Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Inverter" wg kryterium: Temat


Tytuł:
Selection of 5 kW Converter Leg for Power Electronic System
Autorzy:
Zygmanowski, M.
Michalak, J.
Jeleń, M.
Jarek, G.
Powiązania:
https://bibliotekanauki.pl/articles/973060.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
IGBT
Silicon Carbide (SiC)
MOSFET
Inverter
Microgrid
Opis:
Three converter leg variants are analyzed for low power converter used for power electronic system for residential buildings. The two-level Si-IGBT and SiC-MOSFET converters are compared with Si-IGBT three-level T-type converter. Power losses generated in each of these converters over a predicted period of 20 years of operation are contrasted with the cost of converter options. The detailed selection procedure for output inductor is presented in this paper. This procedure shows the influence of the inductor parameters like number of turns, air gap length on its losses, cost and size. Theoretical approach is verified with simulations and experimental results.
Źródło:
Measurement Automation Monitoring; 2017, 63, 8; 282-287
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamiczna regulacja mocą przekształtników sieciowych
Dynamic power control of the grid converters
Autorzy:
Zieliński, D.
Powiązania:
https://bibliotekanauki.pl/articles/407678.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
przekształtnik
VOC
LVRT
Simulink
inverter
PI algorithm
Opis:
Dynamicznie rozwijający się sektor źródeł odnawialnych zmusza urząd regulacji energetycznej do wprowadzania coraz bardziej rygorystycznych norm odnośnie jakości dostarczanej energii i dynamiki samych źródeł. W przyszłości przepisy będą wymagały by źródło energii odnawialnej własnościami dynamicznymi przypominało generator synchroniczny o równoważnej mocy. Ponadto źródło powinno własności tłumienia oscylacji mocy w systemie elektroenergetycznym i powinno wspomagać sieć w odbudowie napięcia. Powyższe przyczyny implikują sterowanie nieliniowe wysokiej dynamiki układów pośredniczących pomiędzy źródłem a siecią jakim są przekształtniki. Artykuł prezentuje regulator nieliniowy poprawiający dynamikę sterowania mocą w układach przekształtników wektorowych. Analizę dokonano za pomocą oprogramowania Matlab/SIMULINK.
The dynamic growth of the renewable energy sources sector causes that the Energy Regulatory Office introduces stricter and stricter grid codes about quality of the energy and dynamics of the sources. In the future, grid codes will require that the dynamic properties of the renewable source of energy is similar to the synchronous generator with the same power. Moreover, the renewable source of energy should damp power oscillation in power grid, and support it to stabilize the voltage. These causes lead us to use a high dynamic nonlinear control system – converters, installed between a source and a power grid. The paper presents a nonlinear controller improves the dynamic power control of the vector inverters’ systems. The analysis was made by using the MATLAB/Simulink software.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2016, 1; 59-62
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel in-phase disposition SPWM pulse allocation strategy for cascaded H-bridge inverter
Autorzy:
Zhang, Y.
Xiong, J.
Kong, L.
Wang, X.
Powiązania:
https://bibliotekanauki.pl/articles/141155.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
in-phase disposition SPWM
Inverter
CHB
THD
Opis:
A novel in-phase disposition (IPD) SPWM pulse allocation strategy applied to a cascaded H-bridge (CHB) converter is presented in this paper. The reason causing the power of the CHB converter imbalance is analyzed according to the traditional structure, the conception of power imbalance degree is introduced and the principle of the novel in-phase disposition SPWM allocation strategy is deduced in detail. The new pulse allocation scheme can ensure the power balance in 3/4 cycles through interchanging the PWM pulse sequence of the different CHB cell, meanwhile it makes the full advantage of the IPD control strategy, lower the total harmonic distortion (THD) of line voltage compared to a carrier phase shifted (CPS) control strategy, which is verified by theoretical derivation. A seven-level cascaded inverter composed by three H-bridge cells is taken as the example. The simulation and experiment is performed. The results indicate the validity of the analysis and verify the effectiveness of the proposed SPWM allocation strategy.
Źródło:
Archives of Electrical Engineering; 2018, 67, 2; 361--375
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on hybrid topology of single-switch ICPT for battery charging
Autorzy:
Zhang, Guangzong
Wang, Chunfang
Zheng, Jianfen
Li, Houji
Powiązania:
https://bibliotekanauki.pl/articles/949898.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
constant current
constant voltage
higher harmonics
ICPT
single-switch
inverter
Opis:
In order to realize constant current and constant voltage charging for batteries by inductively coupled power transfer (ICPT) technology, a single-switch CL/LCL circuit is designed. The single-switch CL/LCL circuit is composed of a CL/LCL compensation network and single-switch inverter. The proposed circuit is compared with the traditional constant current and constant voltage circuit in the structure. The operating process of the single-switch CL/LCL circuit and the principle to realize a zero-voltage switch (ZVS) are analysed in detail in this paper. The voltage gain and current gain of the circuit are calculated, which demonstrates that the circuit is able to suppress higher harmonics strongly. By using Fourier decomposition, the voltage on the primary-side compensation capacitor can be obtained. After constructing the equivalent mutual inductance model of the circuit, the formulas and parameters are deduced and calculated. Finally, an experiment platform is built to verify the proposed circuit can realize constant current and constant voltage.
Źródło:
Archives of Electrical Engineering; 2020, 69, 4; 841-855
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on topology of a novel three-phase four-leg fault-tolerant NPC inverter
Autorzy:
Zhang, Baoge
Ping, Shanyan
Long, Yyi
Jiao, Yyuemin
Wu, Bboxiang
Powiązania:
https://bibliotekanauki.pl/articles/2086722.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fault tolerant operation
midpoint potential equilibrium
NPC inverter
topology reconstruction
Opis:
Diode neutral point clamped (NPC) three-level converters have been widely used in recent years. Aiming at the problems of the high device failure rate and unstable neutral point potential of NPC three-level converters, an NPC three-level circuit with fourth bridge arm redundancy is proposed based on the traditional NPC three-level converter. The redundant fourth bridge arm is used to realize the function of stabilizing voltage when there is no fault and replacing the fault half-bridge arm to maintain the continuous operation of the converter when there is a fault. By analyzing the working principle of space vector pulse width modulation (SVPWM) and the power loss of the switch, it is of particular significance to the design and control of NPC three-level converters in the future. Matlab/Simulink verifies the feasibility of the fault-tolerant circuit structure.
Źródło:
Archives of Electrical Engineering; 2022, 71, 2; 489--506
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zwiększenie częstotliwości łączeń w falownikach dzięki nowym elementom półprzewodnikowym z węglika krzemu (SiC)
Autorzy:
Zdanowski, M.
Sobieski, R.
Powiązania:
https://bibliotekanauki.pl/articles/302847.pdf
Data publikacji:
2017
Wydawca:
Wydawnictwo Druk-Art
Tematy:
falownik
element półprzewodnikowy
węglik krzemu
inverter
semiconductor element
silicon carbide
Opis:
Doskonałe właściwości statyczne i dynamiczne tranzystorów SiC MOSFET mogą być wykorzystane do przesunięcia obecnej bariery częstotliwości łączeń, występującej w dotychczas stosowanych krzemowych (Si) elementach półprzewodnikowych falowników napięcia w zakres nawet powyżej 100 kHz.
Źródło:
Napędy i Sterowanie; 2017, 19, 3; 22-24
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary napięcia zasilania stojana silnika w napędzie falownikowym
Measurements of stator voltage in the inverter-fed drive system
Autorzy:
Zawarczyński, Ł.
Stefański, T.
Powiązania:
https://bibliotekanauki.pl/articles/314146.pdf
Data publikacji:
2016
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
napęd falownikowy
stojan silnika
napięcie fazowe
napięcie międzyfazowe
pomiar wartości chwilowej
inverter-fed drive system
motor stator
phase voltage
interphase voltage
measurement of temporary values
Opis:
W artykule przedstawiono analizę układów pomiarowych napięć stojana silnika zasilanego z falownika napięcia. Badania eksperymentalne układów pomiarowych przeprowadzono pod kątem oceny ich pasma przenoszenia, właściwości dynamicznych i dokładności pomiaru. Przedstawiono metody pomiaru wartości chwilowych napięć fazowych i międzyprzewodowych. Testy eksperymentalne przeprowadzono na stanowisku badawczym napędu falownikowego z silnikiem asynchronicznym o mocy 2,6 kW.
This paper presents an analysis of the measuring systems of the stator voltage of inverter-fed motor drive system. Experimental tests of measurement systems were carried out to calculate their bandwidth, dynamic properties and accuracy. The methods of measuring the temporary values of the phase voltages and interphase voltages. Experimental tests were carried out on the inverter-fed drive system with asynchronous motor with a power of 2,6 kW.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2016, 17, 12; 1514-1518
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analytical method of a calculation of a torque ripple of a two-phase asynchronous motor supplied by a pwm controlled inverter
Metoda analityczna obliczania pulsacji momentu dwufazowego silnika asynchronicznego zasilanego z falownika PWM
Autorzy:
Záskalický, P.
Powiązania:
https://bibliotekanauki.pl/articles/1368690.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
asynchronous motor
PWM controlled inverter
modeling
analytical method
Opis:
The paper deals with steady state calculation of torque and currents ripples of a two-phase asynchronous machine, which is supplied by an IGBT transistors half-bridge connected inverter. The inwerter output voltage is controlled by a PWM of the input DC voltage. The complex Fourier series analysis of the inverter output voltage was made, to obtain a spectrum of the harmonic supply voltages. The different voltage harmonic was applied to the two-phase induction machine model to obtain the electromagnetic torque and currents waveforms for various operation conditions.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 4, 100/2; 131-135
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical model of a single-phase inverter’s with voltage regulation
Autorzy:
Zaskalicky, P.
Zaskalicka, M.
Powiązania:
https://bibliotekanauki.pl/articles/2056350.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
model matematyczny
przekształtnik
regulacja napięcia
mathematical model
single-phase inverter
voltage regulation
Opis:
The paper deals with mathematical model of single-phase bridge inverters which outputs voltage is controlled by a pulse-width notching. The transistors in the inverter circuit are turned on and off so as to produce zero periods of equal length, for unipolar modulation, or negative voltage for bipolar modulation. The D.C. source is being a fixed level of voltage. Suppose the notching frequency to be constant for all frequency of the fundamental squarewaves and to be fixed on 500 Hz. The output inverter’s voltage is expressed by an analytical formula based on Fourier complex series. On the base of output voltage, the waveforms of the output currents are analytically calculated for different inverter’s loads.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2009, 83; 41-45
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Torque ripple calculation of a permanent magnet synchronous motor supplied by a three phase inverter with PWM
Autorzy:
Zaskalicky, P.
Powiązania:
https://bibliotekanauki.pl/articles/1372789.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik synchroniczny
magnes trwały
przekształtnik
synchronous motor
permanent magnet
inverter
Opis:
A steady-state analysis of a permanent magnet synchronous motor drive with a voltage-source inverter is presented. The torque-speed profile required of the drive is a constant torque region from zero to the base speed and a constant power region above base speed. A Fourier series approach is used to predict the line current waveform. Assuming the output inverter's voltage is controlled by a pulse-width notching. Suppose the notching frequency to be constant for all frequency of the fundamental squarewave and to be fixed on 500 Hz. The permanent magnet synchronous motor model is obtained from its analogy to the fixed-excited synchronous motor. From the induced voltage and line current waveforms the electromagnetic torque ripple waveform is calculated.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2010, 88; 81-86
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
O kształcie napięcia wyjściowego falownika pomocniczego pojazdu trakcyjnego na podstawie analizy z wykorzystaniem wektora przestrzennego
The shape of output volt- i age of the auxiliary inverter of traction vehicle based on the analysis using the spatial vector
Autorzy:
Żarnowski, Roman
Płachtyna, Omelian
Kłosowski, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/34595792.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Poznański Instytut Technologiczny
Tematy:
napięcie wyjściowe
falownik napięcia
pojazd trakcyjny
wektor przestrzenny
transformator trójfazowy
napięcie trójfazowe
output voltage
voltage inverter
traction
space vector
three-phase transformer
three-phase voltage
Opis:
Współczesne układy elektryczne często są zasilane ze źródeł napięcia odkształconego pochodzącego z przekształtników energoelektronicznych. Artykuł jest opisem pracy pewnego nowego układu trójfazowego kaskadowego falownika napięcia z trójfazowym transformatorem, jako źródła napięcia bez wyższych harmonicznych do rzędu 10 włącznie, lub w wersji rozbudowanej bez harmonicznych do rzędu 22, na podstawie analizy z wykorzystaniem pojęcia wektora przestrzennego. Źródło trójfazowego napięcia o takiej jakości napięcia jest wystarczające do zasilenia obwodów pomocniczych prądu przemiennego pojazdu trakcyjnego, jak i może zasilać sieć autonomiczną, w tym silniki indukcyjne.
The modern electrical systems are often supplied from the deformed i voltage sources derived from the energy-electronic converters. The article is a description of operation of a i new three- phase cascade inverter of 1 voltage with the three-phase transformer as the voltage source without i the higher harmonics up to the order of 10 inclusive or in the extended t version without harmonics up to the order of 22 based on the analysis with s using the notion of spatial vector. Three-phase voltage source with such voltage quality is sufficient to supply a the AC auxiliary circuits of the traction vehicle and it can power the a autonomous network including the induction motors.
Źródło:
Rail Vehicles/Pojazdy Szynowe; 2014, 4; 6-13
0138-0370
2719-9630
Pojawia się w:
Rail Vehicles/Pojazdy Szynowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency comparison between the LLCL and LCL-filters based single-phase grid-tied inverters
Autorzy:
Wu, W.
Huang, M.
Blaabjerg, F.
Powiązania:
https://bibliotekanauki.pl/articles/140537.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
LCL filter
LLCL-filter
efficiency power loss
modulation
single-phase grid-tied inverter
Opis:
An LLCL-filter is becoming more attractive than an LCL-filter as the interface between the grid-tied inverter and the grid due to possibility of reducing the copper and the magnetic materials. The efficiency of the LLCL-filter based single-phase grid-tied inverter also excites interests for many applications. The operation of the switches of the VSI is various with different modulation methods, which lead to different efficiencies for such a single-phase grid-tied inverter system, and therefore important research has been carried out on the effect of the choice of PWM schemes. Then power losses and efficiencies of the LLCL-filter and the LCL-filter based single-phase grid-tied inverters are analyzed and compared under the discontinuous unipolar, the dual-buck and the bipolar modulations. Results show that the efficiency of LLCL-filter based inverter system is higher than the LCL- filter based independent on the modulation method adopted. Experiments on a 2 kW prototype are in good agreement with results of the theoretical analysis.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 63-79
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of mechanical and electromagnetic phenomena on electric motor vibrations in different power supply options
Autorzy:
Wróbel, Mateusz
Barczewski, Roman
Jakubek, Bartosz
Rukat, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/2146620.pdf
Data publikacji:
2020
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
electric motor
vibration
supply
star
single-phase
inverter
multi-synchronous averaging
silnik elektryczny
drgania
zasilanie
gwiazda
zasilanie jednofazowe
falownik
uśrednianie multisynchroniczne
Opis:
Results of research about influence of mechanical and electromagnetic phenomena on electric motor vibration in different supply options has been shown in this paper. Three different supply options have been taken under consideration: typical star connection, single-phase connection with work capacitor and connection through an inverter. Vibration signals recorded on electric motor end shield and frame has been digitally processed using Multi-Synchronous Averaging (MSA). This technique allowed to decompose total vibration signal into signals associated with mechanical and electromagnetic phenomena occurring in electric motor. The comparison of rms values and spectra shapes of total and decomposed vibration signals has been made. Energy shares of previously mentioned phenomena in vibration signal for different supply options has been also estimated.
Źródło:
Vibrations in Physical Systems; 2020, 31, 1; art. no. 2020102
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Regulacja wydajności urządzeń potrzeb własnych elektrowni cieplnych asynchronicznymi napędami falownikowymi średniego napięcia
Variable speed drives with frequency converters in thermal power plant auxiliaries
Autorzy:
Wawszczak, A.
Powiązania:
https://bibliotekanauki.pl/articles/173004.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrownia cieplna
napęd falownikowy
przemiennik
thermal power station
inverter drive
inverter
Opis:
Omówiono możliwości regulacji wydajności urządzeń potrzeb własnych elektrowni cieplnych napędzanych klatkowymi silnikami indukcyjnymi zasilanymi przemiennikami częstotliwości. Skupiono się głównie na napędach średnionapięciowych (6÷10 kV) dużej mocy. Przedstawiono aktualną ofertę przemienników czołowych światowych producentów. Oceniono możliwości wykorzystania tego typu napędów w dużych, nowoczesnych elektrowniach blokowych.
The paper introduces current potential of variable speed drives (VSD) intended for squirrel cage induction motors supplied by frequency converters in thermal power plant auxiliaries. The paper is mostly focused on medium-voltage (6-10 kV) and high-power drives. Current tender of leading world producers in this field has been presented. Possibility to apply this type of drives in large, modern block-power plants has been considered.
Źródło:
Archiwum Energetyki; 2013, 43, 1/2; 87-99
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Train based on virtual synchronous generator technology uninterrupted phase-separation passing study
Autorzy:
Wang, Ying
Yang, Huan
Chen, Xiaoqiang
Guo, Ya
Powiązania:
https://bibliotekanauki.pl/articles/27309940.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
energy storage railway power conditioner
single-phase inverter
uninterrupted
phase-separation passing
virtual synchronous generator
Opis:
The problem of large speed loss exists in the traditional passing through the electric phase-separation method of trains, which is more prominent when trains pass through an electric phase-separation zone in the uphill section of long ramps and may lead to the trains not passing through the phase-separation zone safely. In order to solve this problem, based on the energy storage type railroad power conditioner, a train uninterrupted phase-separation passing system based on the energy storage type railroad power conditioner is proposed. The energy storage railroad power conditioner can realize the recovery and utilization of regenerative braking energy of the electrified railroad. In the structure of the energy storage railroad power conditioner, the single-phase inverter is led from the middle DC side of the energy storage railroad power conditioner and connected to the neutral line through the LCL filter and the step-up transformer, which constitutes an uninterrupted phase separation passing system. The single-phase inverter is controlled using virtual synchronous generator technology, which allows the single-phase inverter to have external characteristics similar to those of a synchronous generator, providing support for the voltage and frequency in the neutral zone. The power required by the train to pass the electric phase-separation is provided by the power supply arm or the energy storage system, which not only improves the utilization rate of regenerative braking energy but also realizes the uninterrupted phase separation passing of the train through the control of the voltage in the neutral region.
Źródło:
Archives of Electrical Engineering; 2023, 72, 3; 755--768
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies