. Na podstawie zarejestrowanych krzywych udało się zidentyfikować charakterystyczne temperatury podczas nagrzewania i studzenia próbki. Odpowiadają one miejscom występowania granicy międzyfazowej γ′+γ / γ w stopach. Wyniki analiz termicznych zestawiono z wynikami innej metody zastosowanej przez autorów tj. kalorymetrycznej metody typu rozpuszczania.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3A; 1871-1876
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
DTA Thermal Analysis of Alloys from Nickel-Rich Part of Ni-Al-Cr System
Autorzy:
Maciąg, T.
Powiązania:
https://bibliotekanauki.pl/articles/351762.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ni-Al-Cr system
order-disorder
DTA analysis
Opis:
Thermal analysis allows for determination of temperature specific for the beginning and the end of phase transitions occurring in studied samples. In this paper results obtained from DTA (Differential Thermal Analysis) of alloys of chemical composition referring to nickel-rich part of Ni-Al-Cr system, specifically from section Ni75Al25÷Ni65Cr35 are presented. Those alloys are based on intermetallic phase Ni3 Al. Referring to measurements obtained during heating and cooling, characteristic peaks related to occurrence of phase transition of order-disorder type were noted as well as melting and solidification temperature of alloys was determined. Results of thermal analysis DTA of studied range were compared with results obtained for section Ni75Al25÷Ni75Cr25 and Ni75Al25÷Ni87Cr13, additionally results of measurements performed on high-temperature solution calorimeter were collated. Both methods presented good compatibility.
Źródło:
Archives of Metallurgy and Materials; 2018, 63, 2; 981-986
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of adding furnace ash from bituminous coal combustion to soil on phytoavailability of selected metals
Wpływ dodatku popiołu paleniskowego z węgla kamiennego do gleby na fitoprzyswajalność wybranych metali
Autorzy:
Antonkiewicz, J.
Jasiewicz, C.
Kępka, W.
Kowalewska, A.
Pełka, R.
Losak, T.
Hlusek, J.
Powiązania:
https://bibliotekanauki.pl/articles/296897.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
ash
Cr
Mn
Fe
Ni
Cu
Al
maize
tolerance index
metal translocation factor
metal content
metal uptake
popiół
kukurydza
indeks tolerancji plonu
wskaźnik translokacji metali
zawartość metali
pobranie metali
Opis:
The research on the effect of furnace ash from bituminous coal combustion on the uptake of Cr, Cu, Ni, Fe, Mn, Al by maize (Zea mays L.) was conducted under conditions of a three-year pot experiment. The arable soil in the pot experiment was amended with furnace ash in the amount of 23.33 g·pot‒1 (corresponding to 20 t·ha‒1) and with increasing doses of cadmium (3÷15 mg·kg‒1 soil DM). Application of ash and cadmium in the amount of 3÷5 mg·kg‒1 DM to the soil had a significant effect on the increase in the yield of above-ground parts and roots of maize. Application of subsequent doses of cadmium (7.5÷15 mg·kg‒1) caused a considerable reduction in the yield of the tested plant. The research shows that the applied furnace ash reduced the depression in yielding of maize. Introduction of furnace ash to cadmium-contaminated soil caused an increase in the content of Cr, Fe, Ni, Cu and Al in maize biomass and a decrease in the content of Mn in maize. Among the studied metals, Mn was translocated from roots to above-ground parts the most efficiently, and Al - the least efficiently, evidence of which are the highest values of the translocation factor for Mn, and the lowest values for Al. The research showed that ash introduced to cadmium-contaminated soil did not immobilize the above-mentioned metals, and thereby did not reduce the phytoavailability. In general, contamination of the soil with cadmium and introduction of ash stimulated uptake of the metals by maize. We observed that roots took up more Cr, Fe, Ni and Al, whereas above-ground parts of maize took up more Mn and Cu. The lowest uptake of the studied metals by maize was observed in the treatment where only furnace ash was applied.
Badania nad wpływem popiołu paleniskowego z węgla kamiennego na pobieranie Cr, Cu, Ni, Fe, Mn, Al przez kukurydzę (Zea mays L.) przeprowadzono w warunkach trzyletniego doświadczenia wazonowego. W doświadczeniu wazonowym zastosowano do gleby uprawnej popiół paleniskowy, w ilości 23,33 g·wazon‒1, odpowiadającej 20 t·ha‒1, oraz wzrastające dawki kadmu, w ilości 3÷15 mg·kg‒1 s.m. gleby. Zastosowanie popiołu oraz kadmu w ilości 3÷5 mg·kg‒1 s.m. do gleby wpłynęło istotnie na zwiększenie plonu części nadziemnych i korzeni kukurydzy. Natomiast zaaplikowanie kolejnych dawek kadmu (7,5÷15 mg·kg‒1) spowodowało istotne obniżenie plonu testowanej rośliny. Z badań wynika, że zaaplikowany popiół paleniskowy zmniejszył depresję plonowania kukurydzy. Wprowadzenie popiołu paleniskowego do gleby zanieczyszczonej kadmem wpłynęło na zwiększenie zawartości Cr, Fe, Ni, Cu i Al w biomasie kukurydzy, natomiast wpłynęło na zmniejszenie zawartości Mn w kukurydzy. Spośród badanych metali najłatwiej był przemieszczany z korzeni do części nadziemnych Mn, a najsłabiej Al, o czym świadczą największe wartości współczynnika translokacji dla Mn, a najmniejsze wartości dla Al. Z badań wynika, że popiół wprowadzony do gleby zanieczyszczonej kadmem nie wpłynął na immobilizację wyżej wymienionych metali, a tym samym nie ograniczył fitoprzyswajalności. Generalnie zanieczyszczenie gleby kadmem i wprowadzenie popiołu stymulowało pobieranie metali przez kukurydzę. Stwierdzono większe pobranie Cr, Fe, Ni i Al przez korzenie, natomiast Mn i Cu przez części nadziemne kukurydzy. Najmniejsze pobranie badanych metali przez kukurydzę zarejestrowano w obiekcie, w którym zastosowano wyłącznie popiół paleniskowy.
Źródło:
Inżynieria i Ochrona Środowiska; 2015, 18, 4; 405-422
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Laser Surface Melting on Microstructure of Cold Sprayed Ni20Cr Coatings
Autorzy:
Soboń, D.
Powiązania:
https://bibliotekanauki.pl/articles/2049393.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cold spraying
Ni20Cr coating
laser modification
mechanical properties
Opis:
In this study, Ni20Cr coatings were obtained by cold spraying on an aluminum alloy 7075 substrate. The obtained coatings were characterized by a uniform microstructure and low porosity. The sprayed coating has the same phase composition as the powder used. Next, the cold sprayed coatings were heat treated using a TRUMPF TLF 6000 TURBO (4 kW) CO2 laser. The laser surface melting of the coatings resulted in the formation of a columnar structure and an improvement in their mechanical properties. The Ni20Cr cold sprayed coatings after additional laser melting showed lower porosity and an increase in microhardness and Young`s modulus.
Źródło:
Archives of Metallurgy and Materials; 2021, 66, 3; 853-860
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies