Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Magnetic field" wg kryterium: Temat


Tytuł:
A method of the magnetic field formation in cyclotron DC-72
Autorzy:
Gulbekian, G.
Ivanenko, I.
Filatov, O.
Franko, J.
Kukhtin, V.
Lamzin, E.
Samsonov, E.
Semchenkov, A.
Semchenkova, O.
Sytchevsky, S. E.
Dmitrev, S. N.
Powiązania:
https://bibliotekanauki.pl/articles/148354.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
cyclotron
magnetic field measurements
magnetic field simulations
Opis:
A method of the magnetic field formation in the cyclotron DC-72 model (scale 1:5) is described. The cyclotron is planned to be built in Slovakia. The stages in the shimming of the cyclotron sectors and an automatic system designed for magnetic measurements are described. The data on the magnetic field measurements in the median plane of the cyclotron are presented. A brief description of a computer simulation model and an algorithm of fitting the required sector profiles is presented, as well as the data on the computer simulation of magnetic field distributions. The data on the magnetic field measurements and those on the computer simulations are compared and analyzed. Possible reasons of differences between the measured and simulated data are discussed. The results of the above mentioned computer simulations will be used for building a large facility - the cyclotron DC-72.
Źródło:
Nukleonika; 2003, 48, 4; 207-210
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematica implementation of BEM model for magnetic field analysis in parallel conductors with time-harmonic currents
Implementcaja w Mathematice modelu MEB do analizy harmonicznego pola magnetycznego układu równoległych przewodów z prądem sinusoidalnym
Autorzy:
Jabłoński, P.
Powiązania:
https://bibliotekanauki.pl/articles/376039.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
time-harmonic magnetic field
magnetic field
BEM
conductors
Opis:
This paper presents a computational model for time-harmonic magnetic field analysis in a configuration of any number of long parallel conductors carrying currents or exposed to an externally applied transverse magnetic field. The model is based on the Boundary Element Method (BEM) and implemented in Mathematica by effective use of its built-in functions and algorithms. The cross-sections of the conductors can have any shapes, with or without holes. In addition, it is possible to add any number of filamentary currents. The model allows finding magnetic field at a given point, powers transmitted across the boundaries of the wires, and the matrix of self and mutual impedances of the considered set of wires. Examples of its use are presented.
W pracy przedstawiono model obliczeniowy dla pola EM w dowolnym układzie długich równoległych przewodów wiodących prądy sinusoidalne lub poddanych działaniu zewnętrznego poprzecznego pola magnetycznego. Model wykorzystuje metodę elementów brzegowych (MEB) i jest zaimplementowany w Mathematice, co pozwala na efektywne wykorzystanie wielu wbudowanych w nią funkcji i algorytmów. Przewody mogą mieć dowolne przekroje poprzeczne, pełne lub wydrążone. Można także dodać dowolną liczbę przewodów nieskończenie cienkich. Model pozwala na obliczanie pola magnetycznego w dowolnym punkcie, mocy wnikającej do obszarów przewodzących oraz macierzy impedancji własnych i wzajemnych. Zaprezentowano przykłady jego zastosowania.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 69; 65-72
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Static or dynamic low-frequency magnetic field? A review of literature
Statyczne czy zmienne pole magnetyczne niskiej częstotliwości? Przegląd piśmiennictwa
Autorzy:
Głąb, Grzegorz
Dudek, Jolanta
Klimek, Krzysztof
Skalska-Dulińska, Barbara
Urszula Chrabota, Urszula
Chojak-Fijałka, Katarzyna
Ridan, Tomasz
Glodzik, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/1798756.pdf
Data publikacji:
2016
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
low-frequency magnetic field
static magnetic field
magnetic field therapy
pole magnetyczne niskiej częstotliwości
stałe pole magnetyczne
magnetoterapia
Opis:
The therapeutic application of magnetic fi elds has experienced signifi cant growth in recent years. A small number of contraindications, as well as the lack of side effects makes both permanent magnets and alternating magnetic fi elds frequently used in physical therapy practice. In a signifi cant number of clinical studies the effi cacy of this physical factor as both an independent method, as well as supporting treatment programs has been confi rmed. In the last few years, a lot of emphasis is put on the fact that all therapeutic methods should have a scientifi c basis and their usage should meet the evidence based medicine criteria (EBM). Therefore, this work will focus on comparison of the use of permanent magnets and alternating low-frequency magnetic fi eld on the basis of the available literature, including mainly, a randomized double-blind trial. Analysis of the available literature on permanent magnet usage has shown clinical effi cacy in many diseases, however, placebo-controlled studies confi rm mainly the analgesic effect in patients after liposuction surgery, with diabetic neuropathy and with chronic pelvic pain. The use of the alternating low-frequency magnetic fi eld also leaves many questions to which scientists have still not found the answer. Randomized double-blind trial proved its therapeutic effi cacy in patients after knee arthroscopy, fractures and delayed bone unions, knee and cervical spine osteoarthritis as well as in case of leg ulceration. Alternating magnetic fi eld application has a wider therapeutic range in comparison to permanent magnets and its effectiveness is much better documented, both in clinical studies as well as randomized double-blind trials. Cite this article as: Głąb G., Dudek J., Klimek K., Skalska-Dulińska B., Chrabota U., Chojak-Fijałka K., Ridan T., Glodzik J. Static or dynamic low-frequency magnetic field? A review of literature. Med Rehabil 2016; 20(2): 31-35.
Terapeutyczne zastosowanie pól magnetycznych wykazuje w ostatnich latach znaczący rozwój. Niewielka liczba przeciwwskazań, jak również brak działań ubocznych przyczyniają się do częstego stosowania tych zabiegów w praktyce fizykoterapeutycznej. W znacznej liczbie prac klinicznych potwierdzono skuteczność tego czynnika fizykalnego zarówno jako samodzielnej metody, jak i wspomagającej w programach terapeutycznych. W terapii stosuje się zarówno magnesy stałe, jak i zmienne pola magnetyczne. W ostatnich latach kładzie się coraz większy nacisk na to, aby wszelkiego rodzaju metody lecznicze miały podstawy naukowe, a ich zastosowanie spełniało kryteria medycyny opartej na faktach (evidence based medicine). Autorzy niniejszej pracy skupią się zatem na omówieniu zastosowania magnesów stałych i zmiennego pola magnetycznego niskiej częstotliwości na podstawie dostępnej literatury obejmującej randomizowane badania na podwójnie ślepej próbie. Analiza dostępnej literatury dotyczącej stosowania magnesów stałych wykazała ich skuteczność kliniczną w wielu schorzeniach, badania z grupą placebo potwierdziły natomiast działanie głównie przeciwbólowe u pacjentów po zabiegach liposukcji, u osób z neuropatią cukrzycową oraz u pacjentek z przewlekłym bólem miednicznym. Zastosowanie zmiennych pól elektromagnetycznych niskiej częstotliwości również pozostawia wiele pytań, na które jak do tej pory naukowcy nie znaleźli odpowiedzi. W badaniach na podwójnie ślepej próbie udowodniono skuteczność terapeutyczną u pacjentów po artroskopii stawu kolanowego, złamaniach i opóźnionym zrostem kostnym, u osób ze zmianami zwyrodnieniowymi stawów kolanowych i kręgosłupa szyjnego, a także w przypadku owrzodzeń podudzi. Działanie pól zmiennych ma w porównaniu z magnesami stałymi znacznie większy zakres terapeutyczny, a skuteczność ich działania jest o wiele lepiej udokumentowana zarówno w badaniach klinicznych, jak i randomizowanych na podwójnie ślepej próbie.
Źródło:
Medical Rehabilitation; 2016, 20(2); 31-35
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wektorowy gradiometr pola magnetycznego
Magnetic field vector gradiometer
Autorzy:
Wołoszyn, M.
Powiązania:
https://bibliotekanauki.pl/articles/156108.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
gradiometr pola magnetycznego
pole magnetyczne
czujnik magnetyczny
magnetic field gradiometer
magnetic field
magnetic sensor
Opis:
W pracy przedstawiono metodę wyznaczania parametrów wektorowego gradiometru magnetycznego mających istotny wpływ na przybliżony pomiar pochodnych cząstkowych. Wartości pochodnych cząstkowych mierzone są w sposób przybliżony metodą różnicową. Dokładność pomiaru różnicy indukcji magnetycznej zależy od kąta przesunięcia osi czujników magnetycznych, przesunięcia zera i współczynnika skali czujników oraz od odległości między czujnikami. Skuteczność wykrywania obiektów ferromagnetycznych z zastosowaniem wektorowego gradiometru bez informacji o wartościach tych parametrów jest bardzo niska.
Five independent partial derivatives of the magnetic flux density vector are used for detecting ferromagnetic objects by use of vector gradiometers in algorithms of object locating and identifying. This method requires precise measurement of the magnetic flux density gradient (1). A gradiometer built of magnetometers with directional sensitivity characteristics has several parameters, called critical in this paper, that influence the measurement of partial derivatives in a significant way. The gradiometer critical parameters are: angle between the axis of magnetic sensors, offset, accuracy of measurements of separate sensors and the distance between them. The critical parameters values can be determined on a basis of measurements from formulas (4-8). Partial derivatives (1) are determined on a basis of measuring the difference quotient of the magnetic flux density. When choosing the distance sensors, their sensitivity and approximation of partial derivatives by difference quotients should be taken into account.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 12, 12; 1525-1527
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Issues involved in using the direct method for magnetic field strength measurement of electrical steel sheets – review
Problemy pomiaru natężenia pola magnetycznego blach elektrotechnicznych metodą bezpośrednią – przegląd
Autorzy:
Gaworska-Koniarek, D.
Bajorek, J.
Wilczyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/159080.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
pomiar natężenia pola magnetycznego
czujniki pola magnetycznego
metoda bezpośrednia
magnetic field strength measurements
magnetic field sensor
magnetic field measurement
direct method
Opis:
W artykule, na podstawie dokonanego przeglądu literatury, przedstawiono istniejące problemy pomiaru natężenia pola magnetycznego metodą pośrednią i bezpośrednią w blachach elektrotech-nicznych oraz próby ich rozwiązania. Opisano czujniki składowej natężenia pola magnetycznego stosowane najczęściej do pomiaru natężenia pola magnetycznego w blachach elektrotechnicznych.
The paper presents, based on a review of relevant literature, the existing problems of magnetic field strength measurements of electrical steel sheets by means of the indirect and direct methods. It also describes some attempts to solve these problems. The magnetic field strength sensors most widely used for testing electrical steel sheets are also discussed.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 274; 71-82
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of magnetic field on the corrosion of iron as studied by positron annihilation
Autorzy:
Pietrzak, R.
Szatanik, R.
Powiązania:
https://bibliotekanauki.pl/articles/146285.pdf
Data publikacji:
2010
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
corrosion
magnetic field
positron annihilation
Opis:
Lifetime spectra of positron annihilation in iron corroded in a water solution of HCl and in vapour above its surface have been investigated with emphasis on the effect of corrosion time and environment (solution or vapour) as well as of the presence and orientation of the magnetic field on the measured positron annihilation parameters. All the registered positron lifetime spectra consist of two components. For corroded samples, the intensities of the two components as well as the corresponding values of the mean positron lifetime, differ from those for uncorroded material. The corrosion-induced changes in the positron annihilation parameters depend on the corrosion environment (solution or vapour) and on the presence and direction of external magnetic field.
Źródło:
Nukleonika; 2010, 55, 1; 31-34
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of a magnetic field monitoring system for the JAERI AVF cyclotron
Autorzy:
Okumura, S.
Arakawa, K.
Fukuda, M.
Nakamura, Y.
Yokota, W.
Ishimoto, T.
Kurashima, S.
Ishibori, I.
Nara, T.
Agematsu, T.
Nakajima, T.
Powiązania:
https://bibliotekanauki.pl/articles/148733.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
compensation coil
cyclotron
magnetic field
Opis:
We have developed a probe of a nuclear magnetic resonance (NMR) magnetometer for measurement of a fluctuation of an AVF cyclotron field. The stability of the magnetic field of the JAERI AVF cyclotron, measured with the NMR probe, was within 1 × 10-5. A field-measurement accuracy of the order of 1 × 10-6 was achieved using a set of field-compensation coils and optimizing the probe position to obtain enough homogeneity of the magnetic field around the probe for measuring the cyclotron field with a high gradient. To eliminate a major bottleneck in the field measurement inside the cyclotron, the probe was specially produced with the cable shielding against RF noises and proper materials applied.
Źródło:
Nukleonika; 2003, 48,suppl.2; 35-37
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flow patterns generated by a strong magnetic field
Wpływ silnego pola magnetycznego na strukturę przepływu
Autorzy:
Fornalik, E.
Powiązania:
https://bibliotekanauki.pl/articles/279226.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
spoke pattern
thermosyphon
magnetic field
Opis:
The influence of a strong magnetic field on a paramagnetic fluid in a cylindrical enclosure of thermosyphon-like geometry was studied. A variety of spoke patterns was experimentally obtained and recorded. The analysis led to some data about the temperature field and, indirectly, about the flow structure. The results related to the heat transfer rate confirmed the conclusions coming from the flow visualization.
Przedstawione zostały badania dotyczące struktury przepływu w geometrii cylindrycznej typu odwrócony termosyfon (tzn. górna część cylindra była grzana, a dolna chłodzona). Naczynie eksperymentalne napełnione cieczą paramagnetyczną zostało umieszczone w przestrzeni badawczej magnesu nadprzewodzącego, generującego silne pole magnetyczne (maksymalna indukcja magnetyczna 5 Tesli). Badano wpływ pola magnetycznego na strukturę przepływu, dokonano wizualizacji pola temperatury przy pomocy ciekłych kryształów oraz pomiaru temperatury za pomocą termopar. Bez pola magnetycznego oraz dla indukcji magnetycznej poniżej 1 Tesli w naczyniu nie obserwowano ruchu konwekcyjnego, a co za tym idzie również żadnej struktury przepływu. Dla indukcji magnetycznej powyżej 1 Tesli w naczyniu eksperymentalnym została zapoczątkowana konwekcja magnetyczna, co objawiło się pojawieniem struktury szprychowej. Struktura szprychowa, typowa dla konwekcji naturalnej w termosyfonie (tzn. górna część cylindra chłodzona, a dolna grzana) uległa zmianie - wraz ze wzrostem indukcji magnetycznej wzrastała liczba płatków, co sugerowało intensyfikację konwekcji. Wyniki wizualizacji zostały potwierdzone przez pomiary termiczne oraz wyznaczoną liczbę Nusselta.
Źródło:
Journal of Theoretical and Applied Mechanics; 2007, 45, 3; 557-568
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reverse reaction magnetic field in two-wire high current busduct
Autorzy:
Piatek, Z.
Kusiak, D.
Szczegielniak, T.
Powiązania:
https://bibliotekanauki.pl/articles/97489.pdf
Data publikacji:
2010
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
magnetic field
high-current busduct
elliptical field
Opis:
Work has shown how a reverse reaction magnetic field influences the whole magnetic field within the conductor and its vicinity. A description of this is presented in formulae for relative field values and parameters taking into account frequency, conductivity and diameter of the conductor. This has shown the field to be an elliptical field.
Źródło:
Computer Applications in Electrical Engineering; 2010, 8; 53-60
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of time-stepping methods for transient magnetic field computations in COMSOL Multiphysics
Autorzy:
Sowa, M.
Typańska, D.
Powiązania:
https://bibliotekanauki.pl/articles/378331.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
time-stepping
COMSOL
transient magnetic field
Opis:
The computations of a transient magnetic field problem are presented. The problem has been constructed and solved in COMSOL Multiphysics which is one of the most popular and versatile commercial programs that allow to deal with solving electromagnetic field problems by means of the finite element method. A simple 2D problem of a coaxial cable has been chosen so that an analytical solution can be used in order to easily compute an error. The main topic of the paper concerns the comparison of the time-stepping methods that are available in COMSOL Multiphysics i.e. the BDF and generalized alpha methods. It is also possible to select various options for these methods, which have an influence on the solution accuracy. These have been also considered in the analysis.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 77; 141-147
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies