Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "MLRA - multilinear regression analysis" wg kryterium: Temat


Wyświetlanie 1-1 z 1
Tytuł:
Source apportionment of the PM10 fraction of particulate matter collected in Kraków, Poland
Autorzy:
Samek, L.
Powiązania:
https://bibliotekanauki.pl/articles/146888.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
air pollution
energy dispersive X-ray fluorescence (EDXRF)
elemental concentration
particulate matter
statistical analyses
PCA - principal component factor analysis
MLRA - multilinear regression analysis
Opis:
Samples of PM10 fraction of air particulates were collected during the winter of 2010 at two different sites in the City of Kraków, Poland. One site was located nearby a steel mill (Nowa Huta district) and the second one was situated at a distance of 10 km from the first site (Krowodrza district). The measured mass concentrations of PM10 fraction were in the range of 33 to 358 μg/m3. They exceeded the permissible daily limit value of 50 μg/m3. The Voivodship Inspectorate for Environmental Protection in Kraków was in charge of collecting samples as well as determining mass concentrations. Assessment of elemental concentrations and statistical analyses were performed at the University of Science and Technology in Kraków. Mean concentrations of Ti, Cu, Br and Pb were almost the same at both sites, while those of K, Ca and Zn were two times higher at Nowa Huta than at Krowodrza. Cr, Mn and Fe mass concentrations were also higher at Nowa Huta site; the values were a factor of three higher for Cr and Mn and factor of four for Fe. Factor analysis (FA) and multilinear regression analysis (MLRA) were used to determine source contributions to ambient PM10. The measurements were based on PM10 composition data which included elemental concentrations. Local combustion, industry and other, not identified sources, such as secondary aerosols, were the factors that highly contributed to the pollution of PM10 during winter time. For the site at Nowa Huta 53.1% of pollution was attributable to combustion and traffic, 28.5% was due to industry and wood combustion, and 18.3% were not identified. For the Krowodrza site, industry and wood combustion contributed 46.1%, combustion and traffic 50.4% and other, not identified sources 3.5% of the total PM10. Examination of meteorological data suggested that the concentration of potassium was inversely proportional to ambient air temperature at both sites. A wood combustion was identified as possible source of potassium in PM10.
Źródło:
Nukleonika; 2012, 57, 4; 601-606
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies