Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Inverter" wg kryterium: Temat


Tytuł:
Feedback control of three-Level PWM rectifier: Application to the stabilization of DC Voltages of five-level NPC active power filter
Autorzy:
Abdelkrim, T.
Berkouk, E. M.
Benslimane, T.
Benamrane, K.
Powiązania:
https://bibliotekanauki.pl/articles/229851.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active power filter
NPC multilevel inverter
feedback control
PWM current rectifier
clamping bridge filter
Opis:
One of the most important drawbacks of the three phases five-level NPC (Neutral Point Clamped) Active Power Filter (APF) is the neutral point balance. As the consequence, the capacitors voltages of the input DC bus of the APF are not equal which constitutes the major limitation for the use of this power converter. In order to stabilize these DC voltages, it is proposed in this paper to study the cascade constituted by three phases three-level PWM rectifier-clamping bridge filter-five-level NPC APF. In the first part, the authors present a topology of five-level NPC Voltage Source Inverter (VSI), and then, they propose a model of this converter and its PWM control strategy. In the second part, the modeling and control of three-level PWM current rectifier is presented. In the third part, to remedy to instability problem of the input capacitors DC voltages of the APF, the authors propose feedback control of the three-level PWM rectifier followed by clamping bridge filter. After that, the sliding mode regulator used to control the active filter is developed. The obtained results are full of promise to use this topology of APF in high voltage and high power applications.
Źródło:
Archives of Control Sciences; 2010, 20, 3; 317-339
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Passive filter design for three-phase inverter interfacing in distributed generation
Autorzy:
Ahmed, K. H.
Finney, S. J.
Williams, B. W.
Powiązania:
https://bibliotekanauki.pl/articles/262578.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
DG
inverter
grid connected
filtering
damping
harmonics
Opis:
With the growing use of inverters in distributed generation, the problem of injected harmonics becomes critical. These harmonics require the connection of low pass filters between the inverter and the network. This paper presents a design method for the output LC filter in grid coupled applications in distributed generation systems. The design is according to the harmonics standards that determine the level of current harmonics injected into the grid network. Analytical expressions for the maximum inductor ripple current are derived. The filter capacitor design depends on the allowable level of switching components injected into the grid. Different passive filter damping techniques to suppress resonance affects are investigated and evaluated. Simulated results are included to verify the derived expressions.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2007, 13, 2; 49-58
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modified Topology and Modulation Technique for Z-Source Neutral-Point Clamped Inverter
Autorzy:
Akbari, Ehsan
Zishan, Farhad
Powiązania:
https://bibliotekanauki.pl/articles/2175930.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
modulation
optimization
multilevel inverter
MZS-NPC
Opis:
The impedance network makes it possible to increase and decrease the voltage, which is not available in normal inverters (voltage and current sources).This paper presents a modified topology and modulation technique for a three-phase Modified Z-Source Neutral-Point Clamped (MZS-NPC) inverter. A modulation scheme for the proposed topology is designed based on maximum gain control method to achieve the maximum voltage gain by simple implementation and balancing the neutral point voltage of the dc link. In order to supply the desired voltage to the critical load in an islanded micro-grid, a closed-loop ac voltage controller is realized in fuel cell or photovoltaic applications based on the proposed inverter. The ability to reinforce and validity of topology operations and modulation techniques has been demonstrated by simulation. It should be noted that the simulations are implemented in MATLAB / Simulink software.
Źródło:
Power Electronics and Drives; 2022, 7, 42; 210--226
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of numerically determined noise of a 290 kW induction motor using fem and measured acoustic radiation
Autorzy:
Al Nahlaoui, M.
Steins, H.
Kulig, S.
Exnowski, S.
Powiązania:
https://bibliotekanauki.pl/articles/1813585.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
inverter-fed
induction motor
asynchronous machine
acoustic radiation
FEM
noise
surface vibration
modal analysis
Opis:
Abstract - In this paper a comparison of numerically determined and measured electromagnetically exited noise of an induction motor is presented. The calculations are accomplished using FEM for an example motor, which is a 290 kW inverter-fed asynchronous machine. The approach starts with the electromagnetic and mechanical consideration. The focus is set on acoustic considerations, which contain the 3D-FE-model and measurement setup in the sound chamber. The determination of the induction and force waves is presented using parts of the results. In the case of the mechanical modeling the three dimensional FE-model is shown.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2012, 66, 32; 333-338
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Generalized space vector control for current source inverters and rectifiers
Autorzy:
Anitha Roseline, J.
Senthil Kumaran, M.
Rajini, V.
Powiązania:
https://bibliotekanauki.pl/articles/140525.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current source rectifiers (CSR)
current source inverters (CSI)
current source multilevel inverter (CSMLI)
space vector pulse width modulation (SVPWM)
Opis:
Current source inverters (CSI) is one of the widely used converter topology in medium voltage drive applications due to its simplicity, motor friendly waveforms and reliable short circuit protection. The current source inverters are usually fed by controlled current source rectifiers (CSR) with a large inductor to provide a constant supply current. A generalized control applicable for both CSI and CSR and their extension namely current source multilevel inverters (CSMLI) are dealt in this paper. As space vector pulse width modulation (SVPWM) features the advantages of flexible control, faster dynamic response, better DC utilization and easy digital implementation it is considered for this work. This paper generalizes SVPWM that could be applied for CSI, CSR and CSMLI. The intense computation involved in framing a generalized space vector control are discussed in detail. The algorithm includes determination of band, region, subregions and vectors. The algorithm is validated by simulation using MATLAB /SIMULINK for CSR 5, 7, 13 level CSMLI and for CSR fed CSI.
Źródło:
Archives of Electrical Engineering; 2016, 65, 2; 235-248
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
CHB inverter with DC-link capacitor balancing and total harmonic minimization
Autorzy:
Armi, F.
Manai, L.
Besbes, M.
Powiązania:
https://bibliotekanauki.pl/articles/141332.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CHB inverter
capacitor voltage balancing
switching angles
Newton Raphson
algorithm
SHE
THD
Opis:
A cascaded H-bridge (CHB) multilevel inverter generally requires several DC sources. An alternative option is to replace the separate DC source feeding an H-bridge cell with a capacitor, while maintaining the other H-bridge cell with a real DC voltage source. In this paper a 7-level cascaded H-bridge inverter with a single DC-source is presented. This paper focuses mainly to achieve effective capacitor voltage balancing and selective harmonic elimination (SHE) based on the Newton Raphson algorithm (N–R). It shows hope to reduce the voltage ripple of the capacitors, which leads to higher power conversion efficiency with equal power distribution, reduces the initial cost, and complexity hence it is apt for industrial applications. Simulation results support the proposed control technique.
Źródło:
Archives of Electrical Engineering; 2018, 67, 1; 81-93
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterowanie wielopoziomowym filtrem aktywnym z selektywną kompensacją harmonicznych
Control of multilevel active power filter with selective harmonic compensation
Autorzy:
Banach, P.
Cichowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/268282.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
filtr aktywny
selektywna kompensacja harmonicznych
falownik wielopoziomowy NPC
active power filter
selective compensation
multilevel inverter NPC
Opis:
W artykule przedstawiono metodę sterowania wielopoziomowym równoległym filtrem aktywnym z możliwością selektywnej kompensacji wybranych harmonicznych prądu z uwzględnieniem ograniczeń prądowych przekształtnika. Falownik wielopoziomowy umożliwia dokładniejsze generowanie napięcia wyjściowego przy mniejszej częstotliwości modulacji oraz umożliwia zmniejszenie wymiarów filtrów sieciowych względem klasycznego falownika dwupoziomowego. Użycie algorytmu selektywnej kompensacji pozwala na zastosowanie przekształtnika o mniejszej mocy i skompensowanie tylko wybranych wyższych harmonicznych. Przedstawiono wyniki symulacji wykonanej w programie Matlab proponowanej metody sterowania, którą oparto na algorytmie adaptacyjnym na przykładzie wybranej harmonicznej.
In this paper a control method of multilevel active power filter (APF) with selective harmonic compensation (SHC) is presented. The parallel APF is one of the most popular topology of the power quality improvement devices and is connected between power coupling point and nonlinear load to compensate current harmonics. Nowadays multilevel converters become increasingly popular because of its advantages such as: low output voltage THD, lower current ripple, low grid filters size and weight, possibility of using lower voltage of semiconductors. There are a lot of papers concerning SHC, but most of them do not consider maximum current limit of the inverter. The APF uses Phase Locked Loop to synchronise with the grid and to eliminate harmonics in the grid voltage a Cascaded Delayed Signal Cancellation is implemented. The reference current is estimated by adaptive filter using least means squares learning method with estimated value limitation. In order to generate compensation current a predictive controller is implemented. Output voltages generation and stabilization of neutral point voltage of the multilevel inverter is based on a shape-function space vector modulator. The simulation in Matlab is prepared.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 19-22
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kompleksowy napęd elektryczny przeznaczony dla jednostek pływających
Autorzy:
Barański, Marcin
Decner, Adam
Jarek, Tomasz
Maciążek, Marcin
Litwinowicz, Adam
Powiązania:
https://bibliotekanauki.pl/articles/31804061.pdf
Data publikacji:
2024
Wydawca:
Wydawnictwo Druk-Art
Tematy:
napęd elektryczny
napęd łodzi
elektromobilność
falownik
ładowarka
electrical drive
boat drive
electromobility
inverter
charger
Opis:
Complehensive electric drive dedicated to watercrafts
Źródło:
Napędy i Sterowanie; 2024, 26, 3; 72-78
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part I
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114413.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 322-324
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part II
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114230.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 325-328
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przemiennik częstotliwości jako nieliniowy odbiornik energii
Frequency inverter as a non-linear energy loads
Autorzy:
BARTMAN, Jacek
SOBCZYŃSKI, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/455461.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Rzeszowski
Tematy:
nieliniowe odbiorniki energii przemiennik częstotliwości
non-linear energy loads
inverter
Opis:
Artykuł przedstawia zagadnienia związane z pracą nieliniowych odbiorników energii. Określa, jakie odbiorniki uznaje się za nieliniowe, a jakie za liniowe. Jako przykład odbiornika nieliniowego pokazany jest przemiennik częstotliwości pracujący w układzie napędowym z regulowaną prędkością obrotową. Pokazano odkształcenia napięcia i prądu wywołane pracą napędu.
The work presents the issues associated with the functioning of non-linear receivers of the energy. It determines, what receivers are being regarded non-linear and which too linear. As the example of the non-linear receiver a inverter working in the driving system with the adjusted rotation speed is shown. Showing voltage and current distortion caused by the drive.
Źródło:
Edukacja-Technika-Informatyka; 2016, 7, 4; 394-399
2080-9069
Pojawia się w:
Edukacja-Technika-Informatyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A method of reducing switch count in three-level NPC inverter – analysis in steady states
Autorzy:
Beniak, R.
Rogowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/1193464.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
reduction of switch count
three-level NPC inverter
space vector modulation
Opis:
The proof of a concept for a new method of modulation has been presented which reduce switch count in a three-level neutral point clamped (3L-NPC) inverter. The method is an implementation of space vector modulation (SVM) by means of a prediction algorithm and sequences of transistors, which are not common in use. Those sequences make active use of clamping diodes of the inverter. The prediction algorithm analyzes possible sequences of transistors’ states and choose those which offers smaller switch count. Measurements of steady states were taken on prototype 3L-NPC.
Źródło:
Power Electronics and Drives; 2017, 2, 37/2; 117-126
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A method of reducing switching losses in three-level NPC inverter
Autorzy:
Beniak, R.
Rogowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/1193262.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
reduction of switching losses
three-level NPC inverter
space vector modulation
Opis:
The aim of the paper is to present a concept of implementation of a space vector modulation (SVM) algorithm, which is used to create alternating current waveforms of changing amplitude and frequency in power inverters. The main goal of the method is to decrease the number of state changes in power transistors. It is realized by utilizing a prediction algorithm and sequences of transistors, which are not common in use. The method requires measurement of inverter output current flow. The prediction algorithm analyzes possible sequences of transistors’ states and choose those which offers smaller switch count. A decrease of about 20% was obtained for the cases tested. This paper presents simulation result for selected driving scenario. The described method decreases the number of state changes in power transistors and therefore it is a potentially good method to considerably decrease energy losses of multilevel inverter-powered drive.
Źródło:
Power Electronics and Drives; 2016, 1, 36/2; 55-63
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of asymmetrical currents waveforms to detect and localize open switch faults for two level voltage source inverter three-phase shunt active power filter
Autorzy:
Benslimane, T.
Chetate, B.
Abdelkrim, T.
Powiązania:
https://bibliotekanauki.pl/articles/229453.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active power filter
fault detection
two level there phase voltage source inverter
current mean value
Opis:
This paper proposes an open switch faults detection and localization algorithm for shunt three phase active filter topology. It mainly details converter configuration and examines a simple and reliable optimized fault diagnosis method. The converter topology is based on classical three-leg active power filter topology. New fault diagnosis method is proposed, based on classical currents measurements. It includes combinatory logic to analyze and validate error signals. Hysteresis control is applied before and after fault detection, which avoids any controller reconfiguration. Simulation results obtained with Matlab/Simulink/Plecs tools prove the effectiveness of this method.
Źródło:
Archives of Control Sciences; 2011, 21, 1; 105-117
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ochrona układu izolacyjnego transformatora współpracującego z falownikami
Protection of the transformer insulation system cooperating with inverters
Autorzy:
Bernatt, Jakub
Gawron, Stanisław
Glinka, Tadeusz
Polak, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2142529.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
transformator
falownik
kondensator
warystor
transformer
inverter
capacitor
varistor
Opis:
Farmy fotowoltaiczne są łączone z siecią elektroenergetyczną poprzez falownik DC/AC i transformator. Komutacja prądu w zaworach falownika generuje w indukcyjnościach rozproszenia impulsy napięcia, które oddziałują na układ izolacyjny uzwojeń transformatora. Skuteczną ochronę izolacji uzwojeń transformatora przed przepięcia stanowią filtry tłumiące. Mogą to być kondensatory bądź warystory. Filtr w sposób znaczący poprawia warunki dielektryczne izolacji uzwojenia transformatora.
The solar farms are connected to the electricity grid through a DC / AC inverter and a transformer. The current commutation in the inverter valves generates voltage pulses in the leakage inductances, which act on the insulation system of the transformer windings. Suppression filters provide effective protection of the transformer winding insulation against overvoltage. These can be capacitors or varistors. The filter significantly improves the dielectric conditions of the transformer winding insulation.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 41--44
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies