Tytuł:
Impact of operating conditions on the strength and frequency of destruction of fibre-cement composites
Wpływ warunków eksploatacyjnych na wytrzymałość i częstotliwości niszczenia kompozytów cementowo-włóknistych
Autorzy:
Adamczak-Bugno, Anna
Krampikowska, Aleksandra
Powiązania:
https://bibliotekanauki.pl/articles/1852563.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kompozyt cementowo-włóknisty
elewacja wentylowana
metoda emisji akustycznej
wytrzymałość na zginanie
fibre-cement composite
ventilated façade
acoustic emission method
bending strength
Opis:
The paper examines the impact of possible operational factors on strength and frequency parameters generated by bending of fibre-cement panels. The tests were performed on elements cut out of a standard commercially available panel. The samples were exposed to factors described as environmental (soaking in water, bath-drying cycles, freeze-thawing cycles) and unique (flame ignition and high temperature exposure) and then subjected to three-point bending tests. Acoustic emission (AE) signals were acquired during the external load application. After the measurements were completed, the strength of individual elements was determined and the frequencies generated during bending were calculated. The obtained results were analysed statistically. Comparing the results obtained for a group of samples subjected to environmental and unique factors, significant differences between them were noted. It was noted that the decrease in the strength of the samples is related to the emission of lower frequency sounds. It was found that the application of the presented methodology allows to determine the condition of the fibre-cement boards in use.
W artykule przedstawiono wyniki testów trzypunktowego zginania dla elementów włóknisto- cementowych poddanych działaniu czynników środowiskowych i wyjątkowych z jednoczesną akwizycją sygnałów AE. Analizie poddano wartości wytrzymałości na zginanie oraz częstotliwości generowanych przed momentem zniszczenia. Na podstawie otrzymanych wyników wyciągnięto następujące wnioski: Obniżenie wytrzymałości elementów włóknisto-cementowych wiąże się z generowaniem niższych częstotliwości przy zginaniu w odniesieniu do próbek o niezmienionych parametrach mechanicznych. Zastosowanie metody emisji akustycznej umożliwia śledzenie częstotliwości powiązanych z powstawaniem różnego rodzaju zmian w strukturze materiału. Przebieg procesu niszczenia struktury płyty cementowo-włóknistej jest mechanizmem złożonym i powiązanym w sposób ścisły z obecnością włókien zbrojących oraz stopniem wiązania pomiędzy zbrojeniem a matrycą. Częstotliwości generowane przez zmiany zachodzące w strukturze włókno-cementu są ściśle powiązane z obecnością zbrojenia w postaci włókien oraz stopniem wiązania między zbrojeniem a matrycą. Zastosowanie techniki emisji akustycznej umożliwia skuteczne wykrywanie i monitorowanie inicjacji zmian w strukturze wpływających na obniżenie parametrów mechanicznych płyt. Otrzymane rezultaty dają możliwość zastosowania metody AE do oceny stanu pełnowymiarowych elementach cementowo-włóknistych.
Źródło:
Archives of Civil Engineering; 2021, 67, 2; 67-83
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania nieniszczące urządzeń technicznych metodą emisji akustycznej
Non-destructive testing of technical equipment using acoustic emission method
Autorzy:
Baran, Ireneusz
Powiązania:
https://bibliotekanauki.pl/articles/107754.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
non-destructive testing
acoustic emission (AE)
testing using AE method – acoustic emission testing (AT)
badania nieniszczące
emisja akustyczna (AE)
badanie metodą AE – badanie AT
Opis:
Technical devices operating in industrial conditions are subject to periodic technical inspection, in accordance with the Regulation of the Council of Ministers of 07 December 2012 on the types of technical devices subject to technical supervision (Journal of Laws 2012 item 1468). As part of periodic inspections, supplementary non-destructive testing (NDT) are carried out, such as: eddy current tests - ET, leak tests - LT, magnetic powder tests - MT, penetration tests - PT, ultrasonic tests - UT and visual tests - VT. The research program and scope of actions depends on many factors, including the type of device, material used, degradation mechanisms occurring, operating conditions of the device, or its operating time. Another NDT test method that is more and more widely used is the acoustic emission method (def. AE - acoustic emission, AT - acoustic emission testing according to PN-EN 1330-9: 2017-09). The ability to detect and locate AE signal sources, as well the ability to perform tests during the operation of devices (in-service), makes that this method is now worldwide considered as suitable for periodic testing of large objects, among others in the petrochemical and chemical. AT test allows detecting damages at an early stage of their occurrence, as well as at the same time allowing to globally monitoring whole object. The AT test complements very well together with other NDT methods, what allows verification and more accurate assessment of the detected damages. In many cases, the AE method is one of several methods used to assess the technical condition of the device. AT is used first of all at the initial stage, in order to indicate areas to tests by other NDT methods - for this reason this method is often called the "screening method". This article presents the basics of the AE method and its practical applications.
Urządzenia techniczne pracujące w warunkach przemysłowych podlegają badaniom okresowym dozoru technicznego, zgodnie z Rozporządzeniem Rady Ministrów z dnia 07 grudnia 2012 r. w sprawie rodzajów urządzeń technicznych podlegających dozorowi technicznemu (Dz.U. 2012 poz. 1468). W ramach działań okresowych wykonywane są badania uzupełniające metodami nieniszczącymi (NDT), takimi jak: badania prądami wirowymi – ET, badania szczelności – LT, badania magnetyczno-proszkowe – MT, badania penetracyjne – PT, badania ultradźwiękowe – UT i badania wizualne – VT. Program badań i zakres czynności uzależniony jest od wielu czynników, w tym od rodzaju urządzenia, użytego materiału konstrukcyjnego, występujących mechanizmów degradacji, warunków pracy urządzenia czy też czasu jego eksploatacji. Inną metodą badań NDT, coraz szerzej stosowaną, jest metoda emisji akustycznej (def. AE – emisja akustyczna, AT – badanie emisją akustyczną wg PN-EN 1330-9:2017-09). Możliwość wykrywania i lokalizacji źródeł sygnałów AE oraz możliwość wykonania badań w trakcie eksploatacji urządzeń sprawia, że obecnie metoda ta jest na świecie uznawana za odpowiednią do badań okresowych dużych urządzeń, między innymi w przemyśle petrochemicznym i chemicznym. Badanie AT pozwala na ujawnienie uszkodzeń na wczesnym etapie ich występowania, a jednocześnie na objęcie badaniem całego obiektu. Badanie AT bardzo dobrze uzupełnia się z innymi metodami badań nieniszczących, co pozwala na weryfikację i dokładniejszą ocenę wykrywanych uszkodzeń. W wielu przypadkach metoda AE stanowi jedną z kilku wykorzystywanych metod do oceny stanu technicznego danego urządzenia. Stosuje się ją w pierwszej kolejności na etapie początkowym, w celu wskazania i uszczegółowienia miejsc do badania innymi metodami NDT – z tego powodu metoda ta często nazywana jest „metodą przesiewową”. W niniejszym artykule przedstawiono podstawy metody AE oraz jej praktyczne zastosowania.
Źródło:
Badania Nieniszczące i Diagnostyka; 2019, 4; 15-19
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mobilny system pomiarowy do badania zjawiska wyładowań niezupełnych metodą emisji akustycznej
: Mobile measuring system for investigating partial discharge phenomena by the acoustic emission method
Autorzy:
Błachowicz, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/155765.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metoda emisji akustycznej
wyładowania niezupełne
system czasu rzeczywistego
mobilny system pomiarowy
acoustic emission method
partial discharges
real time system
mobile measuring system
Opis:
W artykule przedstawiono założenia projektowe oraz sposób realizacji mobilnego sytemu umożliwiającego pomiary wyładowań niezupełnych (WNZ), jakie mogą występować w izolacji kondensatorów elektroenergetycznych do kompensacji mocy biernej, wykonywane przy zastosowaniu metody emisji akustycznej (EA). Zdefiniowana została podstawowa potrzeba budowy mobilnego systemu pomiarowego. Z uwagi na utrudniony dostęp oraz pracę w warunkach mogących bezpośrednio zagrozić życiu osób diagnozujących stan obiektu elektroenergetycznego, znajdującego się w rozdzieli średniego napięcia, detekcja zjawiska WNZ jest znacznie utrudniona. Autorzy prezentują rozwiązanie umożliwiające diagnozę prowadzoną zdalnie, z jednoczesną możliwością wykonywania pomiarów diagnostycznych układów izolacyjnych metodą on-line. Artykuł zawiera informacje dotyczące rozwiązań zastosowanych w systemie. System składa się z kilku, ściśle związanych ze sobą elementów, dla których przewidziano odpowiednie funkcje. Zaprezentowane zostały możliwości elementów takich jak aplikacja WNZDetect, robot mobilny oraz część pomiarowo detekcyjną. Zaprezentowany został robot o nazwie SQ1, który został wyposażony w kilka typów modułów. Są to: moduł główny, dwa moduły sterujące pracą kół oraz moduł monitorujący. W artykule scharakteryzowano ich funkcjonalność i rolę pełnioną w systemie. Autorzy opisali wykorzystany do oprogramowania modułów robota, system czasu rzeczywistego o nazwie Nut/OS. Przedstawione zostały również, zawarte w środowisku Ethernut (Nut/OS) biblioteki oraz funkcje poszczególnych pakietów. W podsumowaniu zdefiniowano dalsze perspektywy wykorzystania zbudowanego systemu w badaniu zjawiska WNZ.
The paper presents design assumptions and the way of realizing the mobile system which enables measurements of partial discharges (PDs) which can occur in insulation of electric power capacitors for compensation of reactive power. The measurements are taken by means of the acoustic emission (AE) method. The basic need for building a mobile measuring system is defined. Due to a difficult access and work under conditions which can be hazardous to lives of people diagnosing the condition of an electric power object in the mean-voltage switching station, the detection of the PD phenomenon is significantly difficult. The authors propose a solution making it possible to perform a remotely-controlled diagnosis with simultaneous possibility of taking diagnostic measurements of insulation systems by the on-line method. The paper contains information on the solutions applied in the system. The system consists of a few elements closely connected with one another for which adequate functions are predicted. The possibilities of such elements as the WNZDetect application, a mobile robot and a measuring and detecting part are given. Also a robot called SQ1 equipped with a few types of modules is presented. They are: the main module, two modules controlling the operation of the wheels and a monitoring module. Their functionality and the role in the system are characterized in the paper. The authors describe the real time system called Nut/OS used for programming the robot modules. There are also presented libraries and functions of the particular packets contained in the Ethernut (Nut/OS) environment. In the final remarks further perspectives of using this system in PD phenomenon investigations are defined.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 27-29
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System ekspertowy oceny stanu układów izolacyjnych transformatorów elektroenergetycznych z wykorzystaniem metody emisji akustycznej
Expert system for assessment of electric power transformer insulation systems using the acoustic emission method
Autorzy:
Boczar, T.
Frącz, P.
Powiązania:
https://bibliotekanauki.pl/articles/152181.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metoda emisji akustycznej
wyładowania elektryczne
wyładowania niezupełne
system ekspercki
wysokonapięciowe systemy izolacyjne
acoustic emission method
electrical discharge
partial discharge
expert system
high-voltage insulation systems
Opis:
Tematyka niniejszego artykułu dotyczy doskonalenia praktycznych zastosowań metody emisji akustycznej (EA) w diagnostyce wysokonapięciowych układów izolacyjnych urządzeń elektroenergetycznych. W szczególności przedstawiono podstawowe założenia oraz opisano poszczególne elementy eksperckiego systemu diagnostycznego wykorzystującego metodę akustyczną do oceny stanu mierzonej izolacji transformatorów energetycznych, wykonywanej podczas ich normalnej pracy w warunkach przemysłowych.
The subject matter of this paper refers to the development of practical applications of the acoustic emission (EA) method to diagnostics of high-voltage insulation systems of power appliances, carried out during their regular operation in industrial conditions. First of all, basic assumptions are presented and the particular elements of the expert diagnostic system using AE method for the assessment of the condition of the electric power transformer insulation measured are described. Fig. 1 shows its block diagram in which the following modules can be distinguished: a measuring system (Figs. 2 and 3), a processing - analysing system, a knowledge base and a classifier. These modules are characterised successively in Section 2 of the paper. Special attention is given to the description of the group of multiparametric descriptors (Fig. 4) characterising the AE signals in the time, frequency and time-frequency domains, including descriptive statistics indexes and correlative parameters. Accordant descriptors make it possible, under strictly defined metrological conditions, to recognize basic partial discharge forms (PDs) that may occur in paper-oil insulation. In this way a catalogued knowledge base containing the so-called 'fingerprints' was created for basic types of high-voltage defects of insulation systems. The scope of the research work carried out in the Institute of Power Engineering, connected with a practical implementation of the system suggested, is characterised in the last section of the paper.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 2, 2; 104-107
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie analizy MUSIC do oceny sygnałów zakłócających pomiary diagnostyczne układów izolacyjnych metodą emisji akustycznej
Application of the MUSIC analysis for evaluation of the signals interfering diagnostic measurements of insulation systems using acoustic emission method
Autorzy:
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/275014.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
wyładowania niezupełne
metoda emisji akustycznej
sygnał zakłócający
analiza sygnałów
partial discharges
acoustic emission method
interfering signal
signal analysis
Opis:
W artykule zostaną przedstawione wyniki analizy pseudospektralnej (Pseudo-Spectral Analysis) uzyskane dla akustycznych sygnałów zakłócających. Analizowane będą źródła zakłóceń, które mogą występować podczas pomiarów diagnostycznych układów izolacyjnych wykonywanych on-line metodą emisji akustycznej podczas normalnej eksploatacji transformatorów elektroenergetycznych. Uzyskane wyniki zostaną porównane z rezultatami otrzymanymi przy zastosowaniu transformaty Fouriera (Fast Fourier Transform).
This paper discusses the problems connected with frequency analysis and multiple signal classification (MUSIC) of disturbances that can accompany the measurements of partial discharges in industrial conditions using the acoustic emission method. It presents different kinds of interfering signals that can deform the measured acoustic emission signals generated by partial discharges in electric power devices. In addition, it includes the results of the measurements and frequency and MUSIC analyses of interfering signals in the form of power density spectra and of pseudo-spectrum.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 12; 79-83
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Clustering Methods for the Identification of Acoustic Emission Signals Generated by the Selected Form of Partial Discharge in Oil-Paper Insulation
Autorzy:
Borucki, S.
Łuczak, J.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/177657.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission method
acoustic signals
partial discharges
insulation
power transformer
Opis:
The article presents the results concerning the use of clustering methods to identify signals of acoustic emission (AE) generated by partial discharge (PD) in oil-paper insulation. The conducted testing featured qualitative analysis of the following clustering methods: single linkage, complete linkage, average linkage, centroid linkage and Ward linkage. The purpose of the analysis was to search the tested series of AE signal measurements, deriving from three various PD forms, for elements of grouping (clusters), which are most similar to one another and maximally different than in other groups in terms of a specific feature or adopted criteria. Then, the conducted clustering was used as a basis for attempting to assess the effectiveness of identification of particular PD forms that modelled exemplary defects of the power transformer’s oil-paper insulation system. The relevant analyses and simulations were conducted using the Matlab estimation environment and the clustering procedures available in it. The conducted tests featured analyses of the results of the series of measurements of acoustic emissions generated by the basic PD forms, which were obtained in laboratory conditions using spark gap systems that modelled the defects of the power transformer’s oil-paper insulation.
Źródło:
Archives of Acoustics; 2018, 43, 2; 207-215
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Application of Selected Hierarchical Clustering Methods for Classification the Acoustic Emission Signals Generated by Partial Discharges
Autorzy:
Borucki, Sebastian
Łuczak, Jacek
Lorenc, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2097707.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
acoustic emission method
acoustic signals
partial discharges
power transformer
clustering method
Opis:
The paper presents the results of the application of the hierarchical clustering methods for the classification of the acoustic emission (AE) signals generated by eight basic forms of partial discharges (PD), which can occur in paper-oil insulation of power transformers. Based on the registered AE signals from the particular PD forms, using a frequency descriptor in the form of the power spectral density (PSD) of the signal, their representation in the form of the set of points on plane XY was created. Next, these sets were subjected to analysis using research algorithms consisting of selected clustering methods. Based on the suggested numeric performance indicators, the analysis of the degree of reproduction of the actual distribution of points showing the particular time waveforms of the AE signals from eight adopted PD forms (PD classes) in the obtained clusters was carried out. As a result of the analyses carried out, the clustering algorithms of the highest effectiveness in the identification of all eight PD classes, classified simultaneously, where indicated. Within the research carried out, an attempt to draw general conclusions as to the selection of the most effective hierarchical clustering method studied and the similarity function to be used for classification of the selected basic PD forms.
Źródło:
Archives of Acoustics; 2021, 46, 3; 409-417
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Complex Measurement System for Enhancement of Capability for Marine Engines Diagnostics
Autorzy:
Charchalis, A.
Powiązania:
https://bibliotekanauki.pl/articles/116855.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Morski w Gdyni. Wydział Nawigacyjny
Tematy:
Marine Engines Diagnostics
Complex Measurement System
Exploitation Decision Aid System
marine diesel engine
mechanical engineering
Technical Diagnostic Laboratory
Vibroacoustics
Acoustic Emission Measurement Method
Opis:
Modern way of machines’ exploitation, due to their high level of structural complication, requires proper level of supervising. That supervising is generally based on detection of pre-failure states and evaluation of machines’ single elements or components condition. In the frame of development of the research capacity of the Mechanical Faculty of Maritime Academy in Gdynia, has been developed the Exploitation Decision Aid System for marine engines exploitation. The system was based on existing test bed with the marine diesel engine Sulzer AL 25/30 as a core element. Modernization of the measurement equipment, significantly extended research capacity, what resulted with improvement of quality, extension of the span, and acceleration of conducted research and development works in the domain of safety of exploitation and diagnostics of marine power plants. Investments in modern measurement apparatus enables also an extension of the range of research and expertise related to engines’ failures and pollutants emission, in relation to broad spectrum of implemented fuels. The goal has been achieved in way of modernization of engine’s monitoring system and stands in Technical Diagnostic Laboratory.
Źródło:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation; 2013, 7, 3; 415-420
2083-6473
2083-6481
Pojawia się w:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza czasowo-częstotliwościowa sygnałów emisji akustycznej generowanych przez podobciążeniowy przełącznik zaczepów o konstrukcji z osobnym wybierakiem i przełącznikiem mocy
Time-frequency analysis of acoustic emission signals generated by on load tap changer constructed from separated selector and power switch
Autorzy:
Cichoń, A.
Frącz, P.
Lorenc., M.
Powiązania:
https://bibliotekanauki.pl/articles/153883.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
podobciążeniowe przełączniki zaczepów (PPZ)
diagnostyka transformatorów elektroenergetycznych
metoda emisji akustycznej
on load tap changer (OLTC)
electric power transformer diagnosis
acoustic emission method
Opis:
Podobciążeniowe przełączniki zaczepów (PPZ) są jednym z głównych elementów transformatora, który zapewnia możliwość regulacji napięcia w sieci elektroenergetycznej. Ich awarie są częstą przyczyną wyłączeń transformatorów rozdzielczych. W artykule przedstawiono wyniki prac naukowo-badawczych mających na celu scharakteryzowanie sygnałów emisji akustycznej (EA) generowanych przez PPZ o konstrukcji z osobnym wybierakiem i przełącznikiem mocy. Zaletą metody EA jest możliwość wykonywania pomiarów w warunkach normalnej pracy urządzenia. Badania przeprowadzono w warunkach laboratoryjnych. Analizę sygnałów EA przeprowadzono w dziedzinie czasu i czasowo-częstotliwościowej. Ocenę składowych czasowo-częstotliwościowych przeprowadzono z wykorzystaniem krótkoczasowej transformaty Fouriera (STFT) i ciągłej (CWT) transformaty falkowej.
An important part of an electric power transformer is the on load tap changer (OLTC) which enables voltage regulation in the network. Due to high level of failure frequency of these devices, it is necessarily to look for new diagnostic methods which enable their technical state estimation under transformer normal operating conditions. Presently at the Electric Power Institute of the Opole University of Technology there are works in progress aspiring to determine the application possibility of the AE method for OLTC diagnosis. Results of the research works aiming at characterizing the acoustic emission (AE) signals generated by the OLTC constructed from a separated selector and a power switch are presented in the paper. Measurements were taken in a setup with a model of the OLTC type VEL - 110 - 27 from ELIN as the main element. AE signals generated during the whole OLTC joining cycle are presented. Within the signal there were enhanced four characteristic acoustic structures which regard to succeeding stages of the joining process. The AE signals generated by the selector and power switch were analyzed in detail. The analysis of time-frequency components of the signals generated by the OLTC was carried out with the short time Fourier transform (STFT) and con-tinuous wavelet transform (CWT). Based on the comparison of the AE signals generated by the power changer and the selector, two measuring paths endowed with wide band contact transducers were proposed for practical application.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 360-363
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza wyników badań w zakresie oceny stopnia zużycia styków PPZ metodą akustyczną i oscylograficzną
Comparison analysis of research results on determining level of OLTC contact deterioration using acoustic and oscillographic methods of diagnostics
Autorzy:
Cichoń, A.
Bergber, P.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/152504.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
podobciążeniowe przełączniki zaczepów (PPZ)
diagnostyka transformatorów elektroenergetycznych
metoda emisji akustycznej
on load tap changer (OLTC)
electric power transformer diagnostics
acoustic emission method
Opis:
W artykule przedstawiono wyniki prac naukowo – badawczych związanych z diagnostyką podobciążeniowych przełączników zaczepów (PPZ). Badania wykonano w warunkach laboratoryjnych z wykorzystaniem modelu fizycznego PPZ typu VEL 110, umieszczonego w kadzi wypełnionej olejem izolacyjnym. Sygnały emisji akustycznej rejestrowano szerokopasmowym przetwornikiem piezoelektrycznym przymocowanym do zewnętrznej części kadzi. Zarejestrowane sygnały poddano analizie w dziedzinie czasowej. Wyniki pomiarów metodą oscylograficzną przedstawiono w postaci przebiegów prądowych i wyznaczając wartości czasów własnych. Na podstawie uzyskanych wyników przeprowadzono analizę porównawczą wyników uzyskanych za pomocą obu metod pomiarowych.
This paper presents results of scientific research on diagnostic methods for on load tap changers (OLTC). Measurements were made in laboratory conditions with use of a physical model of the VEL 110 OLTC placed in a tank filled with insulating oil. Acoustic emission signals were recorded with use of a R15α wide band piezoelectric transducer which was fixed to the tank of the model. These signals were analyzed in the time domain, which resulted in calculation of the signal envelope and its characteristic times. The results of the oscillographic measurements are presented in the form of current diagrams and the calculated OLTC characteristic times. Basing on the obtained results of the oscillographic and acoustic measurements, a comparison analysis of both diagnostic methods was performed. The research data presented in this paper proves that detection of OLTC contact deterioration is possible by using both oscillographic and acoustic methods of diagnostics.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 152-155
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnosis of the Non-Concurrent Operation of the On-Load Tap Changer Contacts by the Acoustic Emission Method
Autorzy:
Cichoń, A.
Borucki, S.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/177044.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power transformer
on-load tap changers
acoustic emission method
Opis:
On-load tap changers (OLTC) are some of the main transformer elements that make voltage adjustment in a power network possible. Their failures often cause shutdowns of distribution transformers. The paper presents research work aimed at the assessment of the technical condition of OLTCs by the acoustic emission method (EA). This method makes the OLTC diagnosis possible without the need of disconnecting the transformer from the system. The measurements were taken in laboratory conditions. The influence on the operation non-concurrence of the power tap changer contacts on the AE registered signals has been investigated. The signals registered were subjected to analyses in the time and time-frequency domains. The result analysis in the time domain was carried out using the Hilbert transform and calculating characteristic times for the particular runs. A short-time Fourier transform was used for the assessment of results in the time-frequency do- main.
Źródło:
Archives of Acoustics; 2011, 36, 4; 823-830
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości wykorzystania sygnałów emisji akustycznej do detekcji wyładowań niezupełnych w izolatorach przepustowych
Application possibility estimation of acoustic emission signals for detection of partial discharges in bushing isolators
Autorzy:
Cichoń, A.
Borucki, S.
Subocz, J.
Powiązania:
https://bibliotekanauki.pl/articles/153875.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
izolatory przepustowe
wyładowania niezupełne
metoda emisji akustycznej
diagnostyka elektroenergetyczna
bushing isolator
partial discharges
acoustic emission method
electric power diagnosis
Opis:
W artykule przedstawiono wyniki prac naukowo - badawczych związanych z detekcją wyładowań niezupełnych (WNZ) w izolatorach przepustowych z wykorzystaniem metody emisji akustycznej (EA). Badania przeprowadzono w warunkach laboratoryjnych wykorzystując model izolatora typu GSKTFK, w którym osłonę porcelanową zastąpiono obudową wykonaną z tworzywa sztucznego. Pomiary wykonywano w układach modelujących różne rodzaje uszkodzeń. Sygnały EA rejestrowano za pomocą piezoelektrycznego przetwornika stykowego przymocowanego do zewnętrznej części osłony izolatora. Analizę zarejestrowanych sygnałów przeprowadzono w dziedzinie czasowo - częstotliwościowej z wykorzystaniem krótkoczasowej transformaty Fouriera (STFT). Efektem przeprowadzonych prac było określenie możliwości wykorzystania metody EA do detekcji WNZ powstających na skutek różnych rodzajów defektów w izolacji papierowo - olejowej.
Reliable operation of an electric power system is connected with the necessity of maintenance of its particular elements for theirs good technical state. Important part of the electric power network is the high power transformer, which inherent elements are bushing isolators. Effective detection of PDs in inner part of the paper-oil isolation is one of the main conditions which assure safety operation of bushing isolators. Limited possibility for switching off the electric power devices is a reason for looking for new diagnostic methods enabling on-line measurements execution. Measurements results of AE signals generated in a bushing isolator: with defective inner paper-oil isolation, with presence of air blebs freely moving inside the isolation system, with forced motion of air blebs and with entered natural aging products of cellulose between the particular layers of the insulating system are presented in the paper. Results achieved in the scope of works performed confirmed the application possibility of AE method for technical state diagnosis of paper-oil insulation of bushing isolators in terms of PD appearance. During measurements of AE signals two kinds of PDs have been observed: electrical discharges in the inner part of paper-oil isolation and inside the air blebs. Time-frequency analysis has enabled to assign characteristic frequency bands to the particular PD types. This has created a basis for further works aiming development of research methodic enabling for AE signals measurement on bushing isolators under normal operation condition.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 348-351
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Acoustic emission signals associated with prebreakdown state in air high voltage insulating systems
Autorzy:
Dobrzycki, A.
Opydo, W.
Zakrzewski, S.
Powiązania:
https://bibliotekanauki.pl/articles/97311.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
high voltage insulating system
breakdown voltage
acoustic emission method
dielectric coatings
Opis:
The paper presents the method of acoustic emission (AE) in the study of the state of insulation systems with air as the high-voltage insulation. The tested object was a planar system of electrodes made of aluminum. In addition, the analysis of AE signals and the impact on these signals the presence of dielectric coating on the electrode surfaces of aluminum was tested. We examined the influence of saturation (seal) these coatings on the dielectric strength of the insulation system. The study was conducted at an air pressure values 1·105, 3·105 and 5·105 Pa. The strength of the electrical systems were tested at alternating voltage with a frequency of 50 Hz. Noted pros and cons of using the method of EA in the context of the assessment of high-voltage electric insulation devices. The presented results confirm the possibility of using acoustic emission method, not only for identifying vulnerable areas, but also to predict the time of of further use of high voltage device.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 278-286
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Study of Identifying Emission Sources of Acoustic Signals on the Cylinder Body of a Two-Stroke Marine Diesel Engine
Autorzy:
Dong, Xuan Thin
Nguyen, Manh Hung
Powiązania:
https://bibliotekanauki.pl/articles/1953513.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
acoustic emission
two-stroke marine diesel engine
experimental method
low-to-high frequency ranges
medium-to-high frequency ranges
vibration
Opis:
In this paper, an experimental method was utilized to investigate acoustic emission (AE) characteristics and to identify emission sources of the nonlinear AE signal on the cylinder body of a large low-speed two-stroke marine diesel engine in real-working conditions on the sea in misfiring and normal firing modes. Measurements focused on the AE signal acquired in a transverse direction in low-frequency (20-80 kHz), medium-frequency (100-400 kHz) and high-frequency (400-900 kHz) ranges. The collected signals were analyzed on the crank angle and crank angle-frequency domains. The results showed that all potential sources of the nonlinear AE signal could be mapped in the low-frequency range. However, only the AE signal caused by the combustion process at around the top dead center could be well-observed in the medium-to-high-frequency range. The findings also revealed that in normal firing conditions, the AE energy radiated by friction in the down-stroke period was smaller than in the up-stroke process due to gas-sealing forces. Moreover, the AE energy in the misfiring condition was higher than in the normal firing state. These outcomes considerably contributed understandings to characteristics of friction and wear around the mid-stroke area of the cylinder on a two-stroke marine diesel engine.
Źródło:
Archives of Acoustics; 2021, 46, 1; 105-119
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja procesu rozróżniania składników mieszaniny kamieni i bulw ziemniaka metodą emisji akustycznej
Optimization of the process involving distinguishing rock and potato tuber mix elements by the acoustic emission method
Autorzy:
Jakubowska, M.
Kukiełka, L.
Powiązania:
https://bibliotekanauki.pl/articles/287732.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
metoda emisji akustycznej
kamień
ziemniak
mieszanina
badanie rozpoznawcze
optymalizacja
acoustic emission method
rock
potato
identification tests
optimization
Opis:
Za podstawę rozróżnienia kamieni od bulw ziemniaka przyjęto różnicę poziomów natężenia dźwięku generowanego podczas ich uderzenia o stalowy element sprężysty. Przedstawiono wyniki badań rozpoznawczych (eliminujących) zrealizowanych zgodnie z planem Placketa-Burmana. Następnie przeprowadzono właściwe badania optymalizacyjne. Stosując metodę graficzną określono zbiór rozwiązań dopuszczalnych. optymalizacyjnych metody emisji akustycznej.
The parameter allowing to distinguish rocks from potato tubers is the difference in intensity level of sound generated while they strike springy steel element. The work presents the results of identification tests (elimination tests) carried out according to the Placket-Burman plan. Then, proper optimisation tests were performed. Graphic method was used to determine a set of acceptable optimising solutions for the acoustic emission method.
Źródło:
Inżynieria Rolnicza; 2006, R. 10, nr 12(87), 12(87); 189-197
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies